![Page 1: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/1.jpg)
Next Generation Side Stream Particle Precipitator
![Page 2: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/2.jpg)
❖ Side-Stream Particle Precipitator ( NOT a traditional media filter )
❖ Continuous Micro-Cleansing System Enhances Chemical Water Treatment
(We do not replace chemical program)
❖ Removes up to 98-99% of all suspended particles down to one micron (with no media or backwash)
![Page 3: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/3.jpg)
![Page 4: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/4.jpg)
❖ Cooling Towers are necessary to remove heat from recirculating water.
❖ However, cooling towers also take in huge amounts of particulates, which adds to the cost of operation.
❖ A 1,000-ton cooling tower ingests 3,000 lbs of dirt, silt, sand, bugs, pollen and vegetation (ASHRAE Standard)
❖ ElectroCell Systems remove 98-99% of TSS down to one micron
![Page 5: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/5.jpg)
The more efficient equipment operates, the less energy and water consumption, resulting in substantial savings.
12-15% energy savings, chillers20-25% savings, make-up water
CLEANER GREENER
![Page 6: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/6.jpg)
![Page 7: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/7.jpg)
• Return on investment averages 24-30 months!• Increased Life Cycles on equipment• Reduced maintenance, repair and service.• Minimal involvement by facility personnel.
![Page 8: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/8.jpg)
Clients and References• Johnson & Johnson Headquarters New Brunswick, NJ
• Morgan Stanley (Data Center) – New York City
• Wind Creek Hospitality (Casino/Hotel) – 2 locations
• PECO, Philadelphia Electric Company 11 Philadelphia locations
Two filters on 8,500-ton cooling system with VFDs and 10hp pumps
4200-ton Chiller System
• Bristol Myers Squibb, New Jersey
• Southern Company (Alabama Power)
• PPL (PA Power & Light) Allentown, PA
• The New York Botanical Gardens, Bronx, NY
![Page 9: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/9.jpg)
Fouling Factors
• TSS: Total Suspended Solids Cooling Tower Particles: Dirt, Pollen, Bugs
• TDS: Total Dissolved Solids Scale - Calcium Magnesium Carbonate
• BIO: Biological Slime (legionella)
![Page 10: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/10.jpg)
TSS: Total Suspended Solids
• Cooling Tower Particles – Dirt - pollen - bugs - airborne particles
• A 1000-ton tower will collect over 3000 pounds of solids in one year.
![Page 11: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/11.jpg)
![Page 12: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/12.jpg)
![Page 13: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/13.jpg)
TDS: Total Dissolved Solids• As a cooling tower evaporates condenser
water, mineral salts are left behind.
• Minerals concentrate and are discharged from the open loop by means of a conductivity meter and bleed valve.
• Make-up water is piped to the cooling towers to replace evaporation (75%) and bleed (25%) water loss.
![Page 14: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/14.jpg)
ElectroCell offers a fully automated side-stream particle precipitator to remove suspended particles, all without media and the associated backwash water use and maintenance normally required in traditional systems.
![Page 15: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/15.jpg)
User-Friendly BACnet Automation System
Typical Series
• Fully automated system• Alarm and trending• Graphic controls• Flow totalizing• Remote communications• Can be integrated with existing building automation system – BACnet, LON and Modbus
![Page 16: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/16.jpg)
![Page 17: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/17.jpg)
![Page 18: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/18.jpg)
![Page 19: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/19.jpg)
ElectroCell ProductsOPEN LOOPCondenser Side Stream Modular Skid(fully automated)
CLOSED LOOPChilled Water Loop (evap)Side Stream Modular Skid
CLOSED LOOPHot Water LoopSide Stream Modular Skid
STEAM BOILERFeed Water In-lineModular Skid
![Page 20: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/20.jpg)
Merck: Five years, using ElectroCell. Photo taken from top exit tube of condenser.
![Page 21: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/21.jpg)
Without ElectroCell With ElectroCell
BOILER TUBES
![Page 22: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/22.jpg)
![Page 23: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/23.jpg)
![Page 24: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/24.jpg)
![Page 25: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/25.jpg)
![Page 26: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/26.jpg)
• System Performance Indicators (before & after)
❖ Particle measurement testing (by 3rd party lab)
❖ Kw per ton
❖ Make-up water use
• Validated increased energy efficiency 12-15%
• Documented 20-25% reduction in condenser make-up water
• Increased life cycles on equipment
• Reduced maintenance
• Reduced carbon footprint
![Page 27: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/27.jpg)
![Page 28: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/28.jpg)
oo
o
![Page 29: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/29.jpg)
•
•
•
•oo
![Page 30: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/30.jpg)
Ready to generate revenue?
Email: [email protected]: 800-949-3445Web: www.electrocellsystems.com
Contact Us
![Page 31: Particle Precipitator Next Generation Side Stream MASTER PPT - 03-25-19.pdfparticle precipitator to remove suspended particles, all without media and the associated backwash water](https://reader030.vdocuments.mx/reader030/viewer/2022040323/5e689e3b5d5b757ebf3146dd/html5/thumbnails/31.jpg)
Next Generation Side Stream Particle Precipitator