o&m training

Upload: palash-sarkar

Post on 04-Jun-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/13/2019 O&M Training

    1/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

    Security Level:

    www.huawei.com

    O&M training

    LMT and MML train

  • 8/13/2019 O&M Training

    2/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 2

    LMT

    LMT introduction: LMT used for RNO mainly is parameter modify, include batch

    parameter modify.

  • 8/13/2019 O&M Training

    3/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3

    LMT

    How to modify one cell RNO parameter: Right click the cell name in the tree, then select the according menu

  • 8/13/2019 O&M Training

    4/15

  • 8/13/2019 O&M Training

    5/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5

    LMT

    How to batch modify cell parameter, there are two way tobatch modify parameter in LMT.

    Using the Configure Cell parameters in Batches menu for batch

    modify.

    Using the Import Network Optimization Parameter menu forbatch modify

    The different between the above two ways is the interface.

    One using the Excel / txt file for input, One using the pop

    window for input.

  • 8/13/2019 O&M Training

    6/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6

    LMT 1.How to using file for batch modify parameter

  • 8/13/2019 O&M Training

    7/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7

    LMT 1.How to using file for batch modify parameter:

    Then in the pop window select the file which you designed.

    Pay attention to that:

    The cell Index and cell name must be right

    The row of parameter name must also be right, if you cant sure

    the name, you can first export and modify ,then input parameter How many parameter you can batch modify once is no limit, but

    be sure that the parameter value is right, carefully check it.

  • 8/13/2019 O&M Training

    8/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8

    LMT 2. How to using pop window for batch modify parameter:

    First click the menu, then following the wizard step by step

  • 8/13/2019 O&M Training

    9/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9

    LMT 2. How to using pop window for batch modify parameter:

    Then click the Modify parameter button, and batch modify the

    parameter:

    Batch modify standard value, if you

    click Batch modify button, then

    all cell value is modified according

    the Batch value

    Finally, click OK to submit all

    your modify

  • 8/13/2019 O&M Training

    10/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10

    LMT

    Disadvantage of the LMT batch modify:

    Some parameter cant be batch modify: such as GPRS support,

    EDGE support and some routing area info.

    All the TRX level parameter and Channel level parameter cant

    be batch modify

    Some interrelated parameter, such as BCCH, BSIC , if the cell is

    also other BSC external cell, using LMT cant auto synchronizeother BSC external cell info.

    We should using MML solving the above two problems,

    and only CME can solve the third problem

  • 8/13/2019 O&M Training

    11/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 11

    MML

    MML is only used for batch modify, if you only modify litterparameter, LMT is good and convenient.

    Both MML maintenance terminal and M2000 integration MML tools

    can be used for MML execute;

    Normally, we should first validate all MML command by MML

    maintenance terminal, then online for execute the MML batch

    configuration

    The different of MML LMT and M2000 is in the M2000, you can deal

    with all the BSC which M2000 managed while MML LMT only one

    BSC.

  • 8/13/2019 O&M Training

    12/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12

    MML MML LMT detail

    Help area

    Command areaSort area

    Detail area

  • 8/13/2019 O&M Training

    13/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13

    MML

    The following is the demo of MML command which modify

    one channel of the cell: test-1 to dynamic PDCH channel:

    MOD CHAN: IDXTYPE=BYNAME, CELLNAME="Test-1",

    TRXBN=1, CHNO=6, CHTYPE=DPDCH,

    GPRSCHPRI=EGPRSPRICH, TSPRIORITY=1;

    We can get all field explain by read the help area, in fact,

    If we want to change all TS6 in all cells to dynamic

    PDCH ,Its our responsibility to configure such MML

    command.

  • 8/13/2019 O&M Training

    14/15

    HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14

    MML Click the batch command come into the batch operation,

    then open the file you have already make which include theMML command

    Setting of how to

    execute the batch MML

  • 8/13/2019 O&M Training

    15/15

    Thank youwww.huawei.com