product data 2000 kg / 2600 kg · klaus multiparking gmbh hermann-krum-straße 2 d-88319 aitrach...
TRANSCRIPT
40
25
45
Grounding
145
25
GF (ground floor)
LF (lower floor)
UF (upper floor)
2% 2%Water drainage
(570 for vehicle up to 5.20 m = 17’ long)550 for vehicle up to 5.00 m = 16’4’’ long
+50
+50
Deta
il doo
rsse
e pa
ge 2
and
3
Free space Detail free spacesee page 2
KLAUS Multiparking GmbHHermann-Krum-Straße 2D-88319 AitrachFon +49 (0 ) 7565 508-0Fax +49 (0 ) 7565 [email protected]
Tolerances for space requirements .Dimensions in cm.
+30
Page 1SectionDimensionsCar data
Page 2DoorWidthdimensions
Page 3WidthdimensionsApproachFree spaces
Page 4FunctionLoad plan
Page 5Technicaldata
Page 6Electrical To be perfor-med by thecustomer
Page 7Description
Tren
dVar
io43
00 | C
ode
num
ber 5
85.2
9.21
0-01
3 | V
ersio
n 05
.201
7
2000 kg / 2600 kg
PRODUCT DATA
30160
55
125100500 (520)
45
15° 6° 13°
see
table
Standard passenger cars:Limousine, station wagon, SUV, van according to clearance and maximal surface load.
Clearance profile
Width Weight Wheel load
190 cm max. 2000 kg max. 500 kg
Standard Special190 cm
max. 2600 kg max. 650 kg
Dimensions
Suitable for
For convenient use of your parking space and due to the factthat the cars keep becoming longer we recommend a pit length of 570 cm.At the transition section between pit floor and walls no hollow mouldings/coves are possible. If hollow mouldings/coves are required, the systems must be designed smaller or the pits accordingly wider.
Standard typeSpecial system: maximum load for extra charge.To follow the minimum finished dimensions, make sure to consider the tolerances according to VOB, part C (DIN 18330 and 18331) and the DIN 18202.Car width for platform width 230 cm. If wider platforms are used it is also possible to park wider cars.Potential equalization from foundation grounding connection to system (provided by the customer).Slope with drainage channel and sump.These floor areas need to be horizontal and on equal level across the full width of the pit
If sprinklers are required make sure to provide the necessary free spaces during the planning stage.
Single parking spaces can also be upgraded to handle heavier loads at a later date!
Loadable up to 2600 kg!
1 2
3
2
44
123
4
5
67
5
6
8
9
7 7
8
9
4300-175 4300-200
Height325
UF150
Car heightGF150
LF Height UFCar height
GF LF Height UFCar height
GF LF Height UFCar height
GF LF150
345 150 170 150365 150 190 150365 170 170 150380 150 205 150405 190 190 150435 205 205 150
350 150 175 175375 175 175 175380 150 205 175405 175 205 175435 205 205 175
380 150 205 205405 175 205 205420 190 205 205435 205 205 205
390 150 215 215405 165 215 215415 175 215 215435 195 215 215445 205 215 215455 215 215 215
175
200
230
240
Height
Height
Height
Height
4300-230 4300-240
TrendVario 4300 | Code number 585.29.210-013 | Version 05.2017
Garages with sliding doors (standard) | Widths dimensionsSliding door behind columns Sliding door between columns Sliding door in front of columns
Columns per each grid unit Columns per each grid unit Columns per each grid unit
Columns every second grid unit Columns every second grid unit Columns every second grid unit
175175200200230
GT325/345/365/405380/435350/375380/405/435380/405/420/435
Height210220210220220
H1
240 390/405/415/435/445/455 230
43004300430043004300
Type
4300
175175200200230
GT325/345/365/405380/435350/375380/405/435380/405/420/435
Height220230220230230
H1
240 390/405/415/435/445/455 240
43004300430043004300
Type
4300
175175200200230
GT325/345/365/405380/435350/375380/405/435380/405/420/435
Height220230220230230
H1
240 390/405/415/435/445/455 240
43004300430043004300
Type
4300
550 (570)550 (570) 550 (570)
Heigh
tGT
Heigh
tGT
25
H1H1
25
Heigh
tGT
H1
25
30
2030
55
2030
55
Free spaceFree spaceFree space 30 45
55
10
Not available!
C
230240250260
250260270280
230240250260
270 290 270
B1 B2Usable platform width250260270280290
RB230240250260
250260270280
230240250260
270 290 270
B1 B2Usable platform width250260270280290
RB
RB RB RB
(B2) 20B1 B2No. of grids x RB + 20
RB RB RB
(B2) 20B1 B2
1010
Carriageway in accordancewith local regulations
Carriageway in accordancewith local regulations
(25)
No. of grids x RB + 20
1
Carriageway in accordancewith local regulations
500520540560
480500520540
580 560
B3 B4
230240250260270
Usable platform width250260270280290
RB500520540560
480500520540
580 560
B3 B4230240250260270
Usable platform width250260270280290
RB500520540560
480500520540
580 560
B3 B5230240250260270
Usable platform width250260270280290
RB
10RB RB RB
(B4) 20B3 B4
No. of grids x RB + 20
RB RBRB RB RB
(B4) 20B3 B4
No. of grids x RB + 20
RB RB RB
(B4) 20B3 B4No. of grids x RB + 20
RB
(25)10 10
Carriageway in accordancewith local regulations
Carriageway in accordancewith local regulations
C
RB = Grid unit width must strictly conform to dimensions quoted!Only applies to manually operated doors. The electrically driven doors must have 35 cm.
According to the BGR 232, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning,and then once a year, the gate has to be inspected by an expert and the findings entered in the inspection book. The inspection hasto be carried out independent of any maintenance work.For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm.Please consider adjoining grids. Problems may occur if smaller platform widths are used (depending on car type, access and individual driving behaviour and capability).For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing manoeuvring radius).
10
11
11 11 11
11
11
10
10 10 10
10
Page 2 of 7Page 1SectionDimensionsCar data
Page 2DoorWidthdimensions
Page 3WidthdimensionsApproachFree spaces
Page 4FunctionLoad plan
Page 5Technicaldata
Page 6Electrical To be perfor-med by thecustomer
Page 7Description
TrendVario 4300 | Code number 585.29.210-013 | Version 05.2017
Garages with roll doors | Widths dimensionsRoll door behind columns Columns per each grid unit
175175200200230
GT325/345/365/405380/435350/375380/405/435380/405/420/435
Height210220210220220
H1
240 390/405/415/435/445/455 230
230240250260
250260270280
270 290
B5230240250260270
B6Usable platform width250260270280290
RB43004300430043004300
Type
4300
20
RB RB RB
20 20B5 B6No. of grids x RB + 20
10
Carriageway in accordancewith local regulations
Heigh
tGT
H130
0
15
550 (570)30
H2
30 35
Longitudinal free space
10 RB
45
Entrance level
Longitudinalfree space
20
RBRBRB
Emptyspace
Approach
Maximumdescendingslope 3 %
Maximumascendingslope 5 %
According to the BGR 232, an inspection book is required for the commercial use of a gate with electric drive. Prior to commissioning,and then once a year, the gate has to be inspected by an expert and the findings entered in the inspection book. The inspection hasto be carried out independent of any maintenance work.For parking boxes on the edges and boxes with intermediate walls we recommend our maximum platform width of 270 cm.Please consider adjoining grids. Problems may occur if smaller platform widths are used (depending on car type, access and individual driving behaviour and capability).For larger limousines and SUV wider driveways are necessary (in particular on the boxes on the sides due to the missing manoeuvring radius).
RB = Grid unit width must strictly conform to dimensions quoted!H2 for heigth >360 = 20 / H2 for heigth ≥380 = 75
The illustrated maximum approach angles must not be exceeded. Incorrect approach angles will cause serious maneouvring & positioning problems on the parking system for which the local agency of KLAUS Multiparkingaccepts no responsibility.
RB = Grid unit width must strictly conform to dimensions quoted!
12
12
13
14
14
Page 3 of 7Page 1SectionDimensionsCar data
Page 2DoorWidthdimensions
Page 3WidthdimensionsApproachFree spaces
Page 4FunctionLoad plan
Page 5Technicaldata
Page 6Electrical To be perfor-med by thecustomer
Page 7Description
13
TrendVario 4300 | Code number 585.29.210-013 | Version 05.2017
Load plan
230240250260
250260270280
260270280290
270 290 300
Usable platform width RB RB1135140145150155
RB2 Platform load2000 kg2600 kg
F1±5±5
F2±2,5±2,5
F3±14,5±14,5
F4+70+80
F5±29±29
F6±0,2±0,2
F7±2,5±2,5
F8+25+35
F9+50+70
The system is dowelled to floor and walls. The drilling depth in the floor is approx. 15 cm. The drilling depth in the walls is approx. 12 cm.Floor and walls are to be made of concrete (grade of concrete min. C20/25)!The dimensions for the points of support are rounded values. If the exact position is required, please contact KLAUS Multiparking.
RB = Grid unit width must strictly conform to dimensions quoted!All forces in kN
15 16
15
16
Page 4 of 7
Function with standard numbering and identification of parking levels
UF
LF
GF Entra
nce
level
631
74
852
631
74 8
52
631
74
852
e.g. for parking space No. 8:Check first that all doors are closed, then select No. 8 on operating panel.
For driving the vehicle off platformNo. 8 the ground floor parkingplatforms are shifted to the left.
The empty space is now below the vehiclewhich shall be driven off the platform. Theplatform No. 8 will be lifted.
The vehicle on platform No. 8can now be driven off the platform.
Page 1SectionDimensionsCar data
Page 2DoorWidthdimensions
Page 3WidthdimensionsApproachFree spaces
Page 4FunctionLoad plan
Page 5Technicaldata
Page 6Electrical To be perfor-med by thecustomer
Page 7Description
F8 F9F3 F4 F5
F1 F1 F1F2 F2 F2
F8 F9F3 F4 F5F8 F9F3 F4 F5
F1
F1
F6
F7
F1
F1
F6
F7F1 F2
F8 F9F3 F4 F5
F1
F1
F6
F7
F1
F1
F6
F7
170
135
185
H3
H4
195
185
H3
160
H4
225
190
185
H3
H4
6 6550 (570) 6 6
550 (570) 6 6550 (570)
175
Heigh
t
200
Heigh
t
230
Heigh
t
235
200
185
H3
H4
6 6550 (570)
240
Heigh
t
Type 4300-175Car height
GF150170190170205190205
Height325345365365380405435
130150170150185170185
H3245265285265300285300
H4
Type 4300-200Car height
GF175175205205205
Height350375380405435
155155185185185
H3270270300300300
H4
Type 4300-230Car height
GF205205205205
Height380405420435
185185185185
H3300300300300
H4
Type 4300-240Car height
GF215215215215215215
Height390405415435445455
195195195195195195
H3310310310310310310
H4
4300-175 4300-200 4300-230 4300-240
Load plan – top view
RB1
RB2 RB RB RB RB
RB RB RB RB1
F3 F4
F1F2 F1F2 F1F2 F1F2 F1F2 F2
F5 F3F4 F5 F4 F5 F4 F5 F4
F8 F9 F9 F9 F9 F8
F6 F7 F6 F7F6 F7F6 F7F6 F7 F6 F7
TrendVario 4300 | Code number 585.29.210-013 | Version 05.2017
Technical data
– wall recess plans– maintenance offer/contract– declaration of conformity– test sheet on airborne and slid-borne sound
Available documents
By default, the system can only be used for a fixed number ofusers.If different users use the system (e.g. short-time parkers in officebuildings or hotels) the Multiparking system needs to be adjusted. If required, would you please contact us.
Field of application
Environmental conditions for the area of multiparking systems:Temperature range –10 to +40° C. Relative humidity 50% at amaximum outside temperature of +40° C.If lifting or lowering times are specified, they refer to an environmental temperature of +10° C and with the system set up directly next to the hydraulic unit. At lower temperatures or with longer hydraulic lines, these times increase.
Environmental conditions
See separate sheet regarding corrosion protection.Corrosion protection
According to DIN 4109 (Sound insulation in buildings), para. 4,annotation 4, KLAUS Multiparkers are part of the building services(garage systems).
Normal sound insulation:DIN 4109, para. 4, Sound insulation against noises from buildingservices.Table 4 in para. 4.1 contains the permissible sound level valuesemitted from building services for personal living and working areas. According to line 2 the maximum sound level in personal living andworking areas must not exceed 30 dB (A). Noises created by users are not subject to the requirements(see table 4 , DIN 4109).The following measures are to be taken to comply with this value:– Sound protection package according to offer/order
(KLAUS Multiparking GmbH)– Minimum sound insulation of building R’w = 57 dB
(to be provided by customer)
Increased sound insulation (special agreement):Draft DIN 4109-10, Information on planning and execution,proposals for increased sound insulation.Agreement: Maximum sound level in personal living and workingareas 25 dB (A). Noises created by users are not subject to therequirements (see table 4, DIN 4109).The following measures are to be taken to comply with this value:– Sound protection package according to offer/order
(KLAUS Multiparking GmbH)– Minimum sound insulation of building R’w = 62 dB
(to be provided by customer)
Note: User noises are noises created by individual users in ourMultiparking systems. These can be noises from accessing theplatforms, slamming of vehicle doors, motor and brake noises.
Sound insulation
In accordance with BGR 232 commercially used power-drivendoors must be subjected to annual inspections. We urgently recommend concluding a maintenance agreement that includes this service for the entire system.
Electrically driven doors
Standard numbering of the parking spaces:Numbering
Initial position: lower floor platform No. 2 at entrance level (covering of pit; safety regulation).Different numbering is only possible at extra cost Please take note of the following specifications:– In general, the empty space must be arranged to the left. – The numbers must be provided 8 – 10 weeks before the
delivery date.
1 3 6
4 7
2 5 8
9
10
11
Emptyspace
6
7
8
Entrance level
According to LBO and GaVo (garage regulations) the Multiparking systems are subject to approval. We will provide the required building application documents.
Building application documents
To avoid damages resulting from corrosion, make sure to follow our cleaning and care instructions and to provide good ventilation of your garage.
Care
Page 5 of 7Page 1SectionDimensionsCar data
Page 2DoorWidthdimensions
Page 3WidthdimensionsApproachFree spaces
Page 4FunctionLoad plan
Page 5Technicaldata
Page 6Electrical To be perfor-med by thecustomer
Page 7Description
The systems on offer comply with DIN EN 14010 and EC Machine Directive 2006/42/EC. Furthermore, this system underwent voluntary conformity testing by TÜV SÜD.
CE Certification
TrendVario 4300 | Code number 585.29.210-013 | Version 05.2017
To be performed by the customer
Any constraints that may be necessary according to DIN EN ISO13857 in order to provide protection for the park pits for pathways directly in front, next to or behind the unit. This is also valid during construction.
Safety fences
Consecutive numbering of parking spaces.Numbering of parking spaces
Any required lighting, ventilation, fire extinguishing and fire alarmsystems as well as clarification and compliance with the relevantregulatory requirements.
Building services
Any necessary wall cuttings.Wall cuttings
For the middle area of the pit we recommend a drainage channel,which you connect to a floor drain system or sump (50 x 50 x 20 cm).The drainage channel may be inclined to the side, however not thepit floor itself (longitudinal incline is available). In the interests ofenvironmental protection we recommend painting the pit floor. Oiland petrol separators must be provided according to the statutoryprovisions when connecting to the public sewage system!
Drainage
If due to structural conditions strip footings must be effected, thecustomer shall provide an accessible platform reaching to the topof the said strip footings to enable and facilitate themounting work.
Strip footings
Suitable electrical supply to the control box must be provided by the customer during installation. The functionality can be monitoredon site by our fitters together with the electrician. If this cannot bedone during installation for some reason for which the customer isresponsible, the customer must commission an electrician at theirown expense and risk. In accordance with DIN EN 60204 (Safety of Machinery. ElectricalEquipment), grounding of the steel structure is necessary, providedby the customer (distance between grounding max. 10 m).
Electrical supply to the control box / Foundation earth connector
– Costs for final technical approval by an authorized body
If the following are not included in the quotation, they will alsohave to be provided / paid for by the customer:
Door shields that may be necessary. If desired, they can be orderedfrom KLAUS Multiparking for an additional charge.
Door shields
The lintel height H2 (see page 2) is absolutely necessary. With differing heights, additional fixings are required for extra charge.
Door suspension
Page 6 of 7Page 1SectionDimensionsCar data
Page 2DoorWidthdimensions
Page 3WidthdimensionsApproachFree spaces
Page 4FunctionLoad plan
Page 5Technicaldata
Page 6Electrical To be perfor-med by thecustomer
Page 7Description
Electrical data
The control box must be accessible at all times from outside!Dimensions approx. 100 x 100 x 30 cm.Cutting through of wall from control box to parking system (contact the local agency of KLAUS Multiparking for clarification).
Control boxSuitable electrical supply min. 5 x 2,5 mm2 (3 PH+N+PE) to controlbox with mains fuse 3 x 16 A slow or over-current cut-out 3 x 16 A trigger characteristic K or C. DIN/VDE and local regulationsmust be taken into consideration.Suitable electrical supply to the control box must be provided by thecustomer during installation. The functionality can be monitored onsite by our fitters together with the electrician. If this cannot be doneduring installation for some reason for which the customer isresponsible, the customer must commission an electrician at theirown expense and risk. In accordance with DIN EN 60204 (Safety of Machinery. ElectricalEquipment), grounding of the steel structure is necessary, providedby the customer (distance between grounding max. 10 m).
Electrical supply to the control box / Foundation earth connector
Cutting through
Parking system fully visiblefrom control box
Easy-to-survey positioning (e.g. on column).Protection against unauthorized use.May also be recessed in wall if required.
Operating device
Description
Multiparking system providing independent parking spaces for cars,one on top of the other and side by side.Dimensions are in accordance with the underlying dimensions ofparking pit, height and width.The parking bays are accessed horizontally (installation deviation ± 1%).Along the complete width of the parking automat an approach lane(driving lane in accordance with local regulations) must be available.Parking spaces are arranged on three different levels, one level on top of the other.The platforms of both the lower floor (LF) and upper floor (UF) aremoved vertically, the platforms of the ground floor (GF) horizontally. At approach level (GF) there is always one parking space less available. This vacant space is used for shifting the ground floor (GF)parking spaces sideways, thus enabling an upper floor (UF) parkingspace or lower floor (LF) parking space to be lowered or lifted to ap-proach level. Consequently, a unit of five parking spaces (2 on theupper floor, 1 on the ground floor, 2 on the lower floor) is the smallestunit available for this parking system.The TrendVario 4300 allows parking of passenger cars and stationwagons.For safety reasons the platforms can only be moved behind locked doors.All necessary safety devices are installed. This consists mainly ofa chain monitoring system, locking lever for the upper and lower platforms and locked doors. The doors can only be opened if the selected parking space has reached the park position and all openings are secured.
General description:– Seriated supports– Steel pillars with sliding platform supports– Cross and longitudinal members– running rails for the transversely movable ground floor
(GF) platforms
A steel framework mounted inside the pit, consisting of:
– Side members– Cross members– Platform base sections – 1 wheel stop (on the right per parking space) – Screws, small parts, etc.
Platforms consisting of:
– Hydraulic cylinder with solenoid valve– Chain wheels– Chains – Limit switches – The platforms are suspended on four points and guided along
the supports using plastic sliding bearings.
Lifting device for upper floor (UF) and lower floor (LF) platforms:
– Gear motor with chain wheel– Chains– Running and guide rollers (low-noise)– Power supply via cable chain
Drive unit of transversely movable platforms on the ground floor (GF):
TrendVario 4300 | Code number 585.29.210-013 | Version 05.2017
Description
SizeSliding door, dimensions: approx. 2500 mm x 2000 mm (width x height).
Frame– Frame construction with vertical centre stay bar made from
extruded aluminium profiles (anodized, layer thickness approx 20 μm).
– To open the doors a recessed grip is integrated in the aluminium profile.
– A rubber lip is used for the finishing of the closing edge to thebuilding.
Standard door panelPerforated steel plate– Thickness 1mm, RV 5/8, galvanized, layer thickness: approx. 20 μm– Ventilation cross-section of the panel approx. 40%– Not suitable for outdoor garages
Alternative door panelPerforated aluminium plate– Thickness 2mm, RV 5/8 E6/EV1, anodized, layer thickness:
approx. 20 μm– Ventilation cross-section of the panel approx. 40%Beaded steel plate– Thickness 1mm, galvanized, layer thickness: approx. 20 μm.– additional power coating, layer thickness: approx. 25 μm on the
outside and approx. 12 μm on the inside– Colour options for the outside (building view):
RAL 1015 (light ivory), RAL 3003 (ruby),RAL 5014 (pigeon blue), RAL 6005 (moss green),RAL 7016 (anthracite grey), RAL 7035 (light grey),RAL 7040 (window grey), RAL 8014 (sepia),RAL 9006 (white aluminium), RAL 9016 (traffic white)
– Inside of the gates in light greyPlain aluminium sheet– Thickness 2mm, E6/EV1, anodized, layer thickness: approx. 20 μmWooden panelling– Nordic spruce in grade A– vertical tongue and groove boards– preimpregnated colourlessLaminated safety glass– Laminated safety glass made from single pane safety glass 8/4mmWire grating– Mesh size 12 x 12 mm– Mesh size 40 x 40 mm (for manual sliding gates only)
Running rails– The running gear of each doors consists of 2 twin-pair rolling
gadgets, adjustable in height– The running rails of the doors are fixed to brackets or the
concrete lintel, or on a building-specific door suspensionusing ceiling fittings
– The guide consists of 2 plastic rollers mounted to a baseplate, which is dowelled to the floor
– Running rails, ceiling fittings and guide roller base plateare hot-dip galvanized
Door actuationStandard:– Manually, i.e. the door is opened and closed by handAlternatively:– Electric drive via electric motor mounted to the rail system
at the turning point of the sliding doors. The drive pinionengages into the chain mounted to the door.
For safety reasons the movement of the platforms is always madebehind locked doors. Position sensing, i.e. “door open” and“door closed” is effected by electric signalers.
Separation (if necessary):– Upon request
Please note:Door panels (on the side, cover for running rails, etc.) and doorsuspensions are not included in the standard version but can bedelivered against surcharge as special equipment.
Sliding doors:
SizeDimensions modified based on width and height measurements.
Shutter box– multipart extruded aluminium box 20°– lacquered type
Guide rails– extruded aluminium guide rails with brush insert– lacquered type
Gate type– aluminium gate type, extruded– end rod with electronic safety strip– lacquered type
Colour optionsShutter box, guide rails and gate type are avialabel withthe following colour options:– RAL 9016 (traffic white)– RAL 9006 (white aluminium)– RAL 7016 (anthracite grey)
Door actuationPowered electrically by means of tube motor in the shaft.For safety reasons the movement of the platforms is always made behind locked doors. Position sensing, i.e. “door open” and “door closed” is effected by electric signalers.
Roller doors:
We reserve the right to change this specification without further noticeKLAUS Multiparking reserves the right in the course of technical progress to use newer or other technologies, systems, processes, procedures or standards in the fulfillment of their obligations other than those originally offered provided the customer derives no disadvantage from their so doing.
Page 7 of 7Page 1SectionDimensionsCar data
Page 2DoorWidthdimensions
Page 3WidthdimensionsApproachFree spaces
Page 4FunctionLoad plan
Page 5Technicaldata
Page 6Electrical To be perfor-med by thecustomer
Page 7Description
– Central control panel (operating device) used to select the desiredparking space
– With series installation, the doors are opened manually If desired, this can also be done using electric motors
– Electric wiring is made from the electric cabinet by the manufacturer
Control system:
– Hydraulic power unit (low-noise, installed onto a console with arubber-bonded-to-metal mounting)
– Hydraulic oil reservoir– Oil filling– Internal geared wheel pump– Pump holder– Clutch– 3-phase-AC-motor (3.0 kW, 230/400 V, 50 Hz)– Motor circuit breaker– Test manometer– Pressure relief valve– Hydraulic hoses (which reduce noise transmission onto the
hydraulic pipe
Hydraulic unit consisting of: