quantitative in-situ x-ray diffraction … of portland cement at defined temperatures c. hesse(1),...

7
QUANTITATIVE IN-SITU X-RAY DIFFRACTION ANALYSIS OF EARLY HYDRATION OF PORTLAND CEMENT AT DEFINED TEMPERATURES C. Hesse (1) , F. Goetz-Neunhoeffer (1) , J. Neubauer (1) , M. Braeu (2) , P. Gaeberlein (2) (1) Mineralogy, University of Erlangen-Nuremberg, D-91054 Erlangen, Germany (2) BASF Construction Chemicals GmbH, D-83308 Trostberg, Germany ABSTRACT Investigation into the early hydration of Portland cement was performed by in-situ X-ray diffraction (XRD). Technical white cement was used for the XRD analysis on a D5000 diffractometer (Siemens). All diffraction patterns of the in-situ measurement which were recorded up to 22 hours of hydration at defined temperatures were analyzed by Rietveld refinement. The resulting phase composition was transformed with respect to free water and C-S- H leading to the total composition of the cement paste. The hydration reactions can be observed by dissolution of clinker phases as well as by the formation of the hydrate phases ettringite and portlandite. With increasing temperatures the reactions proceed faster. The formation of ettringite is directly influenced by the rate of dissolution of anhydrite and tricalcium aluminate (C 3 A). The beginning of the main period of hydration is marked by the start of portlandite formation. The experiments point out that a quantitative phase analysis of the cement hydration is feasible with standard lab diffractometers. INTRODUCTION The hydration of ordinary Portland cement (OPC) is a complex process yielding to the hardening of cement paste while forming different hydrate phases. Ettringite (C 3 A•3CS•H 32 ) 1 is formed from anhydrite (CS), C 3 A, and water during the aluminate reaction [1]. The silicate reaction describes the formation of portlandite (CH) and an amorphous calcium silicate hydrate gel (C-S- H) from tricalcium silicate (C 3 S) and water [1]. The composition of C-S-H, especially the Ca/Si- ratio is reported to vary in a large range between 0.5 and 3.0 [2], depending on hydration time and cement type. For the early hydration of OPC a Ca/Si- ratio of 1.7 is assumed with different water content [1,3]. OPC hydration is often analyzed by heat flow calorimetry but this method provides only information about the kinetics without regard to the proceeding reactions. Therefore the advantage of quantitative phase analysis which is widely used in the determination of the phase compositions of dry cements should be used for the investigation of the hydration process. In-situ analysis of cement hydration is usually done by synchrotron X-ray powder diffraction [4,5] but this method is very expensive and cannot work as standard analysis method. Therefore the aim of this investigation was the development of a quantitative in-situ XRD 1 cement nomenclature is used: CCaO, SSiO 2 , AAl 2 O 3 , HH 2 O, S;SO 3 15 Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002 Advances in X-ray Analysis, Volume 52

Upload: lamquynh

Post on 24-Apr-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: QUANTITATIVE IN-SITU X-RAY DIFFRACTION … OF PORTLAND CEMENT AT DEFINED TEMPERATURES C. Hesse(1), F. Goetz-Neunhoeffer(1) , J. Neubauer

QUANTITATIVE IN-SITU X-RAY DIFFRACTION ANALYSIS OF EARLY HYDRATION OF PORTLAND CEMENT AT DEFINED TEMPERATURES

C. Hesse(1), F. Goetz-Neunhoeffer(1), J. Neubauer(1), M. Braeu(2), P. Gaeberlein(2) (1) Mineralogy, University of Erlangen-Nuremberg, D-91054 Erlangen, Germany

(2) BASF Construction Chemicals GmbH, D-83308 Trostberg, Germany

ABSTRACT Investigation into the early hydration of Portland cement was performed by in-situ X-ray

diffraction (XRD). Technical white cement was used for the XRD analysis on a D5000

diffractometer (Siemens). All diffraction patterns of the in-situ measurement which were

recorded up to 22 hours of hydration at defined temperatures were analyzed by Rietveld

refinement. The resulting phase composition was transformed with respect to free water and C-S-

H leading to the total composition of the cement paste. The hydration reactions can be observed

by dissolution of clinker phases as well as by the formation of the hydrate phases ettringite and

portlandite. With increasing temperatures the reactions proceed faster. The formation of ettringite

is directly influenced by the rate of dissolution of anhydrite and tricalcium aluminate (C3A). The

beginning of the main period of hydration is marked by the start of portlandite formation. The

experiments point out that a quantitative phase analysis of the cement hydration is feasible with

standard lab diffractometers.

INTRODUCTION

The hydration of ordinary Portland cement (OPC) is a complex process yielding to the hardening

of cement paste while forming different hydrate phases. Ettringite (C3A·3CS·H32)1 is formed

from anhydrite (CS), C3A, and water during the aluminate reaction [1]. The silicate reaction

describes the formation of portlandite (CH) and an amorphous calcium silicate hydrate gel (C-S-

H) from tricalcium silicate (C3S) and water [1]. The composition of C-S-H, especially the Ca/Si-

ratio is reported to vary in a large range between 0.5 and 3.0 [2], depending on hydration time

and cement type. For the early hydration of OPC a Ca/Si- ratio of 1.7 is assumed with different

water content [1,3]. OPC hydration is often analyzed by heat flow calorimetry but this method

provides only information about the kinetics without regard to the proceeding reactions.

Therefore the advantage of quantitative phase analysis which is widely used in the determination

of the phase compositions of dry cements should be used for the investigation of the hydration

process. In-situ analysis of cement hydration is usually done by synchrotron X-ray powder

diffraction [4,5] but this method is very expensive and cannot work as standard analysis method.

Therefore the aim of this investigation was the development of a quantitative in-situ XRD

1 cement nomenclature is used: C�CaO, S�SiO2, A�Al2O3, H�H2O, S;¯�SO3

15Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002Advances in X-ray Analysis, Volume 52

Page 2: QUANTITATIVE IN-SITU X-RAY DIFFRACTION … OF PORTLAND CEMENT AT DEFINED TEMPERATURES C. Hesse(1), F. Goetz-Neunhoeffer(1) , J. Neubauer

This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website – www.dxcicdd.com

ICDD Website - www.icdd.com

Advances in X-ray Analysis, Volume 52

Page 3: QUANTITATIVE IN-SITU X-RAY DIFFRACTION … OF PORTLAND CEMENT AT DEFINED TEMPERATURES C. Hesse(1), F. Goetz-Neunhoeffer(1) , J. Neubauer

analysis of early cement hydration with standard lab diffractometers. Former investigations of

cement hydration have shown that the temperature has a strong influence on the reaction kinetics

[6,7]. Hence temperature during analysis has to be controlled.

MATERIALS AND METHODS

Commercial white cement (WCem) with a mineralogical composition given in Tab. 1 was used

for the experiments. Cement and water were weighted according to a water to cement (w/c) ratio

of 0.5. All materials and tools needed for the sample preparation were thermally equilibrated at

the measurement temperature. For the in-situ XRD analysis a custom made sample holder was

used which controls the temperature during the measurement [8]. The temperature is set

thermoelectrically by a Peltier element below the sample which is controlled by the software

MAETRE (Mesicon). Cement and water were mixed by external stirring for 1 minute and then

the paste was filled into the sample holder. The surface of the paste was smoothed and then

covered by a 7.5 µm thick Kapton film. The diffraction patterns were recorded by a D5000

diffractometer (Siemens) equipped with a SolX detector (Bruker). CuKá radiation was used at a

voltage of 40 kV and a current of 30 mA. The measurements were carried out in a 2è range of

7°�41° with a step width of 0.024° and 0.6 s time per step. 88 patterns were recorded within 22

hours. The measurement of one diffraction pattern lasts approximately 15 minutes. Therefore the

Rietveld result reflects an average of these 15 minutes.

Tab. 1: Phase composition of used white cement. Values are given in wt.-%.

C3S C2S C3A anhydrite bassanite portlandite calcite

63.8 20.5 4.0 2.9 1.6 3.0 4.2

The quantitative analysis with the Rietveld method was done with the software Topas 3.0

(Bruker). Three successive measurements of one sample were refined jointly leading to an

average phase composition between these three measurements. This method is practicable due to

the slow changes in phase composition during hydration and leads to more stable values of the

phase development. Refined parameters are lattice parameters and crystallite size for the hydrate

phases as well as preferred orientation for portlandite, ettringite, C3S, and anhydrite. The lattice

parameters, microstrain, and crystallite size for C3S, C3A, C2S, calcite, and anhydrite were

determined by Rietveld refinement of dry cement. These parameters were not refined during

analysis of in-situ patterns because they underwent no changes during hydration. Additionally, a

peak phase was used for the simulation of the diffuse diffraction maximum caused by the Kapton

film (Fig. 1). The peak phase was not refined during Rietveld analysis of the in-situ

Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002 16Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002Advances in X-ray Analysis, Volume 52

Page 4: QUANTITATIVE IN-SITU X-RAY DIFFRACTION … OF PORTLAND CEMENT AT DEFINED TEMPERATURES C. Hesse(1), F. Goetz-Neunhoeffer(1) , J. Neubauer

measurements. The same starting refinement model was used for all samples and ranges. Besides

the XRD analysis, the cement hydration was investigated by isothermal heat flow calorimetry.

°2Theta Cu Kalpha

40353025201510

Cou

nts

120

100

80

60

40

20

0

-20

-40

-60

Fig. 1: Peak phase of the diffuse diffraction maximum caused by Kapton film. The pattern of the Kapton film (circles) was recorded by the preparation of the film on a silicon single crystal sample carrier measured under the same conditions like the cement paste.

RESULTS AND DISCUSSION

The diffraction patterns displayed in Fig. 2 reflect the changes in the phase composition of the

cement paste with the help of a level plot.

Fig. 2: Level plot of in-situ XRD measurement of white cement at 23 °C hydrated with w/c = 0.5

The Rietveld analysis results in the phase composition of all crystalline phases in the cement

paste. But because of free water and the forming of an amorphous C-S-H phase the total phase

composition of the cement paste has to be calculated. The C-S-H content is calculated from the

Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002 17Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002Advances in X-ray Analysis, Volume 52

Page 5: QUANTITATIVE IN-SITU X-RAY DIFFRACTION … OF PORTLAND CEMENT AT DEFINED TEMPERATURES C. Hesse(1), F. Goetz-Neunhoeffer(1) , J. Neubauer

formation of portlandite in accordance to Eq. 1 for OPC. Afterwards, the content of free water

(Hfree) is calculated with respect to the w/c-ratio and bonded water (Hbond) in the hydrate phases

by summation of all dry phases, bonded water, and free water to a total sum of 150 wt.-%

depending on the used w/c-ratio. The process map of the calculation procedure is given in Fig. 3.

The following discussion is based on the transformed values.

Eq. 1: C3S + 3.9 H C1.7SH2.6 + 1.3 CH

C-S-Hwet

C-S-Hwet

C-S-Hdry

Hbond Hfr

ee

C-S-Hdry

0 wt.-%

100 wt.-%

150 wt.-%(dependingon w/c-ratio)

calculation steps

Hfr

ee

Fig. 3: Calculation procedure for the determination of the phase composition of the cement paste. Hbond�crystalline bonded water,

Hfree�free water in the paste

0 2 4 6 8 10 12 14 16 18 20 220123456789

1011121314151617

C3Aph

ase

cont

ent [

Ma.

-%]

time [h]

ettringite

Fig. 4: Phase development of ettringite and C3A at 23 °C. Black lines are the smoothing

result with a Fourier function.

0 2 4 6 8 10 12 14 16 18 20 220

1

2

3

4

5

6

7

8

9

20304050

0123456789

20304050

0.0 0.5 1.00

10

20

30

40

50

time [h]

heat

flow

[mW

/gce

men

t]

time [h]

white cementw/c = 0.5, T = 23 °C

initial period

main period

initial period

Fig. 5: Measured heat flow for the hydration of white cement at 23 °C with w/c = 0.5. The initial

period is additionally plotted on the right side.

Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002 18Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002Advances in X-ray Analysis, Volume 52

Page 6: QUANTITATIVE IN-SITU X-RAY DIFFRACTION … OF PORTLAND CEMENT AT DEFINED TEMPERATURES C. Hesse(1), F. Goetz-Neunhoeffer(1) , J. Neubauer

0 2 4 6 8 10 12 14 16 18 20 220

2

4

6

8

10

phas

e co

nten

t [w

t.-%

]

time [h]

WCem w/c = 0.5portlandite phase development

16 °C 23 °C 30 °C 37 °C

B

The values for the phase evolution of the hydrate and the cement phases, respectively, show only

low scatter (Fig. 4) with exception of minor phases like C3A (cubic+orthorhombic) and

anhydrite. Quantification of C3A is difficult due to an overlapping of the main analytic reflections

with á´-C2S and determination of anhydrite content is complicated by a preferred orientation in

(020) direction.

The cement hydration starts directly after adding water to cement. Within the first 30 minutes a

part of C3A and of the sulfate carrier (bassanite and anhydrite) is dissolved rapidly resulting in a

strong increase in ettringite content. This very fast process leads to high heat flow during the

initial period of hydration (Fig. 5). The content of ettringite increases within the first 0.5 h from

0 wt.-% up to 4 wt.-% depending on temperature.

0 2 4 6 8 10 12 14 16 18 20 22-2

0

2

4

6

8

10

12

14

16

18

phas

e co

nten

t [w

t.-%

]

time [h]

WCem w/c = 0.5ettringite phase development

16 °C 23 °C 30 °C 37 °C

A

Fig. 6: Phase content development for ettringite (A) and portlandite (B) at different temperatures. Curves are the average of two measurements. The ettringite formation rate in the initial period decreases with increasing temperature due to the

lower solubility of bassanite with increasing temperature. At 37 °C the formation of ettringite is

slower than at 23 °C in the first 0.5 hours. But with ongoing hydration the formation of ettringite

runs faster with increasing temperatures until the content reaches its maximum (Fig. 6-A). At

23 °C the ettringite content shows a stronger increase around 11 hours linked with second heat

flow maximum in the main period of hydration. Anhydrite is dissolved in Phase I whereas the

content of C3A decreases very slowly (Fig. 7). After the anhydrite is nearly dissolved a stronger

decrease in C3A content is observed connected with an increase in ettringite content (Phase II).

The determination of the point of complete dissolution of anhydrite is difficult due to the low

phase content close to the quantification limit and the detection limit, respectively.

Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002 19Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002Advances in X-ray Analysis, Volume 52

Page 7: QUANTITATIVE IN-SITU X-RAY DIFFRACTION … OF PORTLAND CEMENT AT DEFINED TEMPERATURES C. Hesse(1), F. Goetz-Neunhoeffer(1) , J. Neubauer

The silicate reaction is marked by the phase development of portlandite (Fig. 6-B). With

increasing temperature the start of the portlandite formation occurs earlier. The C3S content

decreases after the start of the silicate reaction at the same time as portlandite increases.

0 2 4 6 8 10 12 14 16 18 20 220.00.51.01.52.02.53.03.5

5

10

15

20Phase II

phas

e co

nten

t [w

t.-%

]

time [h]

WCem w/c = 0.5T = 23 °C

C3A

anhydrite ettringite

Phase I

Fig. 7: Interrelationship between the dissolution of anhydrite and C3A, respectively, and the formation of ettringite. Curves are the average of two measurements.

CONCLUSION

The method of quantitative in-situ XRD analysis is a workable tool for a standard investigation of

the early hydration of ordinary Portland cement. This method provides also the possibility for an

investigation of the interaction between cement and organic additives.

REFERENCES

[1] Taylor, H. F. W., Cement Chemistry; Academic Press: London, 1990.

[2] Richardson, I. G., Cement and Concrete Research, 2008, 38, 137-158.

[3] Allen, A. J.; Thomas, J. J.; Jennings, H. M., Nature Materials, 2007, 6, 311-316.

[4] Christensen, A. N.; Scarlett, N. V. Y.; Madsen, I. C.; Jensen, T. R.; Hanson, J. C., Dalton

Transactions, 2003, 1529-1536.

[5] Merlini, M.; Artioli, G.; Cerulli, T.; Cella, F.; Bravo, A., Cement and Concrete Research,

2008, 38, 477-486.

[6] Hesse, C.; Degenkolb, M.; Gaeberlein, P.; Goetz-Neuhoeffer, F.; Kutschera, M.;

Neubauer, J.; Schwarz, V., Tagung der GDCh-Fachgruppe Bauchemie, 27-28 September

2007 in Siegen, 2007, 37, 213-220.

[7] Kjellsen, K. O.; Detwiler, R. J., Cement and Concrete Research, 1992, 22, 112-120.

[8] Hesse, C.; Degenkolb, M.; Gäberlein, P.; Götz-Neunheoffer, F.; Neubauer, J.; Schwarz,

V., Cement International, 2008, 68-78.

Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002 20Copyright ©JCPDS-International Centre for Diffraction Data 2009 ISSN 1097-0002Advances in X-ray Analysis, Volume 52