level instruments - o-verall
TRANSCRIPT
LEVEL INSTRUMENTS
TRANSMITTERS
SWITCHES
INDICATORS
LEVEL TRANSMITTERS CAPACITANCE TYPE
A. APPLICABLE MODELS
Electronic
B. TRANSMITTERS
Type
Analog ; ModBus
Supply
24 V dc
Output signal
4 - 20 mA (two wire system) ; EIA RS-485 4 - A
EIA RS-485
Integral indicator
LCD
Measuring range
100 - 3500 mm.
Max operating pressure
15 bar
Process connection
Flanged or threaded
Ingress protection
IP65
Wetted parts
SS 316 ; SS 304
Housing
Cast aluminum
Dielectric compensation
if required
DIFF. PRESSURE LEVEL TRANSMITTERS
A. APPLICABLE MODELS
Electronic
Wireless
Pneumatic
B. ELECTRONIC TRANSMITTERS
Type
SMART with HART protocoll SMART c
Supply
24 V dc
Output signal
4 - 20 mA (two wire system) 4 - A
Accuracy
+ / - 0,25 %
Integral indicator
LCD
Zero suppression and elevation
if required
External zero and span calibration
Adjustable damping
Diaphragm seal with capillary
if required
C. PNEUMATIC TRANSMITTERS
Type
Force balance
Supply
20 psig
Output signal
3 - 15 psig
Accuracy
+ / - 0,5 %
Zero suppression and elevation
if required
Output signal indicator
Diaphragm seal with capillary
if required
D. PROTECTION DEGREE
IP55 (according to IEC-529) IP IEC-529)
E. CONNECTIONS
Process 1/2" NPT
Electrical 1/2" NPT
Pneumatic 1/4" NPT
F. CONSTRUCTION CHARACTERISTICS
Wetted parts AISI 316
Case
Manufacturer std. or AISI 316
AISI 316
Capillary and armour When required AISI 316
AISI 316
NACE MR-0175 When required
LEVEL GAUGE GLASSES GENERAL REQUIREMENTS
A. APPLICABLE MODELS
Reflex
Transparent
Magnetic
Transparent type shall be used for interface indication; when color identification is required or when glass protection is necessary.
B. DIMENSIONS
Use of gauges with max. center to center of 1600 mm. Is suggested. Specify more complementary gauges for longer visibility.
C. CONNECTIONS
Flanged 1" or 2"
D. CONNECTIONS LOCATION
Top / bottom
Side / side
Side / bottom
E. GAUGE COCKS
2 cut-off valves 2
1 drain valve
Vent connection
Drain connection
F. ACCESSORIES
Anti-frosting protection (low temperature)
1/2" NPT-F
Protection shields
3/4" NPT-F
Internal or external heating or cooling
Lighting (transparent type) protection degree IP55 (IEC-529) IP55 (IEC-529)
Certified electrical protection mode
G.
Body
Glass
Glass gasket
Manufacturer std. or PTFE PTFE
Cocks (shut-off & drain)
Internal AISI 316
NACE MR-0175
Process connections size & rating
LEVEL TRANSMITTERS RADAR TYPE
A. APPLICABLE MODELS
Electronic Wireless
B. TRANSMITTERS
Type
HART protocol
Supply
24 V dc
Output signal
4 - 20 mA (two wire system) 4-
Frequency of measuring signal
24 GHz
Integral indicator
LCD
Measuring range
0,2 - 23 meters 0,2-
Minimum beam angle
11 °
Resolution
1 mm
Measuring frequency
60 sec.
Antenna diameter
38-75 mm 38-
Antenna material
Stainless Steel
Max operating pressure
35 bar
Process connection
Flanged or threaded
Ingress protection
IP67
LEVEL SWITCHES GENERAL REQUIREMENTS
A. APPLICABLE MODELS
Float
Displacer
B. MOUNTING
Internal
Side or top mounted
For internal type top mounted, in case of turbolence inside the vessel the float shall be guided with extension pipe 4" size.
External
Side / bottom
Side / side
C. PROTECTION DEGREE
IP55 (according to IEC-529) IP IEC-529)
D. DIFFERENTIAL
Fixed
E. ELECTRICAL SWITCH
Sealed type
1 or 2 SPDT contact 1 2 SPDT
Min. Rating
2A at 24 V dc
5A at 250 V ac
F.
PNEUMATIC SWITCH
Three ways valve
Supply pressure
0 - 20 psig
Output
0 - 20 psig
G. CONNECTIONS
Process
4" flanged for top installation 4"
1" flanged for external installation 1"
for external side / side installation drain connection 1" NPT-F
/
1" NPT-F
complete with plug shall be provided
Electrical
1/2" NPT-F
H. CONSTRUCTION CHARACTERISTICS
Wetted parts
AISI 316
Case
Body
carbon
LEVEL TRANSMITTERS AND CONTROLLER
A. APPLICABLE MODELS
Electronic
Pneumatic
B. ELECTRONIC TYPE
Supply
24 V dc
Output signal
4-20 mA (two wire system) 4-
Sensing element
Torque / floating tube
Accuracy
+ / - 1 %
Integral indicator
LCD
External zero and span calibration
C. PNEUMATIC TYPE
Supply
20 psig
Output signal
3 - 15 psig
Sensing element
Torque / floating tube
Accuracy
+ / - 1 %
Output signal indicator
D. PROTECTION DEGREE
IP55 (according to IEC-529) IP IEC-529)
E. Process
4" flanged internal
mounting
2" flanged external mounting
Electrical
1/2" NPT
Pneumatic
1/4" NPT
Drain and vent connections with plug
F. CONSTRUCTION CHARACTERISTICS
Internal
Top mounted
For internal type top mounted, in case of turbolence inside the vessel the float shall be guided with extension pipe 4" size.
External
Side / bottom
Side / side
Top / bottom
Top / side
G.
IDENTIFICATION LABEL
Permanent fixing and indelible writings with the following informations:
Manufacturer
Serial number
Model number
Max.pressure / temperature
Protection degree
Wetted parts material
Displacer length
Process connections dimensions and rating
MAGNETIC LEVEL INDICATOR / TRANSMITTER
A. APPLICABLE MODELS
Side / side connections
B. ELECTRONIC TRANSMITTERS
Type
SMART with HART protocoll SMART c
Supply
24 V dc
Output signal
4 - 20 mA (two wire system)
4 - A Accuracy
+ / - 0,01 %
Integral indicator
LCD
Electrical connections
1/2" NPT
C. PROTECTION DEGREE
IP 40
D. PROCESS CONNECTIONS
FLANGED : 1"
RATING : 150 - 2500#
16 - 400 bar 16 -
THREADED : 2"
E. CONSTRUCTION CHARACTERISTICS
Wetted parts
AISI 316 L
Body
AISI 316
NACE MR-0175 When required