m-series model mg transmitter with digital output€¦ · the m-series model mg transmitter...
TRANSCRIPT
Level Plus®
Liquid-Level Sensors
With Temposonics® Technology
M-Series Model MG TransmitterDigital Output
Product Specification
SENSORS
®
550784 F
Product overview
The M-Series Model MG transmitter satisfies the demand for a digital communication interface in the Liquid Level marketplace for vessels from 20 inches to 60 feet.
Outputs for the Model MG include Modbus, FOUNDATION™ fieldbus, and DDA (a proprietary ASCII protocol). Modbus and DDA outputs are communicated via a 4-wire multi-drop power and data bus (EIA 485), whereas FOUNDATION™ fieldbus has a specified 3-wire bus. Utilizing the bus networks eliminates the requirements for individual cable runs from each tank and these three data formats provide a direct interface to most types of computers and digital communica-tion equipment.
The Model MG provides 3-in-1 sensing through one process opening of the product level, the interface level, and temperature. The Modbus and FOUNDATION™ fieldbus output also allow the user to measure volume from a 100 point strap table with the option for temperature correction. Once the transmitter is installed and calibrated there is no requirement for scheduled maintenance or recalibration. Set it and forget it!
FeatureS
Modbus and F � OuNDatION™ fieldbus Output3-in-1 Measurement �
Product Interface temperature
100 point strap table �No Scheduled Maintenance or recalibration �aPI temperature Corrected Volumes �Non-linearity 0.008% F.S. �
aPPlICatIONS
Custody transfer �Inventory Control �Bulk Storage �Sanitary Process Control �
MarketS
Petroleum/Petrochemical �Propane terminals �Biotech / Pharmaceuticals �Food and Beverage �Water and Wastewater �
NeMa type 4X enclosureSanitary transmitter
Single Chamber Housing rigid transmitter
Dual Chamber HousingFlexible transmitter
All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Go to www.mtssensors.com for the latest support documentation.
M-Series Model MR Liquid-Level Transmitter, Digital Output - Product Specification, 550784 F MTS Sensors2
Product specifications
Parameters Specifications
leVel OutPut
Measured variable: Product level and interface level
Output: Modbus RTU, DDA or FOUNDATION™ fieldbus
Measurement range:
Flexible transmitter: 3048 mm (120 in.) to 22000 mm (866 in.) • §rigid transmitter: 508 mm (20 in.) to 7620 mm (300 in.) • §Sanitary transmitter: 508 mm (20 in.) to 7620 mm (300 in.) • §
Non-linearity: 0.008% F.S. or 1.46 mm (1/16 in.)*
Hysteresis: 0.002% F.S. or 0.366 mm (0.01 in.)*(any direction)
resolution: Up to 0.025 mm (0.001 in.)
time constant: 1-3 second (typical)
teMPerature OutPut
Measured variable:
Average and multi-point temperature Up to 12 Modbus ∞Up to 5, DDA and FOUNDATION™ fieldbus
temperature accuracy:
±0.28 °C (±0.5 °F)
Computed variables(Modbus and FOuNDatION™ fieldbus):
Gross volumeMassNet volume Alarms
eleCtrONICS
Input voltage range:
Modbus and DDa:10.5 to 30.1 Vdc, 28 Vdc maximum for I.S. ATEX approval FOuNDatION™ fieldbus: 9 to 32 Vdc bus powered
reverse polarity protection:
Series diode
lightning/transient protection:
Stage 1: line-to-ground surge suppres-sors; IEC 61000-4-5Stage 2: line-to-line and line-to-ground transient suppressors; IEC 61000-4-4
Safety approvals:Modbus and DDa
FM/CSa: Explosion-proof Class I, Groups B, C and DClass II, Groups E, F and GDivision 1, NEMA Type 4X Models: Explosion-proof housing req. FM/CSa: Intrinsically safe Class I, Groups A, B, C and DClass II, Groups E, F and GDivision I, NEMA Type 4X Division 2, Non-Incendive ateX: Intrinsically safe EEx ia IIA & IIB T4 (con tact factory for model numbers).
Safety approvalsFOuNDatION™ fieldbus:
FM/CSa: Explosion-proof Class I, Groups B, C and DClass II, Groups E, F and GDivision 1, NEMA Type 4X Models: Explosion-proof housing required FM/CSa: Intrinsically safe pendingateX: Intrinsically safe pending
Parameters Specifications
CalIBratION
Zero adjust range:
Anywhere within the active length.
Span adjust range:
Full scale to 152 mm (6 in.) from zero
eNVIrONMeNtal
Sealing: O-Ring sealed for outdoor use (NEMA Type 4X)
Humidity: 0 to 100% relative humidity, non-condensing
Operating temperatures:
electronics: -40 °C (-40 °F) to 71 °C (160 °F) Sensing element: -40 °C (-40 °F) to 125 °C (257 °F) ◊temperature element: -40 °C (-40 °F) to 105 °C (221 °F)
Vessel pressure: Dependent on float pressure rating (18.7 bar (275 psi) max. - flexible outer pipe) ‡
Materials (wetted parts):
Wetted parts: 316L stainless steel † Non-wetted parts: 316L SS, Epoxy coated aluminum
FIelD INStallatION
length (excluding housing):
508 mm (20 in.) to 18288 m (720 ft.)
Housing dimensions:
Single chamber enclosure: 127 mm (5 in.) by 123 mm (4.84 in.). 119 mm (4.70 in.) O.D.Dual chamber enclosure: 127 mm (5 in.) by 177 mm (6.95 in.). 109 mm (4.28 in.) O.D.NeMa type 4X enclosure: 81 mm (3.2 in.) by 123 mm (4.85 in.)
Mounting: rigid pipe: 3/4 in. NPT adjustable fitting, flange mountFlexible pipe: 1 in. NPT adjustable fitting, Tri-clamp
Wiring: Modbus or DDa
4-wire connections + earth ground/tank ground, 1/2 in. NPT conduit opening NEMA (NEMA Type 4X), 3/4 in. NPT (XP housing)
Wiring:FOuNDatION™ Fieldbus
3-wire “Type A” fieldbus cable 1/2 in. NPT conduit opening (NEMA Type 4X), 3/4 in. NPT XP housing
Notes: * Whichever is greater** Must specify at time of order, not on all units.† Contact factory for other materials.• Contact factory for longer lengths.◊ Length dependent. Contact factory for higher temperatures.‡ Contact factory for higher pressures.§ Flexible sensing elements come standard with flexible pipes. Rigid sensing
elements come standard with rigid pipes. A flexible sensing element is optional for a rigid pipe configuration.∞ Minimum length of 2032 mm (80 in.) for 12 temperature positions. All
specifications are subject to change, contact MTS for specifications critical to your needs.
M-Series Model MG Liquid-Level Transmitter, Digital Output - Product Specification, 550784 FMTS Sensors 3
typical installation and mounting, rigid pipe
Illustrated below are three typical product installation and mounting methods for rigid pipe applications. For information about typical floating roof and typical cone roof installation methods see page 6.
rIgID traNSMItter PIPe INStallatION aND MOuNtINg reFereNCeS
Riser
3/4 in. NPT fitting
Tip of transmitter
Tank flange(provided by customer)
95 mm (3.75 in.)Minimum height
127 mm(5 in.)
210 mm(8.25 in.) max.
121 mm(4.75 in.) O.D.
Threaded 3/4 in. NPT - compression fitting, male
Tank flange
Outer pipe16 mm(0.625 in.)O.D.
Level 1 Float
95 mm (3.75 in.)
Transmitter InactiveZone
(see table)
Welded RF flange
165 mm(6.5 in.)
Level 2 Float(Order Separately)
Tip of Transmitter
(Order Separately)
DT Custom PositionsModbus
DDA & F.F.
12
11
10
9
8
7
6
5
4
3
2
1
5
4
3
2
1
Order length508 mm (20 in.) to7620 mm (300 in.)
Teflon,6100 mm (240 in.) max.
traNSMItter INaCtIVe ZONe: 316l SS, 74 MM (2.9 IN.)
Notes:
Drawings are for reference only. 1. Contact factory for engineering drawings.2. Application worksheets are available at www.mtssensors.com.3.
74 mm (2.9 in.) min.Inactive zone
3/4 in. NPTAdjustable fitting
Tip of transmitter
Tank flange(provided by customer)
Order length
95 mm (3.75 in.)minimum
Pipe diameter16 mm (0.625 in.)
M-Series Model MR Liquid-Level Transmitter, Digital Output - Product Specification, 550784 F MTS Sensors4
typical installation and mounting, sanitary pipe
Illustrated below are three typical product installation and mounting methods for sanitary pipe applications. For information about typical floating roof and typical cone roof installation methods see page 6.
SaNItary PIPe INStallatION aND MOuNtINg reFereNCeS
Tip of transmitter
Sanitary process connection,sanitary cap(welded to sensor pipe)
Sanitary clamp(customer supplied)
Mating process connection(customer supplied)
Sanitary float (permanently mounted on some pipe styles)
Top view Riser
123 mm(4.85 in.)
81 mm(3.19 in.)
152 mm(6 in.)
Customer supplied cable(15 ft.) connected toterminal strip
Sanitary Process Connection (Size)
Transmitter InactiveZone
(see table)
XP Housing63.5 mm (2.5 in.)NEMA Housing48 mm (1.9 in.)
Level 1 Float(Order Separately)
Order Length508 mm (20 in.) to 7620 mm (300 in.)
Pipe, 16 mm(0.625 in.) O.D.Constructed of316L SS
Level 2 Float(Order Separately)
DT Custom PositionsModbus
DDA & F.F.
12
11
10
9
8
7
6
5
4
3
2
1
5
4
3
2
1
Notes:Drawings are for reference only. 1. Contact factory for engineering drawings.2. Application worksheets are available at www.mtssensors.com.3.
traNSMItter INaCtIVe ZONeS
TB, CP 81 mm 3.2 in.
DP, DN 74 mm 2.9 in.
TBSanitary*
CPClean-in-place
DNDrain-in-place,no through hole
DPDrain-in-place
w/end plug
This end plug style has permanently mounted floatsfloats cannot be removed from pipe.
Inactive zone:81 mm (3.2 in.)from tip (typical)
Inactive zone:74 mm (2.9 in.)from tip (typical)
Inactive zone:81 mm (3.2 in.)from tip (typical)
Inactive zone:74 mm (2.9 in.)from tip (typical)
**
M-Series Model MG Liquid-Level Transmitter, Digital Output - Product Specification, 550784 FMTS Sensors 5
typical installation and mounting, flexible pipe
Illustrated below are three typical product installation and mounting methods for flexible pipe applications. For information about typical floating roof and typical cone roof installation methods see page 6.
FleXIBle PIPe INStallatION aND MOuNtINg reFereNCeS
1 in. NPTadjustable fitting
Tank flange(provided by customer)
Bottom-fixing weight, magnetor hook
Stainless-steelflexible pipe
Interface float
Riser
Product float
127 mm(5 in.)
210 mm(8.25 in.) max.
121 mm(4.75 in.) O.D.
traNSMItter INaCtIVe ZONeS
<25 ft. 76 mm 3 in.
<40 ft. 96.5 mm 3.8 in.
<60 ft. 119 mm 4.7 in.
TotalInactive Zone
TransmitterInactive Zone
See Table
Level 1 Float(Order Separately)
Level 2 Float(Order Separately)
Order length3 m (120 in.) to18 m (720 in.)
Outer Pipe,Constructed of 316L SS
Flexible Pipe,22 mm (0.875 in.)
O.D.
305 mm(12 in.)
Threaded 1 in. NPT - Compression Fitting, Male
Tank Flange
686 mm(27 in.)
OptionalWelded RF Flange
76 mm(3 in.)
2 in.(typ.)
127 mm(5 in.)
Bottom-FixingHook
DT Custom PositionsModbus
DDA & F.F.
12
11
10
9
8
7
6
5
4
3
2
1
5
4
3
2
1
Bottom-Fixing Weight Bottom-Fixing Magnet
Notes:
Drawings are for reference only. 1. Contact factory for engineering drawings.2. Application worksheets are available at www.mtssensors.com.3.
M-Series Model MR Liquid-Level Transmitter, Digital Output - Product Specification, 550784 F MTS Sensors6
typical tank mounting and floating roof and cone roof installations
Illustrated below are tank mounting, floating roof installation, floating roof and cone roof methods.
tyPICal taNk MOuNtINg Single entry into tank �easy to install �Product and interface level measurement �Single and multi-point temperature �average temperature of submerged Dts �Modbus and F � OuNDatION™ fieldbus outputs
provide gross volumes, net volumes, mass and alarms
DDa output provides product and interface, � level and temperature
Note:
Drawings are for reference only. Contact factory for engineering drawings.
Product level
3/4 in. NPTadjustable fitting95 mm (3.75 in.)
(typical)
Vessel flange
Vessel bottom
Float magnet
Interface
127 mm(5 in.)
210 mm(8.25 in.) max.
121 mm (4.75 in.) O.D.
Order length
Optional stop collarE-ring float clip
eXterNal FlOatINg rOOF INStallatION
Gauge welland cover
Productlevel
Customerwiringconduit
Customer providedtank-gauge bracket
1 in. NPT
Float
Flex pipe
Bottom fixingmagnet or weight
Optional BS&Wfloat
Floating roof
127 mm (5 in.)
210 mm(8.25 in.)max.
121 mm(4.75 in.) O.D.
MTS
tyPICal FIXeD FlOatINg rOOF INStallatION
Product level
Customerwiringconduit
Float
Flex pipe
Bottom-fixingmagnet or weight
Tank top
Blind-flange drilledfor 1 in. NPTExisting tank riser
127 mm (5 in.) 210 mm(8.25 in.) max.
121 mm(4.75 in.) O.D.
MTS
M-Series Model MG Liquid-Level Transmitter, Digital Output - Product Specification, 550784 FMTS Sensors 7
Interface and enclosure options
MtS DDa PrOtOCOl
MTS DDA proprietary protocol IS developed for use in intrinsically safe areas. The M-Series Model MG transmitter is backwards compatible with existing IS installations of D8/D9 and LDF MTS sensors, as long as the total number of transmitters does not exceed 8 per monitor. The DDA protocol allows the transmitter to be in a low power or “idle” mode while not pro cessing commands. This protocol allows for level, interface and temperature data to be output from the transmitter.
MODBuS rtu PrOtOCOl
The Modbus RTU protocol is available for use in explosion-proof areas and allows the M-Series Model MG transmitter to communicate level, temperature and volume information directly from the transmitter head.
FOuNDatION™ FIelDBuS PrOtOCOl
FOUNDATION™ fieldbus H1 is intended primarily for process control, field-level interface and device integration. Running at 31.25 kbit/s, the technology interconnects field networked devices such as transmitters and actuators. FOUNDATION™ fieldbus H1 is designed to support intrinsi-cally safe (I.S.) applications and operate on an existing twisted pair instrument cabling with power and signal on the same wire.
eNClOSure OPtIONS
Note:
Drawings are for reference only. Contact factory for engineering drawings.
NeMa tyPe 4X eNClOSure
Top View
123 mm(4.85 in.) O.D.
81 mm(3.19 in.)
152 mm(6 in.)
Factory supplied cableconnected to internalterminal strips
SINgle CaVIty eNClOSure
123 mm(4.84 in.)
3/4 in. NPTconduit access
127 mm(5 in.)
210 mm(8.25 in.) max.121 mm
(4.75 in.) O.D.
Dual CaVIty eNClOSure
127 mm(5 in.)
210 mm(8.25 in.) max.
121 mm(4.75 in.)
O.D.
177 mm(6.95 in.)
81 mm(3.18 in.)
3/4 in. NPTconduit access
M-Series Model MR Liquid-Level Transmitter, Digital Output - Product Specification, 550784 F MTS Sensors8
M-Series Model Mg, Digital transmitter - Ordering information
Use the guide below to build a model number for the M-Series Model MG transmitter. A model number is required to place an order and is helpful in identifying installed products. For standard accessory information, refer to page 9 or the Liquid-Level Accessories Catalog (part no. 551103) for additional information.
traNSMItter MODel = M 1
M = Magnetostrictive transmitter
tyPe = g 2
g = Digital output level transmitter
INPut POWer = a 3
a = 24 Vdc
OutPut POWer = 4M = Modbus RTU data format t = Modbus sight glass
D = MTS DDA
F = FOUNDATION™ fieldbus S = FOUNDATION™ fieldbus sight glassHOuSINg tyPe = 5
3 = NEMA Type 4X, 316L stainless steel with NPT and internal terminal blocks (Intrinsically safe only)
C = Dual cavity (explosion-proof and intrinsically safe)
B = Single cavity (explosion-proof and intrinsically safe) l = NEMA Type 4X, 316L w/6-pin connector
eleCtrONICS MOuNtINg = 61 = Integral electronics
traNSMItter PIPe = 7B = Industrial end-plug with stop collar F = Sanitary, drain-in-place, no hole, DN
C = Sanitary, T-bar, TB M = Flexible w/bottom fixing hook (stainless steel only)
D = Sanitary, drain-in-place, DP N = Flexible w/bottom fixing weight (stainless steel only)
e = Sanitary, clean-in-place, CP P = Flexible w/bottom fixing magnet (stainless steel only)
MaterIalS OF CONStruCtION (WetteD PartS) = 8Note: contact factory for other materials
1 = 316L stainless steel a = Teflon2 = Electropolished 316L stainless steel Ra 15 C = CRN Approved
PrOCeSS CONNeCtION tyPe = 91 = NPT, Adjustable 4 = Sanitary, welded5 = Sanitary, adjustable 6 = 150 lbs. welded RF flange
7 = 300 lbs. Welded RF flange 8 = 600 lbs. welded RF flange
X = None
PrOCeSS CONNeCtION SIZe = 10a = ¾ in. (NPT only) Rigid pipe only B = 1 in. (NPT only) Flex pipe only
C = 1½ in. D = 2 in.
e = 2½ in. F = 3 in.
g = 4 in. H = 5 in. (except sanitary)
J = 6 in. X = None
teMPerature (DIgItal tHerMOMeterS) = 110 = None 1 = One DT, 203 mm (8 in.) when order length is less than
914 mm (36 in.)2 = One DT, customer defined position
(if this option is selected, option 18 E must also be selected)5 = Five DTs, evenly spaced as API
k = Twelve DTs, evenly spaced per API 6 = Five DTs, customer defined position (if this option is selected, option 18 E must also be selected)
l = Twelve DTs, customer defined position
uNIt OF MeaSureMeNt = 12M = Metric (millimeters) Encode length in millimeters if using metric
(XXXXX mm)u = US Customary (inches) Encode length in inches if
ordering in US Customary (XXX.XX in.)
leNgtH _ _ _ _ _ _ = 13-17
= Order length based on unit of measurement - Rigid transmitter pipe length;\: 508 mm (20 in.) to 7620 mm (300 in.) and Flexible transmitter pipe length: 3050 mm (120 in.) to 22000 mm (866 in.)
SPeCIal = 18S = Standard product e = Engineering special
(not affecting agency controlled parts or features)
M-Series Model MG Liquid-Level Transmitter, Digital Output - Product Specification, 550784 FMTS Sensors 9
Model Mg - accessories overview, floats
Product & Dimensions Pressure temp. Magnet Offset type Specific
gravity Material Weight Offset
Part Number
StaNDarD rIgID FlOat18 mm(0.70 in.) dia.
47 mm(1.85 in.) dia.
76.5 mm(3.01 in.) 29.3 bar
(425 psi)149 °C (300 °F) No Product
0.65 SS No 251981-1
0.67 SS Yes 251981-2*
0.68 Hastelloy C No 251981-3
0.71 Hastelloy C Yes 251981-4*
CrItICal SerVICe FlOat
18 mm (0.7 in.) dia.
89 mm (3.5 in.) dia.
91 mm(3.57 in.) 29.3 bar
(425 psi)149 °C (300 °F) No Critical
service
0.43 SS No 251469-1
0.45 SS Yes 251469-2*
StaNDarD SaNItary FlOat18 mm(0.7 in.) dia.
47 mm(1.85 in.) dia.
Centerline of magnet
89 mm(3.5 in.)
108 mm(4.25 in.)
10.3 bar(150 psi)
149 °C (300 °F) Yes Sanitary 0.66
SS200 Grit/
Ra 25
No 401513-1
Yes 401513-2*
SS240 Grit/
Ra 15
No 401513-3*
Yes 401513-4*
StaNDarD FleX FlOat
Magnet
28 mm(1.10 in.)
130 mm(5.11 in.)
127 mm(4.98 in.)
63 mm(2.49 in.)
37.9 bar(550 psi)
149 °C (300 °F) No
Product0.44 SS No 250709-1*
0.52 Hastelloy C No 250709-3*
Interface
0.90 - 0.96SS No 250714-1*
Hastelloy C No 250714-3*
1.03 - 1.10SS No 250855-1*
Hastelloy C No 250855-3*
Notes: *Call the factory for specific lead times. Typical lead time exceeds lead time of the sensor.1. Drawing contained in this document are for reference only. Contact the factory for engineering drawings.2.
M-Series Model MR Liquid-Level Transmitter, Digital Output - Product Specification, 550784 F MTS Sensors
Model Mg - accessories overview, float options (for all applications)
Product & Dimensions Pressure temp. Magnet Offset
Specific gravity
Material/type
Weight Offset
Part Number
lONg-gauge FleX FlOatS
28 mm(1.10 in.) dia.
91.5 mm(3.6 in.) dia.
87.5 mm(3.44 in.)
44 mm
(1.72 in.)
C MagnetL29.3 bar(425 psi)
149 °C (300 °F) No
0.54 SS No 251223-1
0.65 Hastelloy C No 251223-3*
130 mm(5.11 in.)
127 mm(4.98 in.)
116 mm(4.55 in.)
28 mm (1.1 in.)
CL Magnet
37.9 bar(550 psi)
149 °C (300 °F) Yes 0.44 SS
No 201248-1
Yes 201248-2*
17.2 bar(250 psi)
149 °C (300 °F) No
0.44 SS
No 251426-1*
Yes 251426-2*
0.47 Hastelloy C
No 251426-3*
Yes 251426-4*
Notes:
Be sure that the float specific gravity is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 1. For interface measurement: A minimum of 0.05 specific gravity differential is required between the upper and lower liquids. 2. When the magnet is not shown, the magnet is positioned at the center line of float. 3. Offset weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the 4.
transmitter tube at all times. The offset option is required for installations that must conform to PTB standards.*Call the factory for specific lead times. Typical lead time exceeds lead time of the sensor.5. Drawing contained in this document are for reference only. Contact the factory for engineering drawings.6.
10
48 mm(1.9 in.) dia.
6.95 in.(00.0 mm)178 mm
(7 in.)
178 mm(7 in.)
M-Series Model MG Liquid-Level Transmitter, Digital Output - Product Specification, 550784 FMTS Sensors 11
Nitrophyl product and interface float options
Notes:
Floats 201649-1 and 201650-1 may be used with propane, butane, and liquefied petroleum gas. Precautions should be taken to ensure that no other 1. contaminant’s are present in these liquids, which may not be compatible with Nitrophyl.
When magnet is not shown, the magnet is positioned at the centerline of the float.2.
Product & Dimensions Pressure temp. Magnet Offset
Specific gravity
Material/type
Weight Offset
Part Number
NItrOPHyl PrODuCt / INterFaCe FlOatS
Stainlesscover
Stainlessfloat post
Nitrophyl base
168 mm(6.61 in.)
C Magnet 152 mm(5.99 in.)
152.5 mm(6.00 in.) dia.
30 mm(1.19 in.)
I.D.
L
17.2 bar(250 psi) 104 °C
(220 °F)Yes
0.65 Nitrophyl/Product No 252998*
0.90 -0.96
Nitrophyl/Interface
No 252999*
uNIteD StateSMtS Systems CorporationSensors Division
3001 Sheldon DriveCary, NC 27513Tel: (800) 633-7609Fax: (919) 677-0200 (800) [email protected]
gerMaNyMtS Sensor technologiegmbH & Co. kg
Auf dem Schüffel 9D - 58513 LüdenscheidTel: +49 / 23 51 / 95 87-0Fax: +49 / 23 51 / 56 [email protected]
Part Number: 08-08, 03-09 550784 revision FMTS, Level Plus and Temposonics, are registered trademarks of MTS Systems Corporation.
All other trademarks are the property of their respective owners.All Temposonics sensors are covered by US patent number 5,545,984. Additional patents are pending.
Printed in USA. Copyright © 2008 MTS Systems Corporation. All Rights Reserved in all media.
JaPaNMtS Sensors technologyCorporation
Ushikubo Bldg.737 Aihara-cho, Machida-shiTokyo 194-0211, JapanTel: +81 (42) 775 / 3838Fax: +81 (42) 775 / [email protected]
SENSORS
®
FMAPPROVED
accessories overview
aCCeSSOrIeS PrODuCt DeSCrIPtIONS MtS Part NO.
M-SerIeS PC SetuP SOFtWare
M-Series Modbus setup software, shipped with the sensor, will allow the setup and calibra-tion of M-Series digital sensors. The software communicates via RS-485 to RS-232 adapter. 625051
M-Series Modbus setup software, shipped with the sensor, will allow the setup and calibration of M-Series digital sensors. 625052
RS-485 to RS-232 adapter 380075
M-Series Digital PC setup software (DDA) 625053
H100 lIQuID-leVel Ht100 HaND HelD terMINal (DDa ONly)
The liquid-level HT100 is a convenient and cost-effective tool for supporting MTS Direct Digital Access (DDA) sensors, side tank indicators and tank moni tors in the field. The hand-held microprocessor-based unit performs all the operations necessary for setting up, troubleshooting and maintaining an MTS DDA tank gauging system. Using the HT100 allows users to program and per form diagnostics on-site, saving time and money.
251259
Disposable RS-485 Surge protector, go to www.bb-elec.com (part no. 485FPP) 370542
Belden cable, 4-wire RS-485 cable, www.belden.com 8162
MagNet aND WeIgHt aSSeMBlIeS
51 mm(2 in.)
76 mm(3 in.)
150 lb. pull for LDF long sensor and M-Series sensors. 560604
51 mm(2 in.)
127 mm(5 in.)
Standard 11 lb. weight for M-Series sensors. 401059
A
A
191 mm(7.5 in.) dia.
165 mm(6.5 in.) dia.
Section A-A
84 mm(3.3 in.)
3 mm(0.13 in.)
16 mm(0.63 in.) Low liftoff 11 lb. weight assembly Use with float
part no. 252998/252999 402364
Label, 3A Sanitary 400868