niloplast - specialized coatings · compound elongation % uni 8202/8-membrane properties mechanical...

2
COLD APPLIED BITUMINOUS COATS Group Primer and Topcoat PRODUCT NAME BITUMINOUS PRIMER APEXIOR 7 BITUMEN ALUMINIUM Test Test Method Solvent Based Primer Reflective Polymer Modified Coating Colour (In liquid state) Black Brilliant Aluminium (Dried Film) Semi-Matt Brilliant Aluminium Sheen Composition Bitumen, Petroleum solvents Bitumen, Petroleum solvents, highly polished aluminium flakes Drying time on concrete (20 ˚C to 40 ˚C) Hrs. To touch ASTM-D-2939 2 30 min Bone Dry 6 2 Density (Kg/liter) @ 25˚C ASTM-D-2939 0.9 0.99 Residue By Evaporation ASTM-D-2939 - - Resistance to water ASTM D-2939 - Good resistance Under drainage Poor resistance under standing water Heat Test, 100˚C ASTM D-2939 - No sagging or blistering Flammability Flammable Flammable Reflectance, % - 70 (min.) Viscosity @ 25˚C., cps ASTM D-2669 16 – 19 Seconds FC4 Low viscosity liquid Non - volatile, % Wt. ASTM D 402 50 - 60 52 - 60 Volatile, % Wt ASTM D 402 40 - 50 40 - 48 Coverage Depending on type of substrate and its condition ASTM D 5147 8.6 m²/litre at 35 μm DFT, allow loss factors 15.5 m²/litre at 20 µm DFT, on steel 7-8 m²/litre at 30-40 µm DFT, on bituminous surfaces Shelf life ( in factory seal container, if Stored in a shaded ventilated area) 12 months minimum at 25°C 12 months minimum at 25°C Container Size 5 and 20 Lt 5, 20 and 200 Lt KEY TO APPLICATIONS For priming dry concrete decks. Used as a primer for ‘Torch-on’ bituminous waterproofing and for protecting cast iron pipes, fence posts and metal railings etc. where handling is minimal. Used as a decorative and protective reflective coating over tar and bitumen based surfaces to protect them against ultraviolet degradation. For use on bitumen coated roofs, ‘Torch on’ bituminous waterproofing, bitumen coated cast iron pipes, fence posts etc. Specialized Coating Systems (Pty) Ltd National Call Centre: 086 137 2468 E-mail: [email protected] Web: www.speccoats.co.za APP STANDARD MODIFIED BITUMEN WATERPROOFING MEMBRANES NiloPlast ® APP STANDARD MODIFIED BITUMEN WATERPROOFING MEMBRANES NiloPlast ® Product Selector Guide Product Selector Guide

Upload: others

Post on 10-Nov-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NiloPlast - Specialized Coatings · Compound Elongation % UNI 8202/8-Membrane Properties Mechanical Properites Tensile Strength - Longitudinal N/50 mm EN-12311-1 350 650 800 900 1000

COLD APPLIED BITUMINOUS COATS

Group Primer and Topcoat

PRODUCT NAME BITUMINOUS PRIMER APEXIOR 7 BITUMEN ALUMINIUM

Test Test Method Solvent Based Primer Reflective Polymer Modified Coating

Colour (In liquid state) Black Brilliant Aluminium

(Dried Film) Semi-Matt Brilliant Aluminium Sheen

Composition Bitumen, Petroleum solvents Bitumen, Petroleum solvents, highly polished aluminium flakes

Drying time on concrete (20 ˚C to 40 ˚C) Hrs. To touch

ASTM-D-2939

2 30 min

Bone Dry 6 2

Density (Kg/liter) @ 25˚C ASTM-D-2939 0.9 0.99

Residue By Evaporation ASTM-D-2939 - -

Resistance to water ASTM D-2939 - Good resistance Under drainage Poor resistance under standing water

Heat Test, 100˚C ASTM D-2939 - No sagging or blistering

Flammability Flammable Flammable

Reflectance, % - 70 (min.)

Viscosity @ 25˚C., cps ASTM D-2669 16 – 19 Seconds FC4 Low viscosity liquid

Non - volatile, % Wt. ASTM D 402 50 - 60 52 - 60

Volatile, % Wt ASTM D 402 40 - 50 40 - 48

Coverage Depending on type of substrate and its condition

ASTM D 5147 8.6 m²/litre at 35 μm DFT, allow loss factors 15.5 m²/litre at 20 µm DFT, on steel7-8 m²/litre at 30-40 µm DFT, on bituminous surfaces

Shelf life ( in factory seal container, if Stored in a shaded ventilated area)

12 months minimum at 25°C 12 months minimum at 25°C

Container Size 5 and 20 Lt 5, 20 and 200 Lt

KEY TO APPLICATIONSFor priming dry concrete decks. Used as a primer for ‘Torch-on’

bituminous waterproofing and for protecting cast iron pipes, fence posts and metal railings etc. where handling is minimal.

Used as a decorative and protective reflective coating over tar andbitumen based surfaces to protect them against ultraviolet degradation. For use on bitumen coated roofs, ‘Torch on’ bituminous waterproofing,

bitumen coated cast iron pipes, fence posts etc.

Specialized Coating Systems (Pty) Ltd

National Call Centre: 086 137 2468E-mail: [email protected]

Web: www.speccoats.co.za

APP STANDARD MODIFIED BITUMEN WATERPROOFING MEMBRANES

NiloPlast®

APP STANDARD MODIFIED BITUMEN WATERPROOFING MEMBRANES

NiloPlast®

Product Selector GuideProduct Selector Guide

Page 2: NiloPlast - Specialized Coatings · Compound Elongation % UNI 8202/8-Membrane Properties Mechanical Properites Tensile Strength - Longitudinal N/50 mm EN-12311-1 350 650 800 900 1000

SUMMARY OF TECHNICAL CHARACTERISTICS PLASTOMERIC STANDARD MODIFIED BITUMEN MEMBRANES

Type Of Membrane APP Membranes with Fiberglass or Spun-bond Polyester Reinforcement

Group APP NiloPlast Range

Properties

Product Product Name NiloPlast NiloPlast 5 NiloPlast 10 NiloPlast 15 NiloPlast 20Reinforcement

G: Glassfiber GF: Low wt. GP: Med. wt.P: Polyester PP: Low wt. PS: Med. wt.PX: Med./High wt. PY: High wt. PZ: Heavy Duty

GF PP PS PX PY PZ GF PP PS PX PY PZ GF PP PS PX PY PZ GP PP PS PX PY PZ GP PP PS PX PY PZ

Test Unit Test Method

Dimensional Properties

Thickness mm EN-1849-1 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

Product Weight (Mass Per Unit Area) kg/m² EN-1849-1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Determination Of Width m EN-1848-1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Determination Of Length m EN-1848-1 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

Straightness (Ortometry) mm EN-1848-1 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10

Compound Properties

Softening point (R&B) oC ASTM D- 36 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150

Compound Elongation % UNI 8202/8 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Mem

bran

e Pr

oper

ties

Mec

hani

cal P

rope

rite

s

Tensile Strength - Longitudinal N/50 mm EN-12311-1 350 650 800 900 1000 1100 350 650 800 900 1000 1100 350 650 800 900 1000 1100 400 650 800 900 1000 1100 400 650 800 900 1000 1100

Tensile Strength - Transverse N/50 mm EN-12311-1 250 400 550 650 700 900 250 400 550 650 700 900 250 400 550 650 700 900 300 400 550 650 700 900 300 400 550 650 700 900

Elongation At Break - Longitudinal % EN-12311-1 2 30 30 35 40 45 2 30 30 35 40 45 2 30 30 35 40 45 2 30 30 35 40 45 2 30 30 35 40 45

Elongation At Break - Transverse % EN-12311-1 2 35 35 35 40 50 2 35 35 35 40 50 2 35 35 35 40 50 2 35 35 35 40 50 2 35 35 35 40 50

Tear Resistance - Longitudinal (Nail-Shank) N EN-12310-1 125 200 250 250 250 250 130 250 275 275 275 300 130 250 275 275 275 300 140 250 275 275 275 300 140 250 275 275 275 300

Tear Resistance - Transverse (Nail-Shank) N EN-12310-1 150 250 250 250 300 300 150 275 275 350 350 350 150 275 275 350 350 350 190 275 275 350 350 350 190 275 275 350 350 350

Tensile Tear Resistance - Longitudinal N ASTM D- 5147 . D 4073 450 550 600 625 750 800 450 550 600 625 750 800 450 550 600 625 750 800 450 550 600 625 750 800 450 550 600 625 750 800

Tensile Tear Resistance - Transverse N ASTM D- 5147 . D 4073 300 325 350 450 550 600 300 325 350 450 550 600 300 325 350 450 550 600 300 325 350 450 550 600 300 325 350 450 550 600

Resistance to Static Loading Kg EN 12730 Method A 7 15 15 20 25 25 7 15 15 20 25 25 7 15 15 20 25 25 7 15 15 20 25 25 7 15 15 20 25 25

Dynamic Puncturing (Impact Resistance) mm EN 12691 Method B 300 450 600 700 900 1100 300 450 600 700 900 1100 300 450 600 700 900 1100 300 450 600 700 900 1100 300 450 600 700 900 1100

Ther

mal

Pr

oper

ties

Flow Resistance At Elevated Temperature oC EN-1110 100 100 100 100 100 100 100 100 100 100 100 100 110 110 110 110 110 110 120 120 120 120 120 120 120 120 120 120 120 120

Flexibility At Low Temperature (1) oC EN-1109 -5 to 0 -10 to -5 -15 to -10 -20 to -15 ≤ -20Dimensional Stability % EN-1107-1 ±0.1 ±0.5 ±0.5 ±0.5 ±0.5 ±0.5 ±0.1 ±0.5 ±0.5 ±0.5 ±0.5 ±0.5 ±0.1 ±0.5 ±0.5 ±0.5 ±0.5 ±0.5 ±0.1 ±0.5 ±0.5 ±0.5 ±0.5 ±0.5 ±0.1 ±0.5 ±0.5 ±0.5 ±0.5 ±0.5Water ImpereablilityWatertightness at Low pressure

60 Kpa EN-1928 Method A pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass pass passWater Impereablility- Watertightness at High pressure (2) Kpa EN-1928 Method B 100 150 200 300 350 400 100 150 200 300 350 400 100 150 200 300 350 400 100 150 200 300 350 400 100 150 200 300 350 400

Mis

cella

neou

s P

rope

rtie

s

Water Absorption % ASTM D-5147 <1 <1 <1 <1 <1

Vapour Permeability µ EN 1931 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000

Fatigue resistance on cracks200 cycles

UNI 8202/13- Passed Passed Passed Passed Passed - Passed Passed Passed Passed Passed - Passed Passed Passed Passed Passed - Passed Passed Passed Passed Passed - Passed Passed Passed Passed Passed

500 cycles - - - Passed Passed Passed - - - Passed Passed Passed - - - Passed Passed Passed - - - Passed Passed Passed - - - Passed Passed Passed

Shear Resistance Of joints - Longitudinal N/50 mm EN-12317-1 350 650 800 900 1000 1100 350 650 800 900 1000 1100 350 650 800 900 1000 1100 400 650 800 900 1000 1100 400 650 800 900 1000 1100

Shear Resistance Of joints - Transverse N/50 mm EN-12317-1 250 400 550 650 700 900 250 400 550 650 700 900 250 400 550 650 700 900 300 400 550 650 700 900 300 400 550 650 700 900Thermal Ageing in air (in oven 28 days at 70˚C)

- UNI 8202 /26 Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed PassedAgeing Due To Atmospheric Agents (U.V Test weathering)

- ASTM G 53 - UNI 8202/29 Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed Passed

Fatigue resistance at Joints200 cycles

UNI 8202/32- Passed Passed Passed Passed Passed - Passed Passed Passed Passed Passed - Passed Passed Passed Passed Passed - Passed Passed Passed Passed Passed - Passed Passed Passed Passed Passed

500 cycles - - - Passed Passed Passed - - - Passed Passed Passed - - - Passed Passed Passed - - - Passed Passed Passed - - - Passed Passed PassedFire Classification - External Fire Performance

Class EN 13501-5 / ENV 1187 F Roof F Roof F Roof F Roof F Roof

Reaction to fire Class EN 13501-1 E E E E E

Adhesion Of Granules % EN-12039 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Adhesion To Concrete (Torch Applied) N/50 mm Pelage UEAtc 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20

Resistance to root penetration - EN 13948 NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD NPD

Supply Data

Weight kg/m² - 3 to 6 3 to 6 3 to 6 3 to 6 3 to 6

Thickness mm - 2 to 5 2 to 5 2 to 5 2 to 5 2 to 5

Roll Length M - 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

Roll Width M - 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Surface finish E: Polyethylene film S: Sand SL: Slates GR: Granule

Upper Surface Finish - - S or E or SL or GR S or E or SL or GR S or E or SL or GR S or E or SL or GR S or E or SL or GR

Lower Surface Finish - - S or E S or E S or E S or E S or E

KEY TO APPLICATIONSMulti-purpose membranes for Roofing & Waterproofing applications subjected to

different mechanical stresses and to:Normal Weathering Conditions Moderate Weathering Conditions Significant Weathering Conditions Critical Weathering Conditions Extreme Weathering Conditions

• The declared average values represent the best performance achieved at the present state of our knowledge, BituNil S.A.E. reserves the right to change, without warning, the technical characteristics in order to make the product more responding to the application requirements. The choice of the type of membrane for the kind of use is at the client’s discretion.• This Product Selector Guide is considered BituNil’s most updated reference for BituNil’s products.• All information / Values, listed in this guide may supresede relevenat information / values listed in equivalent product(s) technical data sheet.

*Tolerances for the above as per Products TDS

(1) Exact value depends on thickness of product.(2) Deviating from the standard method , The assesment is made in 1 Hour test 4mm or 4.5 Kg/m² products.