r a d i o l o g yFuture is Effortless
Product Spec Sheet
Key Features
AQUATM Radiology is a machine Quality Assurance management solution that standardizes, streamlines and automates QA procedures throughout rediology department and across multiple sites. AQUATM Radiology is a customizable, scriptable web-based application hosted on a server within the department, using the existing network.
AQUATM Radiology manages and standardizes QA procedures for all types of diagnostic imaging equipment, regardless of vendor.
AQUATM Radiology centralizes QA test results, test records, machine details and machine status history.
Audit reports, highlighting missed tests or summarizing routine test results, are easily created.
QA data plots can be generated over time to allow trend analyses.
AQUATM Radiology interfaces with select 3rd party QA devices to import test results and data directly.
SMOOTH ROUTINE USE
Current status of all equipment across the department can be monitored at a glance from the ‘Dashboard’, with easy access to test results of interest.
A user-specific ‘To Do List’ of standardized QA procedures guides workflow and displays test compliance.
AQUATM Radiology tracks the ‘Status’ of each machine (e.g. Working-Clinical, QA, Out of Service, etc.) and reports machine uptime based on machine status history.
Users can search the ‘Library’ and run QA tests off schedule (e.g. after a service event).
AQUATM Radiology provides an electronic machine log book to log machine ‘Events’ and aid root cause analysis, with email notifications.
AQUATM Radiology provides an inventory of equipment and QA devices.
Custom machine reference data can be stored and defined for use as test inputs or baselines.
AQUATM RADIOLOGY TESTS
Binary Pass/Fail tests (e.g. daily safety checklist).
AQUA DxTM incorporates a wide range of tests with different levels of complexity and automation, including:
AQUA DxTM allows users to track equipment calibration factors and expiry dates, including pairs of equipment. Email notification informs users of pending calibration expiry.
Color-coded mandatory safety test indicators help ensure safety-critical systems are tested.
1
All tests are XML script based. The test editor allows existing tests to be customized or new tests to be created, specific to the needs of the department.
Tests and schedules recommended in the following protocols (table 1) are included with AQUATM Radiology as standard:
User-defined machine groups are shown on the Dashboard.
A flexible machine model describes imaging equipment in AQUATM Radiology, allowing users to define the mechanical and dosimetric characteristics of their equipment.
AQUATM Radiology user permissions are based on ‘user’ or ‘user role’.
There is no limit to the number of users, user roles, tests or machines that can be defined in AQUATM Radiology. Active Directory user account logins are supported.
Form-based tests with manual entry of results.
Tests that interface with common QA devices to control the device or import test results.
Automated image-based tests for image quality analysis. AQUATM Radiology incorporates a safety mechanism to ensure that automated tests are performed on the correct machine and from the correct location.
r a d i o l o g yFuture is Effortless
Product Spec Sheet
OPEN AND CONFIGURABLE
TABLE 1: AQUATM RADIOLOGY PRE-CONFIGURED QA PROTOCOLS
All QA tests are driven by customizable XML test scripts, which can be uploaded or edited through the UI.
Existing in house QA routines can be executed as Java libraries by AQUATM Radiology XML test script, with outputs directly to AQUATM Radiology.
AQUATM Radiology allows users to:
set tolerance and baseline values for each test instance.
schedule test instances to individual users or user roles.
custom anchor dates for QC tests performed every ‘n-weeks’.
ORGANIZATION PROTOCOL DESCRIPTION DATE
ACR
JCAHO
IAEA
AAPM
Quality Control Manual Quality Control of computed tomography 2012
2015
2012
2003
CT performance tests
Quality assurance for computed tomography simulators
Diagnostic computed tomography (CT) services
Diagnostic Imaging Requirment
TG-66
Human Health SeriesNo.19
2
All data from the QA program are stored in AQUATM Radiology, allowing several reports to be generated with user-defined ranges and parameters, as described below:
r a d i o l o g yFuture is Effortless
Product Spec Sheet
AQUATM RADIOLOGY REPORTS
TABLE 2: AQUATM RADIOLOGY REPORTS DESCRIPTION
DESCRIPTION OF CONTENTSREPORTS TYPE
EQUIPMENTREPORTS
Machine Uptime Summary of time spent in each available machine status for selected machines, computed against nominal working day and clinical working week as defined in AQUATM Radiology.
Description of machine components and machine reference data mapped to the selected machine.
Information about all machines of the selected type (machine name, model, vendor, serial number, commissioning and decommissioning date, active status).
Machine Details
Equipment Summary
QA POLICY REPORTS
Compliance Summary of QA tests performed on a machine within a selected date range, compared to expected tests.
Audit of test instances created for a machine and summary of deficiencies against ACR recommendations.
Policy Compliance
QA TEST REPORTS
Test Procedure Procedure and specification for each selected test.
Summary of selected test instances, including test instance name, test run pass/fail status, test run date, user who executed the test run, whether test instance is currently scheduled, and whether test was in draft mode at time of test run.
Test Runs report data plus values of all parameters used in the test run.
Test Runs
Test Inputs
Test Parameters Current values of all test parameters in each test instance for the selected test on the selected machine.
Values of all parameters for each test run of selected test instances in the selected time period.
Test Run Details
Values of all parameters for each test run scheduled at the selected testing frequency in the selected date range.
Test Run by Period
3
FIGURE 1: Easy to use plots display user selected data trended over time. Images generated during test runs offer visual verification of results
AQUATM Radiology helps to identify trends in data and potential equipment issues using customizable data plots with the following features:
r a d i o l o g yFuture is Effortless
Product Spec Sheet
AQUATM RADIOLOGY DATA PLOTS
Display of baseline, tolerance, and limit ranges.
Machine events overlaid on top of plots to help interpret data.
Ability to zoom in on areas of interest, select data points to review, and click to access test input forms.
Trending over time for data or vectors, such as beam profiles and depth-dose curves.
Plots can be generated for any test parameter saved in AQUA DxTM. Plot views are driven by the XML test script, allowing users to review and trend the most relevant results.
Each plot can be viewed as ‘absolute data’, ‘absolute difference from baseline’ and ‘relative to baseline’.
Plots can be exported as data (.CSV files) or images.
Spatial Resolution Spatial Resolution - Circular Profile
4
AQUATM Radiology is an open, vendor-neutral system. Its tests can be performed for all imaging devices. It performs fully automated image performance tests for computed tomography scanners using Catphan phantom. Table 2 shows compatibility with Catphan phantom models and relevant automated tests.
r a d i o l o g yFuture is Effortless
Product Spec Sheet
AQUATM RADIOLOGY COMPATIBILITY
TABLE 2: AQUATM RADIOLOGY V2.0 COMPATIBILITY WITH CATPHAN PHANTOMS
AUTOMATED ELECTROMECHANICAL TESTSPHANTOM MODEL AUTOMATED IMAGE PERFORMANCE TEST
CATPHAN 600 CT Number accuracyCT Number uniformitySpatial resolution (MTF measurement)Low-contrast resolutionImage (slice) thicknessImage noiseGeometric accuracy
Alignment of gantry, wall, ceiling lasersScan increment (table indexing)Slice sensitivity profileImage (slice) thicknessGeometric accuracy
CATPHAN 500 CT Number accuracyCT Number uniformitySpatial resolution (MTF measurement)Low-contrast resolutionImage (slice) thicknessImage noiseGeometric accuracy
Alignment of gantry, wall, ceiling lasersScan increment (table indexing)Image (slice) thicknessGeometric accuracy
CATPHAN 503 CT Number accuracyCT Number uniformitySpatial resolution (MTF measurement)Image (slice) thicknessImage noiseGeometric accuracy
Alignment of gantry, wall, ceiling lasersScan increment (table indexing)Image (slice) thicknessGeometric accuracy
CATPHAN 600 CT Number accuracyCT Number uniformitySpatial resolution (MTF measurement)Low-contrast resolutionImage (slice) thicknessImage noiseGeometric accuracy
Alignment of gantry, wall, ceiling lasersScan increment (table indexing)Image (slice) thicknessGeometric accuracy
5
Figure 2 AQUA Dx
r a d i o l o g yFuture is Effortless
Product Spec Sheet
AQUATM RADIOLOGY OVERVIEW
FIGURE 2: AQUATM Radiology network diagram describing the software and hardware configuration on the client network.
Users access AQUATM Radiology through a web browser on an AQUATM Radiology Workstation. Users are authenticated either on the AQUATM Radiology Server or via the hospital’s Active Directory system.
Only an AQUATM Radiology Trusted Workstation can execute QA tests that connect to imaging devices.
The Mobile Machine Dashboard is a web application accessed within the client’s private network.
6
iCom Agent AQUATM Radiology iCom Agent
COMPONENT SOFTWARE PROVIDER VERSION
DICOM server
Web Server
Database
Java
CTP
Acumyn
Oracle
Microsoft
Apache Software Foundation
RSNA
1.0
Kit 7 Update 79
2008 R2
7.0.61
2015.09.13
Tomcat
Java SE Development Kit 7 update 79
SQL Server 2008 R2
AQUATM Radiology is developed by Acumyn Inc. (Toronto, Canada).
SOFTWARE INSTALLED WITH AQUATM RADIOLOGY
LEGAL
AQUATM Radiology is not a medical device, nor is it intended for use in the diagnosis, cure, treatment, or prevention of disease.
For American customers: in accordance with the Code of Federal Regulations, Title 21, Sections 800-1299, AQUATM Radiology is not a medical device.
For Canadian customers: AQUATM Radiology is not a medical device as per Medical Device Regulations SOR/98-282.
For European customers: AQUATM Radiology is not a medical device as defined in the Council Directive 93/42/EEC of 14-June-1993 concerning medical devices. AQUATM Radiology is not intended for collection, storage, processing, or analyzing of patient data to support or influence the medical care provided to that patient.
r a d i o l o g yFuture is Effortless
Product Spec Sheet
REGULATIONS
SYSTEM REQUIREMENTS
User credentials can be managed locally by AQUATM Radiology or through the hospital’s Active Directory.
SUPPORTED BROWSERS
Firefox 39.0 or later
Minimum recommended screen resolution is 1024x768. Safari Version: 8.0.7 (10600.7.12) or later
IE 11
Chrome V44.0.2403.125 or later
SERVER OPERATING SYSTEM
Windows Server 2008 R2 Standard 64-bit OS
Windows 7 Professional
SERVER HARDWARE
Intel Xeon CPU E5-2670 @ 2.6 GHz (2 processors)
32 GB DDR4 RAM
AQUATM Radiology software: < 1 GB
Database: 5 GB
Image-Based Tests: 20 GB/year/machine
Disk Space
7