CA9500430 Canadian Fusion Fuels Technology Project ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC DISTILLATION TESTS CFFTP G-9504 January, 1995 K. Woodall 1 , J. Robins 1 , D. Bellamy 1 , R. Gnoyke 1 , S. Sood 2 , C. Fong 2 , and P. Gierszewski 3 Ontario Hydro Technologies 1 , Ontario Hydro Nuclear 2 , Canadian Fusion Fuels Technology Project 3 CFFTP GENERAL

Upload: others

Post on 03-Oct-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

CA9500430

Canadian Fusion FuelsTechnology Project

ITER TASK T48 (1994)LOW-INVENTORY CRYOGENIC DISTILLATION TESTS

CFFTP G-9504January, 1995

K. Woodall1, J. Robins1, D. Bellamy1, R. Gnoyke1, S. Sood2, C. Fong2,and P. Gierszewski3

Ontario Hydro Technologies1, Ontario Hydro Nuclear2, Canadian Fusion FuelsTechnology Project3

CFFTP GENERAL

Page 2: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

The Canadian Fusion Fuels Technology Project represents part of Canada's overall effort in fusion energyresearch. The focus for CFFTP is tritium technology and remote handling. The Project is funded by theGovernment of Canada and Ontario Hydro Technologies. Ontario Hydro Technologies administers theProject.

Page 3: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

ITER TASK T48 (1994)LOW-INVENTORY CRYOGENIC DISTILLATION TESTS

CFFTP G-9504January, 1995

K. Woodall1, J. Robins1, D. Bellamy1, R. Gnoyke1, S. Sood2, C. Fong2,and P. Gierszewski3

Ontario Hydro Technologies1, Ontario Hydro Nuclear2, Canadian Fusion FuelsTechnology Project3

'C-Copyright Ontario Hydro, Canada, 1995. Inquiries about copyright andreproduction should be addressed to:

Manager, CFFTP2700 Lakeshore Road WestMississauga, Ontario CanadaL5J 1K3

CFFTP GENERAL

Page 4: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

ITER TASK T48 (1994):LOW-INVENTORY CRYOGENIC DISTILLATION TESTS

TABLE OF CONTENTS

Section Page

1. Executive Summary 1

2. Task Objectives 2

3. Theory 2

4. Experiment Description 3

5. Results 4

6. Discussion 6

7. References 6

Page 5: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

ITER TASK 748(1994):LOW-INVENTORY CRYOGENIC DISTILLATION TESTS

1. EXECUTIVE SUMMARY

Previous work at Ontario Hydro Technologies (OHT) had shown that small cryogenic columnscould be stably controlled and designed to much lower inventories than had been previouslythought possible. Among the results were measurements of Height-of-Equivalent-Theoretical-Plate (HETP) versus holdup for Heli-Pak A and B in columns up to 20 mm diameter. ITERcryogenic distillation column designs suggest that the final high-tritium columns could be 30-70mm diameter. The objective of this ITER task was to design and construct a column section fordemonstration of scale-up of low inventory cryogenic distillation.

The experiments were to be carried out in an upgraded Cryogenics Distillation Laboratory atOHT, in the facility used for previous low-inventory column tests. The ITER scaled-up testsystem has the following characteristics: 55 W condenser capacity; 30-mm diameter columnloaded with Helipak B; 1500 mm packed height.

The first task was to design and build the scaled-up test facility. Most of the changes werestraightforward. In order to reduce costs, it was necessary to use existing 30-35 W heliumrefrigerators. Therefore, to provide 60-W duty to the scaled-up column, the two refrigerators hadto be well-coupled thermally, but not mechanically, since the refrigerator cold heads have verythin shells. The solution was to attach the column firmly to one cold head, and indirectly to anadjacent cold head through flexible copper braid. Several iterations were required to obtain thedesired good heat transfer with flexible mechanical connection. This facility is now operationaland ready to begin measurements on the 30-mm column.

Also during 1994, the Princeton Tritium Processing System (TPS) was installed andcommissioned. The results from this experience are relevant to the ITER distillation system.

The implications of the 1994 results are:- Staged diffusers provide efficient, clean and low-inventory separation of hydrogen suitable for

cryogenic distillation feed;- Column wetting procedures can be applied to multicolumn cryogenic distillation systems in

order to minimize HETP;- The FLOSHEET code has been further benchmarked;- Multiple columns can be stably controlled using inventory control;- Small columns should not be closely coupled to large columns, in order to improve the

stability of the smaller column.

Future experimental work should:- Complete characterization of 30-mm column, including measurement of HETP versus

inventory over a range of operating conditions;- Test OHT improved low-inventory packing (potentially 20% improvement);- Test the interaction between the upper (large diameter) and lower (small diameter) section of

a column with an intermediate reboiler, as an option for reducing the ITER tritium inventory.

Page 6: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

ITER TASK T48 (1994):LOW-INVENTORY CRYOGENIC DISTILLATION TESTS

2. TASK OBJECTIVES

The objective of this ITER task was to design and construct a column section for demonstrationof scale-up of low inventory cryogenic distillation.

The anticipated results are:1. Determine smallest column diameter that can handle full boilup of 60 W with Helipak;2. Measure D and T inventory in this column;3. Measure HETP for this column as a function of column inventory and column boilup;4. Combine these measurements with previous from small diameter columns to provide

reference estimates of HETP versus column diameter, and extrapolate the results to ITERreference conditions to indicate minimum expected ITER tritium inventory.

3. THEORY

Minimizing the tritium inventory in a cryogenic distillation system requires attention to severalfactors:- optimum combination of column diameter, packing and operating conditions to minimizeholdup per stage;- column operating conditions and configuration (position of equilibrators) to create tritiumconcentration profile that is pushed to the bottom of the final column;- reboiler design that has the minimum liquid inventory necessary for stable operation;- tapered cascade (multiple columns or tapered column).

Some of these parameters must be empirically determined, and then an optimized design (oroperating scheme) can be found with the assistance of computer codes such as FLOSHEET [1].

Previous work at Ontario Hydro Technologies (OHT) had shown that small cryogenic columns -as low as 4.6-mm diameter - could be stably controlled and designed to much lower inventoriesthan had been previously thought possible. Among the results were measurements of Height-of-Equivalent-Theoretical-Plate (HETP) versus holdup for Heli-Pak A and B in columns up to 20mm diameter and 30-35 W condenser duty. These results were used to design and build thePrinceton Tritium Purification System, with a predicted tritium inventory of < 1 g [2] ThePrinceton purity requirement is 99%, but there should be sufficient plates to produce 99.9% T.

ITER cryogenic distillation column designs suggest that the final high-tritium columns could have70-200 W condenser duty, with 30-70 mm diameter. Therefore, in order to extend our previousresults to ITER with confidence, tests on larger diameter columns were required.

Page 7: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

4. EXPERIMENT DESCRIPTION

The experiments are to be carried out in the Cryogenics Distillation Laboratory at OHT, in thefacility used for previous low-inventory column tests. The cold box was enlarged, and the largercolumn and cooling system assembled. The control system was upgraded. Existing mechanicalhelium refrigerators are used.

Figure 1 illustrates the experimental setup (note that feed and sample points areinterchangeable). The system has the following characteristics:- Approx 55 W condenser capacity;- 30-mm diameter column loaded with Helipak B;- approx. 1500 mm packed height.

The instrumentation is as follows:- 8 temperature diodes located on the cooling system, condenser, mid-column and reboiler;- 4 absolute pressure gauges;- 2 differential pressure gauges (packing liquid inventory and reboiler liquid level).

The control is provided by:- 4 flow controllers (flow into and out of the column, and in tritium sampling system);- 4 feed, withdrawal or sampling points along the column;- 486 computer with Labview software for data acquisition, analysis and control, with sampling

frequency of about 0.5 Hz.

The column will be fed with a D2/DT mixture at a feed rate up to 13 mol/hr. Under theseconditions, the reflux ratio will vary up to 17. The DT concentration will be restricted to tracelevels in the feed, but tritium will be injected at above background levels in order to reduce thetime required to setup the tritium profiles in the column.

The number of theoretical plates in the column will be determined as follows. A gas sample iswithdrawn from the column at the product end and oxidized to water. This water is trapped in ascintillation vial, weighed, scintillation cocktail added, and then the tritium is counted. Eachwater sample is collected for about 1.5 hours to ensure representative results. The producttritium level is thus determined to within 3%. Since the DT concentration in the column changesby about 20% per theoretical plate, accurate estimates for the number of plates are obtained bycomparing experimental results with FLOSHEET simulations.

Page 8: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

5. RESULTS

5.1 30-mm Column Design/Fabrication

The first task was to design and build the scaled-up test facility. Most of the changes werestraightforward. However, the refrigeration system design was more complex. In order toreduce costs, it was necessary to use existing 30-35 W helium refrigerators. Therefore, toprovide 60-W duty to the 30-mm column, two refrigerators had to be well-coupled thermally tothe column condenser. But since the refrigerator cold heads have very thin shells, it was notpossible to have them rigidly coupled to eachother (the thermal contraction down to cryogenictemperatures alone would be sufficient to destroy them). The solution was to attach the columnfirmly to one cold head, and indirectly to an adjacent cold head through flexible copper braid.Several iterations were required to obtain the desired good heat transfer with flexible mechanicalconnection.

The present design of thermal connection is based on several layers of high-conductivity copperbraid, interlaid with indium foil, and precompressed together tightly to form the connections atthe cold head and column condenser. Tests indicate that this system is able to provide 55 Wcondenser duty. This is sufficient for present tests, although we believe that some furtherimprovements are still possible.

General drawings of the frame and cold box, top flange, and column are provided in Figures 2-4.

5.2 30-mm Column Tests

In the range of column diameters expected for the ITER high-tritium col-umn, Heli-Pak B wouldbe our recommended low-inventory packing, based on our small-diameter column hydrogendata and on the manufacturer's published hydrocarbon data. Figure 5 summarizes thishydrocarbon data and our previous measurements with Heli-Pak B. Figure 5 also illustrates ourassumed values of HETP for FLOSHEET modelling purposes. Specifically, we use a H2 HETPof 2.5 cm for columns below about 25 mm diameter, and expect that the H2 HETP at 50-mmdiameter would have increased slightly to 2.5-3 cm. The present experiments will verify theseassumptions up to 30-mm diameter column. This corresponds to the expected smallestpractical diameter column for 60 W condenser duty.

The reference 30-mm column tests will be based on the following nominal conditions:- 900 torr pressure;- 5 L/min feed rate;- 55 W condenser power;- total reflux;- Heli-Pak B;- D2 feed with trace DT.

A FLOSHEET simulation of a possible experiment is attached (Figure 6). The simulation showsa 60-plate column fed 15 plates below the condenser. The column is operated with 5 L/minfeed, and 1 mL/min bottom drawoff, with 55 W condenser power. Note that the bottom DTconcentration is enriched by almost 4,000 while the top DT concentration is depleted by about afactor of 5, with most of the DT residing in the bottom of the column.

Page 9: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

Development of the control systems were carried out on a 4.6-mm column at OHT, inpreparation for the 30-mm column tests. Also in other commissioning tests, procedures forwetting the 4.6-mm column were tested. Figure 7 illustrates the effect of startup procedure onthe packing performance. In the initial set of experiments, the column was brought toequilibrium at its normal operating conditions. The tritium and total Q2 (liquid) inventory(measured by column pressure drop) are shown in Figure 7 in arbitrary units. In the second setof experiments, the Q2 inventory in the column was deliberately increased to completely wet thepacking. During this phase, the tritium product concentration increased - indicating that thecolumn was operating with more theoretical plates (or that the HETP had decreased). In thethird and fourth set of experiments, the Q2 inventory was reduced, but the tritium productconcentration continued to increase (i.e., HETP continued to drop). Lowering the Q2 inventoryback to the original operating conditions, the column continued to produce - in steady-state - atritium product concentration 1.6 times larger than before the packing treatment. Note thatlowering the Q2 inventory further finally starts to lower the product tritium concentration,presumably because the packing is starting to dry out. This process enables us to obtain themaximum number of theoretical plates from the column while minimizing the tritium inventory perplate. This (and other) processes were also applied successfully during commissioning thePrinceton TPS system in 1994, and wili be tested on the 30-mm ITER column at OHT.

5.3 Princeton TPS Four-Column System

During 1994, the Princeton Tritium Processing System (TPS) was installed and commissioned.The results from this experience are relevant to the ITER cryogenic distillation system, and arebriefly summarized here. Figures 8 and 9 are flow schematics for the Princeton systempermeator and cryogenic distillation systems.

The Princeton system uses a staged diffuser configuration to provide clean hydrogen feed to thecryogenic distillation system. This configuration is similar to that proposed for the ITER fuelcleanup system front-end. It has worked very well, with performance near its theoretical limit.For example, in commissioning tests with 120 NL/hr of 33% N2l 50% D2 and 17% H2 at 1400torr, the waste stream was essentially pure N2, with only 1400 ppm Q2.

For the reference commissioning case described above, the H2 product from Column 1contained < 0.1% HD, and the D2 product with Column 3 contained < 0.1% HD (the purity of theproduct could not be read to greater accuracy).

Commissioning was largely as expected, with some minor problems that have been solved. Forexample, thermal radiation onto the small capillary return line from CDS to CD1 has reduced itscapacity, but this will not limit the performance for Princeton conditions.

One important observation is that inventory control provides stable control of the system,including the fourth small (4.6-mm diameter) high-tritium column CD4. To optimize performanceand minimize tritium inventory, the Q2 inventory in each column must be controlled (the Q2 levelis measured from the pressure drop across the column). The Q2 inventory in CD1 is controlledby adjusting the sum of the draw-off rates for the H2 (top of CD1) and D2 (top of CDS) streams.The split between H2 and D2 drawoff is controlled so that a constant D2 concentration ismaintained in the center of CD1 (measured by the temperature and pressure in the center ofCD1). If the D2 level is too high, the D2 drawoff rate is increased and the H2 rate is decreased.Inventory control in columns 2,3 and 4 is simpler. If the column pressure drop signal is above

Page 10: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

the set point, indicating too much Q2 inventory, the condenser temperature is raised by thecontrol system. This increases the pressure in the column and increases the flow out of thecolumn. (In the Princeton TPS system, the feed-forward flows are pumped, but the feed-backward flows are controlled only by the pressure differecne between the two columns.) Figure10 shows an example of stable four-column control during commissioning tests at Princeton.

The final small column CD4 is now operating more smoothly than during the previouscommissioning tests at OHT. Part of this improvement is because it has been found better toprovide some degree of isolation between the small column and the other larger ones. This hasnot been an issue on Darlington-scale cryogenic distillation columns, but - at Princeton systemscale - pressure fluctuations in column CD2 were translated into much larger oscillations incolumn CD4. These prevented Column CD4 from running as close to its optimal point asdesired. The solution in the Princeton system was to reduce the diameter of the return line fromCD4 to CD2 to provide a pressure drop, which also meant that CD4 operated at a higherpressure than CD2 (approx 1100 torr rather than 900 torr).

Page 11: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

6. DISCUSSION

Relative to the task objectives (Section 2), we have carried out the following:1. Designed, built and commissioned a 30-mm cryogenic column test facility;2. Combined measurements from OHT and from PPPL TPS experience to provide

reference estimates of HETP versus column diameter for Helipak B;3. Applied these results, with FLOSHEET, to optimize the ITER design and reduce

the tritium inventory (from 180 g to 130 g, based on the Sept 1994 reference design).We have not yet measured the inventory and holdup versus HETP for the 30-mm ITER testcolumn. Commissioning tests for other cryogenic distillation columns has also provided relevantinformation on diffusers and on column design.

The implications of the 1994 results are:- Staged diffusers provide efficient, clean and low-inventory separation of hydrogen suitable for

cryogenic distillation feed;- Column wetting procedures can be applied to multicolumn cryogenic distillation systems in

order to minimize HETP;- The FLOSHEET code has been further benchmarked;- Multiple columns can be stably controlled using inventory control;- Small columns should not be closely coupled to large columns, in order to improve the

stability of the smaller column.

Future experimental work should:- Complete characterization of 30-mm column, including measurement of HETP versus

inventory over a range of operating conditions;- Test OHT improved low-inventory packing (potentially 20% improvement);- Test the interaction between the upper (large diameter) and lower (small diameter) section of

a column with an intermediate reboiler, as an option for reducing the ITER tritium inventory;- Further optimize the reference ITER cryogenic distillation system design based on this data.

The new OHT packing has been shown in scoping tests with water (for water distillationpurposes) to have a surprisingly low HETP, and therefore should be tested with hydrogen also.The test of a column with an intermediate reboiler is based on our observation, duringcommissioning of the Princeton TPS, that closely coupling a large and small column creates aless stable environment in the small column. A split column with intermediate reboiler should beequivalent to such a large-small column pair, and there have been no tests of split hydrogendistillation columns on an ITER-relevant scale. Appropriate tests of both the new packing and ofa split column can be carried out in the present OHT Low-Inventory Cryogenic Distillation testfacility.

7. REFERENCES

1. A. Busigin and S.K. Sood, "FLOSHEET - A computer program for simulating hydrogenisotope separation systems", Fusion Technology 14 (1988) 529.

2. A. Busigin, C. Busigin, F. Adamek, K. Woodall, J. Robins et al., "Control systemimplementation for a complex low-inventory cryogenic distillation system for PrincetonTFTR", Proc. 18th SOFT, Karlsruhe (1994).

Page 12: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

Figure 1. Schematic diagram of Low-inventory Cryogenic Distillation test facility at OntarioHydro Technologies.

Figure 2. Drawing of cold box and frame.

Figure 3. Drawing of the cold box flange.

Figure 4. Drawing of column.

Figure 5. Summary of HETP versus column diameter estimates for Heli-Pak B.

Figure 6. Example DT concentration profile in 30-mm column test (from FLOSHEET).

Figure 7. Effect of start-up procedure on tritium separation performance (results from 4.6-mmcolumn tests).

Figure 8. Flow schematic of PPPL IPS front-end staged diffuser system.

Figure 9. Flow schematic of PPPL TPS cryogenic distillation system.

Figure 10. Column pressure drop signals from PPPL commissioning tests showing stableoperation of four-column system.

Page 13: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

ITER DEMONSTRATION - LOW INVENTORY OD

Compressor

Compressor#2

0,/DTGas Mixture

3.35m

ColdBox

Coupler

Condenser60W

Rebeller60W

I ! [•••!

Column1.5m<f> 3 30 mnr

DT-^-DTO

IceBoth

Balance

0 0scintillation

•....counter

Control Panel:

approx. 40 valves4 Mass Flow Controllers4 Absolute Pressure Gauges2 Differential Pressure Gauges

Control Computer

Figure 1. Schematic diagram of Low-inventory Cryogenic Distillation test facility at OntarioHydro Technologies.

Page 14: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

//s//////////////////////////////////////'/////

FRONT VIEW

N3.

O-C-O3 COLD BOX OW6ER «I

OO-07 CCLD BOX »2

CH2-O8 COLD BOX Q-W-6S «3

CH2-09 CCLD BOX OW«ER M

CKZ-0 COLD BOX OW6S1 «5

CHj-02 TOP FLNCE

OOH BASE R_AN3£

OC-B COLD BOX SfPORT BRACKETS B)

SECTION •A-A-SECTION ~B-B"

ONTARIO HYDRO TECHNOLOGESflB? DEMONSTRATIONCOLD BOX ASSEMBLY

AU. DteSONS ARE N NOES

TOLBUNNCES UNLESS OTV6WBE SFKfiËD

DRN DAVD BELLAMY

CH2-06

JULY

SCALE H2

REVO

Figure 2. Drawing of cold box and frame.

Page 15: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

PAVE PASSTKRU l>€ATËa Wfl£S-2î AWG1t-SWAGaOK REDUCERS (SV20CHMI

ONTARIO HYDRO TECHNOLOGES

Figure 3. Drawing of the cold box flange.

Page 16: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

ITER DEMONSTRATION COLUMN

COLUMN PACKED LENGTH 150 M(HELIPAK "B")

ONTARIO HYDRO TEOMOLOGESrlBl ISOBTRATDI

UCMVOOOC *«OAVDBBJLOT

cec g -

L9I5 M

Figure 4. Drawing of column.

Page 17: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

o•s

CL

111

3

1

0

- • Trimethylpentane• H2 - measured

— H2 - model

10 20 30 40

Column Diameter, mm

50

Figure 5. Summary of HETP versus column diameter estimates for Heli-Pak B.

Page 18: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

OHT ITER TEST COLUMNFeed = 5 L/min. normal D2 With DT = 3E-14 mol frac.

Column = 30 rnm Dia., Packed Ht. = 1.5 m

1.20E-10

g 1.00E-10

o8.00E-11

6.00E-1 1

Q.4.00E-11CO

Q2.00E-11

7.00E-15 11 ±LiJ.Lll J r i i J Jilx'iJ: J li t J i i ( i i * ? I i 1 » i I

1 6 11 16 21 26 31 36 41 46 51 56

Number of Theoretical Plates

Figure 6. Example DT concentration profile in 30-mm column test (from FLOSHEET).

Page 19: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

AIIIZoH

Izoo

DÛO&CL,

S

DH

3.5

2.5

WOS

1.5

AFFECT OF START-UP PROCEDURES ON TRITIUM SEPARATION PERFORMANCERESULTS FROM PROTOTYPE PRINCETON HIGH T COLUMN

2.5

AIII

ZS

8z

1.5 o

Z|

OW

0.52 3 4

EXPERIMENT GROUP NUMBER >

Rel. Q2 Col. Inven. T Prod. Cone.

Figure 7. Effect of start-up procedure on tritium separation performance (results from 4.6-mmcolumn tests).

Page 20: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

FeedSI liters/Hr Hydrogen Isotopes40 Liters/Hr Nitrogen

+ other Impurities

1400torr

Bellows FeedPump

PalladiumDiffuserRSI50

50 torr

Waste 1400 ppm Q2

Pressure Control Valve

PalladiumDiffuserRSI 501 torr

High Vacuum Bellows BackingScroll Pump Pump

Feed tothe CD

Tritium Processing SystemPrinceton Plasma Physics LaboratoryFeed Treatment System

Figure 8. Flow schematic of PPPL IPS front-end staged diffuser system.

Page 21: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

FEEDHydrogen Isotopes81 Liters/Hr

H, STREAM<10'7% T20.2 Liters/Hr

GDI •*

CD2w EQ3 *fc-

C]

EQ2

Tritium Processing SystemPrinceton Plasma Physics LaboratoryDistillation Cascade

Ontario Hydi-oTechnologies

CD4

D3 STREAM<10-'% T60.25 Liters/Hr

T, PRODUCT93.9 % T0.163 Liters/Hr

Figure 9. Flow schematic of PPPL IPS cryogenic distillation system.

Page 22: ITER TASK T48 (1994) LOW-INVENTORY CRYOGENIC …

Pressure Drop, Torr

ça'ccBp

o o

5 3^ T3

w"-<; 3W QJ.CD »

t)tJt)

OO

3w'ÇAo"

CQ

wÇA^*O

5"çaco»-*.Q]çyCD