nh data shts 11 17-10

6
website: http://www.americanlimetec.com email: [email protected] telephone: 773.286.0566 LAST REVISED 2010-11-16 COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions. * Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies. Typical Wall System: Standard 2x6 Wood Frame Wall with Fiber Cement Board Siding Primed and Painted Interior Finish Gypsum Board Gypsum Board Tape and Mud Fastener at Gypsum Board Joint Vapor Barrier 2X6 Wood Stud, 16” O.C. Blown-In Insulation 1/2” Exterior Sheathing Sheathing Fasteners House Wrap Fiber Cement Board Lap Siding Siding Fastener Base Furring with Fastener NH FC-01 RESIDENTIAL CUT-AWAY WALL SECTION Insulative R-Value 18.1 Efficiency of Construction (# of Trades) 5 Approximate Wall Thickness 7” Embodied Carbon Dioxide Output* in kilograms per square foot +10.8 Recyclable or Biodegradable Content 71% Materials with Volatile Chemical Content 9% Approximate Cost Per Square Foot $16

Upload: limetech

Post on 16-Apr-2017

1.156 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Nh data shts 11 17-10

website: http://www.americanlimetec.comemail: [email protected]

telephone: 773.286.0566LAST REVISED 2010-11-16

COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.

The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions.

*Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies.

Typical Wall System:Standard 2x6 Wood Frame Wall with Fiber Cement Board Siding

Primed and Painted Interior Finish

Gypsum Board

Gypsum Board Tape and Mud

Fastener at Gypsum Board Joint

Vapor Barrier

2X6 Wood Stud, 16” O.C.

Blown-In Insulation

1/2” Exterior Sheathing

Sheathing Fasteners

House Wrap

Fiber Cement Board Lap Siding

Siding Fastener

Base Furring with Fastener

NH FC-01RESIDENTIAL CUT-AWAY WALL SECTION

Insulative R-Value 18.1

Efficiency of Construction (# of Trades) 5

Approximate Wall Thickness 7”

Embodied Carbon Dioxide Output*in kilograms per square foot

+10.8

Recyclable or Biodegradable Content 71%

Materials with Volatile Chemical Content 9%

Approximate Cost Per Square Foot $16

Page 2: Nh data shts 11 17-10

website: http://www.americanlimetec.comemail: [email protected]

telephone: 773.286.0566LAST REVISED 2010-11-16

COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.

*Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies.

The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions.

Typical Wall System:Standard 2x6 Wood Frame Wall with Brick Veneer

Primed and Painted Interior Finish

Gypsum Board

Gypsum Board Tape and Mud

Fastener at Gypsum Board Joint

Vapor Barrier

2X6 Wood Stud, 16” O.C.

Batt Insulation

1/2” Exterior Sheathing

Sheathing Fastener

House Wrap

Brick Tie

Air Cavity

Brick Veneer

Flashing with Continuous Fastener Strip

Mortar Net at Base of Air Cavity

Weep Vent

Stainless Steel Counterflashing

NH BV-01RESIDENTIAL CUT-AWAY WALL SECTION

Insulative R-Value 17.5

Efficiency of Construction (# of Trades) 5

Approximate Wall Thickness 11.5”

Embodied Carbon Dioxide Output*in kilograms per square foot

+9

Recyclable or Biodegradable Content 11%

Materials with Volatile Chemical Content 61%

Approximate Cost Per Square Foot $25

Page 3: Nh data shts 11 17-10

website: http://www.americanlimetec.comemail: [email protected]

telephone: 773.286.0566LAST REVISED 2010-11-16

COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.

The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions.

*Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies.

Typical Wall System:Standard CMU Wall with Stucco Exterior

Primed and Painted Interior Finish

Gypsum Board

Gypsum Board Tape and Mud

Fasteners at Gypsum Board Joint

2X2 Wood Furring, 16” O.C.

1 1/2” Rigid Insulation

8” CMU (Concrete Masonry Unit)

CMU Wire Reinforcement

House Wrap

Stucco Reinforcing Mesh

Stucco Base Coat

Stucco Finish Coat

Paint Coat

Stainless Steel Weep Screed

NH S-01RESIDENTIAL CUT-AWAY WALL SECTION

Insulative R-Value 6.5

Efficiency of Construction (# of Trades) 6

Approximate Wall Thickness 10.75”

Embodied Carbon Dioxide Output*in kilograms per square foot

+16.3

Recyclable or Biodegradable Content 5%

Materials with Volatile Chemical Content 15%

Approximate Material Cost Per Sq. Foot $25

Page 4: Nh data shts 11 17-10

website: http://www.americanlimetec.comemail: [email protected]

telephone: 773.286.0566LAST REVISED 2010-11-16

COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.

*Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies.

The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions.

Typical Wall System:Standard Light-Gauge Metal Frame Wall with EIFS (Exterior Insulation Finish System)

Primed and Painted Interior Finish

Gypsum Board

Gypsum Board Tape and Mud

Vapor Barrier

6” Light Gauge Metal Framing, 24” O.C.

Fastener at Sheathing

Fasteners at Gypsum Board Joint

Batt Insulation

1/2” Sheathing

Air Barrier Wrap

Rigid Insulation Adhesive

2” Rigid Insulation

EIFS Reinforcing Mesh

EIFS Base Coat

EIFS Finish Coat

Paint Coat

Flashing with Continuous Fastener Strip

NH EIFS-01COMMERCIAL CUT-AWAY WALL SECTION

Insulative R-Value 18.7

Efficiency of Construction (# of Trades) 5

Approximate Wall Thickness 9.75”

Embodied Carbon Dioxide Output*in kilograms per square foot

+13.2

Recyclable or Biodegradable Content 6%

Materials with Volatile Chemical Content 88%

Approximate Material Cost Per Sq. Foot $22

Page 5: Nh data shts 11 17-10

website: http://www.americanlimetec.comemail: [email protected]

telephone: 773.286.0566LAST REVISED 2010-11-16

COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.

The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions.

*Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies.

Typical Wall System: Standard Precast Concrete Wall

Primed and Painted Interior Finish

Gypsum Board Tape and Mud

5/8” Gypsum Board

Vapor Barrier

Fasteners at Gypsum Board Joint

2” Light Gauge Metal Furring Channels, 24” O.C.

2” Rigid Insulation

Precast Concrete Wall Panel

Precast Steel Rebar Reinforcement Grid

Prime and Paint Coat

Steel Rebar Reinforcement Grid (welded to Precast Wall Panel Rebar before Concrete Slab is Poured)

Fluid-Applied Foundation Waterproofing Membrane (below grade)

NH PC-01COMMERCIAL CUT-AWAY WALL SECTION

Insulative R-Value 7.5

Efficiency of Construction (# of Trades) 5

Approximate Wall Thickness 9”

Embodied Carbon Dioxide Output*in kilograms per square foot

+11.4

Recyclable or Biodegradable Content 66%

Materials with Volatile Chemical Content 25%

Approximate Cost Per Square Foot $29

Page 6: Nh data shts 11 17-10

website: http://www.americanlimetec.comemail: [email protected]

telephone: 773.286.0566LAST REVISED 2010-11-16

COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.

*Source: Athena Institute and University of Minnesota, US Life Cycle Inventory Database, EcoCalculator for Assemblies.

The above figures are estimated with common building materials and practices, and are not specific to any single manufacturer. It reflects the performance of mid-wall conditions only and does not take into account floor, roof, corner, opening or mechanical conditions.

Typical Wall System:Standard CMU Wall with Brick Veneer

Primed and Painted Interior Finish

Gypsum Board

Gypsum Board Tape and Mud

Vapor Barrier

3 5/8” Light-Gauge Metal Framing, 24” O.C.

Batt Insulation

Fasteners at Gypsum Board Joint

CMU Wire Reinforcement

8” CMU (Concrete Masonry Unit)

Brick Tie

Air Barrier Wrap

2” Rigid Insulation

Air Cavity

Brick Veneer

Mortar Net at Base of Air Cavity

Flashing with Continuous Fastener Strip

Weep Vent

Stainless Steel Counterflashing

NH BV-02COMMERCIAL CUT-AWAY WALL SECTION

Insulative R-Value 17.6

Efficiency of Construction (# of Trades) 5

Approximate Wall Thickness 18.5”

Embodied Carbon Dioxide Output*in kilograms per square foot

+21.8

Recyclable or Biodegradable Content 4%

Materials with Volatile Chemical Content 35%

Approximate Cost Per Square Foot $42