jila, nist & university of colorado€¦ · jila, nist & university of colorado optical...

29
MURI 25 th Birthday, Washington DC, Nov. 9, 2011 Jun Ye JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body quantum systems Optical atomic clocks

Upload: others

Post on 02-Jun-2020

24 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

MURI 25th Birthday, Washington DC, Nov. 9, 2011

Jun Ye

JILA, NIST & University of Colorado

Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light

Many-body quantum systems Optical atomic clocks

Page 2: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

(Peter Reynolds) ONR/MURI, 2001

Optical Clocks: Fundamental aspects,

practical issues and enabling technology

Bergquist, Cundiff, Delfyett, Diels, Gibble, Hall, Hollberg, Jones,

Kapteyn, Kimble, Ye (PI)

JILA/Colorado, Caltech, Central Florida, New Mexico, NIST, Penn State

Outside Collaborations

MIT (the other MURI team)

Page 3: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Clocks are everywhere

Fiber-Laser

Comb

Transmit Fiber

Length

Metrology

Fundamental and Applied Science

Tele-

communications Standards for

Industry

ESA satellite to

satellite comm

Space exploration, Defense & Homeland security

Page 4: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Spectrum in optical frequency synthesis

Log

Frequency

(Hz)

107

1010

1011

1012

1013

1014

1015

Crystal oscillator

(rf timer)

Cs

HCOOH HCN

CH3OH

H2O CO2 OsO4

CH4

Visible Molecular

overtone Rb, Cs

I2 Ca H, Hg+

Laser

Microwave

oscillators,

Klystrons,

etc.

MIM or

Schottky

diode

W-Si

mwave

diode

Page 5: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Spectrum in optical frequency synthesis

Log

Frequency

(Hz)

107

1010

1011

1012

1013

1014

1015

Crystal oscillator

(rf timer)

Cs

HCOOH HCN

CH3OH

H2O CO2 OsO4

CH4

Visible Molecular

overtone Rb, Cs

I2 Ca H, Hg+

Laser

Microwave

oscillators,

Klystrons,

etc.

MIM or

Schottky

diode

W-Si

mwave

diode

Harmonic frequency chains – NRC; PTB; …

Page 6: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

An Optical Frequency Chain NBS (NIST): measurement of speed of light, 1972

J. Wells

Hall & Ye, “NIST 100th birthday”, Optics & Photonics News 12, 44 (2001).

K. Evenson

Page 7: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

The age of atomic clocks - Chasing the SPEED!

Faster oscillations More cycles Smaller errors

Precision: 1 000 000 000 000 000 ± 1

Light ripples: 1015 cycles per second, & we count every one

~1 bacteria length out of the Sun-Earth distance

Earth Sun bacteria

Page 8: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Long-term optical coherence ( 1 s)

-6 -4 -2 0 2 4 6 8 10

0

1

2

3

Lin

ear

Sig

na

l (a

. u

.) Optical

linewidth:

250 mHz

Hz

Ludlow et al., Opt. Lett. 32, 641 (2007).

Laser 2

Cavity 2 Cavity 1

Laser 1

Beat between two independent lasers

10 s

Page 9: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

A rainbow spectrum with 10-19 precision

Optical

freq. Radio

freq.

Hall and Hänsch, 2005 Nobel Prize Optical frequency comb

Cundiff and Ye, Rev. Mod. Phys. 75, 325 (2003).

Optical coherence time > 1 s (<10-15), anywhere in the visible Schibli et al., Nature Photonics 2, 355 (2008).

Page 10: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

A rainbow spectrum with 10-19 precision

Optical

freq. Radio

freq.

Hall and Hänsch, 2005 Nobel Prize Optical frequency comb

Cundiff and Ye, Rev. Mod. Phys. 75, 325 (2003).

-1.0 -0.5 0.0 0.5 1.0

-1.0

-0.5

0.0

0.5

1.0

Data: TEK00000_B

Model: user1

Weighting:

Y No weighting

Chi^2/DoF = 6.43322

R^2 = -0.64257

a0 2.87 ±0

a1 4.8 ±0

a2 93.63961 ±0.00497

a3 10.3 ±0

b -0.07 ±0

sign

al a

mpl

itude

(arb

. uni

ts)

time (s)

Counting the light ripple

Optical coherence time > 1 s (<10-15), anywhere in the visible Schibli et al., Nature Photonics 2, 355 (2008).

Page 11: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

A rainbow spectrum with 10-19 precision

Optical

freq. Radio

freq.

Hall and Hänsch, 2005 Nobel Prize Optical frequency comb

Cundiff and Ye, Rev. Mod. Phys. 75, 325 (2003).

Optical coherence time > 1 s (<10-15), anywhere in the visible Schibli et al., Nature Photonics 2, 355 (2008).

Radio frequency Light

106 :1 Reduction Gear

Light

Page 12: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Optical atomic clocks

Ultrastable laser

optical comb optical frequency counter

Sr atoms

Oscillator

Counter

Page 13: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Optical lattice – a many-body quantum system

Engineered quantum states eliminating motional effects

Separation of internal and external degrees of freedom

Isolation from environment

Long coherence times

Large atom numbers to increase signal and accuracy

1D L

attice

2D Lattice

3D

Science 331, 1043 (2011)

Page 14: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

JILA Sr atomic clock

10, 000, 000, 000, 000, 000 ± 1 (10-16)

Science 314, 1430 (2006); Science 319, 1805 (2008); Science 320, 1734 (2008);

Science 324, 360 (2009); Science 331, 1043 (2011).

Page 15: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

JILA Sr atomic clock

10, 000, 000, 000, 000, 000 ± 1 (10-16)

1 10 100 1000 1000010

-17

10-16

10-15

tota

l devia

tion

time (s)

Sr – Yb standards

Ludlow / Time & Freq.

Definition of SI “SECOND”

Science 314, 1430 (2006); Science 319, 1805 (2008); Science 320, 1734 (2008);

Science 324, 360 (2009); Science 331, 1043 (2011).

Page 16: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Precise distribution of ultra-stable signals

Foreman, Holman, Hudson, Jones, and Ye, Cover Review, Rev. Sci. Instrum. 78, 021101 (2007).

100 km fiber: 1 x 10-17 @ 1 s; 1 Hz optical linewidth; 0.1 fs jitter (20 MHz BW)

SYRTE, NIST, …

Page 17: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Phase-coherent radiations – IR to XUV - Spectroscopy & Quantum Control

Phase-coherent synthesis of the electromagnetic spectrum

Ar: 82 nm

2170 2200 2230 2260

-1

-0.5

0

0.5

1

x 10-3

HITRAN database

2700 2800 2900 3000

-1

0

1

x 10-3

NWIR database

2850 2900 2950 3000 3050 3100

-5

0

5

x 10-4

NWIR database

2900 2950 3000 3050 3100 3150

-2

0

2

x 10-4

HITRAN database

2900 2950 3000 3050 3100 3150

-5

0

5

x 10-5

NWIR database

3300 3350 3400 3450 3500

-5

0

5

x 10-4

HITRAN database

N2O, 9 ppm, 100 torr, 0.014 cm-1 (a) H2CO, 58 ppm, 600 torr, 0.014 cm-1 (b)

C2H6, 11 ppm, 600 torr, 0.096 cm-1 (c) CH4, 10 ppm, 100 torr, 0.0056 cm-1 (d)

C5H8, 16 ppm, 600 torr, 0.058 cm-1 (e) N2O, 142 ppm, 600 torr, 0.026 cm-1 (f )

Ab

sorb

an

ce (cm

-1)

Ab

sorb

an

ce (cm

-1)

Ab

sorb

an

ce (cm

-1)

Wavenumber (cm-1) Wavenumber (cm

-1)

cm-1

Nature, in press (2011).

Extreme Ultraviolet

Page 18: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Phase-coherent radiations – IR to XUV - Spectroscopy & Quantum Control

Phase-coherent synthesis of the electromagnetic spectrum

Ar: 82 nm

2170 2200 2230 2260

-1

-0.5

0

0.5

1

x 10-3

HITRAN database

2700 2800 2900 3000

-1

0

1

x 10-3

NWIR database

2850 2900 2950 3000 3050 3100

-5

0

5

x 10-4

NWIR database

2900 2950 3000 3050 3100 3150

-2

0

2

x 10-4

HITRAN database

2900 2950 3000 3050 3100 3150

-5

0

5

x 10-5

NWIR database

3300 3350 3400 3450 3500

-5

0

5

x 10-4

HITRAN database

N2O, 9 ppm, 100 torr, 0.014 cm-1 (a) H2CO, 58 ppm, 600 torr, 0.014 cm-1 (b)

C2H6, 11 ppm, 600 torr, 0.096 cm-1 (c) CH4, 10 ppm, 100 torr, 0.0056 cm-1 (d)

C5H8, 16 ppm, 600 torr, 0.058 cm-1 (e) N2O, 142 ppm, 600 torr, 0.026 cm-1 (f )

Ab

sorb

an

ce (cm

-1)

Ab

sorb

an

ce (cm

-1)

Ab

sorb

an

ce (cm

-1)

Wavenumber (cm-1) Wavenumber (cm

-1)

cm-1

Nature, in press (2011).

Extreme Ultraviolet

Page 19: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Thorpe et al., Science 311, 1595 (2006). Chem. Rev. 2010; Phys. Rev. Lett. 2011.

Direct Frequency Comb Spectroscopy

Page 20: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Bohn Jin Ye

Eyler Gould

Stwalley

Yelin (PI)

Chuang Côté

DeMille

Kotochigova

Ketterle Doyle

Demler

AFOSR MURI - Cold Molecules

(2009)

Page 21: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Ultracold gases

Precise control of a quantum system

applications:

quantum computing

atomic clocks

precision measurements

cold-atom-based sensors

Control: A tool for understanding complexity.

Build up strongly correlated many-body quantum systems

• Fermi superfluidity

• fermions or bosons in an optical lattice

Page 22: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Extend our capability to control quantum systems

What’s new (compared to ultracold atoms)?

New internal degrees of freedom

vibration, rotation

Chemistry

Long-range interactions

Why polar molecules?

E Exotic

quantum

matter

Page 23: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Atom vs. molecule

T = 100 nK

N = 106 atoms

n = 1013 cm-3

Bose-Einstein Condensation

1995

Molecules:

T = 100 mK, n = 106 cm-3

Page 24: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Molecules are complex!

6000 K

0.1 K 38 μK 100 K

10 orders of magnitude

1010 108 105 102 1

200 nK

Ultracold molecules: The challenge

vibration

binding

energy

rotation hyperfine translation

1 μK

trap depth

Page 25: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Quantum gas of polar molecules

40K Fermions 87Rb Bosons

Science 322, 231 (2008)

Science 327, 853 (2010) Nature 464, 1324 (2010)

Debbie Jin J. Ye

Page 26: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Light provides the answer

Photons carry away the energy!

Laser light

Laser light

Page 27: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Chemistry near absolute zero (1) Molecules behave like waves

(2) Angular momentum is quantized

(3) Quantum statistics matter

Fermions c L = 1, p-wave collisions

s p d

0 1ħ 2ħ

Page 28: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

New quantum phases and dynamics

E

E

• Correlated Fermi pairs

• Bi-layer Bose condensation?

• Super solids?

• … …

Zoller, Demler, Santos, … …

Revolution ongoing !

Page 29: JILA, NIST & University of Colorado€¦ · JILA, NIST & University of Colorado Optical Atomic Clock & Absolute-Zero Chemistry – Probing Quantum Matter with Precision Light Many-body

Over the years … F. Adler (NIST) S. Blatt (Harvard) J. Bochinski (Faculty, NC State) M. Boyd (AO Sense, industry) G. Campbell (Faculty, U. Maryland) L. Chen (Faculty, WIPM) S. Foreman (Stanford U.) K. Holman (Staff, Lincoln Lab) E. Hudson (Faculty, UCLA) T. Ido (Senior staff, Tokyo NICT) D. Jones (Faculty, UBC) J. Jones (Faculty, U. Arizona) Y. Lin (Staff, Nat. Inst. Metrology) T. Loftus (AO Sense, industry) H. Lewandowski (Faculty, U. Colorado) A. Ludlow (Scientist, NIST) K. Moll (Precision Photon., industry) M. Notcutt (ATF, industry)

B. Lev (Faculty, Stanford U.) S. Ospelkaus (Faculty, U. Hannover) A. Pe’er (Faculty, Bar-Ilan U.) B. Sawyer (NIST) T. Schibli (Faculty, U. Colorado) M. Stowe (Staff, Lincoln Lab) M. Thorpe (NIST) D. Wang (Faculty, U. Hong Kong) X. Xu (Faculty, ECNU) T. Yoon (Faculty, Korea Nat. U.) T. Zanon (Faculty, Univ. Paris) T. Zelevinsky (Faculty, Columbia U.) & current group members … …

http://JILA.Colorado.edu/YeLabs