Rugged heavy equipment comes with substantial fire safety challenges often requiring a significant investment in life and property protection. The ANSUL® CHECKFIRE 110 Detection and Actuation System offers cost-effective, single-zone detection and actuation for smaller vehicles used in the extreme environmental and physical conditions of industries like forestry, waste disposal, aviation and transit. Best-in-Class Detection and Actuation The CHECKFIRE 110 system provides electrical and/or optional pneumatic input to actuate an ANSUL fire suppression system. When fire is detected, the control module sends an electrical signal to release the gas from an expellant gas cartridge to pressurize and discharge the fire suppression system. The system is typically used with an ANSUL A-101 or LVS Vehicle Fire Suppression System for 24-hour protection of equipment. The CHECKFIRE 110 system features supervised circuits with color-coded, plug-and-play connectors for detection, release and external 12/24 VDC primary power source. Operating components include the compact control module, spot or linear thermal detection, electric manual actuators and a protracting actuation device. Two Forms of Detection for Those First Critical Seconds Detection is the critical first step in successfully dealing with the threat of fire. The CHECKFIRE 110 offers two highly-reliable forms of detection used individually or in combination. Linear Detection Wire consists of spring-steel conductors separated by a heat sensitive insulator. At the temperature rating of the wire, 356°F (180°C), the insulator melts and the two conductors make contact, sending a signal to the detection module, which signals the control module to actuate the fire suppression system. With Spot Thermal Detection, the thermal detector contacts close and signal the control module to initiate fire suppression when the temperature reaches either 250°F or 350°F (121°C or 177°C) depending on the model selected. Operator-Friendly Actuation Control The CHECKFIRE 110 control module typically can be installed within reach of the opera- tor. This provides easy access to controls while indicator LEDs and an internal sounder notify the operator of the system status. Immediate system release and alarm can be initiated using the manual-activation button with LED alarm indicator. A triple-function button can restart the time delay sequence, reset the control module or silence audible notifications during fault conditions. Designed and built for mobile applications n Cost-effective, single-zone detection and actuation n Supervised, plug-and-play circuits n LED system status indicators n Dust and water tight (IP67 rated) n Automatic or manual operation n Internal reserve power source n Compact size for console mounting n FM approved and CE marked CHECKFIRE 110 Detection & Actuation PRODUCT OVERVIEW

Upload: halien

Post on 31-Jul-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

Rugged heavy equipment comes with substantial fire safety challenges often requiring

a significant investment in life and property protection. The ANSUL® CHECKFIRE 110 Detection and Actuation System offers cost-effective, single-zone detection and actuation for smaller vehicles used in the extreme environmental and physical conditions of industries like forestry, waste disposal, aviation and transit.

Best-in-Class Detection and Actuation The CHECKFIRE 110 system provides electrical and/or optional pneumatic input to actuate an ANSUL fire suppression system. When fire is detected, the control module sends an electrical signal to release the gas from an expellant gas cartridge to pressurize and discharge the fire suppression system. The system is typically used with an ANSUL A-101 or LVS Vehicle Fire Suppression System for 24-hour protection of equipment.

The CHECKFIRE 110 system features supervised circuits with color-coded, plug-and-play connectors for detection, release and external 12/24 VDC primary power source. Operating components include the compact control module, spot or linear thermal detection, electric manual actuators and a protracting actuation device.

Two Forms of Detection for Those First Critical SecondsDetection is the critical first step in successfully dealing with the threat of fire. The CHECKFIRE 110 offers two highly-reliable forms of detection used individually or in combination. Linear Detection Wire consists of spring-steel conductors separated by a heat sensitive insulator. At the temperature rating of the wire, 356°F (180°C), the insulator melts and the two conductors make contact, sending a signal to the detection module, which signals the control module to actuate the fire suppression system. With Spot Thermal Detection, the thermal detector contacts close and signal the control module to initiate fire suppression when the temperature reaches either 250°F or 350°F (121°C or 177°C) depending on the model selected.

Operator-Friendly Actuation ControlThe CHECKFIRE 110 control module typically can be installed within reach of the opera-tor. This provides easy access to controls while indicator LEDs and an internal sounder notify the operator of the system status. Immediate system release and alarm can be initiated using the manual-activation button with LED alarm indicator. A triple-function button can restart the time delay sequence, reset the control module or silence audible notifications during fault conditions.

Designed and built for mobile applicationsn Cost-effective, single-zone detection and actuationn Supervised, plug-and-play circuitsn LED system status indicatorsn Dust and water tight (IP67 rated)n Automatic or manual operationn Internal reserve power sourcen Compact size for console mountingn FM approved and CE marked

Product overview

CHECKFIRE 110Detection & Actuation

Product overview

One Stanton Street l Marinette, WI 54143-2542, USA l +1-715-735-7411 l www.ansul.comCopyright © 2014 Tyco Fire Products LP. l All rights reserved. l Form No. F-2013357

The Ultimate Fire Suppression Solution The ANSUL brand promises a full range of quality fire protection solutions — from

automatic detection and suppression systems to a complete line of wheeled and hand

portable fire extinguishers and more. Plus, our extensive network of Authorized ANSUL

Distributors provides factory-trained professionals to serve our customers virtually

anywhere in the world.

A Passion for ProtectionDedicated customer support. Extensive product portfolio. Engineering excellence.

Trusted, proven brands. Tyco Fire Protection Products offers all of these attributes, plus

a passion for protection. It’s what drives us to create solutions to help safeguard what

matters most — your valued people, property and business.

THE CHECKFIRE 110 SySTEm CAn bE FounD on vEHIClES AnD EquIpmEnT In THESE InDuSTRIESAgriculture

Aviation

Construction

Forestry

Land fill

Public transportation

Public utilities

Waste disposal

Features n Supervised power, detection, and release circuits

n LED system status indicators

n External primary power with an internal reserve power source

n Selectable release time delay

n Automatic and/or manual actuation

n Electric “DELAY/Reset/Silence” button

n “PUSH To Activate / Alarm When Lit” electric manual activation button

n Color-coded “Plug and Play” cable connections

n Cables provide quick installation and easy replacement

n 85 dB internal sounder

n System isolate feature

n Dust and water tight (IP67 rated)

n Designed for harsh environments

n Compact size

n Adjustable mounting bracket

ApplicationThe CHECKFIRE 110 Detection and Actuation System is typically used with an ANSUL® A-101 or LVS Vehicle Fire Suppression System for 24-hour protection of equipment. The system is designed for vehicles and equipment in extreme environmental and physical conditions.

Industries where vehicles use CHECKFIRE 110 Systems:

n Forestry n Land fills

n Agriculture n Waste disposal

n Construction n Mining

n Public transportation

n Public utilities

DescriptionThe CHECKFIRE 110 Automatic Detection and Actuation System provides supervised input/output circuits to activate an ANSUL fire suppression system. Upon detecting a fire condition, the control module activates the release circuit resulting in the discharge of an expellant gas cartridge initiating fire suppression system operation.

Operating components include the control module; spot thermal detectors; linear detectors; electric manual actuators; PADs (Protracting Actuation Device); electric-pneumatic actuators; and power, detection, and release cables. The entire system is elec-tronics based for supervision, communication, and control of system components.

009257

Typical System ConnectionsThe CHECKFIRE 110 Control Module includes four cable leads with corresponding color-coded connectors for ease of installation.

System Cabling: Enables communication and control of components.

n IP67 connections

n Color-coded, anti-vibration connectors

n Integral connectors on each end of cable

n Multiple lengths for versatility

n Temperature rating: 302 °F (150 °C)

Detection Circuit Lead: Permits multiple-detection options using detection circuit cable and tees for the main detection trunk and branch lines.

n Electric manual actuators

n Linear detectors

n Spot thermal detectors

Release Circuit Lead: Connects to a maximum of 2 electric-pneu-matic actuators installed on agent tank expellant gas cartridges using release circuit cable(s), tee (needed on second tank), and release circuit drop cable(s).

External Power Circuit Lead: Provides a direct connection to the vehicle power source using power circuit cable(s) and a single fused power circuit cable.

Alarm Output Lead: Connects to vehicle electronics (by others) as needed.

CHECKFIRE 110 Detection and Actuation System

DATA SHEET

CHECKFIRE 110 SYSTEM – SAMPLE CONNECTIONS

Release CiRCuit tee

Release CiRCuit Cable

CheCkfiRe 110 ContRol module and bRaCket

Visual seal

lineaR deteCtoR

spot theRmal deteCtoRs (install with heat shield and bRaCket)

eleCtRiC manual aCtuatoR (ema) and bRaCket

bRanCh teRminatoR (on end of deteCtoR)

poweR CiRCuit Cable

fused poweR CiRCuit Cable

deteCtion CiRCuit Cable and teeseol

deViCe

aGent tank

Release CiRCuit dRop Cable

eleCtRiC- pneumatiC aCtuatoR

expellant Gas CaRtRidGe

009258

Control ModuleThe CHECKFIRE 110 Control Module communicates through the cable system to supervise and control components. Installation within reach of the operator provides easy access to operator controls. Indicator LEDs and internal sounder notify operator of system status.

n Four color-coded lead cables accessible at back of control module

n Dust and water tight (IP67 rated)

n Durable high-strength glass-filled nylon

n Surface or bracket mounted

n Two index pins on back for secure mounting

n Ambient temperature range: – 40 °F to 140 °F (– 40 °C to 60 °C)

n LED indicators provide notification of system status (internal sounder matches LED pulse rate)

n “PUSH To Activate / Alarm When Lit” manual-activation button and LED

— Provides manual actuation (immediate release)

— Indicates alarm condition

n Guard door with visual seal to protect manual-activation button

n “DELAY/Reset/Silence” button

— Restarts Time DELAY sequence when initiated before release function activates

— Resets control module

— Silences audible notifications during fault conditions

DetectionA Linear Detector with an activation temperature rating of 356 °F (180 °C) provides fire detection in the protected area. Two twisted spring steel conductors separated by a heat-sensitive insula-tor are limited to a minimum bend radius of 2 1/2 in. (64 mm). For easy installation, red color-coded connectors match the red connectors of the entire detection circuit.

Spot Thermal Detectors have the temperature rating stamped on the detector and are color-coded blue for 250 °F (121 °C) and red for 350 °F (177 °C) operating temperatures.

Electric-Pneumatic ActuatorWith a focus on ease of installation and safety, the Electric-Pneumatic Actuator reduces system complexity. The protracting actuation device (PAD) directly actuates the electric-pneumatic actuator pin eliminating the need for pneumatic actuation.

The re-designed PAD with plug-in spade connectors is easy to install and replace without tools. After plugging the PAD into the release circuit drop cable, the cable is hand-tightened to the top of the electric-pneumatic actuator.

009261

For installer safety during assembly of the Electric-Pneumatic Actuator to an expellant gas cartridge, the actuator includes a new preventor. The integral preventor reduces the possibility of attaching the actuator with the pin not completely retracted. It also provides a metal to metal seat with the expellant gas cartridge eliminating the spacing washer.

If required, optional pneumatic actuation is available.

Electric Manual ActuatorThe newly designed Electric Manual Actuator (EMA) provides electrical activation of the fire suppression system. Pulling the pin and striking the red button sends a signal to the control module for immediate actuation of the electric-pneumatic actuator. Upon actuation, the expellant gas cartridge initiates fire suppression system operation.

009262

EMAs are typically accessible from ground level and/or in a path of egress. An index nub ensures the EMA remains at the proper angle for access to the pull pin.

ANSUL®

CHECKFIRE 110CONTROL SYSTEM

POWER

DELAYRELEASE

PUSHTO ACTIVATE

DETECTION

RELEASE

“delay/Reset/silenCe” button

009259

Releasefault led

poweR ledGuaRddooR

“push to aCtiVate/alaRm when lit” button and led

deteCtionfault led

009260

System Specifications Control Module Power: 12/24 VDC nominal vehicle primary

power (24 hour operation) and: Internal 72 hour reserve power

Operating Temperature Range: – 40 °F to 140 °F (– 40 °C to 60 °C)

Shock: In accordance with UL1254

Vibration: In accordance with UL1254

Moisture and Dust: IP67 per IEC 60529

Electromagnetic Automotive EMC Directive Compliant Compatibility: (2004/104/EC)

ApprovalsFM Approved and CE marked

Ordering InformationPart No. Description

System Components439559 Control Module, CHECKFIRE 110439564 Mounting Bracket, CHECKFIRE 110/210439569 Electric-Pneumatic Actuator (normally supplied

with agent tanks)439400 Electric Manual Actuator (EMA)440537 Electric Manual Actuator Bracket

Detection Circuit Cables and Fittings439384 Cable, Detection Circuit; 2 ft (0.61 m)439386 Cable, Detection Circuit; 5 ft (1.53 m)439388 Cable, Detection Circuit; 10 ft (3.05 m)439390 Cable, Detection Circuit; 20 ft (6.10 m)440759 Cable, Detection Circuit; 30 ft (9.15 m)440762 Cable, Detection Circuit; 50 ft (15.24 m)439394 Connector, Tee, Detection Circuit (MxFxF)439396 Connector, EOL Device, Detection Circuit439398 Connector, Branch Terminator, Detection Circuit439404 Connector, Bulkhead, Detection Circuit

Part No. Description

Linear Detectors439406 Linear Detector; 2 ft (0.61 m)439478 Linear Detector; 5 ft (1.53 m)439480 Linear Detector; 10 ft (3.05 m)439408 Linear Detector; 20 ft (6.10 m)439410 Linear Detector; 30 ft (9.15 m)440765 Linear Detector; 50 ft (15.24 m)

Release Circuit Cables and Fittings439418 Cable, Release Circuit; 2 ft (0.61 m)439420 Cable, Release Circuit; 5 ft (1.53 m)439422 Cable, Release Circuit; 10 ft (3.05 m)439424 Cable, Release Circuit; 20 ft (6.10 m)439426 Cable, Release Circuit; 30 ft (9.15 m)439428 Cable, Release Circuit; 50 ft (15.24 m)439430 Cable, Release Circuit Drop; 30 in. (0.77 m)439432 Cable, Release Circuit Drop; 38 in. (0.97 m) 439434 Connector, Tee, Release Circuit (MxFxF)439436 Connector, Branch Terminator, Release Circuit439405 Connector, Bulkhead, Release and Power Circuits439448 Protracting Actuation Device (PAD), w/Spade

Connectors

Power Circuit Cables and Fittings439438 Cable, Power Circuit; 2 ft (0.61 m)439440 Cable, Power Circuit; 5 ft (1.53 m)439442 Cable, Power Circuit; 10 ft (3.05 m)439444 Cable, Power Circuit; 20 ft (6.10 m)439446 Cable, Power Circuit; 30 ft (9.15 m)440187 Cable, Power Circuit; 50 ft (15.24 m)439405 Connector, Bulkhead, Release and Power Circuits439492 Cable, Fused Power Circuit (w/Inline Fuse Holder);

3 ft (0.91 m)

Accessory Equipment438280 Spot Thermal Detector, 250 °F (121 °C) 438281 Spot Thermal Detector, 350 °F (177 °C) 440905 Spot Thermal Detector Bracket and Heat Shield

440090 Pressure Switch Shipping Assembly

440737 Double-Loop Cable Ties (Pkg. of 50)56692 Rubber Sleeve (Pkg. of 20)

440798 Label Package

440097 Detection Circuit Tester (DCT)441021 Release Circuit Tester (RCT)440912 Release Circuit Test Plug (Pkg. of 3)