6
GT 1 Engine Number 191-614 T48 probe A B C D E F G H Date of installation 20/02/2011 Factory 20/02/2011 20/02/2011 20/02/2011 Factory 20/02/2011 20/02/2011 Serial Number FDTE6359 FDT61484 FDT040645/B77-01 DT90820 DT90823 FDT72652 FDTF0735 FDTE4452 Release of SB230 Revision 4 Date of inspection according SB230 19/2/2011 19/2/2011 19/2/2011 19/2/2011 19/2/2011 19/2/2011 19/2/2011 19/2/2011 Inspector (GE or AI) AI AI AI AI AI AI AI AI Inspection of Serial Numbers only while probe installed (yes or no) NO NO NO NO NO NO NO NO Inspection of removed probe (yes or no) YES YES YES YES YES YES YES YES Compliance date to GE 21/02/2011 21/02/2011 21/02/2011 21/02/2011 21/02/2011 21/02/2011 21/02/2011 21/02/2011 Findings according SB230 Inspector's Name Missing sleeve but no premature wear at tip Missing sleeve AND premature wear at tip Missing sleeve and tip liberation Upset egde not clearly visible in retaining hole No upset edge visible Slot rotated so that upset edge outside retaining hole Slot not visible Crack in upset edge T48 probe removal not possible Recommended for replacement (yes or no) Replacement Date of Replacement Serial Number of new installed probe By whom replaced (GE or AI) Supplier of probe (APM or GE) Inspector (GE or AI) Signature / Date Inspector ______________/_________________ Approver _________________/__________________ Jul 13,2009  Alghanim International General Trading & Contracting Co. W.L.L EPP - SABIYA T48 Thermocouples Inspection 70246675.xls.ms office 1/6 PRINT Date 4/21/2012

Upload: sathish-prabu

Post on 07-Apr-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: T48 Inspection Latest

8/4/2019 T48 Inspection Latest

http://slidepdf.com/reader/full/t48-inspection-latest 1/6

GT 1

Engine Number 191-614

T48 probe A B C D E F G HDate of installation 20/02/2011 Factory 20/02/2011 20/02/2011 20/02/2011 Factory 20/02/2011 20/02/2011

Serial Number FDTE6359 FDT61484 FDT040645/B77-01 DT90820 DT90823 FDT72652 FDTF0735 FDTE4452

Release of SB230 Revision 4

Date of inspection according SB230 19/2/2011 19/2/2011 19/2/2011 19/2/2011 19/2/2011 19/2/2011 19/2/2011 19/2/2011

Inspector

(GE or AI) AI AI AI AI AI AI AI AI

Inspection of Serial Numbers only while probe installed

(yes or no) NO NO NO NO NO NO NO NO

Inspection of removed probe(yes or no) YES YES YES YES YES YES YES YES

Compliance date to GE 21/02/2011 21/02/2011 21/02/2011 21/02/2011 21/02/2011 21/02/2011 21/02/2011 21/02/2011

Findings according SB230

Inspector's Name

Missing sleeve but no premature wear at tip

Missing sleeve AND premature wear at tip

Missing sleeve and tip liberation

Upset egde not clearly visible in retaining hole

No upset edge visible

Slot rotated so that upset edge outside retaining hole

Slot not visible

Crack in upset edge

T48 probe removal not possible

Recommended for replacement (yes or no)

Replacement

Date of Replacement

Serial Number of new installed probe

By whom replaced

(GE or AI)Supplier of probe

(APM or GE)Inspector

(GE or AI)

Signature / Date Inspector ______________/_________________ Approver _________________/__________________

Jul 13,2009

 Alghanim International General Trading & Contracting Co. W.L.LEPP - SABIYA

T48 Thermocouples Inspection

70246675.xls.ms_office 1/6 PRINT Date 4/21/2012

Page 2: T48 Inspection Latest

8/4/2019 T48 Inspection Latest

http://slidepdf.com/reader/full/t48-inspection-latest 2/6

Site

GT 2

Engine Number 191-615

T48 probe A B C D E F G H

Date of installation 6/10/2010 6/10/2010 3/2/2011 6/10/2010 3/2/2011 6/10/2010 6/10/2010 3/2/2011

Serial Number DT92450 DT92441 DT92442 DT92435 DT90825 DT92439 DT92444 DT92446

Release of SB230 Revision 4

Date of inspection according SB230 1/2/2011 5/8/2011 5/8/2011 5/8/2011 5/8/2011 5/8/2011 5/8/2011 1/2/2011

Inspector

(GE or AI) AI AI AI AI AI AI AI AI

Inspection of Serial Numbers only while probe installed

(yes or no) NO NO NO NO NO NO NO NO

Inspection of removed probe(yes or no) YES YES YES YES YES YES YES YES

Compliance date to GE 6/10/2010 6/10/2010 6/10/2010 6/10/2010 6/10/2010 6/10/2010 6/10/2010 6/10/2010

Findings according SB230

Inspector's Name Sibish K Philip

Missing sleeve but no premature wear at tip X X X

Missing sleeve AND premature wear at tip

Missing sleeve and tip liberation

Upset egde not clearly visible in retaining hole

No upset edge visible

Slot rotated so that upset edge outside retaining holeSlot not visible

Crack in upset edge

T48 probe removal not possible

Recommended for replacement (yes or no) No NO NO Yes Yes Yes

Replacement

Date of Replacement 5/8/2011 5/8/2011 5/8/2011

Serial Number of new installed probe DTF6675 DTF1091 FDT6675

By whom replaced

(GE or AI) AI AI AI

Supplier of probe

(APM or GE)Inspector

(GE or AI) AI AI AI

Signature / Date Inspector Sibish K Philip Approver _________________/__________________

Sabiya

Jul 13,2009

 Alghanim International General Trading & Contracting Co. W.L.L

EPP - SABIYA

T48 Thermocouples Inspection

70246675.xls.ms_office 2/6 PRINT Date 4/21/2012

Page 3: T48 Inspection Latest

8/4/2019 T48 Inspection Latest

http://slidepdf.com/reader/full/t48-inspection-latest 3/6

GT 3

Engine Number 191-603

T48 probe A B C D E F G H

Date of installation 2/2/2011 18/10/2010 20/03/2010 2/2/2011 Factory 2/2/2011 2/2/2011 2/9/2010

Serial Number FDTF5197 FDTA1306 FDTA1285 FDTF5194 FDT61513 FDTF1645 FDTE4801 DT92436

Release of SB230 Revision 4

Date of inspection according SB230 4/8/2011 4/8/2011 4/8/2011 4/8/2011 4/8/2011 4/8/2011 4/8/2011 4/8/2011

Inspector

(GE or AI) AI AI AI AI AI AI AI AI

Inspection of Serial Numbers only while probe installed

(yes or no) NO NO NO NO NO NO NO NO

Inspection of removed probe(yes or no) YES YES YES YES YES YES YES YES

Compliance date to GE 3/2/2011 3/2/2011 3/2/2011 3/2/2011 3/2/2011 3/2/2011 3/2/2011 3/2/2011

Findings according SB230

Inspector's Name Sibish K Philip

Missing sleeve but no premature wear at tip X X X

Missing sleeve AND premature wear at tip

Missing sleeve and tip liberation

Upset egde not clearly visible in retaining hole

No upset edge visible

Slot rotated so that upset edge outside retaining holeSlot not visible

Crack in upset edge

T48 probe removal not possible

Recommended for replacement (yes or no) Yes No No Yes Yes Yes No No

Replacement

Date of Replacement 4/8/2011 4/8/2011 4/8/2011 4/8/2011

Serial Number of new installed probe DTF6720 DTF6681 FDT37542 DTF5883

By whom replaced

(GE or AI) AI AI AI AISupplier of probe

(APM or GE)Inspector

(GE or AI) AI AI AI AI

Remarks: E sensor Replaced because of KN Lug thread damage

Signature / Date Inspector Sibish K Philip Approver _________________/__________________

Jul 13,2009

 Alghanim International General Trading & Contracting Co. W.L.LEPP - SABIYA

T48 Thermocouples Inspection

70246675.xls.ms_office 3/6 PRINT Date 4/21/2012

Page 4: T48 Inspection Latest

8/4/2019 T48 Inspection Latest

http://slidepdf.com/reader/full/t48-inspection-latest 4/6

GT 4

Engine Number 191-601

T48 probe A B C D E F G H

Date of installation 31/07/2011 31/07/2011 31/07/2011 31/07/2011 31/07/2011 31/07/2011 31/07/2011 31/07/2011

Serial Number FDT60010 FDT60012 FDT27444 FDT61511 FDTA6221 FDT60011 FDTF5003 FDT90752

Release of SB230 Revision 4

Date of inspection according SB230 31/07/2011 31/07/2011 31/07/2011 31/07/2011 31/07/2011 31/07/2011 31/07/2011 31/07/2011

Inspector

(GE or AI) AI AI AI AI AI AI AI AI

Inspection of Serial Numbers only while probe installed

(yes or no) NO NO NO NO NO NO NO NO

Inspection of removed probe

(yes or no) YES YES YES YES YES YES YES YES

Compliance date to GE 19/1/2011 19/1/2011 19/1/2011 19/1/2011 19/1/2011 19/1/2011 19/1/2011 19/1/2011

Findings according SB230

Inspector's Name Binu Joseph

Missing sleeve but no premature wear at tip X

Missing sleeve AND premature wear at tip

Missing sleeve and tip liberation

Upset egde not clearly visible in retaining hole

No upset edge visible

Slot rotated so that upset edge outside retaining hole

Slot not visible

Crack in upset edge

T48 probe removal not possible

Recommended for replacement (yes or no) No No No yes No No No No

Replacement

Date of Replacement 31/07/2011

Serial Number of new installed probe FDT60006

By whom replaced

(GE or AI) Al

Supplier of probe(APM or GE)

Inspector

(GE or AI)

Signature / Date Inspector Binu Joseph Approver _________________/__________________

Jul 13,2009

 Alghanim International General Trading & Contracting Co. W.L.L

EPP - SABIYA

T48 Thermocouples Inspection

70246675.xls.ms_office 4/6 PRINT Date 4/21/2012

Page 5: T48 Inspection Latest

8/4/2019 T48 Inspection Latest

http://slidepdf.com/reader/full/t48-inspection-latest 5/6

GT 5

Engine Number 191-593

T48 probe A B C D E F G H

Date of installation 21/03/2011 21/03/2011 21/03/2011 21/03/2011 21/03/2011 21/03/2011 21/03/2011 21/03/2011

Serial Number FDTE6992 FDTF5025 FDTF5026 FDTF5034 FDTF5035 FDTF5031 FDTF5036 FDTF5128

Release of SB230 Revision 4

Date of inspection according SB230 2/8/2011 2/8/2011 2/8/2011 2/8/2011 2/8/2011 2/8/2011 2/8/2011 2/8/2011

Inspector

(GE or AI) AI AI AI AI AI AI AI AI

Inspection of Serial Numbers only while probe installed

(yes or no) NO NO NO NO NO NO NO NOInspection of removed probe

(yes or no) YES YES YES YES YES YES YES YES

Compliance date to GE 21/3/2011 21/3/2011 21/3/2011 21/3/2011 21/3/2011 21/3/2011 21/3/2011 21/3/2011

Findings according SB230

Inspector's Name Sibish K Philip

Missing sleeve but no premature wear at tip X X X

Missing sleeve AND premature wear at tip

Missing sleeve and tip liberation

Upset egde not clearly visible in retaining hole

No upset edge visibleSlot rotated so that upset edge outside retaining hole

Slot not visible

Crack in upset edge

T48 probe removal not possible

Recommended for replacement (yes or no) Yes Yes No Yes No No No No

Replacement

Date of Replacement 2/8/2011 2/8/2011 2/8/2011

Serial Number of new installed probe DTF7083 FDTC8280 DT90819

By whom replaced

(GE or AI) AI AI AI

Supplier of probe

(APM or GE)Inspector

(GE or AI) AI AI AI

Signature / Date Inspector Sibish K Philip Approver _________________/__________________

Jul 13,2009

 Alghanim International General Trading & Contracting Co. W.L.L

EPP - SABIYA

T48 Thermocouples Inspection

70246675.xls.ms_office 5/6 PRINT Date 4/21/2012

Page 6: T48 Inspection Latest

8/4/2019 T48 Inspection Latest

http://slidepdf.com/reader/full/t48-inspection-latest 6/6

GT 6

Engine Number 191-672

T48 probe A B C D E F G H

Date of installation 2/2/2011 2/2/2011 2/2/2011 2/2/2011 2/2/2011 2/2/2011 2/2/2011 2/2/2011Serial Number FDTF5133 FDTE8936 FDTE8931 FDTE8939 FDTF5008 FDTF5192 FDTF1661 FDTF1664

Release of SB230 Revision 4

Date of inspection according SB230 3/8/2011 3/8/2011 3/8/2011 3/8/2011 3/8/2011 3/8/2011 3/8/2011 3/8/2011

Inspector

(GE or AI) AI AI AI AI AI AI AI AI

Inspection of Serial Numbers only while probe installed

(yes or no)

NO NO NO NO NO NO NO NO

Inspection of removed probe

(yes or no)YES YES YES YES YES YES YES YES

Compliance date to GE 2/2/2011 2/2/2011 2/2/2011 2/2/2011 2/2/2011 2/2/2011 2/2/2011 2/2/2011

Findings according SB230

Inspector's Name Sibish K Philip

Missing sleeve but no premature wear at tip X X

Missing sleeve AND premature wear at tip

Missing sleeve and tip liberation

Upset egde not clearly visible in retaining hole

No upset edge visibleSlot rotated so that upset edge outside retaining hole

Slot not visible

Crack in upset edge

T48 probe removal not possible

Recommended for replacement (yes or no) No No No No No Yes Yes No

Replacement

Date of Replacement 3/8/2011 3/8/2011

Serial Number of new installed probe FDTC8664 DTF7092

By whom replaced

(GE or AI) AI AI

Supplier of probe

(APM or GE)Inspector

(GE or AI) AI AI

Signature / Date Inspector Sibish K Philip Approver _________________/__________________

Jul 13,2009

 Alghanim International General Trading & Contracting Co. W.L.LEPP - SABIYA

T48 Thermocouples Inspection

70246675.xls.ms_office 6/6 PRINT Date 4/21/2012