moving to high performance design

63
Design Group April 30, 2014 Moving to High Performance Design

Upload: scott-bowman

Post on 10-Jun-2015

134 views

Category:

Design


3 download

DESCRIPTION

Discussion on use of the Integrative Design Process (a new credit in LEED v4) to get to high levels of sustainable performance using a LEED Platinum project as an example

TRANSCRIPT

Page 1: Moving to High Performance Design

Design GroupApril 30, 2014

Moving to High Performance Design

Page 2: Moving to High Performance Design

Carey Nagle

BNIM Architects

Scott Bowman

KJWW Engineering

Many slides are courtesy of BNIM Architects – Not all are referenced

Page 3: Moving to High Performance Design
Page 4: Moving to High Performance Design

Sustainability

Page 5: Moving to High Performance Design

Efficiency

Page 6: Moving to High Performance Design

High Performance

Page 7: Moving to High Performance Design

REGULATORY PRESSURES

Codes and Standards

Page 8: Moving to High Performance Design

Measure Performance?

• ASHRAE Standards (90.1)

• Energy Star

• Code (IECC)

• LEED

• IgCC

• Green Globes

• BREEAM

Page 9: Moving to High Performance Design

DOE 30%

Reduction

Target

Courtesy PNNL

ASHRAE 90.1-2013?

ASHRAE 90-1975 ASHRAE 90A-1980

ASHRAE 90.1-1999

ASHRAE 90.1-2001

ASHRAE 90.1-2007

ASHRAE 90.1-2004

ASHRAE 90.1-1989

ASHRAE 90.1-2010

ASHRAE Standard 90.1E

ne

rgy U

se

In

de

x (

19

75

Us

e =

10

0)

Year

1970 1975 1980 1985 1990

50

1995 20152000 20102005

110

100

90

80

70

60

14%

4.5%

.5%

12.3%

4.5%

18.5%

Page 10: Moving to High Performance Design

Courtesy USGBCLEED v4?

LEED

Page 11: Moving to High Performance Design

MOVING TO HIGH PERFORMANCE

Integrative Design

Page 12: Moving to High Performance Design

© 2 0 1 2

B N I M

© 2 0 1 2

B N I M

Page 13: Moving to High Performance Design

© 2 0 1 2

B N I M

Owner

Architects

Consultants

Utility Companies

INTEGRATE

=

UNITE

COLLABORATION + INTEGRATED DESIGN PROCESS

Page 14: Moving to High Performance Design

© 2 0 1 2

B N I M

Use Less

• Reduce Loads

• Passive

• Envelope

Use Efficiently

• System Selection

• High Efficiency

Make On Site

• Renewable Energy

• Portal to Future

Page 15: Moving to High Performance Design

Energy Modeling

• Key to High Performance

• Important to understand interaction

• Many approximations – manage expectations

• Know limits of software

• Understand gross assumptions!

• Move from isolated evaluations to bundling

• Set early goals – Measure against them often!

Page 16: Moving to High Performance Design

23%

44%

Page 17: Moving to High Performance Design

42%

15%

21%

Page 18: Moving to High Performance Design

Why kBtu/sf

• ASHRAE currently uses energy cost

• Dollars reflect some local energy utilization and market conditions

• Suppressed sources can obscure signals

– Natural Gas

– Renewable Energy (Wind or Solar)

• Need to measure true performance

• Location, Location, Location

– 28 kBtu/sf means something in Iowa

– What about Portland?

Page 19: Moving to High Performance Design

© 2 0 1 2

B N I M

© 2 0 1 2

B N I M

Page 20: Moving to High Performance Design

© 2 0 1 2

B N I M

Integration Leads to High Performance

Iowa Utilities Board / Office of Consumer AdvocateState of Iowa

Page 21: Moving to High Performance Design

© 2 0 1 2

B N I M

Total EUI :

28.0kBtu/sf/yr

% Reduction from code base EUI

60%Model for other

government & private sector entities

LEEDPlatinum

VISIONARY GOALS

Page 22: Moving to High Performance Design

© 2 0 1 2

B N I M

Building Area

44,640GSF

Cost

$204Per GSF

MODEST BUDGET

Page 23: Moving to High Performance Design

© 2 0 1 2

B N I M

REPLICATION + INNOVATION

REPLICATION INNOVATION• Passive Strategies First• Orientation + Planning• Shallow N-S Footprint depths• Daylighting• Natural Ventilation

FLOORPLAN

Page 24: Moving to High Performance Design

© 2 0 1 2

B N I M

REPLICATION + INNOVATION

REPLICATION INNOVATION• Passive Strategies First• Orientation + Planning• Shallow N-S Footprint depths• Daylighting• Natural Ventilation

FLOORPLAN

Page 25: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 26: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 27: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 28: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 29: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 30: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 31: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 32: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 33: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 34: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 35: Moving to High Performance Design

Replication + Innovation

REPLICATION INNOVATION

• Orientation• Shared Parking

• Independent of Power Plant

Page 36: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 37: Moving to High Performance Design

© 2 0 1 2

B N I M

Page 38: Moving to High Performance Design

REPLICATION INNOVATION

• Solid West & East Envelope• Mitigate Heat Gain• Mitigate Glare

Page 39: Moving to High Performance Design

REPLICATION INNOVATION

• Daylight / Windows• North Diffuse Daylight• Views

• Light Tubes• Daylight Responsive Dimming• Daylight Harvesting Sunscreen• 98% Daylighting

DAYLIGHTING STRATEGIES

Page 40: Moving to High Performance Design

REPLICATION INNOVATION

• Light Shelf• Screen Shade

• Daylight Harvesting Sunscreen• Parabolic Louver Blades

Page 41: Moving to High Performance Design

REPLICATION INNOVATION

• High Angle Summer Daylight• Low Angle Winter Daylight

Page 42: Moving to High Performance Design

REPLICATION INNOVATION

• Shorter Furniture Panel System Provides Full Daylighting 70% More of the Time as Compared to Existing

Page 43: Moving to High Performance Design

© 2 0 1 2

B N I M

REPLICATION INNOVATION

• Cost Effective Precast Envelope• Horizontal Windows

• Daylight Harvesting System Becomes the Architecture

Page 44: Moving to High Performance Design

REPLICATION INNOVATION

• Operable Windows • Weather Station• Building Automation System Alert• Systems Tie-In• Cost Effective

NATURAL VENTILATION

Page 45: Moving to High Performance Design

REPLICATION INNOVATION

• Good Thermal Envelope• Cost Effective Precast

• Thermal Bridging Mitigation• Non-Conductive Precast System• Material Duality

ENVELOPE

Page 46: Moving to High Performance Design

REPLICATION INNOVATION

• Passive Strategies• Geothermal• Energy Recovery

• Occupancy Sensors Per Workstation• Demand Controlled Ventilation• Building Automation System • Photovoltaic Panels

ENERGY STRATEGIES

Page 47: Moving to High Performance Design

19.1%of Building Energy Use

RENEWABLE ENERGY

REPLICATION INNOVATION

• Passive First • Employ Loads Efficiently• Employ as Funding Becomes

Available

Page 48: Moving to High Performance Design

Energy Monitoring

LEED Measurement & Verification

Electrical Circuits Monitored• Lighting• Plug Loads• Mechanical Equipment• General Building Loads• IT Equipment

Geothermal Loop

Data Collected by Capitol Complex Energy Management System

REPLICATION INNOVATION

• Ensures Intended Operation• Identifies Additional Savings• Provides Research and

Demonstration Data

Page 49: Moving to High Performance Design

RESULTS

$54,000 Annual Savings

Page 50: Moving to High Performance Design

16.7 – 77% saved

26%18%

24%20%

11%

Page 51: Moving to High Performance Design

Includes PV

75%

98%

Page 52: Moving to High Performance Design

Includes PV

75%

98%

Page 53: Moving to High Performance Design

MEASUREMENT AND VERIFICATION

Second Year M&V Results:

• Design Estimated Model EUI – with PV 28.1

• Monitored EUI – with PV 16.7

• Monitored EUI – without PV 21.2

Conclusions:

• Model over predicted pumping energy – software limited

• Model slightly over predicted lighting savings

• Plug loads are significantly lower than design expectations

• Corrected energy model tracks actual use well

• Tools supported good decision making!

Energy Star = 100

Page 54: Moving to High Performance Design

Awards and Recognitions

• AIA Committee On The Environment

– Top 10 Green Building Award 2012

– Top 10 Plus in 2014

• ASHRAE Technology Award

– Second Place in 2014

• AIA Central States Region Merit Award

• AIA Iowa Merit Award

• Des Moines’ Environmental Impact Awards

– Built Environment Award

Page 55: Moving to High Performance Design

http://bt.e-ditionsbyfry.com/publication/?i=200800&p=38

Page 56: Moving to High Performance Design

© 2 0 1 2

B N I M

Moving to High Performance Design

Questions?

Page 57: Moving to High Performance Design
Page 58: Moving to High Performance Design

SELF REPORTING GBCI CREDIT

Page 59: Moving to High Performance Design

SELF REPORTING GBCI CREDIT

Page 60: Moving to High Performance Design

SELF REPORTING GBCI CREDIT

Page 61: Moving to High Performance Design

SELF REPORTING GBCI CREDIT

Page 62: Moving to High Performance Design

SELF REPORTING GBCI CREDIT

Page 63: Moving to High Performance Design

SELF REPORTING GBCI CREDIT

See document

provided that can

be used to cut

and past the

suggested

information to