putting a forensic eye on mass...

28
The world leader in serving science Claudio De Nardi Thermo Fisher Scientific - Sales Support Expert LSMS Clinical and Toxicology Putting a Forensic Eye on Mass Spectrometry

Upload: lamthien

Post on 26-Mar-2018

218 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

The world leader in serving science

Claudio De Nardi Thermo Fisher Scientific - Sales Support Expert LSMS Clinical and Toxicology

Putting a Forensic Eye on Mass Spectrometry

Page 2: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

2

Clinical and Forensic - A Lot of Overlapping Areas

NewBorn Screening Endocrinology

TDM (Immunosuppressants, Vitamin D, Antiepileptics, etc)

Trace Analysis Explosives

(non biological)

FORENSIC

TOXICOLOGY

CLINICAL

CLINICAL TOXICOLOGY

FORENSIC TOXICOLOGY

TDM (Abuse of Drugs, Alcohol,

Benzodiazepines, etc)

Abuse of Drugs Benzodiazepines, etc

POSTMORTEM

Environmental Toxicology Occupational Health

Antidoping

Page 3: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

3

Customers Expectations/Requirements

I want to do quantitation

I want to perform targeted screening

with database/library searching

I want to identify unknown

and need retrospective analysis

• I want to be able to screen samples using a database of at least 1000 compounds

• I want to be able to use offline and online spectral libraries

• I want to search for totally unknown compounds in addition to targeted screening

• I need to retrospectively interrogate a sample searching for new/unexpected compounds

• I want ultimate sensitivity

• I want to quantify small concentrations in heavy matrices

• I want to quantify more than 1000 compounds in a run

Page 4: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

4

Screening Approaches – Some Definitions

Unknown Screening

“Search for the rest”

Targeted Screening

“Search for what you

know”

Untargeted Screening

“Search for what you

suspect”

• Compound search after targeted acquisition using a specific list of compounds

• Detection parameters need to be numerous and selective to avoid false positives

• Compound search following acqusition based on most intense signals NOT on a list of compounds

• Identification based on compound databases and/or spectral libraries

• Search of compounds with an totally untargeted acquisition

• Putative identification typically followed by structural elucidation

Page 5: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

5

Screening Workflow

• Related to sample matrix (urine, blood, serum, plasma, etc)

• TraceFinder

• Compound

databases

• Spectral libraries

• mzCloud

• Compound Discoverer

• Ion Trap

• Triple Quadrupole

• High Resolution MS

Sample Preparation Data acquisition Data Processing

Filtration Dilute-and-Shoot

Protein Precipitation Solid Phase Extraction TurboFlow

Liquid Liquid Extraction

Supported Liquid Extraction

CLE

AN

EA

SY

Page 6: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

6

Front Ends and Sample Preparation

Liquid Chromatography

TurboFlow

Paperspray

• Require offline sample preparation

• Suitable for multi-channel solutions

• Require minimal or no sample preparation

• Suitable for multi-channel solutions

• NO sample preparation

• Simple to use

• Fast

Ultimate 3000 Flexibility

Vanquish High-end UHPLC

Transcend II Flexibility

Prelude Robustness

Velox 360 Simplicity

Page 7: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

7

TurboFlow for Online Sample Extraction

• Online sample extraction that adds less than 2 minutes to the normal LC runtime • Offline sample extraction takes hours!

• Allows for the direct injection of complex matrices

• A cleaner sample reaches the mass spec • less background noise → better sensitivity • longer LC column lifetime • cleaner mass spec → less routine cleaning

• You can inject more (up to 100µL) • better sensitivity

Page 9: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

9

Paperspray on TSQ Quantiva – DoA Quantification in Urine

• LOQs in the 0.5 to 50 ng/mL • LODs in the 0.5-1 ng/mL • No sample preparation • No chromatography

amphetamineY = 0.060314+0.00694195*X R^2 = 0.9098 W: 1/X

0 500 1000 1500 2000 25000

5

10

15

Are

a R

atio

cocaethyleneY = 0.000134274+0.00128168*X R^2 = 0.9958 W: 1/X

0 500 1000 1500 2000 25000

1

2

3

Are

a R

atio

cocaineY = 0.00086511+0.00260058*X R^2 = 0.9923 W: 1/X

0 500 1000 1500 2000 25000

2

4

6

Are

a R

atio

methamphetamineY = 0.00628846+0.010073*X R^2 = 0.9967 W: 1/X

0 500 1000 1500 2000 25000

5

10

15

20

25

Are

a R

atio

PCPY = 0.00805257+0.00922576*X R^2 = 0.9954 W: 1/X

0 500 1000 1500 2000 25000

5

10

15

20

25

Are

a R

atio

amitriptyline Y = 0.146009+0.0161053*X R^2 = 0.9870 W: 1/X

0 500 1000 1500 2000 2500 0

10

20

30

40

Are

a R

atio

temazepamY = 0.0262972+0.00528053*X R^2 = 0.9802 W: 1/X

0 500 1000 1500 2000 25000

5

10

Are

a R

atio

Amitriptyline Amphetamine Cocaethylene

Cocaine Codeine

Methamphetamine PCP

Temazepam

Page 10: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

10

Mass Spectrometers – A Leading Portfolio

HR/AM

MS, MSn

Appl

ied

Mar

kets

Research

Markets

Non-targeted Analysis

Targeted Analysis

Quantitative Qualitative

• Biomarker Discovery • Proteomics • Metabolism

• Metabolomics • Proteomics • Bioanalysis

• Food Safety • Environmental • Clinical/Toxicology

• Metabolomics • PTM Analysis • Lipidomics

Transform Your Science

Ion Traps Triple Quads

Tribrid Orbitrap MS

Exactive Series MS

Page 11: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

11

Triple Quadrupoles for Targeted Screening and Quantitation

TSQ Endura Extreme Quantitative Value

• Best-in-class performance

• Unprecedented usability

• Exceptional robustness

TSQ Quantiva Extreme Quantitative Performance

• Attogram sensitivity

• Unprecedented usability

• Exceptional robustness

Chromatogram for

Quantitation

Chromatogram for

Confirmation

Internal Standard

Ion Overlay

Page 12: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

12

Triple Quadrupoles for Quantitation

• Quantitation of 72 Drugs of Abuse on Urine on TSQ Quantiva • Simply dilute-and-shoot • Polarity switching • One SRM for quantitation and one or two for confirmation • Calibration range 5 to 5000 ng/mL

QC %RSD QCA 1.4

QCB 2.6

QUANTIFIER QUALIFIER

Page 13: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

13

Why Q Exactive and MS for Forensic Labs?

Affordable Focus version • Price comparable to high end Triple Quad

Versatile lab of the future • Targeted screening • Untargeted screening • Unknown screening • Quantitative confirmation

Ultimate performance • High sensitivity • High selectivity • High Resolution & Mass Accuracy • Polarity switching

Ease of use • Simple calibration, holds for days • No need for optimization • No compound-specific setup • Robust platform, low maintenance

Your High Resolution Accurate Mass lab of the future

Page 14: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

14

Resolution – Q Exactive vs. Q-Tof

0

50000

100000

150000

200000

250000

300000

0 100 200 300 400 500 600

Res

olut

ion

m/z

Q Exactive

Q-Tof Vendor S

Q-Tof Vendor A

Q-Tof Vendor B

Page 15: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

15

0

100000

200000

300000

400000

500000

1955 1965 1975 1985 1995 2005 2015

Orbitrap Tof / QTof

Race for Resolution – Q Exactive vs. Q-Tof

Year

Res

olut

ion

Bendix Tof

LTQ Orbitrap

Exactive Series

Orbitrap Elite

Orbitrap Fusion

First Q-Tof

QExactive Plus

Page 16: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

16

Benefits of Using Q Exactive for Screening

Resolving power Separate target compounds from interference

Mass stability and mass accuracy

Calibration maintained for days to weeks Unrivaled scan to scan mass accuracy and precision

Fast polarity switching

Quick positive-negative switch maintaining accurate mass/charge determination

No trade-off between resolution and sensitivity Both resolution and sensitivity are retained

Minimum scan to scan variance Excellent signal/noise, no need for averaging

Experiment flexibility Easy to use, a plug and play device

Page 17: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

17

Screening Approach Using a Q Exactive

Fragmentation positive

R = 17.500

FullMS negative

R = 70000

Fragmentation negative

R = 17.500

FullMS positive

R = 70000

Fragmentation types: 1. “Confirmational MS2” for targeted screening

Triggers all compounds of a specific list 2. “Discovery MS2” for untargeted screening

Triggers compounds having the highest intensity 3. “AIF” or “vDIA” MS2 for unknown screening

Fragments everything

Page 18: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

18

TraceFinder Software for Data Acquisition and Processing

Fill with Picture or graphic

Fill with Picture or graphic

Routine Quantitation Targeted and Untargeted

Screening Unknown Screening

• Rugged and robust quantitation for multiple markets, across LC and GCMS systems

• Provides multiple forms of confirmation for targeted screening applications (spectral library, MS/MS2 database, isotopic pattern confirmation)

• Allows for screening for unknowns in conjunction with quan or targeted screening

Providing a complete quantitation and screening workflow for routine applications

Fill with Picture or graphic

Page 19: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

19

TraceFInder WorkFlow for Targeted / Untargeted Screening

Further confirms based on mass of fragments reported in the database 5

Compares theoretical and experimental mass spectrum of the parent using a specific spectral library 4

Identifies chromatographic peaks based on parent mass from a specific database 1

Confirms identification based on retention time in the database 2

Compares theoretical and experimental isotopic pattern for the parent 3

Page 20: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

20

TraceFinder and Targeted / Untargeted Screening

• multiple forms of confirmation: spectral library, MS/MS2 database, isotopic pattern confirmation

Page 21: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

21

TraceFinder and Targeted / Untargeted Screening

• multiple forms of confirmation: spectral library, MS/MS2 database, isotopic pattern confirmation

Page 22: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

22

TraceFinder and Targeted / Untargeted Screening

• multiple forms of confirmation: spectral library, MS/MS2 database, isotopic pattern confirmation

Page 23: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

23

TraceFinder and Unknown Screening

Confirm obtained ChemSpider hit by comparing theoretical fragmentation to experimental fragmentation 5

Search proposed molecular formulas with ChemSpider databases 4

Detect all chromatographic peaks above user specified threshold 1

Identify detected peaks using local database 2

For peaks not identified in step #2 propose molecular formula based on accurate mass and isotopic pattern 3

Page 24: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

24

Example of a hit from Unknown Screening

Unknown peak m/z 166.1224

C10H16ON C4H17N5P

ChemSpider Search Pholedrine Ephedrine Pseudoephedrine 3-(Diethyloamino) phenol 4-(Butyloamino) phenol

TraceFinder Identification

MassFrontier Confirmation

50 60 70 80 90 100 110 120 130 140 150 160 170 180

0

13

25

38

50

63

75

88

100148.1119

91.0546

115.0543

117.0699133.0885

56.0502

132.080865.0392

70.0658 104.062278.0469 95.049653.0392 166.1225 175.454562.0037

NH•

N

N•

NH

50 60 70 80 90 100 110 120 130 140 150 160 170 180

0

13

25

38

50

63

75

88

100148.1119

91.0546

115.0543

117.0699133.0885

56.0502

132.080865.0392

70.0658 104.062278.0469 95.0496166.122553.0028 175.454562.0037

N 2H •

NH

NH H

N•

H

Isomers

50 60 70 80 90 100 110 120 130 140 150 160 170 180

0

13

25

38

50

63

75

88

100148.1119

91.0546

115.0543

117.0699133.0885

56.0502

132.080865.0392

70.0658 104.062278.0469 95.0496166.1225 175.4545

N

N•

N

•N

3-(Diethylamino) phenol 4 fragments

Theoretical vs. experimental fragmentation

NH

OH

NH

OHN

OH

Ephedrine 7 fragments

Pholedrine 7 fragments

Page 25: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

25

Database and Spectral Library of compounds of interest to the clinical research and forensic toxicology communities: • Prescription drugs • Natural and industrial toxins • Drugs of abuse • Drugs of interest for monitoring research • Performance enhancing drugs

An updated version will be available later this year with 4000 compounds and metabolites

The Importance of Databases and Spectral Libraries

Page 26: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

26

MzCloud

4,427 compounds - 7,309 trees - 1,066,072 spectra

https://www.mzcloud.org/

• A novel mass database / library of MS/MS and MSn spectra (R = 140.000 @ m/z 200)

• Structural info for compounds even if they are not represented in the library through identification of substructures

• Multi-energy, multi-fragment level, Multi-fragment technique

• Open consortium to establish a large public domain library which our software will link to

Page 27: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

27

Compound Discoverer 2.0

TraceFinder

Targeted Profiling

m/z Cloud

Compound Identification

Compound Discoverer

Untargeted Discovery

Complete small molecule research and structure identification in a Next Generation

platform

Page 28: Putting a Forensic Eye on Mass Spectrometrytools.thermofisher.com/content/sfs/brochures/PP-Forensic-Eye-Mass... · Putting a Forensic Eye on Mass Spectrometry . 2 . ... Solid Phase

28

Compound Discoverer 2.0

• Unknown compound detection

• Search ChemSpider

• Automatic background filtering • Composition prediction

• Mass list search • Pattern Scoring • Search mzCloud