rayflex sistemas y fluidos s.a. · bridgestone: r1s, r2s pirtek: r1at, r2at certificate retention...

32

Upload: others

Post on 05-Aug-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 2: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 3: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 4: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 5: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 6: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 7: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 8: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 9: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

DNV CERTIFICATIONS

FOR

INTERTRACO HOSES

Page 10: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

DNV

MED - D

CERTIFICATE

Page 11: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 12: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 13: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

DNV

TYPE APPROVAL

CERTIFICATES

Page 14: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 15: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 16: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 17: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 18: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 19: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every
Page 20: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

DNV CERTIFICATIONS

FOR

INTERTRACO / BRIDGESTONE

HOSES

Page 21: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

DNV

TYPE APPROVAL

CERTIFICATES

Page 22: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

<0>

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com

Form No.: TA 1411a Issue: October 2009 Page 1 of 4

DET NORSKE VERITAS

TYPE APPROVAL CERTIFICATE

CERTIFICATE NO. P-14031

This is to certify that the

Flexible Hoses of Non-Metallic Material with Permanently Fitted Couplings

with type designation(s) R1S - R1AT, R2S - R2AT

Manufactured by

INTERTRACO ITALIA SPA

Suzzara MN, Italy

is found to comply with Det Norske Veritas' Rules for Classification of Ships

Det Norske Veritas' Offshore Standards Det Norske Veritas' Standards for Certification 2.9 No. 5-791.70

Application May be used for hydraulic, fuel oil, lube oil, cargo oil, compressed air, fresh water, sea water

Type: Temperature range: Max. working press.: Sizes: R1S - R1AT -40°C to + 100°C 40 - 225 bar size and type dependent. See certificate R2S - R2AT -40°C to + 100°C 80 - 400 bar see certificate

Høvik, 2012-03-19

for Det Norske Veritas AS This Certificate is valid until

2016-06-30

Marianne Spæren Head of Section

DNV local office: Milan

Tom Berg-Nielsen Surveyor

This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas.

Page 23: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

Certificate No.: P-14031 File No.: 791.70 Job Id.: 262.1-012525-1

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com

Form No.: TA 1411a Issue: October 2009 Page 2 of 4

Product description Type EN 853 1SN/SAE J517 100R1S Synthetic rubber hose with one internal steel wire braid. Cover of synthetic rubber Coupling types: K, J and B+SN03T Type EN 853 2SN/SAE J517 100R2S: Synthetic rubber hose with two internal steel wire braids. Cover of synthetic rubber Coupling types: K, J, B+SN03T and B+S0420 Coupling material: Carbon steel and stainless steel. Hose manufacturer: Bridgestone, Tokyo, Japan. Coupling manufacturer: Intertraco Italy SpA, Suzzara MN, Italy

Application/Limitation The hoses can be used in the systems mentioned on the front page for the following working pressures: R1S – R1AT

Sizes Max working pressure

DN inch Size bar

6 ¼” 04 225

10 3/8” 06 180 12 ½” 08 160

16 5/8” 10 130 19 ¾” 12 105

25 1” 16 88

31 1 ¼” 20 63 38 1 ½” 24 50

51 2” 32 40 R2S – R2AT

Sizes Max working pressure DN inch Size bar

6 ¼” 04 400

10 3/8” 06 330

12 ½” 08 275

16 5/8” 10 250 19 ¾” 12 215

25 1” 16 165 31 1 ¼” 20 125

38 1 ½” 24 90

51 2” 32 80

Temperature range: -40°C to +100°C

All hose assemblies delivered under this type approval certificate shall be in compliance with an assembly procedure issued by the certificate holder. Each hose assembly is before delivery to be hydraulic pressure tested to 1.5 times the maximum working pressure. Hose assemblies delivered from the certificate holder shall be delivered with the following documentation: - Pressure test report with reference to the type approval certificate. The hose assemblies covered by this type approval may be assembled and delivered by other than the certificate holder under the following conditions: - The assembler is authorised by a written authorization from the certificate holder. The certificate holder shall keep record of all assembler authorisations.

Page 24: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

Certificate No.: P-14031 File No.: 791.70 Job Id.: 262.1-012525-1

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com

Form No.: TA 1411a Issue: October 2009 Page 3 of 4

- Hose assemblies are in accordance with an assembly procedure issued by the certificate holder and the assembler has proved their qualifications by burst testing of a selection of hose/coupling combinations. One sample of each hose type is to be burst tested and the testing is to be witnessed by DNV. This testing is to be performed at least once every 4 years. Hoses used for continuous operation at temperatures higher than 100°C will have their lifetime reduced. In such cases more frequent inspections and planned exchange should be a part of the maintenance program. For compressed air or gases above 16 bar the cover is to be be pin prickled. The hoses shall not replace/be used where permanent piping is possible/required. The hoses must only be fitted in places where they are always accessible. Flexible hoses of these types are not to be used in boiler fronts. The hoses are to be mounted in accordance with the manufacturer’s instructions. It must be possible to shut off from the system all flexible hoses used in systems for compressed air, lube oil, fuel oil and petroleum base hydraulic oil. Each hose is to be hydraulic pressure tested to 1.5 times the maximum working pressure and to be delivered with manufacturer’s pressure test certificate. Hose assemblies with couplings made of carbon steel are not to be used at temperatures below -10°C unless the material is normalized.

Type Approval documentation Tests carried out Impulse test, burst test, fire test, oil resistance of inner tube test, ozone resistance of outer cover test, cold flex test, cover adhersion test, change in length test, dimensional check test

Marking of product For traceability to this type approval the hoses are to be marked with: BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT

Certificate Retention Survey

For retention of the Type Approval, DNV Surveyor shall perform a survey every second year, to verify that the conditions for the type approval are complied with and to witness the following tests on a selection of sizes: - Dimensional check. - Change in length - Leakage test - Burst test The tests shall be performed in accordance with procedures given in Det Norske Veritas' Certification Notes

Page 25: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

Certificate No.: P-14031 File No.: 791.70 Job Id.: 262.1-012525-1

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com

Form No.: TA 1411a Issue: October 2009 Page 4 of 4

no. 2.9 -5-791.70 “Type Approval of Flexible Hoses of Non-Metallic Material” or another recognised standard. The tests are to be performed with the type of couplings fitted that are Type Approved with the hoses. END OF CERTIFICATE

Page 26: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

<0>

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com

Form No.: TA 1411a Issue: October 2009 Page 1 of 5

DET NORSKE VERITAS

TYPE APPROVAL CERTIFICATE

CERTIFICATE NO. P-14032

This is to certify that the

Flexible Hoses of Non-Metallic Material with Permanently Fitted Couplings

with type designation(s) 4SP, 4SH - C25, 4ST, R13 - C35, R15 - 4ST+ - C42, R2C - C25 - C35 - C42, C21, PC25, 4ST+ - PC35 - PC42

Manufactured by

INTERTRACO ITALIA SPA

Suzzara MN, Italy

is found to comply with Det Norske Veritas' Rules for Classification of Ships

Det Norske Veritas' Offshore Standards Det Norske Veritas' Standards for Certification 2.9 No. 5-791.70

Application May be used for hydraulic, fuel oil, lube oil, cargo oil, compressed air, fresh water, sea water

Type: Temperature range: Max. working press.: Sizes: 4SP -40°C to +100°C 280 - 445 bar 3/8", 1/2", 5/8", 3/4" and 1" 4SH - C25 -40°C to +100°C 250 - 420 bar 3/4", 1", 1 1/4", 1 1/2" and

2" 4ST -40°C to +100°C 420 - 350 bar see certificate R13 - C35 -40°C to +121°C 350 bar all sizes see certificate R15 - 4ST+ - C42 -40°c to + 121°C 420 all sizes see certificate R2C - C25 - C35 - C42

-40°C to 100°C/121°C size dependent 250 - 420 bar size dependent

see certificate

C21 -40°C to +120°C 210 bar 2" PC25 -40°C to + 100°C/+120°C size

dependent 250 bar all sizes 5/8", 3/4", 1 1/4", 1 1/2"

4ST+ - PC35 - PC42 -40°C to + 100°C/+120°C size dependent

350 - 420 bar see certificate

Høvik, 2012-03-19

for Det Norske Veritas AS This Certificate is valid until

2016-06-30

Marianne Spæren Head of Section

DNV local office: Milan

Tom Berg-Nielsen Surveyor

This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas.

Page 27: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

Certificate No.: P-14032 File No.: 791.70 Job Id.: 262.1-012525-1

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com

Form No.: TA 1411a Issue: October 2009 Page 2 of 5

Product description EN 856 4SP type : Synthetic rubber inner tube reinforced by 4 steel wire spirals, synthetic rubber cover. Intertraco coupling types: X and B+S0420 EN 856 4SH – C25 type: Synthetic rubber tube reinforced by 4 steel wire spirals, synthetic rubber cover. Intertraco coupling types: J, X, B+S0420, I+S004I 4ST type: Synthetic rubber inner tube reinforced by 4 steel wire spirals, synthetic rubber cover. Intertraco coupling types: K, J, B+S312T, B+S0420 EN 856 R13 – C35 type: SAE J517 100 R13 type. Synthetic rubber inner tube reinforced by 4 or 6 (size dependent) steel wire spirals, synthetic rubber cover. Intertraco coupling types: H, K, J, X, HLZ, I+S004I and I+S006I R15 – 4ST+ - C42 type: SAE J517 100 R15 type. Synthetic rubber inner tube reinforced by 4 or 6 (size dependent) steel wire spirals, synthetic rubber cover Intertraco coupling types: K, J, H, X, XLZ, I+S004I, I+S006I, Z+SZ06I R2C – C25 – C35 – C42 type: Synthetic rubber inner tube reinforced by 2 wire braids or 4 steel wire spirals (size dependent), Synthetic rubber cover. Intertraco coupling types: K, J, X, B+SN03T C21 type: Synthetic rubber inner tube reinforced by 4 steel spirals, synthetic rubber cover. Intertraco coupling types: J, X PC25 type: Synthetic rubber inner tube reinforced by 2 wire braids or 4 steel wire spirals (size dependent) Synthetic rubber cover. Intertraco coujpling types: K, J, X 4ST+ - PC35 – PC42 type: Synthetic rubber inner tube reinforced by 2 wire braids or 4/6 steel wire spirals (size dependent), Synthetic rubber cover Intertraco coupling types: K, J, H, X, I+S004I and I+S006I Hose manufacturer: Bridgestone, Tokyo, Japan Coupling manufacturer: Intertraco Italia SpA, Suzzara MN, Italy Couplings materials: carbon steel and stainless steel.

Application/Limitation The hoses can be used in the systems mentioned on the front page for the following working pressures: 4SP

Sizes Max working pressure DN inch Size bar

10 3/8” 06 445

12 1/2” 08 415 16 5/8” 10 350

19 3/4” 12 350 25 1” 16 280

4SH – C25

Sizes Max working pressure

DN inch Size bar 19 3/4” 12 420

25 1” 16 380

31 1 1/4” 20 325 38 1 1/2” 24 290

51 2” 32 250

Page 28: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

Certificate No.: P-14032 File No.: 791.70 Job Id.: 262.1-012525-1

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com

Form No.: TA 1411a Issue: October 2009 Page 3 of 5

4ST

Sizes Max working pressure

DN inch Size bar

12 1/2” 08 420

16 5/8” 10 350 19 3/4” 12 350

25 1” 16 350 R13 – C35

Sizes Max working pressure DN inch Size bar

16 5/8” 10 350 19 ¾” 12 350

25 1” 16 350

31 1 1/4” 20 350

38 1 1/2” 24 350

51 2” 32 350

R15 – 4ST+ - C42

Sizes Max working pressure

DN inch Size bar

10 3/8” 06 420 12 1/2” 08 420

19 ¾” 12 420 25 1” 16 420

31 1 1/4” 20 420

38 1 1/2” 24 420

51 2” 32 420

R2C – C25 – C35 – C42

Sizes Max working pressure

DN inch Size bar 06 ¼” 04 420

08 5/16” 05 380 10 3/8” 06 350

12 1/2” 08 350

16 5/8” 10 280 19 ¾” 12 250

25 1” 16 250 31 1 1/4” 20 250

C21

Sizes Max working pressure

DN inch Size bar 51 2” 32 210

PC25

Sizes Max working pressure

DN inch Size bar

16 5/8” 10 250 19 3/4” 12 250

31 1 1/4” 20 250 38 1 ½” 24 250

Page 29: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

Certificate No.: P-14032 File No.: 791.70 Job Id.: 262.1-012525-1

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com

Form No.: TA 1411a Issue: October 2009 Page 4 of 5

4ST+ - PC35 – PC42

Sizes Max working pressure DN inch Size bar

06 ¼” 04 420

10 3/8” 06 350

12 1/2” 08 350

16 5/8” 10 420 19 ¾” 12 350

25 1” 16 420 31 1 1/4” 20 350

38 1 ½” 24 350

All hose assemblies delivered under this type approval certificate shall be in compliance with an assembly procedure issued by the certificate holder. Each hose assembly is before delivery to be hydraulic pressure tested to 1.5 times the maximum working pressure. Hose assemblies delivered from the certificate holder shall be delivered with the following documentation: - Pressure test report with reference to the type approval certificate. The hose assemblies covered by this type approval may be assembled and delivered by other than the certificate holder under the following conditions: - The assembler is authorised by a written authorization from the certificate holder. The certificate holder shall keep record of all assembler authorisations. - Hose assemblies are in accordance with an assembly procedure issued by the certificate holder and the assembler has proved their qualifications by burst testing of a selection of hose/coupling combinations. One sample of each hose type is to be burst tested and the testing is to be witnessed by DNV. This testing is to be performed at least once every 4 years. Hoses used for continuous operation at temperatures higher than 100°C will have their lifetime reduced. In such cases more frequent inspections and planned exchange should be a part of the maintenance program. For compressed air or gases above 16 bar the cover is to be pin prickled. The hoses shall not replace/be used where permanent piping is possible/required. The hoses must only be fitted in places where they are always accessible. Flexible hoses of these types are not to be used in boiler fronts. The hoses are to be mounted in accordance with the manufacturer’s instructions. It must be possible to shut off from the system all flexible hoses used in systems for compressed air, lube oil, fuel oil and petroleum base hydraulic oil. Each hose is to be hydraulic pressure tested to 1.5 times the maximum working pressure and to be delivered with manufacturer’s pressure test certificate. Hose assemblies with couplings made of carbon steel are not to be used at temperatures below -10°C unless the material is normalized.

Page 30: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every

Certificate No.: P-14032 File No.: 791.70 Job Id.: 262.1-012525-1

DET NORSKE VERITAS AS, Veritasveien 1, NO-1322 Høvik, Norway, Tel.: +47 67 57 99 00, Fax: +47 67 57 99 11, Org.No. NO 945 748 931 MVA www.dnv.com

Form No.: TA 1411a Issue: October 2009 Page 5 of 5

Type Approval documentation Tests carried out Impulse test, burst test, fire test, oil resistance of inner tube test, ozone resistance of outer cover test, cold flex test, cover adhersion test, change in length test, dimensional check test

Marking of product For traceability to this type approval the hoses are to be marked with:

- BRIDGSTONE: 4SP, 4SH, 4ST, 4ST+, R13, R15, R2C - PIRTEK: C21, C25, C35, C42, PC25, PC35, PC42

Certificate Retention Survey

For retention of the Type Approval, DNV Surveyor shall perform a survey every second year, to verify that the conditions for the type approval are complied with and to witness the following tests on a selection of sizes: - Dimensional check. - Change in length - Leakage test - Burst test The tests shall be performed in accordance with procedures given in Det Norske Veritas' Certification Notes no. 2.9 -5-791.70 “Type Approval of Flexible Hoses of Non-Metallic Material” or another recognised standard. The tests are to be performed with the type of couplings fitted that are Type Approved with the hoses. END OF CERTIFICATE

Page 31: Rayflex Sistemas y Fluidos S.A. · BRIDGESTONE: R1S, R2S PIRTEK: R1AT, R2AT Certificate Retention Survey For retention of the Type Approval, DNV Surveyor shall perform a survey every