iso 10005:1994

29
Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. इंटरनेट मानक !ान $ एक न’ भारत का +नम-णSatyanarayan Gangaram Pitroda “Invent a New India Using Knowledge” प0रा1 को छोड न’ 5 तरफJawaharlal Nehru “Step Out From the Old to the New” जान1 का अ+धकार, जी1 का अ+धकारMazdoor Kisan Shakti Sangathan “The Right to Information, The Right to Live” !ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता ह Bharthari—Nītiśatakam “Knowledge is such a treasure which cannot be stolen” IS 10005 (1994): SI Units and Recommendations for the Use of their Multiples and of Certain Other Units [MSD 10: Social Responsibility]

Upload: razvan-ionescu

Post on 04-Sep-2015

287 views

Category:

Documents


0 download

DESCRIPTION

STANDARD DIN FAMILIA ISO 9000

TRANSCRIPT

  • Disclosure to Promote the Right To Information

    Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public.

    ! $ ' +-Satyanarayan Gangaram Pitroda

    Invent a New India Using Knowledge

    01 ' 5 Jawaharlal Nehru

    Step Out From the Old to the New

    1 +, 1 +Mazdoor Kisan Shakti Sangathan

    The Right to Information, The Right to Live

    ! > 0 B BharthariNtiatakam

    Knowledge is such a treasure which cannot be stolen

    Invent a New India Using Knowledge

    IS 10005 (1994): SI Units and Recommendations for the Useof their Multiples and of Certain Other Units [MSD 10:Social Responsibility]

  • IS looo5: 1994 -I!50 looo: 1992

    Indian Sta~ndard SI UNITS AND RECOMMENDATIONS FOR THE USE OF THEIR MULTIPLES AND OF CERTAIN

    OTHER UNITS (Second Revision)

    UDC 006.057.5

    Q BIS 1994

    BU-REAU OF IN~DIAN STA~NDARDS MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG

    NEW DELHI 110002

    November 1994 Price Group 9

  • Basic Standards Sectional Committee, MSD 1

    NATIONAL FOREWORD

    This Indian Standard (Second Revision) which is identical with IS0 1000 : 1992 SI units and recommendations for the use of their multiples and of certain other units, issued by the International Organization for Standardization (ISO), was adopted by the Bureau of Indian Standards on the recommendation of the Basic Standards Sectional Committee (MSD 1) and approval of the Management and Systems Division Council.

    The text of the IS0 Standard has been approved as suitable for publication as Indian Standard without deviations. Certain conventions are, however, not identical to those used in Indian Standards. Attention is particularly drawn to the-following:

    a) Comma ( , ) has been used as a decimal marker while in Indian Standards the current practice is to use full point ( ) as the decimal marker.

    b) Wherever the words International Standard appear referring to this standard, they should be read as Indian Standard.

    This standard was first published in 1980 and then revised in 1985.

    In this second revision, the following changes have been made:

    a) Quantities and units from IS 1890 (Parts 9, 10, 12, and 13)/ISO 31 (Parts 9, 10, 12 and 13) have been added to Annex A (Normative) giving examples of decimal multiples and sub- multiples of SI units and of some other units which may be used. A cross reference to the item numbers of relevant standard has been made.

    b) The old definition of metre in Annex B has been replaced by new definition.

    c) The decision by International Committee for Weights and Measures (CIPM) in 1980 concerning the status of supplementary units has been incorporated.

    In the adopted standard, normative references appear to certain International Standards for which Indian Standards also exist. The corresponding Indian Standards which are to be substituted in their place are listed below along with their degree of equivalence for the editions indicated:

    In terna tional Standard

    IEC 27-l : 1971

    IS0 31-l : 1992

    IS0 31-2 : 1992

    IS0 31-3 : 1992

    IS0 31-4 : 1992

    IS0 31-5 : 1992

    Corresponding Indian Standard

    IS 3722 (Part 1) : 1983 Letter symbols and signs used in electric technology : Part 1 General guidance on symbols and subscripts (first revision)

    IS 1890 (Part 1) : 1994 Quantities and units: Part 1 Space and time (first revision)

    IS 1890 (Part 2) : 1994 Quantitiesand units: Part 2 Periodic and related phenomena (second revision)

    IS 1890 (Part 3) : 1994 Quantities and units: Part 3 Mechanics (second revision)

    IS 1890 (Part 4) : 1982) Quantities, units and symbols: Part 4 Heat (first revision)

    IS 1890 (Part 5) : 1994 Quantities and units: Part 5 Electricity and magnetism (first revision)

    Degree of Equivalence

    Technically equivalent

    Identical

    Identical

    Identical

    Technically equivalent

    Identical

    I) Under Revision

    (Continued on third cover)

  • IS 10005: 1994 IS0 1000:1992

    Indian Standard SI UNITS AND RECOMMENDATI.ONS FOR~THE USE OF THEIR IViJLTlPLES AND OF CERTAIN

    OTHER UNITS (Second Revision)

    1 Scope

    This International Standard

    a)

    b)

    describes the International System of Units) (in clauses 3, 4 and 6);

    recommends selected decimal multiples and sub- multiples of St units for general use and gives certain other units which may be used with the International System of Units (in clauses 5 and 7, and annex A);

    quotes the definitions of the SI base units (in an- nex B).

    Normative reference

    The following standard contains provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publica- tion, the edition indicated was valid. All standards are subject to revision, and parties to agreements based on this International Standard are encouraged to in- vestigate the possibility of applying the most recent edition of the standard indicated below. Members of

    IEC and IS0 maintain registers of currently valid International Standards.

    IEC 27-l :1971,2) Letter symbols to be used in elec- trical technology - Part 1: General

    3 SI units

    The name International System of Units (Systeme International dunites), with the international abbrevi- ation SI, was adopted by the 11 th General Conference on Weights and Measures (Conference G&kale des Poids et Mesures, CGPM) in 1960.

    This system includes:

    - base units

    - derived units including supplementary units

    which together form the coherent system of SI units.

    3.1 Base wits

    The International System of Units is based on the seven base units listed in table 1.

    1) Full InformatIon about the lnrernational System of Units IS given in a publication by the InternatIonal Bureau of Weights ana Measures (Bureau lnternationai des Poids et Mesures, BIPM): Le Sysr&ne lnremarional dlJnir6s (SO, irkluding an authorized English transiation.

    2) 5th edition. currently being revised.

    1

  • IS looo5: 1994 IS0 MOO : 1992

    Table 1 - SI base units

    SI base unit Base quantity

    Name Symbol

    length metre m

    mass kilogram kg

    time second S

    electric current ampere A

    thermodynamic kelvin K temperature

    amount of substance mole mol

    luminous intensity candela cd

    For the definitions of the base units, see annex 6.

    ~3.2 Derived units including supplementary units

    Derived units are expressed algebraically in terms of base units. Their symbols are obtained by means of the mathematical signs of multiplication and division; for example, the SI unit for velocity is metre per sec- ond (m/s).

    For some of the SI derived units, special names and symbols exist; those approved by the CGPM are listed in tables 2 and 3.

    The SI units radian and steradian are called supple- mentary units. They are dimensionless derived units (more precisely, derived units of dimension one) with special names and symbols. Although the co- herent unit for plane angle and for solid angle is ex- pressed by the number 1, it is convenient to use the special names radian (rad) and steradian (sr) respec-

    tively instead of the number 1 in many practical cases; for example the SI unit for angutar velocity can be written as radian per second (rad/s).

    It may sometimes be useful to express derived units in terms of other derived units having special names; for example, the SI unit for electric dipole moment is usually expressed as C - m instead of A. s - m.

    4 Multiples of SI units

    The prefixes given in table4 are used to form names and symbols of multiples (decimal multiples and sub- multiples) of the SI units.

    The symbol of a prefix is considered to be combined with the kernel symbol to which it is directly at- tached, forming with it a new symbol (for a decimal multiple or sub-multiple) which can be raised to a positive or negative power, and which can be com- bined with other unit symbols to form symbols for compound units.

    EXAMPLES

    = (JO-* m)3 = 10b6m3

    1 ps- z (lo-6s)- = 106s-

    1 mm*/s = (10m3 m)*/s = lo- m*/s

    Compound prefixes shall not be used; for example, write nm for nanometre, not mFm.

    NOTE 1 For historical reasons the name of the base unit for mass, the kilogram, contains the name of the SI prefix kilo. Names of the decimal multiples and sub-multiples Df the unit of mass are formed by adding the prefixes to the word gram, e.g. milligram (mg) instead of microkilogram

    Mg).

    3) In this case, the term kernel symbol means only a symbol for a base unit or a derived unit with a special name. See, however, note 1 in clause 4 about the base unit the kilogram.

    2

  • IS 10005 : 1994 IS0 1000: 1992

    Table 2 - SI derived units with special names, including SI supplementary units

    SI derived unit Derived quantity

    Spatial name Symbol Expressed in terms of SI base units and St derived units

    plane angle

    solid angle

    frequency

    force

    pressure, stress

    radian rad

    steradian sr

    hertz Hz

    newton N

    Pascal Pa

    1 rad = 1 m/m = 1

    1 sr=l m2/m2=1

    1 Hz = 1 s-l

    1 N = 1 kg - m/s2

    1 Pa = 1 N/m2

    energy. joule J 1 J=l N-m work, quantity of heat

    power, watt W 1 W = 1 J/s radiant flux

    electric charge, coulomb C 1 C=l A-s quantity of electricity

    eiectric potential, volt V 1 V=l W/A potential difference, tension, electromotive force

    capacitance farad F 1 F=l C/V

    electric resistance ohm a 1 Q = 1 V/A

    electric conductance siemens S 1 s = 1 a-

    magnetic flux weber Wb 1 Wb=l V.s

    magnetic flux density tesla T 1 T=l Wb/m2

    inductance henry H 1 H = 1 Wb/A

    Celsius temperature degree Celsiusl) C 1 CF~ K

    luminous flux lumen Im 1 Im = 1 cd a sr

    illuminance lux IX 1 lx = 1 lm/m2

    1) Degree Celsius is a special name for the unit kelvin for use in stating values of Celsius temperature. (See also note6 concerning the kelvin in annex B.)

    3

  • IS 19905 : 1994 IS0 1000: 1992

    Table 3 - SI derived units with special names admitted for reasons of safeguarding human health I

    .Derived quantity

    SI derived unit

    Special name Symbol Expressed in tarms of SI base units

    and SI derived units

    activity (of a radionuclide)

    absorbed dose, specific energy imparted, kerma, absorbed dose index

    becquerel

    gray

    Bq

    GY

    1 Bq = 1 s-

    1 Gy = 1 J/kg

    dose equivalent, dose equivalent index

    sievert sv 1 Sv = 1 J/kg

    Table 4 - Sl prefixes

    PWfiX Factor

    Name Symbol

    yotta Y zetta 2

    1018 exa E 1o15 peta P

    lOI2 tera T

    log giga G lo6 mega M

    lo3 kilo k

    lo2 hecto h 10 deca da 10-l deci d lo-* centi. C

    1o-3 milli m 1o-6 micro

    Or:*

    CI nano n

    10 pica P

    lo-l5 femto f 1 o-l8 atto a lo-* zepto 2 1o-24 yocto Y

    5 Use of SI units and their multiples

    5.1 The choice of the appropriate multiple (decimal multiple or sub-multiple) of an SI unit is governed by convenience, the multiple chosen for a particular- ap- plication being the one which will lead to numerical values within a practical range.

    5.2 The multiple can usually be chosen so that the numerical values will be between 0,l and 1 000. In the case of a compound unit containing a unit to the second or third power, this is not always possible.

    EXAMPLES

    I,2 x lo4 N can be written as 12 kN

    0,003 94 m can be written as 3,94 mm

    1 401 Pa can be written as 1,401 kPa

    3,l x 10-8s can be written as 31 ns

    However, in a table of values of the same quantity or in a discussion of such values within a given context, it will generally be better to use the same multiple for all items, even if some of the numerical values will then be outside the range 0,l to 1 000. For certain quantities in particular applications, the same multiple is customarily used; for example, the millimetre is used for dimensions in most mechanical engineering drawings.

    5.3 The number ~of prefixes used in formrng com- pound units should be limited as far as is compatible with practical usage.

    5.4 Errors in calculations can be avoided more easrly if all quantities are expressed in SI units, powers of 10 being used instead of prefixes.

    6 Rules for writing unit symbols

    6.1 Unit symbols shall be printed in roman (upright) type (irrespective of the type used in the rest of the text), shall remain unaltered in the plural, shail be written without a final full stop (period) except for normal punctuation, e.g. at the end of a sentence, and shall be placed after the complete numerical value in

    4

  • IS 10005 : 1994 IS0 1uw: 1992

    the expression for a quantity, leaving a space be- 7 tween the numerical value and the unit symbol,

    Non-S1 units which may be used with SI units and their multiples

    Unit symbols shall in general be written in lower case letters except that the first letter is written in upper case when the name .of the unit is derived from a proper name.

    7.1 There are certain units, outside the SI, recog- nized by the CIPM as having to be retained because of their practical importance (see tables 5 and 6).

    EXAMPLES

    m metre

    S second

    A ampere

    Wb weber

    7.2 Prefixes given in table4 may be attached to some of the units given in tables 5 and 6; for example, millilitre, ml. (See also annex A, column 6.)

    7.3 In a limited number of cases, compound units are formed with the units given in tables 5 and 6 to- gether with SI units and their multiples; for example, kg/h; km/h. (See also annex A, columns 5 and 6.)

    6.2 When a compound unit is formed by multipli- cation of two or more units, this should be indicated in one of the following ways:

    N-m, Nm

    NOT5 ,

    2 In systems with limited character sets a dot on the line is used instead of a half-high dot.

    3 The latter form may also be written without a space, provided that special care is taken when the symbol for one of the units is the same as the symbol for a prefix, e.g. mN is used only for millinewton, not for metre newton.

    When a compound unit is formed by dividing one unit by another, this should be indicated in one of the fol- lowing ways:

    m S m/s, m - s-l.

    A solidus (/) shall not be followed by a multiplication sign or a division sign on the same line unless parentheses are inserted to avoid any ambiguity. In complicated cases negative powers or parentheses shall be used.

    NOTE 4 There are some other units outside the SI which are recognized by the CIPM for temporary use. They are given in column 7 of the table in annex A and marked by an asterisk (*).

    Table 5 - Units used with the SI

    Unit Quantity

    Name Symbol Definition

    :ime minute min 1 min = 60 s

    hour h 1 h = 60 min

    day d 1 d=24h

    olane angle degree I0 = (x/l 80) rad

    minute I = (l/60)

    second 1 = (l/60)

    volume litre I, L) 1 I=1 dm3

    mass tonnes) t 1 t=103kg

    1) The two symbols for the litre are on an equal footing. The CIPM will, however, make a survey on the development of the use of the two symbols in order to see if one of the two may be sup- pressed.

    2) Also called the metric ton in the English lan- guage.

    -

    5

  • IS 10005: 1994 IS0 1000 : 1992

    Table 6 - Units used with the SI, whose values in SI units are obtained experimentally

    Quantity

    energy

    mass

    Name

    electronvolt

    unified atomic mass unit

    Unit

    Symbol Definition

    eV The electronvolt is the kinetic energy acquired by an electron in passing through a potential difference of 1 volt in vacuum: 1 eV 2: 1,602 177 x lo-J.

    U The unified atomic mass unit is equal to l/12 of the mass of an atom of the nuclide *C:

    I 1 u z 1,660 540 x lo-* kg.

    6

  • IS 10005: 1994 IS0 1000 : 1992

    Annex A

    Examples of -decimal multiples and sub-multiples of SI units and of some

    (normative)

    other units which may be used

    For a number of commonly used quantities, examples of decimal multiples and sub-multiples of SI units, as well as of some other units which may be used, are given in this annex. It is suggested that the selection shown, while not intended to be restrictive, will none the less prove helpful in presenting values of quantities in an identical manner in similar contexts within the various sectors of technology. For some needs (for example, in applications in science and education), it is recognized that greater freedom will be required in the choice of decimal multiples and sub-multiples of SI units than is exemplified in the list which follows.

    Item No. In IS0 31:

    1992

    Units outsido the SI recognized Selection by the ClPM as having to be

    of retained, and for spocisl cases multiples some of their combina-tlons with

    Quantity SI unit and sub- SI units Remarks and information about

    multiples of the SI

    Multiples or units used in special fields

    unit Units sub-multiples of

    units -given in column 5

    1 2 3 4 5 5 7

    Part 1: Space and time

    - 1-l angle, b rad (plane angle) (radian)

    gon [gon (;r grade)], 1 gon=---

    200 rad

    0 If the radian is not used, the cnits (degree) degree or gon (or grade) may be 1 -cad used. Decimal subdivisions of

    180 mrad

    degrea are preferable to minute , and second for most applications.

    (minute) For the units degree, minute and

    lL-& second for plane angle, there shall be no space between the

    I, numerical value and the unit

    (secon:~ symbol.

    1 e- 60

    prad

    1-2 solid angle Eteradian)

    l-3.1 length km 1 nautical mile* = 1 852 m

    Retre) (exactly)

    cm mm

    * pm

    Recognized by the CIPM for

    nm temporary use.

    K

    7

  • IS loo05 : 1994 IS0 1000: 1992

    Units outside the SI recognized

    Selection by the CIPM es having to be

    of retained, and for special cases

    ltom No. multiples some of their combinations with

    in IS0 31: Quantity SI unit end eub- SI units Remarks and information about

    1992 multlples Multlples or units used in special fields

    ofthrSI unit Units

    sub-multiples of units given in

    column 5 -

    1 2 3 4 6 6 7

    I-4 area km2 m2

    ha* (hectare), 1 ha = lo4 m2

    dm2 a* (are), 1 a = lo2 m2

    cm2 mm2

    l Recognized by the CIPM for temporary use.

    t-5 volume m3 In 1964, the CGPM declared that hi 1 hl = IO- m3

    the name litre (I) may be used as

    dm3 a special name for the cubic

    I, L decimetre (dm3) and advised (litre) against the use of the name litre 1 I= 10V3m3=

    for high-precision measure- ments.

    1 dm3 cl 1 cl E 10T5 m3

    See also footnote 1) to table 5.

    cm3 ml 1 ml = 10m6 m3 = 1 cm3

    mm3

    l-7 time

    Gecond)

    ks

    ms c1s ns

    d (day) 1 d=24h (exactly) h (hour) 1 h = 60 min (exactly)

    min (minute) 1 min = 60 s (exactly)

    Other units such as week, month and year (a) are in common use. The definitions of month and year often need to be specified.

    l-8 angular velocity

    rad/s

    I-10 velocity m/s km/h 1 km/h =

    l-11.1 accteleration m/s2

    mm/h & m/s

    1 knot* = 1,852 km/h (exactly) = 0,514 444 m/s

    For the hour, see item No. 1-7.

    l Recognized by the CIPM for temporary use.

    8

  • IS 10905: 1994 IS0 1000: 1992

    Item No. in IS0 31:

    1992 Quantity SI unit

    Units outside the SI recognized

    Selection by the CIPM as having to be

    of retained, and for special cases

    multiples some of their combinations with

    and sub- SI units Remarks and information about

    multiples Multiples or units used-in special fields

    of the SI unit Units

    sub-multiples of units given in

    column 5

    1 2 3 4

    Part 2: Periodic and related phenomena

    2-3.1 frequency THz GHz MHz kHz

    HZ (hertz)

    2-3.2 rotational S -1

    frequency

    2-4 angular rad/s frequency

    5

    min-

    6 7

    The designations revolutions per minute (r/min) and revo- lutions per second (r/s) are widely used for rotational fre- quency in specifications on rotat- ing machinery. (See also IEC 27-l .) For the minute, see item l-7.

    Part 3: Mechanics

    3-1

    3-2

    3-5

    3-7

    mass Mg t See footnote 2) to table 5. (tonne) 1 t=103kg

    kg (kilogram)

    g mg Pg

    volumic Mg/m3 or kg/dm3

    t/m3 or kg/l g/ml For the litre, see item No. l-6. mass,

    density,

    kg/m3

    or g/cm3 For the tonne, see item No. 3-1.

    mass density g/f

    lineic mass, kg/m 1 tex = IO- kg/m = 1 g/km linear density mglm

    The unit tex is used for textile filaments.

    moment of kg-m inertia

    3-8

    38.1

    momentum

    force

    - kg - m/s

    MN kN

    N (newton)

    mN

    PN

    9

  • IS iow5 : 1994

    Is0 1000: 1992

    Units outside the Si recognized

    Selection by the CIPM as heving to be

    of retained, and for special cases

    Item No. multiples some of their combinations with

    in IS0 31: Quantity SI unit and sub- SI units Remarks and information about

    1992 multiples Multiples or units used in special fields

    of the SI unit Units

    sub-multiples of unlts given in

    column 5

    -1 2 3 4 5 6 7

    3-l 1 moment of kg - m*/s momentum,

    angular momentum

    3-12.1

    3-15.1

    3-15.2

    moment of MN.m force kN . m

    N.m mN-m PN B m

    pressure GPa bar* (bar), 1 bar = 100 kPa MPa (exactly) kPa hPa 1 mbar = 1 hPa

    Pa (Pascal)

    The use of the bar shall be re-

    mPa stricted to existing uses in the

    PPa field of fluid pressure.

    l Recognized by the CIPM for temporary use.

    normal stress GPa MPa kPa

    Pa

    3-23 viscosity, (dynamic

    viscosity)

    Pa . s mPa.s

    P (poise) 1 cP= 1 mPa.s

    The poise and stokes are special names for CGS units. They and their multiples and sub-multiples shall not be used together with SI units.

    3-24 kinematic viscosity

    m2/s mm*/s

    St (stokes) 1 cSt = 1 mm*/s

    See remark on item 3-23.

    3-25 surface N/m tension mN/m

    3-26.1 and 3-26.2

    energy. work

    EJ PJ TJ GJ MJ kJ

    J (joule)

    mJ

    lb

  • IS looo!5: 1994 IS0 1990 : 1992

    ltom No. n IS0 21: Quantity

    1992

    1 2

    l-27 power

    art 4~ Heat

    Units outsido the SI recognized hction by the CIPM as having to be

    of rotalnod, and for special cases multiples some of their combinations with

    Si unit and sub- SI units Romrrks and information about multiples Multiploa or

    units uwd in specirl fields OfthoSl

    unit Unit8 rub-multiplesof units *on in

    column 6 3 4 S 6 7

    GW MW kW

    W (watt)

    mW PW

    l-1 thermo- K dynamic (kelvin) temperature

    I-2 Celsius C temperature (degree

    Celsius)

    The Celsius temperature-r is equal to the difference (T - TO) between two thermodynamic

    I temperatures T and To, where To =-273.15 K (exactly).

    I l-3.1 linear

    expansion coefficient

    K-l

    For the definition and the use of the degree Celsius (C), see note6 under the definition of the kelvin in annex B.

    For the degree Celsius, see item 4-2.

    66

    67

    heat EJ PJ TJ GJ MJ kJ

    J mJ

    heat flow rate kW W

    4-9

    618.1

    4-11

    Cl6

    thermal W/(m 8 Kl For the degree Celsius, see item conductivity 4-2.

    coefficient W/(m2 - K) For the degree Celsius, see item of heat 4-2. transfer

    thermal m2. K/W For the degree Celsius, see item insulance 4-2.

    heat capacity kJ/K For the degree Celsius, see item J/K 4-2.

    11

  • IS 10005 : 1994 IS0 1000: 1992

    item No. n IS0 31:

    1992 Ouantity Si unit

    Units outside the Si recognized

    Selection by the CiPM as having to be

    of retained, and for special cases

    multiples some of their combinations with

    and sub- St units Remarks and information about

    multiples Muitipies or units used in special fields

    of the Si unit Units

    rub-multiples of units given in

    column 5

    1 2 3 4 5 6 7

    I-16.1 massic heat kJ/(kg - K) For the degree Celsius, see item capacity J/M - K) 4-2.

    I-16

    619

    entropy

    massic entropy

    J/K

    J/M - K)

    kJ/K

    kJ/(kg . K)

    For the degree Celsius, see item 4-2.

    For the degree Celsius, see item 4-2.

    1-21.2 massic thermo- dynamic energy

    J/kg

    art 5: Electricity and magnetism

    i-l electric current

    kA A (ampere)

    mA PA nA PA

    5-2

    5-3 k

    6-4

    electric charge,

    quantity of electricity

    volumic charge,

    volume density of charge,

    charge density

    areic charge, surface density of charge

    A-h For the hour, see item No. l-7. 1 A-h- 3,6 kC

    kC C (coulomb)

    ClC nC PC

    C/mm3 or GC/m3

    MC/m3 or C/cm3

    kc/m3 C/m3

    mC/m3 PC/m3

    MC/m or C/mm

    C/cm2

    C/m2 kc/m2

    mC/m2 PC/m

    12

  • IS 10005:1994 IS0 1000:1992

    Units outside the SI recognized

    Selection by the CIPM as having to be

    of retained, and for special cases

    item No. multiples some of their combinations with

    in IS0 31: Quantity SI unit and sub- SI units Remerks and information ebout

    1992 multiples of the SI

    Multiples or units-used in special fields

    unit Units sub-multiples of

    units given in column 5

    1 2 3 4 5 6 7

    5-5 electric field MV/m strength kV/m or

    V/mm V/cm

    V/m mV/m Hm

    5-6.1 electric MV potential kV

    V 5-6.2 potential (volt)

    difference, mV tension IJJ

    5-6.3 electromotive force

    5-7

    5-8

    5-9

    5-10.1

    5-13

    5-14

    electric flux density

    C/m*

    electric flux

    C

    capacitance F (farad)

    permittivity F/m

    electric polarization

    C/m2

    electric dipole C - m moment

    C/cm* kc/m*

    mC/m* G/m*

    MC kC

    mC

    mF PF nF PF

    pF/m nF/m pF/m

    C/cm* kc/m*

    mC/m* G/m*

    .

    .

    i

  • IS 10005:1994 IS0 1000:1992

    Item No. in IS0 31:

    1992 Quentity

    Units outsidr the SI recognized

    Selection by the CIPM as heving to be

    of retained, and for special cases

    multiples some of their combinations with

    SI unit andsub- SI units Remarks and~lnformetion about

    multiples Multiples or units used in special fields

    ofthesl unit Units

    sub-multiples of units given in

    column 5

    1

    5-15

    2 3 4 5 6 7

    areic electric MA/m2 or current, A/mm2

    electric A/cm2 current

    A/m2 kA/m2

    density

    5-16 lineic electric kA/m or current, A/mm

    linear electric A/cm current A/m density

    5-17 magnetic field strength

    A/m

    kA/m or A/mm

    A/cm

    5-18.1 magnetic potential difference

    A kA

    mA

    5-19 magnetic flux T density, (tesla)

    magnetic induction

    mT PT nT

    5-20 magnetic flux Wb (weber)

    mWb

    5-21

    522.1

    5-22.2

    5-24

    5-27

    magnetic vector potential

    self- inductance

    mutual inductance

    permeability

    magnetic moment,

    electro- magnetic moment

    Wb/m

    H (henn/)

    H/m

    A-m

    kWb/m

    gblmm

    mH VH nH PH

    PHjm nH/m

    14

  • IS 10005: 1994 IS0 1000 : 1992

    Units outside the SI recognized

    Selection by the ClPM as having to be

    of retainad, and for special cases

    Item No. multiples some of their combinations with

    n IS0 31: Quantity SI unit and sub- SI units Remarks and information about

    1992 multiples Multiples or units used in special fields

    of the SI unit Units

    sub-multiples of unlts given in

    column 5

    1 2 3 4 5 5 7

    i-20 magnetization kA/m or A/mm

    A/m

    i-29 magnetic T polarization mT

    IEC magnetic N - m*/A !7-1:1971, dipole tern 88) moment &b-m

    i-33 resistance (to GCI direct MCI current) kn

    Ehm) mTL w

    i-34 conductance kS (of direct S current) (siemens)

    mS PS

    j-38 resistivity Gf2.m n-mm* Mn.m

    ii-_.(= lo-n.m =pn.rr

    kf2.m is also used. a-m

    R-cm ma-m paam Warn

    5-37 conductivity MS/m kS/m

    S/m

    5-38 reluctance H--l

    5-39 permeance H

    5-44.1 impedance, MQ (complex kn

    impedance) SL mn

    5-44.2 modulus of impedance,

    (impedance)

    544.3

    5-44.4

    resistance

    reactance

    15

  • IS 10005:1994 IS0 -1000:1992

    Item No. n IS0 31:

    1992 Quantity SI unit

    Units outside the SI recognized

    Selaction by the CIPM as having to ba

    of ratainrd, and for spatial cases

    multiples some of their combinations with

    and sub- SI units Remarks and information about

    multiplas Multiples or units used in special fields

    of-the SI unit Units

    sub-multiples of units given in

    column 5

    1 2 3 4 5 5 7

    -45.1 admittance, kS (complex S

    admittance) mS

    ClS i-45.2 modulus of

    admittance, (admittance)

    i-45.3

    i-45.4

    i-49

    conductance

    susceptance

    active power TW In electric power technology, ac- GW tive power is expressed in watts MW (W), apparent power in volt am- kW Peres (V - A) and reactive power

    W in vars (var). mW

    CIW nW

    i-52 active energy TW.h For the hour, see item l-7. GW-h

    TJ MW-h

    GJ kW.h

    MJ W-h 1 W.h= 3,6 kJ (exactly)

    kJ J

    #art 6: Light and related electromagnetic radiations

    i-3 wavelength m

    pm nm

    pm

    6-7 radiant J energy

    A* (angstrom), I A = IO-~ m = IO- nm = 10e4 pm

    l Recognized by the CIPM for temporary use.

    6-10 radiant W power,

    radiant , energy flux

    6-13 radiant intensity

    W/sr

    16

  • IS 10005:1994 IS0 1000:1992

    Units outside the Si recognized

    Selection by the CiPM es heving to be

    of retained, and for special cases

    item No. multiples some of their combinatfons with

    n IS0 31: Quantity Si unit and sub- SI units Remarks and information about

    1992 multiples of the SI

    Multiples or units used in special fields

    unit Units sub-multiples of

    units given in column 5

    1 2 3 4 5 6 7

    b14 radiance W/(sr - m*)

    i-15 radiant W/m* exitance

    i-16

    i-29

    i-30

    S-31

    6-32

    6-33

    irradiance W/m*

    luminous cd intensity (candela)

    luminous flux Im (lumen)

    quantity of light

    Im - s

    luminance cd/m*

    luminous lm/m* exitance

    Im - h 1 Im-h= 3 600 Im . s (exactly)

    For the hour, see item 1-7.

    6-34

    6-35

    illuminance

    light exposure

    lx

    (lux)

    lx * s

    636.1 luminous efficacy

    lm/W

    Part 7: Acoustics

    7-l period, s periodic time ms

    Ps

    7-2 frequency MHz kHz

    HZ

    7-5 wavelength m mm

    7-6 volumic kg/m3 mass,

    mass density, density

  • IS 10005 : 1994 IS0 1000 : 1992

    Units outside the Slrecognizrd

    Selection by the CIPM as having to~be

    of retained, end for special cases

    Hem No. multiples some of their combinations with

    n IS0 31: Quantity SI unit end rub- SI units Remarks and Information about

    1992 multiples of the SI

    Multiples or units used In special fields

    unit Units sub-multiples of

    units given in column 5

    1 2 -3 4 5 6 7

    -9.1 static Pa pressure mPa

    PPa r-9.2 (instantaneous)

    sound pressure

    r-11 (i;;;;Tneous) m/s

    particle velocity

    mm/s

    r-13 (instantaneous) m3/.s volume flow rate

    r-14.1 velocity of sound

    mls

    1-16

    r-17

    7-18

    sound power kW W

    mW

    FW PW

    sound W/m* intensity mW/m*

    pW/m* pW/m*

    acoustic Pa m s/m3 impedance

    .

    mechanical impedance

    surface _ density of mechanical impedance

    N - s/m

    Pa - s/m

    dB.(decibel), 1 dB = 10-l B

  • IS 10005 : 1994 IS0 1000 : 1992

    Units outside the SI recognized

    Selection by the CIPM as having to be

    of retained, and for special cases

    item No. multiples some of their combinations with

    in IS0 31: Quantity SI unit and sub- SI units Remarks and information about

    1992 multiples Multiples or units used in special fields

    of the SI unit Units

    sub-multiples of units given in

    column 5

    1 2 3 4 5 Q 7

    7-28 sound B reduction dB index

    7-29 equivalent absorption area of a surface or object

    m2

    7-30 reverberation s time

    Pati 8: Physical chemistry and molecular physics

    8-7 molar thermo- dynamic energy

    J/mol kJ/mol

    8-8

    8-9

    813

    molar heat J/(mol - K) For the degree Celsius, see item capacity 4-2.

    molar entropy J/(mol - K) For the degree Celsius, see item 4-2.

    concentration mol/dm3 mol/l For the litre, see item l-8. of 8, or

    amount-of- kmol/m3 substance mol/m3 concentration of B

    8-18

    8-39

    molality of solute B

    diffusion coefficient

    mol/kg

    m*/s

    mmol/kg

    19

  • IS 10005 : 1994 IS0 1000 : 1992

    tern No. 1 IS0 31:

    1992 Quantity SI unit

    Units outside the SI recognized

    Selection by the CPM as having to be

    of retained, and for special cases

    multiples some of their combinations with

    and sub- SI units Remarks and information about

    multiples Multiples or units used in special fields

    of the SI unit Unlts

    sub-multiples of units given in

    column 5

    1 2 3 4 5 0 7

    -41 thermal m2/s diffusion coefficient

    art 9: Atomic and nuclear physics

    I-28.2 mass defect kg

    tnified atomic mass unit),

    1 uz 1,660 540 x IO- kg

    1-33 activity

    Bq

    MBq kBq

    Ci+ (curie), 1 Ci = 3.7 x IO Bq (exactly)

    l Recognized by the CIPM for temporary use.

    b-34 massic activity,

    specific activity

    Bqlkg

    MBq/kg kBq/kg

    j-37 half-life

    S

    ms

    d h

    a (year) For the hour and the day, see item 1-7.

    art 10: Nuclear reactions and ionizing radiations

    so-1 reaction energy

    J GeV WleV keV

    eV (electronvolt), 1 eVk: 1,602 177 x lo-J

    10-51.2

    lo-52

    absorbed dose

    dose equivalent

    GY

    sv

    mGy

    mSv

    rad* (rad), 1 rad = lo- Gy

    * Recognized by the CIPM for temporary use.

    rem* (rem), 1 rem = lo- Sv

    l Recognized by the CIPM for temporary use.

    20

  • IS 10009: 1994 IS0 1000 : 1992,

    ltem No. in IS0 31:

    1992 Quantity SI unit

    Units outside the SI recognized

    Selection by the CIPM as having to be

    of retained, and for special cases

    multiples some of their combinations wlth

    and sub- SI unlta Remarks and information about

    multiples Multiples or units used in special fields

    of the SI unit Units

    sub-multiples of unlts.given In

    column 5

    1 2 3

    IO-58 exposure C/kg

    Part 12: Characteristic numbers

    12-1 Reynolds I number

    12-8 Mach number 1 /

    Part 13: Solid state physics

    13-17 density of states J-/m3

    13-20 Hall m3iC coefficient

    4 5 6 7

    R (rontgen),

    mC/kg 1 R = 2,58 x 1 0p4 C/kg (exactly)

    * Recognized by the CIPM for temporary use.

    As prefixes cannot be used, powers of 10 may be used, e.g. Re= 1,32 x lo3

    eVi/m3 For the electronvolt, see item 1 O-l.

    -

    13-21 thermo- V electromotive mV force

    13-24

    13-28.2

    13-38.1

    Thomson V/K coefficient

    gap energy J

    Curie K temperature

    mV/K

    fJ aJ

    eV

    For the degree Celsius, see item 4-2.

    For the electronvolt, see item 1 O-l.

    For the degree Celsius; see item 4-2.

    I

    21

  • IS lwo!5: 1994 IS0 1000.: 1992

    Annex B (informative)

    Definitions of the base units of the international system of units

    metre: The metre is the length of the path travelled by light in vacuum during a time interval of l/299 792 458 of a second.

    [17th CGPM (1983), Resolution I]

    kilogram: The kilogram is the unit of mass; it is equal to the mass of the international prototype of the kilogram.

    [3rd CGPM (1901)]

    second: The second is the duration of 9 192 631 770 periods-of the radiation corresponding to the transition be- tween the two hyperfine levels of the ground state of the caesium-133 atom.

    [13th CGPM (1967), Resolution l]

    ampere: The ampere is that constant current which, if maintained in two straight parallel conductors of infinite length, of negligible circular cross-section, and placed 1 metre apart in vacuum, would produce between these conductors a force equal to 2 x Leo_ newton per metre of length.

    [CIPM (1946), Resolution 2 approved by the 9th CGPM (1948)]

    kelvin: The kelvin, unit of thermodynamic temperature, is the fraction l/273,16 of the thermodynamic temperature of the triple point of water.

    [13th CGPM (1967), Resolution 4)

    NOTES

    5 The 13th CGPM (1967, Resolution 3) also decided that the unit kelvin and its symbol K should be used to express an interval or a difference of temperature.

    6 In addition to the thermodynamic temperature (symbol T), expressed in kelvins, use is also made of Celsius temperature (symbol r) defined by the equation t-T-To, where TO = 273,15 K by definition. To express Celsius temperature, the unit degree Celsius, which is equal to the unit kelvin, is used; in this case, degree Celsius is a special name used in place of kelvin. An interval or difference of Celsius temperature can, however, be expressed in kelvins as well was in degrees Celsius.

    mole: The mole is the amount of substance of a system which contains as many elementary entities as there are atoms in 0,012 kilograms of carbon-l 2. When the mole is used, the elementary entities must be specified -and may be atoms, molecules, ions, electrons, other particles, or specified groups of such particles.

    [14th CGPM (1971), Resolution 33

    candela: The candela is the luminous intensity, in a given direction, of a source that emits monochromatic radiation of frequency 540 x 1 012 hertz and that has a radiant intensity in that direction of l/683 watt per steradian.

    [16th CGPM (1979), Resolution 31

    22

  • (Continued from second cover)

    In term tional Standard

    IS0 31-6 : 1992

    IS0 31-7 : 1992

    IS0 31-8 : 1992

    IS0 31-9 : 1992

    IS0 31-10: 1992

    IS0 31-11 : 1992

    IS0 31-12 : 1992

    IS0 31-13 : 1992

    IS0 2955 : 1983

    corresponding Indian Standard

    IS 1890 (Part 6) : 1983) Quantities, units and symbols: Part 6 Light and related electromagnetic radiations

    IS 1890 (Part 7) : 1994 Quantities and units: Part 7 Acoustics (first revision)

    IS 1890 (Part 8) : 1994 Quantities and units: Part 8 Physical chemistry and molecular (first revision)

    IS 1890 (Part 9) : 1994 Quantities and units: Part 9 Atomicand nuclear physics (first revision)

    IS 1890 (Part 10) : 1994 Quantities and units: Part 10 Nuclear reactions and ionizing radiation (first revision)

    ISl890(Pattll): 1994Quantitiesand units: Part 11 Mathematical signs and symbols for use in the physical science and technology (second revision)

    IS1890(Part12):1994Quantitiesand units: Part 12 Characteristic number (first revision)

    IS 1890 (Part 13) : 1983l) Quantities, units and symbols: Part 13 Solid state physics

    IS 11366 : 1985 Representation of SI and other units in systems with limited characteristics for information processing

    Degree of Equivalence

    Technically equivalent

    Identical

    Identical

    Identical

    Identical

    Identical

    Identical

    Technically equivalent

    Identical

    ) Under Revision.

  • Bureau of Indian Standards

    BIS is a statutory institution established under the Bureau ofhfiun Stumfurds Act, 1986 to promote harmonious development of the activities of standardization, marking and quality certification of goods

    and attending to connected matters in the country.

    Copyright

    BIS has~the copyright of all its publications. No part of these publications may be reproduced in any form without the prior permission in writing of BIS. This does not preclude the free use, in the course of implementing the standard, of necessary details, such as symbols and sizes, type or grade designations. Enquiries relating to copyright be addressed to the Director (Publications), BIS.

    Review of Indian Standards

    Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewed periodically; a standard along with amendments is reaffirmed when such review indicates that no changes are needed; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standards should ascertain that they are in possession of the latest amendments or edition by referring to the latest issue of BIS Handbook and Standards Monthly Additions.

    This Indian Standard has been developed from Dot No. MSD 1(89)

    Amendments Issued Since Publication

    Amend No. Date of Issue Text Affected

    BUREAU OF INDIAN STANDARDS

    Headquarters:

    Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002 Telephones : 3310131,33113 75

    Regional Offices :

    Telegrams: Manaksanstha (Common to all offices)

    Telephone

    Central : Manak Bhavan, 9 Bahadur Shah Zafar Marg 3310131 : NEW DELHI 110002 331 13 75

    Eastern : l/14 C. LT. Scheme VII M, V. I. P. Road, Maniktola 37 84 99,37 85 61 CALCUTTA 700054 378626,378662

    Northern : SC0 335-336, Sector 34-A CHANDIGARH 160022 603843 602025

    Southern : C. I. T. Campus, IV Cross Road, MADRAS 600113 235 02 16,235 04 42 235 15 19,235 23 15

    Western : Manakalaya, E9 MIDC, Marol, Andheri (East) 632 92 95,632 78 58 BOMBAY 400093 632 78 91,632 78 92

    Branches : AHMADABAD. BANGALORE. BHOPAL. BHUBANESHWAR. COIMBATORE. FARIDABAD. GHAZIABAD. GUWAHATI. HYDERABAD. JAIPUR. KANPUR. ~LUCKNOW. PATNA THIRUVANANTHAPURAM.

    Printed at Simco Printing Pres, Delhi

    t: ( Reaffirmed 2005 )