Product Specifications
PSS 2A-1Z11 APressure Sealsfor Use with I/A Series® Pressure Transmitters
Pressure seals are used with the I/A Series Pressure Transmitters when it is necessary to keep the transmitter isolated from the process. A sealed system is used for a process fluid that may be corrosive, viscous, subject to temperature extremes, toxic, sanitary, or tend to collect and solidify.
FEATURES• Selection of flanged level or flanged remote
mount seals with flush or extended diaphragms. Also recessed diaphragm seals for direct or remote mount with flanged, in-line saddle weld or threaded process connections.
• Sanitary direct or remote mount diaphragm seals offered that meet FDA requirements. Sanitary ends secured to process pipe or tank spud with Tri-Clover® Tri-Clamps®.
• FDA approved Neobee® fill fluid for sanitary applications.
• Flanged seals with ANSI® or BS/DIN carbon or stainless steel flanges in many sizes and ratings.
• Seals with threaded process connections from 1/4 to 1 1/2 NPT.
• In-line, saddle weld seals for 3- or 4-inch (and larger) process pipes.
• Numerous seal sizes available depending on the seal model selected.
• Diaphragms available flush with the flange face; and also available with extensions for flush mounting with inside surface of the tank.
• Capillary lengths from 1.5 to 9 m (5 to 30 ft) for remote mount applications. Capillary is 316 ss with flexible armor, and is available with or without a protective coating.
• Carbon steel, 316L ss, highly corrosion-resistant Hastelloy® C276, Titanium, Monel®, Nickel, and Inconel® are offered as diaphragm materials consistent with the seal configuration selected.
• Fill fluids accommodate process temperatures up to 204°C (400°F) for sanitary and direct connect seals, and up to 304°C (580°F) for remote capillary connected seals.
PSS 2A-1Z11 APage 2
GENERAL PRESSURE SEAL SPECIFICATIONS
INTRODUCTION
Sealed measurement systems, comprising the transmitter sensing element, pressure seal, and connecting tubing (as applicable), are evacuated and filled with an appropriate fill fluid that transmit pressure changes. A pressure seal assembly can be for flanged level applications, direct connected to the transmitter, or remote mounted using an interconnecting capillary.
SELECTION OF PROCESS CONNECTIONS WITH DIRECT CONNECT OR REMOTE MOUNT SEALS
Direct connect or remote mount seals are offered with flanged, threaded, or in-line welded process connections. See Tables 2 and 3 for seal models.
SANITARY SEALS
Sanitary seals are used in food and dairy product applications and meet FDA and United States Public Health Service, Dairy Industry Committee requirements. Tri-Clamps are used to secure the end connection to the process or tank spud.
FLUSH DIAPHRAGM SEALS
These seals are offered with flanged and sanitary process connections. They minimize pockets or cavities where process liquid can collect, and are available in many corrosion resistant materials, including 316L ss, Hastelloy C276, and Tantalum.
RECESSED DIAPHRAGM SEALS
Recessed diaphragm seal assemblies are available in flanged, threaded, and in-line weld configurations. Numerous process-wetted metal selections are offered. With the flanged configuration, nonmetallic PVC and glass-filled Teflon® are also offered for users who are not concerned with a pressure derating to 1030 kPa (150 psi).
EXTENDED DIAPHRAGMS
Flush seals with flanged process connections can be provided with extended diaphragms. This allows the sensing diaphragm to extend through the mounting nozzle and be flush with the inside surface of the tank, eliminating pockets or cavities. Various diaphragm materials and extension lengths up to 230 mm (9 in) are offered, depending on the seal model selected.
REMOTE MOUNT SEAL ORIENTATION TO MATCH APPLICATION REQUIREMENTS
• Dual Seal Version - Balanced• Single Seal - High Pressure Side• Single Seal - Low Pressure Side
REDUCED TEMPERATURE EFFECT
Optimum temperature performance is achieved when both the seal diaphragm stiffness and system fill fluid volume are at their least (see Optimized Capillary Selection paragraph below). Larger diaphragms have lower stiffness and are therefore less affected by temperature. With small pressure measurement spans, it is best to select the largest diaphragm size available.
OPTIMIZED CAPILLARY SELECTION
With remote seal(s), capillary internal diameter must be small to reduce fill volume, but large enough for adequate speed of response. Capillaries for remote seal(s) are available in various lengths and several internal diameters. The selections allow optimizing temperature performance while maintaining adequate speed of response. Capillaries are offered with 300 Series stainless steel armor, and also coated armor, for protection against damage.
CHOICE OF FILL FLUIDS TO MEET PROCESS REQUIREMENTS
When selecting a seal fill fluid, the first considerations are temperature capability of the fluid and compatibility with the process in the event of diaphragm failure. Several silicone fluids are offered that cover various temperature ranges. For processes with strong oxidizing agents such as chlorine or oxygen, Fluorinert fill should be selected. Fluorinert is also suitable for extreme cold temperatures. For sanitary applications, Neobee M20 fill is offered.
PRESSURE SEAL ORDERING INSTRUCTIONS
These pressure seals are used with the I/A Series Pressure Transmitters. Although the seal(s) is(are) shipped assembled to the transmitter, it(they) must be ordered separately. Each transmitter Model Code has a Structure Code selection, which defines whether a transmitter is to be ordered without seals, with remote mount seals, or with direct connect seals. Table 3 identifies which pressure seals can be used with which transmitter. Table 4 at the end of this document identifies the applicable transmitter PSS.
After making the required Structure Code selection in the transmitter Model Code, the user then selects the applicable seal Model Number(s) from this document.
Therefore, a transmitter with seals comprises both a Transmitter Model Number and Seal Model Number(s). Ordering instruction examples are shown further in this document.
PSS 2A-1Z11 APage 3
GENERAL PRESSURE SEAL SPECIFICATIONS (Cont.)
HIGH PERFORMANCE
Refer to the Performance Data section at the end of this document for representative temperature and response characteristics with different diaphragms, fill fluids, and capillary dimensions.
FILL FLUID PRESSURE-TEMPERATURE LIMITS AND SPECIFIC GRAVITIES
Figure 1 shows the relationship between Minimum Allowable Absolute Pressure versus Process Temperature for the various fill fluids used with the
pressure seals. Table 1 lists the specific gravities of the various pressure seal fill fluids used.
Figure 1. Maximum Allowable Pressure vs. Process Temperature - Fill Fluids
Table 1. Fill Fluid Specific Gravities
Fill Fluid Specific Gravity
DC 200 Silicone,10 cSt 0.93 @ 25°C (77°F)FC77 Fluorinert 1.77 @ 25°C (77°F)DC 200 Silicone, 3 cSt 0.89 @ 25°C (77°F)DC 704 Silicone 1.07 @ 25°C (77°F)Neobee M20 0.92 @ 25°C (77°F)
1000
100
10
1
0.1
1000
100
10
1
0.1-200 -100 0.0 100 200 300 400 500 600 700
-100 -50 0.0 50 100 150 200 250 300 350
TEMPERATURE, ˚F
AB
SO
LUT
E P
RE
SS
UR
E, m
mH
g (t
orr)
AB
SO
LUT
E P
RE
SS
UR
E, m
mH
g (t
orr)
TEMPERATURE, ˚C
A
B D
C
E
E
CDB
A
LEGEND
A = FLUORINERT FC77
B = DC200 SILICONE 3cST
C = NEOBEE M20
D = DC200 SILICONE 10 cST
E = DC704 SILICONE
A = FLUORINERT FC77
B = DC200 SILICONE 3cST
C = NEOBEE M20
D = DC200 SILICONE 10 cST
E = DC704 SILICONE
LEGEND
PSS 2A-1Z11 APage 4
GENERAL PRESSURE SEAL SPECIFICATIONS (Cont.)
(a) Used with IDP10 and IGP20 Transmitter only.(b) Used with IAP10 and IGP10 Transmitters only.
(a) For applicable transmitter PSSs, see Table 4 at end of this document.
(b) Pressure Seal models are shown with an abbreviated code; all seal codes have a PS prefix; for example, FLT is really PSFLT.
Table 2. Pressure Seals Used with I/A Series Pressure Transmitters
Direct Connect Pressure Seal Assemblies
Seal Model Seal Description Process ConnectionsPSFLT (a) Flanged, Direct Connect (Flanged Level), Flush
or Extended DiaphragmANSI Class 150/300/600 flanges and BS/DIN PN 10/40, 10/16, 25/40 flanges
PSFAD (b) Flanged, Direct Connect, Recessed Diaphragm ANSI CLass 150, 300, 600, 1500 flangesPSTAD (b) Threaded, Direct Connect, Recessed Diaphragm 1/4, 1/2, 3/4, 1, or 1 1/2 NPT internal threadPSISD (b) In-Line Saddle Weld, Direct Connect, Recessed
DiaphragmLower housing of seal is in-line saddle welded to nominal 3- or 4-inch (and larger) Pipe
PSSCT Sanitary, Direct Connect (Level Seal), Flush Diaphragm
Process Connection to Sanitary Piping with 2- or 3-inch Tri-Clamp
PSSST Sanitary, Direct Connect (Level Seal), Extended Diaphragm
Process Connection to 2-in Mini Spud or 4-in Standard Spud; Tri-Clamp
Remote Mount, Capillary-Connected Pressure Seal Assemblies
Seal Model Seal Description Process ConnectionsPSFPS Flanged, Remote Mount, Flush Diaphragm ANSI Class 150/300/600 flanges and
BS/DIN PN 10/40 flangesPSFES Flanged, Remote Mount, Extended Diaphragm ANSI Class 150/300/600 flanges and
BS/DIN PN 10/40, 10/16, 25/40 flanges PSFAR Flanged, Remote Mount, Recessed Diaphragm ANSI Class 150/300/600/1500 flangesPSTAR Threaded, Remote Mount, Recessed Diaphragm 1/4, 1/2, 3/4, 1, or 1 1/2 NPT internal threadPSISR In-Line Saddle Weld, Remote Mount, Recessed
DiaphragmLower housing of seal is in-line saddle welded to nominal 3- or 4-inch (and larger) Pipe
PSSCR Sanitary, Remote Mount, Flush Diaphragm Process Connection secured with a Tri-Clamp to a 2- or 3-inch pipe
PSSSR Sanitary, Remote Mount, Extended Diaphragm Process Connection to 2-in Mini Spud or 4-in Standard Spud; Tri-Clamp
Table 3. I/A Series Pressure Transmitters and Applicable Pressure Seals
TransmitterModel (a)
Used with Pressure Seal Model: (b)
FLT FAD TAD ISD SCT SST FPS FES FAR TAR ISR SCR SSR
IAP10 – – –
IGP10 – – –
IAP20 – – – – – –
IGP20 – – –
IDP10 – – –
PSS 2A-1Z11 APage 5
PSFLT SERIES - FLANGED, DIRECT CONNECT (FLANGED LEVEL) PRESSURE SEALSWITH FLUSH OR EXTENDED DIAPHRAGM
The PSFLT Series Seals, with flush or extended diaphragm, are direct connect flange mounted seals used with the IDP10 or IGP20 Series DP or GP Transmitters for determination of liquid level, interface level, or density in open, pressurized, or evacuated vessels. This Transmitter-Seal System provides a reliable, precise measurement. For transmitter specifications, see applicable transmitter PSS in Table 4.
Process Pressure-Temperature Limits - ANSI and BS/DIN Flanges
(a) Do not exceed the pressure-temperature limits of the various ANSI and BS/DIN flanges and materials listed in this table.
(b) Maximum temperature allowed is 204°C (400°F) for transmitter with PSFLT seals.
Temperature Limits - PSFLT with Fill Fluids
(a) Requires silicone fill in transmitter’s sensor.
Connection to TransmitterFlanged assembly bolted to high pressure side of transmitter and sealed with a Teflon gasket. A metallic, self-energizing O-ring is available for high vacuum service.
Process-Wetted MaterialsFLUSH DIAPHRAGM
316L ss, Hastelloy C276, or TantalumEXTENDED DIAPHRAGM
316L ss or Hastelloy C276
ANSI Carbon Steel and 316 ss Flanges (a)
Process Temperature
Pressure Rating in psig - Carbon Steel Pressure Rating in psig - 316 ss
Class 150 Class 300 Class 600 Class 150 Class 300 Class 600-20 to 100°F 285 740 1480 275 720 1480
200°F 260 675 1350 240 620 1350300°F 230 655 1315 215 560 1315
400°F (b) 200 635 1270 195 515 1270BS/DIN Carbon Steel and 316 ss Flanges (a)
Process Temperature
Pressure Rating in bar gauge - Carbon Steel Pressure Rating in bar gauge - 316 ss
PN 10/40 PN 10/16 PN 25/40 PN 10/40 PN 10/16 PN 25/40-10 to +120°C 40 16 40 40 16 40
150°C 37.5 14.5 37.5 33.5 14 33.5200°C 35 13 35 32 12.5 32
204°C (b) 34.8 10.8 31.8 29.8 10.3 29.8
PSFLT WITH FLUSH DIAPHRAGM SEALSHOWN WITH IDP10 TRANSMITTER
PSFLT WITH EXTENDED DIAPHRAGM SEALSHOWN WITH IDP10 TRANSMITTER
Fill Fluid Temperature LimitsDC200, 10 cSt Silicone (a)
-40 and +204°C (-40 and +400°F)
FC77, Fluorinert -59 and +82°C (-75 and +180°F)DC200, 3 cSt Silicone (a)
-40 and +149°C (-40 and +300°F)
DC704, Silicone(a) 0 and 204°C (32 and 400°F)Neobee M20 (a) -18 and +204°C (0 and 400°F)
PSS 2A-1Z11 APage 6
PSFLT SERIES - FLANGED, DIRECT CONNECT (FLANGED LEVEL) PRESSURE SEALSWITH FLUSH OR EXTENDED DIAPHRAGM (Cont.)
Ambient Temperature Effect - Transmitter with PSFLT Seal (see tables below)
Total Effect for a 28°C (50°F) Change within Normal Operating Conditions
Values of “X” for Ambient Temperature Effect Specifications
Dimensions - NominalSee figure below and DP 020-342.
Notes1. Gasket surface has serrated finish, except for tantalum seals.
2. Extended diaphragm is suitable for up to schedule 80 unlined pipe nozzle.
3. 50 mm (2 in), 100 mm (4 in), or 15 mm (6 in) extension, as specified.
4. With IDP10 transmitters, a remote capillary connected seal may be added to the low pressure side.
Transmitter Span Limit
Code (a)
Total Ambient Temperature Effect for Transmitters with:
Electronics Versions“-D,” “-T”, “-F”, and “-V” (b)
Electronics Version“-A” only (b)
B and C ±(0.03% URL + 0.060% Span + “X”) ±(0.03% URL + 0.20% Span + “X”)D only ±(0.05% URL + 0.045% Span + “X”) ±(0.05% URL + 0.18% Span + “X”)E only ±(0.08% URL + 0.025% Span + “X”) ±(0.08% URL + 0.15% Span + “X”)
(a) Pressure seals are not applicable to transmitter Span Limit Code A.(b) URL, Span, and “X” must be in identical units. See table below for Values of “X”.
Flange Size
Value of “X” for Transmitter with a PSFLT Seal (a)
with a Flush Diaphragm with an Extended Diaphragm
mm in mmH2O inH2O mmH2O inH2O50 2 38 1.5 125 580 3 13 0.5 50 1.9100 4 Not Applicable Not Applicable 13 0.5
(a) Values listed are with seals filled with silicone DC200 or Fluorinert fill fluids.
FLUSHDIAPHRAGM
SURFACE
FIE
LDT
ER
MIN
ALS
L-H
LOW PRESSURECONNECTION(IDP10 ONLY)
GASKET SURFACE
EXTENDEDDIAPHRAGM
SURFACE
1787.0
A
MAX.
1244.9
1606.3
B
Dimensions “A” and “B”
(a) Flange dimensions are per ANSI and BS/DIN standards.
(b) Dimension “A” is optionally available with ANSI Class 150, 2- and 3-inch flanges as follows:
2-in Flange: 1.861 in (maximum)3-in Flange: 2.792 in (maximum)
SealType
FlangeSize(a)
Dim. “A”Extended
(b)Dim. “B”
Flush
Flush orExtended
502
48.31.90
582.3
Flush or Extended
803
72.42.85
893.5
Extended Only
1004
943.7
N/A
PSS 2A-1Z11 APage 7
PSFLT SERIES - FLANGED, DIRECT CONNECT (FLANGED LEVEL) PRESSURE SEALSWITH FLUSH OR EXTENDED DIAPHRAGM (Cont.)
Approximate Transmitter and Seal Mass with ANSI Flanges
NOTE: In table above, N/A means Not Applicable. Also add approximately 2 lb to values listed if a stainless steel housing is used.
Approximate Transmitter and Seal Mass with BS/DIN Flanges
NOTE: In table above, N/A means Not Applicable. Also add approximately 1 kg to values listed if a stainless steel housing is used.
ANSI Flange Rating
Flange Size and Extension Length - Approximate Mass in Pounds
2-in Flange Size 3-in Flange Size 4-in Flange Size
Flush 2-in 4-in 6-in Flush 2-in 4-in 6-in Flush 2-in 4-in 6-inClass 150 17 19 20 22 24 28 31 35 N/A 36 42 49Class 300 19 21 22 24 30 33 36 40 N/A 48 54 61Class 600 21 23 24 26 33 37 40 44 N/A 60 66 72
DIN Flange Rating
Flange Size and Extension Length - Approximate Mass in Kilograms
50 mm Flange Size 80 mm Flange Size 100 mm Flange Size
Flush50
mm100mm
150mm Flush
50mm
100mm
150mm Flush
50mm
100mm
150 mm
PN 10/40 9 9 10 11 12 13 15 16 N/A N/A N/A N/APN 10/16 N/A N/A N/A N/A N/A N/A N/A N/A N/A 14 17 20PN 25/40 N/A N/A N/A N/A N/A N/A N/A N/A N/A 17 20 23
Model Code - PSFLT Pressure SealsDescription ModelFlanged, Direct Connect (Flanged Level) Pressure Seal - with Flush or Extended Diaphragm;
used with IDP10 and IGP20 Transmitters onlyPSFLT
Seal Orientation Seal is for High Side of IDP10 and IGP20 –B
Structure Code (Flange Size, Seal Wetted Material, and Extension Length)Flange Size Seal Wetted Material Extension Length2 in (50 mm) 316L ss Flush 2S02 in (50 mm) Hastelloy C276 Flush 2C02 in (50 mm) Tantalum Flush 2T0
3 in (80 mm) 316L ss Flush 3S03 in (80 mm) Hastelloy C276 Flush 3C03 in (80 mm) Tantalum Flush 3T0
2 in (50 mm) 316L ss 2 in (50 mm) 2S22 in (50 mm) Hastelloy C276 2 in (50 mm) 2C22 in (50 mm) 316L ss 4 in (100 mm) 2S42 in (50 mm) Hastelloy C276 4 in (100 mm) 2C42 in (50 mm) 316L ss 6 in (150 mm) 2S62 in (50 mm) Hastelloy C276 6 in (150 mm) 2C6
3 in (80 mm) 316L ss 2 in (50 mm) 3S23 in (80 mm) Hastelloy C276 2 in (50 mm) 3C23 in (80 mm) 316L ss 4 in (100 mm) 3S43 in (80 mm) Hastelloy C276 4 in (100 mm) 3C43 in (80 mm) 316L ss 6 in (150 mm) 3S63 in (80 mm) Hastelloy C276 6 in (150 mm) 3C6
Model Code continued on next page
PSS 2A-1Z11 APage 8
PSFLT SERIES - FLANGED, DIRECT CONNECT (FLANGED LEVEL) PRESSURE SEALSWITH FLUSH OR EXTENDED DIAPHRAGM (Cont.)
Model Code - PSFLT Pressure Seals (Continued)
(a) Requires silicone fill in transmitter’s sensor.
ORDERING INSTRUCTIONS
Structure Code (Flange Size, Seal Wetted Material, and Extension Length) (Cont.)Flange Size Seal Material Extension Length4 in (100 mm) 316L ss 2 in (50 mm) 4S24 in (100 mm) Hastelloy C276 2 in (50 mm) 4C24 in (100 mm) 316L ss 4 in (100 mm) 4S44 in (100 mm) Hastelloy C276 4 in (100 mm) 4C44 in (100 mm) 316L ss 6 in (150 mm) 4S64 in (100 mm) Hastelloy C276 6 in (150 mm) 4C6
Flange Rating and MaterialANSI Class 150, Carbon Steel 1ANSI Class 300, Carbon Steel 2ANSI Class 600, Carbon Steel 3
BS and DIN PN 10/40, Carbon Steel ABS and DIN PN 10/16, Carbon Steel CBS and DIN PN 25/40, Carbon Steel D
ANSI Class 150, 316 ss EANSI Class 300, 316 ss FANSI Class 600, 316 ss G
BS and DIN PN 10/40, 316 ss HBS and DIN PN 10/16, 316 ss RBS and DIN PN 25/40, 316 ss T
Instrument ConnectionBolted, with Metal Self-Energizing O-ring 5
Fill Fluid - Pressure SealFill Temperature Limits
Fluid °C °FDC200, 10 cSt Silicone (a) -40 and +204 -40 and +400 1FC77, Fluorinert -59 and +82 -75 and +180 2DC200, 3 cSt Silicone (a) -40 and +149 -40 and +300 3DC704, Silicone (a) 0 and 204 32 and 400 4 Neobee M20 (a) -18 and +204 0 and 400 5
Optional SelectionsExtended Diaphragm Diameter Reduced to: Diameter Used with Structure and Flange Rating/Material Codes1.861 in (maximum) 2S21, 2S2E, 2S41, 2S4E, 2S61, 2S6E –D22.792 in (maximum) 3S21, 3S2E, 3S41, 3S4E, 3S61, 3S6E –D3
1. Transmitter Model Number from applicable Transmitter PSSe.g., IDP10–DF1C01F–M1L1C1W
Flanged Level, Silicone Fill, HI Side
2. Pressure Seal Model Number from this PSSe.g., PSFLT–B2S0153
Silicone Fill
HI Side Seal
PSS 2A-1Z11 APage 9
PSFPS AND PSFES SERIES - FLANGED CONNECTION, REMOTE MOUNT PRESSURE SEALSWITH FLUSH OR EXTENDED DIAPHRAGM
The PSFPS and PSFES with remote mount, flush or extended diaphragm seals are used with the IDP10, IGP20, IAP20, IGP10, and IAP10 Series DP, GP, and AP Transmitters. The transmitter can be mounted in a remote location with interconnecting capillary lengths up to 9 m (30 ft). This Transmitter-Seal System provides a reliable, precise measurement. For transmitter specifications, see applicable transmitter PSS in Table 4.
Process Pressure-Temperature Limits - ANSI and BS/DIN Flanges
(a) Do not exceed the pressure-temperature limits of the various ANSI and BS/DIN flanges and materials listed in this table.
(b) Maximum temperature allowed is 304°C (580°F) when using DC704 Silicone fill. See table below for temperature limits of other fill fluids.
Temperature Limits - Fill Fluids Connection to TransmitterCapillaries are provided in lengths from 1.5 to 9 m (5 to 30 ft) with 316 ss flexible armor. The armor is provided with or without a protective coat.
Process-Wetted MaterialsFLUSH DIAPHRAGM SEAL
316L ss, Hastelloy C276, or TantalumEXTENDED DIAPHRAGM SEAL
316L ss or Hastelloy C276
ANSI Carbon Steel and 316 ss Flanges (a)
Process Temperature
Pressure Rating in psig - Carbon Steel Pressure Rating in psig - 316 ss
Class 150 Class 300 Class 600 Class 150 Class 300 Class 600-20 to 100°F 285 740 1480 275 720 1480
200°F 260 675 1350 240 620 1350300°F 230 655 1315 215 560 1315400°F 200 635 1270 195 515 1270500°F 170 600 1200 170 480 1200
580°F (b) 146 560 1120 146 456 1120BS/DIN Carbon Steel and 316 ss Flanges (a)
Process Temperature
Pressure Rating in bar gauge - Carbon Steel Pressure Rating in bar gauge - 316 ss
PN 10/40 PN 10/16 PN 25/40 PN 10/40 PN 10/16 PN 25/40-10 to +120°C 40 16 40 40 16 40
150°C 37.5 14.5 37.5 33.5 14 33.5200°C 35 13 35 32 12.5 32250°C 32 11 32 30 10.5 30
304°C(b) 30 9 30 28 8.5 28
PSFPS WITH FLUSH DIAPHRAGM SEALSSHOWN WITH IDP10 TRANSMITTER
PSFES WITH EXTENDED DIAPHRAGM SEALSSHOWN WITH IDP10 TRANSMITTER
Fill Fluid Temperature LimitsDC200, 10 cSt Silicone
-40 and +232°C (-40 and +450°F)
FC77, Fluorinert -59 and +82°C (-75 and +180°F)DC200, 3 cSt Silicone
-40 and +149°C (-40 and +300°F)
DC704, Silicone 0 and 304°C (32 and 580°F)Neobee M20 -18 and +204°C (0 and 400°F)
PSS 2A-1Z11 APage 10
PSFPS AND PSFES SERIES - FLANGED CONNECTION, REMOTE MOUNT PRESSURE SEALSWITH FLUSH OR EXTENDED DIAPHRAGM (Cont.)
Seal OrientationOne or two seals, depending on the transmitter used. See Model Code further in document.
Ambient Temperature Effect and Response TimeSee performance data section at end of this document.
Approximate Transmitter Mass with PSFPS or PSFES Remote Seals with ANSI Flanges - Dual Seals each with a 5-foot Capillary
NOTE: In table above, N/A means Not Applicable. Also, add approximately 2 lb to values listed if a stainless steel housing is used.
Approximate Transmitter Mass with PSFPS or PSFES Seal with BS/DIN Flanges -Dual Seals each with a 1.5-meter Capillary
NOTE: In table above, N/A means Not Applicable. Also, add approximately 1 kg to values listed if a stainless steel housing is used.
NOTEThe Approximate Mass values listed in the tables above are with an IDP10 transmitter having an aluminum housing and process connectors. The mass for this transmitter (without capillaries or seals) is 4.2 kg (9.2 lb). Therefore, most of the mass is due to the capillary and flange configurations selected, and not by the transmitter itself.
ANSI Flange Rating
Flange Size and Extension Length - Approximate Mass in Pounds
2-in Flange Size 3-in Flange Size 4-in Flange Size
Flush 2 in 4 in 6 in Flush 2 in 4 in 6 in Flush 2 in 4 in 6 inClass 150 39 40 41 43 55 58 61 65 N/A 90 96 102Class 300 43 44 46 47 67 70 74 77 N/A 112 118 124Class 600 47 49 50 52 76 79 82 86 N/A 143 149 155
DIN Flange Rating
Flange Size and Extension Length - Approximate Mass in Kilograms
50 mm Flange Size 80 mm Flange Size 100 mm Flange Size
Flush50
mm100mm
150mm Flush
50mm
100mm
150mm Flush
50mm
100mm
150mm
PN 10/40 18 19 20 21 26 28 29 31 N/A N/A N/A N/APN 10/16 N/A N/A N/A N/A N/A N/A N/A N/A N/A 32 35 38PN 25/40 N/A N/A N/A N/A N/A N/A N/A N/A N/A 41 44 46
PSS 2A-1Z11 APage 11
PSFPS AND PSFES SERIES - FLANGED CONNECTION, REMOTE MOUNT PRESSURE SEALSWITH FLUSH OR EXTENDED DIAPHRAGM (Cont.)
Dimensions - NominalSee figure below and DP 020-343.
Notes1. Flange dimensions are per ANSI or BS/DIN standards.
2. See applicable transmitter dimensional print for transmitter dimensions.
3. Gasket surface has serrated finish, except for tantalum seals.
4. Extended diaphragm is suitable for up to schedule 80 unlined pipe nozzle.
5. 50 mm (2 in), 100 mm (4 in), or 15 mm (6 in) extension, as specified.
251.0
1244.9
130.5
A
SERRATEDGASKETSURFACE,NOTE 3
PSFPS WITHFLUSH SEAL SERRATED
GASKET SURFACE
B
FIE
LDT
ER
MIN
ALS
L-H
NOTES 4 AND 5
IDP10 TRANSMITTERSHOWN
PSFES WITHEXTENDEDSEAL
NOTE 1
Dimensions “A” and “B”
Seal TypeFlange
SizeDim. “A”
FlushDim. “B”Extended
Flush orExtended
502
993.9
47.31.90
Flush or Extended
803
1325.2
72.42.85
Extended Only
1004
N/A943.7
PSS 2A-1Z11 APage 12
PSFPS AND PSFES SERIES - FLANGED CONNECTION, REMOTE MOUNT PRESSURE SEALSWITH FLUSH OR EXTENDED DIAPHRAGM (Cont.)
Model Code continued on next page
Model Code - PSFPS and PSFES Pressure SealsDescription ModelFlanged, Remote Mount, Flush Diaphragm Pressure Seals;
for use with IDP10, IGP20, IAP20, IGP10 or IAP10 TransmittersPSFPS
Flanged, Remote Mount, Extended Diaphragm Pressure Seals;for use with IDP10, IGP20, IAP20, IGP10 or IAP10 Pressure Transmitters
PSFES
Seal Orientation Two Seal System, Balanced, Identical Model Numbered Seal on both Sides, IDP10 only –A (a)One Seal System, High Side, IDP10, IGP20, or IAP20 –BOne Seal System, Low Side, IDP10 only –COne Seal System, IGP10 or IAP10 only –D
Structure Code - Flange Size, Seal Wetted Material, and Extension LengthFlange Size Seal Wetted Extension Length50 mm (2 in) 316L ss Flush (with PSFPS Seals only) 2S050 mm (2 in) Hastelloy C276 Flush (with PSFPS Seals only) 2C050 mm (2 in) Tantalum Flush (with PSFPS Seals only) 2T080 mm (3 in) 316L ss Flush (with PSFPS Seals only) 3S080 mm (3 in) Hastelloy C276 Flush (with PSFPS Seals only) 3C080 mm (3 in) Tantalum Flush (with PSFPS Seals only) 3T0
50 mm (2 in) 316L ss 50 mm (2 in) - (with PSFES Seals only) 2S250 mm (2 in) Hastelloy C276 50 mm (2 in) - (with PSFES Seals only) 2C250 mm (2 in) 316L ss 100 mm (4 in) - (with PSFES Seals only) 2S450 mm (2 in) Hastelloy C276 100 mm (4 in) - (with PSFES Seals only) 2C450 mm (2 in) 316L ss 150 mm (6 in) - (with PSFES Seals only) 2S650 mm (2 in) Hastelloy C276 150 mm (6 in) - (with PSFES Seals only) 2C6
80 mm (3 in) 316L ss 50 mm (2 in) - (with PSFES Seals only) 3S280 mm (3 in) Hastelloy C276 50 mm (2 in) - (with PSFES Seals only) 3C280 mm (3 in) 316L ss 100 mm (4 in) - (with PSFES Seals only) 3S480 mm (3 in) Hastelloy C276 100 mm (4 in) - (with PSFES Seals only) 3C480 mm (3 in) 316L ss 150 mm (6 in) - (with PSFES Seals only) 3S680 mm (3 in) Hastelloy C276 150 mm (6 in) - (with PSFES Seals only) 3C6
100 mm (4 in) 316L ss 50 mm (2 in) - (with PSFES Seals only) 4S2100 mm (4 in) Hastelloy C276 50 mm (2 in) - (with PSFES Seals only) 4C2100 mm (4 in) 316L ss 100 mm (4 in) - (with PSFES Seals only) 4S4100 mm (4 in) Hastelloy C276 100 mm (4 in) - (with PSFES Seals only) 4C4100 mm (4 in) 316L ss 150 mm (6 in) - (with PSFES Seals only) 4S6100 mm (4 in) Hastelloy C276 150 mm (6 in) - (with PSFES Seals only) 4C6
Flange Rating and MaterialANSI Class 150, Carbon Steel 1ANSI Class 300, Carbon Steel 2ANSI Class 600, Carbon Steel 3
BS and DIN PN 10/40 (for 50 and 80 mm only), Carbon Steel ABS and DIN PN 10/16 (for 100 mm only), Carbon Steel (PSFES Seals Only) CBS and DIN PN 25/40 (for 100 mm only), Carbon Steel (PSFES Seals Only) D
ANSI Class 150, 316 ss EANSI Class 300, 316 ss FANSI Class 600, 316 ss G
PSS 2A-1Z11 APage 13
PSFPS AND PSFES SERIES - FLANGED CONNECTION, REMOTE MOUNT PRESSURE SEALSWITH FLUSH OR EXTENDED DIAPHRAGM (Cont.)
(a) Specify quantity of 2 identical seals when Seal Orientation Code “A” is specified.
(b) Requires silicone fill in transmitter’s sensor.
ORDERING INSTRUCTIONS(for Transmitter with PSFPS or PSFES Seals)
Model Code - PSFPS and PSFES Pressure Seals (Cont.)Flange Rating and Material (Cont.) ModelBS and DIN PN 10/40 (for 50 and 80 mm only), 316 ss HBS and DIN PN 10/16 (for 100 mm only), 316 ss (PSFES Seals Only) RBS and DIN PN 25/40 (for 100 mm only), 316 ss (PSFES Seals Only) TFlange Provided by User (PSFPS Seals Only) Y
Instrument ConnectionsLow Volume; capillary welded at both instrument and seal 3
Fill Fluid - Pressure Seal and CapillaryFill Temperature Limits
Fluid °C °FDC200, 10 cSt Silicone (b) -40 and +232 -40 and +450 1FC77, Fluorinert -59 and +82 -75 and +180 (Not available with IAP10 or IAP20) 2DC200, 3 cSt Silicone (b) -40 and +149 -40 and +300 3DC704, Silicone (b) 0 and 304 32 and 580 4 Neobee M20 (b) -18 and +204 0 and 400 5
Capillary Internal Diameter0.027 inches; Not Available with DC704 Silicone, Fill Fluid Code 4 30.040 inches 40.062 inches; Not Available with IAP10 or IGP10 Transmitters 6
Capillary Length and Type1.5 m (5 ft) 316 ss Flexible Armor A3.0 m (10 ft) 316 ss Flexible Armor B4.5 m (15 ft) 316 ss Flexible Armor C6.0 m (20 ft) 316 ss Flexible Armor D7.5 m (25 ft) 316 ss Flexible Armor E9.0 m (30 ft) 316 ss Flexible Armor F
1.5 m (5 ft) 316 ss Flexible Armor, Protective Coat G3.0 m (10 ft) 316 ss Flexible Armor, Protective Coat H4.5 m (15 ft) 316 ss Flexible Armor, Protective Coat J6.0 m (20 ft) 316 ss Flexible Armor, Protective Coat K7.5 m (25 ft) 316 ss Flexible Armor, Protective Coat L9.0 m (30 ft) 316 ss Flexible Armor, Protective Coat M
Optional SelectionsExtended Diaphragm Diameter Reduced to: Diameter Used with Structure and Flange Rating/Material Codes1.861 in (maximum) 2S21, 2S2E, 2S41, 2S4E, 2S61, 2S6E –D22.792 in (maximum) 3S21, 3S2E, 3S41, 3S4E, 3S61, 3S6E –D3
1. Applicable Transmitter Model Number (See Transmitter PSS)
Remote Seal, Silicone Fill, HI and LO Sides
2. Pressure Seal Model Number from this PSS
Silicone Fill
e.g., IDP10–DS1C01F–X1Z3K1
e.g., PSFPS–A2S01334H (Quantity of 2 Required)
Two Seal System
PSS 2A-1Z11 APage 14
PSFAR AND PSFAD SERIES, FLANGED CONNECTION, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGMS
The PSFAR, with remote mount, flanged recessed diaphragm seals, is used with the IDP10, IGP20, IAP20, IGP10, and IAP10 Series DP, GP, and AP Transmitters. The PSFAD, with direct connect, recessed diaphragm seals, is used with the IGP10 and IAP10 Series GP and AP Transmitters. These Transmitter-Seal Systems provide precise, reliable measurements. For transmitter specifications, see applicable transmitter PSS in Table 4.
Pressure-Temperature Ratings (a)(b)
(a) Maximum temperature limit with PSFAD is 400°F.(b) Maximum temperature limit with PSFAR is 580°F.
Fill Fluid-Pressure Seal and Capillary
(a) When used with a direct connect PSFAD seal, the temperature limit is reduced to 204°C (400°F).
NOTES1. When ptfe and PVC lower housings are
used, the maximum working pressure allowed is 150 psig (1035 kPa).
2. Do not exceed the flange pressure-temperature limits listed in the adjacent tables.
3. Carbon steel flanges are used with carbon steel upper housings; 316 ss flanges are used with 316L ss, Monel, and titanium upper housings.
PSFAR FLANGED, REMOTE MOUNTSHOWN WITH IDP10 TRANSMITTER
PSFAD FLANGED, DIRECT CONNECTSHOWN WITH IGP10 TRANSMITTER
ANSI Carbon Steel Flanges
Process Temp.
Pressure Rating in psig
Cl. 150 Cl. 300 Cl. 600 Cl. 1500-20°F 285 740 1480 3705100°F 285 740 1480 3705200°F 260 675 1350 3375300°F 230 655 1315 3280
400°F(a) 200 635 1270 3170500°F 170 600 1200 2995
580°F(b) 146 560 1120 2785ANSI 316 ss Flanges
Process Temp.
Pressure Rating in psig
Cl. 150 Cl. 300 Cl. 600 Cl. 1500-20°F 275 720 1440 3600100°F 275 720 1440 3600200°F 240 620 1240 3095300°F 215 560 1120 2795
400°F(a) 195 515 1030 2570500°F 170 480 955 2390
580°F(b) 146 456 915 2280
Fill Fluid Temperature Limits
DC200, 10 cSt Silicone
-40 and +232°C (-40 and +450°F)Note (a)
FC77, Fluorinert -59 and +82°C (-75 and +180°F)DC200, 3 cSt Silicone
-40 and +149°C (-40 and +300°F)
DC704, Silicone 0 and 304°C (32 and 580°F) (a)Neobee M20 -18 and +204°C (0 and 400°F)
PSS 2A-1Z11 APage 15
PSFAR AND PSFAD SERIES, FLANGED CONNECTION, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
Process Wetted MaterialsLOWER HOUSING
Carbon steel, 316 ss, Hastelloy C276, Tantalum, Titanium Gr. 4, Inconel 600, Monel 400, Nickel 200, glass-filled Teflon, or PVC.
DIAPHRAGM316L ss, Hastelloy C276, Tantalum, Titanium Gr. 2, Inconel 600, Monel 400, or Nickel 200.
GASKETOrganic fiber with Nitrile, Buna-N, Grafoil®, silver-plated Hastelloy C, Viton®, silver plated 316 ss, or Teflon.
Seal OrientationSeal can be on HI or LO side, or both sides depending on transmitter used. See Model Code.
Connection to ProcessDepends on process connector. Seal is attached to process flange using bolts or studs located on the lower housing. See Dimensions section below.
Connection to TransmitterREMOTE MOUNT (PSFAR ONLY)
Low volume; welded to capillary connection at the transmitter (1/4 NPT thread at seal for capillary)
DIRECT MOUNT (PSFAD ONLY)A 1/2 NPT internal thread on upper housing directly connects to an IGP10 or IAP10 transmitter.
Ambient Temperature Effect and Response TimeApplicable to remote, capillary connected seals only. See PERFORMANCE DATA at end of this document.
Dimensions - NominalSee figures below and DP 020-345 and DP 020-346.
1/4 NPT WITHPSFAR; 1/2 NPTWITH PSFAD
USER SUPPLIEDFLANGE BOLTSCONNECT TO PROCESS FLANGE
SECTIONX-X
X X
LOWERHOUSING SECTION
Y-Y
Y
UPPERHOUSINGBOLTED TOLOWERHOUSING
STUDS ONLOWERHOUSINGCONNECT TOPROCESSFLANGE
1/4 NPT WITHPSFAR; 1/2 NPTWITH PSFAD
A
BB
A
BOLT MOUNTING CONSTRUCTION STUD MOUNTING CONSTRUCTION
PSS 2A-1Z11 APage 16
PSFAR AND PSFAD SERIES, FLANGED CONNECTION, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
Model Code - PSFAR and PSFAD Pressure Seals
Description ModelFlanged, Remote Mount, Recessed Diaphragm Seals;for use with IDP10, IGP20, IAP20, IGP10 and IAP10 Transmitters.
PSFAR
Flanged, Direct Connect, Recessed Diaphragm Seals;for use with IGP10 and IAP10 Transmitters only.
PSFAD
Seal Orientation - Specify for PSFAR Seals Only; for PSFAD Seals, go to Diaphragm SizeTwo Seal System, Balanced - Same Seal on both Sides, IDP10 only –A (a)One Seal System, High Side, IDP10, IGP20, or IAP20 only –BOne Seal System, Low Side, IDP10 only –COne Seal System, IGP10 or IAP10 only –D
Diaphragm Size 2.4 in (Typical for IGP10 and IAP10) 23.0 in (Typical for IDP10 and IGP20) 34.0 in (Recommended for minimized temperature effect) - used with PSFAR only 4
Process Connector (cs flange with cs upper housing; 316 ss flange with other upper housings)1/2 in Raised Face Flange A3/4 in Raised Face Flange B1 in Raised Face Flange 11 1/2 in Raised Face Flange C2 in Raised Face Flange 23 in Raised Face Flange 3
Flange RatingANSI Class 150 1ANSI Class 300 2ANSI Class 600 3ANSI Class 1500 - Not available with Diaphragm Size Code 3 (3.0 in); This selection requires selection of Gasket Codes 3 or C (metal gaskets)
4
2.4 in DiaphragmBolt Mounting Construction (a)
PSFAR AND PSFAD
ANSI Flange A B1 in, Cl. 150 4.25 2.191 in, Cl. 300 5.50 2.062 in, Cl. 150 6.00 2.192 in, Cl. 300 6.50 2.383 in, Cl. 150 7.50 2.633 in, Cl. 300 8.25 3.31
3.0 in DiaphragmStud Mounting Construction (a)
PSFAR AND PSFAD
ANSI Flange A B1/2 in, Cl. 150 4.25 2.051/2 in, Cl. 300 4.25 2.053/4 in, Cl. 150 4.25 2.053/4 in, Cl. 300 4.62 2.051 in, Cl. 150 4.25 2.051 in, Cl. 300 5.88 2.36
1 1/2 in, Cl. 150 5.00 2.051 1/2 in, Cl. 300 6.12 2.76
4.0 in DiaphragmStud Mounting Construction (a)
PSFAR Only
ANSI Flange A B1/2 in, Cl. 150 5.50 2.251/2 in, Cl. 300 5.50 2.253/4 in, Cl. 150 5.50 2.253/4 in, Cl. 300 5.50 2.251 in, Cl. 150 5.50 2.251 in, Cl. 300 5.50 2.25
2.4 in DiaphragmStud Mounting Construction (a)
PSFAR AND PSFAD
ANSI Flange A B1/2 in, Cl. 150 4.00 1.941/2 in, Cl. 300 4.00 1.983/4 in, Cl. 150 4.00 1.943/4 in, Cl. 300 4.25 1.98
3.0 in DiaphragmBolt Mounting Construction (a)
PSFAR AND PSFAD
ANSI Flange A B2 in, Cl. 150 6.00 2.192 in, Cl. 300 6.50 2.193 in, Cl. 150 7.50 2.253 in, Cl. 300 8.25 2.25
4.0 in DiaphragmBolt Mounting Construction (a)
PSFAR Only
ANSI Flange A B2 in, Cl. 150 6.00 2.632 in, Cl. 300 6.50 2.763 in, Cl. 150 7.50 2.323 in, Cl. 300 8.25 2.32
(a) Dimensions in inches. For dimensions when using ANSI Class 600 or 1500 flanges, contact Invensys Foxboro.
PSS 2A-1Z11 APage 17
PSFAR AND PSFAD SERIES, FLANGED CONNECTION, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
Model Code continued on next page
Model Code - PSFAR and PSFAD Pressure Seals (Continued)Description (Continued) ModelLower Housing Material (Process Wetted) 316 ss SCarbon Steel KHastelloy C276 CTantalum Plate; required selection of Tantalum Diaphragm Material Code T TTitanium Grade 4 EGlass Filled Teflon - requires selection of Gasket Code T (Teflon) (b) GInconel 600 LMonel 400 MNickel 200 NPolyvinyl Chloride (PVC) - requires selection of Gasket Code T (Teflon) (b) P
Diaphragm Material316L ss SHastelloy C276 CTantalum; standard with Lower Housing Code T (Tantalum Plate) TTitanium Grade 2 - requires selection of Upper Housing Material Code T (Titanium) EInconel 600 LMonel 400 - requires selection of Upper Housing Code M (Monel) MNickel 200 N
Upper Housing Material (Not Process Wetted) (b) Carbon Steel K316L ss SMonel 400 - requires Diaphragm Code M (Monel 400) MTitanium Grade 4 - requires Diaphragm Code E (Titanium) E
Instrument Connection PSFAR Only - Capillary welded to transmitter; 1/4 NPT at seal 1PSFAD Only - 1/2 NPT 2
Gasket Organic Fiber with Nitrile binder; Standard with Class 150 and Class 300 Flanges S316 ss, Silver Plated; not available with ANSI Class 150 and 300 Flanges 3Teflon; Standard with Nonmetallic Lower Housings TBuna N BViton VGrafoil GHastelloy C, Silver Plated; not available with ANSI Class 150 and 300 Flanges C
Flushing Connector None A1/4 NPT BDual 1/4 NPT C
Bolting - Used with Stud Mounting Configuration (see Dimensions Section)None - See Note (c) 0Carbon Steel (Standard Construction) C300 Series ss (for ANSI Class 300 and Lower) S
PSS 2A-1Z11 APage 18
PSFAR AND PSFAD SERIES, FLANGED CONNECTION, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
(a) When Seal Orientation Code A is specified, then indicate that two identically model numbered seals are required.
(b) The maximum working pressure with the nonmetallic ptfe and PVC lower housings is 150 psig, regardless of the higher allowable flange pressure ratings.
(c) Bolting Code 0 (None) only available with:– Code 2 Diaphragm Size with Process Connector Codes 1, C, 2, and 3 (Flanges 1 in or greater).– Code 3 Diaphragm Size with Process Connector Codes 2 and 3 (2- and 3-in Flanges only).
(d) Fluorinert FC77 fill not available with IAP10 or IAP20 Transmitters.
(e) Requires silicone fill in transmitter’s sensor.
NOTEFor flange types, ratings, materials of construction, seal gaskets, fill fluids, etc.,other than those listed in the Model Code, contact Invensys Foxboro.
ORDERING INSTRUCTIONS
Model Code - PSFAR and PSFAD Pressure Seals (Cont.)Fill Fluid - Pressure Seal and Capillary Model
Fill Temperature Limits (PSFAR) Temperature Limits (PSFADFluid °C °F °C °FDC200, 10 cSt Silicone (e) -40 and +232 -40 and +450 -40 and +204 -40 and +400 1FC77, Fluorinert (d) -59 and +82 -75 and +180 -59 and +82 -75 and +180 2DC200, 3 cSt Silicone (e) -40 and +149 -40 and +300 -40 and +149 -40 and +300 3DC704, Silicone (e) 0 and 304 32 and 580 0 and 204 32 and 400 4 Neobee M20 (e) -18 and +204 0 and 400 -18 and +204 0 and 400 5
Capillary Internal Diameter - Select for PSFAR Seals Only0.027 in; Not Available with Fluid Code 4 (DC704 Silicone) 30.040 in 40.062 in; Not Available with IAP10, IGP10 Transmitters 6
Capillary Length and Type - Select for PSFAR Seals Only1.5 m (5 ft) 316 ss Flexible Armor A3.0 m (10 ft) 316 ss Flexible Armor B4.5 m (15 ft) 316 ss Flexible Armor C6.0 m (20 ft) 316 ss Flexible Armor D7.5 m (25 ft) 316 ss Flexible Armor E9.0 m (30 ft) 316 ss Flexible Armor F
1.5 m (5 ft) 316 ss Flexible Armor, Protective Coat G3.0 m (10 ft) 316 ss Flexible Armor, Protective Coat H4.5 m (15 ft) 316 ss Flexible Armor, Protective Coat J6.0 m (20 ft) 316 ss Flexible Armor, Protective Coat K7.5 m (25 ft) 316 ss Flexible Armor, Protective Coat L9.0 m (30 ft) 316 ss Flexible Armor, Protective Coat M
1. Applicable Transmitter Model Number (See Transmitter PSS)e.g., IGP10–D22D1F–L1C1W
Silicone Fill Fluid, 316L ss Sensor and Process Connection
2. Pressure Seal Model Number from this PSSe.g., PSFAD–D232SSS2SBC1
Silicone Fill
1/2 NPT Connection for Direct
Direct Connected Gauge Pressure Transmitter
Connected Transmitter
PSS 2A-1Z11 APage 19
PSTAR AND PSTAD SERIES, THREADED CONNECTION,REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM
The PSTAR, with remote mount, threaded, recessed diaphragm seals, is used with the IDP10, IGP20, IAP20, IGP10, and IAP10 DP, GP, and AP Transmitters. The PSTAD, with direct connect, threaded seals, is used with the IGP10 and IAP10 Series GP and AP Transmitters. These transmitter-seal systems are used when a threaded connection to the process is required, along with precise reliable measurements. For Transmitter specifications, see applicable transmitter PSS in Table 4.
Pressure-Temperature Limits (a)(b)
(a) The maximum temperature allowed with PSTAD is 400°F.
(b) Maximum temperature limit with PSTAR is 580°F.
Fill Fluid-Pressure Seal and Capillary
(a) When used with a direct connect PSTAD seal, the temperature limit is reduced to 204°C (400°F).
Seal OrientationSeal can be on HI or LO side, or both sides depending on transmitter used. See Model Code.
Process Wetted MaterialsLOWER HOUSING
Carbon steel, 316 ss, Hastelloy C, Titanium Gr. 4, Inconel 600, Monel 400, or Nickel 200.
DIAPHRAGMCarbon steel, 316L ss, Hastelloy C276, Tantalum, Titanium Gr. 2, Inconel 600, Monel 400, or Nickel 200.
GASKETOrganic fiber with Nitrile, Grafoil, Buna N, Viton, or Teflon.
Connection to TransmitterREMOTE MOUNT (PSFAR ONLY)
Low volume; welded capillary connection at the transmitter (1/4 NPT thread at seal for capillary).
DIRECT CONNECT (PSTAD ONLY)A 1/2 NPT internal thread on the upper housing directly connects to an IGP10 or IAP10 transmitter.
Connection to ProcessThe seal is connected to the process with 1/4, 1/2, 3/4, 1, and 1 1/2 NPT internal threads located on the lower housing. A transmitter mounting bracket is recommended when using a direct connected transmitter with the 1/4 NPT connection.
Ambient Temperature Effect and Response TimeApplicable to remote, capillary connected seals only. See PERFORMANCE DATA further in document.
PSTAR, THREADED, REMOTE MOUNTSHOWN WITH IDP10 TRANSMITTER
PSTAD, THREADED, DIRECT CONNECTSHOWN WITH IGP10 TRANSMITTER
Process Temperature
Pressure Rating Code “C”
Pressure Rating Code “U”
-20°F 1250 psig 2500 psig100°F 1250 psig 2500 psig200°F 1075 psig 2150 psig300°F 975 psig 1950 psig
400°F (a) 900 psig 1800 psig500°F 835 psig 1670 psig
580°F (b) 803 psig 1606 psig
Fill Fluid Temperature LimitsDC200, 10 cSt Silicone
-40 and +232°C (-40 and +450°F)Note (a)
FC77, Fluorinert -59 and +82°C (-75 and +180°F)DC200, 3 cSt Silicone
-40 and +149°C (-40 and +300°F)
DC704, Silicone 0 and 304°C (32 and 580°F) (a)Neobee M20 -18 and +204°C (0 and 400°F)
PSS 2A-1Z11 APage 20
PSTAR AND PSTAD SERIES, THREADED CONNECTION, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
Dimensions - NominalSee figure below and DPs 020-347 and 020-348.
A
B B
A
1/4 NPT WITHPSTAR; 1/2 NPTWITH PSTAD
1/4 NPT WITHPSTAR
UPPERHOUSING
LOWERHOUSING
SECTIONX-X
UPPERHOUSING
LOWERHOUSING
SECTIONY-Y1/4 TO 1 1/2 NPT TO
PROCESS CONNECTION1/4 TO 1 1/2 NPT TOPROCESS CONNECTIONX
X
Y
Y
PSTAR AND PSTAD 2.4 AND 3.0 in DIAPHRAGMS PSTAR ONLY 4.0 in DIAPHRAGM
WHEN A DIRECTCONNECTED TRANS-MITTER IS USED WITHA 1/4 NPT PROCESSCONNECTION, IT ISRECOMMENDED THAT ATRANSMITTER MOUNTINGBRACKET BE USED.
NOTE
PSTAR and PSTAD Dimensions - Inches2.4 in and 3 in Diaphragm Sizes
(a) 2.4 in diaphragm size used with IGP10 and IAP10 Transmitters.
(b) 3.0 in diaphragm size used with IDP10, IGP20, and IAP20 Transmitters.
(c) 2500 psig rating is when using carbon steel bolts. See adjacent NOTE.
Diaphragm Size
Process Connection
Pressure Rating
(c)
Dimensions
A B
2.4 in (a) 1/4 NPT 2500 psig 3.50 1.562.4 in (a) 1/2 NPT 2500 psig 3.50 2.002.4 in (a) 3/4 NPT 2500 psig 3.50 2.002.4 in (a) 1 NPT 2500 psig 3.50 2.002.4 in (a) 1 1/2 NPT 2500 psig 3.50 2.003.0 in (b) 1/4 NPT 2500 psig 4.25 2.003.0 in (b) 1/2 NPT 2500 psig 4.25 2.003.0 in (b) 3/4 NPT 2500 psig 4.25 2.003.0 in (b) 1 NPT 2500 psig 4.25 2.003.0 in (b) 1 1/2 NPT 2500 psig 4.25 2.00
PSTAR Only Dimensions - Inches4.0 in Diaphragm Size
(a) Code 4 (4.0 in) diaphragm size used with PSTAR only for optimal temperature performance.
(b) The 1500 psig rating is when using carbon steel bolts. See NOTE below.
NOTEThe 2500 psig and 1500 psig ratings in the tablesare when carbon steel bolts are used. When using300 Series stainless steel bolts, the pressureratings are derated to 1250 psig and 750 psigrespectively.
Diaphragm Size
Process Connection
Pressure Rating (b)
Dimensions
A B
4.0 in (a) 1/4 NPT 1500 psig 5.50 2.124.0 in (a) 1/2 NPT 1500 psig 5.50 2.124.0 in (a) 3/4 NPT 1500 psig 5.50 2.124.0 in (a) 1 NPT 1500 psig 5.50 2.124.0 in (a) 1 1/2 NPT 1500 psig 5.50 2.12
PSS 2A-1Z11 APage 21
PSTAR AND PSTAD SERIES, THREADED CONNECTION, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
(a) When Seal Orientation Code A is specified, then indicate that two identically model numbered seals are required.(b) For reduced temperature effects at small spans when used with a PSTAD seal.(c) See Pressure-Temperature Limits Table for pressure ratings at temperature above 100°F.
Model Code - PSTAR and PSTAD Pressure SealsDescription ModelThreaded Connection, Remote Mount, Recessed Diaphragm Seals;
for use with IDP10, IGP20, IAP20, IGP10 and IAP10 Transmitters.PSTAR
Threaded Connection, Direct Connect, Recessed Diaphragm Seals;for use with IGP10 and IAP10 Transmitters only.
PSTAD
Seal Orientation - Select for PSTAR Seals OnlyTwo Seal System, Balanced - Identical Seal on both Sides, IDP10 only –A (a)One Seal System, High Side, IDP10, IGP20 or IAP20 only –BOne Seal System, Low Side, IDP10 only –COne Seal System, IGP10 or IAP10 only –D
Diaphragm Size 2.4 in (Typical for IGP10 and IAP10) 2 3.0 in (Typical for IDP10, IGP20, and IAP20) (b) 3 4.0 in (for Optimal Temperature Performance) - Used with PSTAR only 4
Process Connector1/4 in NPT, Internally Threaded 11/2 in NPT, Internally Threaded 23/4 in NPT, Internally Threaded 31 in NPT, Internally Threaded 41 1/2 in NPT, Internally Threaded 5
Pressure RatingPressure Rating at 100°F (38°C) (c) U
Lower Housing Material (Process Wetted)316 ss SCarbon Steel KHastelloy C CTitanium Grade 4 EInconel 600 LMonel 400 MNickel 200 N
Diaphragm Material316L ss S Carbon Steel KHastelloy C276 CTantalum TTitanium Grade 2 (must Specify Titanium Upper Housing - Code E that follows) EInconel 600 LMonel 400 (must Specify Monel Upper Housing - Code M that follows) MNickel 200 N
Diaphragm Size
Seal Model
Pressure Rating at 100°F (38°C) with:
Carbon Steel Bolts
Stainless Steel Bolts
2.4 in PSTAR/(PSTAD 2500 psig 1250 psig3.0 in PSTAR/PSTAD 2500 psig 1250 psig4.0 in PSTAR Only 1500 psig 750 psig
PSS 2A-1Z11 APage 22
PSTAR AND PSTAD SERIES, THREADED CONNECTION, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
(a) Requires silicone fill in transmitter’s sensor.
(b) Fluorinert fill not available with IAP10 or IAP20 transmitter.
Model Code continued on next page
Model Code - PSTAR and PSTAD Pressure Seals (Cont.)Upper Housing Material ModelCarbon Steel K316L ss SMonel 400 - Requires Selection of Diaphragm Material Code M MTitanium Grade 4 - Requires Selection of Diaphragm Material Code E E
Instrument Connection PSTAR Only - Capillary Welded to Transmitter; 1/4 NPT at Seal 1PSTAD Only - 1/2 NPT 2
Gasket Organic Fiber with Nitrile Binder; Standard with Most Metallic Lower Housings STeflon TBuna N BViton VGrafoil G
Flushing Connector None A1/4 NPT BDual 1/4 NPT (with PSTAR only) C
BoltingCarbon Steel (Typical selection for 2500 psig Pressure Rating) C300 Series ss (Derated to 1250 psig Pressure Rating) S
Fill Fluid - Pressure SealFill Temperature Limits (PSTAR) Temperature Limits (PSTAD)
Fluid °C °F °C °FDC200, 10 cSt Silicone (a) -40 and +232 -40 and +450 -40 and +204 -40 and +400 1FC77, Fluorinert (b) -59 and +82 -75 and +180 -59 and +82 -75 and +180 2DC200, 3 cSt Silicone (a) -40 and +149 -40 and +300 -40 and +149 -40 and +300 3DC704, Silicone (a) 0 and 304 32 and 580 0 and 204 32 and 400 4 Neobee M20 (a) -18 and +204 0 and 400 -18 and +204 0 and 400
Capillary Internal Diameter - Select for PSTAR Seals Only0.027 in; Not Available with Fill Fluid Code 4 (DC704 Silicone) 30.040 in 40.062 in; Not Available with IGP10 or IAP10 Transmitters 6
PSS 2A-1Z11 APage 23
PSTAR AND PSTAD SERIES, THREADED CONNECTION, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
ORDERING INSTRUCTIONS
Model Code - PSTAR and PSTAD Pressure Seals (Cont.)Capillary Length and Type - Select for PSTAR Seals Only Model1.5 m (5 ft) 316 ss Flexible Armor A3.0 m (10 ft) 316 ss Flexible Armor B4.5 m (15 ft) 316 ss Flexible Armor C6.0 m (20 ft) 316 ss Flexible Armor D7.5 m (25 ft) 316 ss Flexible Armor E9.0 m (30 ft) 316 ss Flexible Armor F
1.5 m (5 ft) 316 ss Flexible Armor, Protective Coat G3.0 m (10 ft) 316 ss Flexible Armor, Protective Coat H4.5 m (15 ft) 316 ss Flexible Armor, Protective Coat J6.0 m (20 ft) 316 ss Flexible Armor, Protective Coat K7.5 m (25 ft) 316 ss Flexible Armor, Protective Coat L9.0 m (30 ft) 316 ss Flexible Armor, Protective Coat M
1. Applicable Transmitter Model Number (See Transmitter PSS)e.g., IGP20–DS3C01F–M2C2WT
Silicone Fill, Remote Seal on HI Side
2. Pressure Seal Model Number from this PSSe.g., PSTAR–B32CSSSSBC34K
Silicone FillHI Side Seal, IGP20 Transmitter
Bracket Mounted Gauge Pressure Transmitter
PSS 2A-1Z11 APage 24
PSISR AND PSISD SERIES, IN-LINE SADDLE WELD, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGMS
The PSISR, with remote mount, in-line welded, recessed diaphragm seals, is used with the IDP10, IGP20, IAP20, IGP10, and IAP10 Series DP, GP, and AP Transmitters. The PSISD, with direct mount, in-line welded seals, is used with the IGP10 and IAP10 Series GP and AP Transmitters. These transmitter-seal systems are used in applications that require a continuous process flow across the diaphragm to insure that pressure sensing is not inhibited by buildup of solids. For transmitter specifications, see applicable transmitter PSS in Table 4.
Process Pressure-Temperature LimitsThe maximum working pressure is equivalent to a nominal 3- or 4-inch Schedule 40 pipe as defined by ASME/ANSI standards. Do not exceed this pressure rating, nor the temperature limits of the fill fluid selected.
Fill Fluid - Pressure Seal and Capillary
(a) When used with a direct connect PSISD seal, the temperature limit is reduced to 204°C (400°F).
Process Wetted MaterialsLOWER HOUSING
Carbon steel, 316 ss, Hastelloy C, Titanium Gr. 4, Monel 400, Nickel 200, and Inconel 600.
DIAPHRAGM316L ss, Hastelloy C276, Tantalum, Monel 400, Titanium Gr. 2, Nickel 200, and Inconel 600.
GASKETOrganic fiber with Nitrile binder, or Teflon.
Seal OrientationSeal can be on HI or LO side, or both sides depending on transmitter. See Model Code.
Connection to TransmitterREMOTE MOUNT (PSISR ONLY)
Low volume; welded capillary connection at the transmitter (1/4 NPT thread at the seal).
DIRECT MOUNT (PSISD ONLY)A 1/2 NPT internal thread on upper housing directly connects to an IAP10 or IGP10 transmitter.
Connection to ProcessThe lower housing of the seal is in-line, saddle welded to a nominal 3- or 4-inch (and larger) pipe. After welding the lower section to the pipe, the upper section (which has the diaphragm welded to it) is then bolted to the lower section.
Ambient Temperature Effect and Response TimeApplicable to remote, capillary connected seals only. See PERFORMANCE DATA section further in document.
PSISR, SADDLE WELD, REMOTE MOUNTSHOWN WITH IGP10 TRANSMITTER
PSISD, SADDLE WELD, DIRECT CONNECTSHOWN WITH IGP10 TRANSMITTER
Fill Fluid Temperature Limits
DC200, 10 cSt Silicone
-40 and +232°C (-40 and +450°F)Note (a)
FC77, Fluorinert -59 and +82°C (-75 and +180°F)DC200, 3 cSt Silicone
-40 and +149°C (-40 and +300°F)
DC704, Silicone 0 and 304°C (32 and 580°F) (a)Neobee M20 -18 and +204°C (0 and 400°F)
PSS 2A-1Z11 APage 25
PSISR AND PSISD SERIES, IN-LINE SADDLE WELD, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
Dimensions - NominalSee figures below and DPs 020-349 and 020-350.
PROCESS PIPE(REFERENCE)
UPPER HOUSING
LOWER HOUSING
IN-LINE SADDLE WELDTHE LOWER HOUSINGTO PROCESS PIPE PRIORTO ASSEMBLING UPPERHOUSING TO LOWERHOUSING.
DIAPHRAGM WELDED TO UPPER HOUSING
3-INCH (BUT LESS THAN4-INCH) PROCESS PIPE
4-INCH PROCESS PIPEAND LARGER
1/4 NPT WITH PSISR1/2 NPT WITH PSISD
89
3.5
57
2.2
52
2.03
79
3.1
52
2.03
76
3.0
66
2.6
89
3.5
PSS 2A-1Z11 APage 26
PSISR AND PSISD SERIES, IN-LINE SADDLE WELD, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
(a) When Seal Orientation Code A is specified, then indicate that two identically model numbered seals are required. See example on next page.
Model Code continued on next page
Model Code - PSISR and PSISD Pressure Seals
Description ModelIn-Line Saddle Weld Connection, Remote Mount, Recessed Diaphragm Seals;for use with IDP10, IGP20, IAP20, IGP10 and IAP10 Transmitters.
PSISR
In-Line Saddle Weld Connection, Direct Connect, Recessed Diaphragm Seals;for use with IGP10 and IAP10 Transmitters only.
PSISD
Seal Orientation - PSISR Seals Only; for PSISD Seals, go to Diaphragm Size SelectionTwo Seal System, Balanced - Identical Seal on both Sides, IDP10 only –A (a)One Seal System, High Side, IDP10, IGP20, or IAP20 only –BOne Seal System, Low Side, IDP10 only –COne Seal System, IGP10 or IAP10 only –D
Diaphragm Size 2.4 in 2
Process Connector In-Line, Saddle Weld to Nominal 3-inch Pipe 3In-Line, Saddle Weld to Nominal 4-inch Pipe 4
Pressure Rating Equivalent to a Nominal 3- or 4-inch Schedule 40 Pipe J
Lower Housing Material (Process Wetted) 316 ss SCarbon Steel KHastelloy C CTitanium Grade 4 EInconel 600 LMonel 400 MNickel 200 N
Diaphragm Material 316L ss SHastelloy C276 CTantalum TTitanium Grade 2 (must Specify Titanium Upper Housing - Code E below) EInconel 600 LMonel 400 (must Specify Monel Upper Housing - Code M below) MNickel 200 N
Upper Housing MaterialCarbon Steel K316L ss SMonel 400 (requires Monel - Code M Diaphragm) MTitanium Grade 4 (requires Titanium - Code E Diaphragm) E
PSS 2A-1Z11 APage 27
PSISR AND PSISD SERIES, IN-LINE SADDLE WELD, REMOTE MOUNT OR DIRECT CONNECT PRESSURE SEALS WITH RECESSED DIAPHRAGM (Cont.)
(a) The PSISR and PSISD use a standard eight-bolt pattern. If a custom six-bolt pattern is required, contact Invensys Foxboro.
(b) Requires silicone fill in transmitter’s sensor.
(c) Fluorinert fill not available with IAP10 or IAP20 Transmitter.
ORDERING INSTRUCTIONS
Model Code - PSISR and PSISD Pressure Seals (Cont.)
Instrument Connection ModelPSISR Only - Low Volume; capillary welded at the transmitter; 1/4 NPT at seal 1PSISD Only - 1/2 NPT 2
GasketOrganic Fiber with Nitrile binder (Standard) STeflon T
Bolting (a)Carbon Steel (Standard) C300 Series ss S
Fill Fluid - Pressure SealFill Temperature Limits (PSTAR Temperature Limits (PSTAD)
Fluid °C °F °C °FDC200, 10 cSt Silicone (b) -40 and +232 -40 and +450 -40 and +204 -40 and +400 1FC77, Fluorinert (c) -59 and +82 -75 and +180 -59 and +82 -75 and +180 2DC200, 3 cSt Silicone (b) -40 and +149 -40 and +300 -40 and +149 -40 and +300 3DC704, Silicone (b) 0 and 304 32 and 580 0 and 204 32 and 400 4 Neobee M20 (b) -18 and +204 0 and 400 -18 and +204 0 and 400
Capillary Internal Diameter - Select for PSISR Seals Only0.027 in; Not Available with Fluid Code 4 (DC704) 30.040 in 40.062 in; Not Available with IGP10, IAP10 Transmitters 6
Capillary Length and Type - Select for PSISR Seals Only1.5 m (5 ft) 316 ss Flexible Armor A3.0 m (10 ft) 316 ss Flexible Armor B4.5 m (15 ft) 316 ss Flexible Armor C6.0 m (20 ft) 316 ss Flexible Armor D7.5 m (25 ft) 316 ss Flexible Armor E9.0 m (30 ft) 316 ss Flexible Armor F
1.5 m (5 ft) 316 ss Flexible Armor, Protective Coat G3.0 m (10 ft) 316 ss Flexible Armor, Protective Coat H4.5 m (15 ft) 316 ss Flexible Armor, Protective Coat J6.0 m (20 ft) 316 ss Flexible Armor, Protective Coat K7.5 m (25 ft) 316 ss Flexible Armor, Protective Coat L9.0 m (30 ft) 316 ss Flexible Armor, Protective Coat M
1. Applicable Transmitter Model Number (See Transmitter PSS)e.g., IDP10–DS1CO1F–M2L1W
Silicone Fill, Remote Seals on HI and LO Sides
e.g., PSISR–A23JSSSSC14M (Quantity of 2 Required)
Silicone FillTwo Seal System, IDP10 Transmitter
2. Pressure Seal Model Number from this PSS
PSS 2A-1Z11 APage 28
PSSCR SERIES SANITARY, TRI-CLAMP, REMOTE MOUNT PRESSURE SEALS WITH FLUSH DIAPHRAGM
The PSSCR Sanitary Series with remote mount, flush diaphragm seals are used with the IDP10, IGP20, IAP20, IGP10, and IAP10 Series Differential, Gauge, and Absolute Pressure Transmitters. These sanitary seals meet 3-A Sanitary Standards. They attach to the process connection and are secured with a Tri-Clover Tri-Clamp. Refer to Table 4 at the end of this document for the applicable transmitter product specification sheet (PSS).
Process Pressure-Temperature LimitsThe maximum working pressure of the seal process connection varies with the sanitary clamping device provided by the user. Refer to Tri-Clover Tri-Clamp standards to determine the pressure-temperature limits of the clamping system that you are using. Do not exceed the Tri-Clover Tri-Clamp limits, nor the temperature limits of the seal and capillary fill fluid selected.
Fill Fluid-Pressure Seal and Capillary
Process Wetted MaterialsHOUSING
316 ssDIAPHRAGM
316L ss or Hastelloy C276GASKET
Provided by user.
Connection to TransmitterLow volume; welded capillary connection at both instrument and seal (some models may have capillary threaded at seals).
Connection to ProcessThe diaphragm is welded to the process end of the seal, which in turn provides a sanitary process connection to mate with the process connection. The user then provides a Tri-Clover Tri-Clamp and gasket to secure the seal to the process. As stated previously, the clamp and fill fluid selected determine the pressure-temperature limits of the seal system.
Seal OrientationSeal can be on HI or LO side, or both sides, depending on transmitter model used.
Ambient Temperature Effect and Response TimeApplicable to remote, capillary connected seals only.See PERFORMANCE DATA section further in document.
Fill Fluid Temperature Limits
Neobee M20 -18 and +204°C (0 and +400°F)
PSSCR, SANITARY, REMOTE MOUNTSHOWN WITH IGP10 TRANSMITTER
PSS 2A-1Z11 APage 29
PSSCR SERIES SANITARY, TRI-CLAMP, REMOTE MOUNT PRESSURE SEALS WITH FLUSH DIAPHRAGM (Cont.)
Dimensions - Nominal See figures below and DP 020-351.
FIE
LDT
ER
MIN
ALS
FIE
LDT
ER
MIN
ALS
L-H
O-RING ANDTRI-CLAMP BY USER(REFERENCE)
PROCESS PIPEAND CONNECTIONBY USER(REFERENCE)
WELDEDCAPILLARYCONNECTION
O-RING ANDTRI-CLAMPBY USER(REFERENCE)
PSSCRSHOWN WITH
IGP10 TRANSMITTER
PSSCRSHOWN WITH
IGP20 TRANSMITTER
A
O-RING GROOVE
DIAPHRAGM
CONNECTIONWELDED AT BOTHINSTRUMENTSAND SEAL ENDS
B
PROCESSPIPE ANDCONNECTIONBY USER(REFERENCE)
Tri-Clamp Size
Dimension“A”
Dimension“B”
2-inch 2.50 in 1.20 in3-inch 3.50 in 1.20 in4-inch 4.35 in 1.20 in
PSS 2A-1Z11 APage 30
PSSCR SERIES SANITARY, TRI-CLAMP, REMOTE MOUNT PRESSURE SEALS WITH FLUSH DIAPHRAGM (Cont.)
(a) When Seal Orientation Code A is specified, then indicate that two identically model numbered seals are required.
(b) Tri-Clamp and O-ring are provided by the user.
(c) Requires silicone fill in transmitter’s sensor.
ORDERING INSTRUCTIONS
Model Code - PSSCR Pressure SealsDescription ModelSanitary Seal, Tri-Clamp, Remote Mount with Flush Diaphragm;for use with IDP10, IGP20, IAP20, IGP10 and IAP10 Transmitters.
PSSCR
Seal OrientationTwo Seal System, Balanced - Identical Seal on both Sides, IDP10 only (a) –AOne Seal System, High Side, IDP10, IGP20 or IAP20 only –BOne Seal System, Low Side, IDP10 only –COne Seal System, IGP10 or IAP10 only –D
Seal Size 2-inch Seal for use with Nominal 2-inch pipe 23-inch Seal for use with Nominal 3-inch pipe 34-inch Seal for use with Nominal 4-inch pipe 4
Process Connector (b)Tri-Clamp 1
Diaphragm Material 316L ss SHastelloy C276 C
Instrument ConnectionLow Volume, capillary welded at both instrument and seal 3
Fill Fluid - Pressure Seal and CapillaryNeobee M20, -18 and +204°C (0 and +400°F) Temperature Limits (c) 5
Capillary Internal Diameter0.040 in 4
Capillary Length and Type1.5 m (5 ft) 316 ss Flexible Armor, Protective Coat G3.0 m (10 ft) 316 ss Flexible Armor, Protective Coat H4.5 m (15 ft) 316 ss Flexible Armor, Protective Coat J6.0 m (20 ft) 316 ss Flexible Armor, Protective Coat K7.5 m (25 ft) 316 ss Flexible Armor, Protective Coat L9.0 m (30 ft) 316 ss Flexible Armor, Protective Coat M
1. Applicable Transmitter Model Number (See Transmitter PSS)e.g., IGP10–DS3EIF–M1C2W
Remote Seal, Silicone Fill
2. Pressure Seal Model Number from this PSSe.g., PSSCR–D21S354J
Silicone FillOne Remote Seal System, IGP10 Transmitter
PSS 2A-1Z11 APage 31
PSSCT SERIES SANITARY, TRI-CLAMP, DIRECT CONNECT PRESSURE SEAL WITH FLUSH DIAPHRAGM
The PSSCT Sanitary Series with direct mount, flush diaphragm seals are used with the IDP10 and IGP20 Differential Pressure and Gauge Pressure Transmitters. These seals meet 3-A sanitary standards. They attach to the process connection and are secured with a Tri-Clover Tri-Clamp. Refer to the applicable transmitter PSS in Table 4 at the end of this document.
Process Pressure-Temperature LimitsThe maximum working pressure of the seal process connection varies with the sanitary clamping device provided by the user. Refer to Tri-Clover Tri-Clamp standards to determine the pressure-temperature limits of the clamping system that you are using. Do not exceed the Tri-Clover Tri-Clamp limits, nor the temperature limits of the seal fill fluid selected.
Fill Fluid - Pressure Seal
Process Wetted MaterialsHOUSING
316 ssDIAPHRAGM
316L ssGASKET
Provided by user.
Connection to TransmitterSeal bolted to high pressure side of transmitter and sealed with a metallic self-energizing O-ring, thus forming an integral transmitter/seal assembly.
Connection to ProcessThe user provides a Tri-Clamp and gasket to secure the seal to the mating process connector. As stated previously, the clamp size and fill fluid determine the pressure-temperature limits of the seal system.
Seal OrientationSeal can be on HI side only.
Approximate Mass3.5 to 6.5 kg (7.8 to 14.2 lb),depending on transmitter and seal configuration selected.
Ambient Temperature Effect - Transmitter with PSSCT Seal (see tables below)
Total Effect for a 28°C (50°F) Change within Normal Operating Conditions
Values of “X” for Ambient Temperature Effect Specifications
Fill Fluid Temperature Limits
Neobee M20 -18 and +204°C (0 and +400°F)
PSSCT, SANITARY, DIRECT CONNECTSHOWN WITH IDP10 TRANSMITTER
Transmitter Span Limit
Code (a)
Total Ambient Temperature Effect for Transmitters with:
Electronics Versions“-D,” “-T”, “-F”, and “-V” (b)
Electronics Version“-A” only (b)
B and C ±(0.03% URL + 0.060% Span + “X”) ±(0.03% URL + 0.20% Span + “X”)D only ±(0.05% URL + 0.045% Span + “X”) ±(0.05% URL + 0.18% Span + “X”)E only ±(0.08% URL + 0.025% Span + “X”) ±(0.08% URL + 0.15% Span + “X”)
(a) Pressure seals are not applicable to transmitter Span Limit Code A.(b) URL, Span, and “X” must be in identical units. See table below for Values of “X”.
Pressure Seal Model
ConnectionSize
SealFill Fluid
Value of “X” for Transmitterwith a PSSCT Seal
mmH2O inH2OPSSCT-B21S55 2-in Tri-Clamp Neobee M20 107 4.2PSSCT-B31S55 3-in Tri-Clamp Neobee M20 51 2.0
PSS 2A-1Z11 APage 32
PSSCT SERIES SANITARY, TRI-CLAMP, DIRECT CONNECT PRESSURE SEAL WITH FLUSH DIAPHRAGM (Cont.)
Dimensions - Nominal See figure below and DP 020-355.
Model Code - PSSCT Pressure Seals
(a) Temperature limit is 204°C (400°F) when used with IDP10 or IGP20 Transmitter.
ORDERING INSTRUCTIONS
Description ModelSanitary Seal, Tri-Clamp, for Sanitary Piping
for Direct Connection to IDP10 or IGP20 TransmittersPSSCT
Seal OrientationOne Seal System, High Side, IDP10 or IGP20 -B
Structure Code - Connection Size and Type, Diaphragm MaterialConnection Connection Diaphragm
Size Type Material2 inch Tri-Clamp 316L ss 21S3 inch Tri-Clamp 316L ss 31S
Instrument ConnectionBolted, with Metal Self-Energizing O-ring 5
Fill Fluid - Pressure SealNeobee M20, -18 and +204°C (0 and 400°F) Temperature Limits 5
(Requires silicone fill in transmitter’s sensor)
FIE
LDT
ER
MIN
ALS
L-H
LOW PRESSURECONNECTION (IDP10 ONLY)
1606.3
A
IDP10 TRANSMITTER SHOWN
2- OR 3- INCH TRI-CLAMPAND GASKET, AND MATING PROCESS CONNECTOR (BY USER)
MAXIMUM1576.2
Tri-ClampSize
Dimension“A”
2-inch 2.50 in3-inch 3.60 in
1. Applicable Transmitter Model Number (see Transmitter PSS)e.g., IGP20–D12F1C01F
Level Seal, HI Side
2. Pressure Seal Model Number from this PSSe.g., PSSCT–B21S155
HI Side Seal, IGP20 Transmitter
Silicone Fill
Neobee Fill
PSS 2A-1Z11 APage 33
PSSSR AND PSSST SERIES SANITARY, TRI-CLAMP, REMOTE MOUNT OR DIRECT CONNECT TO STANDARD SPUD OR MINI SPUD
The PSSSR pressure seals are remote mounted, capillary connected, sanitary seals with extended diaphragm for installation on mating tank spuds. They are used with IDP10, IGP10, IGP20, IAP10, and IAP20 Series DP, GP, and AP transmitters. The PSSST pressure seals are direct-connect extended diaphragm sanitary seals for tank spud installations. They are used with IDP10 and IGP20 Series DP and GP transmitters. For transmitter specifications, see applicable transmitter PSS in Table 4.
Process Pressure-Temperature LimitsThe maximum working pressure of the seal process connection varies with the sanitary clamping device. Refer to Tri-Clover Tri-Clamp standards to determine the pressure-temperature limits of the clamping system that you are using. Do not exceed the Tri-Clover Tri-Clamp limits, nor the temperature limits of the seal and capillary fill fluid selected.
Fill Fluid-Pressure Seal and Capillary
Process Wetted MaterialsHOUSING
316 ssDIAPHRAGM
316L ssGASKET
EPDM
Connection to TransmitterPSSSR
Low volume, metal-to-metal threaded seal at transmitter. Welded at the seal. Capillary has 0.04-in inside diameter.
PSSSTBolted, with self-energizing O-ring.
Connection to ProcessThe seal is connected to the mating tank spud using a Tri-Clamp. The clamp (with gasket) is provided as part of the transmitter/seal assembly. Tank spuds are offered as accessories for users not having an existing spud. As stated previously, the clamp and fill fluid selected determine the pressure-temperature limits of the seal system.
Seal OrientationSeal can be on HI or LO side, or on both sides as a balanced two-seal system, depending on transmitter model used. See Model Code.
Ambient Temperature Effect and Response TimeApplicable to remote, capillary connected seals only. See PERFORMANCE DATA section further in document.
Approximate MassTransmitter with Direct Connect Seal
3.5 to 7.5 kg (7.8 to 16.5 lb), depending onconfiguration selected
Transmitter with Remote Mount Seal1.5 to 2.8 kg (3.3 to 6.2 lb) for
IAP10/IGP10 Transmitters, without seal orcapillary, depending on configuration selected
3.5 to 5.5 kg (7.8 to 12.1 lb) forIAP20/IGP20/IDP10 transmitters, without sealor capillary, depending on configuration selected
PSSSR, SANITARY, TRI-CLAMPSHOWN WITH IGP10 TRANSMITTER
PSSST, SANITARY, TRI-CLAMP/SPUDSHOWN WITH IDP10 TRANSMITTER
Fill Fluid Temperature Limits
Neobee M20 -18 and +204°C (0 and +400°F)
PSS 2A-1Z11 APage 34
PSSSR AND PSSST SERIES SANITARY, TRI-CLAMP, REMOTE OR DIRECT MOUNTED TO STANDARD SPUD OR MINI SPUD (Cont.)
Ambient Temperature Effect - Transmitter with PSSST Seal (see tables below)
Total Effect for a 28°C (50°F) Change within Normal Operating Conditions
Values of “X” for Ambient Temperature Effect Specifications
Dimensions - Nominal See below. Also see DP 020-353 for PSSSR and DP 020-354 for PSSST.
Transmitter Span Limit
Code (a)
Total Ambient Temperature Effect for Transmitter with PSSST Seal and:
Electronics Versions“-D,” “-T”, “-F”, and “-V” (b)
Electronics Version“-A” only (b)
B and C ±(0.03% URL + 0.060% Span + “X”) ±(0.03% URL + 0.20% Span + “X”)D only ±(0.05% URL + 0.045% Span + “X”) ±(0.05% URL + 0.18% Span + “X”)E only ±(0.08% URL + 0.025% Span + “X”) ±(0.08% URL + 0.15% Span + “X”)
(a) Pressure seals are not applicable to transmitter Span Limit Code A.(b) URL, Span, and “X” must be in identical units. See table below for Values of “X”.
Pressure Seal Model
SpudSize
SealFill Fluid
Value of “X” for Transmitterwith a PSSST Seal
mmH2O inH2OPSSST-.2S. 2-in Mini Neobee M20 107 4.2PSSST-.4S. 4-in Standard Neobee M20 13 0.5
SpudSize (a)
Extension(Nominal)
ModelCode
Dimensions (b)
A B C
2 in 1 1/2 in 2S2 2.13 3.05 1.502 in 6 in 2S6 2.13 3.05 6.002 in 9 in 2S9 2.13 3.05 9.004 in 2 in 4S2 4.08 5.22 2.034 in 6 in 4S6 4.08 5.22 6.03
(a) 2-inch Mini-Spud; 4-inch Standard Spud.(b) Dimensions are in inches.
FIE
LDT
ER
MIN
ALS
L-H
A
MAXIMUM
1606.3
B
IDP10 TRANSMITTERSHOWN WITH PSSSTPRESSURE SEAL
TRI-CLAMPCONNECTION
CCAPILLARY FOR PSSSR WELDED TO REMOTETRANSMITTER AND SEAL
EXTENSION
1576.2
EXTENSIONC
A B
PSS 2A-1Z11 APage 35
PSSSR AND PSSST SERIES SANITARY, TRI-CLAMP, REMOTE MOUNT OR DIRECT CONNECT TO STANDARD SPUD OR MINI SPUD (Cont.)
(a) Clamp and O-ring are supplied with transmitter/seal assembly. Tank spuds can be specified separately. See ACCESSORIES section.(b) Seal Orientation Codes -A, -C, and -D are not available with PSSST Pressure Seal.(c) Requires silicone fill in the transmitter’s sensor.
NOTESee next page for tank spud accessories used with the PSSSR and PSSST Pressure Seals.
Model Code - PSSSR and PSSST Pressure SealsDescription ModelRemote Mount, Extended Diaphragm, Sanitary Seal for Spud Mounting; (a)
for use with IDP10, IGP20, IAP20, IAP10, and IGP10 TransmittersPSSSR
Direct Connect, Extended Diaphragm, Sanitary Seal for Spud Mounting (a);for use with IDP10 and IGP20 Transmitters
PSSST
Seal Orientation Two Seal System, Balanced, Identical Seals on both sides of IDP10 only (b) –AOne Seal System, High Side
With PSSSR: High side of IDP10, IGP20, or IAP20 onlyWith PSSST: High side of IDP10 or IGP20 only
–B
One Seal System, Low Side, IDP10 only (b) –COne Seal System, IGP10 or IAP10 only (b) –D
Structure Code - Seal/Tank Spud Size, Diaphragm Material, and Extension LengthSeal/Tank Diaphragm ExtensionSpud Size Material Length2 in/Mini-Spud 316L ss 1-1/2 inch 2S22 in/Mini-Spud 316L ss 6 inches 2S62 in/Mini-Spud 316L ss 9 inches 2S94 in/Standard Spud 316L ss 2 inches 4S24 in/Standard Spud 316L ss 6 inches 4S6
Instrument ConnectionPSSSR Only - Capillary welded at both transmitter and seal 3PSSST Only - Bolted, with Metal Self-Energizing O-ring 5
Fill Fluid - Pressure Seal, and Capillary as applicableNeobee M20, -18 and +204°C (0 and +400°F) Temperature Limits (c) 5
Capillary Internal Diameter - Select with PSSSR Seals Only0.040 in I.D. 4
Capillary Length and Type - Select with PSSSR Seals Only1.5 m (5 ft) 316 ss Flexible Armor, Protective Coat G3.0 m (10 ft) 316 ss Flexible Armor, Protective Coat H4.5 m (15 ft) 316 ss Flexible Armor, Protective Coat J6.0 m (20 ft) 316 ss Flexible Armor, Protective Coat K7.5 m (25 ft) 316 ss Flexible Armor, Protective Coat L9.0 m (30 ft) 316 ss Flexible Armor, Protective Coat M
Examples: PSSSR-A4S2354K; PSSST-B2S255
PSS 2A-1Z11 APage 36
PSSSR AND PSSST SERIES SANITARY, TRI-CLAMP, REMOTE MOUNT OR DIRECT CONNECT TO STANDARD SPUD OR MINI SPUD (Cont.)
ACCESSORIES
ORDERING INSTRUCTIONS
DescriptionFor Use with
Structure CodePart Number
(a)
Tank Spud - 1-1/2 inch Extension 2S2 N1212GGTank Spud - 6 inch Extension 2S6 N1214BPTank Spud - 9 inch Extension 2S9 N1214BQTank Spud - 2 inch Extension 4S2 N1212AUTank Spud - 6 inch Extension 4S6 N1212AV(a) See accessory dimensions below
BC
AWEEPHOLE
Tank Spud Description
Use with Structure
Code
Dimensions in inchesPart
NumberA B C
1 1/2 inch Ext. 2S2 1.50 3.05 3.73 N1212GG6 inch Ext. 2S6 6.00 3.05 3.73 N1214BP9 inch Ext. 2S9 9.00 3.05 3.73 N1214BQ2 inch Ext. 4S2 2.10 5.22 5.98 N1212AU6 inch Ext. 4S6 6.10 5.22 5.98 N1212AV
1. Applicable Transmitter Model Number (see Transmitter PSS)e.g., IGP10–DM6C1F-L1K1W
Mini Tank Spud Seal, 6-inch Extension, Neobee Fill
2. Pressure Seal Model Number from this PSSe.g., PSSSR–D2S6354H
Mini-Tank Spud Seal, 6-inch Extension
,
Neobee Fill
3. Accessories - Reference Part Numbers in tables above.
PSS 2A-1Z11 APage 37
PERFORMANCE DATA
Ambient Temperature Effect and Response TimeThe tables that follow provide ambient temperature effect and response time estimates when remote, capillary connected pressure seals are used. The values in the table were calculated using the following variables, as applicable: fluid type and expansion rate, diaphragm spring rate, length and I.D. of capillary, fluid volume in sensor, seal, and capillary, fluid viscosity, and temperature.
The error values in the temperature effect tables assume that the transmitter, capillary, and single seal are all exposed to the same temperaturechange. Therefore, when two seals are used, the error from one seal tends to cancel out the error
from the second seal. For this reason, the ambient temperature effect tables that follow relate to a single remote seal only. The response time table, however, indicates values when dual seals are used.
The error values in the tables below are additive to the transmitter errors except when the transmitter is used with a PSFLT Direct Mount Seal. In this case, the ambient temperature effect is defined for the assembled transmitter-seal system. See previous Model PSFLT, PSSCT, or PSSST sections. Otherwise, refer to the applicable transmitter PSS for “transmitter only” effects with other than the above-mentioned seals.
Ambient Temperature Effect Using DC200, 10 cSt SILICONE M20 FILL - Seal and Capillary (316L ss Seal and Diaphragm)
Pressure Seal Model
Process Connector or Diaphragm Size
Internal Diameter of
Capillary
Effect per 28°C (50°F) Change Is:
for a 1.5 m (5 ft)Capillary Length
for each additional1.5 m (5 ft) Capillary
mmH2O inH2O mmH2O inH2O
PSFPS- 2 2-in ANSI or50 mm BS/DIN Flange
0.027 in 51 2.0 10 0.40.040 in 61 2.4 20 0.80.062 in 91 3.6 48 1.9
PSFPS- 3 3-in ANSI or80 mm BS/DIN Flange
0.027 in 13 0.5 3 0.10.040 in 15 0.6 3 0.10.062 in 20 0.8 10 0.4
PSFES- 2 2-in ANSI or50 mm BS/DIN Flange
0.027 in 160 6.3 36 1.40.040 in 203 8.0 81 3.20.062 in 318 12.5 193 7.6
PSFES- 3 3-in ANSI or80 mm BS/DIN Flange
0.027 in 69 2.7 10 0.40.040 in 81 3.2 25 1.00.062 in 127 5.0 64 2.5
PSFES- 4 4-in ANSI or80 mm BS/DIN Flange
0.027 in 13 0.5 3 0.10.040 in 15 0.6 3 0.10.062 in 18 0.7 5 0.2
PSFAR- 2PSTAR- 2PSISR - 2
2.4-in Diaphragm 0.027 in 178 7.0 25 1.00.040 in 201 7.9 43 1.70.062 in 267 10.5 109 4.3
PSFAR- 3PSTAR- 3
–
3-in Diaphragm 0.027 in 51 2 8 0.30.040 in 58 2.3 13 0.50.062 in 76 3 33 1.3
PSFAR- 4PSTAR- 4
–
4-in Diaphragm 0.027 in 13 0.5 3 0.10.040 in 13 0.5 3 0.10.062 in 15 0.6 5 0.2
PSS 2A-1Z11 APage 38
PERFORMANCE DATA (Cont.)
Ambient Temperature Effect Using FC77 FLUORINERT FILL - Seal and Capillary (316L ss Seal and Diaphragm)
Pressure Seal Model
Process Connector or Diaphragm Size
Internal Diameter of
Capillary
Effect per 28°C (50°F) Change Is:
for a 1.5 m (5 ft)Capillary Length
for each additional1.5 m (5 ft) Capillary
mmH2O inH2O mmH2O inH2OPSFPS- 2 2-in ANSI or
50 mm BS/DIN Flange0.027 in 66 2.6 13 0.50.040 in 81 3.2 28 1.10.062 in 121 4.8 66 2.6
PSFPS- 3 3-in ANSI or80 mm BS/DIN Flange
0.027 in 15 0.6 3 0.10.040 in 20 0.8 5 0.20.062 in 25 1.0 10 0.4
PSFES- 2 2-in ANSI or50 mm BS/DIN Flange
0.027 in 216 8.5 43 1.70.040 in 272 10.7 107 4.20.062 in 422 16.6 257 10.1
PSFES- 3 3-in ANSI or80 mm BS/DIN Flange
0.027 in 91 3.6 17 0.70.040 in 109 4.3 33 1.30.062 in 157 6.2 81 3.2
PSFES- 4 4-in ANSI or80 mm BS/DIN Flange
0.027 in 18 0.7 3 0.10.040 in 20 0.8 3 0.10.062 in 23 0.9 5 0.2
PSFAR- 2PSTAR- 2PSISR - 2
2.4-in Diaphragm 0.027 in 234 9.2 28 1.10.040 in 267 10.5 56 2.20.062 in 353 13.9 168 6.6
PSFAR- 3PSTAR- 3
–
3-in Diaphragm 0.027 in 69 2.7 8 0.30.040 in 76 3.0 18 0.70.062 in 102 4.0 43 1.7
PSFAR- 4PSTAR- 4
–
4-in Diaphragm 0.027 in 15 0.6 3 0.10.040 in 18 0.7 3 0.20.062 in 20 0.8 5 0.2
Ambient Temperature Effect Using DC200, 3 cSt SILICONE FILL - Seal and Capillary (316L ss Seal and Diaphragm)PSFPS- 2 2-in ANSI or
50 mm BS/DIN Flange0.027 in 51 2.0 10 0.40.040 in 64 2.5 23 0.90.062 in 94 3.7 53 2.1
PSFPS- 3 3-in ANSI or80 mm BS/DIN Flange
0.027 in 13 0.5 3 0.10.040 in 15 0.6 3 0.10.062 in 20 0.8 10 0.4
PSFES- 2 2-in ANSI or50 mm BS/DIN Flange
0.027 in 168 6.6 38 1.50.040 in 213 8.4 84 3.30.062 in 330 13.0 203 8.0
PSFES- 3 3-in ANSI or80 mm BS/DIN Flange
0.027 in 70 2.8 12 0.50.040 in 86 3.4 28 1.10.062 in 124 4.9 69 2.7
PSFES- 4 4-in ANSI or80 mm BS/DIN Flange
0.027 in 13 0.5 3 0.10.040 in 15 0.6 3 0.10.062 in 18 0.7 5 0.2
PSFAR- 2PSTAR- 2PSISR - 2
2.4-in Diaphragm 0.027 in 183 7.2 23 0.90.040 in 208 8.2 48 1.90.062 in 277 10.9 91 3.6
PSFAR- 3PSTAR- 3
–
3-in Diaphragm 0.027 in 53 2.1 5 0.20.040 in 61 2.4 13 0.50.062 in 79 3.1 33 1.3
PSFAR- 4PSTAR- 4
–
4-in Diaphragm 0.027 in 13 0.5 3 0.10.040 in 13 0.5 3 0.10.062 in 12 0.6 5 0.2
PSS 2A-1Z11 APage 39
PERFORMANCE DATA (Cont.)
Ambient Temperature Effect Using DC704 SILICONE FILL - Seal and Capillary (316L ss Seal and Diaphragm)
Ambient Temperature Effect Using NEOBEE M20 FILL - Seal and Capillary (316L ss Seal and Diaphragm)
Pressure Seal Model
Process Connector or Diaphragm Size
Internal Diameter of
Capillary
Effect per 28°C (50°F) Change Is:
for a 1.5 m (5 ft)Capillary Length
for each additional1.5 m (5 ft) Capillary
mmH2O inH2O mmH2O inH2O
PSFPS- 2 2-in ANSI or50 mm BS/DIN Flange
0.027 in N/A N/A N/A N/A0.040 in 51 2/0 18 0.70.062 in 74 2.9 41 1.6
PSFPS- 3 3-in ANSI or80 mm BS/DIN Flange
0.027 in N/A N/A N/A N/A0.040 in 13 0.5 3 0.10.062 in 15 0.6 8 0.3
PSFES- 2 2-in ANSI or50 mm BS/DIN Flange
0.027 in N/A N/A N/A N/A0.040 in 165 6.5 66 2.60.062 in 257 10.1 160 6.3
PSFES- 3 3-in ANSI or80 mm BS/DIN Flange
0.027 in N/A N/A N/A N/A0.040 in 66 2.6 0.8 200.062 in 97 3.8 1.9 48
PSFES- 4 4-in ANSI or80 mm BS/DIN Flange
0.027 in N/A N/A N/A N/A0.040 in 13 0.5 3 0.10.062 in 13 0.5 5 0.2
PSFAR- 2PSTAR- 2PSISR - 2
2.4-in Diaphragm 0.027 in N/A N/A N/A N/A0.040 in 163 6.4 38 1.50.062 in 213 8.4 89 3.5
PSFAR- 3PSTAR- 3
–
3-in Diaphragm 0.027 in N/A N/A N/A N/A0.040 in 46 1.8 10 0.40.062 in 61 2.4 25 1.0
PSFAR- 4PSTAR- 4
–
4-in Diaphragm 0.027 in N/A N/A N/A N/A0.040 in 10 0.4 3 0.10.062 in 13 0.5 5 0.2
Pressure Seal Model
Process Connector or Diaphragm Size
Internal Diameter of
Capillary
Effect per 28°C (50°F) Change Is:
for a 1.5 m (5 ft)Capillary Length
for each additional1.5 m (5 ft) Capillary
mmH2O inH2O mmH2O inH2O
PSSCR- 2Tri-Clamp2-in Diaphragm
0.040 in 174 6.8 69 2.7
PSSCR- 3Tri-Clamp3-in Diaphragm
0.040 in 69 2.7 20 0.8
PSSCR- 4Tri-Clamp4-in Diaphragm
0.040 in 13 0.5 3 0.1
PSSSR- 2Tri-Clamp2-in Diaphragm
0.040 in 174 6.8 69 2.7
PSSSR- 4Tri-Clamp4-in Diaphragm
0.040 in 13 0.5 3 0.1
PSS 2A-1Z11 APage 40
PERFORMANCE DATA (Cont.)
Typical 90% Response Time for an IDP10 Transmitter -for Transmitter Span Limit Codes B and C, and with 316 ss Dual Seals (same Model Number)
(a) Neobee M20 fill fluid has response times similar to DC200, 10 cSt Silicone.
Capillaryand SealFill Fluid
Internal Diameter of
Capillary
with 1.5 m (5 ft) Capillary Lengthat Ambient Temperature of:
9 m (30 ft) Capillary Lengthat Ambient Temperature of:
30°F 80°F 130°F 30°F 80°F 130°FDC200, 10 cStSilicone; alsoNeobee M20 (a)
0.027 in 7.0 s 3.5 s 2.0 s 41.9 s 20.9 s 11.7 s0.040 in 1.5 s 0.7 s 0.4 s 8.7 s 1.1 s 0.6 s0.062 in 0.3 s 0.1 s 0.1 s 1.5 s 0.8 s 0.4 s
FC77Fluorinert
0.027 in 1.0 s 0.5 s 0.3 s 6.0 s 3.3 s 2.0 s0.040 in 0.2 s 0.1 s 0.1 s 1.2 s 0.7 s 0.4 s0.062 in 0.0 s 0.0 s 0.0 s 0.2 s 0.1 s 0.1 s
DC200, 3 cStSilicone
0.027 in 1.8 s 1.0 s 0.6 s 11.0 s 6.0 s 3.6 s0.040 in 0.4 s 0.2 s 0.1 s 2.3 s 1.2 s 0.8 s0.062 in 0.1 s 0.0 s 0.0 s 0.4 s 0.2 s 0.1 s
DC704Silicone
0.027 in N/A N/A N/A N/A N/A N/A0.040 in 13.6 s 3.1 s 0.9 s 81.9 s 18.6 s 5.4 s0.062 in 2.4 s 0.5 s 0.2 s 14.2 s 3.2 s 0.9 s
PSS 2A-1Z11 APage 41
(a) Electronic Versions:-D = FoxCom - Digital and 4 to 20 mA-T = HART - Digital and 4 to 20 mA-F = FOUNDATION Fieldbus - Digital only-A = Analog - 4 to 20 mA-V = Analog - 1 to 5 V dc
(b) IASPT = I/A Series Pressure Transmitters.
OTHER M&I PRODUCTS
Table 4. REFERENCE PSSs - I/A Series Pressure Transmitter Family
PSS Number Description Version (a) Application
2A-1C13 A IAP10, IGP10, IAP20, IGP20 -D AP and GP2A-1C13 B IAP10, IGP10, IAP20, IGP20 -T AP and GP2A-1C13 C IAP10, IGP10, IAP20, IGP20 -A AP and GP2A-1C13 D IAP10, IGP10, IAP20, IGP20, IDP10 -V Low Power, AP, GP and DP2A-1C13 E IAP10, IGP10, IAP20, IGP20, IDP10 -F AP, GP and DP2A-1C13 F IGP10 -D, -T, -F, -A, -V High Gauge Pressure to 30 000 psi, GP only2A-1C13 G IGP25 -D, -T, -F Multirange, GP2A-1C13 H IGP50 -D, -T, -F Premium Performance, GP2A-1C13 K IAP10 and IGP10 -D, -T, -F, -A, -V Integral Sanitary Process Connectors, AP, GP2A-1C13 L IAP10 and IGP10 -D, -T, -F, -A, -V Integral Pulp/Paper Process Connectors, AP, GP2A-1C14 A IDP10 -D DP2A-1C14 B IDP10 -T DP2A-1C14 C IDP10 -A DP2A-1C14 K IDP25 -D, -T, -F Multirange, DP2A-1C14 L IDP50 -D, -T, -F Premium Performance, DP2A-1C15 A IMV30 -D, -T Multivariable, DP, T, Density, and Flow2A-1C15 B IMV25 -D, -T, -F Multivariable, P, DP, and T2A-1Z3 E PC20 Field Device Configurator All versions PC-Based Configurator for IASPT2A-1Z3 G PC50 Field Device Tool (FDT) All versions PC-Based Configurator for IASPT2A-1Z9 E IAP10, IGP10, IAP20, IGP20, IDP10 All versions Options and Accessories for IASPT (b)2A-1Z11 A IAP10, IGP10, IAP20, IGP20, IDP10 All versions Pressure Seals for IASPT
Invensys Foxboro provides a broad range of measurement and instrument products, including solutions for pressure, flow, analytical, positioners, temperature, controlling and recording. For a listing of these offerings, visit the Invensys Foxboro web site at:
www.foxboro.com/m&i.
PSS 2A-1Z11 APage 42
PSS 2A-1Z11 APage 43
PSS 2A-1Z11 APage 44
33 Commercial StreetFoxboro, MA 02035-2099United States of America
www.foxboro.comInside U.S.: 1-866-746-6477Outside U.S.: 1-508-549-2424 or contact your local Foxboro representative.Facsimile: 1-508-549-4999
Invensys, Foxboro, and I/A Series are trademarks of Invensys plc, its subsidiaries, and affiliates.All other brand names may be trademarks of their respective owners.
Copyright 2001-2003 Invensys Systems, Inc.All rights reserved
MB 010 Printed in U.S.A. 0403