presenter ho-lin chang. introduction design implementation evaluation conclusion and future work 2

44
Presenter Ho-lin Chang

Upload: eustacia-sanders

Post on 30-Dec-2015

222 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

Presenter Ho-lin Chang

Page 2: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Introduction• Design• Implementation• Evaluation• Conclusion and future Work

2

Page 3: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Indoor location-based service

3

Healthcare Security Warehouse

Page 4: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Existed indoor localization technique– UWB– Ultrasound– WiFi

4

UWB

WiFi

Ultrasound

Page 5: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• UWB (Ubisense)– Accuracy: 10 ~ 20 cm– Time difference of arrival– Expensive specialized

hardware (10,000 USD)

5

Page 6: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Ultrasonic (Cricket)– Accuracy: 10 ~ 20 cm– Short range– Non-line of sight problem

6

Page 7: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• WiFi (Ekahau, RADAR)– RSS fingerprinting– Accuracy: 3 ~ 5m– Low cost– Offline training

7

Page 8: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

Technologies Accuracy Properties

UWB 15 cm • Specialized hardware

Ultrasound 15 cm• Short range• Non-line of sight problem

WiFi 300~500 cm • Offline training

? cm range• Low cost• Radio• No offline training

8

Page 9: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Develop a novel localization system – Spinning beacon (RF)– Indoor environment– Sub-meter accuracy• 50% < 39 cm• 90% < 70 cm

– Low cost• Low cost motes (100 USD)• Rotation motor

9

Page 10: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

10

Page 11: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

S

S

S

XX

RR

XX

11

The location of XThe location of X

Page 12: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

X

S v

f vproject

12

Page 13: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

X

Δf = 0 HzΔf = 0 HzΔf = 30 HzΔf = -30 Hz

timeΔf (t) = ?30Hz

0Hz

0Hz

-30Hz

vS

13

Page 14: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

v(t)

S

X

α

x

y

dr

S : (r cosθ, r sinθ)v(t) = (-ωr sinθ, ωr

cosθ)

θ(t) = ωt+φ

X : (d cosα, d sinα)

14

Page 15: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

S

v(t) X

αx

y

RRβ

15

Page 16: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

16

Page 17: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

S

S

S

XX

RR

XX

17

The location of X

Page 18: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

18

500 Hz

A 900 MHz

900 MHz + 500 HzBThe location of X

Page 19: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

19

The location of X

Page 20: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Hardware–Crossbow MICA2

–Rotational motor

• Software– TinyOS 1.x–C/C++

20

Page 21: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Testbed– 國發所地下室停車場– Three spinning beacons– 30 sample points (2m grid)

• 10 position samples (300 samples)• 3 angles (900 angles)

• Evaluation metrics– Positional error– Angular error

• Parameter Tuning

21

Page 22: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

50% < 3 degrees

90% < 10 degrees

50% < 3 degrees

90% < 10 degrees

22

Page 23: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

50% < 3 degrees

90% < 10 degrees

50% < 39 cm

90% < 70 cm

23

Page 24: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Data collection time• Rotational velocity

• Interference frequency

• Angulation filtering threshold– Minimum distance as a quality indicator

24

Page 25: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

25

Page 26: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

26

Page 27: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

Lower frequency estimation precision

27

Page 28: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

28

Page 29: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Track fast moving targets• Rotational device

29

Page 30: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Develop a novel localization system– Spinning beacon– Indoor environment– Low cost– Sub-meter accuracy• 39cm / 70cm

30

Page 31: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Reduce the localization latency–Reduce the routing time• Distributed version• Data compression

• Track the fast moving targets

31

Page 32: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2
Page 33: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2
Page 34: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

34

Page 35: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

r/d

0.10.30.5

0

35

Page 36: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

36

Page 37: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

37

k

Page 38: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

A

B

Xv

fA

fB

|fA-fB||fA + ΔfX - fB|

Page 39: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

R

S A

S

S

39

Page 40: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

40

Time

Signal strength

Page 41: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

• Each infrastructure perceives different Doppler shift.

• Localize the target by different Doppler shifts

Xv

41

I

I

I

II

I

Page 42: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

Maximum Doppler shiftf : 900 MHz ω : 2.5 round/secr : 30 cm ~ 50 cm

42

Page 43: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

0.3 ~ 1.5 sec 8 ~ 10 sec1st Doppler angulation

2nd Doppler angulation3rd Doppler angulation

Localization

43

Page 44: Presenter Ho-lin Chang. Introduction Design Implementation Evaluation Conclusion and future Work 2

v(t)

S

X

α

x

y

dr

S : (r cosθ, r sinθ, 0)v(t) = (-ωr sinθ, ωr cosθ, 0)

θ(t) = ωt+φ

X : (d cosα, d sinα, h)

44