42" COVERAGE
1
1
2
" 1
1
2
"
1 8
"
4"
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
SKYLINE ROOF PANEL PROFILE IMP-100 JAN 6/21 A
1
2
"
VARIES
2"
varies
EXTERIOR FACING
SKYLINE ROOF PANEL
WIDTH: 42"
PROFILE: MESA
INSULATION THICKNESS: 2", 4", 5", 6"
EXTERIOR FACING: 22ga, 24ga
INTERIOR FACING: 22ga, 24ga, 26ga
AVAILABLE FINISHES: SMOOTH/SMOOTH, LIGHT EMBOSSED
INTERIOR FACING
INSULATION
DISCLAIMER
THE DETAILS ARE PROVIDED FOR REFERENCE AND AS A GUIDELINE TO INDUSTRY ACCEPTED PRACTICES FOR SIMPLE BUILDING CONDITIONS. THESE DETAILS DO NOT ADDRESS ALL BUILDING
TYPES, CONDITIONS OR DESIGN. THE DETAILS MUST BE CHECKED FOR SUITABILITY AND MODIFIED BASED ON THE PROJECTS INTENDED USE, LOCATION, AND DESIGN LOADS.
A QUALIFIED DESIGN PROFESSIONAL SHOULD BE CONSULTED TO ENSURE MATERIALS, PRODUCTS, AND DESIGN COMPLY WITH APPLICABLE CODES, REGULATIONS, AND STANDARDS. THIS
INCLUDES CORRECT PLACEMENT OF SEALANTS, LOCATION OF AIR/VAPOUR BARRIERS AND PROJECT SPECIFIC DESIGN LOADS REQUIRED BY CODE TO MEET THE REQUIREMENTS FOR THE LOCAL
AUTHORITES HAVING JURISDICTION.
STRUCTURAL SUPPORTS AND CONNECTIONS ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY. CONSTRUCTION DRAWINGS GOVERN OVER THESE DETAILS.
ARTSPAN CONTINUES TO REFINE AND IMPROVE BASED ON CHANGES TO THE INDUSTRY. ARTSPAN AND ITS AFFILIATED COMPANIES AND SUPPLIERS RESERVE THE RIGHT TO CHANGE DETAILS,
SPECIFICATIONS, DESIGNS, OR PRODUCTS AT ANY TIME. PLEASE CONTACT ARTSPAN OR YOUR LOCAL REPRESENTATIVE FOR THE LATEST INFORMATION AVAILABLE.
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
ROOF PANEL INSTALLATION - SEQUENCE 1 IMP-101 JAN 6/21 A
SECTION A - ROOF PANEL @ OUTER FACE SECTION B - ROOF PANEL @ OUTER FACE
R
O
O
F
P
A
N
E
L
B
A
OUTER FACE
STRUCTURAL EAVE
ROOF PANELEAVE
2"
1"
ROOF PANEL
RAKE ANGLE
OUTER FACE
NOTES:
- FIELD CUT PANEL TO REQUIRED WIDTH.
- USE "C" CLAMPS TO TEMPORARILY HOLD THE CUT EDGE OF THE PANEL
TO THE RAKE ANGLE AND FASTEN AS SPECIFIED.
JOINT CENTERED ONSTRUCTURAL SUPPORT
3"x4" CONTINUOUS ANGLE@ PANEL ENDLAP.JOINT GAUGE TO MATCH PURLINS(PURLINS BY FRAMING SUPPLIER)
ALIGN PANEL AS PER SECTIONS"A" & "B" @ EAVE & RAKE
INSTALL CONCEALED FASTENER CLIPS ON THEROOT PANEL W/ BUTYL SEALANT SUBSEQUENT TORAKE FASTENING. CRIMP CLIPS WITH MANUAL SEAMING TOOL.REFER TO DETAIL IMP-102 FOR MORE INFORMATION.
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
ROOF PANEL INSTALLATION - SEQUENCE 2 IMP-101A JAN 6/21 A
3"x4" CONTINUOUS ANGLE@ PANEL ENDLAP.JOINT GAUGE TO MATCH PURLINS(PURLINS BY FRAMING SUPPLIER)
NOTES:
- STAND ON ROOF PANEL 2 TO FIRMLY SEAT ENDLAP. INSPECT THE GAP BETWEEN THE ROOF PANELS
TO ENSURE A TIGHT FIT.
- INSTALL TWO CLIPS AT PANEL ENDLAP FOLLOWING EDGE FASTENING. CRIMP BOTH CLIPS WITH MANUAL
SEAMING TOOL BEFORE INSTALLING NEXT COURSE OF PANELS.
- REFER TO DETAIL IMP-101B FOR MORE INFORMATION
ROOF PANEL 1
ROOF PANEL 2
JOINT CENTERED ONSTRUCTURAL SUPPORT
FASTEN OVERLAP JOINT @ EACHHIGH MESA INTO BACKUP PLATES
APPLY TAPE SEALANT ALONG CONNECTED EDGE
CUT UPPER COURSE OF PANEL 2 TOMATCH WIDTH OF STARTER PANEL 1
PLACE PANEL 2 INTO POSITION; ALIGN LEADING EDGEUSING SEAM CLAMP AND ATTACH CUT EDGE OF PANEL 2
TO PURLINS USING SPECIFIED FASTENER.
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
ROOF PANEL INSTALLATION - SEQUENCE 3 IMP-101B JAN 6/21 A
PANEL ATTACHMENT (1) PANEL ATTACHMENT (2)
NON-SKINNING BUTYL [SL05]
3/32"x1/2" BUTYL TAPE [SL01] USE MANUAL SEAMER TO CRIMP SEAMSFOR 12"-18" @ RIDGE, EAVES, AND END LAPS.USE ELECTRIC SEAMER ON REMAININGROOF AREAS.
NOTE:
- USE RIB CLAMPS TO PULL PANEL SIDELAPS TOGETHER.
NEXT ROOF PANEL
INSTALLED ROOF PANEL
POSITION ROOF AS SHOWN, HOOKFEMALE LAP OVER MALE LEG OF
PANEL 1 AND ROTATE INTO POSITION.
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
ROOF PANEL SIDELAP IMP-102 JAN 6/21 A
NOTE:
- USE CLAMPS TO ENSURE PROPER PANEL ALIGNMENT.
3/32"x1/2" BUTYL TAPE [SL01] OVER PANEL AND UNDERCLIP EXTEND MIN. 2" PAST EACH SIDE OF CLIP.
CLIP
CONTINUOUS 3/32"x1/2" BUTYL TAPE [SL01]
VARIES
CONCEALED FASTENER CLIP @ EACHSUPPORT LOCATION [CF02]W/ 3/32"x1/2" BUTYL TAPE [SL01]ON BOTTOM OF CLIP
NON-SKINNING BUTYL [SL05]
SD3-#14x2 1/2"-HW 3/8" (MIN. 3 PER CLIP)
STRUCTURAL SUPPORT PURLIN(BY FRAMING SUPPLIER)
3/32"x1/2" BUTYL TAPE [SL01]
HAND "CRIMP" THE STANDING SEAM @ RIDGE, ENDLAPS, AND EAVES.MECHANICALLY SEAM SUBSEQUENT TO RIDGE, RAKE, AND EAVE COMPONENT INSTALLATION.
VARIES
STRUCTURAL SUPPORT PURLIN(BY FRAMING SUPPLIER)
APPLY BUTYL SEALANT TO PANELEDGE. INSPECT SEALANT IF FACTORYINSTALLED.
SECURE TO PURLINS W/ SPECIFIEDFASTENERS.
INSTALL CFR CLIP W/ BUTYL SEALANT
HAND "CRIMP" THE STANDING RIB/CLIPASSEMBLY AT EACH CLIP LOCATION
INSTALL CONTINUOUS 3/32"x1/2" BUTYL TAPE [SL01]ON TOP OF MALE STANDING SEAM.
TILT NEXT PANEL TO BE INSTALLEDAT 45° ANGLE. ROTATE INTO POSITION.
STRUCTURAL SUPPORT PURLIN(BY FRAMING SUPPLIER)
3/32"x1/2" BUTYL TAPE [SL01]ON BOTTOM OF CLIP
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
ROOF PANEL CLIP CONNECTION IMP-102A JAN 6/21 A
INSULATED METAL ROOF PANELCONCEALED FASTENER CLIP [CF02]@ EACH SUPPORT LOCATION
V
A
R
IES
2
1
/2
" M
IN
.
B
E
A
R
IN
G
S
U
R
FA
C
E
SD3-#14x2 1/2"-HW3/8" (3 PER CLIP)
STRUCTURAL PURLIN SUPPORT(BY FRAMING SUPPLIER)
3/32"x1/2" BUTYL TAPE [SL01]ON BOTTOM OF CLIP.EXTEND TAPE 1/4" ON EACH SIDE.
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
ROOF PANEL ENDLAP IMP-103 JAN 6/21 A
3" LA
P PA
N
EL
C
U
T B
A
C
K
1"
SD3-#14x1" HW 3/8" ENDLAPENSURE FASTENERS ARE DRIVEN INTO THE
ROOF SPLICE PLATES INSIDE THE LOWER PANEL.
3/32"x2 1/2" BUTYL TAPE [SL01]
LOWER ROOF PANEL 2 1/2"
V
A
R
IES
V
A
R
IES
FIELD NOTCH TOP FLANGE
PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUSSEALANT LINES @ PANEL JOINT
UPPER ROOF PANEL
ENSURE TIGHT FIT (MAX 1/16" GAP)
SD3-#14x2 1/2"-HW3/8" (MIN. 3 PER CLIP,PER ENGINEERING DESIGN)
PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUSSEALANT LINES @ PANEL JOINT.
2) ROWS NON-SKINNING BUTYL [SL05]PROVIDE MARRIAGE BEAD FOR LOWERAND UPPER ROOF PANEL.
2
1
/2
" M
IN
.
B
E
A
R
IN
G
S
U
R
FA
C
E
2
1
/2
" M
IN
.
B
E
A
R
IN
G
S
U
R
FA
C
E
3/16"x2 1/2" BUTYL TAPE [SL04]CENTRED ON THE PURLIN/ANGLE
FASTENERS (BY FRAMING SUPPLIER)
STRUCTURAL PURLIN SUPPORT(BY FRAMING SUPPLIER)
STRUCTURAL SUPPORT ANGLE(BY FRAMING SUPPLIER)
CONCEALED FASTENER CLIP [CF02]@ EACH SUPPORT LOCATION
W/ 3/32"x1/2" BUTYL TAPE [SL01]ON BOTTOM OF CLIP.
EXTEND TAPE 1/4" ON EACH SIDE.
NOTE:
- FIELD REMOVE LINER AND INSULATION AT CUTBACK PANEL.
- END LAP STEEL LOCATION IS CRITICAL TO ROOF PANEL LENGTH.
MINIMUM ROOF SLOPES:
1/4" in 12" CONTINUOUS ROOF
1" in 12" ROOF WITH ENDLAP
1/2" in 12" ROOF WITH ENDLAP - CONSULT MANUFACTURER
ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
HIGH EAVE IMP-104 JAN 6/21 A
V
A
R
IES
VARIES
1 8
"
1
" O
FFS
E
T
FA
C
E
O
F W
A
LL P
A
N
E
L
T
O
R
O
O
F P
A
N
E
L
NOTE:
- TRANSITION FLASHING IS INSTALLED WITH A PITCH 1/2:12 GREATER THAN THE ROOF PITCH.
- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.
- TOP OF WALL PANEL TO BE PROTECTED FROM WEATHER DURING CONSTRUCTION.
STRUCTURAL EAVE SUPPORT(BY FRAMING SUPPLIER)
INSULATED METAL WALL PANEL
3/16"x7/8" BUTYL TAPE [SL02]
SDL-#14x7/8"-HW5/16"-GB9/16" @ 8" O/C
HIGH EAVE [TR02-03]
FIELD INSTALLED FILLER INSULATION(BY OTHERS)
PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUSSEALANT LINES @ PANEL JOINT
11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).
ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.
SDL-#14x7/8"-HW5/16"-GB9/16"@ 6" O.C. OUTSIDE CLOSURE
1/4"x7/8" BUTYL TAPE [SL03]
CLOSURE ZEE RIDGE CAP TRIM [TR09-02 (42" LONG)](FILL ALL GAPS WITH URETHANE POLYSEAL [SL06])
ROOF PANEL
1/4"x7/8" BUTYL TAPE[SL03]
WALL PANEL CLIP [CF01]
MINIMUM (3) FASTENERS(TYPE PER ENGINEERING DESIGN)
NON-SKINNING BUTYL [SL05]2) 1/4" BEADS BOTH LOCATIONS
SD3-#14x2 1/2"-HW3/8" (3 PER CLIP)
CONCEALED FASTENER CLIP @ EACHSUPPORT LOCATION [CF02]
3
1
/2
"
M
A
X
.
FIELD INSTALLED FILLER INSULATION(BY FRAMING SUPPLIER)
ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)
3" PA
N
EL
C
U
T B
A
C
K
1
4
"
VARIES
V
A
R
IES
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
LOW EAVE WITH GUTTER IMP-105 JAN 6/21 A
6
"
2"
1"
NOTE:
- FIELD REMOVE LINER AND INSULATION AT CUTBACK PANEL.
- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.
- TOP OF WALL PANEL TO BE PROTECTED FROM WEATHER DURING CONSTRUCTION.
INSULATED METAL WALL PANEL
WALL PANELCLIP [CF01]
STRUCTURAL EAVE SUPPORT(BY FRAMING SUPPLIER)
MINIMUM (3) FASTENERS.(TYPE PER ENGINEERING DESIGN)
PROVIDE MARRIAGE BEAD BETWEEN
CONTINUOUS SEALANT LINES @ PANEL JOINT
SD3-#14X2 1/2"-HW3/8"
(3 PER CLIP)
MIN. 2 1/2" BEARING
SURFACE
ROOF PANEL
CONCEALED FASTENER CLIP @ EACH
SUPPORT LOCATION [CF02]
3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.
SDL-#14X7/8"-HW5/16"-GB9/16"
PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUS
SEALANT LINES @ PANEL JOINT
(2) SDL-#14X7/8"-HW5/16"-GB9/16"
@ EACH SIDE OF STANDING SEAM
3/16"x7/8" BUTYL TAPE [SL02]
LOW EAVE TRIM [TR02-01]
SDL-#14X7/8"-HW5/16"-GB9/16" @ 8" O.C.
FIELD INSTALLED
FILLER INSULATION
(BY OTHERS)
GUTTER TRIM [TR13-01]
WITH CAULKING @ LAPS,
END CAPS AND FASTENERS
GUTTER INTERNAL SUPPORT
BRACKET [AC01-02] @ EACH
PANEL SEAM C/W
ADDITIONAL GUTTER SUPPORT
MID SPAN OF PANEL SEAM
SDL-#14X7/8"-HW5/16"-GB9/16"
(2) SDL-#14X7/8"-HW5/16"-GB9/16"
GUTTER STRAP [AC01-01]
@ EACH PANEL SEAM
3/16"x7/8" BUTYL TAPE [SL02]
3/32"x1/2" BUTYL TAPE
[SL01]
SDL-#14X7/8"-HW5/16"-GB9/16"
(@ EACH HIGH MESA 4" O/C)
1" OFFSET
NON-SKINNING BUTYL [SL05]
NON-SKINNING BUTYL [SL05]
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
LOW EAVE WITH TRIM IMP-105A JAN 6/21 A
2"
1"
3" PA
N
EL
C
U
T B
A
C
K
1" OFFSET
1" O
FFSET
V
A
R
IES
VARIES
NOTE:
- FIELD REMOVE LINER AND INSULATION AT CUTBACK PANEL.
- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.
- TOP OF WALL PANEL TO BE PROTECTED FROM WEATHER DURING CONSTRUCTION.
STRUCTURAL EAVE SUPPORT(BY FRAMING SUPPLIER)
MINIMUM (3) FASTENERS.(TYPE PER ENGINEERING DESIGN)
NON-SKINNING BUTYL [SL05]
SD3-#14X2 1/2"-HW3/8" (MIN. 3 PER CLIP)
MINIMUM 2 1/2" BEARING SURFACE
ROOF PANEL
PROVIDE MARRIAGE BEAD BETWEEN
CONTINUOUS SEALANT LINES
@ PANEL JOINT
CONCEALED FASTENER CLIP @
EACH SUPPORT LOCATION [CF02]
3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.
3/32"x1/2" BUTYL TAPE
[SL01]
3/16"x7/8" BUTYL TAPE
[SL02]
SDL-#14X7/8"-HW5/16"-GB9/16"
@ EACH HIGH MESA
FIELD INSTALLED FILLER INSULATION
(BY OTHERS)
LOW EAVE TRIM [TR02-01]
SDL-#14X7/8"-HW5/16"-GB9/16"
@ 8" O.C.
3/16"x7/8" BUTYL TAPE [SL02]
WALL PANEL CLIP [CF01]
INSULATED METAL WALL PANEL
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
RAKE AT WALL PANEL IMP-106 JAN 6/21 A
1"
VARIES
VARIES
NOTE:
- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.
- TOP OF WALL PANEL TO BE PROTECTED FROM WEATHER DURING CONSTRUCTION.
INSULATED METAL WALL PANELSTRUCTURAL SUPPORT
(BY FRAMING SUPPLIER)
3/16"x7/8" BUTYL TAPE [SL02]
SDL-#14X7/8"-HW5/16"-GB9/16" @ 8" O.C.
WALL PANEL CLIP [CF01]
FIELD INSTALLED FILLER INSULATION
(BY OTHERS)
RAKE TRIM [TR03-01]
RAKE CLOSURE ZEE TRIM [TR09-02A - 10']
SDL-#14X7/8"-HW5/16"-GB9/16" @ 8" O.C.
1/4"x7/8" BUTYL TAPE[SL03]
ROOF PANEL
IPF-1/4-#14x__ PC-SQ3(WITH WEATHER SEAL)@ 12" O/C
RAKE ANGLE
(BY FRAMING SUPPLIER)
NON-SKINNING BUTYL [SL05]
PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUS
SEALANT LINES @ PANEL JOINT
MINIMUM (3) FASTENERS
(TYPE PER ENGINEERING DESIGN)
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
STACK JOINT TO HIGH EAVE IMP-107 JAN 6/21 A
6" M
IN
.
18" (M
AX.)
VARIES
V
A
R
IES
NOTE:
- TRANSITION FLASHING IS INSTALLED WITH A PITCH 1/2:12 GREATER THAN THE ROOF PITCH
- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.
- TOP OF WALL PANEL TO BE PROTECTED FROM WEATHER DURING CONSTRUCTION.
INSULATED METAL WALL PANEL
WALL PANEL CLIP [CF01]
MINIMUM (3) FASTENERS
(TYPE PER ENGINEERING DESIGN)
SD3-#14X1"-PC @ 5'-0" O/C
NON-SKINNING BUTYL [SL05]
SUPPORT ANGLE
(BY FRAMING
SUPPLIER)
STRUCTURAL SUPPORT
GIRT (BY FRAMING
SUPPLIER)
NON-SKINNING BUTYL [SL05]
FIELD INSULATED FILLER INSULATION
(BY OTHERS)
WALL PANEL CLIP [CF01]
PROVIDE MARRIAGE BEAD BETWEEN
CONTINUOUS SEALANT LINES @ PANEL JOINT
URETHANE POLYSEAL [SL06]
1/4"x7/8" BUTYL TAPE [SL03]
11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).
ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.
INTERIOR COVER TRIM [TR10-03]
NON-SKINNING BUTYL [SL05]
1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4]
@ 18" O/C
PROVIDE MARRIAGE BEAD BETWEEN
CONTINUOUS SEALANT LINES @ PANEL JOINT
SD3-#14X2 1/2"-HW3/8"
(3 PER CLIP)
STRUCTURAL SUPPORT PURLIN
(BY FRAMING SUPPLIER)
TWO ROWS OF
NON-SKINNING BUTYL [SL05]
CONCEALED FASTENER CLIP @
EACH SUPPORT LOCATION [CF02]
PROVIDE MARRIAGE BEAD BETWEEN
CONTINUOUS SEALANT LINES @ PANEL JOINT
COVER TRIM [TR10-01]
1/8"Ø X 1/2" STAINLESS STEEL RIVET @ 12" O/C
HIGH SIDE FLASHING TRIM
[TR08-05-_T]
SDL-#14X7/8"-HW5/16"-GB9/16" [FST3]
@ 6" O.C. OUTSIDE CLOSURE
1/4"x7/8" BUTYL TAPE[SL03]
CLOSURE ZEE RAKE TRIM [TR09-02 (42" LONG)],
FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]
1/8"Ø X 1/2" STAINLESS STEEL RIVET
@ 18" O/C
ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)
SUPPORT ANGLE SEALED TO STRUCTURAL
SUPPORT (BY FRAMING SUPPLIER)
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
WALL TO HIGH EAVE IMP-107A JAN 6/21 A
VARIES
V
A
R
IES
NOTE:
- TRANSITION FLASHING IS INSTALLED WITH A PITCH 1/2:12 GREATER THAN THE ROOF PITCH
- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.
INSULATED METAL WALL PANEL
WALL PANEL CLIP [CF01]
MINIMUM (3) FASTENERS
(TYPE PER ENGINEERING DESIGN)
SD3-#14X1"-PC @ 5'-0" O/C
NON-SKINNING BUTYL [SL05]
STRUCTURAL SUPPORT GIRT (BY FRAMING SUPPLIER)
NON-SKINNING BUTYL [SL05]
FIELD INSTALLED FILLER INSULATION
(BY OTHERS)
URETHANE POLYSEAL [SL06]
1/4"x7/8" BUTYL TAPE [SL03]
11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).
ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.
INTERIOR COVER TRIM [TR10-04]
PROVIDE MARRIAGE BEAD BETWEEN
CONTINUOUS SEALANT LINES @ PANEL JOINT
PROVIDE MARRIAGE BEAD BETWEEN
CONTINUOUS SEALANT LINES @ PANEL JOINT
HIGH SIDE FLASHING TRIM
[TR08-05-_T]
SDL-#14X7/8"-HW5/16"-GB9/16"
@ 6" O.C. OUTSIDE CLOSURE
COVER TRIM [TR10-01]
1/8"Ø X 1/2" STAINLESS STEEL RIVET @ 18" O/C
1/4"x7/8" BUTYL TAPE[SL03]
CLOSURE ZEE RAKE TRIM [TR09-02 (42" LONG)],
FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]
1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4]
@ 18" O/C
SD3-#14X2 1/2"-HW3/8" (MIN. 3 PER CLIP)
STRUCTURAL SUPPORT PURLIN (BY FRAMING SUPPLIER)
TWO ROWS OF
NON-SKINNING BUTYL [SL05]
CONCEALED FASTENER CLIP
@ EACH SUPPORT LOCATION [CF02]
ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
WALL TO ROOF RAKE IMP-108 JAN 6/21 A
VARIES
VARIES
NOTE:
- TRANSITION FLASHING IS INSTALLED WITH A PITCH 1/2:12 GREATER THAN THE ROOF PITCH
- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.
STRUCTURAL SUPPORT (BY FRAMING SUPPLIER)
ROOF/RAKE SUPPORT (BY FRAMING SUPPLIER)
NON-SKINNING BUTYL [SL05]
IPF-1/4-#14x__ PC-SQ3(WITH WEATHER SEAL)@ 24" O/C
URETHANE POLYSEAL [SL06]
INTERIOR COVER TRIM [TR10-04]
FIELD INSTALLED FILLER INSULATION
(BY OTHERS)
NON-SKINNING BUTYL [SL05]
STRUCTURAL SUPPORT PURLIN
(BY FRAMING SUPPLIER)
SEE CONSTRUCTION DRAWINGS IF ANGLE
IS REQUIRED
SD3-#14X1"-PC @ 5'-0" O/C
MINIMUM (3) FASTENERS
(TYPE PER ENGINEERING DESIGN)
WALL PANEL CLIP [CF01]
INSULATED METAL WALL PANEL
SDL-#14x7/8"-HW5/16"-GB9/16"
@ 6" O.C. OUTSIDE CLOSURE
PROVIDE MARRIAGE BEAD BETWEEN
CONTINUOUS SEALANT LINES @ PANEL JOINT
COVER TRIM [TR10-01]
1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4] @ 18" O/C
1/4"x7/8" BUTYL TAPE[SL03]
CLOSURE ZEE RAKE TRIM [TR09-02A (10' LONG)]
FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]
WALL TO RAKE FLASHING TRIM
[TR08-04-_T]
1/4"x7/8" BUTYL TAPE[SL03]
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
RIDGE DETAIL IMP-109 JAN 6/21 A
VARIES,
SEE CO
N
STRU
CTIO
N
D
RAW
IN
G
S
1" OFFSET ℄
RIDGE TO PANEL
VARIES
V
A
R
IES
EXTERIOR RIDGE CAP [TR11-01]
1/4"x7/8" BUTYL TAPE [SL03]
CONCEALED FASTENER CLIP
@ EACH SUPPORT LOCATION [CF02]
3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.
INSULATED METAL
ROOF PANEL
℄ RIDGE
EXPANDABLE FOAM INSULATION
(BY OTHERS)
SDL-#14X7/8"-HW5/16"-GB9/16"
@ 6" O.C. OUTSIDE CLOSURE
CLOSURE ZEE RIDGE CAP [TR09-02 (42" LONG)],
FILL ALL GAPS WITH URETHANE POLYSEAL [SL06]
NOTE:
- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.
- REDUCE PANEL EXTENSION IN SNOW DRIFT CONDITIONS.
PROVIDE MARRIAGE BEAD
BETWEEN CONTINUOUS SEALANT
LINES @ PANEL JOINT
SD3-#14X2 1/2"-HW3/8" (3 PER CLIP)
STRUCTURAL SUPPORT
(BY FRAMING SUPPLIER)
11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).
ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.
PROVIDE MARRIAGE BEAD
BETWEEN CONTINUOUS
SEALANT LINES @ PANEL JOINT
TWO ROWS OF
NON-SKINNING BUTYL [SL05]
SD3-#14x1" PC [FST6-3]
@ 60" O/C
PROVIDE MARRIAGE BEAD
BETWEEN CONTINUOUS
SEALANT LINES
@ PANEL JOINT
INTERIOR RIDGE CAP
TRIM [TR11-02-15L]
ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
HIP DETAIL IMP-109A JAN 6/21 A
RUN
RISE
VARIES
2"
(51)
V
A
R
IES
℄ HIP
NOTE:
- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.
EXTERIOR RIDGE CAP [TR11-01]
1/4"x7/8" BUTYL TAPE [SL03]
CONCEALED FASTENER CLIP
@ EACH SUPPORT LOCATION [CF02]
3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.
INSULATED METAL
ROOF PANEL
EXPANDABLE FOAM INSULATION
(BY OTHERS)
SDL-#14X7/8"-HW5/16"-GB9/16"
@ 6" O.C. OUTSIDE CLOSURE
FIELD FABRICATED ZEE CLOSURE RIDGE CAP.
CUT & NOTCH [TR09-02A - 10'] RAKE ZEE TO FIT
BETWEEN PANEL RIBS (FILL ALL GAPS WITH
URETHANE POLYSEAL [SL06]).
11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).
ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.
PROVIDE MARRIAGE BEAD BETWEEN
CONTINUOUS SEALANT LINES
@ PANEL JOINT
TWO ROWS OF
NON-SKINNING BUTYL [SL05]
HIP PLATE
(BY FRAMING SUPPLIER)
PROVIDE MARRIAGE BEAD
BETWEEN CONTINUOUS SEALANT
LINES @ PANEL JOINT
SD3-#14X2 1/2"-HW3/8" (MIN. 3 PER CLIP)
STRUCTURAL SUPPORT
(BY FRAMING SUPPLIER)
PROVIDE MARRIAGE BEAD BETWEEN
CONTINUOUS SEALANT LINES @ PANEL JOINT
ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
VALLEY DETAIL IMP-110 JAN 6/21 A
1"
9" M
IN
.
3"
3
"
3"
V
A
R
IES
V
A
R
IES
NOTE:
- VALLEY DETAIL DOES NOT APPLY FOR DORMER CONDITIONS.
- VALLEY CONDITIONS ARE NOT RECOMMENDED FOR APPLICATIONS WITH ROOF PITCH LESS THAN 3:12.
- THE VALLEY PAN WIDTH VARIES WITH THE ROOF'S DRAINAGE REQUIREMENTS.
- FILLER INSULATION MATERIAL AND APPLICATION IS SPECIFIED BY THE PROJECT DESIGNER.
- RECOMMENDED VALLEY PAN IS 16 GA. MIN. STEEL, WELDED WATER-TIGHT AND COATED OR LINED WITH MEMBRANE.
INSTALLATION SEQUENCE:
1. INSTALL STRUCTURAL VALLEY SUPPORT PLATE.
2. FASTEN VALLEY SUPPORT ZEE E/S TO VALLEY PLATE.
3. FILL VOID WITH INSULATION.
4. INSTALL VALLEY TRIM.
5. INSTALL SEALANTS.
6. FIELD CUT PANEL AND REMOVE CUT BACK.
7. FASTEN VALLEY ASSEMBLY.
INSULATED METAL
ROOF PANEL
FIELD INSTALLED INSULATION
(BY OTHERS)
3/32"x1/2" BUTYL TAPE [SL01]
@ SIDE JOINT
SD3-#14x1"-HW3/8" [FST2-3]
TRIPLE BEAD 3/16"x2 1/2" BUTYL TAPE [SL04]
CONCEALED FASTENER CLIP
@ EACH PANEL SIDELAP [CF02]
3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.
INSULATED METAL
ROOF PANEL
PROVIDE MARRIAGE BEAD
BETWEEN CONTINUOUS
SEALANT LINES
@ PANEL JOINT
NON-SKINNING BUTYL [SL05]
STRUCTURAL VALLEY SUPPORT PLATE
(BY FRAMING SUPPLIER)
STRUCTURAL SUPPORT
(BY FRAMING SUPPLIER)
VALLEY PAN TRIM
[TR12-01]
RIGID INSULATION
(BY OTHERS)
3" FIELD CUT BACK
FOAM/ LINER SKIN
VALLEY SUPPORT ZEE
[TR12-02_T]
SD3-#14X1"-PC [FST6-3]
(2) PER CONNECTION
SD3-#14X2 1/2"-HW3/8"
(MIN. 3 PER CLIP)
PROVIDE MARRIAGE BEAD
BETWEEN CONTINUOUS
SEALANT LINES
@ PANEL JOINT
6
4
7
5
3
1
2
MINIMUM ROOF SLOPE FOR VALLEYS:
3" in 12"
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
TRANSITION CONT. WALL TO ROOF RAKE IMP-111 JAN 6/21 A
VARIES
SEAL VOID WITH URETHANE POLYSEAL [SL06]
SDL-#14X7/8"-HW5/16"-GB9/16" [FST3]
@ 8" O.C.
COUNTER FLASHING [TR08-03]
SDL-#14X7/8"-HW5/16"-GB9/16" [FST3]
@ 6" O.C.
RAKE TRANSITION TRIM [TR08-02]
CLOSURE ZEE RAKE TRIM [TR09-02A (10' LONG)],
FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]
INSULATED METAL
ROOF PANEL
1/4"x7/8" BUTYL TAPE[SL03]
CONTINUOUS NON-SKINNING BUTYL [SL05]
3/16"x7/8" BUTYL TAPE [SL02]
FIELD INSTALLED FILLER INSULATION
(BY OTHERS)
IPF-1/4-#14x__ PC-SQ3(WITH WEATHER SEAL)@ 24" O/C
NON-SKINNING BUTYL [SL05]
ROOF/RAKE SUPPORT ANGLE WITH SEALANT
(BY FRAMING SUPPLIER)
STRUCTURAL EAVE SUPPORT
(BY FRAMING SUPPLIER)
INSULATED METAL WALL PANEL
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
TRANSITION CONT. WALL TO HIGH EAVE IMP-111A JAN 6/21 A
V
A
R
IES
VARIES
SEAL VOID WITH URETHANE POLYSEAL [SL06]
COUNTER FLASHING [TR08-03]
SDL-#14X7/8"-HW5/16"-GB9/16" @ 8" O.C.
HIGH SIDE TRIM [TR08-01]
SDL-#14X7/8"-HW5/16"-GB9/16"
@ 6" O.C. OUTSIDE CLOSURE
1/4"x7/8" BUTYL TAPE[SL03]
CLOSURE ZEE RAKE TRIM [TR09-02 (42" LONG)],
FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]
1/8"Ø X 1/2" STAINLESS
STEEL RIVET [FST4] @ 18" O/C
CONCEALED FASTENER CLIP @
EACH SUPPORT LOCATION [CF02]
3/32"x1/2" BUTYL TAPE [SL01] ON BOTTOMOF CLIP. EXTEND TAPE 1/4" ON EACH SIDE.
TWO ROWS OF
NON-SKINNING BUTYL [SL05]
SD3-#14X2 1/2"-HW3/8"
(MIN. 2 PER CLIP)
STRUCTURAL SUPPORT
(BY FRAMING SUPPLIER)
CONTINUOUS NON-SKINNING BUTYL[SL05]
3/16"x7/8" BUTYL TAPE [SL02]
FIELD INSTALLED FILLER INSULATION
(BY OTHERS)
URETHANE POLYSEAL [SL06]
1/4"x7/8" BUTYL TAPE[SL03]
11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).
ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.
INTERIOR COVER TRIM [TR10-03]
1/8"Ø X 1/2" STAINLESS
STEEL RIVET [FST4] @ 18" O/C
NON-SKINNING BUTYL [SL05]
ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)
INSULATED METAL WALL PANEL
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
TRANSITION MASONRY WALL TO HIGH EAVE IMP-112 JAN 6/21 A
V
A
R
IES
SEAL VOID WITH URETHANE POLYSEAL [SL06]
COUNTER FLASHING
[TR08-03]
#14 MASONRY FASTENER
@ 8" O.C.
HIGH SIDE TRIM
[TR08-01]
SDL-#14X7/8"-HW5/16"-GB9/16"
@ 6" O.C. OUTSIDE CLOSURE
1/4"x7/8" BUTYL TAPE[SL03]
CLOSURE ZEE RAKE TRIM [TR09-02 (42" LONG)],
FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]
1/8"Ø X 1/2" STAINLESS
STEEL RIVET [FST4] @ 18" O/C
CONCEALED FASTENER CLIP @ EACH
SUPPORT LOCATION [CF02]
TWO ROWS OF
NON-SKINNING BUTYL [SL05]
SD3-#14X2 1/2"-HW3/8" (MIN. 3 PER CLIP)
3/16"x7/8" BUTYL TAPE [SL02]
FIELD INSTALLED FILLER INSULATION
(BY OTHERS)
URETHANE POLYSEAL [SL06]
1/4"x7/8" BUTYL TAPE[SL03]
11) SD3-#14x1" HW 5/8" (@ EACH HIGH MESA).
ENSURE FASTENERS ARE DRIVEN INTO THEROOF SPLICE PLATES INSIDE THE PANEL.
INTERIOR COVER TRIM
[TR10-03]
PROVIDE MARRIAGE BEAD BETWEEN CONTINUOUS
SEALANT LINES @ PANEL JOINT
#14 MASONRY FASTENER @ 18" O/C
NON-SKINNING BUTYL [SL05]
STRUCTURAL EAVE SUPPORT (BY FRAMING SUPPLIER)
ROOF SPLICE PLATE [CF03](FACTORY INSTALLED)
SEAL VOID WITH
URETHANE POLYSEAL [SL06]
COUNTER FLASHING
[CUSTOM]
#14 MASONRY FASTENER
@ 8" O.C.
1/8"x1/2" SAW CUT IN MASONRY.
FILL WITH POLYURETHANE CAULK
BEFORE INSERTING COUNTER
FLASHING.
OPTIONAL COUNTER FLASHING DETAIL
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP ROOF PANELS COMMERCIAL - INDUSTRIAL
TRANSITION MASONRY WALL TO RAKE IMP-112A JAN 6/21 A
SEAL VOID WITH URETHANE POLYSEAL [SL06]
#14 MASONRY FASTENER @ 8" O.C.
COUNTER FLASHING [TR08-03]
SDL-#14X7/8"-HW5/16"-GB9/16" [FST3]
@ 6" O.C.
RAKE TRANSITION TRIM [TR08-02]
CLOSURE ZEE RAKE TRIM [TR09-02A (10' LONG)],
FILL ALL GAPS W/ URETHANE POLYSEAL [SL06]
INSULATED METAL ROOF PANEL
NON-SKINNING BUTYL [SL05]
NON-SKINNING BUTYL [SL05]
FIELD INSTALLED FILLER INSULATION
(BY OTHERS)
URETHANE POLYSEAL [SL06]
IPF-1/4-#14x__ PC-SQ3(WITH WEATHER SEAL)@ 24" O/C
NON-SKINNING BUTYL [SL05]
ROOF/RAKE SUPPORT ANGLE WITH SEALANT
(BY FRAMING SUPPLIER)
STRUCTURAL EAVE SUPPORT
(BY FRAMING SUPPLIER)
SEAL VOID WITH
URETHANE POLYSEAL [SL06]
COUNTER FLASHING
[CUSTOM]
#14 MASONRY FASTENER
@ 8" O.C.
1/8"x1/2" SAW CUT IN MASONRY.
FILL WITH POLYURETHANE CAULK
BEFORE INSERTING COUNTER
FLASHING.
OPTIONAL COUNTER FLASHING DETAIL