smart tank 2

26

Upload: godwin-esogbuzinem-iweka

Post on 08-Mar-2015

70 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Smart Tank 2
Page 2: Smart Tank 2

Fuel Storage SyStemS

a Smart way to go !

A SmartTank system is a pre-engineered fully assembled code compliant package delivered to your site for easy installation. Simply provide a concrete pad with electrical service and your ready to go. We’ll even provide pad and electrical drawings suited to your application. An environmentally friendly economical alternative.

Why Smart?

Simply stated, It’s what we would buy if we were you. We’ve selected components that we feel offer the best performance and value. Trust in our experience to provide a system to depend on. on.

Page 3: Smart Tank 2

Fuel Storage SyStemS

ContentS

Advantages– 4SizeandConfiguration– 6FlameshieldVs.FireGuard– 7FireGuard– 7FlameShield– 7Flameshield– 8FireGuard– 9TankDispensingSystemStyles– 10SystemOverview– 11SubmersiblePump– 12FSISiphonStopSystem– 13MechanicalFleetDispensingPackage– 14MechanicalRetailDispensingPackage– 15TankTrimPackages– 16TankVenting– 17MechanicalGauge– 18SiteManager– 19AviationFueling– 20FuelHouseDispenser– 22JetASystem– 23AviationFuelFiltration– 24HighCapacityAviationFuelFiltration– 25Mini-SmartTank– 26StandardEquipment– 26GasboyModel72Pump– 26

•••••••••••••••••••••••••

Page 4: Smart Tank 2

Fuel Storage SyStemS

advantageS

Factory FabricatedQuality Assurance and Control

Pre-Engineered

Exceptional Fit and Finish

Tried and True Systems

Pre - WiredElectrically Engineered

UL Listed

Fire Resistant

Corrosion Resistant

Sub Panel

E-Stop Disconnect

Keyed Lock Out

Integrated Motor Starters

Site Manager Electrical Controls

Page 5: Smart Tank 2

Fuel Storage SyStemS

Engineering Support

Site Specific

AutoCad Details

Site Plans/Designs

Concrete Details

Electrical Engineering

Installation

Plug N Play Design

Rapid Installation

No Rocket Science Required

Page 6: Smart Tank 2

Fuel Storage SyStemS

Tank CapacityConsider the following when selecting tank capacity.

CanIgetadiscountonfulltruckloadsoffuel?Whatisa“fullload”?(7-10,000gallons)Whatisyourthroughput(usage)?Howlongdoesittaketogetfueldelivered?5%islostinthetopofthetankonoverfillprevention5%islostfromthebottomasthepumpissetabovethewateranddebriszone.Isthefuelgoingtositformorethan6months?(Considerusingadditives)Codescanlimitsingletankcapacity.Variancesmustbesoughtforlargertanks.

OptionsSingle Compartment vs. Dual Compartment - You can split the tank into separate com-part-ments for multiple products. Example: A 12,000 Gallon tank with 4,000 Gallons Of-froad Diesel and 8,000 Gallons Onroad Diesel.

Dispensing Packages - A second dispensing platform can provide multiple fueling posi-tions. Two products can be dispensed on one end with a dual product dispenser. Combi-nations can be suited to need.

Internal Tank Lining - A standard tank is bare steel. A corrosion inhibiting internal lining can be installed. This option is almost always selected on Jet Fuel. A good liner is expensive as the tankis welded on the inside and the finish blasted to prepare for the application of the coating. Internal corrosion is a problem if water bottoms are not removed. A water sump-ing system is also available.

Pump Systems - We often do custom pump systems for bottom loading trucks, transferring fuel to multiple remote dispensers, etc. Please ask a sales engineer about anything spe-cial.

Fuel Management - We offer several fuel management system solutions from unattended retail credit card to fleet keys, pin numbers, buying clubs, etc. We will also pre-install a customer supplied proprietary system.

Twin Canopy Option

••••••

••

Size and ConFiguration

Page 7: Smart Tank 2

Fuel Storage SyStemS

FlameShield vS. Fire guard

Flameshield

The Flameshield tank provides adequate fire protection in most circumstances. It meets the requirements of UL 142 and SWRI 97-04. Emergency venting is designed to prevent overpressur-ization or explosion in a pool fire situation.

Fireguard

The FireGuard tank provides additional fire protection with the addition of a lightweight thermal insulation between the two walls of steel. It meets the requirements of UL 2085 and UFC 79-7. It is imperative to get an approval from the authority having jurisdiction prior to purchase or installation.

Fireguard FlameShield

Page 8: Smart Tank 2

Fuel Storage SyStemS

FlameShield

The FlameshieldTM fire-resistant aboveground storage tank is manufactured with a tight-wrap double-wall design. Standard features include tested 2-hour fire resistance, built-in secondary containment and interstitial monitoring capability.

Double wall design offers integral secondary containment which can be tested for tightness on site throughout tank life.

Interstitial space can be monitored for leak detection.

Primary storage tank and secondarycontainment compatible with a wide range of fuels and chemicals.

Built to nationally-recognized STI standards with strict third-party quality control inspection program.

Customized compartments can be provided for cost effective multi-product storage. Capacities up to 50,000 gallons.

Tested by Southwest Research Institute to SwRI 97-04 requirements for fire-resistant tank performance.

Page 9: Smart Tank 2

Fuel Storage SyStemS

Fireguard

Fireguard TM offers the safety of UL 2085 steel secondary containment- plus lightweight convenience.

Fireguard TM features a super lightweight insulation within the interstice. The porous insulation material allows migration of any liquid through the interstice to the monitoring point. Unlike plastic liners, the steel double wall design provides 110% UL-listed secondary containment. And Fireguard TM comes delivered as a complete unit with Steel Tank Institute Quality Assur-ance built in.

NowUL2085Listedusing3”oflightweightinsulationbetween2wallsofsteel.

Monitoringtubeforinterstitialleakdetection,

2-hourfireratingMeets1994UniformFireCodefor“ProtectedTank”AppendixIIF

UL2085listedfor“InsulatedSecondaryContainment-ProtectedType”ASTs

MeetsNFPA30/30Acodes(reducedseparationdistance)InnerandoutersteeltanksbuilttoUL142

ULListedSecondaryContainmentSTIlicensedandmadetoSTIqualitystandards

UFCAppendixIIFballisticsprotection

UFCAppendixIIFimpactprotectionNoexposedconcretenospallingorcracking

30-yearlimitedwarranty

Page 10: Smart Tank 2

Fuel Storage SyStemS

tank diSpenSing SyStem StyleS

Canopy and Platform

Canopy and Equipment Deck

“Econo”

Pump House

Pump Deck

“Mini”

Page 11: Smart Tank 2

Fuel Storage SyStemS

SyStem overview

Page 12: Smart Tank 2

Fuel Storage SyStemS

SubmerSible pump

Submersible pumps are known for providing years of trouble free performance. FSI prefers submersible pumps over suction pumps as pumps push liquid much better than they pull it. Submersible pumps also benefit from being liquid cooled and electrically efficient. The dependability of a submersible pump is unequaled.

SpecificationsPumpMotor:3/4H.P.Centrifugaltype.Thermallyprotected:Automaticthermaloverloadturnsmotoroffatapproximately205°F(95°C)andresetsonatapprox.115°F(45°C).LiquidCompatibility:Standardunitscompatiblewithfuelmixturescontainingupto15%ethanolormethanolwithgasolineand20%MTBE,20%ETBE,or17%TAMEwithgasoline,andalldieselandbiodieselfuelblends.100%Ethanolcompatibleversionavailable.CheckValve:23/4”(70mm)diameterconstructedofaluminumandsteelwithfluorocarbonseal.PressureReliefValve:Standardvalveissettorelievestaticlinepressureat35-50PSI(2.38to3.4bar),resealsabove20PSI(1.36bar).AirEliminator:Returnsairtotankwithonewaycheckvalvetopreventbackflow.SealElastomers:AllwettedsealsonstandardunitsuseViton®.Approvalsand/orListings:UL,CSA,BASEEFA,TUV,SAA,BKI,INMETRO,TIIS,KHK,FTZU,otherspending.QualityCertification:FEPetroisanISO9001CertifiedManufacturer.

••

Page 13: Smart Tank 2

Fuel Storage SyStemS

FSi Siphon Stop SyStem

DescriptionThe FSI Siphon Stop is a siphon prevention device used on submersible pumps for aboveground storage tanks. The system is simply designed to break a vacuum utilizing a check valve. It works in conjunction with the submersible pump “tank port” to allow air to enter the line in a negative pressure situation. It will prevent the tanks contents from siphoning through the submersible pump. Thermal expansion is relieved via the standard STP pressure relieving system. It does not effect the operation of mechanical leak de-tectors.

Page 14: Smart Tank 2

Fuel Storage SyStemS

Dresser Wayne Reliance G6200 Series Mechanical Fleet Dispensers

Keeping your fleet on the move depends on reliable, fast ac-cess to fuel. Time spent waiting for an available dispenser or struggling with slow or inefficient fueling equipment can nega-tively impact your productivity.

Dresser Wayne delivers fueling equipment you can count on to deliver consistent performance today and tomorrow.

SpecificationsPerformance:Upto22GPM(83lpm)perhoseCompatibility:Fordispensinglowviscositypetroleumfuels-diesel;biodieselblendsupto20%;gasoline,includingoxygenatedblends;kerosene;AvGas^,andjetfuel^.SeeE85option.FuelmustmeettheapplicableASTMstandard.Register:V/R10computingmechanicalregisterwithpowerresetwithinterlock.Displaysonbothsidesofcabinet.Maximumvolume999.9.Totalizer:Non-resettablesaletotalizerupto$999999.9andvolumetotalizerupto9999999.9.Displayonfrontdialface.Meter:Reliable,micro-accurate2-pistonpositivedisplacementdesign.Weights&Measuressealable.Electrical:115VAC,60Hzoperation.Motors–115/230VAC50/60Hz.InternalFilter[G]:Adapterwithten-micronfilterhelpsensureproductpurity.InletConnection:1½”(3.8cm).SatelliteConnection:Dischargeassemblyincludes1”NPT(2.5cm)internalportforsatellitepipingconnectiononremotedispensers.CabinetFinish:Extremelydurablepowder-coatedfinishgivesoutstandingappearanceandtoughness.Sides,top,bezel,andbasepaintedsilver.Doorspaintedblue(optionalblack,brown,green,red,silver,yellow,orwhite).Blackregisterface.Light[//A]:Illuminatesregisterfacesandbacklightsthetranslucentproductidpanels.Onebulbperside.Approvals:C-UL-USListed.SealablebyU.S.Weights&Measuresfortheresaleoffuel.

••

••••

meChaniCal Fleet diSpenSing paCkage

Page 15: Smart Tank 2

Fuel Storage SyStemS

Designed to deliver reliable, long-term retail fueling perfor-mance in the harshest environments, the Dresser Wayne Reli-ance G5200 Series retail fleet dispenser combines a modern durable cabinet with a dependable mechanical sales register display. Heavy duty construction, sturdy materials and time-proven components make this dispenser an excellent fit for small service stations, marinas, airports and specialized ap-plications like kerosene dispensing. It is a simple, economical solution built for years of hassle-free retail functionality.

The high grade 304 stainless steel option with a complete stain-less steel exterior cabinet including side structural columns and bases provides the added durability of stainless steel construc-tion that is especially useful in waterfront applications such as marinas.

Dresser Wayne Reliance G5200 Series Retail Mechanical Dispensers

meChaniCal retail diSpenSing paCkage

SpecificationsPerformance:Upto22GPM(83lpm)perhose(exception:Compatibility:Fordispensinglowviscositypetroleumfuels-diesel;biodieselblendsupto20%;gasoline,includingoxygenatedblends;kerosene;AvGas^,andjetfuel^.SeeE85option.FuelmustmeettheapplicableASTMstandard.Register:V/R10computingmechanicalregisterwithpowerresetwithinterlock.Displaysonbothsidesofcabinet.Maximumsale$999.99.Maximumvolume999.9.Maximumprice$9.99.Righthandmoneywheeldisplaysintenswithindicatorlinesforeverytwocents.Totalizer:Non-resettablesaletotalizerupto$999999.9andvolumetotalizerupto9999999.9.Displayonfrontdialface.Meter:Reliable,micro-accurate2-pistonpositivedisplacementdesign.Weights&Measuressealable.Electrical:115VAC,60Hzoperation.Motors–115/230VAC50/60Hz.InternalFilter[G]:Adapterwithten-micronfilterhelpsensureproductpurity.InletConnection:1½”(3.8cm).Discharge:1”(2.5cm)with¾”reducingbushing.SolenoidValve[//W1]:1”(2.5cm)two-stagevalve.StandardonremotedispensersandTwinIsuction.Alsoprovidesslowflowcontrolforfuelcontrolsystems.WithE85option,valveissinglestage.SatelliteConnection:Dischargeassemblyincludes1”NPT(2.5cm)internalportforsatellitepipingconnectiononremotedispensers.CabinetFinish:Extremelydurablepowder-coatedfinishgivesoutstandingappearanceandtoughness.Sides,top,bezel,andbasepaintedsilver.CabinetConstruction:Allpanelsarefabricatedfromheavygaugegalvannealedsteel.14-gaugesidepanelsand18-gaugedoors.G90internalbracketsandshelves.Light[//A]:Illuminatesregisterfacesandbacklightsthetranslucentproductidpanels(specifyproduct(s)withorder).Onebulbperside.Approvals:C-UL-USListed.SealablebyU.S.Weights&Measuresfortheresaleoffuel.

••

•••••

Page 16: Smart Tank 2

Fuel Storage SyStemS

High Capacity Remote Fill Package

200GPM

3”StainlessPiping

SpecificationsRemoteFillContainer:15Galloncapacity,12ga.steelconstruction,fuelresistantepoxypowdercoatfinish.drainwithlockingballvalve,ULListed.TruckAdaptor:3”KamlockAluminumPartACouplerwithDustPlugwithcolorcodedAPIcompliantproductlabel.BallValve:3”CarbonSteelBody,StainlessBall,TeflonSeals,Locking,ULListed.CheckValve:CastIron,ULListed.OverfillPreventionValve:3”Aluminum,200GPMRatedCapacity,Activatesat95%TankCapacitywithanti-splashaluminumdroptube-speciallymountedtoa6”StainlessSteelFlangewith3”rollgrovednipple,allowsforlowprofilepipingeasyremoval,serviceorinspection.Piping:3”304LStainlessSteelwithVictualiccouplingsandfittings.TankFitting:6”StainlessSteelFlange

••

tank trim paCkageS

Page 17: Smart Tank 2

Fuel Storage SyStemS

tank venting

Each tank needs an atmospheric vent and an emergency vent. Dual wall tanks require two emergen-cy vents; one for the primary tank and one for the secondary tank. The secondary emergencyvent is sized to match the primary emergency vent.

Definitions

Atmospheric Tank — A storage tank that has been designed to operate at pressures from atmosphericthrough 1.0 PSIG (760 mm Hg through 812 mm Hg) measured at the top of the tank (NFPA30 Pg. 30-8). Pressure not to exceed 1.0 PSIG under normal operation, and 2.5 PSIG under emergencyconditions (PEI RP-200).

Emergency Venting — Emergency Vent (pressure relief only) used on Aboveground Storage Tanks,as a code requirement, to help prevent the tank from becoming over-pressurized and rupturing ifexposed to fire. UL Listed.

Pressure Relieving Devices — Defined in NFPA 30 2-3.6.4, where entire dependence for emergencyrelief is placed upon pressure relieving devices, the total venting capacity of both normal andemergency vents shall be enough to prevent rupture of the shell or bottom of the tank if vertical, orof the shell or heads if horizontal.

Atmospheric Vents - Two types of atmospheric vents are used. Diesel fuel and oils use an openatmospheric vent. Gasoline uses a pressure/vacuum vent. Pressure/vacuum vents serve multiplepurposes including reducing vapor loss and enabling vapor recovery systems .

Stage 1 Vapor Recovery - A connection to the tank top used by fuel delivery trucks during a fuel deliv-ery for capturing the vapors, essentially swapping air spaces. Primarily used on class 1 liquids, such as gasoline or Avgas.

Page 18: Smart Tank 2

Fuel Storage SyStemS

meChaniCal gauge

The Morrison Fig. 818 Clock Gauge is used for measuring liquid level in aboveground storage tanks. Readout format is on a standard 12 hour clock face. Small hand represents feet and the large hand inches. Gauge can be read up to 20-30 ft. away to within 1/8”. Maximum measure-ment capability is 12 feet. The gauge can be rotated 3600 after mounting. The standard float will pass through a 2” opening.

SpecificationsBody:Aluminumwith2”NPTConnectionFloat:StainlessSteelCable:StainlessSteelOptionalHighLevelAlarm

••••

Page 19: Smart Tank 2

Fuel Storage SyStemS

Site manager

Designed specifically for the SmartTank System in compliance with the National ElectricCode, NFPA and UFC. System includes branch circuit panel board, pump motor starter, disconnect relays, pump running indicator, panel disconnect, with maintained mushroom headpush button, optional area light H-O-A and photocell (not shown). Shipped loose and installed 20-100 feet away from tank.

Specifications

Enclosure: NEMA 4X FiberglassPower Requirements: 30 amp 240V Single PhaseAll components are UL listed.Disconnects all fueling system circuits per NFPA 70 -514

Factory Pre-Wired OptionOptional factory pre-wired using premium quality mineral in-sulated, flexible, fire rated, UL Listed cable. A junction box pro-vides connection to user supplied conduit between the tank and the tank controller. Color coded connections eliminate guess work. Note: Communication wiring to fuel management and or leak detection and level monitoring systems require additional conduits to tank.

Page 20: Smart Tank 2

Fuel Storage SyStemS

Project Photos

Qualifications and ExperienceFitzsimmons Systems Inc. (FSI) is a privately held petroleum equipment manufacturer and distributor based in Syracuse, NY. The company has achieved a record of steady growth since 1998. Since incep-tion, FSI has been awarded and successfully performed numerous commercial, and military aviation fueling system contracts throughout the United States and abroad.

FSI’s most current projects include the design and installation of a Jet A fuel farm for Rolls-Royce at NASA’s Stennis Space Center. FSI was also awarded a second phase contract to provide an integrated pumping/filtration/fuel quality monitoring system. FSI’s corporate experience also includes hundreds of small to medium scale projects for FBO’s, municipal airports, private aviation, military and others. FSI has the ability to integrate and respond to the schedules, interfaces and demands of complex projects in a coordinated and responsive manner. The experience of the FSI team provides a strong capability to support new customer efforts.

aviation Fueling Project Photos

Page 21: Smart Tank 2

Fuel Storage SyStemS

Project Photos

Page 22: Smart Tank 2

Fuel Storage SyStemS

FuelhouSe diSpenSer

35/60/80GPMConfigurations

1”,1½”or2”InternalHoseReelOptions

ElectricorSpringRewind

LiquidControlsPDMeter

InternalDual-elementFilters

ResaleAccurate

StainlessSteelEnclosure

CommercialorRetailElectronicDisplay

PowderCoatedFrameandFace

OptionalALLStainlessSteelConstruction

The Fuelhouse Dispenser is a versatile, high speed, reel equipped dispenser designed toward marine and aviation applications. With flow rates up to 80 gpm and various hose reel configurations available, the Fuelhouse dispenser can fill almost any requirement you have.

FH-510 series dispensers are capable of fuel delivery rates up to 35 GPM. The units contain a 1½” positive displacement rotary meter, a 1½” solenoid valve, inlet filter assembly and a 1” hose reel. The hose reel is available with capacities of 85’ and 130’. Although both reel sizes are available with electric hose re-turn, the smaller reel has the option of spring rewind. The nozzle boot can accommodate a 7H or 1290-style nozzle (contact factory for other nozzle types).

FH-515 series dispensers are capable of fuel delivery rates up to 60 GPM. The units contain a 1½” positive displacement rotary meter, a 2” solenoid valve, dual element filter assembly and a 1½” hose reel. The hose reel is available with capacities of 50’ and 100’. Although both reels sizes are available with elec-tric hose return, the smaller reel has the option of spring rewind. The nozzle boot can accommodate a 7H or 1290-style nozzle (contact factory for other nozzle types).

FH-720 series dispensers are capable of fuel delivery rates up to 80 GPM. The units contain a 2”positive displacement rotary meter, a 2” solenoid valve, dual element filter assembly and a reel for2” hose. The hose reel has a capacity of 50’ and is only available with electric rewind. The nozzleboot can accommodate a 7H or 1290-style nozzle (contact factory for other nozzle types).

Commercial electronic dispensers units are fitted with a 6 digit backlit LCD display and a nonresettable-electro-mechanical totalizer. A programmable volume pulse output is standard. Retail electronic dis-pensers calculate both volume and money. Six digit, backlit LCD displays are provided for both volume and money readouts. The price per gallon display is 4 digits and 0.5” high. The pulse output from the dispenser is programmable for either money or volume. When set for volume pulse output, the resolution is programmable for1, 10, or 100 pulses per gallon.

Page 23: Smart Tank 2

Fuel Storage SyStemS

Jet a SyStem

180GPMLoading/Unloading

60-100GPMDispensing-OverwingandUnderwing

FeaturesBlackmerGX3EPositiveDisplacementPump-SlidingVanePumpwithDuravanes15HPExplosionProofMotor3PH,230/460Volts,60HzVelcon180GPMHorizontalCoalescer/SeparatorFilterVessel

PKG-P-AV-200

w/ASME/APICertificationGammonDifferentialPresureGauge3”AluminumFloatingSuctionSystem150GPMPositiveDisplacementMeterElectronicorMechanicalRegister3”StainlessSteelPiping3in.FillStrainer/Adaptor(4)TwoPosition3in.ButterflyValveWithOGasketCheckValve3in.WithTGasketFireValve-3”Flg3inFloatingSuctionAssywithretrievecable/capAnti-SiphonVacBrkSolenoid.25”Vic3inType304SSSched10s90degreeElbowAirEliminatorJet-AGTP2686-2SS1/2”NPTCkValvePressureReliefValve-GTP1357V3inx6inOverfillValve-ValveOnly-SizeNipplefor95percentofTankCapacity3inx10ft-AluminumDropTubeBonding/GroundingReel

••••••••••••••••••

Page 24: Smart Tank 2

Fuel Storage SyStemS

aviation Fuel Filtration

Positive Protection filters for removal of water and dirt from AvGas and Jet Fuel

PositiveWaterRemoval:Aquaconcartridgesremovefreeandemulsifiedwaterfromfuelsandoils.

PositiveWaterHolding:Filteredwaterischemicallylocked-inandcan’tbesqueezedout.

EffectiveDirtRemoval:98%+efficiencyfor1,5,or25micrometerparticles.

DescriptionPatented Aquacon® filter cartridges have a unique high capacity inner fil-ter media which removes all free and emulsified water from hydrocarbon fuels down to less than 5 ppm in the effluent. Absorbed water is chemi-cally locked into this media and cannot be squeezed out. When a car-tridge reaches its water holding capacity, its accordian pleats swell shut and block the flow. This “positive shutoff” prevents any water-laden fuel from passing downstream through the saturated cartridge. This causes an increase in the differential pressure which signals the operator to change the cartridge. Solid contaminants are removed by the cartridge’s two par-ticulate filter media layers. The pleated accordian style design provides a large surface area for maximum dirt holding capacity.Models are offered for particulate filtration down to either 5 or 1 microm-eter size with 98% plus efficiency. Performance is not affected by the pres-ence of surface active agents.

Differential Pressure GaugeWhen the needle is in the green zone of the gauge during normal flow, the differential pressure is less than 15 psid across the installed element,and the element does not need to be changed out.When the needle is in the red zone, the differential pressure is morethan 15 psid and the element should be changed out. It has reached its recommended maximum pressure differential.

Specifications:Recommendedmaximumflowrate:5to50GPMMaximumoperatingpressure:150psiMaterial:Castaluminumhead,carbonsteelshellwithepoxy-paintedexteriorandinterior,stainlesssteelclampbandInlet/Outletconnection:1-1/2”FPTInlet/Outletface-to-face:7-1/2”ClosureSeal:VitonHeight:19”withdraincockWeight:10lbs.Hardwareincluded:Buna-Nlidgasket1/8”brasspetcockventvalveand1/2”draincock

•••

••••••

Page 25: Smart Tank 2

Fuel Storage SyStemS

high CapaCity aviation Fuel Filtration

JET-A HV-1633150 FILTER / SEPARATOR / COALESCER.

SpecificationsRatedat240GPM.GammonPressureDifferentialGauge,0–150PSIpressuregaugewithsnubber,Inlet/OutletMilliporesamplingports,Stainlesssteelaireliminator,flowcheckvalve,manualaireliminatorandpressurereliefvalveareplumbedbacktostorageeliminatingallvapors,Automaticthermostaticallycontrolledheatedsump,(Jet-A)Automaticwaterdetectionwithalarmandpumpmotorshutdown,(Jet-A)Fail-safemanualsumpdrain.

•••••

Page 26: Smart Tank 2

Fuel Storage SyStemS

Features & BenefitsPre-EngineeredPackageCodeCompliantEasyInstallation30YearWarrantyEconomicalConsistentQualityDualWallFireRatedTankElectronicDispenserTopMountFillwithContainmentAlarmClockMechanicalGaugeLeakMonitorOverfillPreventionValveEmergencyVentingDecals

••••••

•••••••

mini-Smarttank

The “Rolls Royce” in small fuel systems.

300-1500 Gallon ModelsThe Mini SmartTank system is a pre-engineered fully assembled code compliant package de-livered to your site for easy installation. Simply provide a concrete pad with electrical service and your ready to go. We’ll even provide pad and electrical drawings suited to your applica-tion. An environmentally friendly economical alternative.

Standard equipment

gaSboy model 72 pump

SpecificationsDELIVERYRATE-Upto18GPMREGISTER-4-wheelpush-buttonreset.Includes7-digitmastertotalizer.METER-Nutatingdiscphenolicmeasuringchamberinaluminumdiecasthousing.Adjustablecalibration+/-.5%atfullflow.PUMPINGUNIT-Self-priming,directdriverotaryvane.23PSI(1.6bars)stainlesssteelbypassvalve.Checkvalvewithpressurereliefvalve.STRAINER-100meshnylon.MOTORANDPOWERREQUIUMENTS-Explosion-proof,1/3HP,1725RPM,115VAC,60HzmotorwiththermaloverloadprotectionandauxiliaryACline.Vacuumbreakerlocatedinthedischargecastingtopreventaccidentalsiphoningwhenthenozzleisopenandlowerthantheproductlevel.

••

••