R2E Mitigation Project – Status & Outlook July 15th 2011

(R2E) Mitigation Project: www.cern.ch/r2e Mini-Chamonix, July 15th 2011

Radiation To ElectronicsStatus & Outlook

M. Brugger on behalf of the R2E Project

!!! Many Thanks To Everybody !!!

Snapshot

Page 2: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 20112

OverviewRadiation Levels& Evolution

Observed Equipment Failures

2011/2012 To-Do’s

XmasBreak & Patch-Solutions

Mitigation Plan & Strategy

Page 3: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 20113

Measured & Expected Rad-LevelsWeekly Report

Detailed Analysis

Link1 & Link2

Comparison & Extrapolation

x50

Page 4: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 20114

2011 Operation up to Week 25 (2010 excluded): -> 1fb-1 (nominal: x50 for lumi scaling)

Scaling might be non-linear for areas being dominated by direct losses (& distributions)

Luminosity Dominant

Intensity Dominant

Luminosity Dominant

Luminosity Dominant

Intensity Dominant

Intensity Dominant

Luminosity Dominant

OLD ESTIMATE

Measured & Expected Rad-Levels

Page 5: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 20115

Performed R2E Mitigation ActionsShielding:

P6 (RA63/UA63 and RA67/UA67) (gain ~factor 5-10)UJ22/23/76/88/87 (gain ~factor 10)RR77/73 (gain ~factor 10)US85 Safe-Room (gain ~factor 10)

Relocations:Fire-Control Racks UJ56/76, US85 (safe) RTU relocated from safe room in UJ56/76 (safe) Cryo-relocations/valve replacement in UX85 (safe)UPS from UJ76 (safe)Fire-Detectors: US85, other points prepared (safe)

Preparations:Cabling preparations and Rack Installations: P1, P7, P8

Page 6: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Radiation Levels: Follow-Ups!UX45: Increase of radiation levels in UX45

12 RadMon counts so far

REs: Increase of radiation levels18 RadMon counts so far

ARCs: Increase of radiation levelsvery low radiation so far (<1mGy/week)nominal (expected): few Gy per year

How much will residual gas densities go up?How to scale to nominal operation?

Page 7: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Equipment FailuresSources of Information

eLogBook8:30h meetingsRadWG list (see link)Cryogenics List (see link)QPS analysis/list (see intermediate summary)TE/EPC List (updated log)Emails and discussions

Your observations/input !

!!! NOT AN EASY EXERCISE !!!

Page 8: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Equipment Failures??? Definition of Failure linked to SEE ???One or several (ideally all) of the following conditions:

Failure occurs during beam-on/collisions/losses (source of radiation)Failure is not reproducible in the labFailure signature was already observed during radiation tests (CNRAD and others)Failure frequency increases with higher radiation (hopefully we don’t get there)

Page 9: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Limitations in AnalysisLimitation-1:

SEEs which are not SEEs?Limitation-2:

Hidden failures !(not related to SEEs, caused by 3rd party equipment with indirect impact, e.g. Ethernet Switches)?

Limitation-3: High probability to miss those not causing a dump!

9

Page 10: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Observed SEE Failures

10

How to Scale to Nominal Operation?Luminosity: P1/5 (x50), P8: (x3-5)Energy: P1/5/7/8: (x1.5)Intensity: P7: Losses & Distribution (x ???)Beam-Gas: P1/5/7/8 + ARC @25ns & Scrubbing (x ???)

!!! STILL NOT AN EASY EXERCISE !!!

Except QPS, only failures leading to dump?

G. Spiezia LBOC (link) + Updates (not easy)

Page 11: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201111

Power-Converters & ToleranceParts have been tested at CNRAD

Expected sensitivity ~1x10-8

(= one failure every ~1x108cm2 per converter)

LHC Observationsso far four failures confirmed as SEE(sensitive module: AC/DC part)+ few cases of 2nd failure ‘signature’

New Test-Area H4IRRAD:LHC-like conditions (spectra)About 1 year of nominal LHCwithin one week of testFinal results after the summer!

What will we learn:confirm LHC observationsverify weak links and investigate patch-solutions (important for 2012and 2014/15/16 operation)optimize global mitigation strategy

SPS Beam

Jura SideNorth Area:

Saleve Side

Power-Converter’s are the Key Point for the final

R2E Mitigation Strategy

Page 12: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

What it Means in Reality

12

TEST THIS:

HERE

BEFORE …AND AFTER …

(W)HOW ???DANGEROUS LIQUID:

Page 13: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Equipment Failures

15 16 17 18 19 20 21 22 23 24 250

1

2

3

4

5

Week of operation

Err

ors

pe

r w

ee

k

Low (weekly) statistics, but correlation visible

Page 14: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Roadmap for 2011Detailed radiation field analysis (Monitoring, TLDs, MD)Additional radiation tests (H4IRRAD, CNRAD)Provision/preparation of mitigation actions

xMasBreak (shielding P1, some relocations, preparations)LS1 (shielding P1/5/8, relocations: P1/5/7/8)RadTol Power Converters

TS & xMasBreak improvementsAdditional patch-solutionsEvaluation of additional weak points (P4, REs)R2E Review in November

14

Page 15: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201115

Conclusion2011:

failures will continue to occur but not limit luminosity reach (patches -> 'shadow' of other problems)Continued testing/monitoring/analysis will allow to optimize R2E mitigation measuresR2E Review in November

2012:xMasBreak actions will improve the situationimpact of possible 25ns operation?(residual gas densities in the ARC & P4!)

Page 16: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

THANK YOU…

16

Keeping Track of Cables

Target & Monitoring PeopleCooling

Shielding

AND…

Page 17: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201117

Backup

Page 18: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201118

Mitigation Options

SHIELDINGRELOCATION

CIVIL ENGINEERING

RAD-TOL DESIGN

No Major CE

Improve & Gain TimeSolve & Gain Time

Solve & Remain Flexible

What Can Be Done (in general)

Page 19: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201119

Mitigation Strategy1st Safety Critical

2nd Easy Shielding

3rd Most Sensitive

4th Remaining

Immediate Relocation

“Fast” & Global Improvement

Highest Impact on Operation:(1)Relocation(2)Shielding

(1)Relocation(2)Shielding(3)New Design

Page 20: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201120

IR7 Performed Mitigation ActionsShielding installed: [ECRs: 985313 and 977085]

RR73/77 (we gained ~factor 10 in radiation levels)UJ76 (we gained ~factor 10 for safe-room, 3-4 for the 1st floor)

Relocation of UPS from UJ76 (safe) [ECR: 977085](safety critical at that time!)Relocation of fire control racks (safe)(possible impact on safety not excluded):

UJ76 -> TZ76 [ECR 1126688]

Relocation of EN/EL control equipment (safe) RTU relocated from safe room in UJ76 -> TZ76

Relocation of fire detectors (possible impact on safety redundancy):

Prepared for UJ76 and RR73/77 (see ECR 1126688)

Rack installation & cabling preparations: UJ76 -> TZ76

Page 21: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201121

Mitigation Actions Already DoneShielding installed:

Ducts in P6 (RA63/UA63 and RA67/UA67) (gain ~factor 5-10)UJ22/23 and UJ88/87 (gain ~factor 10)US85 Safe-Room (gain ~factor 10) [ECR: 1053225 ]

Cryo-relocations/valve replacement in UX85 (safe)Relocation of fire control racks (possible impact on safety):

US85, UJ56 [ECR: 1053225 ] (safe)

Relocation of fire detectors (possible impact on safety):US85 (other points prepared) [ECR: 1053225 ] (safe)

Relocation of EN/EL control equipment RTU safe room UJ56 (safe)

Cabling preparations: P1, P7, P8

Page 22: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Possible SEE Failures Observed in 2010

TE/EPC power supply burnout in UA87

Same effect observed in CNRAD SEE is very likely the cause(Streaming through Maze)

CRYO tunnel card SEE in 8L21 Fault in uFip (as observed in CNRAD 2010)SEE confirmed

PXI power supply burnout in UJ16To be confirmed by producer (comparison with CNRAD burnouts)SEE unlikely (early 2010 operation)

QPS Tunnel Card Failures(2x in 9L7 [ions], 2x in 8R8 [inj.], + others)ISO150 -> permanent PM triggerSEE confirmed (EMC has same effect)

VAC power supply burn out In UA23 between maze and duct (TDI losses + TCDI losses )SEE rather unlikely

WIC crate failure in TI8 Observed in 2009Known problem with moderate x-section

QPS tunnel Card Failuresin 9R7 & 9L7

uFip communication lost (2x)SEE confirmed (seen in CNRAD)

CONFIRMED or very LIKELY

NOT CONFIRMED (unlikely)

22

Page 23: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Failures 2011 [Mitigation]Collimation Control UJs@P1 (3x, confirmed) [Soft + Relocation]Cryogenics UJ14/16/56/76 (several confirmed) [Relocation]Biometry UJ14/16 (2x, likely) [Operation + Rel.?]US85 PLCs (Cryo, 3x, confirmed) [Relocation]Power Converters (4x, TE/EPC) [New Develop.]UPS UJ56/US85?(unlikely, but possible) [Relocation]QPS Control UJ14/16 (few, corrector circuits) [Relocation]QPS ISO-150 (many, tunnel & shielded areas) [Soft + New Develop.]uFIP as used in QPS/Cryo (few times, tunnel + shielded areas) [Soft + New Develop.]

Limitation-1: SEEs which are not SEEs?Limitation-2: hidden failures (not related to SEEs, caused by 3rd party equipment with indirect impact, e.g. Ethernet Switches)?

23

Page 24: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Power Converter Failures

24

© TE/EPC

Page 25: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201125

Minimize the number of converter types: Only the LHC60A-08V was specified for a radioactive environment ! 3 other converter types are part now of the radioactive sensitive areas!

LHC POWER CONVERTERs

LHC4..6kA-08V

1-Quadrant

200 Units

LHC120A-10V

4-Quadrant

300 Units

LHC600A-10V

4-Quadrant

400 UnitsLHC60A-

08V4-Quadrant

752 Units

Units : Quantity in all machine (UA, RR, UJ, tunnel)

© V. Montabonnet, Y. Thurel

Page 26: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

IR7 Critical Areas & Equipment

26

Equipment UJ76Fire/ODH control & detectors Cryogenics Instrumentation (Profibus)

AUG control VacuumUPS Beam Television Monitor

Electrical Distribution & Control RamsesRemote-Reset & Timing GSM DiagnosticsAccess System Control Beam Loss Monitors

Power Converter Beam Position Monitors (temporary)Ethernet Optical Fiber

Cooling and Ventilation WorldFip

Less radiation critical equipment Fire/ODH detectos to be relocatedCurrent Lead Heaters ok for the levelsQPS known patch solution

Equipment RR73/77Fire/ODH detectors Beam Position MonitorsPower Converter Cryogenics Instrumentation (FIP)

QPS WorldFipCooling and Ventilation Current Lead Heaters

Power Interlock Electrical Distribution

Power Converters – Big Unknown

Various critical equipments Several tested at CNGS and shown high radiation sensitivityFew cases allow for ‘patch’ solutions

Global Solution Required

Equipment Inventory (EDMS #1092167)

Page 27: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201127

IR7 Radiation: Today?Combined Loss Analysis (BLMs & Injected/Dumped Intensities):

IR3 lost in 2011: ~6E13 protons (per beam)IR7 lost in 2011: ~2E14 protons (per beam)

We’re a factor of ~50x below nominal (~1x1016p/b/y)

Can nominal operation lead to ‘relatively’ higher losses?

Latest Weekly Report (www.cern.ch/r2e)

RR73/77: ~2-3x106cm-2

UJ76: ~1x106cm-2

Nominal Year:RR73/77: ~2x108cm-2

UJ76: ~8x107cm-2

© A. Nordt, A. Thornton

Scaling: x75 (Energy!)

Page 28: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Collimation Review

28

Performed mitigation options

2011/12 Operation

UJ76 relocation

Power-converter tests & R&D for RadTol Dev.

Betatron collimation in IR3

very efficient

not limited by IR7

next step (safety)

high-importanceto judge for RRs

Would provide additional flexibility

Page 29: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

RRs: Power-Converter R&D TE-EPC Planning for Rad Tolerant Converter Project © Y. Thurel

29Link: R2E Power Converter R&D

Page 30: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201130

RRs Additional/Alternative OptionsBetatron Collimation in IR3

No significant SEE impact for IR3Low radiation levels in IR7Additional flexibilityStandard collimators to be added

R&D for Superconducting Links © A. Ballarino et al.

© R. Assmann et al.

Page 31: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Summary (Protons)In 6.02E+15 Dumped 5.82E+15 96.70%Lost in Machine 1.99E+14 3.30%

Of Lost protonsCollisions 2.33E+13 11.73%Elsewhere 1.76E+14 88.27%

LM01 LM02 LM03 RM05RM04RM03 RM06

RR77

RadMon Dcum RthSEU (3V)

MeasuredBeam

contributionSEU (FLUKA)

ExpectedError [%]Stat. only Exp./Mes.

6L7.7LM03S 19846 5 14401 B1 15015 3 1.045L7.7LM02S 19904 3 5253 B1 9765 3 1.864L7.7LM01S 19991 5 2689 B1+B2 3116 6 1.164R7.7RM03S 20045 3 950 B1+B2 401 6 0.425R7.7RM04S 20133 5 18727 B2 13032 4 0.706R7.7RM05S 20208 31 303 B2 962 8 3.17RR77.7RM06S 20241 1 13 B1+B2 17 22 1.33

BLM ratio IR7 / IR3

  Ratio% Loss in

IR7TCSG.A6L7.B1 / TCSG.5L3.B1 3.1 76TCSG.A6R7.B2 / TCSG.5R3.B2 5.6 85

IR7 FLUKA Application Benchmark

>500m

UJ76

TCP TCAP MBW TCS TCLAMQW

Loss-Term (SixTrack [R. Assmann et al.])

FLU

KA

Calc

ula

tion

s

RR73

Assumptions

Normalisation

© K. Roeed

31

2010 Operation

Page 32: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Radiation Levels 2010Source terms, operational conditions as well as monitor readings have to be carefully evaluated

32

VERY GOOD AGREEMENT (given

the underlying uncertainties)

FLUKA Predictio

ns

Operation Assumpti

ons

Rad-Level

Estimate

Monitor Readings

Calibration

Assumptions

Final Values

Tracking/BeamGas/

etc.

Threshold of monitors is

~106!(lower values only by

‘trick’ [big uncertainties!])

Page 33: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201133

2011/2012/Nominal/+++ ???

2010/2011/2012 Radiation Levels

Close to ‘Threshold’Critical Dramatic?!!! Amazing !!!

Page 34: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201134

IP8/TI8 Radiation Detectors

5RM05S

5RM06SPATL8711

PMIL88125RM07S

PMIL8811

5RM08S

Current location not known in full detail of the Radmon and RAMSES positions

© V. Boccone

Large Gradient:4-5 orders

of magnitude

Page 35: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201135

TED Loss: RadMon Downstream© V. Boccone

Page 36: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 201136R2E Mitigation Project – Status & Outlook July 15th 2011

UJ87: Loss on TCDIH.87904© V. Boccone

Page 37: R2E Mitigation Project – Status & Outlook July 15 th 2011 (R2E) Mitigation Project:  Mini-Chamonix, July 15 th 2011 Radiation To Electronics

R2E Mitigation Project – Status & Outlook July 15th 2011

Point-8 Application Benchmark

Detector

Measured dose

(mSv/h) @10.6MHz

Ratio (meas/simu)

PMI8501

(UX85)24.0 1.1

PMI8511

(UX85)120.0 0.8

PAT8511

(US85)36.7 0.6

FLUKA/RAMSES benchmark

FLUKA/RadMon benchmarkDetecto

rRatio

(FLUKA exp/measure)

8LE10S

1.6

8LE07S

2.0

8LE04S

1.6

8LE08S

2.2

FLUKA Simulations provide high energy hadron fluence, dose and 1 MeV Si equivalent in the LHCb cavern according to the Phase-2 shielding implementation proposed in the R2E Project

UW85

US85

UX85

Very good agreement with PMIs and PATs RAMSES detectors RadMons set at 3V more difficult (at low count rates)Significant uncertainties to be considered (thermal neutron contribution, detector geometry, etc…)Uncertainty at least a factor of 2

© M. Calviani

37