rws300b evaluation data 型式データ · 2020-07-08 · 2.15 emi特性 electro-magnetic...

26
RWS300B EVALUATION DATA 型式データ TDK-Lambda A261-53-01D

Upload: others

Post on 16-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

RWS300B

EVALUATION DATA

型式データ

TDK-Lambda A261-53-01D

RWS300BINDEX

1. 測定方法 Evaluation Method PAGE1.1 測定回路 Circuit used for determination

測定回路1 Circuit 1 used for determination .............................................................................................................T-1静特性 Steady state data通電ドリフト特性 Warm up voltage drift characteristics出力保持時間特性 Hold up time characteristics出力立ち上がり特性 Output rise characteristics出力立ち下がり特性 Output fall characteristics過電流保護特性 Over current protection (OCP) characteristics過電圧保護特性 Over voltage protection (OVP) characteristics入力電圧瞬停特性 Response to brown out characteristics入力電流波形 Input current waveform

測定回路2 Circuit 2 used for determination ..............................................................................................................................T-1過渡応答(負荷急変)特性 Dynamic load response characteristics

測定回路3 Circuit 3 used for determination .....................................................................................................................T-2入力サージ電流(突入電流)波形 Inrush current waveform

測定回路4 Circuit 4 used for determination .....................................................................................................................T-2リーク電流特性 Leakage current characteristics

測定回路5 Circuit 5 used for determination .....................................................................................................................T-3出力リップル、ノイズ波形 Output ripple and noise waveform

測定構成 Configuration used for determination ........................................................................................................................T-3EMI特性 Electro-Magnetic Interference characteristics(a) 雑音端子電圧 (帰還ノイズ) Conducted Emission(b) 雑音電界強度 (放射ノイズ) Radiated Emission

1.2 使用測定機器 List of equipment used ....................................................................................................................................T-4

1.3 評価負荷条件 Load conditions ..........................................................................................................................................T-4

TDK-Lambda

RWS300B

2. 特性データ Characteristics

2.1 静特性 Steady state data

(1) 入力・負荷・温度変動/出力起動・遮断電圧

Regulation - line and load, Temperature drift / Start up voltage and Drop out voltage ..........................................................................................T-5

(2) リップルノイズ電圧対入力電圧

Ripple noise voltage vs. Input voltage ....................................................................................................................................T-6

(3) 効率 ・ 力率対出力電流 Efficiency and Power factor vs. Output current .......................................................................................................................................T-7

(4) 入力電力対出力電流 Input power vs. Output current ..........................................................................................................T-8

(5) 入力電流対出力電流 Input current vs. Output current ..........................................................................................................T-9

2.2 通電ドリフト特性 Warm up voltage drift characteristics ............................................................................................................T-10

2.3 出力保持時間特性 Hold up time characteristics ..................................................................................................................................T-10

2.4 出力立ち上がり特性 Output rise characteristics .............................................................................................................................................................T-11

2.5 出力立ち下がり特性 Output fall characteristics ................................................................................................................................................T-12

2.6 過電流保護特性 Over current protection (OCP) characteristics ............................................................................................................T-13

2.7 過電圧保護特性 Over voltage protection (OVP) characteristics ...................................................................................T-13

2.8 過渡応答(負荷急変)特性 Dynamic load response characteristics .................................................................................T-14

2.9 入力電圧瞬停特性 Response to brown out characteristics ..........................................................................................T-15

2.10 入力サージ電流(突入電流)波形 Inrush current waveform .........................................................................................................................................T-16

2.11 高調波成分 Input current harmonics ...............................................................................................................................................................................................T-17

2.12 入力電流波形 Input current waveform ......................................................................................................................................................................................................................T-17

2.13 リーク電流特性 Leakage current characteristics ............................................................................................................T-18

2.14 出力リップル、ノイズ波形 Output ripple and noise waveform ............................................................................T-19

2.15 EMI特性 Electro-Magnetic Interference characteristics .........................................................................................................................................................T-20~23

使用記号 Terminology used

定義 Definition

Vin ......... 入力電圧 Input voltage

Vout ......... 出力電圧 Output voltageIin ......... 入力電流 Input currentIout ......... 出力電流 Output current

Ta ......... 周囲温度 Ambient temperature

f ......... 周波数 Frequency

TDK-Lambda

RWS300B1. 測定方法   Evaluation Method1.1 測定回路   Circuit used for determination

測定回路1 Circuit 1 used for determination・静特性 Steady state data・通電ドリフト特性 Warm up voltage drift characteristics・出力保持時間特性 Hold up time characteristics・出力立ち上がり特性 Output rise characteristics・出力立ち下がり特性 Output fall characteristics・過電流保護特性 Over current protection (OCP) characteristics・過電圧保護特性 Over voltage protection (OVP) characteristics・入力電圧瞬停特性 Response to brown out characteristics・入力電流波形 Input current waveform

測定回路2 Circuit 2 used for determination・過渡応答 (負荷急変) 特性 Dynamic load response characteristics

Controlled temp. chamber

AC Powersupply

A W

V

AC

AC

P.S.

V

V

+V

-V

Shunt res.

Load

Digital power meter

SW1

Current probe

tr tf

100%95%

Output current waveformIout 50% <==> 100%

AC Powersupply

A W

V

AC

AC

P.S.

Load 1

Load 2

V

V

+V

-V

Shunt res.

Dynamic dummyload

Digital power meter

SW1

55%50%Min

TDK-Lambda T-1

RWS300B

測定回路3 Circuit 3 used for determination・入力サージ電流 (突入電流) 波形 Inrush current waveform

測定回路4 Circuit 4 used for determination・リーク電流特性 Leakage current characteristics

接地Earth

V

VV

W

Leakagecurrentmeter

AC

AC

P.S.

+V

-V

Shunt res.

Load

Digital power meter

Isolationtrans

AC AC

AC AC

AC Powersupply

FG FG

A

A W

V

AC

AC

P.S.

V

V

+V

-V

Shunt res.

Load

Digital power meter

Current probe

Slide Reg.

Dynamic dip

simulator

TDK-Lambda T-2

RWS300B

測定回路5 Circuit 5 used for determination・出力リップル、ノイズ波形 Output ripple and noise waveform

測定構成 Configuration used for determination・EMI特性 Electro-Magnetic Interference characteristics (a) 雑音端子電圧 (帰還ノイズ)

Conducted Emission

(b) 雑音電界強度 (放射ノイズ)Radiated Emission

水平大地面Horizontal ground plane

アルミ板Aluminum plate

供試機器(接地)D.U.T (Earthed) アルミ板

Aluminum plate

垂直基準大地面

(2m × 2m)Vertical groundreference plane

アンテナAntenna

EMI Test receiver spectrum analyzerpre amp.

水平大地面Horizontal ground plane

D=3m

H=80cm台Stand

入力電源AC Power supply

ターンテーブルTurn table

電源ケーブルPower cable

D=40cm擬似電源回路網AMN 50Ω/50uH

EMI Test receiverspectrum analyzer

供試機器(接地)D.U.T (Earthed)

D=80cm

H=80cm台Stand

入力電源AC Power supply

電源ケーブルPower cable

接地Earth

接地Earth

AC Powersupply

A W

V

AC

AC

P.S.

+V

-V

Load

Digital power meter

SW

R

R : 50ΩC1 : 0.1uF Film cap.C2 : 100uF Elect cap.C3 : 4700pF Ceramic cap.

Coaxial cable1.5m 50Ω

OscilloscopeBandwith : 100MHz

150mm

+

C1 C2C3

TDK-Lambda T-3

RWS300B1.2 使用測定機器  List of equipment used

EQUIPMENT USED MANUFACTURER MODEL NO.

1 DIGITAL STORAGE OSCILLOSCOPE YOKOGAWA ELECT. DL9040L / DLM2054

2 DIGITAL MULTIMETER AGILENT 34970A

3 DIGITAL POWER METER YOKOGAWA ELECT. WT110 / WT210

4 CURRENT PROBE YOKOGAWA ELECT. 701928 / 701930

5 DYNAMIC DUMMY LOAD TAKASAGO FK-600L / FK-1000L

6 DUMMY LOAD PCN RHF250 SIRIES

7 SLIDE REGULATOR MATSUNAGA S3-24100

8 ISOLATION TRANS MATSUNAGA 3WTC-50K

9 CVCF TAKASAGO AA2000XG

10 CVCF NF ES10000S

11 LEAKAGE CURRENT METER HIOKI 3156

12 DYNAMIC DIP SIMULATOR TAKAMISAWA PSA-210

13 CONTROLLED TEMP. CHAMBER ESPEC SU-641 / SH-240

14 EMI TEST RECEIVER / SPECTRUM ANALYZER ROHDE & SCHWARZ ESCI

15 PRE AMP. SONOMA 310N

16 AMN SCHWARZBECK NNLK8121

17 ANTENNA SCHWARZBECK CBL6111D

18 HARMONIC / FLICKER ANALYZER KIKUSUI KHA1000

19 SINGLE-PHASE MASTER NF 4420

20 REFERENCE IMPEDANCE NETWORK 20A NF 4150

21 MULTI OUTLET UNIT KIKUSUI OT01-KHA

1.3 評価負荷条件  Load conditions

*入力電圧が110VAC以下の場合、下記のとおり出力ディレーティングが必要です。 Output derating is needed when input voltage is 110VAC or less.

Output voltage : 5V, 12V, 24VVin Iout : Full load 5V 12V 24V

110 - 265VAC 100% 50A 25A 12.5A100VAC 92% 46A 23A 11.5A85VAC 80% 40A 20A 10.0A

TDK-Lambda T-4

RWS300B2. 特性データ Characteristics

2.1 静特性 Steady state data(1) 入力・負荷・温度変動/出力起動・遮断電圧

Regulation - line and load, Temperature drift / Start up voltage and Drop out voltage

5V 1. Regulation - line and load Condition Ta : 25 ℃Iout \ Vin 100VAC 110VAC 200VAC 265VAC Line regulation

0% 5.036V 5.036V 5.036V 5.036V 0mV50% 5.022V 5.022V 5.022V 5.022V 0mV

Full load 5.011V 5.009V 5.009V 5.009V 0mV25mV 27mV 27mV 27mV

0.500% 0.540% 0.540% 0.540%2. Temperature drift Conditions Vin : 110 VAC

Iout : Full load Ta -10℃ +25℃ +50℃ Temperature stability

Vout 5.009V 5.009V 5.005V 4mV 0.080%3. Start up voltage and Drop out voltage Conditions Ta : 25 ℃

Iout : 100 %Start up voltage (Vin) 75VACDrop out voltage (Vin) 59VAC

12V 1. Regulation - line and load Condition Ta : 25 ℃Iout \ Vin 100VAC 110VAC 200VAC 265VAC Line regulation

0% 12.027V 12.028V 12.027V 12.027V 1mV50% 12.017V 12.016V 12.017V 12.017V 1mV

Full load 12.006V 12.003V 12.003V 12.003V 0mV21mV 25mV 24mV 24mV

0.175% 0.208% 0.200% 0.200%2. Temperature drift Conditions Vin : 110 VAC

Iout : Full load Ta -10℃ +25℃ +50℃ Temperature stability

Vout 12.011V 12.003V 12.003V 8mV 0.067%3. Start up voltage and Drop out voltage Conditions Ta : 25 ℃

Iout : 100 %Start up voltage (Vin) 76VACDrop out voltage (Vin) 67VAC

24V 1. Regulation - line and load Condition Ta : 25 ℃Iout \ Vin 100VAC 110VAC 200VAC 265VAC Line regulation

0% 24.018V 24.018V 24.017V 24.017V 1mV50% 24.013V 24.013V 24.013V 24.013V 0mV

Full load 24.011V 24.009V 24.009V 24.009V 0mV7mV 9mV 8mV 8mV

0.029% 0.038% 0.033% 0.033%2. Temperature drift Conditions Vin : 110 VAC

Iout : Full load Ta -10℃ +25℃ +50℃ Temperature stability

Vout 24.042V 24.009V 24.003V 39mV 0.163%3. Start up voltage and Drop out voltage Conditions Ta : 25 ℃

Iout : 100 %Start up voltage (Vin) 76VACDrop out voltage (Vin) 62VAC

※1 Line regulation : 110VAC - 265VAC

Load regulation

Load regulation

0.000%0.000%0.000%

0.008%

Load regulation

0.008%0.000%

0.004%0.000%0.000%

※1

※1

※1

TDK-Lambda T-5

RWS300B(2) リップルノイズ電圧対入力電圧Ripple noise voltage vs. Input voltage Conditions Iout : Full load

Ta : -10 ℃25 ℃50 ℃

5V

12V

24V

0

20

40

60

80

100

120

140

50 100 150 200 250

Rip

ple

nois

e vo

ltage

(mV

)

Input voltage (VAC)

0

20

40

60

80

100

120

140

50 100 150 200 250

Rip

ple

nois

e vo

ltage

(mV

)

Input voltage (VAC)

0

20

40

60

80

100

120

140

50 100 150 200 250

Rip

ple

nois

e vo

ltage

(mV

)

Input voltage (VAC)

TDK-Lambda T-6

RWS300B(3) 効率・力率対出力電流Efficiency and Power factor vs. Output current Conditions Vin : 100 VAC

110 VAC200 VAC265 VAC

Ta : 25 ℃

5V

12V

24V

50

60

70

80

90

0 20 40 60 80 100

Effic

ienc

y (%

)

Output current (%)

0.6

0.7

0.8

0.9

1.0

0 20 40 60 80 100Po

wer

fact

orOutput current (%)

50

60

70

80

90

0 20 40 60 80 100

Effic

ienc

y (%

)

Output current (%)

0.6

0.7

0.8

0.9

1.0

0 20 40 60 80 100

Pow

er fa

ctor

Output current (%)

50

60

70

80

90

0 20 40 60 80 100

Effic

ienc

y (%

)

Output current (%)

0.6

0.7

0.8

0.9

1.0

0 20 40 60 80 100

Pow

er fa

ctor

Output current (%)

TDK-Lambda T-7

RWS300B(4) 入力電力対出力電流Input power vs. Output current Conditions Vin : 100 VAC

110 VAC200 VAC265 VAC

Ta : 25 ℃

5V

Input powerIout : 0%

100VAC 3.6W110VAC 3.6W200VAC 4.0W265VAC 4.0W

12V

Input powerIout : 0%

100VAC 3.6W110VAC 3.7W200VAC 3.9W265VAC 4.0W

24V

Input powerIout : 0%

100VAC 3.6W110VAC 3.7W200VAC 3.9W265VAC 4.1W

Vin

Vin

Vin

0

100

200

300

400

0 20 40 60 80 100

Inpu

t pow

er (W

)

Output current (%)

0

100

200

300

400

0 20 40 60 80 100

Inpu

t pow

er (W

)

Output current (%)

0

100

200

300

400

0 20 40 60 80 100

Inpu

t pow

er (W

)

Output current (%)

TDK-Lambda T-8

RWS300B(5) 入力電流対出力電流Input current vs. Output current Conditions Vin : 100 VAC

110 VAC200 VAC265 VAC

Ta : 25 ℃

5V

Input currentIout : 0%

100VAC 0.06A110VAC 0.06A200VAC 0.07A265VAC 0.08A

12V

Input currentIout : 0%

100VAC 0.05A110VAC 0.06A200VAC 0.06A265VAC 0.08A

24V

Input currentIout : 0%

100VAC 0.06A110VAC 0.06A200VAC 0.07A265VAC 0.08A

Vin

Vin

Vin

0.0

1.0

2.0

3.0

4.0

0 20 40 60 80 100

Inpu

t cur

rent

(A)

Output current (%)

0.0

1.0

2.0

3.0

4.0

0 20 40 60 80 100

Inpu

t cur

rent

(A)

Output current (%)

0.0

1.0

2.0

3.0

4.0

0 20 40 60 80 100

Inpu

t cur

rent

(A)

Output current (%)

TDK-Lambda T-9

RWS300B2.2 通電ドリフト特性 2.3 出力保持時間特性

Warm up voltage drift characteristics Hold up time characteristics

Conditions Vin : 110 VAC Conditions Vin : 110 VACIout : Full load 200 VAC

Ta : 25 ℃ Ta : 25 ℃

5V

12V

24V

-0.4

-0.2

0.0

0.2

0.4

0 1 2 3 4 5 6 7 8

Out

put v

olta

ge d

rift (

%)

Time (hours)

-0.4

-0.2

0.0

0.2

0.4

0 1 2 3 4 5 6 7 8

Out

put v

olta

ge d

rift (

%)

Time (hours)

-0.4

-0.2

0.0

0.2

0.4

0 1 2 3 4 5 6 7 8

Out

put v

olta

ge d

rift (

%)

Time (hours)

10

100

1000

0 20 40 60 80 100H

old

up ti

me

(ms)

Output current (%)

10

100

1000

0 20 40 60 80 100

Hol

d up

tim

e (m

s)

Output current (%)

10

100

1000

0 20 40 60 80 100

Hol

d up

tim

e (m

s)

Output current (%)

TDK-Lambda T-10

RWS300B2.4 出力立ち上がり特性Output rise characteristics Conditions Vin : 100 VAC (A)

110 VAC (B)200 VAC (C)265 VAC (D)

Ta : 25 ℃

5VIout : 0% Iout : Full load

2V/DIV 200ms/DIV 2V/DIV 200ms/DIV

12VIout : 0% Iout : Full load

5V/DIV 200ms/DIV 5V/DIV 200ms/DIV

24VIout : 0% Iout : Full load

10V/DIV 200ms/DIV 10V/DIV 200ms/DIV

DC BA

DC BA

DC BA

DC B A

DC BA

DC BA

← V i n →

← 0 V →

←Vout→

← V i n →

← 0 V →

←Vout→

← V i n →

← 0 V →

←Vout→

TDK-Lambda T-11

RWS300B2.5 出力立ち下がり特性Output fall characteristics Conditions Vin : 100 VAC (A)

110 VAC (B)200 VAC (C)265 VAC (D)

Ta : 25 ℃

5VIout : 0% Iout : Full load

2V/DIV 10s/DIV 2V/DIV 20ms/DIV

12VIout : 0% Iout : Full load

5V/DIV 10s/DIV 5V/DIV 20ms/DIV

24VIout : 0% Iout : Full load

10V/DIV 10s/DIV 10V/DIV 20ms/DIV

ABCD

ABCD BCD A

ABCD

BCD A

BCD A

← V i n →

← 0 V →

←Vout→

← V i n →

← 0 V →

←Vout→

← V i n →

← 0 V →

←Vout→

TDK-Lambda T-12

RWS300B2.6 過電流保護特性 2.7 過電圧保護特性Over current protection (OCP) characteristics Over voltage protection (OVP) characteristics

Conditions Vin : 110 VAC Conditions Vin : 100 VACTa : -10 ℃ Iout : 0 %

25 ℃ Ta : 25 ℃50 ℃

5V

2V/DIV 10s/DIV

12V

5V/DIV 10s/DIV

24V

10V/DIV 10s/DIV

0

2

4

6

8

10

12

0 50 100 150

Out

put v

olta

ge (V

)

Output current (%)

0

1

2

3

4

5

6

0 50 100 150

Out

put v

olta

ge (V

)

Output current (%)

0

5

10

15

20

25

0 50 100 150

Out

put v

olta

ge (V

)

Output current (%)

OVP Point

OVP Point

OVP Point

0V →

Vout →

0V →

Vout →

0V →

Vout →

TDK-Lambda T-13

RWS300B2.8 過渡応答(負荷急変)特性Dynamic load response characteristics Conditions Vin : 110 VAC

Iout : 50 % 100 % (tr = tf = 50us)

Ta : 25 ℃

5Vf = 100Hz f = 1kHz

12Vf = 100Hz f = 1kHz

24Vf = 100Hz f = 1kHz

100mV/DIV 2ms/DIV 200μs/DIV+0.72% -0.82% +0.64% -0.73%

100mV/DIV

100mV/DIV 2ms/DIV 100mV/DIV 200μs/DIV+0.52% -0.49% +0.33% -0.36%

100mV/DIV 2ms/DIV 100mV/DIV 200μs/DIV+0.11% -0.18% +0.08% -0.16%

←Iout:0%→

← V o u t →

← I o u t →

←Iout:0%→

← V o u t →

← I o u t →

←Iout:0%→

← V o u t →

← I o u t →

TDK-Lambda T-14

RWS300B2.9 入力電圧瞬停特性

Response to brown out characteristics Conditions Ta : 25 ℃Iout : Full load

瞬停時間 Interruption timeA : 出力電圧が低下なし Output voltage does not drop.B : 出力電圧の低下が0Vまでいかない Output voltage drop down not reaching 0V.C : 出力電圧が0Vまで低下 Output voltage drops until 0V.

Vin : 110VAC Vin : 200VAC

A = 32ms, C = 33ms A = 34ms, C = 35ms

2V/DIV 50ms/DIV 2V/DIV 50ms/DIV

Vin : 110VAC Vin : 200VAC

A = 27ms, C = 28ms A = 28ms, C = 29ms

5V/DIV 50ms/DIV 5V/DIV 50ms/DIV

Vin : 110VAC Vin : 200VAC

A = 27ms, C = 28ms A = 28ms, C = 29ms

10V/DIV 50ms/DIV 10V/DIV 50ms/DIV

5V

12V

24V

A C A C

A C A C

A C A C

← 0 V →

← V i n →

← V o u t →

← 0 V →

← V i n →

← V o u t →

← 0 V →

← V i n →

← V o u t →

TDK-Lambda T-15

RWS300B2.10 入力サージ電流(突入電流)波形Inrush current waveform

12VConditions Vin : 100 VAC

Iout : Full load Ta : 25 ℃

10A/DIV 100ms/DIV 10A/DIV 100ms/DIV

Conditions Vin : 200 VACIout : Full load

Ta : 25 ℃

20A/DIV 100ms/DIV 20A/DIV 100ms/DIV

Switch on phase angle of input AC voltageφ = 0°

Switch on phase angle of input AC voltageφ = 90°

Switch on phase angle of input AC voltageφ = 0°

Switch on phase angle of input AC voltageφ = 90°

← Iin →

← Vin →

← Iin →

← Vin →

TDK-Lambda T-16

RWS300B2.11 高調波成分Input current harmonics Conditions Iout : Full load

Ta : 25 ℃12V

2.12 入力電流波形Input current waveform Conditions Iout : Full load

Ta : 25 ℃12V

Vin : 110VAC Vin : 200VAC

5A/DIV 5ms/DIV 5A/DIV 5ms/DIV

0.001

0.010

0.100

1.000

10.000

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

Har

mon

ic c

urre

nt (A

)

Harmonic order

0.001

0.010

0.100

1.000

10.000

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

Har

mon

ic c

urre

nt (A

)

Harmonic order

Vin : 110 VAC

Vin : 230 VAC

IEC61000-3-2 Limit (class A)

IEC61000-3-2 Limit (class A)

←Vin→

←Iin→

TDK-Lambda T-17

RWS300B2.13 リーク電流特性

Leakage current characteristics Conditions Iout : 0 %Full load

Ta : 25 ℃Equipment used : 3156 (HIOKI)

12V

f : 50 Hz

f : 60 Hz

0.0

0.1

0.2

0.3

0.4

0.5

80 120 160 200 240 280

Leak

age

curr

ent (

mA

)

Input voltage (VAC)

0.0

0.1

0.2

0.3

0.4

0.5

80 120 160 200 240 280

Leak

age

curr

ent (

mA

)

Input voltage (VAC)

TDK-Lambda T-18

RWS300B2.14 出力リップル、ノイズ波形Output ripple and noise waveform Conditions Vin : 110 VAC

Iout : Full load Ta : 25 ℃

20mV/DIV 2μs/DIV

20mV/DIV 2μs/DIV

20mV/DIV 2μs/DIV

5V

12V

24V

TDK-Lambda T-19

RWS300B2.15 EMI特性

Electro-Magnetic Interference characteristics Conditions Vin : 230 VACIout : Full load

Ta : 25 ℃  雑音端子電圧

Conducted Emission

5VPhase : N

Ref. Limit MeasureData (dB) (dB)

QP 62.2 51.3

AV 52.2 39.7

東サービスセンター

Phase : L

Phase : LRef. Limit Measure

Data (dB) (dB)

QP 62.0 54.1

AV 52.0 48.1

EN55011-B,EN55032-B,FCC-Bの限界値はVCCI class Bの限界値と同じLimit of EN55011-B,EN55032-B,FCC-B are same as its VCCI class B.

(243kHz)Point B

Point A(238kHz)

A

B VCCI Class BQP Limit

VCCI Class BAV Limit

VCCI Class BAV Limit

VCCI Class BQP Limit

TDK-Lambda T-20

RWS300B2.15 EMI特性

Electro-Magnetic Interference characteristics Conditions Vin : 230 VACIout : Full load

Ta : 25 ℃  雑音端子電圧

Conducted Emission

12VPhase : N

Ref. Limit MeasureData (dB) (dB)

QP 62.0 52.0

AV 52.0 44.0

Phase : L

Phase : LRef. Limit Measure

Data (dB) (dB)

QP 62.0 52.7

AV 52.0 48.1

EN55011-B,EN55032-B,FCC-Bの限界値はVCCI class Bの限界値と同じLimit of EN55011-B,EN55032-B,FCC-B are same as its VCCI class B.

Point B(242kHz)

Point A(241kHz)

A

B VCCI Class BQP Limit

VCCI Class BAV Limit

VCCI Class BQP Limit

VCCI Class BAV Limit

TDK-Lambda T-21

RWS300B2.15 EMI特性

Electro-Magnetic Interference characteristics Conditions Vin : 230 VACIout : Full load

Ta : 25 ℃  雑音端子電圧

Conducted Emission

24VPhase : N

Ref. Limit MeasureData (dB) (dB)

QP 62.3 51.4

AV 52.3 42.1

Phase : L

Phase : LRef. Limit Measure

Data (dB) (dB)

QP 62.2 52.7

AV 52.2 47.4

EN55011-B,EN55032-B,FCC-Bの限界値はVCCI class Bの限界値と同じLimit of EN55011-B,EN55032-B,FCC-B are same as its VCCI class B.

Point B(236kHz)

Point A(235kHz)

A

B VCCI Class BQP Limit

VCCI Class BAV Limit

VCCI Class BAV Limit

VCCI Class BQP Limit

TDK-Lambda T-22

RWS300B2.15 EMI特性

Electro-Magnetic Interference characteristics Conditions Vin : 230 VACIout : Full load

Ta : 25 ℃  雑音電界強度

Radiated Emission

HORIZONTAL VERTICAL

HORIZONTAL VERTICAL

HORIZONTAL VERTICAL

EN55011-B,EN55032-Bの限界値はVCCI class Bの限界値と同じLimit of EN55011-B,EN55032-B are same as its VCCI class B.

表示はピーク値Indication is peak values.

5V

12V

24V

QPQP

QP QP

QP QP

TDK-Lambda T-23