Page 1: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

Next Generation Side Stream Particle Precipitator

Page 2: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

❖ Side-Stream Particle Precipitator ( NOT a traditional media filter )

❖ Continuous Micro-Cleansing System Enhances Chemical Water Treatment

(We do not replace chemical program)

❖ Removes up to 98-99% of all suspended particles down to one micron (with no media or backwash)

Page 3: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 4: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

❖ Cooling Towers are necessary to remove heat from recirculating water.

❖ However, cooling towers also take in huge amounts of particulates, which adds to the cost of operation.

❖ A 1,000-ton cooling tower ingests 3,000 lbs of dirt, silt, sand, bugs, pollen and vegetation (ASHRAE Standard)

❖ ElectroCell Systems remove 98-99% of TSS down to one micron

Page 5: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

The more efficient equipment operates, the less energy and water consumption, resulting in substantial savings.

12-15% energy savings, chillers20-25% savings, make-up water

CLEANER GREENER

Page 6: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 7: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

• Return on investment averages 24-30 months!• Increased Life Cycles on equipment• Reduced maintenance, repair and service.• Minimal involvement by facility personnel.

Page 8: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

Clients and References• Johnson & Johnson Headquarters New Brunswick, NJ

• Morgan Stanley (Data Center) – New York City

• Wind Creek Hospitality (Casino/Hotel) – 2 locations

• PECO, Philadelphia Electric Company 11 Philadelphia locations

Two filters on 8,500-ton cooling system with VFDs and 10hp pumps

4200-ton Chiller System

• Bristol Myers Squibb, New Jersey

• Southern Company (Alabama Power)

• PPL (PA Power & Light) Allentown, PA

• The New York Botanical Gardens, Bronx, NY

Page 9: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

Fouling Factors

• TSS: Total Suspended Solids Cooling Tower Particles: Dirt, Pollen, Bugs

• TDS: Total Dissolved Solids Scale - Calcium Magnesium Carbonate

• BIO: Biological Slime (legionella)

Page 10: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

TSS: Total Suspended Solids

• Cooling Tower Particles – Dirt - pollen - bugs - airborne particles

• A 1000-ton tower will collect over 3000 pounds of solids in one year.

Page 11: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 12: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 13: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

TDS: Total Dissolved Solids• As a cooling tower evaporates condenser

water, mineral salts are left behind.

• Minerals concentrate and are discharged from the open loop by means of a conductivity meter and bleed valve.

• Make-up water is piped to the cooling towers to replace evaporation (75%) and bleed (25%) water loss.

Page 14: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

ElectroCell offers a fully automated side-stream particle precipitator to remove suspended particles, all without media and the associated backwash water use and maintenance normally required in traditional systems.

Page 15: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

User-Friendly BACnet Automation System

Typical Series

• Fully automated system• Alarm and trending• Graphic controls• Flow totalizing• Remote communications• Can be integrated with existing building automation system – BACnet, LON and Modbus

Page 16: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 17: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 18: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 19: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

ElectroCell ProductsOPEN LOOPCondenser Side Stream Modular Skid(fully automated)

CLOSED LOOPChilled Water Loop (evap)Side Stream Modular Skid

CLOSED LOOPHot Water LoopSide Stream Modular Skid

STEAM BOILERFeed Water In-lineModular Skid

Page 20: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

Merck: Five years, using ElectroCell. Photo taken from top exit tube of condenser.

Page 21: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

Without ElectroCell With ElectroCell

BOILER TUBES

Page 22: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 23: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 24: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 25: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 26: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

• System Performance Indicators (before & after)

❖ Particle measurement testing (by 3rd party lab)

❖ Kw per ton

❖ Make-up water use

• Validated increased energy efficiency 12-15%

• Documented 20-25% reduction in condenser make-up water

• Increased life cycles on equipment

• Reduced maintenance

• Reduced carbon footprint

Page 27: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water
Page 28: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

oo

o

Page 29: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

•oo

Page 30: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water

Ready to generate revenue?

Email: [email protected]: 800-949-3445Web: www.electrocellsystems.com