m-series model mg transmitter with digital output€¦ · the m-series model mg transmitter...

12
Level Plus ® Liquid-Level Sensors With Temposonics ® Technology M-Series Model MG Transmitter Digital Output Product Specification SENSO RS ® 550784 F Product overview The M-Series Model MG transmitter satisfies the demand for a digital communication interface in the Liquid Level marketplace for vessels from 20 inches to 60 feet. Outputs for the Model MG include Modbus, FOUNDATION™ fieldbus, and DDA (a proprietary ASCII protocol). Modbus and DDA outputs are communicated via a 4-wire multi-drop power and data bus (EIA 485), whereas FOUNDATION™ fieldbus has a specified 3-wire bus. Utilizing the bus networks eliminates the requirements for individual cable runs from each tank and these three data formats provide a direct interface to most types of computers and digital communica- tion equipment. The Model MG provides 3-in-1 sensing through one process opening of the product level, the interface level, and temperature. The Modbus and FOUNDATION™ fieldbus output also allow the user to measure volume from a 100 point strap table with the option for temperature correction. Once the transmitter is installed and calibrated there is no requirement for scheduled maintenance or recalibration. Set it and forget it! FEATURES Modbus and F OUNDATIONfieldbus Output 3-in-1 Measurement Product Interface Temperature 100 point strap table No Scheduled Maintenance or Recalibration API Temperature Corrected Volumes Non-linearity 0.008% F.S. APPLICATIONS Custody Transfer Inventory Control Bulk Storage Sanitary Process Control MARKETS Petroleum/Petrochemical Propane Terminals Biotech / Pharmaceuticals Food and Beverage Water and Wastewater NEMA Type 4X Enclosure Sanitary Transmitter Single Chamber Housing Rigid Transmitter Dual Chamber Housing Flexible Transmitter All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Go to www.mtssensors.com for the latest support documentation.

Upload: truongxuyen

Post on 11-Jun-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

Level Plus®

Liquid-Level Sensors

With Temposonics® Technology

M-Series Model MG TransmitterDigital Output

Product Specification

SENSORS

®

550784 F

Product overview

The M-Series Model MG transmitter satisfies the demand for a digital communication interface in the Liquid Level marketplace for vessels from 20 inches to 60 feet.

Outputs for the Model MG include Modbus, FOUNDATION™ fieldbus, and DDA (a proprietary ASCII protocol). Modbus and DDA outputs are communicated via a 4-wire multi-drop power and data bus (EIA 485), whereas FOUNDATION™ fieldbus has a specified 3-wire bus. Utilizing the bus networks eliminates the requirements for individual cable runs from each tank and these three data formats provide a direct interface to most types of computers and digital communica-tion equipment.

The Model MG provides 3-in-1 sensing through one process opening of the product level, the interface level, and temperature. The Modbus and FOUNDATION™ fieldbus output also allow the user to measure volume from a 100 point strap table with the option for temperature correction. Once the transmitter is installed and calibrated there is no requirement for scheduled maintenance or recalibration. Set it and forget it!

FeatureS

Modbus and F � OuNDatION™ fieldbus Output3-in-1 Measurement �

Product Interface temperature

100 point strap table �No Scheduled Maintenance or recalibration �aPI temperature Corrected Volumes �Non-linearity 0.008% F.S. �

aPPlICatIONS

Custody transfer �Inventory Control �Bulk Storage �Sanitary Process Control �

MarketS

Petroleum/Petrochemical �Propane terminals �Biotech / Pharmaceuticals �Food and Beverage �Water and Wastewater �

NeMa type 4X enclosureSanitary transmitter

Single Chamber Housing rigid transmitter

Dual Chamber HousingFlexible transmitter

All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Go to www.mtssensors.com for the latest support documentation.

Page 2: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

M-Series Model MR Liquid-Level Transmitter, Digital Output - Product Specification, 550784 F MTS Sensors2

Product specifications

Parameters Specifications

leVel OutPut

Measured variable: Product level and interface level

Output: Modbus RTU, DDA or FOUNDATION™ fieldbus

Measurement range:

Flexible transmitter: 3048 mm (120 in.) to 22000 mm (866 in.) • §rigid transmitter: 508 mm (20 in.) to 7620 mm (300 in.) • §Sanitary transmitter: 508 mm (20 in.) to 7620 mm (300 in.) • §

Non-linearity: 0.008% F.S. or 1.46 mm (1/16 in.)*

Hysteresis: 0.002% F.S. or 0.366 mm (0.01 in.)*(any direction)

resolution: Up to 0.025 mm (0.001 in.)

time constant: 1-3 second (typical)

teMPerature OutPut

Measured variable:

Average and multi-point temperature Up to 12 Modbus ∞Up to 5, DDA and FOUNDATION™ fieldbus

temperature accuracy:

±0.28 °C (±0.5 °F)

Computed variables(Modbus and FOuNDatION™ fieldbus):

Gross volumeMassNet volume Alarms

eleCtrONICS

Input voltage range:

Modbus and DDa:10.5 to 30.1 Vdc, 28 Vdc maximum for I.S. ATEX approval FOuNDatION™ fieldbus: 9 to 32 Vdc bus powered

reverse polarity protection:

Series diode

lightning/transient protection:

Stage 1: line-to-ground surge suppres-sors; IEC 61000-4-5Stage 2: line-to-line and line-to-ground transient suppressors; IEC 61000-4-4

Safety approvals:Modbus and DDa

FM/CSa: Explosion-proof Class I, Groups B, C and DClass II, Groups E, F and GDivision 1, NEMA Type 4X Models: Explosion-proof housing req. FM/CSa: Intrinsically safe Class I, Groups A, B, C and DClass II, Groups E, F and GDivision I, NEMA Type 4X Division 2, Non-Incendive ateX: Intrinsically safe EEx ia IIA & IIB T4 (con tact factory for model numbers).

Safety approvalsFOuNDatION™ fieldbus:

FM/CSa: Explosion-proof Class I, Groups B, C and DClass II, Groups E, F and GDivision 1, NEMA Type 4X Models: Explosion-proof housing required FM/CSa: Intrinsically safe pendingateX: Intrinsically safe pending

Parameters Specifications

CalIBratION

Zero adjust range:

Anywhere within the active length.

Span adjust range:

Full scale to 152 mm (6 in.) from zero

eNVIrONMeNtal

Sealing: O-Ring sealed for outdoor use (NEMA Type 4X)

Humidity: 0 to 100% relative humidity, non-condensing

Operating temperatures:

electronics: -40 °C (-40 °F) to 71 °C (160 °F) Sensing element: -40 °C (-40 °F) to 125 °C (257 °F) ◊temperature element: -40 °C (-40 °F) to 105 °C (221 °F)

Vessel pressure: Dependent on float pressure rating (18.7 bar (275 psi) max. - flexible outer pipe) ‡

Materials (wetted parts):

Wetted parts: 316L stainless steel † Non-wetted parts: 316L SS, Epoxy coated aluminum

FIelD INStallatION

length (excluding housing):

508 mm (20 in.) to 18288 m (720 ft.)

Housing dimensions:

Single chamber enclosure: 127 mm (5 in.) by 123 mm (4.84 in.). 119 mm (4.70 in.) O.D.Dual chamber enclosure: 127 mm (5 in.) by 177 mm (6.95 in.). 109 mm (4.28 in.) O.D.NeMa type 4X enclosure: 81 mm (3.2 in.) by 123 mm (4.85 in.)

Mounting: rigid pipe: 3/4 in. NPT adjustable fitting, flange mountFlexible pipe: 1 in. NPT adjustable fitting, Tri-clamp

Wiring: Modbus or DDa

4-wire connections + earth ground/tank ground, 1/2 in. NPT conduit opening NEMA (NEMA Type 4X), 3/4 in. NPT (XP housing)

Wiring:FOuNDatION™ Fieldbus

3-wire “Type A” fieldbus cable 1/2 in. NPT conduit opening (NEMA Type 4X), 3/4 in. NPT XP housing

Notes: * Whichever is greater** Must specify at time of order, not on all units.† Contact factory for other materials.• Contact factory for longer lengths.◊ Length dependent. Contact factory for higher temperatures.‡ Contact factory for higher pressures.§ Flexible sensing elements come standard with flexible pipes. Rigid sensing

elements come standard with rigid pipes. A flexible sensing element is optional for a rigid pipe configuration.∞ Minimum length of 2032 mm (80 in.) for 12 temperature positions. All

specifications are subject to change, contact MTS for specifications critical to your needs.

Page 3: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

M-Series Model MG Liquid-Level Transmitter, Digital Output - Product Specification, 550784 FMTS Sensors 3

typical installation and mounting, rigid pipe

Illustrated below are three typical product installation and mounting methods for rigid pipe applications. For information about typical floating roof and typical cone roof installation methods see page 6.

rIgID traNSMItter PIPe INStallatION aND MOuNtINg reFereNCeS

Riser

3/4 in. NPT fitting

Tip of transmitter

Tank flange(provided by customer)

95 mm (3.75 in.)Minimum height

127 mm(5 in.)

210 mm(8.25 in.) max.

121 mm(4.75 in.) O.D.

Threaded 3/4 in. NPT - compression fitting, male

Tank flange

Outer pipe16 mm(0.625 in.)O.D.

Level 1 Float

95 mm (3.75 in.)

Transmitter InactiveZone

(see table)

Welded RF flange

165 mm(6.5 in.)

Level 2 Float(Order Separately)

Tip of Transmitter

(Order Separately)

DT Custom PositionsModbus

DDA & F.F.

12

11

10

9

8

7

6

5

4

3

2

1

5

4

3

2

1

Order length508 mm (20 in.) to7620 mm (300 in.)

Teflon,6100 mm (240 in.) max.

traNSMItter INaCtIVe ZONe: 316l SS, 74 MM (2.9 IN.)

Notes:

Drawings are for reference only. 1. Contact factory for engineering drawings.2. Application worksheets are available at www.mtssensors.com.3.

74 mm (2.9 in.) min.Inactive zone

3/4 in. NPTAdjustable fitting

Tip of transmitter

Tank flange(provided by customer)

Order length

95 mm (3.75 in.)minimum

Pipe diameter16 mm (0.625 in.)

Page 4: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

M-Series Model MR Liquid-Level Transmitter, Digital Output - Product Specification, 550784 F MTS Sensors4

typical installation and mounting, sanitary pipe

Illustrated below are three typical product installation and mounting methods for sanitary pipe applications. For information about typical floating roof and typical cone roof installation methods see page 6.

SaNItary PIPe INStallatION aND MOuNtINg reFereNCeS

Tip of transmitter

Sanitary process connection,sanitary cap(welded to sensor pipe)

Sanitary clamp(customer supplied)

Mating process connection(customer supplied)

Sanitary float (permanently mounted on some pipe styles)

Top view Riser

123 mm(4.85 in.)

81 mm(3.19 in.)

152 mm(6 in.)

Customer supplied cable(15 ft.) connected toterminal strip

Sanitary Process Connection (Size)

Transmitter InactiveZone

(see table)

XP Housing63.5 mm (2.5 in.)NEMA Housing48 mm (1.9 in.)

Level 1 Float(Order Separately)

Order Length508 mm (20 in.) to 7620 mm (300 in.)

Pipe, 16 mm(0.625 in.) O.D.Constructed of316L SS

Level 2 Float(Order Separately)

DT Custom PositionsModbus

DDA & F.F.

12

11

10

9

8

7

6

5

4

3

2

1

5

4

3

2

1

Notes:Drawings are for reference only. 1. Contact factory for engineering drawings.2. Application worksheets are available at www.mtssensors.com.3.

traNSMItter INaCtIVe ZONeS

TB, CP 81 mm 3.2 in.

DP, DN 74 mm 2.9 in.

TBSanitary*

CPClean-in-place

DNDrain-in-place,no through hole

DPDrain-in-place

w/end plug

This end plug style has permanently mounted floatsfloats cannot be removed from pipe.

Inactive zone:81 mm (3.2 in.)from tip (typical)

Inactive zone:74 mm (2.9 in.)from tip (typical)

Inactive zone:81 mm (3.2 in.)from tip (typical)

Inactive zone:74 mm (2.9 in.)from tip (typical)

**

Page 5: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

M-Series Model MG Liquid-Level Transmitter, Digital Output - Product Specification, 550784 FMTS Sensors 5

typical installation and mounting, flexible pipe

Illustrated below are three typical product installation and mounting methods for flexible pipe applications. For information about typical floating roof and typical cone roof installation methods see page 6.

FleXIBle PIPe INStallatION aND MOuNtINg reFereNCeS

1 in. NPTadjustable fitting

Tank flange(provided by customer)

Bottom-fixing weight, magnetor hook

Stainless-steelflexible pipe

Interface float

Riser

Product float

127 mm(5 in.)

210 mm(8.25 in.) max.

121 mm(4.75 in.) O.D.

traNSMItter INaCtIVe ZONeS

<25 ft. 76 mm 3 in.

<40 ft. 96.5 mm 3.8 in.

<60 ft. 119 mm 4.7 in.

TotalInactive Zone

TransmitterInactive Zone

See Table

Level 1 Float(Order Separately)

Level 2 Float(Order Separately)

Order length3 m (120 in.) to18 m (720 in.)

Outer Pipe,Constructed of 316L SS

Flexible Pipe,22 mm (0.875 in.)

O.D.

305 mm(12 in.)

Threaded 1 in. NPT - Compression Fitting, Male

Tank Flange

686 mm(27 in.)

OptionalWelded RF Flange

76 mm(3 in.)

2 in.(typ.)

127 mm(5 in.)

Bottom-FixingHook

DT Custom PositionsModbus

DDA & F.F.

12

11

10

9

8

7

6

5

4

3

2

1

5

4

3

2

1

Bottom-Fixing Weight Bottom-Fixing Magnet

Notes:

Drawings are for reference only. 1. Contact factory for engineering drawings.2. Application worksheets are available at www.mtssensors.com.3.

Page 6: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

M-Series Model MR Liquid-Level Transmitter, Digital Output - Product Specification, 550784 F MTS Sensors6

typical tank mounting and floating roof and cone roof installations

Illustrated below are tank mounting, floating roof installation, floating roof and cone roof methods.

tyPICal taNk MOuNtINg Single entry into tank �easy to install �Product and interface level measurement �Single and multi-point temperature �average temperature of submerged Dts �Modbus and F � OuNDatION™ fieldbus outputs

provide gross volumes, net volumes, mass and alarms

DDa output provides product and interface, � level and temperature

Note:

Drawings are for reference only. Contact factory for engineering drawings.

Product level

3/4 in. NPTadjustable fitting95 mm (3.75 in.)

(typical)

Vessel flange

Vessel bottom

Float magnet

Interface

127 mm(5 in.)

210 mm(8.25 in.) max.

121 mm (4.75 in.) O.D.

Order length

Optional stop collarE-ring float clip

eXterNal FlOatINg rOOF INStallatION

Gauge welland cover

Productlevel

Customerwiringconduit

Customer providedtank-gauge bracket

1 in. NPT

Float

Flex pipe

Bottom fixingmagnet or weight

Optional BS&Wfloat

Floating roof

127 mm (5 in.)

210 mm(8.25 in.)max.

121 mm(4.75 in.) O.D.

MTS

tyPICal FIXeD FlOatINg rOOF INStallatION

Product level

Customerwiringconduit

Float

Flex pipe

Bottom-fixingmagnet or weight

Tank top

Blind-flange drilledfor 1 in. NPTExisting tank riser

127 mm (5 in.) 210 mm(8.25 in.) max.

121 mm(4.75 in.) O.D.

MTS

Page 7: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

M-Series Model MG Liquid-Level Transmitter, Digital Output - Product Specification, 550784 FMTS Sensors 7

Interface and enclosure options

MtS DDa PrOtOCOl

MTS DDA proprietary protocol IS developed for use in intrinsically safe areas. The M-Series Model MG transmitter is backwards compatible with existing IS installations of D8/D9 and LDF MTS sensors, as long as the total number of transmitters does not exceed 8 per monitor. The DDA protocol allows the transmitter to be in a low power or “idle” mode while not pro cessing commands. This protocol allows for level, interface and temperature data to be output from the transmitter.

MODBuS rtu PrOtOCOl

The Modbus RTU protocol is available for use in explosion-proof areas and allows the M-Series Model MG transmitter to communicate level, temperature and volume information directly from the transmitter head.

FOuNDatION™ FIelDBuS PrOtOCOl

FOUNDATION™ fieldbus H1 is intended primarily for process control, field-level interface and device integration. Running at 31.25 kbit/s, the technology interconnects field networked devices such as transmitters and actuators. FOUNDATION™ fieldbus H1 is designed to support intrinsi-cally safe (I.S.) applications and operate on an existing twisted pair instrument cabling with power and signal on the same wire.

eNClOSure OPtIONS

Note:

Drawings are for reference only. Contact factory for engineering drawings.

NeMa tyPe 4X eNClOSure

Top View

123 mm(4.85 in.) O.D.

81 mm(3.19 in.)

152 mm(6 in.)

Factory supplied cableconnected to internalterminal strips

SINgle CaVIty eNClOSure

123 mm(4.84 in.)

3/4 in. NPTconduit access

127 mm(5 in.)

210 mm(8.25 in.) max.121 mm

(4.75 in.) O.D.

Dual CaVIty eNClOSure

127 mm(5 in.)

210 mm(8.25 in.) max.

121 mm(4.75 in.)

O.D.

177 mm(6.95 in.)

81 mm(3.18 in.)

3/4 in. NPTconduit access

Page 8: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

M-Series Model MR Liquid-Level Transmitter, Digital Output - Product Specification, 550784 F MTS Sensors8

M-Series Model Mg, Digital transmitter - Ordering information

Use the guide below to build a model number for the M-Series Model MG transmitter. A model number is required to place an order and is helpful in identifying installed products. For standard accessory information, refer to page 9 or the Liquid-Level Accessories Catalog (part no. 551103) for additional information.

traNSMItter MODel = M 1

M = Magnetostrictive transmitter

tyPe = g 2

g = Digital output level transmitter

INPut POWer = a 3

a = 24 Vdc

OutPut POWer = 4M = Modbus RTU data format t = Modbus sight glass

D = MTS DDA

F = FOUNDATION™ fieldbus S = FOUNDATION™ fieldbus sight glassHOuSINg tyPe = 5

3 = NEMA Type 4X, 316L stainless steel with NPT and internal terminal blocks (Intrinsically safe only)

C = Dual cavity (explosion-proof and intrinsically safe)

B = Single cavity (explosion-proof and intrinsically safe) l = NEMA Type 4X, 316L w/6-pin connector

eleCtrONICS MOuNtINg = 61 = Integral electronics

traNSMItter PIPe = 7B = Industrial end-plug with stop collar F = Sanitary, drain-in-place, no hole, DN

C = Sanitary, T-bar, TB M = Flexible w/bottom fixing hook (stainless steel only)

D = Sanitary, drain-in-place, DP N = Flexible w/bottom fixing weight (stainless steel only)

e = Sanitary, clean-in-place, CP P = Flexible w/bottom fixing magnet (stainless steel only)

MaterIalS OF CONStruCtION (WetteD PartS) = 8Note: contact factory for other materials

1 = 316L stainless steel a = Teflon2 = Electropolished 316L stainless steel Ra 15 C = CRN Approved

PrOCeSS CONNeCtION tyPe = 91 = NPT, Adjustable 4 = Sanitary, welded5 = Sanitary, adjustable 6 = 150 lbs. welded RF flange

7 = 300 lbs. Welded RF flange 8 = 600 lbs. welded RF flange

X = None

PrOCeSS CONNeCtION SIZe = 10a = ¾ in. (NPT only) Rigid pipe only B = 1 in. (NPT only) Flex pipe only

C = 1½ in. D = 2 in.

e = 2½ in. F = 3 in.

g = 4 in. H = 5 in. (except sanitary)

J = 6 in. X = None

teMPerature (DIgItal tHerMOMeterS) = 110 = None 1 = One DT, 203 mm (8 in.) when order length is less than

914 mm (36 in.)2 = One DT, customer defined position

(if this option is selected, option 18 E must also be selected)5 = Five DTs, evenly spaced as API

k = Twelve DTs, evenly spaced per API 6 = Five DTs, customer defined position (if this option is selected, option 18 E must also be selected)

l = Twelve DTs, customer defined position

uNIt OF MeaSureMeNt = 12M = Metric (millimeters) Encode length in millimeters if using metric

(XXXXX mm)u = US Customary (inches) Encode length in inches if

ordering in US Customary (XXX.XX in.)

leNgtH _ _ _ _ _ _ = 13-17

= Order length based on unit of measurement - Rigid transmitter pipe length;\: 508 mm (20 in.) to 7620 mm (300 in.) and Flexible transmitter pipe length: 3050 mm (120 in.) to 22000 mm (866 in.)

SPeCIal = 18S = Standard product e = Engineering special

(not affecting agency controlled parts or features)

Page 9: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

M-Series Model MG Liquid-Level Transmitter, Digital Output - Product Specification, 550784 FMTS Sensors 9

Model Mg - accessories overview, floats

Product & Dimensions Pressure temp. Magnet Offset type Specific

gravity Material Weight Offset

Part Number

StaNDarD rIgID FlOat18 mm(0.70 in.) dia.

47 mm(1.85 in.) dia.

76.5 mm(3.01 in.) 29.3 bar

(425 psi)149 °C (300 °F) No Product

0.65 SS No 251981-1

0.67 SS Yes 251981-2*

0.68 Hastelloy C No 251981-3

0.71 Hastelloy C Yes 251981-4*

CrItICal SerVICe FlOat

18 mm (0.7 in.) dia.

89 mm (3.5 in.) dia.

91 mm(3.57 in.) 29.3 bar

(425 psi)149 °C (300 °F) No Critical

service

0.43 SS No 251469-1

0.45 SS Yes 251469-2*

StaNDarD SaNItary FlOat18 mm(0.7 in.) dia.

47 mm(1.85 in.) dia.

Centerline of magnet

89 mm(3.5 in.)

108 mm(4.25 in.)

10.3 bar(150 psi)

149 °C (300 °F) Yes Sanitary 0.66

SS200 Grit/

Ra 25

No 401513-1

Yes 401513-2*

SS240 Grit/

Ra 15

No 401513-3*

Yes 401513-4*

StaNDarD FleX FlOat

Magnet

28 mm(1.10 in.)

130 mm(5.11 in.)

127 mm(4.98 in.)

63 mm(2.49 in.)

37.9 bar(550 psi)

149 °C (300 °F) No

Product0.44 SS No 250709-1*

0.52 Hastelloy C No 250709-3*

Interface

0.90 - 0.96SS No 250714-1*

Hastelloy C No 250714-3*

1.03 - 1.10SS No 250855-1*

Hastelloy C No 250855-3*

Notes: *Call the factory for specific lead times. Typical lead time exceeds lead time of the sensor.1. Drawing contained in this document are for reference only. Contact the factory for engineering drawings.2.

Page 10: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

M-Series Model MR Liquid-Level Transmitter, Digital Output - Product Specification, 550784 F MTS Sensors

Model Mg - accessories overview, float options (for all applications)

Product & Dimensions Pressure temp. Magnet Offset

Specific gravity

Material/type

Weight Offset

Part Number

lONg-gauge FleX FlOatS

28 mm(1.10 in.) dia.

91.5 mm(3.6 in.) dia.

87.5 mm(3.44 in.)

44 mm

(1.72 in.)

C MagnetL29.3 bar(425 psi)

149 °C (300 °F) No

0.54 SS No 251223-1

0.65 Hastelloy C No 251223-3*

130 mm(5.11 in.)

127 mm(4.98 in.)

116 mm(4.55 in.)

28 mm (1.1 in.)

CL Magnet

37.9 bar(550 psi)

149 °C (300 °F) Yes 0.44 SS

No 201248-1

Yes 201248-2*

17.2 bar(250 psi)

149 °C (300 °F) No

0.44 SS

No 251426-1*

Yes 251426-2*

0.47 Hastelloy C

No 251426-3*

Yes 251426-4*

Notes:

Be sure that the float specific gravity is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 1. For interface measurement: A minimum of 0.05 specific gravity differential is required between the upper and lower liquids. 2. When the magnet is not shown, the magnet is positioned at the center line of float. 3. Offset weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the 4.

transmitter tube at all times. The offset option is required for installations that must conform to PTB standards.*Call the factory for specific lead times. Typical lead time exceeds lead time of the sensor.5. Drawing contained in this document are for reference only. Contact the factory for engineering drawings.6.

10

48 mm(1.9 in.) dia.

6.95 in.(00.0 mm)178 mm

(7 in.)

178 mm(7 in.)

Page 11: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

M-Series Model MG Liquid-Level Transmitter, Digital Output - Product Specification, 550784 FMTS Sensors 11

Nitrophyl product and interface float options

Notes:

Floats 201649-1 and 201650-1 may be used with propane, butane, and liquefied petroleum gas. Precautions should be taken to ensure that no other 1. contaminant’s are present in these liquids, which may not be compatible with Nitrophyl.

When magnet is not shown, the magnet is positioned at the centerline of the float.2.

Product & Dimensions Pressure temp. Magnet Offset

Specific gravity

Material/type

Weight Offset

Part Number

NItrOPHyl PrODuCt / INterFaCe FlOatS

Stainlesscover

Stainlessfloat post

Nitrophyl base

168 mm(6.61 in.)

C Magnet 152 mm(5.99 in.)

152.5 mm(6.00 in.) dia.

30 mm(1.19 in.)

I.D.

L

17.2 bar(250 psi) 104 °C

(220 °F)Yes

0.65 Nitrophyl/Product No 252998*

0.90 -0.96

Nitrophyl/Interface

No 252999*

Page 12: M-Series Model MG Transmitter with Digital Output€¦ · The M-Series Model MG transmitter satisfies the demand ... are communicated via a 4-wire multi-drop power ... (contact factory

uNIteD StateSMtS Systems CorporationSensors Division

3001 Sheldon DriveCary, NC 27513Tel: (800) 633-7609Fax: (919) 677-0200 (800) [email protected]

gerMaNyMtS Sensor technologiegmbH & Co. kg

Auf dem Schüffel 9D - 58513 LüdenscheidTel: +49 / 23 51 / 95 87-0Fax: +49 / 23 51 / 56 [email protected]

Part Number: 08-08, 03-09 550784 revision FMTS, Level Plus and Temposonics, are registered trademarks of MTS Systems Corporation.

All other trademarks are the property of their respective owners.All Temposonics sensors are covered by US patent number 5,545,984. Additional patents are pending.

Printed in USA. Copyright © 2008 MTS Systems Corporation. All Rights Reserved in all media.

JaPaNMtS Sensors technologyCorporation

Ushikubo Bldg.737 Aihara-cho, Machida-shiTokyo 194-0211, JapanTel: +81 (42) 775 / 3838Fax: +81 (42) 775 / [email protected]

SENSORS

®

FMAPPROVED

accessories overview

aCCeSSOrIeS PrODuCt DeSCrIPtIONS MtS Part NO.

M-SerIeS PC SetuP SOFtWare

M-Series Modbus setup software, shipped with the sensor, will allow the setup and calibra-tion of M-Series digital sensors. The software communicates via RS-485 to RS-232 adapter. 625051

M-Series Modbus setup software, shipped with the sensor, will allow the setup and calibration of M-Series digital sensors. 625052

RS-485 to RS-232 adapter 380075

M-Series Digital PC setup software (DDA) 625053

H100 lIQuID-leVel Ht100 HaND HelD terMINal (DDa ONly)

The liquid-level HT100 is a convenient and cost-effective tool for supporting MTS Direct Digital Access (DDA) sensors, side tank indicators and tank moni tors in the field. The hand-held microprocessor-based unit performs all the operations necessary for setting up, troubleshooting and maintaining an MTS DDA tank gauging system. Using the HT100 allows users to program and per form diagnostics on-site, saving time and money.

251259

Disposable RS-485 Surge protector, go to www.bb-elec.com (part no. 485FPP) 370542

Belden cable, 4-wire RS-485 cable, www.belden.com 8162

MagNet aND WeIgHt aSSeMBlIeS

51 mm(2 in.)

76 mm(3 in.)

150 lb. pull for LDF long sensor and M-Series sensors. 560604

51 mm(2 in.)

127 mm(5 in.)

Standard 11 lb. weight for M-Series sensors. 401059

A

A

191 mm(7.5 in.) dia.

165 mm(6.5 in.) dia.

Section A-A

84 mm(3.3 in.)

3 mm(0.13 in.)

16 mm(0.63 in.) Low liftoff 11 lb. weight assembly Use with float

part no. 252998/252999 402364

Label, 3A Sanitary 400868