MassTrak Solutions for
Clinical and Forensic Laboratories
[ ]2
Masstrak solutions for clinical and forensic l aboratories
Waters Corporation has more than
50-years experience creating
business advantages for laboratory-
dependent organizations by delivering
practical and sustainable solutions in
areas such as healthcare delivery,
environmental management,
food safety, and water quality.
[ ]3
Working with clinical and forensic laboratories around the world, we have pioneered an integrated portfolio of MassTrak™
Solutions that include separations science, mass spectrometry, consumables, laboratory information management soft-
ware, services and support. This comprehensive approach helps optimize your laboratory processes and minimize the risks
associated with your assays.
MassTrak Solutions bring the power of Waters technologies, including tandem mass spectrometry, in easy-to-use cost-
effective packages addressing therapeutic drug monitoring, endocrinology, toxicology and many other applications.
Waters innovations and laboratory solutions provide better accuracy and precision for your assays ensuring the highest
quality results available, are backed by Waters application scientists and supported worldwide by field application experts.
We are committed to helping your laboratory deliver the highest quality results with new levels of sample throughput,
shortened turnaround times as well as increases in sensitivity, specificity and flexibility.
ForenSiC T oxiCoLogy neWBorn SCreeningAMino ACid AnALy SiS
T Her APeU TiC drUg MoniT oringendoCrinoLogy
Masstrak solutions for clinical and forensic l aboratories
[ ]4
Masstrak solutions for clinical and forensic l aboratoriesMasstrak solutions set new standards for diaGnostic and research applications
Many of the assays performed in diagnostic and research laboratories involve the
identification and quantification of chemical species in complex biological matrices.
Today’s chemists demand more accurate and cost-effective analytical tools that can
be easily integrated into current laboratory practices.
LC/MS/MS and other chromatographic detectors are ideally suited to many
applications as the selectivity of the technique enables individual analytes to be
quantified confidently. MassTrak Solutions integrate chromatography, consumables,
mass spectrometry, software and support services for diagnostic and research
laboratories worldwide. Single-vendor support is also available through the Waters
dedicated Clinical teams.
Wat ers Masst rak syst eMs
MassTrak Systems incorporating ACQUITY UPLC® coupled with the ACQUITY TQ
Detector or Xevo™ TQ mass spectrometers raise the performance bar for diagnostic
and research analysis. These innovative benchtop instruments optimize your laboratory
workflow from setup to on-going analytical performance, providing ultimate sensitivity
and speed of analysis while eliminating significant time and cost per sample.
T he new MassTrak Amino Acid Analysis Solution expands Waters solid history in
the field of amino acid analysis by providing to clinical research scientists a total
integrated solution for full profile amino acid analysis from urine and plasma.
Waters innovative technology and solutions provide your laboratory an enduring
platform for quality results and optimized laboratory operations.
Proven Methods
Reduce your development and validation effort with
proven methods developed and rigorously tested by
Waters application scientists.
Global Application Expertise and Support
W herever your laboratory is, we have application experts
ready to support your application and laboratory work.
Fast Speed of Analysis
Enables high sample throughput and rapid turnaround
of time sensitive samples.
For DIAGNoSTIC AND reSeArCh lAborATorIeS, MASSTrAk SySTeMS provIDe:
Improved Specificity
Eliminates cross reactivity problems, resulting in excellent
identification and quantification of target compounds.
Increased Sensitivity
Give reliable results at low ng/mL levels,
especially important for emerging drug
therapies and endocrine applications.
Enhanced Flexibility
Provides the capability to screen and
quantify a wide range of target analytes using
the same system.
Masstrak solutions for clinical and forensic l aboratories
[ ]5
Masstrak solutions set new standards for diaGnostic and research applications
Tacrolimus
Sirolimus
Everolimus
Cyclosporin A
Clinical Biomarkers
Homocysteine
Methylmalonic Acid
25 OH Vitamin D
Steroid Analysis
Catecholamines and Metanephrines
Amphetamines
Opiates
Benzodiazepines
Cannabis and Metabolites
Psychotherapeutics
Inborn Errors of Metabolism
ap plicat ions include:
[ WAT erS ISN’T JUST
My INST rUMeNT
provIDer. They’re My
SCIeNTIFIC pArTNer. ]
ACQUITY UPLC TQD SYSTEM
John Engen, Ph.D.Associate Professor,
Chemistry & Chemical Biology,Northeastern University
Masstrak solutions for clinical and forensic l aboratoriesMasstrak solutions for therapeutic druG MonitorinG (tdM)
Precision
Linearity
Method Comparison
Recovery
Interference
Dilution
Accuracy
Reagent Stability
Patient Specimen Stability
Column Robustness
The Waters method for Tacrolimus has been in routine use worldwide
for several years and has proven to be very robust and reproducible.
An immunosuppressants reagent kit is available to further facilitate
laboratory implementation and ensure reliable results. The MassTrak
Immunosuppressants Reagent Kit is 510(k) cleared and CE marked to
the IVD Directive for the quantification of Tacrolimus in whole blood for
kidney and liver transplant patients as an aid in the management of
Tacrolimus therapy. The reagent kit has been extensively tested against
key criteria in three different laboratories, this degree of testing means
that you can rely on reproducible and accurate results in your laboratory.
These criteria include:
0.6 0.7 0.8 0.9 1 1.1 1.2 1.3 1.4 1.5 min
%
0
100Ascomycin
%
0
100Tacrolimus
Chromatogram illustrating the a 3 ng/mL tacrolimus concentration acquired on an Alliance/Quattro micro system.
LC/MS/MS is now widely used for the therapeutic drug monitoring of
immunosuppressive drugs in routine clinical laboratories around the
world. The increased specificity of LC/MS/MS enables the measurement
of immunosuppressive drugs with much improved precision and accuracy
when compared with the traditional immunoassay methods. This is of
particular benefit when the concentration of immunosuppressive
drugs is in the low ng/ml range, for example when they are used in
combination therapy. In high throughput laboratories LC/MS/MS
has also proved to be a cost effective alternative to immunoassay
based methods.
The challenges facing laboratories wishing to implement LC/MS/MS
for therapeutic drug monitoring can include a lack of laboratory staff
to develop, support or implement LC/MS methods, access to reliable
calibrators, QCs and Internal Standards, application and services
support. Waters has addressed these key challenges by supplying the
total system, methodology and consumables such as LC columns and
reagents for the quantification of Tacrolimus.
adVantaGes oF Masstrak clinical solutions For tHerapeutic druG MonitorinG
Cost Effective — low consumable and operating costs
Fast Analysis — less than two minute run times for high through put capability.
Excellent Specificity of LC/MS/MS — offers good accuracy and precision.
Small Instrument Footprint — requires minimal bench space allowing you to optimize expensive lab bench space.
Unmatched Sensitivity — enables reliable measurement at low nanogram/mL levels
ADvANTAGeS oF MASSTrAk ClINICAl SolUTIoNS For TherApeUTIC DrUG MoNITorING:
[ ]6
[ ]7
Masstrak solutions for clinical and forensic l aboratories
Masst rak iMMunosup pressant X e ruo kit proVides:
Consistent quality of calibration materials and internal standards enabling
repeatable, accurate results.
Total system including LC/MS/MS, methodology and reagents
are supplied and supported by Waters.
Savings on Immunoassay reagent costs can lead to instrument payback in less than 2 years.
Fast analysis < 2 minutes using ACQUITY UPLC TQD enables 30 samples to be analyzed per hour.
The results below were obtained using the MassTrak Immunosuppressants XE RUO Kit (part number 176001673).
The MassTrak Immunosuppressant XE RUO Kit eliminates your worries about sourcing reliable quality control (QC) materials, calibrators and
internal standards. The Kit includes a column, QC standards and calibrators specifically designed for use with ACQUITY UPLC TQD to ensure
reliable analyses. The results below were obtained using the MassTrak Immunosuppressants XE RUO Kit (part number 176001673). This is the
first commercially available kit from Waters to contain isotopically labelled internal standards for Everolimus and Cyclosporin A.
[ ]7
MassTrak Immunosuppressants XE RUO Kit
compound Mean (ng/ml) combined sd combined cV
Cyclosporin A48.0 1.76 3.7
392.9 23.10 5.9
713.9 27.94 3.9
Everolimus2.1 0.15 7.5
12.0 0.73 6.1
20.1 1.27 6.3
Sirolimus2.6 0.20 8.0
12.3 1.11 9.0
20.6 1.61 7.8
Tacrolimus2.8 0.16 6.0
11.8 0.35 3.0
21.5 0.46 2.2
Compound name: TacrolimusCorrelation coefficient: r = 0.998680, r2 = 0.997361Calibration curve: 0.0612355 * x + 0.00363735Response type: Internal Std ( Ref 1 ), Area * ( IS Conc. / IS Area )Curve type: Linear, Origin: Exclude, Weighting: 1/x, Axis trans: None
0 5 10 15 20 min
Resp
onse
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0.0 5.0 10.0 15.0 20.0 25.0 30.0 ng/mL
Resp
onse
0
0.25
0.50
0.75
1.00
1.25
1.50
1.75
2.00
Compound name: EverolimusCorrelation coefficient: r = 0.999706, r2 = 0.999413Calibration curve: 0.064383 * x + 0.0203155Response type: Internal Std ( Ref 1 ), Area * ( IS Conc. / IS Area )Curve type: Linear, Origin: Exclude, Weighting: 1/x, Axis trans: None
Chromatograms representing Everolimus (upper trace) signal responses for the lowest calibrator (1.4 ng/mL) and the corresponding internal standard (lower trace).
Calibration curve for Tacrolimus (X) overlaid with the Tacrolimus QC (◊) results.
Calibration curve for Everolimus (X) overlaid with the Everolimus (◊) results.
0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 min0
3.0e4
0
2.5e3
Internal Standard
Quanti�er
Masstrak solutions for research applications
T he following results were obtained using the MassTrak Immunosuppressant XE RUO Kit
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
Intra-day and Inter-day imprecision results from the analysis of external control materials.
Masstrak aMino acid analysis (aaa) solutions
[ ]8
ensures the highest quality of data is obtained in your laboratory with both ease and consistency. High resolution separations are achieved
using pre-qualified MassTrak AAA UPLC columns and mobile phases that lead to dependable chromatography for both quantitative and
qualitative facets of amino acid analysis.
By offering the highest level of control over the common variables in amino acid analysis, optimized methods and quality controlled
chemistries functioning in combination with preeminent ACQUITY UPLC technology, the MassTrak AAA
Solution provides a detailed approach to the successful analysis of every sample.
total analyt ical solut ion
T he MassTrak Amino Acid Analysis Solution represents
seamless integration of the ACQUITY UPLC technology
with innovative derivatization chemistry, consumables
and software. This total system approach to amino acid
analysis ensures that all of the necessary instrumentation,
chemistries and pre-optimized methods are delivered
simultaneously to provide an easy to use system with a
rapid start-up in your laboratory.
Amino acid analysis (AAA) from urine and plasma samples presents some unique challenges in the clinical research laboratory. Faced with the
need to report accurate results for 40 or more analytes with absolute clarity and confidence in a timely manner, amino acid analysis places
weighty demands upon any laboratory.
The need for a comprehensive AAA methodology that overcomes many of the limitations of conventional ion-exchange methods, such as long
run times, is clear. By design, the MassTrak AAA Solution encompasses each stage of the implementation providing a revolutionary approach to
amino acid analysis and the reporting of first-class quality data backed by consummate support - all from Waters. Placing a strong emphasis on
traditionally labor-intensive areas of amino acid analysis such as data processing, the MassTrak AAA Solution provides a comprehensive approach
to dependable amino acid profiles faster than ever before.
Masst rak aaa solut ion k its
MassTrak AAA Solution delivers a complete package of consumables, reagents and standards required for amino acid analysis. Providing sufficient
supplies for the analysis of more than 250 samples, each MassTrak AAA Solution Kit has been designed to deliver consistent performance with
unmatched convenience and ease of use.
Integrating pre-defined analytical methodologies with a fully-tested set of reagents, columns, vials and eluents, the MassTrak AAA Solution
MassTrak Amino Acid Analysis Solutions for the analysis of amino acids in physiological fluids.
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
ap plicat ion speciF ic installat ion, t raininG and QualiF icat ion
T he implementation of new equipment or analyses has often been
a time-consuming and frustrating process. Understanding the
needs of your laboratory to begin generating data of the highest
quality in as short a time as possible, the MassTrak AAA Solution
incorporates dedicated installation and training services from
Waters-certified MassTrak AAA Solution experts - but the support
doesn’t stop there. Continued highly skilled technical support
from Waters combined with application specific performance tests
guarantee optimized application and instrument performance for
the lifetime of your equipment.
[ ]9
PSer Hy
Pro
NH3
His
PEA
Asn
3MH Tau
1MH
Ser
Gln
Carn
Arg
Gly
Ans
EAA
sp
Sar
Glu Cit B-
Ala
Thr Al
a
GABA
AA
DAPr
oBA
IB Hyl1
Hyl2 AA
BACy
stOr
nCy
s
Lys
Tyr
Deriv
atiz
atio
n Pe
akM
etVa
l
Nva
Ile aIle
Leu
HCys Phe
Trp
HyPr
oNH
3Hi
sA
sn3M
HTa
u
Ser
Gln
Arg
Gly
Glu
Cit
Thr
Ala
Pro
AA
BA
Orn
Lys
Tyr
Deriv
atiz
atio
n Pe
akM
etVa
l
Nva
Ile
Leu
Phe
Trp
AMQ
AU
-0.02
0.00
0.02
0.04
0.06
0.08
0.10
0.12
0.14
0.16
0.18
0.20
4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 min
Full panel amino acid analysis complete inless than 35 minutes
Full panel amino acidanalysis complete inless than 35 minutes
Near baseline resolution ofisoleucine & allo-isoleucineNear baseline resolution ofisoleucine & allo-isoleucine
Derivatization by-productsare baseline resolved
Derivatization by-productsare baseline resolved
The combination of Waters award winning ACQUITY UPLC technology and market leading AccQ•Tag™ pre-column derivatization chemistry provides the robustness, reliability and ease of use required for trouble-free operation in your research laboratory.
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
Fast er tHan eV er BeFore
The MassTrak AAA Solution provides full profile amino acid analysis
faster than conventional methods. Separation of the 42 commonly
encountered physiological amino acids is provided in a little under
32 minutes with an inject-to-inject time of just over 45 minutes. As
well as making obvious contributions to throughput in your laboratory,
the MassTrak AAA Solution offers swift analyses even from a standing
start for those urgent samples.
Masstrak solutions for clinical and forensic l aboratories
Over the last few years, there has been a significant increase in
interest using LC/MS/MS analysis of small molecules associated with
endocrine disorders. LC/MS/MS systems have been adopted in many
clinical laboratories world-wide for the routine analysis of endocrine
related compounds such as:
25OH Vitamin D
Testosterone
Cortisol
Plasma Free Metanephrines
Aldosterone
Steroid Panels
For many of these analyses LC/MS/MS has been able to demonstrate
improved precision and accuracy when compared to commercially
available immunoassay methods, leading to improved clinical
decisions and consistent diagnosis.
0.25 0.5 0.75 1 1.25 1.5 1.75 2
%
0
100
MRM of 3 channels, ES+294.1 > 100.1
1.320e+006
Internal Standard0.05 ng/mL testosterone
Testosterone_d51.03
34944.20
%
0
100
MRM of 3 channels, ES+289.1 > 97.051.060e+004
Qualifier0.05 ng/mL testosterone
Testosterone1.04
279.06
%
0
100
MRM of 3 channels,ES+289.1 > 109.18.583e+003
Quantifier0.05 ng/mL testosterone
Testosterone1.04
227.37
Chromatogram illustrating a liquid-liquid extracted serum calibrator at 50 pg/mL (0.17 nM) on an ACQUITY UPLC and TQ detector system.
endocrinoloGy
[ ]10
0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 min
%
0
%
0
Cortisol
Androstenedione
17-OHP
100
100
Control
CAH Patient
Cortisol
Chromatograms to show the differences in the steroid profiles for a CAH patient and a control sample.
Masstrak solutions for clinical and forensic l aboratories
Scatter plot and Passing and Bablok fit.
neW Born sc reeninG
Tandem Mass Spectrometry is now established as the technique of
choice used for high throughput screening of inherited metabolic
disorders and as an aid to diagnosis of metabolic disorders in children
and adults. Over 5 million babies are currently being screened using
Waters LC/MS/MS systems.
Using tandem mass spectrometers, more than 30 metabolic disorders
can be detected from a single blood sample (taken within a week after
birth). Screening by LC/MS/MS can mean the difference between a
healthy life and one of severe disabilities or even death. In addition
to the obvious health benefits, system solutions can provide cost
benefits as early diagnosis can prevent costly health care in the
future. Prior to the use of LC/MS/MS, routine screening of newborns
was limited to three or five metabolic disorders – each requiring
a different test.
Waters has been involved in newborn screening since the mid
1990s. T he current ACQUITY UPLC TQD combination builds on
nearly 20 years of proven field experience and sets new standards
for performance, reliability and ease of use. T his solution is offered
in collaboration with Perkin Elmer.
NeoLynx browser enables easy interpretation of data.
Robust Analytical Methodology developed and validated by Waters Clinical Application Scientists.
Implementation and Support of LC/MS/MS assays on your site by Clinical Application Specialists.
Automated Sample pre-treatment protocols.
Fast Throughput without multiplexing.
Selectivity and Sensitivity enabling reliable measurement at low levels.
autoMat ed saMple preparat ion
To ensure accurate and reliable measurement, LC/MS/MS, assays for
endogenous compounds such as steroids, metanephrines and 25OH
Vitamin D, usually require sample pre-treatment steps prior to analysis.
To overcome laborious manual sample pre-treatment and potential er-
rors due to operator variablity, Waters has developed automated off-line
sample pre-treatment solutions to enable the successful implementation
in clinical laboratories optimizing work effectiveness.
[ ]11
Waters adVantaGe For endocrinoloGy applications:
Compound name: 25OHD3Correlation coefficient: r = 0.9996, r2 = 0.9993Calibration curve: 0.0286787 * x + 0.0166297Curve type: Linear, Origin: Exclude, Weighting: 1/x, Axis trans: None
0 20 40 60 80 100 120 140 160 180 200 220 ng/mL
Resp
onse
0
1
2
3
4
5
6
BRI [Total 25OHD] ng/mL
Wat
ers [
Tota
l 25O
HD] n
g/m
L
0
5
10
15
20
25
30
35
40
45
50
0 10 20 30 40 50
Identity
Passing & Bablok (I) fit(1.47 + 0.98x)
95% CI bands
Horse serum calibration curve for 25OHD3.
[ ]12
Masstrak solutions for clinical and forensic l aboratories
Traditionally, confirmation analysis of drugs of abuse was carried out by gas chromatography/mass spectrometry (GC/MS). However this can be
a time consuming and labor intensive procedure, as many drugs require derivatization and complex sample pre-treatment before they can be
analyzed by GC/MS. In addition, long GC run times limit sample throughput.
To address these challenges many laboratories are now employing LC/MS/MS systems to conduct their confirmatory analysis. At Waters, the
MassTrak Solutions approach minimizes your sample pre-treatment requirements and optimizes your laboratory throughput. The technique is
particularly useful for polar, non-volatile, thermally labile compounds which are difficult to analyze by gas chromatography-based techniques.
The introduction of UltraPerformance LC® has resulted in significant improvements for routine laboratory analysis. Methods are now faster, more
efficient in respect to resolution and ultimately more sensitive.
Some recent examples of our customer’s success with the implementation and routine use of UPLC, as highlighted by peer-reviewed
publication, include:
Sixty percent reduction in the analytical process for 8 drugs of abuse in a high throughput laboratory.
[ Ref: AACC Meeting Abstract, Washington, 2008; AIT Laboratories Inc.]
Identification of 130 analytes in a Doping Control Laboratory in less than 9 minutes.
[ Ref: J.Mass. Spectrom, 2008; 43: 980-992, John-Olof T hörngren et al.]
Masstrak systeMs for druGs of abuse analysis
[ ]13
Masstrak solutions for clinical and forensic l aboratories
adVantaGes oF Masstrak solutions For druG VeriFication and QuantiFication
[ ]13
1 1.5 2 2.5 3 3.5 4 4.5 5 min
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100 3 .51
3 .2 7
3 .2 6
3 .0 0
2.5 9
2 .4 4
1 .9 2
1 .89
1 1.5 2 2.5 3 3.5 4 4.5 5 min
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100
%0
1004 .8 1
4 .6 9
4 .5 7
4 .4 0
4 .2 2
4 .0 3
3 .8 9
3 .6 5
3 .5 6
IMIPRAMINE
PROTRIPTYLINE
DESIPRAMINE
PAROXETINE
DOXEPIN
CITALOPRAM
TRAZODONE
VENLAFAXINE
CLOMIPRAMINE
NORCLOMIPRAMINE
SERTRALINE
FLUOXETINE
TRIMIPRAMINE
NORFLUOXETINE
AMITRIPTYLINE
NORTRIPTYLINE
FLUVOXAMINE
Analyses without prior derivatization or complex sample
pre-treatment of Amphetamines, opiates, benzodiazepines,
GHB and many other drugs of abuse.
Higher sensitivity enabling volumne limited samples to
be used in addition to blood and urine. For example, using
UPLC/MS/MS, accurate quantification can be achieved from
as little as 50 microliters of oral fluid, benefitting the types
of analysis you can achieve.
Achieve quantification and verification of drugs of abuse in
a single LC run with a high degree of confidence.
Completed Application Notes that save you the time of
developing complex methods from basic principles, are
available for your review and immediate implementation at
www.waters.com/forensics
TargetLynx automatically flags out-of-range analytes.
TargetLynx™ allows you to monitor several qualifier transitions to confirm the presence of a specific drug. This application manager also includes a wide range of automatic validity checks, such as calculation of ion ratios and LC retention time tolerances, to provide confidence in reported results.
MRM chromatograms for 17 psychotherapeutic drugs in serum.
Analysis performed simultaneously by UPLC/MS/MS in 8 minutes.
ACQUITY Xevo TQ MS
Ref: Waters Application Note: 720002463
1 1.5 2 2.5 3 3.5 4 4.5 5 min
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100 3 .51
3 .2 7
3 .2 6
3 .0 0
2.5 9
2 .4 4
1 .9 2
1 .89
1 1.5 2 2.5 3 3.5 4 4.5 5 min
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100
%0
100
%0
1004 .8 1
4 .6 9
4 .5 7
4 .4 0
4 .2 2
4 .0 3
3 .8 9
3 .6 5
3 .5 6
IMIPRAMINE
PROTRIPTYLINE
DESIPRAMINE
PAROXETINE
DOXEPIN
CITALOPRAM
TRAZODONE
VENLAFAXINE
CLOMIPRAMINE
NORCLOMIPRAMINE
SERTRALINE
FLUOXETINE
TRIMIPRAMINE
NORFLUOXETINE
AMITRIPTYLINE
NORTRIPTYLINE
FLUVOXAMINE
[ ]14
Masstrak serVice solutions for clinical and forensic laboratories
syst eMatic toXicoloGical analysis [sta] and tarGet ed MrM sc reeninG.
Waters has developed two separate and complementary approaches to accurately identify unknown compounds, leveraging LC/MS/MS technologies:
For Systematic Toxicological Analysis: ChromaLynx™, for forensic toxicology is a unique data processing software tool ensures you routinely perform
faster analysis and data interpretation. ChromaLynx automates the process of extracting mass spectra from complex chromatograms and searching
against library spectra. When combined with UPLC, this results in rapid chromatography (e.g., run times reduced from 30 minutes to 15 minutes).
A chromatogram that would usually require hours of manual data analysis can now be processed in minutes using ChromaLynx.
The ChromaLynx™ browser shows; (i) the total ion chromatogram (TIC); (ii) the list of proposed candidates; (iii) the spectral match for function 5 (cone voltage 65 V), of one of the proposed compound candidates (EDDP). The spectrum view window allows a direct visual comparison of the acquired spectral data with the library data. In this example an excellent average Match Factor was observed i.e., 924 out of a possible max. 1000.
Alternatively, if your analysis requires a more targeted screening approach, you can use MRM [Multiple Reaction Monitoring] to increase the
selectivity and sensitivity for unknown compound identification. The ACQUITY TQD system uses the same 15 minute chromatography as with
the STA method, and in combination with a dedicated library containing the most frequently encountered toxicological compounds, ensures rapid
and reliable results from sample injection to injection. The TargetLynx software ensures that comprehensive reports are generated instantly after
samples are analyzed. The capability to then confirm and quantify any identified compounds using the same UPLC/MS/MS System ensures you
maintain the optimal laboratory efficiency.*
Both MassTrak screening solutions, including their respective compound libraries, are available without requiring additional method development.
*A separate validated method is necessary for any drug confirmation and quantification.
[ AT The eND oF The DAy, The
TeChNoloGy hAve leD To IMproveD TUrN
For oUr ClIeNTS, AND ThAT IS WhAT
(i) Chromatogram TIC
(ii) Candidatelisting
(iii) Spectrum view
[ ]15
Masst rak serV ice solut ions For clinical and Forensic laBoratories
achieve Maximum uptime
A MassTrak Clinical Service Plan is a comprehensive system package designed
for the clinical laboratory where instrument uptime is critical. It is the highest
priority service plan offered by Waters. All services and support are delivered
by Waters worldwide Field Service Engineers and dedicated teams of Clinical
Specialists. Their job is to ensure your success.
The plan delivers performance maintenance and the reassurance of fast on-site support:
Ensure reliable operation and minimize unscheduled downtime
Get applications and system support from dedicated Waters Clinical Solutions Experts
Fix the cost of ownership for your mission critical instruments
Save up to 30% over time and material repair costs
Eliminate the administrative costs of processing future multiple purchase orders.
service when you need it
Guaranteed priority two-hour call back, seven days a week
Guaranteed on-site response time of two business days (48 hours)
Annual Performance Maintenance on-site visit
Waters certified field service engineers
Labor and travel for on-site repair
Genuine Waters Quality Parts®
Remote monitoring and diagnostics
Discount on hardware upgrades
Firmware updates
Discounts on customer training.
service plan
An annual Performance Maintenance
visit keeps your Waters MassTrak System
running at optimal performance. During the
visit, your Waters certified field service
engineer replaces normal wear-and-tear
maintenance parts based upon a proven
protocol developed specifically for your
system. The engineer also looks for signs
of wear, corrosion, and damage to key
parts so we can correct problems before
they impact your productivity.
[ AT The eND oF The DAy, The
TeChNoloGy hAve leD To IMproveD TUrN
For oUr ClIeNTS, AND ThAT IS WhAT Michael A. Evans, Ph.D.
CEO, AIT Laboratories
beNeFITS oF WATerS
AroUND TIMeS
MATTerS MoST. ]
© 2009 Waters Corporation. Waters, ChromaLynx, Quattro micro, Alliance,
MassTrak, MassLynx, Xevo TQ, TargetLynx, Waters Quality Parts, ACQUITY, ACQUITY
TQ, ACQUITY TQD, UPLC, AccQ•Tag, UltraPerformance LC, Empower, NeoLynx and
The Science of What’s Possible, are trademarks of Waters Corporation.
All other trademarks are the property of their respective owners
720001139EN NOVEMBER 2009 VW-FP
sales offices
Select MassTrak systems and kits are in vitro diagnostic devices compliant with EU directive 98/79/EC and the
United States Food and Drug Administrative Quality System Regulations and current Good Manufacturing Practices.
Waters Corporation is ISO 13485:2003 certified.
Photographs on Pages 4-5 (top) and Page 15 (left) reproduced with permission of AIT Laboratories.
Austria and european export (Central South eastern europe, CIS and Middle east) 43 1 877 18 07
Australia 61 2 9933 1777
belgium 32 2 726 1000
brazil 55 11 5094-3788
Canada 1 800 252 4752 x2205
China 86 21 6879 5888
CIS/russia +497 727 4490/290 9737
Czech republic 420 2 617 1 1384
Denmark 45 46 59 8080
Finland 09 5659 6288
France 33 1 30 48 72 00
Germany 49 6196 400600
hong kong 852 29 64 1800
hungary 36 1 350 5086
India and India Subcontinent 91 80 2837 1900
Ireland 353 1 448 1500
Italy 39 02 265 0983
Japan 81 3 3471 7094
korea 82 2 6300 4800
Mexico 52 55 5524 7636
The Netherlands 31 76 508 7200
Norway 47 6 384 60 50
poland 48 22 833 4400
puerto rico 1 787 747 8445
Singapore 65 6593 7100
Spain 34 93 600 9300
Sweden 46 8 555 11 500
Switzerland 41 56 676 70 00
Taiwan 886 2 2543 1898
United kingdom 44 208 238 6100