on-site analytical laboratories to monitor process stability of anaerobic digestion systems

24
ON-SITE ANALYTICAL LABORATORIES T O MONITOR PROCESS STABILITY OF ANAEROBIC DIGESTION S YSTEMS From Waste to Worth: Spreading Science & Solutions Denver, Colorado ∙ April 1 – 5, 2013 Rodrigo Labatut, Ph.D. Postdoctoral Associate Biological & Environmental Engineering Cornell University

Upload: lpe-learning-center

Post on 12-Jul-2015

273 views

Category:

Education


0 download

TRANSCRIPT

Page 1: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

ON-SITE ANALYTICAL LABORATORIES TO MONITOR

PROCESS STABILITY OF ANAEROBIC DIGESTION SYSTEMS

From Waste to Worth: Spreading Science & Solutions

Denver, Colorado ∙ April 1 – 5, 2013

Rodrigo Labatut, Ph.D.Postdoctoral Associate

Biological & Environmental Engineering

Cornell University

Page 2: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Overview of anaerobic digestion (AD) in the U.S.

o 186 on-farm anaerobic digesters in the U.S. (EPA, March 2012)

Wisconsin: 28

New York: 25

Pennsylvania: 23

Page 3: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Increasing number of on-farm AD operations co-digesting manure with food wastes

Increased biomethane yields

Increased revenue by generated tipping fees

Increased project feasibility

Overview of anaerobic digestion (AD) in the U.S.

Page 4: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Performance of anaerobic digestion systems

Up to 1998, failure rates were at (Lusk, 1998):

• 63% Plug-flow reactors

• 70% Continuously-stirred tank reactors

2013

Better design and engineering numbers likely to be lower

BUT, inadequate system management and control persists…

Consequences (AD, CHP)

• Inconsistency

• Underperformance

• Short-term failure

Examples in MI, OH, NY…

Page 5: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

0

0.2

0.4

0.6

0.8

1

0%

20%

40%

60%

80%

100%

AA NHV RL NH PAT SK EM

Cap

acit

y Fa

cto

r (o

ut

of

1.0

)

On

line

Effi

cien

cy (

%)

AD systems

Online Efficiency (%) Capacity Factor

Performance of AD systems - The case of NYS

Gooch et al., 2011

88% average online efficiency

Page 6: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

0

0.2

0.4

0.6

0.8

1

0%

20%

40%

60%

80%

100%

AA NHV RL NH PAT SK EM

Cap

acit

y Fa

cto

r (o

ut

of

1.0

)

On

line

Effi

cien

cy (

%)

AD systems

Online Efficiency (%) Capacity Factor

Performance of AD systems - The case of NYS

57% average capacity factor

Gooch et al., 2011

Page 7: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Performance of AD systems - The case of NYS

Reasons for low CHP performance:

1. Decreased/unstable biogas production

2. Decreased/unstable biomethane content in biogas

3. Downtime of CHP unit due to AD system failure

4. Decreased efficiency of CHP system

5. Over-dimensioning of CHP system

6. Downtime of both AD and CHP systems due to maintenance

Page 8: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

0

20

40

60

80

100

1 3 5 7 9 11 13 15 17 19 21 23 25 27

Bio

gas

pro

du

ctio

n (f

t3/m

in)

Sampling (bi-weekly)

AA

NHV

NH

SK

EM

Responsibilities: operate, maintain, and monitor both AD and CHP systems in addition to his/her daily farm-related activities.

Nearly all active on-farm AD systems in NYS are operated by a farm worker, who usually has no previous experience or training in AD!

Performance of AD systems - The case of NYS

Gooch et al., 2011

Page 9: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Implications of low AD system performance/failure

1. Decreased energy generation

Data from US EPA (2012) from 157 operating AD systems with CHP units in the U.S.

Total of 83,738 kW electrical capacity

Page 10: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Implications of low AD system performance/failure

1. Decreased energy generation

83,738 kW electrical capacity

In a well-operated AD system with a CF = 0.9, this translates into:

• 660 GWh of total energy produced per year, an equivalent to power 57,428 U.S. households for an entire year

• $33 million in revenues, if sold to a utility company in NYS ($0.05/kWh)

BUT, with a CF = 0.57 an AD system will:

• Power 21,057 less households

• Produce $12 million less in revenue

Page 11: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

2. Co-substrates

In co-digestion operations, if AD system failure occurs:

• NO tipping fees if farm cannot receive external substrates

Tipping fees are the economic driver of most on-farm AD systems in the US!

• If contract obligates farm to receive substrates, then where to store them?

If stored in an open lagoon, odor and greenhouse gases are no contained

Implications of low AD system performance/failure

Page 12: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Operator training and AD monitoring labs in NYS

Manure Management Program at Cornell University

(NYSERDA founded project)

Goals:

1. To train and support a workforce of AD operators and technicians inNYS

2. To implement analytical labs on selected on-farm AD systems tomonitor key process parameters

3. To improve performance, detect process upsets more efficiently,and prevent system failure

Page 13: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Key process indicators to prevent digester upsets

• Retention time

• Balanced feed

• Adequate nutrients

• Right environmental conditions

2-3 days 22 days

Digesters are like cows!

Yes Yes

Yes Yes

Yes Yes

High quality /production milk

High quality /production biogas

Result

Page 14: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Parameter Determination method

pH pH meter/single-junction electrode

Temperature pH meter/thermocouple

Total alkalinity (ALK) Titration of sample with sulfuric acid 0.1 N to pH 4.0

Volatile fatty acids (VFA) Distillation of sample and titration of distillate with

sodium hydroxide 0.1 N to pH 8.3

VFA/ALK Ratio Titration method (adapted from Kapp, 1984)

Total solids (TS) Drying sample in gravity convection oven at 105oC

overnight (> 8 h)

Total volatile solids (VS) Ashing sample in muffle furnace at 550oC for 1 h

Methane content By difference of carbon dioxide content, measured

using sensidyne tubes

Total ammonia-nitrogen

(TAN)

Ion meter/ion selective electrode

AD process monitoring labs in NYS

Page 15: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Parameter Determination method

pH pH meter/single-junction electrode

Temperature pH meter/thermocouple

Total alkalinity (ALK) Titration of sample with sulfuric acid 0.1 N to pH 4.0

Volatile fatty acids (VFA) Distillation of sample and titration of distillate with

sodium hydroxide 0.1 N to pH 8.3

VFA/ALK Ratio Titration method (adapted from Kapp ,1984)

Total solids (TS) Drying sample in gravity convection oven at 105oC

overnight (> 8 h)

Total volatile solids (VS) Ashing sample in muffle furnace at 550oC for 1 h

Methane content By difference of carbon dioxide content, measured

using sensidyne tubes

Total ammonia-nitrogen

(TAN)

Ion meter/ion selective electrode

AD process monitoring labs in NYS

Page 16: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

AD process monitoring labs in NYS

Page 17: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Case study: “ Farm X AD system”

0

100

200

300

400

500

600

0

100

200

300

400

500

600

1/1/2011 2/1/2011 3/1/2011 4/1/2011 5/1/2011 6/1/2011 7/1/2011 8/1/2011 9/1/2011 10/1/2011 11/1/2011 12/1/2011 1/1/2012 2/1/2012

Bio

gas

pro

du

ctio

n (f

t3/m

in)

Po

wer

ou

tpu

t (kW

)

Biogas production

Power output

Power output

Biogas production

Page 18: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

0

200

400

600P

ow

er o

utp

ut (

kW)

CHP Power Output (kW)

6.0

6.5

7.0

7.5

8.0

8.5

9.0

pH

Effluent pH

0.0

1.0

2.0

3.0

4.0

5.0

VFA

(g/L

)

Effluent Volatile Fatty Acids (g/L)

30

40

50

60

70

VS

(g/L

)

Effluent Volatile Solids (g/L)

0

200

400

600

Bio

gas

( ft3 /

min

)

AD Biogas Production (ft3/min)

Case study: “ Farm X AD system”

Page 19: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Case study: “ Farm X AD system”

0

100

200

300

400

500

600

0

100

200

300

400

500

600

1/1/2011 2/1/2011 3/1/2011 4/1/2011 5/1/2011 6/1/2011 7/1/2011 8/1/2011 9/1/2011 10/1/2011 11/1/2011 12/1/2011 1/1/2012 2/1/2012

Bio

gas

pro

du

ctio

n (f

t3/m

in)

Po

wer

ou

tpu

t (kW

)

Biogas production

Power output

Power output

Biogas production

• Plug-flow/CSTR AD system

• Need to find the correct sampling place, after VFAs spike (hydrolysis/fermentation stages)

Page 20: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Digester operational parameters

• Organic loading rate (OLR)• Loading frequency• Temperature • Mixing frequency/speed

Substrate/feedstock characteristics

• Solids content (TS, VS)• Co-digestion ratio• Co-substrate chemical strength

Process perturbation

Digester upset

AD systemfailure

• Steady increase VFA concentrations, or VFA/ALK ratio

• Increase H2 partial pressure

• High VFA (i.e. acetate, propionate) • High H2 concentrations• Lower pH (sour digester)• Decreased biogas production• Decreased methane content• Decreased VS stabilization

• Biogas production stopped• AD system failure• CHP system down

Rel

ativ

e ti

me

Anatomy of an AD process perturbation

Page 21: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Conclusions

• Study in NYS: <60% of electric energy potential due to poor AD performance and system failure

Inadequate management and process control to blame

• Well-trained and qualified personnel to operate and monitor AD systems the process is essential

Prevent digester upsets and potential system failures

Efficient organic waste stabilization and stable biogas production

Page 22: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Conclusions

• Monitoring labs installed on selected farm-based AD systems in NYS

Monitor key process parameters and detect process upsets more efficiently

• Measured process parameters (i.e. VFA, VFA/ALK ratio) are good indicators of process upsets

• Potential to identify and correct the source of the problem before system failure occurs

Page 23: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

Acknowledgements

The authors would like to acknowledge the following farms for their willingness to participate in this project:

• Sunnyside• Roach• Sheland• Synergy• SUNY Morrisville

Special thanks to the lab operators!

• Don Kulis• Gary Mutchler• Doug Shelmadine and Sons • Randy Mastin• Ben Ballard and his students

New York State Energy Research and Development Authority (NYSERDA) for funding in support of this work

Page 24: On-Site Analytical Laboratories to Monitor Process Stability Of Anaerobic Digestion Systems

THANKS!

Contact

Rodrigo Labatut

Cornell University

e-mail: [email protected]