SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors P.10 To satisfy the diverse needs of our valued clientele, we at SUNX have a very wide variety of sensors to choose from. So many are available that customers often complain about their labor-intensive search for the right sensor in our product lineup. This guide was put together in order to help system designers save time when making a selection. 5. Fiber Selection P.38

Upload: others

Post on 30-Sep-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SENSOR SELECTION GUIDE - D.A.S. Distribution · SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors

SENSOR SELECTION GUIDE

1. Selecting by application

2. Photoelectric Sensors P.4

3. Inductive Proximity Sensors P.8

4. Pressure Sensors P.10

To satisfy the diverse needs of our valued clientele, we at SUNX have a very wide variety of sensors to choose from. So many are available that customers often complain about their labor-intensive search for the right sensor in our product lineup. This guide was put together in order to help system designers save time when making a selection.

5. Fiber Selection P.38

Page 2: SENSOR SELECTION GUIDE - D.A.S. Distribution · SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors

2. Photoelectric sensors

3098.425

1032.808

1239.370

1239.370

1032.808

1032.808

1032.808

2.58.202

26.562

26.562

26.562

13.281

13.281

0.51.640

0.51.640

0.51.640

0.30.984

0.150.492

0.10.328

0.05 0.164 (fixed)

0.005 0.016 (fixed)

50164.042

Thru-beam type In this selection guide, an illustration of a representative model type is shown for each series of the general use sensors.

RX-M50

NX5-M30A

CY-21

CY-11A

NX5-M10RA

VF-M10T

RX-M10

CX-411

SH-61R

EX-23

RX-M2R

SH-33R

EX-21A

EX-19A

RX-500G

EX-13A

EX-31A

SH-21

EX-11A

SH-31G

RT-610-50

PM-K54

43

35

56

71

35

75

35

20

21

10.5

35

12.5

4.5

3.5

35

3.5

14

3

3.5

12.5

85

7

1.693

1.378

2.205

2.795

1.378

2.953

1.378

0.787

0.827

0.413

1.378

0.492

0.177

0.138

1.378

0.138

0.551

0.118

0.138

0.492

3.346

0.276

0.551

0.709

0.709

1.024

0.551

0.433

21

0.323

0.551

0.252

0.630

0.394

0.551

0.394

0.614

0.315

0.394

0.252

0.866

1.000

1.378

2.441

2.441

2.165

1.378

1.220

"21

0.748

1.378

0.492

0.709

0.571

1.378

0.571

0.551

0.472

0.571

0.492

2.953

0.874

14

18

18

26

14

11

8.2

14

6.4

16

10

14

10

15.6

8

10

6.4

22

25.4

M18

M18

35

62

62

55

35

31

19

35

12.5

18

14.5

35

14.5

14

12

14.5

12.5

75

22.2

P.276

P.358

P.302

P.302

P.358

P.368

P.276

P.192

P.386

P.218

P.276

P.386

P.218

P.232

P.276

P.232

P.210

P.386

P.232

P.386

P.328

P.338

Model No. Sensingrange (m ft)

Appearance (mm in) Page

Specifications Functions

Depth Width Height

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�2-wire type RX2-M5 (5 m 16.404 ft) and IP67g (oil-resistant) RX4-M5 (5 m 16.404 ft) available

�Also available without a timer

�Applicable amplifier: SU-7�Chemical-resistant type

�Applicable amplifier: SU-7

�Aside from A typenLight-ON,B typenDark-ON also available

�Side-ON EX-13EA/13EB and operation mode switch on the bifurcation types available

�Aside from A typenLight-ON,B typenDark-ON also available

�M4 screw mounting

�Side-ON SH-21E available�Applicable amplifier: SU-7

�Aside from A typenLight-ON,B typenDark-ON also available

�Side-ON EX-11EA/11EB and operation mode switch on the bifurcation types available

�Applicable amplifier: SU-7

�Mark detection type also available

�16 other types varying in appearance available

A

A

A

A

A

S

A

A

A

A

A

S

A

S

A

A

P

A

P

P

P

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

Free

DC

Free

Free

N

N

R

R

R

R

R

R

R

R

R

R

R

G

G

I

I

I

I

I

I

I

I

I

P

P

P

P

F

PT

A

PT

PT

PT

PC

PT

A

P

Z 67

67

67

66

66

66

67Z

67

67

67

N 67Z

66

67

67

N 67Z

N 67

67Z

62

N 67

66

N 66Al

PC

PC

d

d

d

d

4

3

3

3

3

NP

NP

A

NP

NP

NP

NP

NP

NP

NP

NP

NP

"10"0.394 S

Remarks

Str

uctu

re

Powe

r sup

ply

Out

put

Emiss

ion co

lor

Case

mat

eria

l

Pro

tect

ion

Self-

diagn

osis

Tim

er

Sen

sitiv

ityad

just

er

Test

inpu

t(e

mis

sion

hal

t)

Inte

rfer

ence

prev

entio

n

Ligh

t int

ensi

tym

onito

r

5 to 24

10 to 30

AC

SENS

OR SE

LECT

ION

GUID

E

4

Page 3: SENSOR SELECTION GUIDE - D.A.S. Distribution · SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors

SENS

OR SE

LECT

ION

GUID

E

5

10 to 30

10 to 30

NX5-RM7A

NX5-PRVM5A

VF-RM5T

RX-RVM5

RX-PRVM3

CX-491

CY-27

CY-17A

CY-29

CY-19A

CX-28IR

CX-28

EX-29A

0.1 to 70.328 to 22.966

0.1 to 50.328 to 16.404

0.05 to 0.50.164 to 1.640

0.03 to 0.20.098 to 0.656

Retroreflective type In this selection guide, an illustration of a representative model type is shown for each series of the general use sensors.

Remarks marked with ‘�’ represent retroreflective types with polarized filters that enable even specular object detection.

35

35

75

39

39

20

56

71

57.5

72.5

20

20

12.3

1.378

1.378

2.953

1.535

1.535

0.787

2.205

2.795

2.264

2.854

0.787

0.787

0.484

0.709

0.709

1.024

0.551

0.551

0.433

0.472

0.472

0.323

2.441

2.441

2.165

1.378

1.378

1.220

1.220

1.220

0.866

18

18

26

14

14

11

12

12

8.2

62

62

55

35

35

31

31

31

22

P.358

P.358

P.368

P.276

P.276

P.192

P.302

P.302

P.302

P.302

P.1080

P.1080

P.218

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�Also available without a timer�VF-PRM3 with polarizing filter

also available

�2-wire type RX2-PRVM2 (2 m 6.562 ft), RX-PRV500 for transparent object detection also available

(Note) With self-diagnosis output type also available�For transparent object detection�Optimal for detecting water, alcohol and other

transparent liquids inside plastic bottles

(Note) With self-diagnosis output type also available�For transparent object detection

�Aside from A typenLight-ON,B typenDark-ON also available

A

A

A

A

A

A

A

P

A

P

P

P

P

DC

DC

DC

DC

DC

DC

DC

Free

DC

Free

Free

AC

AC

N

N

R

R

R

R

R

I

I

I

R

R

I

I

I

66

66

67

67

67

67

67

67

67

67

67

66

67

Z

P

P

P

P

P

P

PC

PC

PT

PC

Z

PC �

4

How to read the table

Appearance Supecifications Functions

P P

A

S

R

G

I

ZAl

DC

Free

P

A

N

PCAPTPAF

The number inside the ‘�’ mark represents the ‘�’ value in the IEC established protection IP�.

Equipped with a function that lets the user know when sensing conditions are unstable such as when the incident light intensity decreases.

The incident light intensity level can be verified by a digital display or by an optional sensor checker CHX-SC2 level indicator.

This function, which allows the light emission to the halted from the exterior of the sensor, can be used for the automation of start-up inspections as well as interference prevention.

This function prevents mutual interference of light even when installing two sensors next to each other.�Equipped with interference

prevention circuit�Optional filter availabledMay be applicable for

halting emissions

Equipped with OFF-delay timer (variable)Equipped with variable timer with selectable ON-delay / OFF-delay / non-delay featuresEquipped with variable timer with selectable ON-delay / OFF-delay / ONE SHOT non-delay features

WidthDepth

Height

NP

NP

NP

A

A

NP

NP

NP

(Note)

(Note)

4

3

O

Model No. Appearance (mm in) Page

Specifications Functions

Depth Width Height

Remarks

Depth: from the detection surface to the back surface (mm in)

Width: width of the detection surface (mm in)

Height: from the bottom surface to the top surface (mm in)

Infrared light

Red light

Green light

Str

uctu

re Amplifier built-in

Power supply built-in

Amplifier-separated

Pow

er s

uppl

y

DC 12 to 24 V

AC/DC

AC 24 to 240 V

Out

put NPN output

PNP output also available

Relay contact output

AC non-contact output

Emiss

ion

colo

r

Cas

e m

ater

ial

Die-cast zinc alloyDie-cast aluminumPBT resinPolycarbonate resinABS resinPolyethylene terephtharate resinPolyalylate resinFluorine resin

�With adjuster

�Multi-turn adjuster

�None

Pro

tect

ion

Sens

itivity

adjus

ter

Self-

diag

nosis

Test in

put (em

ission

halt)

Interfe

rence

preven

tion

Light

inten

sity m

onito

rT

imer

Diagnosis

0.1 to 50.328 to 16.404

0.1 to 50.328 to 16.404

0.1 to 30.328 to 9.843

0.1 to 30.328 to 9.843

39.843

39.843

1.54.921

1.54.921

0.05 to 10.164 to 3.281

Sensingrange (m ft)

M18

M18

M18

M18

Str

uctu

re

Powe

r sup

ply

Out

put

Emiss

ion co

lor

Case

mat

eria

l

Pro

tect

ion

Self-

diagn

osis

Tim

er

Sen

sitiv

ityad

just

er

Test

inpu

t(e

mis

sion

hal

t)

Inte

rfer

ence

prev

entio

n

Ligh

t int

ensi

tym

onito

r

AC

Page 4: SENSOR SELECTION GUIDE - D.A.S. Distribution · SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors

2. Photoelectric sensors

800

700

30011.811

1,000

501.969

501.969

70 to 2002.756 to 7.874

2007.874

5 to 1600.197 to 6.299

1204.724

1204.724

1003.937

10 to 700.394 to 2.756(Conv. point: 40 1.575)

20 to 350.987 to 1.378(Conv. point: 30 1.181)

5 to 380.197 to 1.496(Conv. point: 20 0.787)

45 to 1151.772 to 4.528

6 to 140.236 to 0.551(Conv. point: 10 0.394)

2.5 to 80.098 to 0.315(Conv. point: 10 0.394)

2 to 250.079 to 0.984(Conv. point: 10 0.394)

2 to 250.079 to 0.984(Conv. point: 10 0.394)

Reflective type

VF-D1000T

CX-422

RX-D700

NX5-D700A

CX-421

EX-22A

CY-22

CY-12A

EX-32A

SH-22

CX-423

RX-D200R

EX-28A

SH-32R

EX-44

EX-43T

EX-42

EX-14A

EX-24A

EX-26A

PM2-LH10

75

20

35

35

20

12.3

56

71

18

3

25

35

12.3

12.5

18

18

18

3.5

4.5

12.3

25

2.953

0.787

1.378

1.378

0.787

0.484

2.205

2.795

0.709

0.118

0.984

1.378

0.484

0.492

0.709

0.709

0.709

0.138

0.177

0.484

0.984

26

11

14

18

11

8.2

15.6

12

11

14

8.2

6.4

10

10

10

13

16

8.2

8.4

55

31

35

62

31

22

14

12

31

35

22

16.5

30

30

30

14.5

18

22

26

1.024

0.433

0.551

0.709

0.433

0.323

0.614

0.472

0.433

0.551

0.323

0.252

0.394

0.394

0.394

0.512

0.630

0.323

0.331

2.165

1.220

1.378

2.441

1.220

0.866

0.551

0.472

1.220

1.378

0.866

0.650

1.181

1.181

1.181

0.571

0.709

0.866

1.024

P.368

P.192

P.276

P.358

P.192

P.218

P.302

P.302

P.210

P.386

P.192

P.276

P.218

P.386

P.266

P.266

P.266

P.232

P.218

P.218

P.350

�Also available without a timer�500 mm 19.685 in sensing

range type also available

�2-wire type RX2-D300 (300 mm 11.811 in), 300 mm 11.811 in sensing range wide-view type also available

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�M6 screw mountable

�Applicable amplifier: SU-7

�Aside from A typenLight-ON,B typenDark-ON also available

�Applicable amplifier: SU-7

(Note) EX-43 without no timer also available (models without timer is equipped with sensitivity adjuster)

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�Aside from A typenLight-ON,B typenDark-ON also available

�5 other types varying in appearance available

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

P

P A

A

P

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

Free

Free

N

N

N

N

N

R

R

R

R

R

R

R

R

I

I

I

I

I

I

I

I

I

R

I

R

I

PC

PC

Z

PT

PC

PT

A

PA

PA

PA

PT

PT

PT

PC

66

67

67

66

67

67

67

67

67

62

67

67

67

66

67

67

67

67

67

67

Z

Z

S

S

P

P

P

P

P

4

3

3

O

NP

NP

NP

NP

NP

NP

NP

P

N

NP

N

NP

N

N

P

In this selection guide, an illustration of a representative model type is shown for each series of the general use sensors.

Model No. Sensingrange (mm in)

Appearance (mm in) Page

Specifications Functions

Depth Width Height

Remarks

Typ

eD

iffu

se r

efle

ctiv

e ty

pe

Nar

row

-vie

w r

efre

ctiv

e ty

pe

Co

nver

gen

t re

flec

tive

typ

e (Note)(Note)

39.37

31.496

27.559700

27.559S

truc

ture

Powe

r sup

ply

Out

put

Emiss

ion co

lor

Case

mat

eria

l

Pro

tect

ion

Self-

diagn

osis

Tim

er

Sen

sitiv

ityad

just

er

Test

inpu

t(e

mis

sion

hal

t)

Inte

rfer

ence

prev

entio

n

Ligh

t int

ensi

tym

onito

r

M18

M18

10 to 30

AC

SENS

OR SE

LECT

ION

GUID

E

6

Page 5: SENSOR SELECTION GUIDE - D.A.S. Distribution · SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors

SENS

OR SE

LECT

ION

GUID

E

7

DC

Free

DC 12 to 24 V

AC/DC

AC 24 to 240 VAC

How to read the table

Appearance Supecifications Functions

P P

A

S

R

G

I

ZAl

P

A

N

PCAPTPAF

The number inside the ‘�’ mark represents the ‘�’ value in the IEC established protection IP�.

Equipped with a function that lets the user know when sensing conditions are unstable such as when the incident light intensity decreases.

The incident light intensity level can be verified by a digital display or by an optional sensor checker CHX-SC2 level indicator.

This function, which allows the light emission to the halted from the exterior of the sensor, can be used for the automation of start-up inspections as well as interference prevention.

This function prevents mutual interference of light even when installing two sensors next to each other.�Equipped with interference

prevention circuit�Optional filter availabledMay be applicable for

halting emissions

Equipped with OFF-delay timer (variable)Equipped with variable timer with selectable ON-delay / OFF-delay / non-delay featuresEquipped with variable timer with selectable ON-delay / OFF-delay / ONE SHOT non-delay features

WidthDepth

Height

4

3

O

Depth: from the detection surface to the back surface (mm in)

Width: width of the detection surface (mm in)

Height: from the bottom surface to the top surface (mm in)

Infrared light

Red light

Green light

Str

uctu

re Amplifier built-in

Power supply built-in

Amplifier-separated

Pow

er s

uppl

yO

utpu

t NPN output

PNP output also available

Relay contact output

AC non-contact output

Emiss

ion

colo

r

Cas

e m

ater

ial

Die-cast zinc alloyDie-cast aluminumPBT resinPolycarbonate resinABS resinPolyethylene terephtharate resinPolyalylate resinFluorine resin

�With adjuster

�Multi-turn adjuster

�None

Pro

tect

ion

Sens

itivity

adjus

ter

Self-

diag

nosis

Test in

put (em

ission

halt)

Interfe

rence

preven

tion

Light

inten

sity m

onito

rT

imer

Diagnosis

50 to 200

1.969 to 7.874

2007.874

1003.937

401.575

Detection steps data for the convergent reflective and adjustable range • fixed-focus type sensors is available on P.12.

EQ-501T

EQ-34

RX-LS200

EQ-24

EQ-23

EQ-22

68

40

35

20

20

20

26

20

14

12

12

12

68

68

35

31

31

31

2.677

1.575

1.378

0.787

0.787

0.787

1.024

0.787

0.551

0.472

0.472

0.472

2.677

2.677

1.378

1.220

1.220

1.220

P.378

P.256

P.296

P.246

P.246

P.246

�Also available without a timer

A

A

A

A

DC

P Free

R

R

R

I 67

DC

DC

67

67

DC 67

Z

P

P

P

3

NP

NP

NP

NP

100 to 2,000

3.937 to 78.74

0.2 to 2,500

0.008 to 98.425�Two-output type also

availableA DC I PA 67

I A 67

NP

Model No. Sensingrange (mm in)

Appearance (mm in) Page

Specifications Functions

Depth Width Height

Remarks

Typ

eA

dju

stab

le r

ang

e an

d f

ixed

-fo

cus

typ

e

Str

uctu

re

Powe

r sup

ply

Out

put

Emiss

ion co

lor

Case

mat

eria

l

Pro

tect

ion

Self-

diagn

osis

Tim

er

Sen

sitiv

ityad

just

er

Test

inpu

t(e

mis

sion

hal

t)

Inte

rfer

ence

prev

entio

n

Ligh

t int

ensi

tym

onito

r

Page 6: SENSOR SELECTION GUIDE - D.A.S. Distribution · SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors

120.472

3. Inductive Proximity Sensors

Amplifier built-in type

GL-18HL

GL-18H

GXL-15FU

GXL-15HU

GL-N12F�10

GL-N12H�10

GXL-N12F

GXL-N12FT

GXL-8FU

GXL-8HU

GL-8F�10

GL-8H�10

GL-8FU�10

GL-8HU�10

GL-6F

GL-6H

GX-30MU

GX-F30MU-J

GX-N30M

GX-18MU

GX-F18MU-J

GX-N18M

GX-12MU

GX-N12M

GX-F12MU-J

GX-8MU

GX-8M

28

28

8

30

7.1

27.4

7.1

7.1

7.4

23

7.4

24.2

7.4

24.2

6

19

44.5

44.5

44.5

41.5

41.5

41.5

40.5

40.5

40.5

30

30

18

18

15

15

12

12

12

12

8

8

8

8

8

8

6

6

18

18

32

16

27.4

13

27

27

20

9.2

24

8

24

8

19

6

1.102

1.102

0.315

1.181

0.280

1.079

0.280

0.280

0.291

0.906

0.291

0.953

0.291

0.953

0.236

0.748

1.752

1.752

1.752

1.634

1.634

1.634

1.594

1.594

1.594

1.181

1.181

0.709

0.709

0.591

0.591

0.472

0.472

0.472

0.472

0.315

0.315

0.315

0.315

0.315

0.315

0.236

0.236

0.709

0.709

1.260

0.630

1.079

0.512

1.063

1.063

0.787

0.362

0.945

0.315

0.945

0.315

0.748

0.236

P.718

P.718

P.684

P.684

P.710

P.710

P.684

P.684

P.684

P.684

P.704

P.704

P.704

P.704

P.700

P.700

P.722

P.722

P.736

P.722

P.722

P.736

P.722

P.736

P.722

P.722

P.744

�8 mm 0.315 in long sensing range type also available (for non-magnetic body installation)

�Normally closed type equipped with operation indicator

�3-wire type also available(Note) The 3-wire type is equipped

with operation indicator.

�Normally closed type equipped with operation indicator

�3-wire type also available(Note) The 3-wire type is equipped

with operation indicator.

�Normally closed type equipped with operation indicator

�Spatter-resistant type

�Normally closed type equipped with operation indicator

�Spatter-resistant type

�Normally closed type equipped with operation indicator

�Spatter-resistant type

�Normally closed type equipped with operation indicator

�Without boss type GL-12F�10 also available

�Sold in sets of 10 units

�Sold in sets of 10 units

�Sold in sets of 10 units

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

DC

P

PA

P

PA

P

P

P

PA

PA

PA

PA

PA

PA

P

PA

NP

NP

NP

NP

2WN

N

N

2W

2W

N

N

2W

2W

N

2W

2W

N

2W

N

2W

2W

2WN

NP

2W

N

N

PA

g

g

g

g

g

g

g B

F

B

B

F

B

B

B

F

B

g

g

g

g

g

g

g

g

g

67

67

67

67

67

67

67

67

2

2

2

2

2

2

2

2

2

2

2

(Note)

(Note)

gStable sensing range(0 to 10 0 to 0.394)

5 0.197

5 0.197

5 0.197

(0 to 4 0 to 0.157)

(0 to 4 0 to 0.157)

(0 to 4 0 to 0.157)

4 0.157

4 0.157

(0 to 3 0 to 0.118)

(0 to 3 0 to 0.118)

3 0.118

3 0.118

(0 to 2 0 to 0.079)

(0 to 2 0 to 0.079)

2.5 0.098

2.5 0.098

(0 to 1.8 0 to 0.071)

(0 to 1.8 0 to 0.071)

2.5 0.098(0 to 1.8 0 to 0.071)

2.5 0.098(0 to 1.8 0 to 0.071)

2.5 0.098(0 to 1.8 0 to 0.071)

2.5 0.098(0 to 1.8 0 to 0.071)

1.6 0.063(0 to 1.2 0 to 0.047)

1.6 0.063(0 to 1.2 0 to 0.047)

(0 to 8 0 to 0.315)

70.276

(0 to 5.6 0 to 0.220)70.276

(0 to 5.6 0 to 0.220)70.276

(0 to 5.6 0 to 0.220)

3 0.118(0 to 2.4 0 to 0.094)

3 0.118

3 0.118

(0 to 2.4 0 to 0.094)

(0 to 2.4 0 to 0.094)

(0 to 1.6 0 to 0.063)2 0.079

Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

N

M30

M30

M30

M18

M18

M18

M12

M12

M12

M8

M8 DCB671 0.06310 to 30(0 to 0.8 0 to 0.031)

Maximum operation distance

n

Maximum operation distance

Standardmodel No.

Sensingrange (mm in)(Note)

Appearance (mm in) Page

Specification Functions

Depth Width Height Pro

tect

ion

Metal

embe

dding

Case

mat

erial

Powe

r sup

ply

Out

put

Indi

cato

r

Sensi

tivity a

djuste

r

Differ

ent fr

eque

ncy

Reve

rse ou

tput

2-w

ire ty

pe

Flex

ible

cable RemarksType

Res

in c

ase

Non

shi

elde

d ty

peTo

p sen

sing

Top s

ensin

gFro

nt se

nsing

Top s

ensin

gFro

nt se

nsing

Top s

ensin

gF

ront

sen

sing

Term

inal ty

peFro

nt se

nsing

Met

al c

ase

Shi

lded

type

Thr

eade

d ty

peTo

p sen

sing

Front

sens

ingTo

p sen

sing

Front

sens

ingTo

p sen

sing

Front

sens

ingTo

p sen

sing

(Note)

(Note)

100.394

100.394

(0 to 8 0 to 0.315)

100.394

Stable sensing range(0 to 8 0 to 0.315) n

SENS

OR SE

LECT

ION

GUID

E

8

Page 7: SENSOR SELECTION GUIDE - D.A.S. Distribution · SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors

SENS

OR SE

LECT

ION

GUID

E

9

�Applicable amplifier: GA-14 and GA-15

�Applicable amplifier: GA-14 and GA-15

�Applicable amplifier: GA-14 and GA-15

�Applicable amplifier: GA-14 and GA-15�Spatter-resistant type also

available

Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.

Note: The stable sensing range represents the sensing range for which the sensor can satisfy all the given specifications with the standard sensing object. The maximum operation distance represents the maximum distance for which the sensor can detect the standard sensing object at�20�C constant ambient temperature.Usage within the stable sensing range is recommended for accurate sensing applications.

1.50.059GX-5SU

GX-5S

GX-5M

GX-4S

GX-3S

GX-30MLU

GX-N30ML

GX-18MLU

GX-N18ML

GX-12MLU

GX-N12ML

GX-8MLU

GX-8ML

1.181

1.181

1.181

1.181

1.181

1.752

1.752

1.634

1.634

1.594

1.594

1.181

1.181

"0.213

"0.213

M0.197

"0.173

"0.150

30

30

30

30

30

44.5

44.5

41.5

41.5

40.5

40.5

30

30

"5.4

"5.4

M5

"4.4

"3.8

M30

M30

M18

M18

M12

M12

M8

M8

P.722

P.744

P.744

P.744

P.744

P.722

P.736

P.722

P.736

P.722

P.736

P.722

P.744

�Normally closed type is equipped with operation indicator.

�Normally closed type is equipped with operation indicator.

�Normally closed type is equipped with operation indicator.

�Normally closed type is equipped with operation indicator.

�Normally closed type is equipped with operation indicator.

DC

DC

DC

DC

DC

2W

N

N

N

N

g

67

67

67

67

2

2

2

2

2

d

d

d

d

g

g

g

g

g

67

g

g

(0 to 1.2 0 to 0.047)

1 0.039(0 to 0.8 0 to 0.031)

0.8 0.031(0 to 0.6 0 to 0.024)

0.8 0.031(0 to 0.6 0 to 0.024)

0.8 0.031(0 to 0.6 0 to 0.024)

220.866

(0 to 17.6 0 to 0.693)220.866

(0 to 17.6 0 to 0.693)150.591

(0 to 12 0 to 0.472)150.591

(0 to 12 0 to 0.472)

8 0.315(0 to 6.4 0 to 0.252)

8 0.315(0 to 6.4 0 to 0.252)

4 0.157(0 to 3.2 0 to 0.126)

2 0.079(0 to 1.6 0 to 0.063)

40.157

Amplifier-separated type

GH-8S

GH-5S

GH-3S

GH-2S

"8

"5.4

"3.8

"2.8

15

15

15

12

"0.315

"0.213

"0.150

"0.110

0.591

0.591

0.591

0.472

P.754

P.754

P.754

P.754

DC

DC

DC

DC

N

N

N

N

g

g

g

50

S

S

S

S

2.4 0.094(0 to 1 0 to 0.039)

1.8 0.071(0 to 0.8 0 to 0.031)

(0 to 0.6 0 to 0.024)1.2 0.047

Appearance Specifications Functions

g

50

67

IP50(IEC)IP67(IEC)IP67g(JEM)

DC

P

N

PAP

SB

F

Types with varying signal oscillation frequencies available. Close mounting possible.

Decreases your total operation costs by lowering the wiring manpower needed and consuming less than 1 mA of current.

�nTypes activated with normaly open available.

�nType with amplifier selectable normally open / normally closed.

�10-times more bending durability (compared to conventional models)Flexible cable types optimal for moving parts such as robot arms available.

2WDCB

NDCB

2WDCB

NDCB

2WDCB

B

B

B

S

S

NDCB

2WDCB

NDCB

10 to 30

10 to 30

2W

Non-threaded type

Threaded type

Rectangular head front sensingRectangular head top sensing

d

Standardmodel No.

Sensingrange (mm in)(Note)

Appearance (mm in) Page

Specification Functions

Depth Width Height Pro

tect

ion

Metal

embe

dding

Case

mat

erial

Powe

r sup

ply

Out

put

Indi

cato

r

Sensi

tivity a

djuste

r

Differ

ent fr

eque

ncy

Reve

rse ou

tput

2-w

ire ty

pe

Flex

ible

cable RemarksType

Met

al c

ase

Shi

elde

d ty

peNo

n-thre

aded

type

Non-t

hread

ed ty

peThr

eaded t

ypeT

hrea

ded

type

Non

-shi

elde

d ty

pe

Stable sensing range

Maximumoperationdistance

n

n

Standardmodel No.

Sensingrange (mm in)(Note)

Appearance (mm in) Page

Specification Functions

Depth Width Height Pro

tect

ion

Metal

embe

dding

Case

mat

erial

Powe

r sup

ply

Out

put

Indi

cato

r

Sensi

tivity a

djuste

r

Differ

ent fr

eque

ncy

Reve

rse ou

tput

2-w

ire ty

pe

Flex

ible

cable Remarks

Typ

eG

ener

al p

urpo

se

Stable sensing range(0 to 10 0 to 0.394)

Maximum operation distance

n

Width

Width

Depth

Depth

Depth

DepthHeight

Height

Diameter

Threaddiameter

Prot

ectio

n

PossiblePossible if the sensing surfaceis brought out a few mm inImpossibleMe

tal em

bedd

ing

Stainless steelBrassPBT resinPolyalylate resinBrass (fluorine resin coating)C

ase

mat

eria

l

DC 12 to 24 V

Power s

upply

Out

put NPN output

PNP output also available

DC 2-wire type output

Indi

cato

r

�2-color display

�Operation indicator

2

�Multi-turn adjuster

�None

Sensi

tivity a

djuste

r

Diff

eren

tfr

eque

ncy

Rev

erse

out

put

2-wi

re ty

peF

lexi

ble

cabl

e

How to read the table

Page 8: SENSOR SELECTION GUIDE - D.A.S. Distribution · SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors

4. Pressure Sensors

For air and non-corrosive gas

W31.6�H31.6�D38.5W1.224�H1.224�D1.516

W30�H44.7�D35W1.181�H1.760�D1.378

W30�H41�D33.5W1.181�H1.614�D1.319

W46�H69.5�D43W1.811�H2.736�D1.693

W31.6�H31.6�D38.5W1.224�H1.224�D1.516

W30�H44.7�D35W1.181�H1.760�D1.378

W30�H41�D33.5W1.181�H1.614�D1.319

W40�H20�D49W1.575�H0.787�D1.929

DP2-22

DP2-21

DP2-20

DP2-42

DP2-41

DP2-80

DP2-62

DP2-61

DP2-60

DP3-22

DP3-21

DP3-20

DP3-42

DP3-41

DP3-80

DP4-52

DP4-57

DP4-50

DP4-52P

DP4-57P

DP4-50P

DP-M2

DP-M2A

1 k

0.1 k

0.1 k

1 k

0.1 k

0.1 k

1 k

0.1 k

0.1 k

1 k

0.1 k

0.1 k

1 k

0.1 k

0.1 k

1 k

0.1 k

0.1 k

1 k

0.1 k

0.1 k

0 to 1 M

0 to 100 k

0 to �101.3 k

0 to 1 M

0 to 100 k

0 to �101.3 k

0 to 1 M

0 to 100 k

0 to �101.3 k

0 to 1 M

0 to 100 k

0 to �101.3 k

0 to 1 M

0 to 100 k

0 to �101.3 k

0 to 1 M

�100 to 100 k

0 to �101.3 k

0 to 1 M

�100 to 100 k

0 to �101.3 k

0 to 2 k

0 to 2 k

Rc(PT)

1/8femalethread

Rc(PT)

1/8femalethread

Rc(PT)

1/8femalethread

Rc(PT)

1/8femalethread

Rc(PT)

1/8femalethread

M5femalethread

M5femalethread

M5femalethread

"4.8 mm"0.945 in

pipe

P.792

P.808

P.780

Pressureport

Resolution(Pa)

Rated pressurerange (Pa)

Positivepressure

Vacuumpressure

Powersupply

Type Appearance (mm in) OutputModel No. Page

Amplifier built-in type

W40�H40�D54W1.575�H1.575�D2.126

0.01 k

0.01 k

P.822

Remarks

Dig

ital

dis

pla

y

With

aut

o-re

fere

nce

func

tion

Sta

ndar

dF

lat

IP67

Ligh

t wei

ght

Sta

ndar

dF

lat

Ligh

t wei

ght

Com

pact

Micr

o-di

ffere

ntia

lpr

essu

re

Positivepressure

Positivepressure

Vacuumpressure

Vacuumpressure

Positivepressure

Vacuumpressure

Positivepressure

Vacuumpressure

Positivepressure

Vacuumpressure

Vacuumpressure

Positivepressure

Compoundpressure

Vacuumpressure

Positivepressure

Positivepressure

Compoundpressure

�10

�15

%12

to 2

4 V

DC

�10

�15

%12

to 2

4 V

DC

�10

�15

%12

to 2

4 V

DC

�10

�15

%12

to 24

V DC

�NPN open-corrector transistor�2 outputs

�Analog voltage output (1 to 5 V)

�Easy to read LED display with 10 mm 0.394 in height letters

�Universal control is made possible thanks to its automatic sensitivity setting mode that can be set in accordance with the actual object, its dual output mode that makes one sensor perform as if it were two, and its hysteresis mode enabling hysteresis to be universally set.

�Peak hold and bottom hold displays are possible

�Analog bar display possible

�Equipped with the auto-reference function that makes the judgment level follow the original pressure fluctuations and enables the minutest of distinctions.

�Easy to read LED display with 10 mm 0.394 in height letters

�Universal control is made possible thanks to its leak test mode, optimal for air leak testing and other applications, its dual output mode that makes one sensor perform as if it were two, and its hysteresis mode enabling hysteresis to be universally set.

�Peak hold and bottom hold displays are possible

�Analog bar display possible

�Compact and optimal for panel installation

�Has an easy to read LCD display with 10 mm 0.394 in height letters and a 2-color backlight.

�Compound pressure type enabling detection from positive to vacuum pressures with a single sensor available.

�Universal control is made possible thanks to its automatic sensitivity setting mode that can be set in accordance with the actual object, its hysteresis mode enabling hysteresis to be universally set, and its forced output mode for operation checks.

�Peak hold and bottom hold displays are possible

�Analog bar display possible

�Differential pressure sensing enables the realization of high resolution of 0.01 kPa.D.

�Differential pressure sensing enables the realization of high resolution of 0.01 kPa.D.

�NPN open-corrector transistor�2 outputs

�NPN open-corrector transistor

�PNP open-corrector transistor

�NPN open-corrector transistor

�NPN open-corrector transistor�2 outputs

�Analog current output (4 to 20 mA)

DP3-60

101.3kPa

OUT2

OUT1

MODE

0-ADJ

DP3-20

101.3kPa

OUT2

OUT1

MODE

0-ADJ

MODEMODE

DP3-20

ñ101.3kPa

OUT2

OUT1

0-ADJ

MODEMODE

DP2-80

ñ101.3kPa

OUT2

OUT1

0-ADJ

MODEMODE

DP2-40

ñ101.3kPa

OUT2

OUT1

0-ADJ

MODEMODE

DP3-20

ñ101.3kPa

OUT2

OUT1

0-ADJ

DP-M2M2

M1

2OmmH

kPa0-ADJ

OUT

MODE

DOWN

MODE

UP

DP2-20

101.3kPa

OUT2

OUT1

MODE

0-ADJ

SENS

OR SE

LECT

ION

GUID

E

10

Page 9: SENSOR SELECTION GUIDE - D.A.S. Distribution · SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors

SENS

OR SE

LECT

ION

GUID

E

11

W40�H40�D54W1.575�H1.575�D2.126

PE-22

PE-21

PE-20

2.5 %

F.S.

0 to 1 M

0 to 100 k

0 to �101 k

P.832

W12.5�H20�D20W0.492�H0.787�D0.787

W12.5�H20�D25W0.492�H0.787�D0.984

W40�H20�D36W1.575�H0.787�D1.417

DPH-A00

DPH-A10

DPH-A20

DPH-A30

DPH-A02

DPH-A12

DPH-A22

DPH-A07

DPH-A17

DPH-A27

0.1 k

1 k

0.1 k

0 to 1 M

�100 to 100 k

P.764

�The industry’s first sensor head with operation indicator attached.

�Uses an intermediate connector (sensor head) great for work applications and maintenance.

�Features a highly visible 2-color digital display controller

Sensor head

Controller

DPH-A0�DPH-A30

DP5-CDP5-C-P

DPH-A2�DPH-A1�

�10

�15

%12

to 2

4 V

DC

For air and non-corrosive gasPressureport

Resolution(Pa)

Rated pressurerange (Pa)

Pressureport

Rated pressurerange (Pa)

Positivepressure

Vacuumpressure

Powersupply

Type Appearance (mm in) OutputModel No. Page

Amplifier built-in type

Remarks

LE

D b

ar d

isp

lay

R1/4 malethread

andM5 female

thread

Positivepressure

Vacuumpressure

�NPN open-corrector transistor

�19 LED bars and 1/2 step display make for 2.5 % F.S. display resolution capability

For air and non-corrosive gasResolution

(Pa)

Positivepressure

Negativepressure

Power Supply • OutputAppearance (mm in) Model No. Page

Head-separated type

Remarks

R (PT) 1/8 male thread

and M5female thread

NPT 1/8male thread

and 10-32 UNFfemale thread

R (PT) 1/8 male thread

and M5female thread

NPT 1/8male thread

and 10-32 UNFfemale thread

10-32UNF

male thread

NPT 1/8male thread

and 10-32 UNFfemale thread

M5male

thread

M5male

thread

M5male

thread

Vacuumpressure

Positivepressure

Compoundpressure

0 to�101.3 k

�12 to 24 V DC %�Analog voltage output

(1 to 5 V)

Sensor head

Controller

�10�15

�12 to 24 V DC %�NPN open-corrector

transistor (DP5-C)PNP open-corrector transistor (DP5-C-P)

�Analog voltage output(1 to 5 V)

�10�15

R (PT) 1/8 male thread

and M5female thread

DOWN

MODE

UP

DP5OUT1

OUT2

Page 10: SENSOR SELECTION GUIDE - D.A.S. Distribution · SENSOR SELECTION GUIDE 1. Selecting by application 2. Photoelectric Sensors P.4 3. Inductive Proximity Sensors P.8 4. Pressure Sensors

Detection steps data for the convergent reflective and adjustable range • fixed-focus type sensors (example)

�The illustration below shows the height necessary for each type of convergent reflective and adjustable range • fixed-focus type sensor to detect a "20 mm "0.787 in cylinder made of white non-glossy paper placed on a sheet of the same material.

20 to 35 mm0.787 to 1.378 in

Sensing range (catalog specs)

Distance between the sensing surface and the top surface of the cylinder

Emission colorRed beam type for a red circle mark and infrared beam type for no mark.

Detection stepsExample based on sensing range and hysteresis.

EX-43

PM2-LH10 (B)

0.5 to 1.6 mm0.020 to 0.063 in

0.9 to 2.1 mm0.035 to 0.083 in

0.3 to 3.75 mm0.012 to 0.148 in

0.3 to 3.75 mm0.012 to 0.148 in

1.0 to 2.0 mm0.039 to 0.079 in

2.0 to 3.5 mm0.079 to 0.138 in

1.5 to 5.0 mm0.059 to 0.197 in

0.75 to 6.0 mm0.030 to 0.236 in

1.5 to 12.0 mm0.059 to 0.472 in

5.0 to 20.0 mm0.197 to 0.787 in

6.0 to 40.0 mm0.236 to 1.575 in

20.0 to 200.0 mm0.787 to 7.874 in

2.0 to 3.5 mm0.079 to 0.138 in

EX-26A EX-24A EX-14A EQ-22 EX-43

PM2-LF10 (B)

PM2-LL10 (B)

EX-26B EX-24B EX-14B EX-43T

EQ-23 EX-42 EX-44 RX-LS200 EQ-24 EQ-34

20.0 to 250.0 mm0.787 to 9.843 in

EQ-501

EX43TModel No.

Note: The detection step varies depending on the sensing object’s color and gloss.

2.5 to 8 mm0.098 to 0.315 in

6 to 14 mm0.236 to 0.551 in

2 to 25 mm0.079 to 0.984 in

2 to 25 mm0.079 to 0.984 in

20 to 40 mm0.787 to 1.575 in 20 to 35 mm

0.787 to 1.378 in

30 to 100 mm1.181 to 3.937 in

5 to 38 mm0.197 to 1.496 in

10 to 70 mm0.394 to 2.756 in

50 to 200 mm1.969 to 7.874 in

30 to 200 mm1.181 to 7.874 in

200 to 2,000 mm7.874 to 78.740 in

200 to 2,500 mm7.874 to 98.425 in