    RADview Optimux-4E1/Optimux-4T1 Network Management Software Guide i

    Contents

    Chapter 1. Introduction

    1.1 Overview..................................................................................................................... 1-1

    General ................................................................................................................................1-1Features................................................................................................................................ 1-1

    Application ........................................................................................................................... 1-2

    1.2 Functional Description................................................................................................. 1-2Test and Diagnostic Capabilities............................................................................................1-2Fiber Optic Link....................................................................................................................1-2Tributary Interface Characteristics .........................................................................................1-3Alarms and Alarm Indications................................................................................................1-3

    Chapter 2. Installation and Setup

    2.1 Configuring for Management ....................................................................................... 2-1

    Setting up the Manager List................................................................................................... 2-2

    Setting the Management Access ............................................................................................2-2

    2.2 Connecting Optimux-4E1/Optimux-4T1 for Management............................................ 2-32.3 Configuring Optimux-4E1L/Optimux-4T1L Control Port for Management.................... 2-4

    Configuring the Control Port for PPP mode ...........................................................................2-4Returning the Control Port to Terminal Mode........................................................................ 2-4

    2.4 Using the Graphical User Interface .............................................................................. 2-5Menu Bar ............................................................................................................................. 2-6Status Bar .............................................................................................................................2-6LEDs..................................................................................................................................... 2-7

    2.5 System Level Operations.............................................................................................. 2-72.6 Device Level Operations.............................................................................................. 2-8

    2.7

    Port Level Operations.................................................................................................. 2-9

    Chapter 3. Configuration Management

    3.1 System Level Configuration Menu............................................................................. 3-1Viewing and Setting System Information................................................................................ 3-1Polling the Agents ................................................................................................................. 3-3

    3.2 System Level Options Menu ..................................................................................... 3-3Configuring the Manager List................................................................................................. 3-3Configuring Access Restrictions .............................................................................................3-5Configuring Automatic Polling...............................................................................................3-6

    3.3 Device Level Configuration Menu............................................................................. 3-6

    Configuring Device Parameters .............................................................................................3-6Viewing Interface Information ...............................................................................................3-8

    Resetting the Hardware.........................................................................................................3-9Resetting the Configuration...................................................................................................3-9

    3.4 Port Level Configuration Menu ............................................................................... 3-10Configuring Link Parameters ............................................................................................... 3-10Configuring Channel Parameters ......................................................................................... 3-12

  • 7/31/2019 Manual Optimux 4E1L

    4/50

    Table of Contents

    ii RADview Optimux-4E1/Optimux-4T1 Network Management Software Guide

    Chapter 4. Fault Management

    4.1 System Level Fault Management Fault Menu............................................................. 4-1Displaying the Alarm Buffer List.............................................................................................4-1Clearing the Alarm Buffer......................................................................................................4-3

    4.2 Device Level Fault Management Fault Menu............................................................. 4-3

    Displaying the Alarms ...........................................................................................................4-3Configuring Channel Alarm Masks.........................................................................................4-5

    4.3 Device Level Fault Management Diagnostics Menu................................................... 4-6Viewing the Lines Status........................................................................................................ 4-6Running a Loopback Test on a Device................................................................................... 4-7

    4.4 Port Level Fault Management Fault Menu................................................................. 4-8Displaying the Alarms for a Link ............................................................................................4-9Displaying the Alarms for a Channel.................................................................................... 4-10

    4.5 Port Level Fault Management Diagnostics Menu ..................................................... 4-11Running a Loopback Test on a Link.....................................................................................4-11Running a Loopback Test on a Channel ..............................................................................4-13

    List of Figures1-1 Typical Application.................................................................................................................. 1-2

    2-1. Host IP List Menu.................................................................................................................. 2-12-2. Manager List Screen .............................................................................................................. 2-22-3. Manager Access Menu........................................................................................................... 2-3

    2-4. Telnet Menu.......................................................................................................................... 2-3

    2-5. Management to Optimux-4E1 or Optimux-4T1 via Ethernet .................................................. 2-32-6. Management-to-MBE-to-Optimux-4E1L/4T1L Connection..................................................... 2-42-7. RADview Window................................................................................................................. 2-6

    3-1. System Level Configuration Menu ......................................................................................... 3-13-2. System Information Dialog Box.............................................................................................. 3-23-3. System Level Options Menu.................................................................................................. 3-33-4. Manager List Dialog Box........................................................................................................ 3-43-5. Access Dialog Box ................................................................................................................. 3-53-6. Device Level Configuration Menu ......................................................................................... 3-63-7. Local Parameters Dialog Box ................................................................................................. 3-73-8. Remote Parameters Dialog Box ............................................................................................. 3-7

    3-9. Local Interfaces Dialog Box ................................................................................................... 3-83-10. Remote Interfaces Dialog Box.............................................................................................. 3-83-11. Port Level Configuration Menu.......................................................................................... 3-103-12. Local Link Parameters Dialog Box...................................................................................... 3-103-13. Remote Link Parameters Dialog Box.................................................................................. 3-113-14. Local Channel Parameters Dialog Box ............................................................................... 3-123-15. Remote Channel Parameters Dialog Box ........................................................................... 3-12

  • 7/31/2019 Manual Optimux 4E1L

    5/50

    Table of Contents

    RADview Optimux-4E1/Optimux-4T1 Network Management Software Guide iii

    4-1. System Level Fault Menu....................................................................................................... 4-14-2. Alarm Buffer List Dialog Box.................................................................................................. 4-24-3. Device Level Fault Menu....................................................................................................... 4-34-4. Device Alarms Dialog Box ..................................................................................................... 4-44-5. Mask Channel Alarm Dialog Box ........................................................................................... 4-54-6. Device Level Diagnostics Menu............................................................................................. 4-64-7. Local Lines Status Dialog Box ................................................................................................ 4-64-8. Remote Lines Status Dialog Box............................................................................................. 4-7

    4-9. Local Loopback Test Dialog Box............................................................................................ 4-84-10. Port Level Fault Menu ......................................................................................................... 4-84-11. Link Alarms Dialog Box ....................................................................................................... 4-94-12. Channel Alarms Dialog Box ............................................................................................... 4-104-13. Port Level Diagnostics Menu ............................................................................................. 4-114-14. Link Loopback Test Dialog Box.......................................................................................... 4-124-15. Local Channel Loopback Test Dialog Box .......................................................................... 4-134-16. Remote Channel Loopback Test Dialog Box ...................................................................... 4-14

  • 7/31/2019 Manual Optimux 4E1L

    6/50

    Table of Contents

    iv RADview Optimux-4E1/Optimux-4T1 Network Management Software Guide

    List of Tables2-1. Optimux-4E1/Optimux-4T1 LEDs.......................................................................................... 2-72-2. System Management Options................................................................................................ 2-72-3. Device Management Options................................................................................................ 2-82-4. Port Management Options .................................................................................................... 2-9

    3-1. System Information Parameters ............................................................................................. 3-23-2. Manager List Parameters........................................................................................................ 3-43-3. Access Parameters................................................................................................................. 3-53-4. Device Parameters ................................................................................................................ 3-73-5. Interface Parameters.............................................................................................................. 3-93-6. Link Parameters................................................................................................................... 3-113-7. Channel Parameters ............................................................................................................ 3-13

    4-1. Alarm Buffer List Parameters.................................................................................................. 4-24-2. Device Alarms Parameters..................................................................................................... 4-4

    4-3. Mask Channel Alarm Parameters ........................................................................................... 4-54-4. Lines Status Parameters ......................................................................................................... 4-7

    4-5. Local Loopback Test Parameters............................................................................................ 4-84-6. Link Alarms Parameters ......................................................................................................... 4-94-7. Channel Alarms Parameters................................................................................................. 4-104-8. Link Loopback Test Parameters ........................................................................................... 4-124-9. Channel Loopback Test Parameters..................................................................................... 4-14

  • 7/31/2019 Manual Optimux 4E1L

    7/50

    Overview 1-1

    Chapter 1

    Introduction

    1.1 Overview

    General

    Optimux-4E1 and Optimux-4T1 are second-order multiplexers that combine fourE1/T1 tributary data streams into a single fiber optic link. Optimux-4E1L andOptimux-4T1L are low-cost versions of the standard standalone units.

    The fiber optic interface provides a secure link in hazardous or hostileenvironments, increases the maximum connection range, and achieves immunityagainst electrical interference and protection against the harmful effects of groundloops.

    Features

    The main features of the multiplexers are:

    Four E1/T1 multiplexed channels over a single fiber optic link

    A pair of Optimux-4E1/T1 units offers simple connectivity for four E1/T1channels at distances of up to 120 km (74.5 miles)

    Operate with multimode or single mode fiber; and single mode over singlefiber in the WDM module

    Transmit each of the E1/T1 channels independently, so that each E1/T1channel can have its own clock source

    To facilitate system diagnostics, the units feature LED status indicators, AISalarm generation, recognition, and dry contact closure upon link failure.

    Setup, control and diagnostics can be performed via a supervisory port usingan ASCII terminal

    Conform to ITU G.703, G.823, G.824 and G.955

    Compact 1U high size.

  • 7/31/2019 Manual Optimux 4E1L

    8/50

    Chapter 1 Introduction RADview Optimux-4E1/T1 Users Manual

    1-2 Functional Description

    Application

    The following diagram illustrates a typical application of the Optimux-4T1L unit:

    Figure 1-1 Typical Application

    1.2 Functional Description

    Test and Diagnostic Capabilities

    Optimux-4E1/T1 have comprehensive test and diagnostics capabilities that includelocal and remote loopbacks on the fiber optic link interface and on each tributarylink. The loopbacks activation on the remote device is performed by sending a

    special test sequence through the fiber optic link. An automatic self-test on power-up further enhances maintenance.

    Fiber Optic Link

    The fiber optic interface is used to provide a secure link in hazardous or hostileenvironments, increase the maximum connection range, and achieve immunityagainst electrical interference and protection against the harmful effects of groundloops.

    The fiber optic interface complies with the requirements of ITU-T Rec. G.956, anduses a proprietary signaling format that ensures optimum performance. Tooptimally meet a wide range of system requirements, the fiber optic interface canbe ordered for operation over 62.5/125 micron multi-mode fibers (typicalattenuation 3.5 dB/km at 850 nm and 1.5 dB/km at 1310 nm), as well as over low-loss 9/125-micron single-mode fibers (typical attenuation 0.4 dB/km at 1300 nm,and 0.25 dB/km at 1550 nm). Most of the options can be ordered with ST, SC, orFC/PC connectors. In addition, 9/125-micron single mode over a single fiber is alsoavailable (with SC connectors only).

    The SF3 option uses an SC/APC connector. The FO cable connected to it musttherefore be of the same type.

    Note

  • 7/31/2019 Manual Optimux 4E1L

    9/50

    RADview Optimux-4E1/T1 Users Manual Chapter 1 Introduction

    Functional Description 1-3

    Tributary Interface Characteristics

    The Optimux-4E1/T1 tributary interfaces meet the requirements of ITU-T Rec.G.703. Each tributary port has a 100 balanced line interface terminated in anRJ-45 eight-pin connector.

    Line coding is B8ZS or AMI. The nominal balanced interface transmit level is

    3.0V. The line attenuation is up to 12 dB, and each E1/T1 signal is processed byan adaptive equalizer that compensates for various cable lengths to ensure optimalperformance. Phase Locked Loops (PLL) are used to recover the clock signals, andthe resulting jitter performance complies with the requirements of ITU-T Rec.G.824.

    Each tributary interface has its own set of indicators that show the current state ofthe tributary link. The user can disable the alarm indications generated by unusedinterfaces (via internal switches, seesection 2.5). AIS data streams are transmittedinstead of failed or unconnected tributary data streams.

    Alarms and Alarm Indications

    Optimux-4E1/T1 can detect the following alarm conditions on each E1/T1 andfiber optic interface:

    Loss of input signal

    Loss of frame synchronization

    Reception of alarm indication (AIS) signal, which consists of a continuoussequence of 1s.

    When AIS is received, loss of frame synchronization occurs. However, in this casethe alarm indicating loss of frame synchronization is suppressed.

    When not all the tributaries are in use, the user can disable the alarm indicationsrelated to the unused tributaries.

    The response to alarm conditions is as follows:

    AIS is transmitted on each tributary output in the following cases:

    Loss of fiber optic input signal is detected

    AIS is received on the fiber optic input

    Fiber optic frame synchronization is lost.

    An AIS signal is sent on a tributary instead of the tributary data stream throughthe fiber optic link in the following cases:

    Loss of tributary input signal is detected

    AIS is received on the tributary input

    Tributary frame synchronization is lost.

    Front panel indicators display each alarm condition. In addition, a dedicatedconnector is used to provide major and minor alarm indications, by means of drycontacts.

    Note

  • 7/31/2019 Manual Optimux 4E1L

    10/50

    Chapter 1 Introduction RADview Optimux-4E1/T1 Users Manual

    1-4 Functional Description

    The major alarm is activated in the following cases:

    Optimux-4E1/T1 is not powered, or power supply failure

    Loss of fiber optic input signal, or loss of fiber optic frame synchronization

    Loss of tributary input signals, or loss of frame synchronization.

    The minor alarm is activated in the following cases:

    Reception of AIS signal on the fiber optic input

    Reception of AIS signal on tributary inputs.

    An optional 5 VDC/100 mA pin is available for the user to be able to operate theexternal alarm system (small lamp, buzzer, etc.).

    An additional (optional) input alarm signal (EXTERNAL ALARM) allows the user toinform Optimux-4E1/T1 that the user system is reporting alarm status. This inputsignal supports RS-232 levels.

  • 7/31/2019 Manual Optimux 4E1L

    11/50

    Configuring for Management 2-1

    Chapter 2

    Installation and SetupThis chapter provides instructions for configuring and connecting the Optimux-4E1/Optimux-4T1 or the Optimux-4E1L/Optimux-4T1L units for use withRADview.

    2.1 Configuring for Management

    All units Optimux-4E1/4T1 or Optimux-4E1L/4T1L must be configured via theterminal for management before connecting to the network.

    To configure a unit for management:

    1. Follow the path: Main Menu > Configuration > System Configuration >Management > Device Info.

    2. Complete the details for the System Contact, System Name, and SystemLocation.

    To define a system contact person, choose System Contact and then enterthe name, phone and/or other details you want to save in this field.

    To specify a name to identify the device, choose System Name and thenenter the name. It is easier to identify the device by a name than by its IPaddress.

    To specify a system location, choose System Location and then enter thelocation of the unit.

    3. From the Management Menu selectHost IP.

    The Host IP List menu (Figure 2-1) is displayed.

    OP-4E1

    Host IP List

    1. IP Address ... (172.17.161.93)

    2. IP Mask ... (255.255.255.0)

    >Please select item

    ESC-prev. menu; !-main menu; &-exit 1 user(s)

    Figure 2-1. Host IP List Menu

    4. To set the IP address of the unit, selectIP Address and then enter the IPaddress.

    5. To set the IP Mask, selectIP Mask and then enter the IP mask.

  • 7/31/2019 Manual Optimux 4E1L

    12/50

    Chapter 2 Installation and Setup RADview Optimux-4E1/Optimux-4T1 Users Manual

    2-2 Configuring for Management

    6. To set the default gateway, go back to the Host IP menu, selectDefaultGateway and then enter the IP address of the gateway.

    7. From the Host IP menu, choose Read Community and then specify a string ofeight characters.This field is used by SNMP.

    8. From the Host IP menu, choose Write Community and then specify a string ofeight characters. This field is used by SNMP.

    9. From the Host IP menu, choose Trap Community and then specify a string ofeight characters.This field is used by SNMP.

    Setting up the Manager List

    By default, any remote management terminal is allowed to change theconfiguration of the Optimux device. You may enhance the security of the site bylimiting remote management to specific management terminals or nodes. TheManager List lists the network nodes from which management may take place.

    To define the manager list:

    1. From the Management menu selectManager List.The Manager List screen (Figure 2-2) is displayed.

    OP-4E1

    Manager List

    mngNum mngIP mngMask

    1 0.0.0.0 NO

    | 2 0.0.0.0 NO

    | 3 0.0.0.0 NO

    v 4 0.0.0.0 NO

    5 0.0.0.0 NO

    1. Change cell ... (0.0.0.0)

    >

    ESC-prev. menu; !-main menu; &-exit 1 user(s)

    Figure 2-2. Manager List Screen

    2. The list contains 10 entries. Press D to move down the list; press U to move upthe list. Press L to select the previous field; press R to select the next field.

    3. To change the value of a field, select the field (it will appear highlighted), thenchoose Change Cell and then enter the new value.

    When the mngMask field is set toYes, a trap is sent to this agent.

    Setting the Management Access

    To set the management access:

    1. From the Management menu, choose Manager Access.

    The Manager Access menu (Figure 2-3) is displayed.

  • 7/31/2019 Manual Optimux 4E1L

    13/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 2 Installation and Setup

    Connecting Optimux-4E1/Optimux-4T1 for Management 2-3

    OP-4E1

    Manager Access

    1. TELNET access >

    2. SNMP access >

    3. Web access >

    4. Web Trace Refresh (seconds)[1-255] ... (30)

    >

    Please select item

    ESC-prev. menu; !-main menu; &-exit 1 user(s)

    Figure 2-3. Manager Access Menu

    2. SelectSNMP to use for management access:

    OP-4E1

    SNMP access

    1. Disable

    2. Enable

    3. Managers only

    >

    Please select item

    ESC-prev. menu; !-main menu; &-exit 1 user(s)

    Figure 2-4. Telnet Menu

    3. Choose Enable to enable this access mode; choose Disable to disable thisaccess mode. Choose Managers only to provide management access only tothose users whose IP addresses appear in the Manager List.

    2.2 Connecting Optimux-4E1/Optimux-4T1 forManagement

    Connect the RADview management station to a local Optimux-4E1/4T1 by adirect Ethernet management link. Use the MNG connector on the rear panel ofthe Optimux-4E1/4T1.

    Figure 2-5. Management to Optimux-4E1 or Optimux-4T1 via Ethernet

  • 7/31/2019 Manual Optimux 4E1L

    14/50

    Chapter 2 Installation and Setup RADview Optimux-4E1/Optimux-4T1 Users Manual

    2-4 Configuring Optimux-4E1L/Optimux-4T1L Control Port for Management

    2.3 Configuring Optimux-4E1L/Optimux-4T1L ControlPort for Management

    The RADview management station is connected to an Optimux-4E1L or Optimux-4T1L via an MBE (Ethernet Elementary Bridge), or any other device that supportsPPP, to convert Ethernet data to PPP (Point to Point Protocol). The CONTROL port(DB-9) on the Optimux-4E1L/4T1L rear panel is used to connect to the MBE.

    The Optimux-4E1L/4T1L control port has two modes; either to connect an ASCIIterminal directly to the device, or PPP for management purposes.

    Using an ASCII terminal or PC using terminal emulation, configure the MBE protocolto PPP. Set the following parameters: Baud Rate=115,200 bps, Stop Bits=1,parity=none, data bits=8, flow control=none. See the MBE Installation andOperation Manual for details.

    Figure 2-6shows the LAN management of Optimux-4E1L/4T1L via MBE, over PPP.

    Figure 2-6. Management-to-MBE-to-Optimux-4E1L/4T1L Connection

    Configuring the Control Port for PPP mode

    To configure the control port:

    1. Configure the Management PC COM port to 115,200 bps.

    2. Follow the path: Main Menu > Configuration > System Configuration >Control Port

    3. From the Control Port menu, selectMode.

    The device switches from the default Terminal mode to PPP. The terminalscreen goes blank, or random characters are displayed, this is normal.The device is ready to operate with RADview.

    PPP activates only at 115,200 bps baud rate. Optimux-4E1L/4T1L automaticallyconverts to a baud rate of 115,200 bps when in PPP mode.PPP

    Returning the Control Port to Terminal Mode

    Once you have finished working with RADview return the Optimux-4E1L/4T1Lcontrol port from PPP to terminal mode.

    Note

    Note

  • 7/31/2019 Manual Optimux 4E1L

    15/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 2 Installation and Setup

    Using the Graphical User Interface 2-5

    When in PPP mode the control port is used as a management port. A terminalscreen will be blank, or display random characters.

    To return the control port to terminal mode:

    1. Configure the PC COM port to 115,200 bps.

    2. Press the key on your keyboard.

    3. Type monitor in the > prompt in the terminal.

    4. Press the key on your keyboard again.

    The device is now in terminal mode.

    2.4 Using the Graphical User Interface

    The RADview Optimux-4E1/Optimux-4T1 window provides a dynamicallyupdated graphical representation of the Optimux-4E1/Optimux-4T1 devices atboth ends of the link, allowing you to monitor and manageOptimux-4E1/Optimux-4T1 operations (see Figure 2-7).

    The window includes:

    Link interfaces

    Channel interfaces

    LED operational and communication status indicators for each interface(LINK, CH1-CH4)

    LED status indicators for each device (PWR, TST)

    When working with Optimux-4E1/4T1 new look vs. Optimux-4E1L/4T1L, theremote modem is displayed as old look.When the local modem is not new look, then the remote modem is displayed asthe same as the local device.

    Note

    Note

  • 7/31/2019 Manual Optimux 4E1L

    16/50

    Chapter 2 Installation and Setup RADview Optimux-4E1/Optimux-4T1 Users Manual

    2-6 Using the Graphical User Interface

    Figure 2-7. RADview Window

    Menu Bar

    The menu bar includes the following pull-down menus:

    Configuration

    Fault

    Diagnostics

    Options

    Help

    The Menu content varies depending on what you select in the RADview window;the entire system, one of the Optimux devices, or an interface. A blue borderindicates a selected item.

    Status Bar

    The status bar indicates if RADview is ready or currently polling the device.

  • 7/31/2019 Manual Optimux 4E1L

    17/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 2 Installation and Setup

    System Level Operations 2-7

    LEDs

    The front panel includes a series of LED indicators that show the current operatingstatus of the unit. Table 2-1lists and describes the indicators.

    Table 2-1. Optimux-4E1/Optimux-4T1 LEDs

    Name Function Location

    PWR (green) ON Power supply is ON

    ON (red) Power supply fault

    Front panel

    TST (yellow) ON Test is active on one of the devices ports. Front panel

    LOSS LINK (red) ON Loss exists on the link Front panel

    AIS LINK (red) ON AIS alarm exists on the link Front panel

    LOSS CHs 1-4 (red) ON Loss exists on the channel Front panel

    AIS CHs 1-4 (red) ON AIS alarm exists on the channel Front panel

    2.5 System Level Operations

    Table 2-2lists the management tasks that are available when you select the entiresystem.

    Table 2-2. System Management Options

    Tasks Configuration

    Dialog Box and ParameterLocation

    Path

    Viewing and SettingSystem Information System Information Dialog Box ConfigurationSystem Info

    Polling the Agents Polling the Agents ConfigurationPoll Agent

    Tasks Fault Dialog Box and ParameterLocation

    Path

    Displaying theAlarm Buffer List

    Alarm Buffer List Dialog Box(refer to Displaying the AlarmBuffer List in Chapter2)

    FaultHistory LogList...

    Clearing the Alarm

    Buffer

    Clearing the Alarm Buffer in

    Chapter2

    Fault

    History LogClear

  • 7/31/2019 Manual Optimux 4E1L

    18/50

    Chapter 2 Installation and Setup RADview Optimux-4E1/Optimux-4T1 Users Manual

    2-8 Device Level Operations

    Tasks Options Dialog Box and ParameterLocation

    Path

    Configuring theManager List

    Manager List Dialog Box (refer toConfiguring the Manager List inChapter3)

    OptionsManager List...

    Configuring Access

    Restrictions

    Access Dialog Box (refer to

    Configuring Access Restrictions inChapter3)

    Options

    Access...

    ConfiguringAutomatic Polling

    Configuring Automatic Polling inChapter3)

    OptionsPolling

    2.6 Device Level Operations

    Table 2-3lists the management tasks that are available when you select one of theOptimux devices.

    Table 2-3. Device Management Options

    Tasks Configuration

    Dialog Box and ParameterLocation

    Path

    Configuring DeviceParameters

    Local Parameters Dialog Boxand Remote Parameters DialogBox (refer to Configuring DeviceParameters in Chapter3)

    ConfigurationParameters

    Viewing InterfaceInformation

    Local Interfaces Dialog BoxandRemote Interfaces Dialog Box

    (refer to Viewing InterfaceInformation in Chapter3)

    ConfigurationInterfaces

    Resetting theHardware

    Resetting the Hardware inChapter3

    ConfigurationResetHW

    Resetting theConfiguration

    Resetting the Configuration inChapter3

    ConfigurationResetConfig

    Tasks Fault Dialog Box and ParameterLocation

    Path

    Displaying the Alarms Device Alarms Dialog Box(refer to Displaying the Alarmsin Chapter2)

    FaultAlarms...

    Configuring ChannelAlarm Masks

    Mask Channel Alarm DialogBox (refer to ConfiguringChannel Alarm Masks inChapter2)

    FaultMask Channel Alarm...

  • 7/31/2019 Manual Optimux 4E1L

    19/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 2 Installation and Setup

    Port Level Operations 2-9

    Tasks Diagnostics Dialog Box and ParameterLocation

    Path

    Viewing the LinesStatus

    Local Lines Status Dialog Boxand Remote Lines Status DialogBox (refer to Viewing the LinesStatus in Chapter2)

    DiagnosticsLines Status...

    Running a LoopbackTest

    Local Loopback Test Dialog Box(refer to Running a LoopbackTest on a Device in Chapter2)

    DiagnosticsLoopback Test...

    2.7 Port Level Operations

    Table 2-4 lists the management tasks that are available when you select a port.

    Table 2-4. Port Management Options

    Tasks Configuration

    Dialog Box and ParameterLocation

    Path

    Configuring LinkParameters

    Local Link Parameters DialogBox andRemote Link ParametersDialog Box (refer to ConfiguringLink Parameters

    ConfigurationParameters

    Configuring ChannelParameters

    Local Channel ParametersDialog Box andRemote ChannelParameters Dialog Box (refer toConfiguring Channel Parameters)

    ConfigurationParameters

    Tasks Fault Dialog Box and ParameterLocation

    Path

    Displaying the Alarmsfor a Link

    Link Alarms Dialog Box (refer toDisplaying the Alarms for a Link)

    FaultAlarms

    Displaying the Alarmsfor a Channel

    Channel Alarms Dialog Box(refer to Displaying the Alarmsfor a Channel)

    FaultAlarms

    Tasks Diagnostics Dialog Box and ParameterLocation

    Path

    Running a Loopback

    Test on a Link

    Link Loopback Test Dialog Box

    (refer to Running a LoopbackTest on a Link)

    Diagnostics

    Loopback Test

    Tasks Configuration

    Dialog Box and ParameterLocation

    Path

    Running a LoopbackTest on a Channel

    Local Channel Loopback TestDialog Box and Remote ChannelLoopback Test Dialog Box (referto Running a Loopback Test on aChannel)

    Diagnostics Loopback Test

  • 7/31/2019 Manual Optimux 4E1L

    20/50

    Chapter 2 Installation and Setup RADview Optimux-4E1/Optimux-4T1 Users Manual

    2-10 Port Level Operations

  • 7/31/2019 Manual Optimux 4E1L

    21/50

    System Level Configuration Menu 3-1

    Chapter 3

    Configuration ManagementThe chapter describes the Optimux-4E1/Optimux-4T1 configuration managementat the system, device, and port levels.

    3.1 System Level Configuration Menu

    The Configuration menu provides access to system level configuration.

    Figure 3-1. System Level Configuration Menu

    Viewing and Setting System Information

    The System Info command enables you to view and set physical informationabout the Optimux-4E1/Optimux-4T1.

    To view and set system information:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the system.

    2. SelectConfiguration > System Info...

    3. Configure the parameters as needed.

    4. Click .

  • 7/31/2019 Manual Optimux 4E1L

    22/50

    Chapter 3 Configuration Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    3-2 System Level Configuration Menu

    Figure 3-2. System Information Dialog Box

    Table 3-1. System Information Parameters

    Parameter Possible Values / Remarks

    Description OP-4E1 or OP-4T1, and the hardware and software version numbers

    Object ID ID of the system

    Name System name

    Contact Contact information

    Location System location

    System Up Time Format: H hours, M minutes, S seconds

    [Set] Click to send new values to the agent

    [Cancel] Click to close the System Information dialog box

    [Refresh] Click to refresh the data in the System Information dialog box

  • 7/31/2019 Manual Optimux 4E1L

    23/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 3 Configuration Management

    System Level Options Menu 3-3

    Polling the Agents

    The Poll Agent command causes RADview-TDM to poll the agents on the localand remote devices. RADview-TDM polls the agents to get the current status of theOptimux devices.

    If you enable automatic polling, RADview-TDM automatically polls the agentsevery sixty minutes. You can also poll the agents manually with the Poll Agentcommand. If you disable automatic polling, you must use the Poll Agentcommand to poll the agents. For more information about configuring automaticpolling, see Configuring Automatic Polling on page 3-6.

    To poll the agents:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the system.

    2. SelectConfiguration > Poll Agent.

    The device immediately polls the agents.

    3.2 System Level Options Menu

    The Options menu enables you to configure system options.

    Figure 3-3. System Level Options Menu

    Configuring the Manager List

    The Manager List command enables you to view and configure the Manager List.The Manager List is a list of IP addresses. You can use the Manager List to:

    Specify the NMS stations that unmask SNMP traps from the Optimux devices

    Specify the stations that have Telnet and Web access to the Optimux devices

    For more information about how to use the Manager List to restrict Telnet andWeb access, see Configuring Access Restrictions on page 3-5.

    To configure the Manager List:1. In the RADview Optimux-4E1/Optimux-4T1 window, select the system.

    2. SelectOptions > Manager List...

    3. Change the values of the IP Address and Mask Traps fields for each manager,as needed.

    4. Click .

  • 7/31/2019 Manual Optimux 4E1L

    24/50

    Chapter 3 Configuration Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    3-4 System Level Options Menu

    Figure 3-4. Manager List Dialog Box

    Table 3-2. Manager List ParametersParameter Possible Values / Remarks

    Manager ID 1..10

    IP Address An IP address of 0.0.0.0 means that there is no manager

    Mask Traps Checked: mask traps to this manager. Unchecked: do not mask traps to this manager

    [Set] Click to send new values to the agent

    [Cancel] Click to close the Manager List dialog box

    [Refresh] Click to refresh the data in the Manager List dialog box

  • 7/31/2019 Manual Optimux 4E1L

    25/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 3 Configuration Management

    System Level Options Menu 3-5

    Configuring Access Restrictions

    TheAccess command enables you to configure access restrictions for the local andremote devices. Access restrictions control whether a remote station can access thedevices with Telnet and through the Web. You can configure the following accesslevels:

    Enable access to the device from all stations

    Disable access to the device from all stations

    Enable access to the device only from stations that are on the Manager List. Formore information about the Manager List, see Configuring the Manager Listonpage 3-3.

    To configure access restrictions:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the system.

    2. SelectOptions >Access...

    3. Change the values of the Telnet Access and Web Access fields, as needed.4. Click .

    Figure 3-5. Access Dialog Box

    Table 3-3. Access Parameters

    Parameter Possible Values / Remarks

    Telnet Access Disable, Enable, Managers Only

    Web Access Disable, Enable, Managers Only

    [Set] Click to send new values to the agent

    [Cancel] Click to close the Access dialog box

    [Refresh] Click to refresh the data in the Access dialog box

  • 7/31/2019 Manual Optimux 4E1L

    26/50

    Chapter 3 Configuration Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    3-6 Device Level Configuration Menu

    Configuring Automatic Polling

    The Polling command allows you to enable or disable automatic polling.RADview-TDM polls the agents on the local and remote devices to get the currentstatus of the devices. If you enable automatic polling, RADview-TDM polls theagents every sixty minutes. If you disable automatic polling, you must use the PollAgent command to poll the agents manually. For more information about the Poll

    Agent command, see Polling the Agents on page 3-3.

    To configure automatic polling:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the system.

    2. Open the Options menu.

    3. Check or uncheck Polling, as needed.

    3.3 Device Level Configuration Menu

    The Configuration menu provides device level configuration information.

    Figure 3-6. Device Level Configuration Menu

    Configuring Device Parameters

    The Parameters command enables you to view and set parameters of the localand remote devices.

    To configure device parameters:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select a device.

    2. SelectConfiguration > Parameters...

    3. Configure the parameters as needed.

    4. Click .

  • 7/31/2019 Manual Optimux 4E1L

    27/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 3 Configuration Management

    Device Level Configuration Menu 3-7

    Figure 3-7. Local Parameters Dialog Box

    Figure 3-8. Remote Parameters Dialog Box

    Table 3-4. Device Parameters

    Parameter Possible Values / Remarks

    HW Version Hardware version number

    SW Version Software version number

    [Done] Click to close the Local/Remote dialog box

    [Refresh] Click to refresh the data in the Parameters dialog box

  • 7/31/2019 Manual Optimux 4E1L

    28/50

    Chapter 3 Configuration Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    3-8 Device Level Configuration Menu

    Viewing Interface Information

    The Interfaces command enables you to view information about the links andchannels of a device.

    To view interface information:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select a device.2. SelectConfiguration > Interfaces...

    Figure 3-9. Local Interfaces Dialog Box

    Figure 3-10. Remote Interfaces Dialog Box

  • 7/31/2019 Manual Optimux 4E1L

    29/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 3 Configuration Management

    Device Level Configuration Menu 3-9

    Table 3-5. Interface Parameters

    Parameter Possible Values / Remarks

    Index Index number of the port

    Type Type of the port

    Name & Description Name and description of the interface

    Speed Speed of the interface in bits per second

    [Done] Click to close the Interfaces dialog box

    [Refresh] Click to refresh the data in the Interfaces dialog box

    Resetting the Hardware

    The Reset HWcommand enables you to reset the Agents hardware.

    To reset the hardware:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the device.

    2. SelectConfiguration > Reset > HW.

    3. Click .

    The agents hardware is reset.

    Resetting the Configuration

    The Reset Config command enables you to reset the Agents configuration.

    To reset the configuration:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the device.

    2. SelectConfiguration > Reset > Config.

    3. Click .

    The agents configuration is reset.

  • 7/31/2019 Manual Optimux 4E1L

    30/50

    Chapter 3 Configuration Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    3-10 Port Level Configuration Menu

    3.4 Port Level Configuration Menu

    The Configuration menu provides access to port level configuration. You canconfigure parameters for the following types of ports:

    Link Channel

    Figure 3-11. Port Level Configuration Menu

    Configuring Link Parameters

    When you select a link port, the Parameters command enables you to configure

    parameters for the link. To configure link parameters:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select a link port.

    2. SelectConfiguration > Parameters...

    3. Configure the parameters as needed.

    4. Click .

    Figure 3-12. Local Link Parameters Dialog Box

  • 7/31/2019 Manual Optimux 4E1L

    31/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 3 Configuration Management

    Port Level Configuration Menu 3-11

    Figure 3-13. Remote Link Parameters Dialog Box

    Table 3-6. Link Parameters

    Parameter Possible Values / Remarks

    Line Coding HDB3, Proprietary

    Interface Type Copper

    Connector Type SC, ST, FC, BNC, SF1, SF2, SF3

    User Name Any string

    Last Change Format: H hours, M minutes, S seconds

    [Set] Click to send the new configuration to the agent

    [Cancel] Click to close the Link Parameters dialog box

    [Refresh] Click to update the data in the Link Parameters dialog box

  • 7/31/2019 Manual Optimux 4E1L

    32/50

    Chapter 3 Configuration Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    3-12 Port Level Configuration Menu

    Configuring Channel Parameters

    When you select a channel port, the Parameters command enables you toconfigure parameters for the channel.

    To configure channel parameters:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select a channel port.

    2. SelectConfiguration > Parameters...

    3. Configure the parameters as needed.

    4. Click .

    Figure 3-14. Local Channel Parameters Dialog Box

    Figure 3-15. Remote Channel Parameters Dialog Box

  • 7/31/2019 Manual Optimux 4E1L

    33/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 3 Configuration Management

    Port Level Configuration Menu 3-13

    Table 3-7. Channel Parameters

    Parameter Possible Values / Remarks

    Line Coding HDB3 (E1 only), B8ZS (T1 only), AMI

    Line Length (ft) (T1 only) 0-133, 134-266, 267-399, 400-599, 600-655

    Interface Type (E1 only) Balanced, UnbalancedUser Name Any string

    Last Change Format: H hours, M minutes, S seconds

    [Set] Click to send the new configuration to the agent

    [Cancel] Click to close the Channel Parameters dialog box

    [Refresh] Click to update the data in the Channel Parameters dialog box

  • 7/31/2019 Manual Optimux 4E1L

    34/50

    Chapter 3 Configuration Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    3-14 Port Level Configuration Menu

  • 7/31/2019 Manual Optimux 4E1L

    35/50

    System Level Fault Management Fault Menu 4-1

    Chapter 4

    Fault ManagementThis chapter describes Optimux-4E1/Optimux-4T1 fault management at thesystem, device, and port levels.

    4.1 System Level Fault Management Fault Menu

    The Fault menu provides access to the system alarm options. You can view alarmseverity as well as clear alarms.

    Figure 4-1. System Level Fault Menu

    Displaying the Alarm Buffer List

    The History Log > List command enables you to view the alarm buffer thatcontains the recorded alarms of the local and remote devices.

    To display the alarm buffer list:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the system.2. SelectFault > History Log > List...

  • 7/31/2019 Manual Optimux 4E1L

    36/50

    Chapter 4 Fault Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    4-2 System Level Fault Management Fault Menu

    Figure 4-2. Alarm Buffer List Dialog Box

    Table 4-1. Alarm Buffer List Parameters

    Parameter Possible Values / Remarks

    Code Alarm code

    Description Description of the alarm

    Location Local, Remote

    Port Port reporting the alarm

    State Off, Event, Minor, Major

    Date Date of the alarm in the format: YYYY-MM-DD

    Time Time of the alarm in the format: HH:MM:SS

    [Done] Click to close the Alarm Buffer List

    [Print...] Click to print the Alarm Buffer List

    [Save To File...] Click to save the Alarm Buffer List to a file. The Save dialog boxappears. In the File Name field, enter the name of the file. In the File of type field, selectAcrobat (*pdf) or HTML (*.htm). Click Save

    [Refresh] Click to update the Alarm Buffer List

  • 7/31/2019 Manual Optimux 4E1L

    37/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 4 Fault Management

    Device Level Fault Management Fault Menu 4-3

    Clearing the Alarm Buffer

    The History Log > Clear command enables you to clear all entries in the alarmbuffer.

    To clear the alarm buffer:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the system.2. SelectFault > History Log > Clear.

    The next time you view the Alarm Buffer List, only alarms that occur afterthe Clear operation appear in the list.

    4.2 Device Level Fault Management Fault Menu

    The Fault menu provides access to the device alarm options. You can view alarm

    severity as well as mask alarms.

    Figure 4-3. Device Level Fault Menu

    Displaying the Alarms

    TheAlarms command enables you to view the active alarms for a device.

    To display the alarms for a device:1. In the RADview Optimux-4E1/Optimux-4T1 window, select the device.

    2. SelectFault >Alarms

  • 7/31/2019 Manual Optimux 4E1L

    38/50

    Chapter 4 Fault Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    4-4 Device Level Fault Management Fault Menu

    Figure 4-4. Device Alarms Dialog Box

    Table 4-2. Device Alarms Parameters

    Parameter Possible Values / Remarks

    Code Alarm codeDescription Description of the alarm

    Severity Major, Minor

    [Done] Click to close the Alarms dialog box

    [Print...] Click to print the Alarms

    [Save To File...] Click to save the Alarms. The Save dialog box appears. In the FileName field, enter the name of the file. In the File of type field, selectAcrobat (*pdf) orHTML (*.htm). Click Save

    [Refresh] Click to update the Alarms

  • 7/31/2019 Manual Optimux 4E1L

    39/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 4 Fault Management

    Device Level Fault Management Fault Menu 4-5

    Configuring Channel Alarm Masks

    The Mask Channel Alarm command enables you to configure channel alarmmasks for a device. When you set a channel alarm mask, the channel does notcause an alarm.

    To configure channel alarm masks for a device:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the device.

    2. SelectFault > Mask Channel Alarm

    3. Check and uncheck the SW Alarm Mask check boxes as needed.

    4. Click .

    When there is a Hardware Alarm Mask on a channel, you cannot clear the alarmmask. TheSW Alarm Maskcheckbox for the channel is disabled.

    Figure 4-5. Mask Channel Alarm Dialog Box

    Table 4-3. Mask Channel Alarm Parameters

    Parameter Possible Values / Remarks

    HW Mask(CH1-CH4)

    Hardware alarm masks (read-only)

    SW Alarm Mask(CH1-CH4)

    Software alarm masks

    [Set] Click to send new values to the agent

    [Cancel] Click to close the Mask Channel Alarm dialog.

    [Refresh] Click to update the alarm masks

    Note

  • 7/31/2019 Manual Optimux 4E1L

    40/50

    Chapter 4 Fault Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    4-6 Device Level Fault Management Diagnostics Menu

    4.3 Device Level Fault Management Diagnostics Menu

    The Diagnostics menu provides access to the device level diagnostic test options.

    Figure 4-6. Device Level Diagnostics Menu

    Viewing the Lines Status

    The Lines Status command enables you to view the current operational andcommunication status of all the channels and links of a device.

    To view the lines status:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the device.2. SelectDiagnostics > Lines Status...

    Figure 4-7. Local Lines Status Dialog Box

  • 7/31/2019 Manual Optimux 4E1L

    41/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 4 Fault Management

    Device Level Fault Management Diagnostics Menu 4-7

    Figure 4-8. Remote Lines Status Dialog Box

    Table 4-4. Lines Status Parameters

    Parameter Possible Values / Remarks

    Rcv AIS Alarm Indication Signal was received at the link/channel

    Loss of Signal No input signal was received at the interface.

    Loopback State Indicates that a loopback test is in progress in the link/channel

    Other Failure Indicates a failure (other than those listed above) in the link/channel

    [Done] Click to close the Device Loopback Test dialog box

    [Refresh] Click to update the alarm masks

    Running a Loopback Test on a Device

    The Loopback Test command enables you to:

    View all loopback tests that are currently running on both the local device andthe remote device

    Run a remote loopback test on all channels of the remote device

    You cannot run a loopback test if a loopback test is already running on the local orremote device.

    To view all loopback tests that are currently running on both devices:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the device.2. SelectDiagnostics > Loopback Test...

    To run a remote loopback test on all channels of the remote device:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the device.

    2. SelectDiagnostics > Loopback Test...

    3. Check the Group Remote Loop box.

    4. ClickApply.

  • 7/31/2019 Manual Optimux 4E1L

    42/50

  • 7/31/2019 Manual Optimux 4E1L

    43/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 4 Fault Management

    Port Level Fault Management Fault Menu 4-9

    Displaying the Alarms for a Link

    When you select a link port, theAlarms command enables you to view the activealarms for the link.

    To display the alarms for a link:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select a link port.

    2. SelectFault >Alarms

    Figure 4-11. Link Alarms Dialog Box

    Table 4-6. Link Alarms Parameters

    Parameter Possible Values / Remarks

    Code Alarm code

    Description Description of the alarm

    Severity Major, Minor

    [Done] Click to close the Alarms dialog box

    [Print...] Click to print the Alarms

    [Save To File...] Click to save the Alarms. The Save dialog box appears. In the File Namefield, enter the name of the file. In the File of type field, selectAcrobat (*pdf) orHTML(*.htm). Click Save

    [Refresh] Click to update the Alarms

  • 7/31/2019 Manual Optimux 4E1L

    44/50

    Chapter 4 Fault Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    4-10 Port Level Fault Management Fault Menu

    Displaying the Alarms for a Channel

    When you select a channel port, theAlarms command enables you to view theactive alarms for the channel.

    To display the alarms for a channel:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select a channel port.

    2. SelectFault >Alarms

    Figure 4-12. Channel Alarms Dialog Box

    Table 4-7. Channel Alarms Parameters

    Parameter Possible Values / Remarks

    Code Alarm code

    Description Description of the alarm

    Severity Major, Minor

    [Done] Click to close the Alarms dialog box

    [Print...] Click to print the Alarms

    [Save To File...] Click to save the Alarms. The Save dialog box appears. In the File Namefield, enter the name of the file. In the File of type field, selectAcrobat (*pdf) orHTML(*.htm). Click Save

    [Refresh] Click to update the Alarms

  • 7/31/2019 Manual Optimux 4E1L

    45/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 4 Fault Management

    Port Level Fault Management Diagnostics Menu 4-11

    4.5 Port Level Fault Management Diagnostics Menu

    The Diagnostics menu provides access to the port level diagnostic test options. Youcan run loopback tests for the following types of ports:

    Link

    Channel

    Figure 4-13. Port Level Diagnostics Menu

    Running a Loopback Test on a Link

    The Loopback Test command enables you to:

    View all loopback tests that are currently running on the local and remote

    devices Run a loopback test on a link.

    You cannot run:

    A loopback test on a channel if a loopback test is already running on a link

    A loopback test on a link if a loopback test is already running on a channel

    A remote loopback test on a channel if a remote loopback test is alreadyrunning at the opposite end of the channel.

    To view all loopback tests that are currently running on both devices:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select a device.

    2. SelectDiagnostics > Loopback Test...

    To run a loopback test on a link:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select a link port.

    2. SelectDiagnostics > Loopback Test...

    3. In the Loopback Config drop down list, select the type of loopback test youwant to run.

    4. If you want to run a link local loopback test, then either:

    In the LLB Duration box, select the duration of the test

    OR Check the Forever checkbox

    The LLB Duration box and the Forever checkbox are only available ifLink LocalLoopbackis selected in the Loopback Config drop down list.

    5. ClickApply.

    Note

  • 7/31/2019 Manual Optimux 4E1L

    46/50

    Chapter 4 Fault Management RADview Optimux-4E1/Optimux-4T1 Users Manual

    4-12 Port Level Fault Management Diagnostics Menu

    Figure 4-14. Link Loopback Test Dialog Box

    Table 4-8. Link Loopback Test Parameters

    Parameter Possible Values / Remarks

    Local Unit The links and channels of the local device

    Remote Unit The links and channels of the remote device

    No Loopback Indicates that no loopback test is running on a link or channel

    R-Remote Loopback Indicates that a remote loopback test is running on a link or channel, when you haveselected a local link or channel

    Local Loopback Indicates that a local loopback test is running on a channel

    Remote Loopback Indicates that a remote loopback test is running on a link or channel

    Link Local Loopback Indicates that a link local loopback test is running on a link

    Loopback Config No Loop, Local Loopback, Remote Loopback, Link Local Loopback

    LLB Duration (min) For link local loopback tests, the duration of the loopback test in minutes, 1255. Thisparamter is only available ifLink Local Loopback is selected in the Loopback Configdrop down list

    Forever For link local loopback tests, indicates that the loopback test should run indefinitely.This paramter is only available ifLink Local Loopback is selected in the LoopbackConfig drop down list

    [Apply] Click to begin the loopback test on the port.

    [Done] Click to close the Port Loopback Test dialog box.

  • 7/31/2019 Manual Optimux 4E1L

    47/50

    RADview Optimux-4E1/Optimux-4T1 Users Manual Chapter 4 Fault Management

    Port Level Fault Management Diagnostics Menu 4-13

    Running a Loopback Test on a Channel

    The Loopback Test command enables you to:

    View all loopback tests that are currently running on the local and remotedevices

    Run a loopback test on a channel.

    You cannot run:

    A loopback test on a channel if a loopback test is already running on a link

    A loopback test on a link if a loopback test is already running on a channel

    A remote loopback test on a channel if a remote loopback test is alreadyrunning at the opposite end of the channel.

    To view all loopback tests that are currently running on both devices:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select a device.

    2. SelectDiagnostics > Loopback Test...

    To run a loopback test on a channel:

    1. In the RADview Optimux-4E1/Optimux-4T1 window, select the channel.

    2. SelectDiagnostics > Loopback Test...

    3. In the Loopback Config drop down list, select the type of loopback test youwant to run.

    4. ClickApply.

    Figure 4-15. Local Channel Loopback Test Dialog Box

  • 7/31/2019 Manual Optimux 4E1L

    48/50

  • 7/31/2019 Manual Optimux 4E1L

    49/50

    I-1

    Index

    AAccess restrictions, 3-5Agents, polling, 3-3

    CChannel

    parameters, 3-12

    Communitiesread community, 2-2trap community, 2-2

    write community, 2-2Configuration

    device level, 3-6overview, 3-1port level, 3-10resetting, 3-9system level, 3-1

    Configuringaccess, 3-5channel parameters, 3-12device parameters, 3-6link parameters, 3-10manager list, 3-3

    polling, 3-6system information, 3-1

    Control Portconfiguring, 2-4, 2-5

    DDevice

    configuring parameters, 3-6interface information, 3-8LEDs, 2-7management, 2-8

    Device levelconfiguration, 3-6operations, 2-8

    Device mode management options, 2-8

    GGraphical user interface, 2-5

    HHardware, resetting, 3-9

    IInterface information, 3-8

    LLEDs, 2-7Link

    parameters, 3-10

    MManagement Access

    setting, 2-2

    Management optionsdevice mode, 2-8

    port mode, 2-9system mode, 2-7

    Manager List, 3-3setting, 2-2

    Managingconfiguration, 3-1

    MenuHost IP List, 2-1Manager Access, 2-3Telnet, 2-3

    Menu bar, 2-6

    OOperations

    device level, 2-8port level, 2-9system level, 2-7

    Options, system level, 3-3

    PParameters

    channel, 3-12device, 3-6link, 3-10

    Pollingagents, 3-3

    configuring, 3-6Port

    management, 2-9

    Port levelconfiguration, 3-10operations, 2-9

    Port mode management options, 2-9

    RResetting

    configuration, 3-9

  • 7/31/2019 Manual Optimux 4E1L

    50/50

    Index RADview Optimux-4E1/Optimux-4T1 Network Management Software Guide

    hardware, 3-9

    SScreen

    Manager List, 2-2

    Settingchannel parameters, 3-12device parameters, 3-6

    link parameters, 3-10system information, 3-1

    Status bar, 2-6System

    management, 2-7setting system information, 3-1viewing system information, 3-1

    System levelconfiguration, 3-1operations, 2-7options, 3-3

    System mode management options, 2-7

    UUsing

    graphical user interface, 2-5menu bar, 2-6

    VViewing

    access, 3-5channel parameters, 3-12device parameters, 3-6interface information, 3-8LEDs, 2-7link parameters, 3-10manager list, 3-3status bar, 2-6system information, 3-1