mounting instructions for keratwin k20 omega profile - … · mounting instructions for keratwin ®...
TRANSCRIPT
Mounting instructions for KeraTwin® K20 Omega profile
Substructure
The mounting of the basic substructure must be carried out according
to project-specific, static calculation.
- The profiles of the basic substructure have to be mounted perpendicularly
and in a flush way (hat-profile or alternative Z-profile).
- The omega system rails have to be precisely aligned horizontally and fastened at
the pre-cut slot holes at the edges by means of screws* or rivets**
- The distance of the rails in horizontal direction must correspond to the
longitudinal grid of the panels.
Pay attention
to profile butt
joint!
Important:
a profile butt joint
of the K20 omega
profiles behind a
panel is not
allowed!
See standard
technical Detail
drawings.
99mm
63mm
K20 with Omega-Profile Hat profile (or altern. Z-Profile) for basic substructure fixing the Omega-Profile horizontal alignment, distance = longitudinal grid click in the joint profile, for installation without joint profiles
size of the panels it has to be used spacers
Replacement of a panel Insert 2mm thick sheet metal in horizontal joint, press Hang the panel in the system rail from top towards upward and remove panel (possibly push on top of it the bottom. hang in the panels installed area upward in addition).
For further information, see the standard technical details of the system K20 which we will make available to you on request.
*A4 stainless steel screw 4.8x16mm, Article 659
** Al blind rivet 4.8x10mm, Article 658
We reserve the right to make technical changes. 09.2011
Hat profile
Z-Profile
Fix point
Sliding point
Installation of cut panels with OMEGA single piece
fix a statically approved Al- sheet inside the cut an OMEGA-single piece from the OMEGA rail take the measurement between the relevant grooves at the KeraTwin-panel
OMEGA-profile with screws or rivets in a
safe manner
fix the OMEGA-single piece (hook to hook) onto the Al-sheet extension install joint profile or spacer and the panels
Installation of cut panels with K20-Al-clamps
fix a statically approved Al- sheet inside the fix the K20 Al-single clamp #864 (at the edges #861 / #862) with +
rivets #675
OMEGA-profile with screws or rivets in a
safe manner
up to the clamp the joint profile can be installed above the clamp the joint keeps open!
+
stainless steel rivet, black ø3,2x9,5mm with extended bolt (Art. No. 675) Please use tools with extended (25mm) mouth die
subject to change without notice! 09.2011