Technical Document

Version 0.0

November, 2008

www.cermate.com

PLC Connection Guide

TN526D

Communication settings between LUST ServoC/CDE and PanelMaster

◎Revision Record

Revision Date Content Owner

TND526-E0

Page 2 of 9 www.cermate.com

Preface

This tech note introduces how to connect LUST ServoC controller with PanelMaster

HMI.

X5 --- CANopen / RS485

X6 --- USB Port

TND526-E0

Page 3 of 9 www.cermate.com

(1) PLC Parameter setting:

(a) Please install the program software “LTi DriveManager” to your PC and then plug-in the USB Cable into LUST controller.

(b) When the USB cable link with the LUST controller, the software will install the USB driver automatically.

(c) If the USB driver was installed successfully, you will link with the LUST controller via USB cable directly.

TND526-E0

Page 4 of 9 www.cermate.com

(d) When you link with the LUST controller, please set the User Level to: Develop Engineer (6). (Initial Password is “678”)

(e) At this moment, please enter “Extras --- Parameter Editor” and set the RS485 value as “1” to enable the RS485 communication.

TND526-E0

Page 5 of 9 www.cermate.com

NOTE:

If you enable the RS485 communication, the USB port will not be linking with

the LUST controller at the same time.

Connection Cable Diagram:

HMI Side PLC Cable Side

COM1 9-PIN Male

PV-Series

LUST ServoC (X5)

DB9 male (RS485)

TXD + 1 5 DATA+

TXD - 6 4 DATA-

GND 5 3 GND

9 DC +24V

6 DC 0V

TND526-E0

Page 6 of 9 www.cermate.com

HMI COM2 LUST ServoC

HMI Side PLC Cable Side

COM1 9-PIN Male

LUST ServoC (X5)

DB9 male (RS485)

TXD + 1 5 DATA+

TXD - 4 4 DATA-

GND 5 3 GND

9 DC +24V

6 DC 0V

NOTE:

If you wish to use the RS485 to link with the HMI, the X5 connector meeds to

poovides DC24V power from Pin9 and Pin6.

TND526-E0

Page 7 of 9 www.cermate.com

(2) HMI setting:

Select 【Direct Link [COM] 】&【Device/Server: Lust Antriebstechnik GmbH→ LustBus ServoC/CDE

Series】

Set the Parameter as “57600; 7, Even, 1” and PLC Address=“1”.

TND526-E0

Page 8 of 9 www.cermate.com

(3) PLC Memory Address

Bit Devices:

Word Devices:

~Thank You~

TND526-E0

Page 9 of 9 www.cermate.com

Technical Support Information

中國大陸 QQ專線 : 800014850 www.panelmaster.com.cn / www.cermate.com

資料下載專區 ftp:://mail.cermate.com + User name + Password (欲加入會員需要申請)

合作貼牌聯絡專線: China: 0910011916 / 86-13823788405 [email protected] Taiwan: 886-910011915 [email protected]

Worldwide: 886-910011914 [email protected]

Cermate Technologies (Shanghai) Inc. 屏通科技(上海)有限公司

Phone: +86-21-51758590~2 FAX : +86-21-51758589

E-mail: [email protected]

Shenzhen Cermate Technologies Inc. 屏通科技(深圳)有限公司

Phone: +86-755-83562179, FAX : +86-755-83562294

E-mail: [email protected]

Cermate Technologies Inc. (台湾) 屏通科技股份有限公司 7F-1, No. 168, Lien-Cheng Road, Chung-Ho City, Taipei, Taiwan 235 R.O.C.

Phone: 886-2-22437000 FAX : 886-2-22499933

E-mail: [email protected]