system controller · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3...

10
English SYSTEM CONTROLLER Quick Guide SPC-2010

Upload: others

Post on 23-Jul-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SYSTEM CONTROLLER · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3 axicom imo35vdc axicom imo3 5vdc audio_inaudio_out rx+ rx-tx+ tx-gnd com n.o controller

English

SYSTEM CONTROLLERQuick Guide SPC-2010

Page 2: SYSTEM CONTROLLER · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3 axicom imo35vdc axicom imo3 5vdc audio_inaudio_out rx+ rx-tx+ tx-gnd com n.o controller

2_ English

What’s IncludedUnpack the product package and place the product on the floor or a flat surface. Check if the following components are all included in the product package.

1 2 3

4 5 6

7 8 9

CLR ENT

CAM

MENU

FUNC

MODE

SEARCH FREEZE ALARM

SETUP

AUDIO REC

GROUP

E S CPWR

A/F AUXPRESET

MON PTZ/DVR

PWR Tx Rx

0

PTZ IRIS

FOCUS

ZOOMW T

Main Unit User Manual Power Adaptor 1EA

Tx1Tx2

Tx3TRx

Terminal Block 1EA

Page 3: SYSTEM CONTROLLER · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3 axicom imo35vdc axicom imo3 5vdc audio_inaudio_out rx+ rx-tx+ tx-gnd com n.o controller

English _3

english

system controller at a Glance

Front side

Item Description

a DVR Play Bar Play/Pause, Fast Forward/Fast Backward, Stop, Record

b ESC / PWR Cancels a command or turns power on/off.

c LCD Display Display the operation status and the setup menu of the system controller.

d Controller Selection Bar Used to select a camera, monitor or DVR.

e Joystick Controller

You can manipulate the Pan/Tilt operation up or down in connection with the PTZ camera or receiver unit. Turn the joystick clockwise or counter clockwise to control zooming. You can control the direction of the connected controller from the menu screen of the controller.

f Camera Operation Bar Runs Preset, Group, Auto Focus and Aux output functions.

g DVR Control Bar Executes the selected DVR’s Audio, Search, screen mode selection, Freeze and Alarm Control.

1 2 3

4 5 6

7 8 9

CLR ENT

CAM

MENU

FUNC

MODE

SEARCH FREEZE ALARM

SETUP

AUDIO REC

GROUP

E S CPWR

A/F AUXPRESET

MON PTZ/DVR

PWR Tx Rx

0

PTZ IRIS

FOCUS

ZOOMW T

a b c ed

fk hj gi

Page 4: SYSTEM CONTROLLER · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3 axicom imo35vdc axicom imo3 5vdc audio_inaudio_out rx+ rx-tx+ tx-gnd com n.o controller

4_ English

Item Description

h Camera Lens Bar

IRIS Control Iris (-: CLOSE/+: OPEN)

FOCUS Adjust the focus (-: NEAR/+: FAR)

ZOOM Zoom In/Out (W: WIDE/T: TELE)

i Others

MENU Enters PTZ and DVR menu.

FUNC Press [FUNC] button and desired function button to run.

SETUP Press a number button and press [SETUP] button to enter the settings menu.

Used in DVR mode for controlling the camera connected to the DVR.

jNumber (0-9), ENT, CLR Buttons

Number (0-9) Used to specify numeric characters for camera, monitor, DVR or Preset settings.

ENT Move to a desired item using the navigation buttons and select it.

CLR Cancel the current operation.

k Jog ShuttleJog Used to search for forward/reverse frame in DVR play mode.

Shuttle Forward/Reverse/Play/FF/REW in DVR play mode.

Page 5: SYSTEM CONTROLLER · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3 axicom imo35vdc axicom imo3 5vdc audio_inaudio_out rx+ rx-tx+ tx-gnd com n.o controller

English _5

english

rear side

Item Description

a Power DC 12V input port ( )

b RS-485/422 For RS-485/422 communication, connected to camera, DVR and other control devices.

M ` [PROGRAM] is not for user’s accessing.

DC IN 12VTx1 Tx2 Tx3 TRx

PROGRAM

a b

Page 6: SYSTEM CONTROLLER · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3 axicom imo35vdc axicom imo3 5vdc audio_inaudio_out rx+ rx-tx+ tx-gnd com n.o controller

6_ English

to connect a rs-485/422 devIceWith the system controller, you can control the PTZ camera or DVR that supports RS-485/422 communication protocols.1. Connect the rear Tx1 with RS-485 port of the PTZ camera or DVR.2. According to the external device connected, select RS-485 (Half Duplex) or RS-422 (Full Duplex)

connection.

M ` For RS-485/422 communications, pay special attention to the polarity (+/-).

` Use the provided terminal block in the product package.

` Check if the RS-485/422 device is compatible with SPC-2010.

connecting rs-485/422 signal Wires• RS-485 Communications • RS-422 Communications

RXD+ TRx+RXD– TRx–

Camera ControllerRXD+

TXD+

Tx1+

TRx+

RXD–

TXD–

Tx1–

TRx–

Camera Controller

` You may use the Tx2 or Tx3 terminal instead of Tx1.

Tx1 Tx2 Tx3 TRx

Tx1 Tx2 Tx3 TRx

DC IN 12VTx1 Tx2 Tx3 TRx

PROGRAM

Page 7: SYSTEM CONTROLLER · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3 axicom imo35vdc axicom imo3 5vdc audio_inaudio_out rx+ rx-tx+ tx-gnd com n.o controller

English _7

english

connecting the PtZ cameraBy connecting RS-485 port on the rear of the PTZ camera with Tx of SPC-2010, you can control the camera.

M ` Depending on the camera, the polarity may differ. For more information, refer to the user manual of the PTZ camera.

For the half duplex system - Connect Rx (+) of RS-485 port of the PTZ camera with TRx (+) of SPC-2010. - Connect Rx (–) of RS-485 port of the PTZ camera with TRx (–) of SPC-2010.

` If connecting a PTZ camera without using DVR device, you can connect to Tx1, Tx2 or Tx3 instead of TRx.

Tx1 Tx2 Tx3 TRx

DC IN 12VTx1 Tx2 Tx3 TRx

PROGRAMTx1 Tx2 Tx3 TRx IN1

IN2

GN

D IN

3 IN

4 G

ND

1C0M

1.N

0 1

.NC

2C0M

2.N

0 2

.NC

2N.C

2N.0

COM2

1N.C

1N.0

COM1

GND

IN4IN3

GND

IN2

IN1

Alarm

AXIC

OM

IMO

35V

DC

AXIC

OM

IMO

35V

DC

AXIC

OM

IMO

35V

DC

Video Out

AUDIO_OUTAUDIO_IN

RX+

RX-

TX+

TX-

GND

COM

N.O

ControllerAux

PowerAC 22~26V

Alarm2 ONAlarm1 ON

D+ D- TXD+ TXD- GND A.COM A.NO

AXIC

OM

IMO

35V

DC

AXIC

OM

IMO

35V

DC

AXIC

OM

IMO

35V

DC

AUDIO_OUTAUDIO_IN

RX+

RX-

TX+

TX-

GND

COM

N.O

ControllerAux

AC 22~26V

D+ D- TXD+ TXD- GND A.COM A.NO

Page 8: SYSTEM CONTROLLER · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3 axicom imo35vdc axicom imo3 5vdc audio_inaudio_out rx+ rx-tx+ tx-gnd com n.o controller

8_ English

For the full duplex system - Connect Rx (+) of RS-485 port of the PTZ camera with Tx1 (+) of SPC-2010. - Connect Rx (–) of RS-485 port of the PTZ camera with Tx1 (–) of SPC-2010. - Connect Tx (+) of RS-485 port of the PTZ camera with TRx (+) of SPC-2010. - Connect Tx (–) of RS-485 port of the PTZ camera with TRx (–) of SPC-2010.

connecting srd-16XX/8XX series dvrConnect between DVR and SPC-2010 using RS-485 port on the rear of the DVR.

For the half duplex system - Connect Tx (+) of RS-485 port of the DVR with TRx (+) of SPC-2010. - Connect Tx (–) of RS-485 port of the DVR with TRx (–) of SPC-2010.

Tx1 Tx2 Tx3 TRx

DC IN 12VTx1 Tx2 Tx3 TRx

PROGRAM

Tx1 Tx2 Tx3 TRx IN1

IN2

GND

IN3

IN4

GND

1C

0M

1.N0

1.NC

2C

0M

2.N0

2.NC

2N.C

2N.0

COM2

1N.C

1N.0

COM1

GND

IN4IN3

GND

IN2

IN1

Alarm

AXIC

OM

IMO

35V

DC

AXIC

OM

IMO

35V

DC

AXIC

OM

IMO

35V

DC

Video Out

AUDIO_OUTAUDIO_IN

RX+

RX-

TX+

TX-

GND

COM

N.O

ControllerAux

PowerAC 22~26V

Alarm2 ONAlarm1 ON

D+ D- TXD+ TXD- GND A.COM A.NO

AXIC

OM

IMO

35V

DC

AXIC

OM

IMO

35V

DC

AXIC

OM

IMO

35V

DC

AUDIO_OUTAUDIO_IN

RX+

RX-

TX+

TX-

GND

COM

N.O

ControllerAux

AC 22~26V

D+ D- TXD+ TXD- GND A.COM A.NO

Tx1 Tx2 Tx3 TRx

CH 1

CH 3

CH 2

CH 4

AUDIO IN

AUDIO OUT

VGA

CONSOLE

SERIAL

NETWORK

USB

VID

EO IN

LOO

P O

UT

SPOT

ALARM INALARM OUT

INAC 100-240~

DC IN 12VTx1 Tx2 Tx3 TRx

PROGRAM

Tx1 Tx2 Tx3 TRx

CH 2

CH 4

AUDIO IN

AUDIO OUT

VIDEOOUT

VGA

CONSOLE

SERIAL

NETWORK

USB

VID

EO IN

LOO

P O

UT

ALARM OUT

Page 9: SYSTEM CONTROLLER · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3 axicom imo35vdc axicom imo3 5vdc audio_inaudio_out rx+ rx-tx+ tx-gnd com n.o controller

English _9

english

For the full duplex system - Connect Tx (+) of RS-485 port of the DVR with TRx (+) of SPC-2010. - Connect Tx (–) of RS-485 port of the DVR with TRx (–) of SPC-2010. - Connect Rx (+) of RS-485 port of the DVR with Tx1 (+) of SPC-2010. - Connect Rx (–) of RS-485 port of the DVR with Tx1 (–) of SPC-2010.

connecting srd-4XX dvrConnect RS-485 port on the rear of SRD-4XX with SPC-2010.

For the half duplex system - Connect Tx (+) of SRD-4XX with TRx (+) of SPC-2010. - Connect Tx (–) of SRD-4XX with TRx (–) of SPC-2010.

M ` Not supported by SRD-480D.

Tx1 Tx2 Tx3 TRx

CH 1

CH 3

CH 2

CH 4

AUDIO IN

AUDIO OUT

VGA

CONSOLE

SERIAL

NETWORK

USB

VID

EO IN

LOO

P O

UT

SPOT

ALARM INALARM OUT

INAC 100-240~

DC IN 12VTx1 Tx2 Tx3 TRx

PROGRAM

Tx1 Tx2 Tx3 TRx

CH 2

CH 4

AUDIO IN

AUDIO OUT

VIDEOOUT

VGA

CONSOLE

SERIAL

NETWORK

USB

VID

EO IN

LOO

P O

UT

ALARM OUT

Tx1 Tx2 Tx3 TRx

CH 1

CH 3

CH 2

CH 4

AUDIO IN

AUDIO OUT

VGA

CONSOLE

SERIAL

NETWORK

USB

VID

EO IN

LOO

P O

UT

SPOT

ALARM INALARM OUT

INAC 100-240~

DC IN 12VTx1 Tx2 Tx3 TRx

PROGRAM

Tx1 Tx2 Tx3 TRx

CH 2

CH 4

AUDIO IN

AUDIO OUT

VIDEOOUT

VGA

CONSOLE

SERIAL

NETWORK

USB

VID

EO IN

LOO

P O

UT

ALARM OUT

Page 10: SYSTEM CONTROLLER · 2015-10-21 · alarm1 on alarm2 on d+ d- txd+ txd-gnd a.com a.no axicom imo3 axicom imo35vdc axicom imo3 5vdc audio_inaudio_out rx+ rx-tx+ tx-gnd com n.o controller

SALES NETWORKSAMSUNG TECHWIN CO., LTD.Samsungtechwin R&D Center, 701, Sampyeong-dong, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea, 463-400 TEL : +82-70-7147-8740~60 FAX : +82-31-8018-3745

SAMSUNG TECHWIN AMERICA Inc.100 Challenger Rd. Suite 700 Ridgefield Park, NJ 07660 Toll Free : +1-877-213-1222 Direct : +1-201-325-6920 Fax : +1-201-373-0124www.samsungcctvusa.com

SAMSUNG TECHWIN EUROPE LTD.Samsung House, 1000 Hillswood Drive, Hillswood Business Park Chertsey, Surrey, UNITED KINGDOM KT16 OPSTEL : +44-1932-45-5300 FAX : +44-1932-45-5325

www.samsungtechwin.comwww.samsungsecurity.com