reinforced fly ash slope using different geosyntheticsigs/ldh/conf/2011/articles/theme - j...

4
Proceedings of Indian Geotechnical Conference December 15-17,2011 , Kochi (Paper No. J 194) REINFORCED FLY ASH SLOPE USING DIFFERENT GEOSYNTHETICS S.Adhana Post Graduate Student, Civil Engineering Department, IIT Bombay-400076, Email:[email protected] J.N. Mandal Professor, Civil Engineering Department, IIT Bombay -400076, Email:[email protected] ABSTRACT: The model tests were conducted in the laboratory without and with reinforcement in fly ash steep slopes on soft foundation to check the stability of steep slope. In this experiment fly ash is used as a filling material and two types of reinforcement were used: (a) Three dimensional circular geocell strip (diameter =5 cm and height=1cm) made from waste plastic bottles and (b) polyester geogrid strip (width = 4.5 cm and thickness = 0.3 mm). The properties of geocell and geogrid strip are determined. From the experiments, load and settlement have measured. From these data, load –settlement curves have reported. It has been observed from test results that load carrying capacity of geocell is more than that of geogrid strip. The deformation of geocell is slightly more than that of geogrid strip. A Finite Element Method (F.E.M.) was also evaluated using PLAXIS 8 version. The failure pattern, deformations and factor of safety are reported based on analytical programme. The results from experimental data and analytical programme are compared and reported. INTRODUCTION The three dimensional circular geocell strip is 10mm deep 50 mm diameter and 210 mm length open honeycomb cellular structure constructed by cutting from the waste plastic bottles and polyester geogrid strip is 40 mm width and 210 mm in length used in the present study. The series of interlocking cells are filled with flyash collected from thermal power plant from Gujarat. The circular geocell confine the flyash within its pocket. Many authors such as Edgar [1], Krishnaswami et al. [2], Mhaiskar and Mandal [3], Rowe and Mylleville [4], Khedkar and Mandal [5,6] and Mandal and Bhardwaj [7] have used metallic and cellular reinforcement for reinforced soil walls and slopes. Here a model test with waste plastic circular geocell strip and geogrid strip was used for the construction of steep slopes using waste flyash. The experimental and finite element analysis was reported.. PROPERTIES OF FLY ASH ,CIRCULAR GEOCELL AND GEOGRID STRIP The properties of the fly ash are: specific gravity = 2.18, D 60 =0.045mm, D 30 =0.014mm, D 10 =0.003mm, coefficient of uniformity (C u ) =15, coefficient of curvature (C c ) =1.45, cohesion=3 kN/m 2 , angle of internal friction=15 0 , optimum moisture content = 25.02% and maximum dry density = 11.91 kN/m 3 . The properties of the circular geocell strip are: mass= 264.2 gm/m 2 , thickness = 0.4 mm, tensile strength = 12 kN/m. The properties of the geogrid strip are: mass= 595.5 gm/m 2 , thickness = 0.3 mm, tensile strength = 9.2 kN/m. MODEL TEST SETUP The model test set up used in this study is fabricated at geosynthetics testing laboratory at IIT Bombay and the dimension of the test set up is as follows: length= 700 mm, width= 400 mm and height= 500 mm. The line sketch of model is shown in the Fig.-1 Test was performed in the laboratory without and with circular geocell reinforcement. One side of the model set was covered with Perspex sheet to observe the failure pattern. Fig.1 Test set up To minimize the friction effect, oil is applied to the inner side of the set up. Surcharge was applied to get the failure. The procedure adopted in this study is in the following manner: Fly ash foundation is prepared of length= 700 mm, width= 400 mm and depth= 150 mm. A slope of height= 300 mm is prepared over the foundation at a slope angle of 60 0 as shown in the Fig. 2. The fly ash is compacted at 23% on dry side of optimum moisture content. The fly ash was compacted 553

Upload: others

Post on 20-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: REINFORCED FLY ASH SLOPE USING DIFFERENT GEOSYNTHETICSigs/ldh/conf/2011/articles/Theme - J 12.pdf · geogrid strip. The factor of safety satisfies the design of steep circular geocell

Proceedings of Indian Geotechnical Conference December 15-17,2011 , Kochi (Paper No. J 194)

REINFORCED FLY ASH SLOPE USING DIFFERENT GEOSYNTHETICS

S.Adhana Post Graduate Student, Civil Engineering Department, IIT Bombay-400076, Email:[email protected]

J.N. Mandal Professor, Civil Engineering Department, IIT Bombay -400076, Email:[email protected]

ABSTRACT: The model tests were conducted in the laboratory without and with reinforcement in fly ash steep slopes on

soft foundation to check the stability of steep slope. In this experiment fly ash is used as a filling material and two types of

reinforcement were used: (a) Three dimensional circular geocell strip (diameter =5 cm and height=1cm) made from waste

plastic bottles and (b) polyester geogrid strip (width = 4.5 cm and thickness = 0.3 mm). The properties of geocell and

geogrid strip are determined. From the experiments, load and settlement have measured. From these data, load –settlement

curves have reported. It has been observed from test results that load carrying capacity of geocell is more than that of

geogrid strip. The deformation of geocell is slightly more than that of geogrid strip.

A Finite Element Method (F.E.M.) was also evaluated using PLAXIS 8 version. The failure pattern, deformations and

factor of safety are reported based on analytical programme. The results from experimental data and analytical programme

are compared and reported.

INTRODUCTION

The three dimensional circular geocell strip is 10mm deep

50 mm diameter and 210 mm length open honeycomb

cellular structure constructed by cutting from the waste

plastic bottles and polyester geogrid strip is 40 mm width

and 210 mm in length used in the present study. The series

of interlocking cells are filled with flyash collected from

thermal power plant from Gujarat. The circular geocell

confine the flyash within its pocket. Many authors such as

Edgar [1], Krishnaswami et al. [2], Mhaiskar and Mandal

[3], Rowe and Mylleville [4], Khedkar and Mandal [5,6]

and Mandal and Bhardwaj [7] have used metallic and

cellular reinforcement for reinforced soil walls and slopes.

Here a model test with waste plastic circular geocell strip

and geogrid strip was used for the construction of steep

slopes using waste flyash. The experimental and finite

element analysis was reported..

PROPERTIES OF FLY ASH ,CIRCULAR GEOCELL

AND GEOGRID STRIP

The properties of the fly ash are: specific gravity = 2.18,

D60=0.045mm, D30=0.014mm, D10=0.003mm, coefficient of

uniformity (Cu) =15, coefficient of curvature (Cc) =1.45,

cohesion=3 kN/m2, angle of internal friction=150, optimum

moisture content = 25.02% and maximum dry density =

11.91 kN/m3.

The properties of the circular geocell strip are: mass=

264.2 gm/m2, thickness = 0.4 mm, tensile strength = 12

kN/m.

The properties of the geogrid strip are: mass= 595.5

gm/m2, thickness = 0.3 mm, tensile strength = 9.2 kN/m.

MODEL TEST SETUP

The model test set up used in this study is fabricated at

geosynthetics testing laboratory at IIT Bombay and the

dimension of the test set up is as follows: length= 700 mm,

width= 400 mm and height= 500 mm.

The line sketch of model is shown in the Fig.-1 Test was

performed in the laboratory without and with circular

geocell reinforcement. One side of the model set was

covered with Perspex sheet to observe the failure pattern.

Fig.1 Test set up

To minimize the friction effect, oil is applied to the inner

side of the set up. Surcharge was applied to get the failure.

The procedure adopted in this study is in the following

manner:

Fly ash foundation is prepared of length= 700 mm,

width= 400 mm and depth= 150 mm.

A slope of height= 300 mm is prepared over the

foundation at a slope angle of 600 as shown in the Fig.

2.

The fly ash is compacted at 23% on dry side of

optimum moisture content. The fly ash was compacted

553

Page 2: REINFORCED FLY ASH SLOPE USING DIFFERENT GEOSYNTHETICSigs/ldh/conf/2011/articles/Theme - J 12.pdf · geogrid strip. The factor of safety satisfies the design of steep circular geocell

S.Adhana & J.N.Mandal

using modified proctor hammer in subsequent layer of

60 mm.

When entire compaction is over, the incremental load

is applied through hydraulic jack on the plate of size

350 mm x 100 mm placed at the distance of 50 mm

from the edge of the slope.

Fig.2 Model of unreinforced fly ash slope

Two LVDT’s are placed on the slope face to measure

the lateral deformation of the slope and two LVDT’s

are placed on the top of plate to measure the vertical

deformation of the slope.

Failure surface has been observed.

CASE 1: UNREINFORCED FLY ASH SLOPE

The failure surface of unreinforced slope as obtained is

shown in the Fig. 3.

Fig. 3 Failure surface of unreinforced fly ash slope

CASE 2: REINFORCED FLY ASH SLOPE USING

CIRCULAR GEOCELL STRIP

Circular geocell strip of size 50 mm width x 210 mm in

length is made by joining unit cell by stapling and use of

adhesive as shown in the Fig. 4. Fly ash slope is reinforced

with Circular geocell strip having length =210 mm and at a

vertical spacing of every 75mm in 4 layers and horizontal

spacing of 20 mm. The model prepared is shown in the

Fig. 5.

The failure surface as obtained is shown in the Fig. 6.

Fig.4 Circular geocell strip

Fig.5 Model of reinforced fly ash slope with circular

geocell strip

Fig.6 Failure surface of reinforced fly ash slope with

circular geocell strip

CASE 3: REINFORCED FLY ASH SLOPE USING

POLYESTER GEOGRID STRIP

Geogrid strip of size 40 mm width x 210 mm in length is

used in the present study. Laying of geogrid strip is shown

in the Fig. 7.

554

Page 3: REINFORCED FLY ASH SLOPE USING DIFFERENT GEOSYNTHETICSigs/ldh/conf/2011/articles/Theme - J 12.pdf · geogrid strip. The factor of safety satisfies the design of steep circular geocell

Reinforced fly ash slope using different Geosynthetics

Fly ash slope is reinforced with geogrid strip having length

=210 mm and at a vertical spacing of every 75mm in 4

layers and horizontal spacing of 20 mm. The model

prepared is shown in the Fig. 8.

Fig.7 Laying of polymer geogrid strip

Fig.8 Model of reinforced fly ash slope with polyester

geogrid\

The failure surface of fly ash slope as obtained is shown in

the Fig. 9.

Fig.9 Failure surface of reinforced fly ash slope with

polyester geogrid

LOAD –DEFORMATION CURVE

Load deformation curve for three different cases are shown

in Fig. 10 comparison is being made between three cases.

Fig.10 Load –Deformation curve for 3 different cases

FINITE ELEMENTAL ANALYSIS

A finite element analysis using PLAXIS version 8 has been

used for unreinforced and reinforced soil cases. The failure

pattern and total displacement of unreinforced soil slope is

9.62 mm as shown in Fig.11. The failure pattern and total

displacement of reinforced circular geocell strip fly ash

slope is 22.56 mm as shown in Fig.12. The failure pattern

and total displacement of reinforced fly ash slope using

geogrid strip is 19.49 mm as shown in Fig.13.

Fig.11 Total displacement of unreinforced soil slope

Fig.12 Total displacement of reinforced soil slope using

circular geocell strip

555

Page 4: REINFORCED FLY ASH SLOPE USING DIFFERENT GEOSYNTHETICSigs/ldh/conf/2011/articles/Theme - J 12.pdf · geogrid strip. The factor of safety satisfies the design of steep circular geocell

S.Adhana & J.N.Mandal

Fig. 13 Total displacement of reinforced soil slope using

polyester geogrid strip

RESULT AND DISCUSSION

Table 1 shows the load deformation of unreinforced and

reinforced soil with circular geocell strip and geogrid strip.

From the experimental results it has been observed that

both Geocell strip and geogrid strip reinforced steep soil

can take more load than that of unreinforced soil. Load

carrying capacity of geocell strip is more as compared to

geogrid strip. The increment of stress is due to the

confinement effect of geocell and or hoop stress. The factor

of safety for unreinforced and reinforced circular geocell

strip and geogrid strip are tabulated in Table 2

Table 1 Load deformation of unreinforced and reinforced

Type Factor of safety

(Slip circle

method)

Factor of

safety (FEM

Analysis)

Unreinforced 0.664 0.456

Reinforced with

circular geocell strip

2.55 1.86

Reinforced with

geogrid strip

1.88 1.69

Table 2 Factor of safety for unreinforced and reinforced fly

ash slope

Type Load

(Kg)

Deformation

(Experimental)

(mm)

Deformation

(FEM analysis)

(mm)

Unreinforced 70 8.6 9.62

Reinforced with

circular geocell strip

500 20.56 22.56

Reinforced with

polyester geogrid

strip

450 18.76 19.49

It has been noted that the unreinforced soil fail. On the

other hand reinforced geocell strip and geogrid strip fly ash

slope is safe.

CONCLUSION

The abundant of fly ash is available in India. The use of

wastage fly ash can be suitable for the construction of

infrastructure like embankments, reinforced soil walls and

slopes. The waste plastic bottle was used in the form of

mattress and strips form. The circular geocell reinforcement

develop significant amount of confinement and/or hoop

stresses. The geocell strip is more efficient than that of

geogrid strip. The factor of safety satisfies the design of

steep circular geocell reinforced soil slope.

REFERENCES

1 .Edgar,S.(1984), The use of high tensile polymer grid

mattress on the mussel burgh and Portobello Bypass,

procee .Engg polymer grid reinforcement in civil engineering,ICE,London,pp.3-5.

2. Krishnaswamy,N.R.,Rajagopal,K.and Latha,G.M(2000),

Model studies on geocell supported

embankmentconstructed over soft clay foundation,

Geotechnical testing journal, No.23, Vol.1,pp.45-54.

3. Mhaiskar,S.K. and Mandal,J.N.(1996),Investigation on

soft clay sub grade strengthening using

geocells,construction and building materials,10(4),281-286.

4. Rowe,R.K.and Mylleville Brian,L.J.(1993),The stability

of embankment reinforced wih steel, Journal of Canadian geotechnic,30,768-780

5. Khedkar,M.S. and Mandal,J.N.(2010),Behavior of

cellular reinforced soil wall under uniformly

distributed load, 9th International conference on

geosynthetics, guaruja, Brazil, 2010,pp.1693-1698.

6. Khedkar,M.S. and Mandal,J.N.(2009), Pullout

behaviour of cellular reinforcements, International

Journal of Geotextile and Geomembranes,27(4), 262-

271.

7. Mandal,J.N., and Bhardwaj,D.K. (2008), Study on

polypropylene fibre reinforced fly ash slopes,12th

international conference of international association for computer methods and advances in geomechnics,

Goa, India, 3,3778-3786.

8. Broere, W., Brinkgreve R.,(2010) Plaxis manual,

Plaxis version 8.

556