multi h eng - salmson · axial suction, vertical discharge upwards. ... • monobloc pump, compact,...

8
1 Flow rates up to: 25 m 3 /h Head up to: 70 m CE Max. operating pressure: 10 bar Max.suction pressure: 6 bar Temperature range: – 15° to + 110°C Max. ambient temperature: + 40°C ND of ports: G11/4 to G2 MULTi-H OPERATING LIMITS N.T. N o 141-1/ENG - Ed.6/05-05 240 100 70 0 Qm/h 25 H m MULTi-H MULTi-V 3 STAINLESS STEEL MULTI-STAGE HORIZONTAL PUMPS 2 pole - 50 Hz 2 ranges: stainless steel 304 and 316L Pumping of clear non-loaded fluids in the housing. agricultural and industrial sectors: Conveyance - Overpressure Sprinkling - Irrigation Washing station Draining - Filling (ponds, pools, etc.) Heating - Air conditioning Water treatment (demineralization, filtering, etc.). And incorporation in all modular systems. Catchment from a well, spring, river, pond, etc. Pumped fluids: 304 range: clear non-aggressive liquids (drinking water, glycol water, etc.). 316L range: aggressive liquids (sea water, demineralized water, chlorinated water, etc.). • MULTI-H with single-phase motor • MULTI-H with three-phase motor • Hydraulic assembly ALL STAINLESS STEEL APPLICATIONS

Upload: ngohanh

Post on 08-Oct-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

1

Flow rates up to: 25 m3/h

Head up to: 70 m CE

Max. operating pressure: 10 bar

Max.suction pressure: 6 bar

Temperature range: – 15° to + 110°C

Max. ambient temperature: + 40°C

ND of ports: G11/4 to G2

MULTi-HOPERATING LIMITS

N.T. No 141-1/ENG - Ed.6/05-05

240

100

70

0 Qm/h25

Hm

MULTi-H MULTi-V

3

STAINLESS STEEL MULTI-STAGEHORIZONTAL PUMPS

2 pole - 50 Hz2 ranges: stainless steel 304 and 316L

Pumping of clear non-loaded fluids in thehousing. agricultural and industrial sectors:• Conveyance - Overpressure• Sprinkling - Irrigation• Washing station• Draining - Filling (ponds, pools, etc.)• Heating - Air conditioning• Water treatment (demineralization,

filtering, etc.).

And incorporation in all modular systems.Catchment from a well, spring, river,pond, etc.Pumped fluids:• 304 range: clear non-aggressive liquids

(drinking water, glycol water, etc.).• 316L range: aggressive liquids (sea water,

demineralized water, chlorinated water,etc.).

• MULTI-H with single-phase motor • MULTI-H with three-phase motor

• Hydraulic assembly ALL STAINLESS STEEL

APPLICATIONS

2

MULTi-H

STANDARD CONSTRUCTION

ADVANTAGES

DESIGN

HYDRAULIC PRESELECTION CHARTS

• Hydraulic part

ALL STAINLESS STEELHorizontal, centrifugal, not self-priming.Multi-stage from 2 to 6 stages.Axial suction, vertical discharge upwards.Impellers mounted directly on the motorshaft extension.Shaft leaktightness by standardized mechanical seal.Hydraulic assembly mounted at 8 pointson a lantern bracket.

• Motor

Standard ventilated.Extended shaft end.Single-phase motor with integrated thermalprotection, automatic reset.Capacitor incorporated in the terminal box.Guiding rolling bearings of the impeller shaftlubricated for life.

Speed of rotation : 2900 rpmWindings three-phase : 230-400 VSingle-phase : 230 VFrequency : 50 Hz

(option 60 Hz)Insulating class : FProtection index : IP 54

• Monobloc pump, compact, economical

and silent.

• Hydraulic assembly in stainless steel:

anti-corrosive safety and increased

pump service life.

• Motor rolling bearing fitted in the

front endshield, amply dimensioned

and leaktight.

• Suction rings between very thick cells-

insensitive to thermal expansion,

elimination of risks of seizing up.

• Maximum reliability - high efficiency

due to impeller profile limiting the

number of stages, shaft size and axial

thrust.

• Standardized mechanical seals,

+110°C maximum, maintenance free.

• Easy installation.

PUMP IDENTIFICATION

Main parts Materials

non-aggressive aggressive

liquids liquids

Body casing 304 st. steel 316L st. steel

Impellers 304 st. steel 316L st. steel

Cells (stage shell) 304 st. steel 316L st. steel

Pump shaft 316L st. steel 316L st. steel

Cell centring 304 st. steel 316L st. steel

Mecanical seal Carbon/ Tungsten carbide/

Ceramic Carbon

O’rings EPDM Ethylene Propylene VITON

Plugs 316L st. steel 316L st. steel

Fixing-support bearing Aluminium Aluminium

* Except MULTi-H1600 series

NB: 304 stainless steel (X5CrNi18-10) or 316L stainlesssteel (X2CrNiMo17-12) recommended materials offering veryconsiderable resistance to corrosion. Clean, clear, fibrelessliquids conveyed and only slightly loaded in sand/silica(40g/m

3maximum concentration).

S E - MMULTi-H 206 -

X V - T

T : Three-phase motorM : Single-phase motor

E : EPDMV : VITON

S : 304 Stainless steel

X : 316L Stainless steel

Nomber of stages

Niminal flow in m3

/h

Pump code

STAINLESS STEELMULTI-STAGEHORIZONTAL

Ql/min

Ql/s

30

0.5

40 50 70 100 150 200 400

1 1.5 2 3 4

Imp.gpm

Hm

Qm3/h 21 3

70

60

50

40

30

20

104 5 6 8 10 25

Hft

15

10 15 20 30 40 50

200

150

100

75

50

MULTi-H2 POLE-50 Hz

MULTi-H400MULTi-H200 MULTi-H1600MULTi-H800

3

MULTi-H

SECTION DRAWING

MECHANICAL SEAL PARTS LIST

1111 - Pump casing

• 1150 - Stage casing with return vane

• 1154 - Stage centring

• 1160 - Stage casing without return vane

• 2250 - Impeller

2410 - Impeller spacer

2460 A - Impeller adjusting washer

2460 B - Mechanical seal tapered ring

2520 - Impeller back-up ring

2540 - Thrower

2911 - Shaft end washer

• 3011 A - Rolling bearing - fan side

• 3011 B - Rolling bearing - pump side

• 3134 - Motor support foot

3180 - Lantern bracket

4213 - Ring casing

• 4220 - Rotating part Mechanical

• 4240 - Stationary part seal

• 4610 A - Round section joint ring (filling cap)

• 4610 B - Round section joint ring (draining cap)

• 4610 C - Round section joint ring (lantern

casing bracket)

6515 - Draining cap

6521 - Purging and filling cap

• 6545 - Circlip (back-up ring)

6571 - Motor tie bolt

• 8110 - Electric motor casing

• 9220 - Impeller shaft

• 9460 - Terminal cover seal

• 9820 - Fan

9822 - Fan cover

• 9825 - Motor terminal cover

• 9831 - Motor rear bearing

• 9860 - Capacitor

9902 A - Lantern casing bracket screw

9902 B - Shaft end screw

9902 C - Cle aning screw

9942 - Fan-type washer

9944 - Spring washer

9966 - Elastic pin

(•) Recommended spare parts

4240

1111 6521 4610A 1160 1150 2250 2410 2520 9902A 4610C 4213 9860 9825 9460 3011A 9944 9822 9820 9902C

9902B 9942 2911 6515 4610B 2460A 1154 6545 2460B 4220 4240 3180 2540 3011B 8110 9220 9966 3134 6571 9831

POMPE 6 ÉTAGES

POMPE 4 ÉTAGES

}4220

6 STAGE PUMP

4 STAGE PUMP

4

MULTi-H

HYDRAULIC PERFORMANCE – 200 AND 400 SERIES

1 2 3 4 5 60

10

20

30

40

50

60

70

80

1 2 3 4 5 60

10

20

30

40

50

0

2

4

6

8

1 2 3 4 5 60.0

0.2

0.4

0.6

0.8

1.0

206

206

205

205

204

204

203

203

202

202

Imp.gpm

HmMULTi-H200

2 POLE - 50Hz

η % (205)

% m

kW

Ql/minQl/s

30

0.2 0.6

50 70

1.1 1.5

90

Hft

200

150

100

50

6 9 13 17

NPSH

Qm3/h

Qm3/h

Qm3/h

NPSH (205)

1 2 3 4 5 6 7 8 90

10

20

30

40

50

60

70

80

11 22 33 44 55 66 77 88 990

60

40

20

0

6

4

2

11 22 33 44 55 66 77 88 990.0

0.3

0.6

0.9

1.2

1.5

HmMULTi-H400

2 POLE - 50Hz

Imp.gpm 7 15 22 29

406

405

404

403

402

Qm3/h

Qm3/h

Qm3/h

η % (405)

m

kW

% NPSH

406

405

404

403402

Ql/minQl/s

25

0.2 0.6

50 75

1.1 1.5 1.9 2.3

100 125

Hft

200

150

100

50

NPSH (405)

Hydraulic performance at actual speed

5

HYDRAULIC PERFORMANCE – 800 AND 1600 SERIES

Imp.gpmHftHm

Ql/min

Ql/s

55MULTi-H800

2 POLE - 50Hz

50

45

40

35

15

5

60

40

20

0

2.0

1.5

1.0

0

Qm /h3 2 3 4 5

6

4

2

0

% m

805

NPSH (802)

η % (802)

805

804

803

802

30

25

20

10

0

180

160

140

120

100

20

40

60

80

6 7 8 9 10 11 12 13 14 15 16

Qm /h3 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

NPSH80

0.5

Qm /h3 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

804

803

802

kW

0

50403020

50 100 150 200 250

1 2 3 4

Hydraulic performance at actual speed

MULTi-H

Imp.gpmHftHm

Ql/min

Ql/s

55MULTi-H1600

2 POLE - 50Hz

50

45

40

35

15

5

60

40

20

0

2.0

2.5

1.5

0

Qm /h3 4 8

6

4

2

0

% m

NPSH 1604

η % (1603)

30

25

20

10

0

180

160

140

120

100

20

40

60

80

12 16 20 24 28 32

4 8 12 16 20 24 28 32

4 8 12 16 20 24 28 32

Qm /h3

NPSH80

0.5

1.0

Qm /h3

1604

1603

1602

1602

1603

1604

kW

0

10080604020

100 200 300 400 500

2 4 6 8

6

MULTi-H

SECTIONAL VIEW OF THE INSTALLATION

Suction pump

Strainer foot valve

Low level

High level

min . 0.70m

0.10m

Ha

MIN.

Strainer

Town water

Hc

On-load pump on storage tank or town waternetwork (with dry running protection kit)

Maximum suction head (Ha) and minimum pump head(Hc) at nominal pump flow rate.

Fluid MULTi-H 200 MULTi-H 400/800/1600temperature Ha mCL Hc mCL Ha mCL Hc mCL+ 20°C 7 --- 7 ---+ 50°C 6 --- 6 ---+ 80°C 2.2 --- 3 ---+ 110°C --- 8.1 --- 7

These figures do not take into account load lossesin the suction duct.

7

MULTi-H

ELECTRICAL DATA AND DIMENSIONS

52

8.5 7

L1

H1

H2

L3

L2

L

NDD**

ND

S*

drainingØ 1/4

fillingØ 1/4

Ø 9

1 ~

3 ~

104

45

190

108

106

ÿ9

1 ~

3 ~

7 24 24

H 1

ph

.H 3

ph

.

* suction

** discharge

ORDER MOTOR PUMP MassREFERENCE P2 Ports L H H1 L1 L2 L3

1x 3x 3x Capacitor suction dischargekW 230 V 230 V 400 V µF NDA NDR mm mm mm mm mm mm kg

MULTi-H202-M 0.55 3.8 2.8 1.6 12 G1 G1 375 216 90 205 88 110 09.8

MULTi-H202-T – 192 08.9

MULTi-H203-M 0.55 3.8 2.8 1.6 12 G1 G1 375 216 90 205 88 110 09.8

MULTi-H203-T – 192 08.9

MULTi-H204-M 0.55 3.8 2.8 1.6 12 G1 G1 423 216 90 253 88 158 10.6

MULTi-H204-T – 192 09.7

MULTi-H205-M 0.75 4.8 3.1 1.8 16 G1 G1 423 216 90 253 88 158 12.2

MULTi-H205-T – 192 11.3

MULTi-H206-M 1.10 6.3 4.5 2.6 30 G1 G1 472 224 90 277 104 182 15.7

MULTi-H206-T – 447 192 88 12.9

MULTi-H402-M 0.55 3.8 2.8 1.6 12 G11/4 G1 375 216 90 205 88 110 09.8

MULTi-H402-T – 192 08.9

MULTi-H403-M 0.55 3.8 2.8 1.6 16 G11/4 G1 375 216 90 205 88 110 10.7

MULTi-H403-T – 192 09.8

MULTi-H404-M 0.75 4.8 3.1 1.8 16 G11/4 G1 423 216 90 253 88 158 12.2

MULTi-H404-T – 192 11.3

MULTi-H405-M 1.10 6.3 4.5 2.6 20 G11/4 G1 448 224 90 253 104 158 15.2

MULTi-H405-T – 423 192 83 12.9

MULTi-H406-M 1.50 9.5 6.1 3.5 30 G11/4 G1 472 224 90 277 104 182 17.8.0

MULTi-H406-T – 472 206 90 104 15.2

MULTi-H802-M 0.75 4.8 3.1 1.8 16 G11/2 G11/4 387 216 90 217 88 122 15.8

MULTi-H802-T – 192 10.6

MULTi-H803-M 1.10 6.3 4.5 2.6 20 G11/2 G11/4 412 224 90 217 104 122 14.5

MULTi-H803-T – 387 192 88 12.2

MULTi-H804-M 1.50 9.5 6.1 3.5 40 G11/2 G11/4 224 277 182 16.0

MULTi-H804-T – 472 206 90 104 15.8

MULTi-H805-T 1.85 – 8.0 4.6 – G11/2 G11/4 472 206 90 277 104 182 17.0

MULTi-H1602-T 1.50 – 6.6 3.8 – G2 G11/2 477 206 90 236 104 138 15.3

MULTi-H1603-T 1.85 – 8.55 4.95 – G2 G11/2 477 206 90 236 104 138 17.16

MULTi-H1604-T 2.50 – 10.1 5.85 – G2 G11/2 515 221 100 236 137 138 21.1

8

MULTi-H

ACCESSORIES FEATURES

a) Electrical- “T” types: Three-phase 230-400 V - 50 Hz- “M” types: Single-phase 230 V - 50 Hzwith capacitor integrated in terminal box.

- Motor protection by overload cut-outessential for three-phase motor.

- Connections to the motor terminalby stuffing-box.

b) Installation- On the solid base with fixing by foundationbolts.

- Suction pump assembly with compulsorystrainer foot valve, or on-load pump onstorage tank or on town water networkwith protection system against lack of water.

- Pump connection through flexible or rigidpiping.

c) PackagingPump supplied in cardboard packaging,without connection accessories.

d) MaintenanceReplacement of recommended spare parts(•) subject to wear and tear.

• Shut-off valves• Check valves• Strainer foot valve• Anti-vibratory sleeves• Suction kit• Bladder or galvanized tanks• Water hammer tanks• ME dry running protection kit• ACSON: ON/OFF control device and

protection against lack of water• 3-phase overload cut-out motor protection,

etc.

• Three-phase motor protection

overload cut-out

• ACSON: ON/OFF control device

and protection against lack of water

• Strainer foot valve• Check valve

• Anti-vibratory sleeves

• Water hammer tank • Bladder tank

• Shut-off valve

OPTIONS & ACCESSORIES

53 bd de la République - Espace Lumière - Bât. 6 - 78403 Chatou Cedex FRANCE

Tel: +33 (0) 820 873 624 - Fax: +33 (0)1 30 09 82 34 - www.salmson.com