    A FAct-BAsed Guide on Moisture VApor protection

    reducinG Moisture VApor eMissions in concrete construction

  • 2

    Moisture VApor eMissionsprotect Your FloorinG inVestMent FroM

    Moisture vapor is a hot topic in any type of construction where you have concrete on, above, or below grade. Moisture vapor emissions through a concrete slab in any building can contribute to costly floor good failures, down time, and slow construction schedules.

    over the past 20 years, the frequency of moisture vapor emission issues has increased. several contributing factors include: •Thelossofasbestosasaningredientinresilientflooring •Thelossofsolventsfromadhesiveandcoatingsystems •Increaseduseofwaterforeasierplacementofstructural

    and lightweight concrete •Fasttrackconstructionschedules

    HighpH(alkalinity)canbeextremelydetrimentaltolatex-basedadhesivesas well. Moisture vapor moving through the concrete to the surface will accumulate at the bond line between adhered flooring material and the concrete. the combination of moisture and salts present in the concrete combine to create a high pH environment. the high pH condensate begins tobreakdownthewater-basedadhesive,resultinginafloorgoodfailure.

  • 3

    Moisture MitiGAtion sYsteMensurinG An eFFectiVe

    in order to address the prevalence of floor good failures relating to inadequate moisture vapor barriers, AstM committee F06 on resilient Floor coverings developed and approved AstM F3010-13 – “standard practice for two-component resin Based Membrane-Forming Moisture Mitigation systems for use under resilient Floor coverings”.

    this new standard applies specifically to two-component, resin-based moisture mitigation systems. it discusses the application of these moisture vapor barriers over concrete floors with high moisture content. AstM F3010-13 also discusses the properties and performance requirements of these products prior to installation of resilient floor coverings.

    in order to meet AstM F3010-13 these products need to meet the following criteria: 1. reduce moisture transmission to no more than 0.1 perm. 2. Must define perm as grains/hr/ft2/in•Hg. 3.Manufacturermustspecifymilthicknessrequiredtomeetthe

    0.1 perm rating. 4. products must be tested in accordance with AstM e96.

    AstM F3010-13 does not cover the following membrane-forming and non-membrane-forming moisture mitigation systems: •Systemsthatchemicallyreactwithanycomponentoftheconcrete

    forming a gel or crystalline substance within the concrete •Penetrating,water-orsolvent-basedcompoundsformingadiscontinuous

    membrane on the concrete surface •Water-basedmembrane-formingsystems

    Gym floor failure due to moisture vapor emissions.treatment with surface applied moisture vapor barrier will help protect the new gym floor.

  • 4

    BELOW-SLABBARRIERS

    BreAcHABle

    delAYed VApor releAse

    does not Address pH leVels

    precipitAtion resets drYinG tiMe

    Rocks,shoes,wire,rebar,heavyequipment,etc.cancausetearsandholes, compromising the barrier.

    Whilethebelow-slabsystempreventsgroundmoisturefromcomingthrough the slab, this system does nothing to reduce moisture vapor emissions from new concrete which often releases moisture months after installation.

    Because the barrier is under the slab, it does nothing to address pH levels in the concrete itself.

    Concreteslabstakeapproximately30daysper1"ofconcreteunderideal conditions to reach acceptable moisture levels for installation of floor goods.Iftheslabisfurtherexposedtoprecipitation,theclockresets.

    concrete slab on or Below Grade

    under slab Vapor Barrier

  • 5

    surFAce-Applied Moisture VApor BArriers

    coMplete coVerAGe

    reduces Moisture VApor FroM All MAteriAls

    proVides A pH BArrier

    VeriFied independent testinG

    cannot be torn, resulting in complete, durable coverage.

    Because the barrier is applied to the top of the concrete, it stops moisture vapor emissions from concrete, ground and environmental conditions.

    NotaffectedbypHanddoesnotallowalkalinestoconcentrateatthe new bond layer.

    Meets AstM F3010, which requires a perm rating of no greater than 0.1 grains/hr/ft2/in•Hg.Verifymanufacturer’srequiredmilthicknesstoachieve perm rating.

    concrete

    surface Applied Moisture Vapor Barrier

  • 6

    penetrAnt/silicAte

    BreAtHABle

    AdHesiVe MAnuFActurers require reMoVAl

    ONLyLOWERSpHASSOCIATEdWITHCALCIuMHydROxIdE

    liMited independent testinG

    not speciFicAllY desiGned For tHis ApplicAtion

    Allows moisture to penetrate slab.

    Adhesives will not bond to penetrants/silicates.

    pHlevelsassociatedwithsodiumhydroxideandpotassiumhydroxideremain.

    Originallydesignedforexposedconcrete,moisturevaporemissionsis secondary use.

    does not meet AstM F3010 perm rating. AstM F3010 now requires a perm rating of no greater than 0.1 grains/hr/ft2/in•Hg(0.1perm).

    concrete

    penetrant/silicate

  • 7

    surFAce-Applied Moisture VApor BArriers

    HiGHest Moisture VApor reduction cApABilities

    eAsilY Applied

    Best resistAnce to AlkAlinitY up to pH 14

    VeriFied independent testinG

    can reduce MVer rates of up to 25 lbs to 3 lbs or less, tested using a calcium chloride test.

    installation is permanent and application on most jobs is finished within a few hours.

    offers protection from the high pH levels associated with moisture vapor emissions associated with adhesive failures.

    Meets AstM F3010, which requires a perm rating of no greater than 0.1 grains/hr/ft2/in•Hg.Verifymanufacturer’srequiredmilthicknesstoachieve perm rating.

    concrete

    surface Applied Moisture Vapor Barrier

    ForMulAtions desiGned For Moisture MitiGAtion

    product was developed for the application, resulting in greater success.

  • 8

    dispersiVe MeMBrAnes

    not conduciVe to HeAVY trAFFic

    POTENTIALFORBACTERIALgROWTH

    VerY little independent testinG

    Adds tHickness to tHe Floor

    Theflexiblenatureofthematslimitsfloorgoodchoices.

    since the mats are pliable, they cannot withstand heavy traffic/point loads.

    Moisture can condense on organic material left on the concrete presenting the potential for bacterial growth.

    chemical reactions between moisture and elements in concrete create high pH environments.

    Thissystemaddsthicknesstothefloorbeforeanyfloorgoodsareinstalled.

    concrete

    dispersive Membrane

    MediuM pH resistAnce

    does not meet AstM F3010 perm rating. AstM F3010 now requires a perm rating of no greater than 0.1 grains/hr/ft2/in•Hg(0.1perm).

    MATSCANONLyBEuSEdWITHCERTAINFLOORINgSySTEMS

  • 9

    surFAce-Applied Moisture VApor BArriers

    FORuSEWITHANyFLOORgOOdS

    CANWITHSTANdHEAVyTRAFFIC

    NOPOTENTIALFORBACTERIALgROWTH

    Best resistAnce to AlkAlinitY up to pH 14

    VeriFied independent testinG

    no Added Floor HeiGHt

    design possibilities are not limited by flooring compatibility when paired with an underlayment system.

    A solid surface that can withstand most traffic.

    Materials provide no source for bacterial growth.

    offers protection from the high pH levels associated with adhesive failures due to moisture vapor emissions.

    Meets AstM F3010, which requires a perm rating of no greater than 0.1 grains/hr/ft2/in•Hg.Verifymanufacturer’srequiredmilthicknesstoachieve perm rating.

    Surfaceappliedmoisturevaporbarriersdonotaddthicknesstotheoverallfloor height.

    concrete

    surface Applied Moisture Vapor Barrier

    concrete

  • 10

    deHuMidiFicAtionMoisture

    released through dehumidification commercial

    dehumidifier

    concrete

    onlY Addresses Moisture in tHe top oF tHe slAB

    MAY or MAY not Be successFul

    no predeterMined scHedule

    NOExTENdEdWARRANTy

    CANNOTBEuSEdONNEWCONCRETE

    Moisturecanexistthroughoutslab,notonlythetop.

    Thereisnotestdata/guaranteeitwillworkasapermanentsolution.

    Noideahowlongmoisturereductionprocesscantake.

    since it only addresses the symptom, not the source, moisture may reappear.

    Acceleratesdryingwhichcancausecracking,curlingandphysical property loss.

  • 11

    surFAce-Applied Moisture VApor BArriers

    concrete

    surface Applied Moisture Vapor Barrier

    concrete

    commercial dehumidifier

    MitiGAtes Moisture VApor eMissions

    proVen solution

    scHeduled proGrAM

    WARRANTIEdSySTEM

    NEWOROLdCONSTRuCTION

    since it creates a barrier, moisture vapor emissions are reduced significantly.

    proven on projects with a variety of applications throughout north America andbackedbyindependentlabtesting.

    Constructionschedulesstayontrackwithaninstallationschedule.

    Backedbymanufacturer’swarranty.

    can be used in new construction, including 5 days after concrete installation.

  • 12

    Moisture MitiGAtion SOLuTIONSFROMMAxxON

    Maxxon®CorporationnowoffersMaxxon®dPM(dampProofMembrane)andMaxxon®MVP(MoistureVaporProtection),surfaceappliedmoisturevapor barriers that prevent the passage of moisture vapor through slabs on, below or above grade.

    MaxxondPMandMaxxonMVPreducemoisturevaporemissionsofupto25lbs.to3lbs.orlessandprovideahighalkalinitybarrier(uptopH14),preventing the delamination of adhesives, floor coverings and coatings. MaxxondPMalsopreventscapillaryinfiltrationofoilorotherchemicalsfrom the ground and can be used to treat oil contaminated slabs.

    MaxxondPMandMaxxonMVPinstallquicklyandarereadytoreceiveanapprovedMaxxonunderlaymentthedayafterinstallation.Idealforoldbuildings without a vapor barrier or new buildings, covering even five-day-old concrete:

    WhenMaxxondPM/MaxxonMVPistoppedwithaMaxxonunderlayment,* the system offers a single source warranty — our assurance toyouthatintheunlikelyeventissuesshouldarise,wewillstandbehindthe entire system.

    *Mustbeinstalledtorequiredmilthicknessaccordingtomanufacturer’srecommendedyieldnecessarytomeetASTMF3010permrating.

    •Industrial/retailfacilities•Hospitalsandschools•gymfloors

    •Officebuildings•Residentialslabs•Foodprocessingplants

    For more info: 800-356-7887 •Email:[email protected]

    www.MaxxonCorporation.com

    Another superior product from: Maxxon® Corporation • 920 Hamel Road • P.O. Box 253 Hamel, MN 55340 USA • 763-478-9600 • Fax: 763-478-2431

    MADE IN THE USA

    ©2014 Maxxon Corporation. All Rights Reserved. Maxxon DPM, Maxxon MVP and associated logos are registered trademarks of Maxxon® Corporation, Hamel, MN, USA. Printed in the USA. #81057, TA500-7747, 10/14.