hc data shts 11 17-10
TRANSCRIPT
website: http://www.americanlimetec.comemail: [email protected]
telephone: 773.286.0566LAST REVISED 2010-11-16
COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.
Tradical® Hemcrete® Wall System:Internal Wood Frame with Lime Render Exterior
Vapor Permeable Paint (2 Coats)
Vapor Permeable Magnesium Board
Tape and Mud at Magnesium Board Joint
Magnesium Board Fastener
2X4 Wood Stud, 16-24” O.C.
Tradical® Hemcrete® (variable thickness to suit required thermal performance)
5/8” Baumit FL68 Lime Render Base Coat
1/8” Pre-colored Baumit SEP02 Lime Render Top Coat
Flashing
Metal Stop Bead at Bottom Edge of Lime Render
Brick Veneer at Exposed Foundation
Details are indicative only and need to be made project specific.While reasonable care has been taken to ensure that the information included in this drawing was accurate at the time of issue, American Lime Technology reserves the right to change specifications at any time. Final detailing remains the responsibility of the designer due to site and client specific requirements.
HC LR-01RESIDENTIAL CUT-AWAY WALL SECTION
Insulative R-Value* 35.5
Efficiency of Construction (# of Trades) 2
Approximate Wall Thickness 13”
Embodied Carbon Dioxide Outputin kilograms per square foot
-4.1
Recyclable or Biodegradable Content 95%
Approximate Cost Per Square Foot $29
*R-value not adjusted for thermal mass.
The above figures reflect the performance of mid-wall conditions only and do not take into account floor, roof, corner, opening or mechanical conditions.
website: http://www.americanlimetec.comemail: [email protected]
telephone: 773.286.0566LAST REVISED 2010-11-16
COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.
HC LR-02RESIDENTIAL CUT-AWAY WALL SECTION
Tradical® Hemcrete® Wall System:Central Wood Frame with Lime Render Exterior
Vapor Permeable Paint (2 Coats)
1/8” Baumit RK38 or KG30 Interior Lime Plaster Top Coat
3/8” Baumit RK38 Interior Lime Plaster Base Coat
2X4 Wood Stud, 16-24” O.C.
Tradical® Hemcrete® (variable thickness to suit required thermal performance)
5/8” Baumit FL68 Lime Render Base Coat
1/8” Pre-colored Baumit SEP02 Lime Render Top Coat
Flashing
Stop Bead at Bottom Edge of Lime Render
Brick Veneer at Exposed Foundation
Details are indicative only and need to be made project specific.While reasonable care has been taken to ensure that the information included in this drawing was accurate at the time of issue, American Lime Technology reserves the right to change specifications at any time. Final detailing remains the responsibility of the designer due to site and client specific requirements.
Insulative R-Value* 35.5
Efficiency of Construction (# of Trades) 2
Approximate Wall Thickness 13”
Embodied Carbon Dioxide Outputin kilograms per square foot
-4.1
Recyclable or Biodegradable Content 98%
Approximate Cost Per Square Foot $29
*R-value not adjusted for thermal mass.
The above figures reflect the performance of mid-wall conditions only and do not take into account floor, roof, corner, opening or mechanical conditions.
website: http://www.americanlimetec.comemail: [email protected]
telephone: 773.286.0566LAST REVISED 2010-11-16
COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.
Details are indicative only and need to be made project specific.While reasonable care has been taken to ensure that the information included in this drawing was accurate at the time of issue, American Lime Technology reserves the right to change specifications at any time. Final detailing remains the responsibility of the designer due to site and client specific requirements.
Tradical® Hemcrete® Wall System:Internal Wood Frame with Brick Veneer Exterior
Vapor Permeable Paint (2 Coats)
Vapor Permeable Magnesium Board
Tape and Mud at Magnesium Board Joint
Magnesium Board Fastener
2X4 Wood Stud, 16-24” O.C.
Tradical® Hemcrete® (variable thickness to suit required thermal performance)
2x2 Wood Furring, 16-24” O.C.
Brick Tie
Furring Stop
Air Cavity (ventilated and drained)
Brick Veneer
Mortar Net at Base of Air Cavity
Brick Cavity Vent
Flashing
HC BV-01RESIDENTIAL CUT-AWAY WALL SECTION
Insulative R-Value* 29.9
Efficiency of Construction (# of Trades) 2
Approximate Wall Thickness 18”
Embodied Carbon Dioxide Outputin kilograms per square foot
-2.1
Recyclable or Biodegradable Content 96%
Approximate Cost Per Square Foot $35
*R-value not adjusted for thermal mass.
The above figures reflect the performance of mid-wall conditions only and do not take into account floor, roof, corner, opening or mechanical conditions.
website: http://www.americanlimetec.comemail: [email protected]
telephone: 773.286.0566LAST REVISED 2010-11-16
COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.
HC FC-01RESIDENTIAL CUT-AWAY WALL SECTION
Vapor Permeable Paint (2 Coats)
Vapor Permeable Magnesium Board
Tape and Mud at Magnesium Board Joint
Magnesium Board Fastener
2X4 Wood Stud, 16-24” O.C.
Tradical® Hemcrete® (variable thickness to suit required thermal performance)
2x2 Wood Furring, 16-24” O.C.
1x2 Vertical Wood Furring, 16-24” O.C.
Air Cavity (ventilated and drained)
Furring Stop
Fiber Cement Siding
Insect Mesh at Base of Air Cavity
Brick Veneer at Exposed Foundation Wall
Flashing
Details are indicative only and need to be made project specific.While reasonable care has been taken to ensure that the information included in this drawing was accurate at the time of issue, American Lime Technology reserves the right to change specifications at any time. Final detailing remains the responsibility of the designer due to site and client specific requirements.
Tradical® Hemcrete® Wall System:Internal Wood Frame with Fiber Cement Siding Exterior
Insulative R-Value* 29.9
Efficiency of Construction (# of Trades) 2
Approximate Wall Thickness 14”
Embodied Carbon Dioxide Outputin kilograms per square foot
-3
Recyclable or Biodegradable Content 95%
Approximate Cost Per Square Foot $29
*R-value not adjusted for thermal mass.
The above figures reflect the performance of mid-wall conditions only and do not take into account floor, roof, corner, opening or mechanical conditions.