I/O Wiring Conversion Systems PLC-5 1771 to ControlLogix 1756 Selection Guide

Upload: tranthuan

Post on 27-Oct-2018

223 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

I/O Wiring Conversion Systems PLC-5 1771 to ControlLogix 1756

Selection Guide

Page 2: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

I/O Wiring Conversion Systems

What’s Inside

Summary of ChangesThis publication contains new and updated information as indicated in the following table.

Topic Page

Product Selection 3

Approximate Dimensions 11

Wiring Diagrams - Digital Inputs 19

Wiring Diagrams - Digital Outputs 47

Wiring Diagrams - Analog Inputs and Outputs 77

Wiring Diagrams - High Resolution Isolated Analog 103

Topic Page

Analog Inputs and Outputs Product Selection - added new options for 1771-IL, 1771-OFE1 and 1771-OFE2 conversions

7

1771-N High Resolution Isolated Analog I/O Modules - New conversion options in standard and combination

8

Page 3: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Product Selection

1771 I/O to 1756 I/O Conversion Modules

I/O Conversion Modules provide a fast and efficient method for converting 1771 PLC-5 I/O to 1756 ControlLogix I/O. The I/O conversion is accomplished without removing any field wires from the existing swing arm, virtually removing the risk of wiring errors. The existing swing arms fit directly onto the edge connector of the conversion modules.

The cables are pre-wired and have a connector for the conversion module on one end and a removable terminal block (RTB) on the other end. The I/O signals are routed through the conversion module and the cable to the appropriate terminals on the I/O module.

The I/O Conversion System includes:• Conversion Modules (Ex: Cat No: 1492-CM1771-LD001)• Cables (Ex: Cat No: 1492-CONACAB005X)• Conversion Mounting Assembly (Ex: Cat No: 1492-MUA4-A13-A17)

Conversion Modules, Cables, and Mounting Assemblies

Conversion Modules Pre-wired Cables, 25-pin

Base Plate Cover PlateThe Conversion Modules are housed in a Conversion Mounting Assembly Base Plate. This base plate has the same footprint and mounting holes as the 1771 chassis. There is no need to drill and tap new mounting holes in the control cabinet.

The Conversion Mounting Assembly Cover Plate covers and helps protectthe Conversion Modules while providing a place to mount the new 1756 chassis. The Cover Plate has pre-drilled and tapped mounting holes allowing the new 1756 chassis to be mounted in several locations – centered, right-justified or left-justified. There is no need to drill and tap new mounting holes in the control cabinet.

Pre-wired Cables, 37-pin

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 3

Page 4: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Product Selection

Conversion Mounting Assembly Selection

Conversion Modules must be installed in a 1492 Conversion Mounting Assembly (see table below, a complete System Installation Manual is included with each assembly. Use the following steps to select the proper conversion mounting assembly:

1. Determine the quantity of each type of 1771 I/O modules used in the I/O chassis to be converted.

2. From the table below:a. Select the applicable 1492 conversion modules b. Review the Max Slots for I/O and Chassis Width data from the table belowc. Select a 1756 I/O chassis which has enough I/O slots. Two I/O slots are required in the 1756 chassis for conversions

where one 1771 I/O module converts to two 1756 I/O modules.d. Select the conversion mounting assembly which has enough conversion module slots.

(2) conversion module slots are required in the conversion mounting assembly for conversions where (2) 1771 I/O modules convert to (1) 1756 I/O modules.

The combined depth of the conversion mounting assembly with the 1756 chassis mounted on top is 10.25 inches (controller w/key) or 10.0 inches (controller w/o key). Dimension drawings are included in the System Installation Manual that ships with the Assembly.

Chassis Dimensions and Max Slot Information

1771 Chassis 1756 Chassis Conversion Mounting Assembly

Cat. No.Max Slots

for I/O

Chassis Width(2)

in (mm)

(2) Notice that the 1756 Chassis Width sometimes exceeds the 1771 Chassis Width, with or without the Power Supply. The Cover-Plate of the 1492 Conversion Mounting Assembly allows the 1756 Chassis to be Left justified, Right justified or Centered. A complete System Installation Manual ships with the 1492 Conversion Mounting Assembly.

Cat. No.Max Slots

for I/O

Chassis Width

in (mm) Cat. No.

Max Slots for Conversion

ModulesChassis Width

in (mm)

Without Power Supply

With Power Supply

1771-A1B 4 9.01 (229) 12.61 (320)1756-A4 3 10.35 (263)

1492-MUA1B-A4-A7 4 9.01 (229)1756-A7 6 14.49 (368)

1771-A2B 8 14.01 (356) 17.61 (447)1756-A7 6 14.49 (368)

1492-MUA2B-A7-A10 8 14.01 (356)1756-A10 9 19.02 (483)

1771-A3B1(1)

(1) 1771-A3B is not listed as it is used for 19 inch wide instrumentation panels.

12 19.01 (483)1756-A10 9 19.02 (483)

1492-MUA3B-A10-A13 12 19.01 (483)1756-A13 12 23.15 (588)

1771-A4B 16 24.01 (610)1756-A13 12 23.15 (588)

1492-MUA4-A13-A17 16 24.01 (610)1756-A17 16 29.06 (738)

4 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 5: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Product Selection

Digital Inputs

1. Column 1: find the Catalog Number of the 1771 Module you are converting from.

2. Column 2: find the Catalog Number of the compatible 1756 Module you are converting to. In some cases more than one module exists. Review the matrix carefully and review the I/O module Installation Manuals to determine full compatibility.

3. Column 3: find the Conversion Module catalog number and order quantity.

4. Column 4: find the Conversion Cable catalog number and order quantity.

1 2 3 4 5

Converting From 1771 Module(1)

(1) To understand any issues concerning I/O module compatibility refer to the conversion module wiring diagrams and the Installation Manuals for the specific I/O modules involved (with particular attention to the specification and wiring instructions).

Qty. Converting to 1756 Module Qty.

Conversion Module Conversion Cable(3)

(3) The 005 in the Cat. No. indicates cable length of the 1492 cable. The recommended length of 0.5 M is listed, additional lengths are listed below.

1.0M Cable = 1492-CONCAB010_, 1.0M/1.0M Cable= 1492-C010010X_,0.5M/1.0M Cable = 1492-C005010X_,1.0M/0.5M Cable = 1492-C010005X_

Wiring Diagram

Cat. No. Order Cat. No. Order Page

1771-IA 2 1756-IA16 1 1492-CM1771-LD007 2 1492-C005005XE 1 19

1771-IA2 2 1756-IA16 1 1492-CM1771-LD007 2 1492-C005005XE 1 19

1771-IAD 1 1756-IA16 1 1492-CM1771-LD001 1 1492-CONCAB005X 1 20

1771-IAD 1 1756-IH16I 1 1492-CM1771-LD002 1 1492-CONCAB005Y 1 21

1771-IAN 1 1756-IA32 1 1492-CM1771-LD003 1 1492-CONCAB005Z 1 22

1771-IB 2 1756-IB16 1 1492-CM1771-LD007 2 1492-C005005XE 1 23

1771-IBD 1 1756-IB16 1 1492-CM1771-LD001 1 1492-CONCAB005X 1 24

1771-IBN 1 1756-IB32 1 1492-CM1771-LD003 1 1492-CONCAB005Z 1 25

1771-IC 2 1756-IC16 1 1492-CM1771-LD007 2 1492-C005005XE 1 26

1771-ICD 1 1756-IC16 1 1492-CM1771-LD001 1 1492-CONCAB005X 1 27

1771-ID 2 1756-IA16I 1 1492-CM1771-LD012 2 1492-C005005XL 1 28

1771-ID01 2 1756-IM16I 1 1492-CM1771-LD012 2 1492-C005005XL 1 29

1771-ID16 1 1756-IA16I 1 1492-CM1771-LD004 1 1492-CONCAB005Y 1 30

1771-ID16 1 1756-IH16I 1 1492-CM1771-LD004 1 1492-CONCAB005Y 1 31

1771-IG 2 1756-IG16 1 1492-CM1771-LA003(2)

(2) These 1771 Digital I/O Modules use a Swing Arm that only mounts to these Analog I/O Conversion Modules, which will therefore be used to provide for these 1771 Digital I/O conversions.

2 1492-C005005XS 1 32

1771-IGD 1 1756-IG16 1 1492-CM1771-LD006 1 1492-CONCAB005X 1 33

1771-IH 2 1756-IC16 1 1492-CM1771-LD007 2 1492-C005005XE 1 34

1771-IM 2 1756-IM16I 1 1492-CM1771-LD007 2 1492-C005005XH 1 35

1771-IMD 1 1756-IM16I 1 1492-CM1771-LD002 1 1492-CONCAB005Y 1 36

1771-IN 2 1756-IN16 1 1492-CM1771-LD007 2 1492-C005005XE 1 37

1771-IND 1 1756-IN16 1 1492-CM1771-LD001 1 1492-CONCAB005X 1 38

1771-IND1 1 1756-IN16 1 1492-CM1771-LD001 1 1492-CONCAB005X 1 39

1771-IQ 2 1756-IB16I 1 1492-CM1771-LD007 2 1492-C005005XK 1 40

1771-IQ 2 1756-IB16I 1 1492-CM1771-LD014 2 1492-C005005XJ 1 41

1771-IQ16 1 1756-IB16I 1 1492-CM1771-LD004 1 1492-CONCAB005Y 1 42

1771-IT 2 1756-IB16 1 1492-CM1771-LD007 2 1492-C005005XE 1 43

1771-IV 2 1756-IV16 1 1492-CM1771-LD014 2 1492-C005005XG 1 44

1771-IVN 1 1756-IV32 1 1492-CM1771-LD005 1 1492-CONCAB005Z 1 45

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 5

Page 6: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Product Selection

Digital Outputs

1. Column 1: find the catalog number of the 1771Module you are converting from.

2. Column 2: find the catalog number of the compatible 1756 Module you are converting to. In some cases more than one module exists. Review the matrix carefully and review the I/O module Installation Manuals to determine full compatibility.

3. Column 3: find the catalog number of the Conversion Module.

4. Column 4: find the catalog number of the Conversion Cable.

1 2 3 4 5

Converting from 1771 Module(1)

(1) To understand any issues concerning I/O module compatibility refer to the conversion module wiring diagrams and the Installation Manuals for the specific I/O modules involved (with particular attention to the specification and wiring instructions).

Converting to 1756 Module Conversion Module Conversion Cable(4)

(4) The 005 in the Cat. No. indicates cable length of the 1492 cable. The recommended length of 0.5 M is listed, additional lengths are listed below.

1.0M Cable = 1492-CONCAB010_, 1.0M/1.0M Cable= 1492-C010010X_0.5M/1.0M Cable = 1492-C005010X_, 1.0M/0.5M Cable = 1492-C010005X_

Wiring Diagram

Cat. No. Qty. Cat. No. Qty.(2)

(2) Where two is indicated, these modules need to be located directly next to each other in the 1756 chassis.

Cat. No. (3)

(3) An “F” at the end of the 1756 catalog number indicates that it is fused to match the functionality of the 1771 module being replaced.

Order Qty. Cat. No. Order Qty. Page

1771-OA 1 1756-OA8E 1 1492-CM1771-LD014 1 1492-CONCAB005U 1 47

1771-OAD 1 1756-OA16 1 1492-CM1771-LD006 1 1492-CONCAB005X 1 48

1771-OAN 1 1756-OA16 2 1492-CM1771-LD013 1 1492-CONCAB005S3 1 49

1771-OB 2 1756-OB16D 1 1492-CM1771-LD014 2 1492-C005005XF 1 50

1771-OBD 1 1756-OB16E 1 1492-CM1771-LD006 1 1492-CONCAB005X 1 51

1771-OBD 1 1756-OC8 2 1492-CM1771-LD008F 1 1492-CONCAB005S1 1 52

1771-OBDS 1 1756-OB16E 1 1492-CM1771-LD006 1 1492-CONCAB005X 1 53

1771-OBN 1 1756-OB32 1 1492-CM1771-LD009F 1 1492-CONCAB005Z 1 54

1771-OC 1 1756-OC8 1 1492-CM1771-LD014 1 1492-CONCAB005V 1 55

1771-OD 2 1756-OA16I 1 1492-CM1771-LD012 2 1492-C005005XM 1 56

1771-OD16 1 1756-OA16I 1 1492-CM1771-LD010F 1 1492-CONCAB005Y 1 57

1771-ODD 1 1756-OA16I 1 1492-CM1771-LD010F 1 1492-CONCAB005Y 1 58

1771-ODZ 2 1756-OA16I 1 1492-CM1771-LD012 2 1492-C005005XP 1 59

1771-OG 2 1756-OG16 2 1492-CM1771-LA003 2 1492-C005005XS 1 60

1771-OGD 1 1756-OG16 2 1492-CM1771-LD006 1 1492-CONCAB005X 1 61

1771-OM 2 1756-OA16 1 1492-CM1771-LD014 2 1492-C005005XG 1 62

1771-OMD 1 1756-OA16 1 1492-CM1771-LD006 1 1492-CONCAB005X 1 63

1771-ON 1 1756-ON8 1 1492-CM1771-LD014 1 1492-CONCAB005W 1 64

1771-OND 1 1756-ON8 2 1492-CM1771-LD006 1 1492-CONCAB005S2 1 65

1771-OQ 2 1756-OB16I 1 1492-CM1771-LA004 2 1492-C005005XT 1 66

1771-OQ16 1 1756-OB16I 1 1492-CM1771-LD010F 1 1492-CONCAB005Y 1 67

1771-OR 2 1756-OA16I 1 1492-CM1771-LD012 2 1492-C005005XR 1 68

1771-OVN 1 1756-OV16E 2 1492-CM1771-LD013 1 1492-CONCAB005S3 1 69

1771-OW 1 1756-OX8I 1 1492-CM1771-LD012 1 1492-CONCAB005Y 1 70

1771-OW16 1 1756-OW16I 1 1492-CM1771-LD011 1 1492-CONCAB005Y 1 71

1771-OWNA 1 1756-OW16I 2 1492-CM1771-LD013 1 1492-CONCAB005S4 1 72

1771-OY 1 1756-OX8I 1 1492-CM1771-LD012 1 1492-CONCAB005Y 1 73

1771-OYL 1 1756-OX8I 1 1492-CM1771-LD012 1 1492-CONCAB005Y 1 74

1771-OZ 1 1756-OX8I 1 1492-CM1771-LD012 1 1492-CONCAB005Y 1 75

1771-OZL 1 1756-OX8I 1 1492-CM1771-LD012 1 1492-CONCAB005Y 1 76

6 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 7: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Product Selection

Analog Inputs and Outputs

1. Column 1: find the catalog number of the 1771Module you are converting from.

2. Column 2: find the catalog number of the compatible 1756 Module you are converting to. In some cases more than one module exists. Review the matrix carefully and review the I/O module Installation Manuals to determine full compatibility.

3. Column 3: find the catalog number of the Conversion Module.

4. Column 4: find the catalog number of the Conversion Cable.

1 2 3 4 5

Converting from 1771 Module Converting to 1756 Module Conversion Module Conversion Cable Wiring Diagram

Cat. No. Qty. Cat. No. Description Qty. Cat. No. Order Qty. Cat. No. Order Qty. Page

1771-IFE 1 1756-IF16

Differential Current 1 1492-CM1771-LA002 1 1492-CONACAB005D 1 77

Differential Voltage 1 1492-CM1771-LA002 1 1492-CONACAB005C 1 78

Single End Current 1 1492-CM1771-LA001 1 1492-CONACAB005B 1 79

Single End Voltage 1 1492-CM1771-LA001 1 1492-CONACAB005A 1 80

1771-IFF 1 1756-IF16

Differential Current 1 1492-CM1771-LA002 1 1492-CONACAB005D 1 81

Differential Voltage 1 1492-CM1771-LA002 1 1492-CONACAB005C 1 82

Single End Current 1 1492-CM1771-LA001 1 1492-CONACAB005B 1 83

Single End Voltage 1 1492-CM1771-LA001 1 1492-CONACAB005A 1 84

1771-IL 1

1756-IF8ICurrent 1 1492-CM1771-LA004 1 1492-CONACAB005K8 1 85

Voltage 1 1492-CM1771-LA004 1 1492-CONACAB005L8 1 86

1756-IF6I (6-ch)

Current 1 1492-CM1771-LA004 1 1492-CONACAB005K 1 87

Voltage 1 1492-CM1771-LA004 1 1492-CONACAB005L 1 88

1756-IF6I (2x 4-ch)

Current 2 1492-CM1771-LA004 1 1492-CONACAB005T1 1 89

Voltage 2 1492-CM1771-LA004 1 1492-CONACAB005T2 1 90

1771-IR 11756-IRT8I RTD 1 1492-CM1771-LA004 1 1492-CONACAB005F8 1 91

1756-IR6I RTD 1 1492-CM1771-LA004 1 1492-CONACAB005F 1 92

1771-IXE 11756-IT6I2 Thermocouple 1 1492-CM1771-LA005 1 1492-CONACAB005G 1 93

1756-IRT8I Thermocouple 1 1492-CM1771-LA005 1 1492-CONACAB005G8 1 94

1771-IXHR 11756-IT6I2 Thermocouple 1 1492-CM1771-LA005 1 1492-CONACAB005G 1 95

1756-IRT8I Thermocouple 1 1492-CM1771-LA005 1 1492-CONACAB005G8 1 96

1771-OFE1

1 1756-OF6VI Voltage 1 1492-CM1771-LA003 1 1492-CONACAB005E 1 97

1 1756-OF8I Voltage 1 1492-CM1771-LA003 1 1492-CONACABOO5E8V 1 98

2 1756-OF8I Voltage 1 1492-CM1771-LA003 2 1492-C005005E8V 1 99

1771-OFE2

1 1756-OF6CI Current 1 1492-CM1771-LA003 1 1492-CONACAB005E 1 100

1 1756-OF8I Current 1 1492-CM1771-LA003 1 1492-CONACABOO5E8C 1 101

2 1756-OF8I Current 1 1492-CM1771-LA003 2 1492-C005005E8C 1 102

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 7

Page 8: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Product Selection

1771-N High Resolution Isolated Analog I/O Modules

The 1771-N High Resolution Analog I/O modules are designed for use with 1771-RTPs (Remote Termination Panels) and connected by a 6 or 15 foot cable (Cat. No. 1771-NC6 or 1771-NC15). The conversion of the 1771-N Series I/O to a 1756 ControlLogix I/O can be accomplished without the removal of any field wires from the existing 1771-RTPs.

Simply replace the (2) existing 1771 cables with (2) of the following cables in the table below. Each of these cables has a connector on one end that attaches directly to the existing 1771-RTP and a 1756 RTB (Removable Terminal Block) on the other end for connection to the ControlLogix I/O module.

Use the following steps to select the proper conversion cables:

1. Column 2: find the catalog number of the 1771 Digital I/O module.

2. In column 3, find the catalog number of the compatible 1756 Digital I/O module. In some cases more than one module is required. Review the matrix and the I/O module installation manuals to determine full compatibility

3. In column 4, find the catalog numbers and descriptions of the appropriate cables.

1 2 3 4 5

I/O DescriptionConvert From: Convert To:

Cable DescriptionConversion Cable Catalog Number Wiring

Diagram Page

1771 Module Qty. 1756

Module Qty. Cable "A" Cable "B"

Standard 1771-N High Resolution I/O

1771-NOC

1 1756-OF8I 1 Current (8 Ch) 1492-CONACAB020N88 103

1 1756-OF8 1 Current (8 CH) 1492-CONACAB020N8 104

1 1756-OF6CI 2 Current (4/4 CH) 1492-CONACAB020N1 1492-CONACAB020N1 105

1771-NIS1 1756-IF8I 1 Current (8 CH) 1492-CONACAB020N38 106

1 1756-IF6CIS 2 Current (4/4 CH) 1492-CONACAB020N2 1492-CONACAB020N2 107

1771-NIV

1 1756-IF8I 1 Current (8 CH) 1492-CONACAB020N38 108

1 1756-IF6I 2 Current (4/4 CH) 1492-CONACAB020N3 1492-CONACAB020N3 109

1 1756-IF8I 1 Voltage (8 CH) 1492-CONACAB020N78 110

1 1756-IF6I 2 Voltage (4/4 CH) 1492-CONACAB020N7 1492-CONACAB020N7 111

1 1756-IF6I 2 Current (A - 4 CH) /Voltage (B - 4 CH)

1492-CONACAB020N3 1492-CONACAB020N7 112

1 1756-IF6I 2Voltage (A - 4 CH) / Current (B - 4 CH) 1492-CONACAB020N7 1492-CONACAB020N3 113

1771-NR1 1756-IRT8I 1 RTD (8 CH) 1492-CONACAB020N48 114

1 1756-IR6I 2 RTD (4/4 CH) 1492-CONACAB020N4 1492-CONACAB020N4 115

1771-NT11 1756-IRT8I 1 Thermocouple (8 CH) 1492-CONACAB020N68 116

1 1756-IT6I 2 Thermocouple (4/4 CH) 1492-CONACAB020N5 1492-CONACAB020N5 117

1771-NOV1 1756-OF8I 1 Voltage (8 CH) 1492-CONACAB020N18 118

1 1756-OF6VI 2 Voltage (4/4 CH) 1492-CONACAB020N5 1492-CONACAB020N1 119

1771-NIV11 1756-IF8I 1 Voltage (8 CH) 1492-CONACAB020N78 120

1 1756-IF6I 2 Voltage (4/4 CH) 1492-CONACAB020N7 1492-CONACAB020N7 121

1771-NT21 1756-IRT8I 1 Thermocouple (8 CH) 1492-CONACAB020N68 122

1 1756-IT6I2 2 Thermocouple (4/4 CH) 1492-CONACAB020N6 1492-CONACAB020N6 123

8 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 9: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Product Selection

Specifications

Combination 1771-N High Resolution I/O

1771-NIVR

1

1756-IRT8I

1

RTD (4 CH) - 1492-CONACAB020N44124

1756-IF8I Voltage (4 CH) 1492-CONACAB020N74 -

1756-IR6I RTD (4 CH) - 1492-CONACAB020N4125

1756-IF6I Voltage (4 CH) 1492-CONACAB020N7 -

1756-IRT8I RTD (4 CH) - 1492-CONACAB020N44126

1756-IF8I Current (4 CH) 1492-CONACAB020N34 -

1756-IR6I RTD (4 CH) - 1492-CONACAB020N4127

1756-IF6I Current (4 CH) 1492-CONACAB020N3 -

1771-NIVT

1756-IRT8I Thermocouple (4 CH) - 1492-CONACAB020N54128

1756-IF8I Voltage (4 CH) 1492-CONACAB020N74 -

1756-IT6I Thermocouple (4 CH) - 1492-CONACAB020N5129

1756-IF6I Voltage (4 CH) 1492-CONACAB020N7 -

1756-IRT8I Thermocouple (4 CH) - 1492-CONACAB020N54130

1756-IF8I Current (4 CH) 1492-CONACAB020N34 -

1756-IT6I Thermocouple (4 CH) - 1492-CONACAB020N5131

1756-IF6I Current (4 CH) 1492-CONACAB020N3 -

Attribute Value

Dimensions (H x D x W) 300 x 111.25 x 38.1 mm (11.81 x 4.38 x 1.5 in.)

Approximate Shipping Weight 260g (0.57 lb)

Storage Temperature Storage Temperature -40...+85 °C (-40...+185 °F)

Operating Temperature Operating Temperature 0...+60 °C (+32...+140 °F)

Operating Humidity Operating Humidity 5...95% at +55 °C (+131 °F)

ShockNonoperating 50 g

Operating 30 g

Operational Vibration 2 g at 10...500 Hz

Agency Certifications UL Classified (UL File No. E113724)

CE Certifications Compliant for all applicable directives

Pollution Degree 2

Environmental Rating IP20

1 2 3 4 5

I/O DescriptionConvert From: Convert To:

Cable DescriptionConversion Cable Catalog Number Wiring

Diagram Page

1771 Module Qty. 1756

Module Qty. Cable "A" Cable "B"

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 9

Page 10: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Product Selection

Notes:

10 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 11: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Approximate Dimensions

Dimensions are in. (mm).

Cat No. MUA1B-A4-A7 used with Cat No. 1756-A4

9.0[229.6 ]

11.1[281.7 ]

12.5[317.2 ]

5.4[137 ]

10.4[263.6 ]

6.1[154 ]

9.9[251.9 ]

11.1[281.7 ]

12.5[317.2 ]

2.4[60.1 ]

5.4[137 ]

2.4[60.2 ]

9.1[230.7 ]

10.4[264.1 ]

Left Justified

Right Justified

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 11

Page 12: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Approximate Dimensions

Cat No. MUA1B-A4-A7 used with Cat No. 1756-A7

9.9[251.9 ]

6.1[154 ]

9.0[229.6 ]]

2.4[60.2 ]]

12.5[317.2 ]

5.4[136.5 ]]

14.6[370.6 ]

11.1[281.7 ]

9.0[229.6 ]

4.1[104.5 ]

2.4[60.2 ]

12.5[317.2 ]

14.6[370.1 ]

5.4[137.3 ]

14.6[370.1 ]

9.1[231.9 ]

2.4[60.2 ]

12.5[317.2 ]

11.1[281.7 ]

5.4[137.3 ]

2.4[60.2 ]

Left Justified

Centered

Right Justified

12 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 13: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Approximate Dimensions

Cat No. MUA2B-A7-A10 used with Cat No. 1756-A7

11.1[281.7 ]

12.5[317.3 ]

14.0[356.6 ]

.2[5.7 ]

2.4[59.7 ]

.3[7.8 ]

14.6[370.1 ]

5.4[136 ]

9.9[251.9 ]

6.1[154 ]

Centered

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 13

Page 14: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Approximate Dimensions

Cat No. MUA3-A10-A13 used with Cat No. 1756-A10

19.0[483.6 ]

2.4[60.2 ]

12.5[317.3 ]

5.4[137 ]

11.1[281.7 ]

19.2[486.9 ]

6.1[154.4 ]

9.9[252.3 ]

Centered

14 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 15: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Approximate Dimensions

Cat No. MUA3-A10-A13 used with Cat No. 1756-A13

23.2[588 ]

2.4[60.2 ]

5.4[137 ]

.7[18 ]

19.0[483.6 ]

12.5[317.3 ]

11.1[281.7 ]

2.2[56.8 ]

1.9[47.4 ]

2.4[59.9 ]

19.0[483.6 ]23.2[588 ]

11.2[285.6 ]

23.2[588 ]

4.1[103.1 ]

2.4[60.2 ]

5.4[137 ] 11.1

[281.7 ]

9.6[243.9 ]

5.7[146 ]

5.4[137 ]

Left Justified

Centered

Right Justified

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 15

Page 16: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Approximate Dimensions

Cat No. MUA4-A13-A17 used with Cat No. 1756-A13

2.4[60.2 ]

24.0[610.6 ]

23.2[588 ]

12.5[316.7 ]

11.1[281.7 ]

5.4[137 ]

9.6[243.7 ]

5.7[145.9 ]

Centered

16 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 17: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Approximate Dimensions

Cat No. MUA4-A13-A17 used with Cat No. 1756-A17

29.1[737.9 ]

24.0[610.6 ]

.2[6.2 ]

2.4[60.1 ]

4.8[121 ]

12.5[316.7 ]

11.1[281.7 ]

3.6[91.7 ]2.4

[60.1 ]

5.4[137 ]

1.4[35.6 ]

12.5[316.7 ]

11.1[281.7 ]

24.0[610.6 ]

5.1[130 ].4

60.1 ]

5.4[137 ]

11.1[281.7 ]

12.5[316.7 ]

24.0[610.6 ]

29.1[737.9 ]

29.1[737.9 ]

6.1[154 ]

9.9[251.9 ]

Left Justified

Centered

Right Justified

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 17

Page 18: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Approximate Dimensions

Notes:

18 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 19: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IA, IA2 to 1756-IA16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IA16 RTB. Recommended cablelengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths.

� The 1771-IA, -IA2 module is rated 87V to 138V AC and 97V to 138V DC. The 1756-IA16 module is rated 79V to 132V AC only.

� Refer to your 1771-IA, -IA2 and 1756-IA16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-952 (Version 02)]

� The input delay times for the 1771-IA, -IA2 module versus the 1756-IA16 module are as follows: 1771-IA, -IA2 1756-IA16 w/ 1492-C005005XEa) Off-to-On Delay 24ms (+/-10ms) 10ms max (plus selectable filter)b) On-to-Off Delay 24ms (+/-10ms) 8ms max (plus selectable filter)

Conversion Module Installation and Application Considerations

B

34567

A

1771-WA Swing ArmFrom 1771-IA , -IA2

1771-WA Swing ArmFrom 1771-IA , -IA2

012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

1

19

345678910111213

15161718

20

14

2

24

212223

25

L1

L2

10L2-0

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

L2-120

9L2-0

19L2-1

CABLE “A”

CABLE “B”

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7L2

B

34567

A012

1

19

345678910111213

15161718

20

14

2

24

212223

25

L1

L2

Not used

Input 8Input 9

Input 10Input 11Input 12Input 13

Input 14

Input 15L2

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

Conversion Module1492-CM1771-LD007

Conversion Module1492-CM1771-LD007

Cable1492-C005005XE� 1756-IA16

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 19

Page 20: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IAD to 1756-IA16

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-IA16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The input delay times for the 1771-IAD module versus the 1756-IA16 module are as follows: 1771-IAD 1756-IA16 w/ 1492-CONCAB005Xa) Off-to-On Delay 5ms (+/-3ms) @120VAC 10ms max (plus selectable filter)b) On-to-Off Delay 25ms (+/-5ms) 8ms max (plus selectable filter)

� The 1771-IAD module is rated 79V to 138V AC or DC. The 1756-IA16 module is rated 74V to 132V AC. If the inputsource voltage is DC use a 1756-IH16l and 1492-CM1771-LD002 conversion module.

� Refer to your 1771-IAD and 1756-IA16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-925 (Version 02)]

10L2-0

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenL2-1

20

9L2-0

19L2-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Input 14

Input 16Input 15

Input 17

Input 04

Input 06Input 05

Input 07

Input 00

Input 02Input 01

Input 03

Input 10

Input 12Input 11

Input 13

Terminal A

Terminal E

BCD

Terminal BTerminal CTerminal D

L1

L2

24

212223

25

1756-IA16

1771-WH Swing ArmFrom 1771-IAD

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module1492-CM1771-LD001

Cable1492-CONCAB005X�

IMPORTANT

20 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 21: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IAD to 1756-IH16I

1756-IH16I

1771-WH Swing ArmFrom 1771-IAD

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

Conversion Module Installation and Application Considerations� The input delay times for the 1771-IAD module versus 1756-IH16I module are as follows: 1771-IAD 1756-IH16Ia) Off-to-On Delay 3ms @120V DC 2ms (plus selectable filter)b) On-to-Off Delay 25ms (+/-5ms) 6ms (plus selectable filter)� The 1771-IAD module is rated 79V to 138V AC or DC. The 1756-IH16I module is rated 90V to 146V DC. If the inputspurce voltage is AC use a 1756-IA16 and 1492-CM1771-LD002 conversion module.� Refer to your 1771-IAD and 1756-IH16I Installation Manual wiring schematics and diagrams for more details.

[Reference Doc: 41170-927 (Version 02)]

A

00

01

02

03

04

05

06

07

E

10

11

12

13

14

15

16

17

Input 14

Input 16

Input 15

Input 17

Input 04

Input 06

Input 05

Input 07

Input 00

Input 02

Input 01

Input 03

Input 10

Input 12

Input 11

Input 13

Terminal A

Terminal E

BCD

Terminal BTerminal CTerminal D

+

-

12345678910111213

151617181920

14

21222324252627282930313233

353637

34

IN-0

21

IN-1

43

IN-2

65

IN-3

87

IN-4

109

IN-5

1211

IN-6

1413

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenIN-7

1615

IN-8

1817

IN-9

2019

IN-10

2221

IN-11

2423

IN-12

2625

IN-13

2827

IN-14

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueIN-15

3231

GND-0

GND-1

GND-2

GND-3

GND-4

GND-5

GND-6

GND-7

GND-8

GND-9

GND-10

GND-11

GND-12

GND-13

GND-14

GND-15

Conversion Module1492-CM1771-LD002

Cable1492-CONCAB005Y�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 21

Page 22: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IAN to 1756-IA32

1771-WN Swing ArmFrom 1771-IAN

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

Conversion Module Installation and Application Considerations� The input delay times for the 1771-IAN module versus 1756-IA32 module are as follows: 1771-IAN 1756-IA32

a) Off-to-On Delay 10ms (+/-7ms) 10ms max (plus selectable filter)b) On-to-Off Delay 20ms (+/-15ms) 8ms max (plus selectable filter)

� The 1771-IAN has 4 groups(allowing 4 seperate power supplies) and the 1756-IA32 has 2 groups. This module/cable combination ties Groups 0 & 1 from the 1771-IAN to Group 0 on the 1756-IA32 and it ties Groups 2 & 3 from the 1771-IAN to Group 1 on the 1756-IA32. Field wiring modification must be made to accommodate this if multiple supplies were used. If 4 supplies were used, 2 must be removed.

� Refer to your 1771-IAN and 1756-IA32 Installation Manual wiring schematics and diagrams for more details.

1756-IA32

18L2-0

IN-01

IN-1619

IN-12

IN-1720

IN-23

IN-1821

IN-34

IN-1922

IN-45

IN-2023

IN-56

IN-2124

IN-67

IN-2225

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/RedRed/Green

IN-78

1234

3

5

226

4

7

238

5

9

2410

6

11

2512

7

13

26

8

15

2716

9

17

2818

10

1920

14

12

213122

13233224

14

253326

15273428

16293530

17313632

18

3337

30

353836

2

37

34

L2-136

IN-2326

IN-89

IN-2427

IN-910

IN-2528

IN-1011

IN-2629

IN-1112

IN-2730

IN-1213

IN-2831

IN-1314

IN-2932

IN-1415

IN-3033

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

IN-1516

IN-313417

L2-0White/Red/Blue

L2-13519

21

11

Common 0

1

39

2029

40

Common 2

L1

L2

Input 01Input 01Input 02Input 02Input 03Input 03Input 04Input 04

Input 05Input 05Input 06Input 06Input 07Input 07

Input 10

Input 11

Input 10

Input 12

Input 13Input 13Input 14Input 14Input 15Input 15Input 16Input 16Input 17Input 17

Input 00Input 00

Input 11

Input 12

Common 0Common 1Common 1Common 2

Common 3Common 3

Conversion Module1492-CM1771-LD003

Cable1492-CONCAB005Z�

IMPORTANT

22 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 23: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IB to 1756-IB16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

B

34567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

1

19

345678910111213

15161718

20

14

2

24

212223

25

+

-

1756-IB16

10GND-0

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

GND-120

9GND-0

19GND-1

CABLE “A”

CABLE “B”

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7GND-1

B

34567

A012

1

19

345678910111213

15161718

20

14

2

24

212223

25

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7GND-1

� The 1771-IB module is rated 24V DC. The 1756-IB16 module is rated 10 - 31V DC only.

� Refer to your 1771-IB and 1756-IB16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-995 (Version 00)]

� The input delay times for the 1771-IB module versus the 1756-IB16 module are as follows: 1771-IB 1756-IB16 w/ 1492-C005005XEa) Off-to-On Delay 24ms (+/-10ms) 1ms max (plus selectable filter)b) On-to-Off Delay 24ms (+/-10ms) 2ms max (plus selectable filter)

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

+

-

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IB16 RTB. Recommended cablelengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths.

1771-WA Swing ArmFrom 1771-IB

1771-WA Swing ArmFrom 1771-IB

Conversion Module1492-CM1771-LD007

Conversion Module1492-CM1771-LD007

Cable1492-C005005XE�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 23

Page 24: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IBD to 1756-IB16

1756-IB16

10GND-0

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenGND-1

20

9GND-0

19GND-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Input 14

Input 16Input 15

Input 17

Input 04

Input 06Input 05

Input 07

Input 00

Input 02Input 01

Input 03

Input 10

Input 12Input 11

Input 13

Terminal A

Terminal E

BCD

Terminal BTerminal CTerminal D

+

-

24

212223

25

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-IB16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The input delay times for the 1771-IBD module versus the 1756-IB16 module are as follows: 1771-IBD 1756-IB16 w/ 1492-CONCAB005Xa) Off-to-On Delay 1ms 1ms (plus selectable filter)b) On-to-Off Delay 1ms 2ms (plus selectable filter)

� Refer to your 1771-IBD and 1756-IB16 Installation Manual wiring Schematics and diagrams for more details. [Reference Doc: 41170-926 (Version 02)]

1771-WH Swing ArmFrom 1771-IBD

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module1492-CM1771-LD001

Cable1492-CONCAB005X�

IMPORTANT

24 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 25: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IBN to 1756-IB32

1771-WN Swing ArmFrom 1771-IBN

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1756-IB32

18GND-0

IN-01

IN-1619

IN-12

IN-1720

IN-23

IN-1821

IN-34

IN-1922

IN-45

IN-2023

IN-56

IN-2124

IN-67

IN-2225

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/RedRed/Green

IN-78

1234

3

5

226

4

7

238

5

9

2410

6

11

2512

7

13

26

8

15

2716

9

17

2818

10

1920

14

12

213122

13233224

14

253326

15273428

16293530

17313632

18

3337

30

353836

2

37

34

GND-136

IN-2326

IN-89

IN-2427

IN-910

IN-2528

IN-1011

IN-2629

IN-1112

IN-2730

IN-1213

IN-2831

IN-1314

IN-2932

IN-1415

IN-3033

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

IN-1516

IN-313417

GND-0White/Red/Blue

GND-135

Input 01Input 01Input 02Input 02Input 03Input 03Input 04Input 04

Input 05Input 05Input 06Input 06Input 07Input 07

Input 10

Input 11

Input 10

Input 12

Input 13Input 13Input 14Input 14Input 15Input 15Input 16Input 16Input 17Input 17

Input 00

19

21

11

dc Common 0

1Input 00

Input 11

Input 12

39

2029

40

+

-

dc Common 2

dc Common 0dc Common 1dc Common 1

dc Common 3dc Common 2

dc Common 3

Conversion Module Installation and Application Considerations� The input delay times for the 1771-IBN module versus 1756-IB32 module are as follows: 1771-IBN 1756-IB32

a) Off-to-On Delay 6ms (+/-2ms) 1ms (plus selectable filter)b) On-to-Off Delay 6ms (+/-2ms) 1ms (plus selectable filter)

� The 1771-IBN has 4 groups(allowing 4 seperate power supplies) and the 1756-IB32 has 2 groups. This module/cable combination ties Groups 0 & 1 from the 1771-IBN to Group 0 on the 1756-IB32 and it ties Groups 2 & 3 from the 1771-IBN to Group 1 on the 1756-IB32. Field wiring modification must be made to accommodate this if multiple supplies were used. If 4 supplies were used, 2 must be removed.

� Refer to your 1771-IBN and 1756-IB32 Installation Manual wiring schematics and diagrams for more details.

Conversion Module1492-CM1771-LD003

Cable1492-CONCAB005Z�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 25

Page 26: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IC to 1756-IC16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

B

34567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

1

19

345678910111213

15161718

20

14

2

24

212223

25

+

-

10GND-0

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

GND-120

9GND-0

19GND-1

CABLE “A”

CABLE “B”

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7GND-1

B

34567

A012

1

19

345678910111213

15161718

20

14

2

24

212223

25

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7GND-1

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

+

-

� The 1771-IC module is rated 42 to 56V DC. The 1756-IC16 module is rated 42 to 56V DC only.

� Refer to your 1771-IC and 1756-IC16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-996 (Version 00)]

� The input delay times for the 1771-IC module versus the 1756-IC16 module are as follows: 1771-IC 1756-IC16 w/ 1492-C005005XEa) Off-to-On Delay 12ms (+/-7ms) 1ms max (plus selectable filter)b) On-to-Off Delay 20ms (+/-7ms) 4ms max (plus selectable filter)

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IC16 RTB. Recommended cablelengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths.

1771-WA Swing ArmFrom 1771-IC

1771-WA Swing ArmFrom 1771-IC

1756-IC16 Conversion Module1492-CM1771-LD007

Conversion Module1492-CM1771-LD007

Cable1492-C005005XE�

IMPORTANT

26 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 27: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-ICD to 1756-IC16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

10RTN

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenRTN

20

9RTN

19RTN

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Input 14

Input 16Input 15

Input 17

Input 04

Input 06Input 05

Input 07

Input 00

Input 02Input 01

Input 03

Input 10

Input 12Input 11

Input 13

Terminal A

Terminal E

BCD

Terminal BTerminal CTerminal D

� The 1771-ICD module is rated 20V to 60V AC or DC. The 1756-IC16 module is rated 30V to 60V DC.

� This Bul. 1492 cable consists of a cable wired to one 1756-IC16 RTB. Recommended cable lengths of0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� Refer to your 1771-ICD and 1756-IC16 Installation Manual wiring schematics and diagrams for more details.

1771-WH Swing ArmFrom 1771-ICD

� The input delay times for the 1771-ICD module versus the 1756-IC16 module are as follows: 1771-ICD 1756-IC16 w/ 1492-CONCAB005Xa) Off-to-On Delay 6ms (+/-2ms) 1ms max (plus selectable filter)b) On-to-Off Delay 20ms (+/-1ms) 4ms max (plus selectable filter)

+

24

212223

25

Conversion Module Installation and Application Considerations

--

Conversion Module1492-CM1771-LD001

Cable1492-CONCAB005X� 1756-IC16

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 27

Page 28: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-ID to 1756-IA16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations � This Bul. 1492 cable consists of a cable wired to one 1756-IA16I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The input delay times for the 1771-ID module versus the 1756-IA16I module are as follows: 1771-ID 1756-IA16I w/ 1492-C005005XL a) Off-to-On Delay 24ms (+/-10ms) 10ms max (plus selectable filter) b) On-to-Off Delay 24ms (+/-10ms) 8ms max (plus selectable filter)

� The 1771-ID module had a jumper selection of N.O. and N.C. outputs. The 1756-IA16I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-ID jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4.

� Refer to your 1771-ID and 1756-IA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41170-993 (Version 00)]

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

LOAD

123456

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

7891011

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

12

L1L21

56789101112

234

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenOrange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

1

56789101112

234

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

252627282930313233343536

NOT USED

NOT USEDNOT USED

131415161718192021222324

L1-6L2-6L1-7

L2-7L1-8L2-8

L2-9L1-9

L2-10L1-10

L1-11L2-11

NOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USED

L1-0

L2-0

L1-1L2-1L1-2L2-2

L2-3L1-3

L2-4L1-4

L1-5L2-5

LOADL1L2

L1-6

L2-6

L1-7L2-7L1-8L2-8

L2-9L1-9

L2-10L1-10

L1-11L2-11

L1-0L2-0L1-1L2-1L1-2L2-2

L2-3L1-3

L2-4L1-4

L1-5L2-5

CABLE”A”

CABLE”B”NOT USED

Conversion Module1492-CM1771-LD012

Conversion Module1492-CM1771-LD012

1771-WD Swing ArmFrom 1771-ID

1771-WD Swing ArmFrom 1771-ID

Cable1492-C005005XL� 1756-IA16I

IMPORTANT

28 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 29: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-ID01 to 1756-IM16IThere are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module1492-CM1771-LD012

Conversion Module1492-CM1771-LD012

1771-WD Swing ArmFrom 1771-ID01

1771-WD Swing ArmFrom 1771-ID01

Cable1492-C005005XL� 1756-IM16I

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

LOAD

123456

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

7891011

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

12

L1L21

56789101112

234

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenOrange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

1

56789101112

234

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

252627282930313233343536

NOT USED

NOT USEDNOT USED

131415161718192021222324

L1-6L2-6L1-7

L2-7L1-8L2-8

L2-9L1-9

L2-10L1-10

L1-11L2-11

NOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USED

L1-0

L2-0

L1-1L2-1L1-2L2-2

L2-3L1-3

L2-4L1-4

L1-5L2-5

LOADL1L2

L1-6

L2-6

L1-7L2-7L1-8L2-8

L2-9L1-9

L2-10L1-10

L1-11L2-11

L1-0L2-0L1-1L2-1L1-2L2-2

L2-3L1-3

L2-4L1-4

L1-5L2-5

CABLE”A”

CABLE”B”NOT USED

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IM16I RTB. Each cable can be either0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion

� The input delay times for the 1771-IM module versus the 1756-IM16I module are as follows: 1771-ID01 1756-IM16I w/ 1492-C005005XLa) Off-to-On Delay 20ms (+/-10ms) 10ms max (plus selectable filter)b) On-to-Off Delay 20ms (+/-10ms) 8ms max (plus selectable filter)

� The 1771-ID01module had a jumper selection of N.O. and N.C. outputs. The 1756-IM16I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionalityof the 1771-ID01 jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output isrequired, change the jumper from pins 1-2 to pins 3-4.

� Refer to your 1771-ID01 and 1756-IM16I Installation Manual wiring schematics and diagrams for more details. Ensure1756 output module ratings are not exceeded. [Reference Doc: 41171-015 (Version 00)]

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 29

Page 30: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-ID16 to 1756-IA16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations� The input delay times for the 1771-ID16 module versus 1756-IA16I module are as follows:

1771-ID16 1756-IA16Ia) Off-to-On Delay 0.57ms 10ms max (plus selectable filter)b) On-to-Off Delay 9ms or 18ms (selectable) 8ms max (plus selectable filter)� The 1771-ID16 module is rated 74V to 138V AC and105V to 138V DC. The 1756-IA16I is rated 79V to 132V AC. If the input source voltage is DC use a 1756-IH16I with this conversion module.� Refer to your 1771-ID16 and 1756-IA16I Installation Manual wiring schematics and diagrams for more details.

[Reference Doc: 41170-931 (Version 02)]

1771-WN Swing ArmFrom 1771-ID16

1 2

436587

121114131615181722212423262528273231343336353837910192029303940

Input 14

Input 16

Input 15

Input 17

Input 4

Input 6

Input 5

Input 7

Input 0

Input 2

Input 1

Input 3

Input 10

Input 12

Input 11

Input 13

Not usedNot usedNot usedNot usedNot usedNot usedNot usedNot used

12345678910111213

151617181920

14

21222324252627282930313233

353637

34

IN-0

21

IN-1

43

IN-2

65

IN-3

87

IN-4

109

IN-5

1211

IN-6

1413

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenIN-7

1615

IN-8

1817

IN-9

2019

IN-10

2221

IN-11

2423

IN-12

2625

IN-13

2827

IN-14

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/White

Green/Black/White

Orange/Black/White

Blue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueIN-15

3231

L2-0

L2-1

L2-2

L2-3

L2-4

L2-5

L2-6

L2-7

L2-8

L2-9

L2-10

L2-11

L2-12

L2-13

L2-14

L2-15

L2

L1

L2-0

L2-1

L2-2

L2-3

L2-4

L2-5

L2-6

L2-7

L2-10

L2-11

L2-12

L2-13

L2-14

L2-15

L2-16

L2-17

1756-IA16I

Conversion Module1492-CM1771-LD004

Cable1492-CONCAB005Y�

IMPORTANT

30 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 31: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-ID16 to 1756-IH16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations� The input delay times for the 1771-ID16 module versus 1756-IH16I module are as follows:

1771-ID16 1756-IH16Ia) Off-to-On Delay 0.57ms 2ms max (plus selectable filter)b) On-to-Off Delay 9ms or 18ms (selectable) 6ms max (plus selectable filter)� The 1771-ID16 module is rated 74V to 138V AC and105V to 138V DC. The 1756-IH16I is rated 90V to 146V DC. If the input source voltage is AC use a 1756-IA16I with this conversion module.� Refer to your 1771-ID16 and 1756-IH16I Installation Manual wiring schematics and diagrams for more details.

[Reference Doc: 41170-932 (Version 02)]

1771-WN Swing ArmFrom 1771-ID16

IN-0

IN-1

IN-2

IN-3

IN-4

IN-5

IN-6

IN-7

IN-8

IN-9

IN-10

IN-11

IN-12

IN-13

IN-14

IN-15

GND-0

GND-1

GND-2

GND-3

GND-4

GND-5

GND-6

GND-7

GND-8

GND-9

GND-10

GND-11

GND-12

GND-13

GND-14

GND-15

1 2

436587

121114131615181722212423262528273231343336353837910192029303940

Input 14

Input 16

Input 15

Input 17

Input 4

Input 6

Input 5

Input 7

Input 0

Input 2

Input 1

Input 3

Input 10

Input 12

Input 11

Input 13

Not usedNot usedNot usedNot usedNot usedNot usedNot usedNot used

12345678910111213

151617181920

14

21222324252627282930313233

353637

34

2143658710912111413

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

16151817201922212423262528273029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/White

Green/Black/White

Orange/Black/White

Blue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

3231

L2-0

L2-1

L2-2

L2-3

L2-4

L2-5

L2-6

L2-7

L2-10

L2-11

L2-12

L2-13

L2-14

L2-15

L2-16

L2-17

+

-

1756-IH16I

Conversion Module1492-CM1771-LD004

Cable1492-CONCAB005Y�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 31

Page 32: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IG to 1756-IG16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1771-WC Swing ArmFrom 1771-IG

1771-WC Swing ArmFrom 1771-IG

Conversion Module1492-CM1771-LA003

Conversion Module1492-CM1771-LA003

Cable1492-C005005XS� 1756-IG16

Conversion Module Installation and Application Considerations � This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IG16 RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion.

� The input delay times for the 1771-IG module versus the 1756-IG16 module are as follows: 1771-IG 1756-IG16 w/ 1492-C005005XS a) Off-to-On Delay 1ms (+/-10ms) 270ms max (plus selectable filter) b) On-to-Off Delay 1ms (+/-10ms) 390ms max (plus selectable filter)

� The 1771-IG module is rated 5V DC TTL INPUT MODULE. The 1756-IG16 module is rated 5V DC TTL INPUT MODULE only.

� Refer to your 1771-IG and 1756-IG16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. [Reference Doc: 41171-027 (Version 00)]

InputDevice

1325242322211918171612

SH

Input 0 + DC 10

IN-0IN-1

1

IN-2

234567

98

Red/White

Green/Black/White

Black/White/Red

White/Black/Red

Orange/Green

Red/Black/White

Orange/Red

Blue/Red

+ -

A

34567B

012

Common

Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7

3456789101112141520

IN-3IN-4IN-5IN-6IN-7

+ DC -0

- DC -020

IN-8IN-9IN-10IN-11IN-12IN-13IN-14IN-15

+ DC -1

- DC -1

1325242322211918171612

SH

Red/White

Green/Black/White

Black/White/Red

White/Black/Red

Orange/Green

Red/Black/White

Orange/Red

Blue/Red

A

34567B

012

3456789101112141520

Input 0 + DC

Common

Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7

111213141516171819

Black/Red

White/Red

Black/Red

White/Red

CABLE”B”

CABLE”A”+

- 5V DCSUPPLY

InputDevice

+ -

+

- 5V DCSUPPLY

IMPORTANT

32 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 33: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IGD to 1756-IG16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1771-WH, WHF, WHFB Swing ArmFrom 1771-IGD

Conversion Module1492-CM1771-LD006

Cable1492-CONCAB005X� 1756-IG16

� This Bul. 1492 cable consists of a cable wired to one 1756-IG16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-IGD module output current limits versus 1756-IG16 limits are as follows: 1771-IGD 1756-IG16 w/ 1492-CONCAB005Xa) Current/Point 122mA 110mAb) Current/Module 500mA 110mA

� The 1771-IGD is rated 5V DC. The 1756-IG16 is rated 4.5V to 5.5V DC.

� Refer to your 1771-IGD and 1756-IG16 Installation Manual wiring schematics and diagrams for more details. Ensure1756 output module ratings are not exceeded. [Reference Doc: 41171-004 (Version 00)]

Conversion Module Installation and Application Considerations

10DC-0+

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenDC-1+

20

9RTN OUT-0

19RTN OUT-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Input 00

+ dc

- dc

B

CD

DC InputDevice

+

-

+-

+ dc

+ dc

+ dc

24

212223

25

Input 01Input 02Input 03Input 04Input 05Input 06Input 07Input 08Input 09Input 10Input 11Input 12Input 13Input 14Input 15

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 33

Page 34: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IH to 1756-IC16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IC16 RTB. Recommended cablelengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths.

� The 1771-IH module is rated 24V - 48V DC. The 1756-IC16 module is rated 30V - 60V DC.

� Refer to your 1771-IH and 1756-IC16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-997 (Version 00)]

� The input delay times for the 1771-IH module versus the 1756-IC16 module are as follows: 1771-IH 1756-IC16 w/ 1492-C005005XEa) Off-to-On Delay 15ms (+/-7ms) 1ms max (plus selectable filter)b) On-to-Off Delay 15ms (+/-7ms) 4ms max (plus selectable filter)

Conversion Module Installation and Application Considerations

B

34567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

1

19

345678910111213

15161718

20

14

2

24

212223

25

+

-

10GND-0

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

GND-120

9GND-0

19GND-1

CABLE “A”

CABLE “B”

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7GND-0

B

34567

A012

1

19

345678910111213

15161718

20

14

2

24

212223

25

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7GND-1

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

+

-

1771-WA Swing ArmFrom 1771-IH

1771-WA Swing ArmFrom 1771-IH

1756-IC16 Conversion Module1492-CM1771-LD007

Conversion Module1492-CM1771-LD007

Cable1492-C005005XE�

IMPORTANT

34 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 35: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IM to 1756-IM16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IM16I RTB. Recommended cablelengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths.

� The 1771-IM module is rated 220V to 240V AC. The 1756-IM16I module is rated 159 - 265V AC only.

� Refer to your 1771-IM and 1756-IM16I Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-990 (Version 00)]

� The input delay times for the 1771-IM module versus the 1756-IM16I module are as follows: 1771-IM 1756-IM16I w/ 1492-C005005XHa) Off-to-On Delay 20ms (+/-6ms) 10ms max (plus selectable filter)b) On-to-Off Delay 20ms (+/-6ms) 8ms max (plus selectable filter)

Conversion Module Installation and Application Considerations

1756-IM16I Conversion Module1492-CM1771-LD007

Conversion Module1492-CM1771-LD007

Cable1492-C005005XH�

B

34567

A

1771-WA Swing ArmFrom 1771-IM

012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

1

19

345678910111213

15161718

20

14

2

24

212223

25

L1

L2

2L2-0

IN-01

IN-13

IN-25

IN-37

IN-49

IN-511

IN-613

IN-715

IN-817

IN-919

IN-1021

IN-1123

IN-1225

IN-1327

IN-1429

IN-1531

L2-118

4L2-0

20L2-1

CABLE “A”

CABLE “B”

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7L2

B

34567

A

1771-WA Swing ArmFrom 1771-IM

012

1

19

345678910111213

15161718

20

14

2

24

212223

25

L1

L2

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7L2

Black

WhiteRed

GreenOrange

BlueWhite/Black

Red/BlackGreen/Black

Orange/Black

L2-0L2-0

6810121416

L2-1

L2-1L2-1L2-1L2-1

L2-1

22

26283032

24

L2-0L2-0L2-0L2-0

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 35

Page 36: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IMD to 1756-IM16I

1756-IM16I

1771-WH Swing ArmFrom 1771-IMD

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module1492-CM1771-LD002

Cable1492-CONCAB005Y�

Conversion Module Installation and Application Considerations� The input delay times for the 1771-IMD module versus 1756-IM16I module are as follows: 1771-IMD 1756-IM16Ia) Off-to-On Delay 15ms (+/-8ms) 10ms (plus selectable filter)b) On-to-Off Delay 172ms (+/-56ms) 8ms (plus selectable filter)� The 1771-IMD module is rated 184V AC to 250V AC and 166V-230V DC. The 1756-IM16I module is rated 159V to 265V AC. A1756 input module with an equivalent DC voltage range to convert the 1771-IMD is not available.� Refer to your 1771-IMD and 1756-IM16I Installation Manual wiring schematics and diagrams for more details.

[Reference Doc: 41170-928 (Version 02)]

A

00

01

02

03

04

05

06

07

E

10

11

12

13

14

15

16

17

Input 14

Input 16

Input 15

Input 17

Input 04

Input 06

Input 05

Input 07

Input 00

Input 02

Input 01

Input 03

Input 10

Input 12

Input 11

Input 13

Terminal A

Terminal E

BCD

Terminal BTerminal CTerminal D

12345678910111213

151617181920

14

21222324252627282930313233

353637

34

IN-0

21

IN-1

43

IN-2

65

IN-3

87

IN-4

109

IN-5

1211

IN-6

1413

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenIN-7

1615

IN-8

1817

IN-9

2019

IN-10

2221

IN-11

2423

IN-12

2625

IN-13

2827

IN-14

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueIN-15

3231

L2-0

L2-1

L2-2

L2-3

L2-4

L2-5

L2-6

L2-7

L2-8

L2-9

L2-10

L2-11

L2-12

L2-13

L2-14

L2-15

L1

L2

IMPORTANT

36 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 37: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IN to 1756-IN16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IN16 RTB. Recommended cablelengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths.

� The 1771-IN module is rated 24V AC. The 1756-IN16 module is rated 24V AC only.

� Refer to your 1771-IN and 1756-IN16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-998 (Version 00)]

� The input delay times for the 1771-IN module versus the 1756-IN16 module are as follows: 1771-IN 1756-IN16 w/ 1492-C005005XEa) Off-to-On Delay 18ms (+/-10ms) 10ms max (plus selectable filter)b) On-to-Off Delay 18ms (+/-10ms) 10ms max (plus selectable filter)

Conversion Module Installation and Application Considerations

B

34567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

1

19

345678910111213

15161718

20

14

2

24

212223

25

+

-

1756-IN16

10L2-0

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

L2-120

9L2-0

19L2-1

CABLE “A”

CABLE “B”

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7GND-1

B

34567

A012

1

19

345678910111213

15161718

20

14

2

24

212223

25

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7L2

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

+

-

1771-WA Swing ArmFrom 1771-IN

1771-WA Swing ArmFrom 1771-IN

Conversion Module1492-CM1771-LD007

Conversion Module1492-CM1771-LD007

Cable1492-C005005XE�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 37

Page 38: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IND to 1756-IN16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

� This Bul. 1492 cable consists of a cable wired to one 1756-IN16 RTB. Recommended cable lengths of0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

Conversion Module Installation and Application Considerations

1756-IN16

10L2-0

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenL2-1

20

9L2-0

19L2-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Input 14

Input 16Input 15

Input 17

Input 04

Input 06Input 05

Input 07

Input 00

Input 02Input 01

Input 03

Input 10

Input 12Input 11

Input 13

Terminal A

Terminal E

BCD

Terminal BTerminal CTerminal D

� The 1771-IND module is rated 24V AC or DC. The 1756-IN16 module is rated 10V to 30V AC.

� Refer to your 1771-IND and 1756-IN16 Installation Manual wiring schematics and diagrams for more details.

[Reference Doc: 41170-002 (Version 00)]

1771-WH Swing ArmFrom 1771-IND

� The input delay times for the 1771-IND module versus the 1756-IN16 module are as follows: 1771-IND 1756-IN16 w/ 1492-CONCAB005Xa) Off-to-On Delay 35ms (+/-10ms) @24V AC 10ms max (plus selectable filter)b) On-to-Off Delay 45ms (+/-15ms) 10ms max (plus selectable filter)

L1

L2

24

212223

25

Conversion Module1492-CM1771-LD001

Cable1492-CONCAB005X�

IMPORTANT

38 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 39: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IND1 to 1756-IN16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

� This Bul. 1492 cable consists of a cable wired to one 1756-IN16 RTB. Recommended cable lengths of0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

Conversion Module Installation and Application Considerations

1756-IN16

10L2-0

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenL2-1

20

9L2-0

19L2-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Input 14

Input 16Input 15

Input 17

Input 04

Input 06Input 05

Input 07

Input 00

Input 02Input 01

Input 03

Input 10

Input 12Input 11

Input 13

Terminal A

Terminal E

BCD

Terminal BTerminal CTerminal D

� The 1771-IND1 module is rated 48V AC. The 1756-IN16 module is rated 10V to 30V AC.

� Refer to your 1771-IND1 and 1756-IN16 Installation Manual wiring schematics and diagrams for more details.

[Reference Doc: 41170-003 (Version 00)]

1771-WH Swing ArmFrom 1771-IND1

� The input delay times for the 1771-IND1 module versus the 1756-IN16 module are as follows: 1771-IND1 1756-IN16 w/ 1492-CONCAB005Xa) Off-to-On Delay 25ms (+/-5ms) @48V AC 10ms max (plus selectable filter)b) On-to-Off Delay 35ms (+/-10ms) 10ms max (plus selectable filter)

L1

L2

24

212223

25

Conversion Module1492-CM1771-LD001

Cable1492-CONCAB005X�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 39

Page 40: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IQ to 1756-IB16I— Sinking

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IB16I RTB. Recommended cablelengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths.

� The 1771-IQ module is rated 5V to 30V DC. The 1756-IB16I module is rated 10V to 30V DC only.

� Refer to your 1771-IQ and 1756-IB16I Installation Manual wiring schematics and diagrams for more details.

� For Sourcing applications use 1492-CM1771-LD014. [Reference Doc: 41170-992 (Version 00)]

� The input delay times for the 1771-IQ module versus the 1756-IB16I module are as follows: 1771-IQ 1756-IB16I w/ 1492-C005005XKa) Off-to-On Delay 12ms (+/-14ms) 1ms max (plus selectable filter)b) On-to-Off Delay 12ms (+/-7ms) 4ms max (plus selectable filter)

Conversion Module Installation and Application Considerations

1756-IB16I Conversion Module1492-CM1771-LD007

Conversion Module1492-CM1771-LD007

Cable1492-C005005XK�

1771-WA Swing ArmFrom 1771-IQ

1771-WA Swing ArmFrom 1771-IQ

B

34567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

1

19

345678910111213

15161718

20

14

2

24

212223

25

+

_

IN-01

IN-13

IN-25

IN-37

IN-49

IN-511

IN-613

IN-715

IN-817

IN-919

IN-1021

IN-1123

IN-1225

IN-1327

IN-1429

IN-153118

2

L2-0

20

CABLE “A”

CABLE “B”

Not usedIN 0

L2 - 0

B

34567

A012

1

19

345678910111213

15161718

20

14

2

24

212223

25

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7L2 - 1

Black

WhiteRed

GreenOrange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

IN 1IN 2IN 3IN 4IN 5IN 6IN 7

222426283032

+

_

6810121416

4

L2-0L2-0L2-0L2-0L2-0L2-0

L2-1L2-1L2-1L2-1L2-1L2-1L2-1L2-1

L2-0

IMPORTANT

40 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 41: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IQ to 1756-IB16I— Sourcing

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1756-IB16I

Conversion Module1492-CM1771-LD0014

Conversion Module1492-CM1771-LD0014

Cable1492-C005005XJ�

1771-WA Swing ArmFrom 1771-IQ

1771-WA Swing ArmFrom 1771-IQ

CABLE”A”

CABLE”B”

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IB16I RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion.

� The input delay times for the 1771-IQ module versus the 1756-IB16 module are as follows: 1771-IQ 1756-IB16I w/1492-C005005XJa) Off-to-On Delay 12ms (+/-14ms) 1ms max (plus selectable filter)b) On-to-Off Delay 12ms (+/-14ms) 4ms max (plus selectable filter)

� The 1771-IQ module is rated 5V to 30V DC. The 1756-IB16I module is rated 10V to 30V SOURCING DC only.

� Refer to your 1771-IQ and 1756-IB16I Installation Manual wiring schematics and diagrams for more details.

� For Sinking applications use 1492-CM1771-LD007. [Reference Doc: 41170-991 (Version 00)]

B

3

4567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

DC+

GND-02

GND-14

GND-26

GND-38

GND-4

1

GND-5

3

GND-6

5

GND-7

7911131510121416

GND-15

NOT-USED

LOAD

-

+

1

19

345678910111213

15161718

20

14

2

24

212223

25

DC -

GND 00GND 01GND 02GND 03

GND 04GND 05GND 06GND 07

B

3

4567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

DC +

GND-818

OUT-920

OUT-1022

OUT-1124

GND-12

17

GND-13

19

GND-14

21

GND-15

232527293126283032

LOAD

-

+

1

19

345678910111213

15161718

20

14

2

24

212223

25

DC -

GND 08GND 09

GND -10GND -11

GND -12GND -13GND -14GND -15

IN - 0IN - 1IN - 2IN - 3IN - 4IN - 5IN - 6IN - 7

33

34

35NOT-USED

-

36NOT-USED

IN - 8IN - 9IN - 10IN - 11IN - 12IN - 13IN - 14IN - 15

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41

Page 42: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IQ16 to 1756-IB16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these consid-erations before installation.

Conversion Module Installation and Application Considerations� The input delay times for the 1771-IQ16 module versus 1756-IB16I module are as follows:

1771-IQ16 1756-IB16Ia) Off-to-On Delay 0.57ms 1ms max (plus selectable filter)b) On-to-Off Delay 0.57ms 4ms max (plus selectable filter)� Both the 1771-IQ16 and 1756-IB16I allow operation with sourcing inputs. Refer to installation Instructions for details.� Refer to your 1771-IQ16 and 1756-IH16I Installation Manual wiring schematics and diagrams for more details.

[Reference Doc: 41170-933 (Version 02)]

1771-WN Swing ArmFrom 1771-IQ16

IN-0

IN-1

IN-2

IN-3

IN-4

IN-5

IN-6

IN-7

IN-8

IN-9

IN-10

IN-11

IN-12

IN-13

IN-14

IN-15

Gnd-0

Gnd-1

Gnd-2

Gnd-3

Gnd-4

Gnd-5

Gnd-6

Gnd-7

Gnd-8

Gnd-9

Gnd-10

Gnd-11

Gnd-12

Gnd-13

Gnd-14

Gnd-15

Gnd-0

Gnd-1

Gnd-2

Gnd-3

Gnd-4

Gnd-5

Gnd-6

Gnd-7

Gnd-10

Gnd-11

Gnd-12

Gnd-13

Gnd-14

Gnd-15

Gnd-16

Gnd-17

1 2

436587

121114131615181722212423262528273231343336353837910192029303940

Input 14

Input 16

Input 15

Input 17

Input 4

Input 6

Input 5

Input 7

Input 0

Sinking Input Example

SourcingInputExample

Input 2

Input 1

Input 3

Input 10

Input 12

Input 11

Input 13

Not usedNot usedNot usedNot usedNot usedNot usedNot usedNot used

12345678910111213

151617181920

14

21222324252627282930313233

353637

34

1756-IB16I

2143658710912111413

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

16151817201922212423262528273029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/White

Green/Black/White

Orange/Black/White

Blue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

3231

+

-

+

-

Conversion Module1492-CM1771-LD004

Cable1492-CONCAB005Y�

IMPORTANT

42 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 43: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IT to 1756-IB16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IB16 RTB. Recommended cablelengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths.

� The 1771-IT module is rated 24V DC. The 1756-IB16 module is rated 24V DC only.

� Refer to your 1771-IT and 1756-IB16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-999 (Version 00)]

� The input delay times for the 1771-IT module versus the 1756-IB16 module are as follows: 1771-IT 1756-IB16 w/ 1492-C005005XEa) Off-to-On Delay 0.6ms (+/-0.2ms) 1ms max (plus selectable filter)b) On-to-Off Delay 0.6ms (+/-0.2ms) 2ms max (plus selectable filter)

Conversion Module Installation and Application Considerations

B

34567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

1

19

345678910111213

15161718

20

14

2

24

212223

25

+

-

10GND-0

IN-01

IN-12

IN-23

IN-34

IN-45

IN-56

IN-67

IN-78

IN-811

IN-912

IN-1013

IN-1114

IN-1215

IN-1316

IN-1417

IN-1518

GND-120

9GND-0

19GND-1

CABLE “A”

CABLE “B”

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7GND-1

B

34567

A012

1

19

345678910111213

15161718

20

14

2

24

212223

25

Not used

Input 0Input 1

Input 2Input 3Input 4Input 5

Input 6

Input 7GND-1

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/Black

+

-

1771-WA Swing ArmFrom 1771-IT

1771-WA Swing ArmFrom 1771-IT

1756-IB16 Conversion Module1492-CM1771-LD007

Conversion Module1492-CM1771-LD007

Cable1492-C005005XE�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 43

Page 44: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IV to 1756-IV16There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1771-WA Swing ArmFrom 1771-IV

1771-WA Swing ArmFrom 1771-IV

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IV16 RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion.

� The input delay times for the 1771-IV module versus the 1756-IV16 module are as follows: 1771-IV 1756-IV16 w/1492-C005005XGa) Off-to-On Delay 15ms (+/-7ms) 1ms max (plus selectable filter)b) On-to-Off Delay 15ms (+/-7ms) 2ms max (plus selectable filter)

� The 1771-IV module is rated 12 To 24V DC. The 1756-IV16 module is rated 10V To 30V DC only.

� Refer to your 1771-IV and 1756-IV16 Installation Manual wiring schematics and diagrams for more details.

[Reference Doc: 41170-989 (Version 00)]

1756-IV16

Conversion Module1492-CM1771-LD014

Conversion Module1492-CM1771-LD014

Cable1492-C005005XG�

B

3

4567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

+DC-0

+DC-0

IN-01

IN-12

IN-23

IN-34

IN-4

9

IN-5

10

IN-6IN-7

5678

LOAD

-

+

1

19

345678910111213

15161718

20

14

2

24

212223

25

-DC-0

B

3

4567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

+DC-1

IN-811

IN-912

IN-1013

IN-1114

IN-12

19

IN-13

20

IN-14IN-15

15161718

LOAD

-

+

1

19

345678910111213

15161718

20

14

2

24

212223

25

-DC-1

+DC-0

+DC-1

INPUT 03INPUT 02INPUT 01INPUT 00

INPUT 07INPUT 06INPUT 05INPUT 04

+DC-1

INPUT 11INPUT 10INPUT 09INPUT 08

INPUT 15INPUT 14INPUT 13INPUT 12

Cable A

Cable B

IMPORTANT

44 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 45: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

1771-IVN to 1756-IV32There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

18DC-0 (+)

IN-01

IN-1619

IN-12

IN-1720

IN-23

IN-1821

IN-34

IN-1922

IN-45

IN-2023

IN-56

IN-2124

IN-67

IN-2225

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

IN-78

12345647859

24

10611

25

12713

26

8

9291030

15

27

1617

28

18

2

1920

14

2122

13

2324

14

25

33

26

15

27

34

28

16

29

35

30

17

31

36

32

18

33

37

22

35

38

3637

34

DC-1 (+)36

IN-2326

IN-89

IN-2427

IN-910

IN-2528

IN-1011

IN-2629

IN-1112

IN-2730

IN-1213

IN-2831

IN-1314

IN-2932

IN-1415

IN-3033

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/White

Green/Black/White

Orange/Black/White

Blue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

IN-1516

IN-313417

DC-0 (+)White/Red/Blue DC-1 (+)

35

Input 01Input 01Input 02Input 02Input 03Input 03Input 04Input 04Input 05Input 05Input 06Input 06Input 07Input 07

Input 10

Input 11

Input 10

Input 12Input 13Input 13Input 14Input 14Input 15Input 15Input 16Input 16Input 17Input 17

Input 00

19392040111

23

10-30V dc (0)

3Input 00

Input 11

Input 12

31

1221

32

+-

10-30V dc (2)

10-30V dc (0)10-30V dc (1)10-30V dc (1)

10-30V dc (3)10-30V dc (2)

10-30V dc (3)

Conversion Module Installation and Application Considerations� The input delay times for the 1771-IVN module versus 1756-IV32 module are as follows: 1771-IVN 1756-IV32a) Off-to-On Delay 6ms (+/-2ms) 1ms (plus selectable filter)b) On-to-Off Delay 6ms (+/-2ms) 2ms (plus selectable filter)� The 1771-IVN has 4 groups (allowing 4 seperate power supplies) and the 1756-IV32 has 2 groups.

This module/cable combination ties Groups 0 & 1 from the 1771-IVN to Group 0 on the 1756-IV32 and it ties Groups 2 & 3 from the 1771-IVN to Group 1 on the 1756-IV32.Field wiring modification must be made to accommodate this if multiple supplies were used. If 4 supplies were used, 2 must be removed.

� Refer to your 1771-IVN and 1756-IV32 Installation Manual wiring schematics and diagrams for more details.[Reference Doc: 41170-934 (Version 02)]

1771-WN Swing ArmFrom 1771-IVN

Conversion Module1492-CM1771-LD005

Cable1492-CONCAB005Z� 1756-IV32

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 45

Page 46: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Inputs

Notes:

46 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 47: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OA to 1756-OA8E

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module1492-CM1771-LD014

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-OA8E RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OA module output current limits versus 1756-OA8E limits are as follows: 1771-OA 1756-OA8E w/ 1492-CONCAB005Ua) Current/Point 1.5A 2Ab) Current/Module 6A 4A @ 60°Cc) Surge Current/Pt 4A for 8.3ms 20A for 43 ms

� The 1771-OA has eight (8) 2A, 250V fuses - 1 per output. The 1756-OA8E is electronically fused per point. Refer to the 1756-OA8E Installation Manual for details on electronic fusing.

� Refer to your 1771-OA and 1756-OA8E Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41170-943 (Version 01)]

Cable1492-CONCAB005U�

B

3

4567

A

1771-WA Swing ArmFrom 1771-OA

012

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

L1

1756-OA8E

2

L2-0OUT-0

3

OUT-15

OUT-27

OUT-39

OUT-4

4

OUT-5

6

OUT-6

8

OUT-7

101214161811131517

L2-119

1Not Used

20L1-1

LOAD

L2

L1

L1-0L1-0L1-0L1-0L1-1L1-1L1-1L1-1

1

19

345678910111213

15161718

20

14

2

24

212223

25

L2

Output 00Output 01Output 02Output 03

Output 04Output 05Output 06Output 07

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 47

Page 48: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OAD to 1756-OA16There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1771-WH, WHF, WHFB Swing ArmFrom 1771-OAD

Conversion Module1492-CM1771-LD006

Cable1492-CONCAB005X� 1756-OA16

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-OA16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OAD module output current limits versus 1756-OA16 limits are as follows: 1771-OAD 1756-OA16 w/ 1492-CONCAB005Xa) Current/Point 2A 0.5Ab) Current/Module 8A 4Ac) Surge Current/point 25A for 100ms 5A for 43ms

� The L2 terminal (Terminal E) on the 1771-OAD module was an optional connection, but it is required for the 1756-OA16. This connection must be added if it was not connected.

� The 1771-OAD is rated 10V to 138V AC. The 1756-OA16 is rated 74V to 256V AC.

� Refer to your 1771-OAD and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41170-935 (Version 01)]

10L1-0

OUT-01

OUT-12

OUT-23

OUT-34

OUT-45

OUT-56

OUT-67

OUT-78

OUT-811

OUT-912

OUT-1013

OUT-1114

OUT-1215

OUT-1316

OUT-1417

OUT-1518

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenL1-1

20

9L2-0

19L2-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Output 14

Output 16Output 15

Output 17

Output 04

Output 06

OutputDevice

Output 05

Output 07

Output 00

Output 02Output 01

Output 03

Output 10

Output 12Output 11

Output 13

L1

L2

BCD

L1L1L1

L1

L2

24

212223

25

IMPORTANT

48 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 49: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OAN to 1756-OA16

1771-WN Swing ArmFrom 1771-OAN

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1756-OA16

1756-OA16

Conversion Module1492-CM1771-LD013

Cable1492-CONCAB005S3�

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to two 1756-OA16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OAN module output current limits versus 1756-OA16 limits are as follows: 1771-OAN 1756-OA16 w/ 1492-CONCAB005S3a) Current/Point 1A 0.5Ab) Current/Module 8A (32 pts) 2A (16 pts)c) Surge Current/Point 10A for 25ms 5A for 43ms

� The 1771-OAN has 4 groups (allowing 4 separate power supplies). This module/cable combination ties all 4 groups from the 1771-OAN together. Field wiring modification must be made to accommodate this if mulitple supplies were used. If more than 1 supply was used, all but 1 of the power supplies must be removed.

� The 1771-OAN did not allow connections for L2, however the 1756-OA16 requires an L2 connection for proper operation. The 1771-OAN did not use terminals 10, 20, 30, 40. These terminals have been reassigned for an L2 connection in this application. The installer must rewire L2 to one of these terminals.

� Refer to your 1771-OAN and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded.

� This configuration uses two (2) 1756-OA16 output modules to replace a single 1771-OAN output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility. [Reference Doc: 41170-942 (Version 02)]

10 L1-0L2-01 OUT-02 OUT-13 OUT-24

OUT-12

5

OUT-13

6

OUT-14

7

OUT-15

81112131415161718

BlackWhiteRedGreenOrange

BlueWhite/Black

Red/BlackGreen/Black

Orange/BlackBlue/BlackBlack/WhiteRed/WhiteGreen/WhiteBlue/WhiteBlack/RedWhite/Red

12345

78910

18

111213

151617

14

L1-119

9

OUT-3

20

L2-1

OUT-4OUT-5OUT-6OUT-7OUT-8OUT-9OUT-10OUT-11

10

123456781112131415161718

19

9

20

20 Red/Green21 Orange/Green

22 Black/White/Red

24 Red/Black/White

25 Green/Black/White

26 Orange/Black/White27 Blue/Black/White28 Black/Red/Green29 White/Red/Green

30 Red/Black/Green

31 Green/Black/Orange32 Orange/Black/Green33 Blue/White/Orange

34 Black/White/Orange

35 White/Red/Orange36

White/Red/Blue37

A EL

UD

OM

B EL

UD

OM

30

202

40

43

65

87

129

34

13

1

1615

1817

22

19

2423

2625

2827

3229

11

33

10L2L2

L2L2

Output 00Output 01Output 02Output 03Output 04Output 05Output 06Output 07Output 10Output 11

Output 13

Output 15

Output 12

Output 17

L1

35

31

14

L1

21L1

Output 14

Output 16

38

3637

39

L1

Output 00Output 01Output 02Output 03Output 04Output 05Output 06Output 07Output 10Output 11

Output 13

Output 15

Output 12

Output 17

Output 14

Output 16

Orange/Red

6

L1-0L2-0OUT-0OUT-1OUT-2

OUT-12OUT-13OUT-14OUT-15L1-1

OUT-3

L2-1

OUT-4OUT-5OUT-6OUT-7OUT-8OUT-9OUT-10OUT-11

23 White/Black/Red

Orange/White/Blue

L1

L2

OutputDevice

19 Blue/Red

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 49

Page 50: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OB to 1756-OB16D

1756-OB16D

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

1771-WA Swing ArmFrom 1771-OB

1771-WA Swing ArmFrom 1771-OB Conversion Module

1492-CM1771-LD014

Conversion Module1492-CM1771-LD014 Cable

1492-C005005XF�

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OB16D RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion.

� The 1771-OB module output current limits versus 1756-OB16D limits are as follows: 1771-OB 1756-OB16D w/ 1492-C005005XFa) Current/Point 1.5A 2Ab) Current/Module 6A 4A @ 60°Cc) Surge Current/Point 4A for 8.3ms 4A for 10ms

� The 1771-OB has eight (8) 2A, 250V fuses - 1 per output. The 1756-OB16D is a DIAGNOSTIC MODULE. Refer to the 1756-OB16D Installation Manual for details on diagnostics.

� Refer to your 1771-OB and 1756-OB16D Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41170-988 (Version 00)]

B

3

4567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

L1GND-0 OUT-0

1

OUT-13

OUT-25

OUT-37

OUT-4

2

OUT-5

4

OUT-6

6

OUT-7

8101214

9111315

GND-016

16

LOAD

-

+

+DC-0+DC-0+DC-0+DC-0+DC-0+DC-0+DC-0

1

19

345678910111213

15161718

20

14

2

24

212223

25

L2

Output 00Output 01Output 02Output 03

Output 04Output 05Output 06Output 07

B

3

4567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

L1

OUT-817

OUT-919

OUT-1021

OUT-1123

OUT-12

18

OUT-13

20

OUT-14

22

OUT-15

2426283025272931

GND-132

32

LOAD

-

+

+DC-1+DC-1+DC-1+DC-1+DC-1+DC-1+DC-1

GND-1

1

19

345678910111213

15161718

20

14

2

24

212223

25

L2

Output 00Output 01Output 02Output 03

Output 04Output 05Output 06Output 07

GND-1

CABLE”A”

CABLE”B”

NOT USED

34

NOT USED33

NOT USED35

ONT USED36

IMPORTANT

50 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 51: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OBD to 1756-OB16E

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

1771-WH, WHF, WHFB Swing ArmFrom 1771-OBD

Conversion Module1492-CM1771-LD006

Cable1492-CONCAB005X� 1756-OB16E

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-OA16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OBD module output current limits versus 1756-OB16E limits are as follows: 1771-OBD 1756-OB16E w/ 1492-CONCAB005X

a) Current/Point 2A 1Ab) Current/Module 8A 4Ac) Surge Current/point 4A for 10ms 2A for 10ms

� The 1771-OBD has a single 10A, 250V rectifier fuse (1/4 x 1 1/4 inch). The 1756-OB16E is electronically fused pergroup. Refer to the 1756-OB16E Installation Manual for details on electronic fusing.

� The 1771-OBD is rated 10V to 60V DC. The 1756-OB16E is rated 10V to 31.2V DC. If the load source voltage is greater than 30V DC, then use the 1756-OC8 with the 1492-CM1771-LD008F conversion module.

� Refer to your 1771-OBD and 1756-OB16E Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41170-936 (Version 01)]

+

+

-

-

10DC-0+

OUT-01

OUT-12

OUT-23

OUT-34

OUT-45

OUT-56

OUT-67

OUT-78

OUT-811

OUT-912

OUT-1013

OUT-1114

OUT-1215

OUT-1316

OUT-1417

OUT-1518

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenDC-1+

20

9RTN OUT-0

19RTN OUT-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Output 14

Output 16Output 15

Output 17

Output 04

Output 06

dc OutputDevice

Output 05

Output 07

Output 00

Output 02Output 01

Output 03

Output 10

Output 12Output 11

Output 13

+ dc

L2

BCD

+ dc+ dc+ dc

24

212223

25

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 51

Page 52: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OBD to 1756-OC8

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to two 1756-OC8 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OBD module output current limits versus 1756-OC8 limits are as follows: 1771-OBD 1756-OC8 w/ 1492-CONCAB005S1a) Current/Point 2A 2Ab) Current /Module 8A 8Ac) Surge Current /Point 4A for 10ms 4A for 10ms

� The 1771-OBD has a single 10A, 250V rectifier fuse (1/4 x 1 1/4 inch ). The 1756-OC8 is NOT fused ,as such a2AG fuse clip and 10A fuse is provided on the 1492-CM1771-LD008F conversion module.

� The 1771-OBD is rated 10V to 60V DC. The 1756-OC8 is rated 30V to 60V DC. If the load source voltages is lessthan 30V DC, then use 1756-OB16E with the 1492-CM1771-LD006 conversion module.

� This configuration uses two(2) 1756-OC8 output modules to replace a single 1771-OBD output module. This may requirethe use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow forthis possibility.

� Refer to your 1771-OBD and 1756-OC8 Installation Manual wiring schematics and diagrams for more details. Ensure1756 output module ratings are not exceeded. [Reference Doc: 41170-937 (Version 01)]

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1

2

3

4

5

67891011121314151617

18

1920212223

242526272829303132333435

3736

ABCD

010203040506071011121314151617

00

DC(+)

DC(-)

DC(+)DC(+)DC(+)

E

LOAD

+

- Output 01Output 02Output 03Output 04Output 05Output 06Output 07Output 10Output 11Output 12Output 13Output 14Output 15Output 16Output 17

Output 00

1771-WH, WHF, WHFB Swing ArmFrom 1771-OBD

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

White/Red/Blue

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/White

Green/Black/White

Orange/Black/White

Blue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

1

3

5

7

468101214161811131517

20

21357

468101214161811131517

2019

9

19

9

DC-0(+)

OUT-0

OUT-1

OUT-2

OUT-3

DC-0(+)DC-0(+)DC-0(+)RTN OUT-0DC-1(+)DC-1(+)DC-1(+)DC-1(+)OUT-4OUT-5OUT-6OUT-7

RTN OUT-1

DC-0(+)OUT-0OUT-1OUT-2OUT-3

DC-0(+)DC-0(+)DC-0(+)RTN OUT-0DC-1(+)DC-1(+)DC-1(+)DC-1(+)OUT-4OUT-5OUT-6OUT-7

RTN OUT-1RTN OUT-1

RTN OUT-0

RTN OUT-1

RTN OUT-0

2

MO

DU

LE B

MO

DU

LE A

Conversion Module1492-CM1771-LD008F

Cable1492-CONCAB005S1� 1756-OC8

1756-OC8

IMPORTANT

52 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 53: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OBDS to 1756-OB16E

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1771-WH, WHF, WHFB Swing ArmFrom 1171-OBDS

� This Bul. 1492 cable consists of a cable wired to one 1756-OB16E RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OBDS module output current limits versus 1756-OB16E limits are as follows: 1771-OBDS 1756-OB16E w/ 1492-CONCAB005Xa) Current/Point 1A 1Ab) Current/Module 8A 8Ac) Surge Current/Point 4A for 10ms 2A for 10ms

� The 1771-OBDS has a single 12A, 250V rectifier fuse (1/4 x 1-1/4 inch). The 1756-OB16E is electronically fused per group. Refer to the 1756-OB16E Installation Manual for details on electronic fusing.

� The 1771-OBDS is rated 10V to 40V DC. The 1756-OB16E is rated 10V to 31.2V DC. If the load source voltage is greaterthan 30V DC, then use the 1756-OC8 with the 1492-CM1771-LD008F conversion module.

� Refer to your 1771-OBDS and 1756-OB16E Installation Manual wiring schematics and diagrams for more details. Ensure1756 output module ratings are not exceeded. [Reference Doc: 41171-005 (Version 00)]

Conversion Module Installation and Application Considerations

Conversion Module1492-CM1771-LD006

Cable1492-CONCAB005X� 1756-OB16E

10DC-0+

OUT-01

OUT-12

OUT-23

OUT-34

OUT-45

OUT-56

OUT-67

OUT-78

OUT-811

OUT-912

OUT-1013

OUT-1114

OUT-1215

OUT-1316

OUT-1417

OUT-1518

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenDC-1+

20

9RTN OUT-0

19RTN OUT-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Output 00

+ dc

- dc

B

CD

dc OutputDevice

Output 01Output 02Output 03Output 04Output 05Output 06Output 07Output 10

Output 11Output 12Output 13Output 14Output 15Output 16Output 17

+

-

+-

+ dc

+ dc

+ dc

24

212223

25

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 53

Page 54: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OBN to 1756-OB32

Conversion Module Installation and Application ConsiderationsThe 1771-OBN module output current limits versus 1756-OB32 limits are as follows:

1771-OBN 1756-OB32w/1492-CONCAB005Za) Current/Point 0.5A 0.35A @ 60˚Cb) Current/Module 8A 6A @ 60˚Cc) Surge Current/Point 2A for 10ms 1A for 10ms

The 1771-OBN has four (4) 4A, 250V rectifier fuses. The 1756-OB32 is NOT fused, as such four (4) 2AG fuse clips and 4A fuses are provided on the 1492-CM1771-LD009F conversion module.

The 1492-CONAB005Z is limited to 3A per pin. The 1771-OBN has 4 groups (allowing 4 separate power supplies) and the 1756-OB32 has 2 groups. This module/cable

combination ties Groups 0 & 1 from the 1771-OBN to Group 0 on the 1756-OB32 and Groups 2 & 3 from the 1771-OBN to Group 1 on the 1756-OB32. Field wiring modification must be made to accommodate this if multiple supplies were used. If 4 supplies were used, 2 must be removed.

Refer to your 1771-OBN and 1756-OB32 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 41170-938 (01)

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

12

345678910

1112131415161718192021222324

25262728293031323334353637

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/White

Green/Black/White

Orange/Black/White

Blue/Black/White

Black/Red/Green

White/Red/Orange

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/OrangeWhite/Red/Orange

Orange/White/Blue

White/Red/Blue

LOAD

+

-

10-30V dc(0)10-30V dc(1)10-30V dc(2)10-30V dc(3)

1836

11922032142252362472582692710281129123013311432153316341735

11121312223234245256267278289291232133314341535163617371838193910203040

DC-0(+)DC-1(+)

OUT-0OUT-16OUT-1OUT-17OUT-2OUT-18OUT-3OUT-19OUT-4OUT-20OUT-5OUT-21OUT-6OUT-22OUT-7OUT-23OUT-8OUT-24OUT-9OUT-25OUT-10OUT-26OUT-11OUT-27OUT-12OUT-28OUT-13OUT-29OUT-14OUT-30OUT-15OUT-31RTN OUT-0RTN OUT-1

Output 00Output 00Output 01Output 01Output 02Output 02Output 03Output 03Output 04Output 04Output 05Output 05Output 06Output 06Output 07Output 07Output 10Output 10Output 11Output 11Output 12Output 12Output 13Output 13Output 14Output 14Output 15Output 15Output 16Output 16Output 17Output 17Common 0Common 1Common 2Common 3

Conversion Module1492-CM1771-LD009F

Cable1492-CONCAB005Z 1756-OB32

1771-WN Swing ArmFrom 1771-OBN

IMPORTANT

54 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 55: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OC to 1756-OC8

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1771-WA Swing ArmFrom 1771-OC

1756-OC8

Conversion Module1492-CM1771-LD014

Cable1492-CONCAB005V�

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-OC8 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OC module output current limits versus 1756-OC8 limits are as follows: 1771-OC 1756-OC8 w/ 1492-CONCAB005Va) Current/Point 1.5A 2Ab) Current/Module 8A 8A @ 60°Cc) Surge Current/Point 4A for 1.0ms 4A for 10ms

� The 1771-OC has eight (8) 2A, 250V fuses - 1 per output. Refer to the 1756-OC8 Installation Manual for details.

� Refer to your 1771-OC and 1756-OC8 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-020 (Version 00)]

B

3

4567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

+DC9

RTN-0OUT-0

1

OUT-13

OUT-25

OUT-37

OUT-4

2

OUT-5

4

OUT-6

6

OUT-7

81214161811131517

RTN-119

10

20RTN-1

LOAD

-DC

+DC

+DC-0+DC-0+DC-0+DC-0+DC-1+DC-1+DC-1+DC-1

1

19

345678910111213

15161718

20

14

2

24

212223

25

RTN

Output 00Output 01Output 02Output 03

Output 04Output 05Output 06Output 07

RTN-0

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 55

Page 56: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OD to 1756-OA16I

41170-994 (01)

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

LOAD

1756-OA16I214365

1492-C005005XM

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

8710912

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

11

L1L21

56789101112

1771-WD Swing ArmFrom 1771-OD

234

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

2 The 1492-COO5005XM is limited to 3A per pin.

2 The 1771-OD module output resistive current limits versus 1756-OA16I limits are as follows:(NOTE: for switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OD 1756-OA16I w/ 1492-CONCAB005XMa) Current/Point 0.2A @ 138V AC 2A @ 240V AC 1A @ 30V DC 2A @ 30V DC 0.25A@ 125V DC 0.25A @ 125V DC

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

3 The 1771-OD module had a jumper selection of N.O. and N.C. outputs. The 1756-OA16I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionalityof the 1771-OD jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O.. If a N.C. output isrequired, change the jumper from pins 1-2 to pins 3-4.

4 Refer to your 1771-OD and 1756-OA16I Installation Manual wiring schematics and diagrams for more details. Ensure1756 output module ratings are not exceeded.

There are several key application considerations and system specifications (bottom of drawing) when usingthese components (conversion module, cable and output module). Read and understand these considerationsbefore installation. In addition, refer to the current draw requirements of the existing loads for this configurationto ensure they are within the current ratings of the 1756 output module.

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

1

56789101112

1771-WD Swing ArmFrom 1771-OD

234

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

252627282930313233343536

NOT USED

NOT USEDNOT USED

141316151817201922212423

L1-6L2-6L1-7

L2-7L1-8L2-8

L2-9L1-9

L2-10L1-10

L1-11L2-11

NOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USED

L1-0

L2-0

L1-1L2-1L1-2L2-2

L2-3L1-3

L2-4L1-4

L1-5L2-5

LOADL1L2

L1-6

L2-6

L1-7L2-7L1-8L2-8

L2-9L1-9

L2-10L1-10

L1-11L2-11

L1-0L2-0L1-1L2-1L1-2L2-2

L2-3L1-3

L2-4L1-4

L1-5L2-5

1492-CM1771-LD012CONVERSION MODULE

1492-CM1771-LD012CONVERSION MODULE

CABLE”A”

CABLE”B”NOT USED

This Bul. 1492 cable consists of 2 separate cables (cable “A” and “B”) wired to one 1756-IM16I RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion.

1

1

IMPORTANT

56 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 57: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OD16 to 1756-OA16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations � This Bul. 1492 cable consists of a cable wired to one 1756-OA16I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OD16 module output current limits versus 1756-OA16I limits are as follows: 1771-OD16 1756-OA16I w/ 1492-CONCAB005Ya) Current/Point 2A 1Ab) Current/Module 8A 4Ab) Surge Current/Point 20A for 100ms 20A for 43ms

� The 1771-OD16 has sixteen (16) 3A ,250V recifier fuses. The 1756-OA16I is NOT fused,as such sixteen (16) 2AG fuseclips are provided on the 1492-CM1771-LD010F conversion module. Max fuse rating is 1.5A based on 1756-OA16I.

� The 1771-OD16 is rated 74V to 138V AC and 105V to 138V DC. The 1756-OA16I is rated 74V to 265V AC. A1756 isolated output module with an equivalent DC voltage range to convert the1771 -OD16 is not available.

� Refer to your 1771-OD16 and 1756-OA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module rating are not exceeded. [Reference Doc: 41170-939 (Version 01)]

10 9

19202143

6 5 8 712111413161518172221242326252827323134333635383729303940

Output 10

Output 12

Output 11

Output 13

Output 2

Output 4

Output 3

Output 5

Not Used

Output 0

Not Used

Output 1

Output 6

Output 8

Output 7

Output 9

L1-14 Output 14

L1-15 Output 15

Not usedNot usedNot usedNot used

12345678910111213

151617181920

14

21222324252627282930313233

353637

34

OUT-0

21

OUT-1

43

OUT-2

65

OUT-3

87

OUT-4

109

OUT-5

1211

OUT-6

1413

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenOUT-7

1615

OUT-8

1817

OUT-9

2019

OUT-10

2221

OUT-11

2423

OUT-12

2625

OUT-13

2827

OUT-14

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueOUT-15

3231

L1-0

L1-1

L1-2

L1-3

L1-4

L1-5

L1-6

L1-7

L1-8

L1-9

L1-10

L1-11

L1-12

L1-13

L1-14

L1-15

L2

Not Used

Not Used

L1-0

L1-1

L1-2

L1-3

L1-4

L1-5

L1-6

L1-7

L1-8

L1-9

L1-10

L1-11

L1-12

L1-13

LOADL1

1771-WN Swing ArmFrom 1771-OD16

Conversion Module1492-CM1771-LD010F

1756-OA16I Cable

1492-CONCAB005Y�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 57

Page 58: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-ODD to 1756-OA16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-OA16I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-ODD module output current limits versus 1756-OA16I limits are as follows: 1771-ODD 1756-OA16I w/ 1492-CONCAB005Ya) Current/Point 2A 2Ab) Current/Module 8A 5Ac) Surge Current/Point 20A for 100ms 20A for 43ms

� The 1771-ODD has sixteen (16) 3A, 250V rectifier fuses. The 1756-OA16I is NOT fused, as such sixteen(16) 2AG fuses and clips are provided on the 1492-CM1771-LD010F conversion module. Max fuse rating is 1.5A based on 1756-OA16I.

� The 1771-ODD is rated 74V to 138V AC. The 1756-OA16I is rated 74V to 265V AC.

� Refer to your 1771-ODD and 1756-OA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-009 (Version 00)]

12345678910111213

151617181920

14

21222324252627282930313233

353637

34

OUT-0

21

OUT-1

43

OUT-2

65

OUT-3

87

OUT-4

109

OUT-5

1211

OUT-6

1413

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenOUT-7

1615

OUT-8

1817

OUT-9

2019

OUT-10

2221

OUT-11

2423

OUT-12

2625

OUT-13

2827

OUT-14

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueOUT-15

3231

L1-0

L1-1

L1-2

L1-3

L1-4

L1-5

L1-6

L1-7

L1-8

L1-9

L1-10

L1-11

L1-12

L1-13

L1-14

L1-15

LOADL1

L2

40

21Ouput 0

3Ouput 1

5Ouput 2

7Ouput 3

11Ouput 4

13Ouput 5

15Ouput 6

17Ouput 7

21Ouput 8

23Ouput 9

25Ouput 10

27Ouput 11

31Ouput 12

33Ouput 13

35Ouput 14

37Ouput 15

L1-0

L1-1

L1-2

L1-3

L1-4

L1-5

L1-6

L1-7

L1-8

L1-9

L1-10

L1-11

L1-12

L1-13

L1-14

L1-15

4

6

8

29

12

14

16

18

30

22

24

26

28

39

32

34

36

38

910

20

19

Not Used

Not UsedNot UsedNot Used

Not Used

Not UsedNot UsedNot Used

1771-WN Swing ArmFrom 1771-ODD

1756-OA16I

Conversion Module1492-CM1771-LD010F

Cable1492-CONCAB005Y�

IMPORTANT

58 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 59: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-ODZ to 1756-OA16I

Conversion Module1492-CM1771-LD012

Conversion Module1492-CM1771-LD012

1771-WD Swing ArmFrom 1771-ODZ

1771-WD Swing ArmFrom 1771-ODZ

Cable1492-C005005XP� 1756-OA16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OA16I RTB. Each cable can be either0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion

� The 1771-ODZ module output resistive current limits versus 1756-OA16I limits are as follows: 1771-ODZ 1756-OA16I w/ 1492-C005005XP a) Current/Point 2A 2A b) Current/Module 6A 5A @ 60°C c) Surge Current/Point 20A for 100ms 20A for 43ms

� The 1771-ODZ module had a jumper selection of N.O. and N.C. outputs. The 1756-OA16I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionalityof the 1771-ODZ jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output isrequired, change the jumper from pins 1-2 to pins 3-4.

� Refer to your 1771-ODZ and 1756-OA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-016 (Version 00)]

2

8

1

4

16

6

5710

912

11

33343536

NOT USED

NOT USEDNOT USED

L1-0L1-0L2-0L2-1

L1-1L1-1

L2-3L2-2

L2-4

L1-2L1-2

L2-5

CABLE”A”

NOT USED

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

LOAD

1492-CONCAB005Y

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

L1

L2

+

- LOAD

1

56789101112

+V0/1

Out-0 N.O./N.C.

234

Out-1 N.O./N.C.

+V2/3

Out-2 N.O./N.C.

Out-3 N.O./N.C.

+V4/5

Out-4 N.O./N.C.

Out-5 N.O./N.C.

+V6/7

Out-6 N.O./N.C.

Out-7 N.O./N.C.

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

14

1315

L1-3

L2-6L2-7

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

LOAD

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

L1

L2

+

- LOAD

1

56789101112

+V0/1

Out-0 N.O./N.C.

234

Out-1 N.O./N.C.

+V2/3

Out-2 N.O./N.C.

Out-3 N.O./N.C.

+V4/5

Out-4 N.O./N.C.

Out-5 N.O./N.C.

+V6/7

Out-6 N.O./N.C.

Out-7 N.O./N.C.

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

L1-4L1-4L2-8L2-9L1-5L1-5

L2-11L2-10

L1-6L1-4

L2-12L2-13

L1-7L1-7

L2-14L2-15

3

L1-3

CABLE”B”18

24

17

20

32

22

212326

2528

27

30

2931

19

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 59

Page 60: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OG to 1756-OG16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

1771-WC Swing ArmFrom 1771-OG

1771-WC Swing ArmFrom 1771-OG

Conversion Module1492-CM1771-LA003

Conversion Module1492-CM1771-LA003

Cable1492-C005005XS� 1756-OG16

OutputDevice

1325242322211918171612

SH

Output 0 + DC 10

OUT-0OUT-1

1

OUT-2

234567

98

Red/White

Green/Black/White

Black/White/Red

White/Black/Red

Orange/Green

Red/Black/White

Orange/Red

Blue/Red

+ -

A

34567B

012

Common

Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7

3456789101112141520

OUT-3OUT-4OUT-5OUT-6OUT-7

+ DC -0

- DC -020

OUT-8OUT-9OUT-10OUT-11OUT-12OUT-13OUT-14OUT-15

+ DC -1

- DC -1

1325242322211918171612

SH

Red/White

Green/Black/White

Black/White/Red

White/Black/Red

Orange/Green

Red/Black/White

Orange/Red

Blue/Red

A

34567B

012

3456789101112141520

Output 8 + DC

Common

Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15

111213141516171819

Black/Red

White/Red

Black/Red

White/Red

CABLE”B”

+

- 5V DCSUPPLY

OutputDevice

+ -

+

- 5V DCSUPPLY

Conversion Module Installation and Application Considerations � This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OG16 RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion.

� The input delay times for the 1771-OG module versus the 1756-OG16 module are as follows: 1771-OG 1756-OG16 w/ 1492-C005005XS a) Off-to-On Delay 1ms (+/-10ms) 45ms max (plus selectable filter) b) On-to-Off Delay 1ms (+/-10ms) 145ms max (plus selectable filter)

� The 1771-OG module is rated 5V DC TTL INPUT MODULE. The 1756-OG16 module is rated 5V DC TTL INPUT MODULE only.

� Refer to your 1771-OG and 1756-OG16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. [Reference Doc: 41171-028 (Version 00)]

CABLE”A”

IMPORTANT

60 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 61: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OGD to 1756-OG16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1771-WH, WHF, WHFB Swing ArmFrom 1171-OGD

� This Bul. 1492 cable consists of a cable wired to one 1756-OG16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OGD module output current limits versus 1756-OG16 limits are as follows: 1771-OGD 1756-OG16 w/ 1492-CONCAB005Xa) Current/Point 1mA 24mAb) Current/Module 310mA 384mA

� The 1771-OGD has a single 10A, 250V rectifier fuse (1/4 x 1-1/4 inch). The 1756-OG16 is electronically fused per group. Refer to the 1756-OG16 Installation Manual for details on electronic fusing.

� The 1771-OGD is rated 10V to 60V DC. The 1756-OG16 is rated 10V to 31.2V DC.

� Refer to your 1771-OGD and 1756-OG16 Installation Manual wiring schematics and diagrams for more details. Ensure1756 output module ratings are not exceeded. [Reference Doc: 41171-006 (Version 00)]

Conversion Module Installation and Application Considerations

Conversion Module1492-CM1771-LD006

Cable1492-CONCAB005X� 1756-OG16

10DC-0+

OUT-01

OUT-12

OUT-23

OUT-34

OUT-45

OUT-56

OUT-67

OUT-78

OUT-811

OUT-912

OUT-1013

OUT-1114

OUT-1215

OUT-1316

OUT-1417

OUT-1518

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenDC-1+

20

9RTN OUT-0

19RTN OUT-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Output 00

+ dc

- dc

B

CD

dc OutputDevice

Output 01Output 02Output 03Output 04Output 05Output 06Output 07Output 10

Output 11Output 12Output 13Output 14Output 15Output 16Output 17

+

-

+-

+ dc

+ dc

+ dc

24

212223

25

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 61

Page 62: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OM to 1756-OA16

1756-OA16

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module1492-CM1771-LD014

Conversion Module1492-CM1771-LD014

Cable1492-C005005XG�

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OA16 RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion.

� The 1771-OM module output current limits versus 1756-OA16 limits are as follows: 1771-OM 1756-OA16 w/ 1492-CONCAB005XGa) Current/Point 2A 0.5 @ 60°Cb) Current/Module 6A 4A @ 60°Cc) Surge Current/Point 20A for 100ms 5A for 43ms

� The 1771-OM module is rated 220V to 240V AC. The 1756-OA16 module is rated 74V to 265V AC only.

� Refer to your 1771-OM and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-022 (Version 00)]

Cable “A”

B

3

4567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

L1-0

L1-0

OUT-01

OUT-12

OUT-23

OUT-34

OUT-4

10

OUT-5OUT-6OUT-7

5678

LOAD

-

+

1

19

345678910111213

15161718

20

14

2

24

212223

25

L2-0

B

3

4567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

OUT-811

OUT-912

OUT-1013

OUT-1114

OUT-12

20

OUT-13OUT-14OUT-15

15161718

LOAD

1

19

345678910111213

15161718

20

14

2

24

212223

25

L2-1

1771-WA Swing ArmFrom 1771-OM

1771-WA Swing ArmFrom 1771-OM

L1-1

OUTPUT 03OUTPUT 02OUTPUT 01OUTPUT 00

OUTPUT 07OUTPUT 06OUTPUT 05OUTPUT 04

L1-1

INPUT 11INPUT 10INPUT 09INPUT 08

INPUT 15INPUT 14INPUT 13INPUT 12

L1

L2

L1

L2

Cable “B”

L2-119

L2-09

IMPORTANT

62 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 63: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OMD to 1756-OA16

Conversion Module1492-CM1771-LD006

Cable1492-CONCAB005X�

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations

10L1-0+

OUT-01

OUT-12

OUT-23

OUT-34

OUT-45

OUT-56

OUT-67

OUT-78

OUT-811

OUT-912

OUT-1013

OUT-1114

OUT-1215

OUT-1316

OUT-1417

OUT-1518

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenL1-1+

20

9L2-0

19L2-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Output 00

L1

L2

B

CD

Output 01Output 02Output 03Output 04Output 05Output 06Output 07Output 10

Output 11Output 12Output 13Output 14Output 15Output 16Output 17

L1

L2

+-

24

212223

25

LOAD

L1

L1

L1

� This Bul. 1492 cable consists of a cable wired to one 1756-OA16 RTB. Recommended cable lengths of0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OMD module output current limits versus 1756-OA16 limits are as follows: 1771-OMD 1756-OA16 w/ 1492-CONCAB005Xa) Current/Point 2A 0.5Ab) Current/Module 8A 4Ac) Surge Current/Point 25A for 100ms 5A for 43ms

� The 1771-OMD has a single 10A, 250V rectifier fuse (1/4 x 1 1/4 inch). The 1756-OA16 has a mechanical 3.15A @250V AC slow blow fuse. Refer to the 1756-OA16 Installation Manual for details on electronic fusing.

� The 1771-OMD is rated 184V to 250V AC. The 1756-OA16 is rated 74V to 265V AC. If the load source voltage is greater than 30V DC, then use the 1756-OC8 with the 1492-CM1771-LD008F conversion module.

� Refer to your 1771-OMD and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-007 (Version 00)]

1756-OA16

1771-WH, WHF, WHFB Swing ArmFrom 1771-OMD

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 63

Page 64: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-ON to 1756-ON8

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

1771-WA Swing ArmFrom 1771-ON

Conversion Module1492-CM1771-LD014

1756-ON8 Cable

1492-CONCAB005W�

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-ON8 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-ON module output current limits versus 1756-ON8 limits are as follows: 1771-ON 1756-ON8 w/ 1492-CONCAB005Wa) Current/Point 1.5A 2Ab) Current/Module 6A 5A @ 60°Cc) Surge Current/Point 4A for 10ms 20A for 43ms

� The 1771-ON has eight (8) 2A, 250V fuses - 1 per output. The 1756-ON8 is electronically fused per point. Refer to the 1756-ON8 Installation Manual for details on electronic fusing.

� Refer to your 1771-ON and 1756-ON8 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-021 (Version 00)]

B

3

4567

A012

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

L1 2NOT USED

OUT-01

OUT-13

OUT-25

OUT-37

OUT-4

4

OUT-5

6

OUT-6

8

OUT-7

101214161811131517

NOT USED19

9

L1-0

20L1-1

LOAD

L2

L1

L1-0L1-0L1-0L1-0L1-1L1-1L1-1L1-1

1

19

345678910111213

15161718

20

14

2

24

212223

25

L2

Output 00Output 01Output 02Output 03

Output 04Output 05Output 06Output 07

IMPORTANT

64 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 65: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OND to 1756-ON8

Conversion Module1492-CM1771-LD006

Cable1492-CONCAB005S2�

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations

� This Bul. 1492 cable consists of a cable wired to two 1756-ON8 RTB. Recommended cable lengths of0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OND module output current limits versus (2)1756-ON8 limits are as follows: 1771-OND 1756-ON8 w/ 1492-CONCAB005S2a) Current/Point 2A 2Ab) Current/Module 8A 5Ac) Surge Current/Point 25A for 100ms 20A for 43ms

� The L2 terminal (Terminal E) on the 1771-ON8 module was an optional connection, but it is required for the 1756-OA16. This connection must be added if it was not connected.

� The 1771-OND is rated 24V AC. The 1756-ON8 is rated 10V to 30V AC.

� Refer to your 1771-OND and 1756-ON8 Installation Manual wiring schematics and diagrams for more details. Ensure1756 output module ratings are not exceeded. [Reference Doc: 41171-008 (Version 00)]

1756-ON8

1756-ON8

10L1-0

OUT-01

OUT-13

OUT-25

OUT-37

OUT-4OUT-5

11

OUT-6

13

OUT-7

1517

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

L1-114

L1-1

A

1

00

19

013

024

035

046

057

068

079

E

10111012111312

13151416151716

17 18

20

14

2

Output 00

L1

L2

1771-WH, WHF Swing ArmFrom 1771-OND

B

CD

L1

L1L1

L1

L2

OutputDevice

Output 01Output 02Output 03Output 04Output 05Output 06Output 07Output 10

Output 11Output 12Output 13Output 14Output 15Output 16Output 17

24

212223

25

L1-0L1-0L1-0L1-0

L1-11618

L1-1L1-1

2468

20

10L1-0

OUT-81

OUT-93

OUT-105

OUT-117

OUT-12OUT-13

11

OUT-14

13

OUT-15

1517

L1-114

L1-1

L1-0L1-0L1-0L1-0

L1-11618

L1-1L1-1

2468

20

NOT USED

NOT USED

NOT USED

19

9

9

NOT USED19

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 65

Page 66: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OQ to 1756-OB16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module1492-CM1771-LA004

Conversion Module1492-CM1771-LA004

1771-WF Swing ArmFrom 1771-OQ

1771-WF Swing ArmFrom 1771-OQ

Cable1492-C005005XT� 1756-OB16I

181716151413121110

987

432

6

1

5

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

18

14131211

8

65

171615

4321

109

7

Black

White

RedGreen

214

3

10

14

13

DC-1OUTPUT-0

OUTPUT 1

DC-2

OUTPUT 2

DC-2

6

8

12

5

9

7

11

15

OUTPUT 3

DC-3

DC-3

DC-4

16DC-4

DC-1

OUTPUT-4

OUTPUT 5OUTPUT 6

OUTPUT 7

LOAD

+

-

LOAD

181716151413121110

987

432

6

1

5

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

18

14131211

8

65

171615

4321

109

7

Black

White

RedGreen

181720

19

26

30

29

DC-1OUTPUT-8

OUTPUT 9

DC-2

OUTPUT 10

DC-2

22

24

28

21

25

23

27

31

OUTPUT 11

DC-3

DC-3

DC-4

32DC-4

DC-1

OUTPUT-12

OUTPUT 13OUTPUT 14

OUTPUT 15

LOAD

+

-

LOAD

NOT USED33343536

NOT USEDNOT USEDNOT USED

Cable “B”

Cable “A”DC-1

OUTPUT-0

OUTPUT 1

DC-2OUTPUT 2

DC-2OUTPUT 3

DC-3

DC-3

DC-4

DC-4

DC-1

OUTPUT-4

OUTPUT 5

OUTPUT 6

OUTPUT 7

Not Used

Not Used

DC-1OUTPUT-8

OUTPUT 9

DC-2OUTPUT 10

DC-2OUTPUT 11

DC-3

DC-3

DC-4

DC-4

DC-1

OUTPUT-12

OUTPUT 13

OUTPUT 14

OUTPUT 15

Not Used

Not Used

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OB16I RTB. Each cable can be either0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion

� The 1771-OQ module output resistive current limits versus 1756-OB16I limits are as follows: 1771-OQ 1756-OB16I w/ 1492-C005005XT a) Current/Point 2.25A 2A b) Current/Module 9A 8A c) Surge Current/Point 4A for 10ms 4A for 10ms

� The 1771-OQ is rated 10V to 32V DC. The 1756-OB16I is rated 10V to 30V DC.

� Refer to your 1771-OQ and 1756-OB16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-033 (Version 00)]

IMPORTANT

66 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 67: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OQ16 to 1756-OB16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

� This Bul. 1492 cable consists of a cable wired to one 1756-OB16I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OQ16 module output current limits versus 1756-OB16I limits are as follows: 1771-OQ16 1756-OB16I w/ 1492-CONCAB005Ya) Current/Point 2A 2Ab) Current/Module 32A 8Ac) Surge Current/Point 4A for 10ms 4A for 10ms

� The 1771-OQ16 has sixteen (16) 3A, 250V rectifier fuses. The 1756-OB16I is NOT fused, as such sixteen(16) 2AG fuses and clips are provided on the 1492-CM1771-LD010F conversion module. Max fuse rating is 1.5A based on 1756-OA16I.

� The 1771-OQ16 is rated 10V to 32V DC. The 1756-OB16I is rated 10V to 30V DC.

� Refer to your 1771-OQ16 and 1756-OB16I Installation Manual wiring schematics and diagrams for more details. Ensure1756 output module ratings are not exceeded. [Reference Doc: 41171-010 (Version 00)]

Conversion Module Installation and Application Considerations

1771-WN Swing ArmFrom 1771-OQ16

12345678910111213

151617181920

14

21222324252627282930313233

353637

34

OUT-0

21

OUT-1

43

OUT-2

65

OUT-3

87

OUT-4

109

OUT-5

1211

OUT-6

1413

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenOUT-7

1615

OUT-8

1817

OUT-9

2019

OUT-10

2221

OUT-11

2423

OUT-12

2625

OUT-13

2827

OUT-14

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueOUT-15

3231

DC-0

DC-1

DC-2

DC-3

DC-4

DC-5

DC-6

DC-7

DC-8

DC-9

DC-10

DC-11

DC-12

DC-13

DC-14

DC-15

+

-

40

21Ouput 0

3Ouput 1

5Ouput 2

7Ouput 3

11Ouput 4

13Ouput 5

15Ouput 6

17Ouput 7

21Ouput 8

23Ouput 9

25Ouput 10

27Ouput 11

31Ouput 12

33Ouput 13

35Ouput 14

37Ouput 15

DC-0

DC-1

DC-2

DC-3

DC-4

DC-5

DC-6

DC-7

DC-8

DC-9

DC-10

DC-11

DC-12

DC-13

DC-14

DC-15

4

6

8

29

12

14

16

18

30

22

24

26

28

39

32

34

36

38

910

20

19

Not Used

Not UsedNot UsedNot Used

Not Used

Not UsedNot UsedNot Used

LOAD

Conversion Module1492-CM1771-LD010F

1756-OB16I Cable

1492-CONCAB005Y�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 67

Page 68: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OR to 1756-OB16I

Conversion Module1492-CM1771-LD012

Conversion Module1492-CM1771-LD012

1771-WD Swing ArmFrom 1771-OR

1771-WD Swing ArmFrom 1771-OR

Cable1492-C005005XR� 1756-OA16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OA16I RTB. Each cable can be either0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion

� The 1771-OR module output resistive current limits versus 1756-OA16I limits are as follows: 1771-OR 1756-OA16I w/ 1492-C005005XR a) Current/Point 2A 2A b) Current/Module 6A 5A @ 60°C c) Surge Current/Point 15A for 100ms 20A for 43ms

� The 1771-OR module had a jumper selection of N.O. and N.C. outputs. The 1756-OA16I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionalityof the 1771-OR jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output isrequired, change the jumper from pins 1-2 to pins 3-4.

� Refer to your 1771-OR and 1756-OA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-017 (Version 00)]

2

1

5

468

9

11

293031

NOT USEDNOT USED

L2-0

L1-0L1-1L1-2

L2-2L2-1

L1-3

L2-3

L1-4

CABLE ”A”

NOT USED

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

1492-CONCAB005Y

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

1

56789101112

0-OUT

0-IN234

1-IN

2-IN

1-OUT

2-OUT

3-OUT

3-IN

4-IN

5-IN4-OUT

5-OUT

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

L1-5

L2-4L2-5

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

LOAD

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

1

56789101112

234

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

3

13

CABLE ”B”

L1L2

LOAD

L1L2

10

12

6-OUT

6-IN

7-IN

8-IN

7-OUT

8-OUT

9-OUT

9-IN

10-IN

11-IN10-OUT

11-OUT

14

15

19

161820

21

23

L2-6

L1-6L1-7L1-8

L2-8L2-7

L1-9

L2-9

L1-10

L1-11

L2-10L2-11

17

25

22

24

262728

NOT USEDNOT USED

NOT USED

343536

NOT USEDNOT USED

NOT USED

3233

NOT USEDNOT USED

IMPORTANT

68 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 69: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OVN to 1756-OV16E

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

10L1-0L2-0

1OUT-0

2OUT-1

3OUT-2

4

OUT-12

5

OUT-13

6

OUT-14

7

OUT-15

81112131415161718

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

12345

78910

18

111213

151617

14

L1-119

9

OUT-3

20

L2-1

OUT-4OUT-5OUT-6OUT-7OUT-8OUT-9OUT-10OUT-11

1771-WN Swing ArmFrom 1771-OVN

10

123456781112131415161718

19

9

20

20 Red/Green

21 Orange/Green

22 Black/White/Red

24 Red/Black/White

25 Green/Black/White

26 Orange/Black/White27 Blue/Black/White28 Black/Red/Green29 White/Red/Green

30 Red/Black/Green

31 Green/Black/Orange

32 Orange/Black/Green33 Blue/White/Orange

34 Black/White/Orange

35 White/Red/Orange

36White/Red/Blue37

A EL

UD

OM

B EL

UD

OM

30

202

40

43

65

87

129

34

13

1

1615

1817

22

19

2423

2625

2827

3229

11

33

10L2L2

L2L2

Output 00Output 01Output 02Output 03Output 04Output 05Output 06Output 07Output 10Output 11

Output 13

Output 15

Output 12

Output 17

L1

35

31

14

L1

21L1

Output 14

Output 16

38

3637

39

L1

Output 00Output 01Output 02Output 03

Output 04Output 05Output 06Output 07Output 10Output 11

Output 13

Output 15

Output 12

Output 17

Output 14

Output 16

Orange/Red

6

L1-0L2-0OUT-0OUT-1OUT-2

OUT-12OUT-13OUT-14OUT-15L1-1

OUT-3

L2-1

OUT-4OUT-5OUT-6OUT-7OUT-8OUT-9OUT-10OUT-11

23 White/Black/Red

Orange/White/Blue

L1

L2

OutputDevice

19 Blue/Red

1756-OV16E

1756-OV16E

Conversion Module1492-CM1771-LD013

Cable1492-CONCAB005S3�

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to two 1756-OV16E RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OVN module output current limits versus 1756-OV16E limits are as follows: 1771-OVN 1756-OV16E w/ 1492-CONCAB005S3a) Current/Point 0.5A 1Ab) Current/Module 8A (32 pts) 8A (16 pts)c) Surge Current/Point 2A for 10ms 2A for 10ms

� The 1771-OVN has 4 groups (allowing 4 separate power supplies). This module/cable combination ties all 4 groups from the 1771-OVN together. Field wiring modification must be made to accommodate this if mulitple supplies were used. If more than 1 supply was used, all but 1 of the power supplies must be removed.

� The 1771-OVN did not allow connections for L2, however the 1756-OV16E requires an L2 connection for proper operation. The 1771-OVN did not use terminals 10, 20, 30, 40. These terminals have been reassigned for an L2 connection in this application. The installer must rewire L2 to one of these terminals.

� Refer to your 1771-OVN and 1756-OV16E Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded.

� This configuration uses two (2) 1756-OV16E output modules to replace a single 1771-OVN output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility.

[Reference Doc: 41171-018 (Version 00)]

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 69

Page 70: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OW to 1756-OX8I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module1492-CM1771-LD012

1771-WD Swing ArmFrom 1771-OW

Cable1492-CONCAB005Y�

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-OX8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M), 010=1.0M). See table 2 for other lengths.

� The 1771-OW module output resistive current limits versus 1756-OX8I limits are as follows:(NOTE: For switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OW 1756-OX8I w/ 1492-CONCAB005Y a) Current/Point 0.2A @ 138V AC 2A @ 240V AC 1A @ 30V DC 2A @ 30V DC 0.25A @ 125V DC 0.25A @ 125V DC

� The 1771-OW module had a jumper selection of N.O. and N.C. outputs. The 1756-OX8I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionalityof the 1771-OW jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output isrequired, change the jumper from pins 1-2 to pins 3-4.

� Refer to your 1771-OW and 1756-OX8I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41170-941 (Version 01)]

4 3

2 1

N.C.

N.O.

4 3

2 1

N.C.

N.O.

4 3

2 1

N.C.

N.O.

4 3

2 1

N.C.

N.O.

4 3

2 1

N.C.

N.O.

4 3

2 1

N.C.

N.O.

L1-0OUT-0 N.C.L1-0

OUT-0 N.O.L1-1OUT-1 N.C.L1-1OUT-1 N.O.L1-2OUT-2 N.C.L1-2OUT-2 N.O.L1-3OUT-3 N.C.L1-3OUT-3 N.O.L1-4OUT-4 N.C.

L1-4OUT-4 N.O.L1-5OUT-5 N.C.L1-5OUT-5 N.O.L1-6OUT-6 N.C.

L1-6OUT-6 N.O.L1-7OUT-7 N.C.L1-7

OUT-7 N.O.

12

345678910

1112131415161718

192021222324

25262728293031323334353637

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/White

Green/Black/White

Orange/Black/White

Blue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/Blue

4 3

2 1

N.C.

N.O.

JMP74 3

2 1

N.C.

N.O.

JMP6

JMP5

JMP4

JMP3

JMP2

JMP1

JMP0

1234

56

789

101112

LOAD

L1

L2

LOAD

+

-

Out-0 N.O./N.C.+V0/1

Out-1 N.O./N.C.Out-2 N.O./N.C.

+V2/3Out-3 N.O./N.C.Out-4 N.O./N.C.

+V4/5Out-5 N.O./N.C.

Out-6 N.O./N.C.+V6/7

Out-7 N.O./N.C.

2143658710912111413161518172019222124232625282730293231

1756-OX8I

IMPORTANT

70 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 71: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OW16 to 1756-OW16I

Conversion Module Installation and Application Considerations� The 1771-OW16 module output resistive current limits versus 1756-OW16I limits are as follows: 1771-OW16 1756-OW16I w/ 1492-CONCAB005Ya) Current/Point 2A @ 250V AC 2A @ 240V AC 2A @ 30V DC 2A @ 30V DC 0.3A @ 150V DC 0.25A @ 125V AC� The 1492-CONCAB005Y is limited to 3A per pin.� The 1771-OW16 has N.O. and N.C. relay contact outputs. The 1756-OW16I has N.O. relay contact outputs only. The conver-sion module does not convert the N.C. to N.O. contacts. If the 1771-OW16 N.C. outputs were being used, the installer must rewire the 1771-WN swing arm and move the N.C. wires to the N.O. output terminals. In addition, the control Logix programming will need to be changed to simulate a N.C. relay with this output.� Refer to your 1771-OW16 and 1756-OW16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. Reference Doc: 41170-940 (Version 01)]

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1 2

17202326

4

365

8

71091211141316151918

2221252428

273130

3433

37364039

29323538

Output 14 (NO)

Output 16 (NO)

Output 15 (NO)

Output 04

Output 06

Output 05

Output 07

Output 00

Output 02

Output 01

Output 03

Output 10 (NO)

Output 12 (NO)

Output 11(NO)

Output 13 (NO)

Output 17 (NO)Output 14 (NC)Output 15 (NC)Output 16 (NC)Output 17 (NC)

12345678910111213

151617181920

14

21222324252627282930313233

353637

34

OUT-0 N.O.

21

OUT-1 N.O.

43

OUT-2 N.O.

65

OUT-3 N.O.

87

OUT-4 N.O.

109

OUT-5 N.O.

1211

OUT-6 N.O.

1413

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenOUT-7 N.O.

1615

OUT-8 N.O.

1817

OUT-9 N.O.

2019

OUT-10 N.O.

2221

OUT-11 N.O.

2423

OUT-12 N.O.

2625

OUT-13 N.O.

2827

OUT-14 N.O.

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueOUT-15 N.O.

3231

L1-0

L1-1

L1-2

L1-3

L1-4

L1-5

L1-6

L1-7

L1-8

L1-9

L1-10

L1-11

L1-12

L1-13

L1-14

L1-15

L1

L2

Common 00

Common 01

Common 02

Common 03

Common 04

Common 05

Common 06

Common 07

Common 10

Common 11

Common 12

Common 13

Common 14

Common 15

Common 16

Common 17

Output 10 (NC)Output 11 (NC)Output 12 (NC)Output 13 (NC)

+

- LOAD

LOAD

Conversion Module1492-CM1771-LD011

Cable1492-CONCAB005Y� 1756-OW16I

1771-WN Swing ArmFrom 1771-OW16

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 71

Page 72: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OWNA to 1756-OW16I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1771-WN Swing ArmFrom 1771-OWNA

2L1-0L2-0

1OUT-0

3OUT-1

5OUT-2

7

OUT-12

9

OUT-13

11

OUT-14

13

OUT-15

151719212325272931

Black

WhiteRed

Green

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

12345

78910

18

111213

151617

14

L1-1

OUT-3

4

L1-1

OUT-4OUT-5OUT-6OUT-7OUT-8OUT-9OUT-10OUT-11

20 Red/Green

21 Orange/Green

22 Black/White/Red

24 Red/Black/White

25 Green/Black/White

26 Orange/Black/White27 Blue/Black/White28 Black/Red/Green29 White/Red/Green

30 Red/Black/Green

31 Green/Black/Orange

32 Orange/Black/Green33 Blue/White/Orange

34 Black/White/Orange

35 White/Red/Orange

36White/Red/Blue37

AB

ELU

DO

MEL

UD

OM

30

202

40

43

65

87

129

34

13

1

1615

1817

22

19

2423

2625

2827

3229

11

33

10L2L2

L2L2

Output 00Output 01Output 02Output 03Output 04Output 05Output 06Output 07Output 10Output 11

Output 13

Output 15

Output 12

Output 17

L1

35

31

14

L1

21L1

Output 14

Output 16

38

3637

39

L1

Output 00Output 01Output 02Output 03

Output 04Output 05Output 06Output 07Output 10Output 11

Output 13

Output 15

Output 12

Output 17

Output 14

Output 16

Orange/Red

6

23 White/Black/Red

Orange/White/Blue

L1

L2

OutputDevice

19 Blue/Red

L1-1

L1-1

6

3234

2L1-0L2-0

1OUT-0

3OUT-1

5OUT-2

7

OUT-12

9

OUT-13

11

OUT-14

13

OUT-15

151719212325272931

L1-1

OUT-3

4

L1-1

OUT-4OUT-5OUT-6OUT-7OUT-8OUT-9OUT-10OUT-11

L1-1

L1-1

6

3234

1756-OW16I

1756-OW16I

Conversion Module1492-CM1771-LD013

Cable1492-CONCAB005S4�

��

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to two 1756-OW16I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� The 1771-OWNA module output current limits versus 1756-OW16I limits are as follows: 1771-OWNA 1756-OW16I w/ 1492-CONCAB005S4a) Current/Point 1A 0.5Ab) Current/Module 12A (32 pts) 2A (16 pts)

� The 1771-OWNA has 4 groups (allowing 4 separate power supplies). This module/cable combination ties all 4 groups from the 1771-OWNA together. Field wiring modification must be made to accommodate this if mulitple supplies were used. If more than 1 supply was used, all but 1 of the power supplies must be removed.

� The 1771-OWNA did not allow connections for L2, however the 1756-OW16I requires an L2 connection for proper operation. The 1771-OWNA did not use terminals 10, 20, 30, 40. These terminals have been reassigned for an L2 connection in this application. The installer must rewire L2 to one of these terminals.

� Refer to your 1771-OWNA and 1756-OW16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded.

� This configuration uses two (2) 1756-OW16I output modules to replace a single 1771-OWNA output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility.

� 1756-OW16I output modules has all inputs jumpered together pins 2 through 34 even. [Reference Doc: 41171-019 (Version 00)]

IMPORTANT

72 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 73: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OY to 1756-OX8I

41171-011 (00)

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

LOAD

1756-OX8I

OUT-0 N.C.

21

OUT-0 N.O.

43

OUT-1 N.C.

65

OUT-1 N.O.

87

OUT-2 N.C.

109

OUT-2 N.O.

1211

OUT-3 N.C.

1413

1492-CONCAB005YOrange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenOUT-3 N.O.

1615

OUT-4 N.C.

1817

OUT-4 N.O.

2019

OUT-5 N.C.

2221

OUT-5 N.O.

2423

OUT-6 N.C.

2625

OUT-6 N.O.

2827

OUT-7 N.C.

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueOUT-7 N.O.

3231

L1-0

L1-0

L1-1

L1-1

L1-2

L1-2

L1-3

L1-3

L1-4

L1-4

L1-5

L1-5

L1-6

L1-6

L1-7

L1-7

L1

L2

+

- LOAD

1

56789101112

1492-CM1771-LD012

+V0/1

Out-0 N.O./N.C.

1771-WD Swing ArmFrom 1771-OY

234

Out-1 N.O./N.C.

+V2/3

Out-2 N.O./N.C.

Out-3 N.O./N.C.

+V4/5

Out-4 N.O./N.C.

Out-5 N.O./N.C.

+V6/7

Out-6 N.O./N.C.

Out-7 N.O./N.C.

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

The 1771-OY module output resistive current limits versus 1756-OX8I limits are as follows: (NOTE: for switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OY 1756-OX8I w/ 1492-CONCAB005Y a) Current/Point 100mA @ 138V AC 2A @ 240V AC 100mA @ 125V DC 2A @ 30V DC 0.25A @ 125V DC

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

The 1771-OY module had a jumper selection of N.O. and N.C. outputs. The 1756-OX8I has both N.O. and N.C. relay outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-OY jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O.. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4.

Refer to your 1771-OY and 1756-OX8I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded.

There are several key application considerations and system specifications (bottom of drawing) when usingthese components (conversion module, cable and output module). Read and understand these considerationsbefore installation. In addition, refer to the current draw requirements of the existing loads for this configurationto ensure they are within the current ratings of the 1756 output module.

Conversion Module

Cable

This Bul. 1492 cable consists of a cable wired to one 1756-OX8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 73

Page 74: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OYL to 1756-OX8I

41171-012 (00)

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

LOAD

1756-OX8I

OUT-0 N.C.

21

OUT-0 N.O.

43

OUT-1 N.C.

65

OUT-1 N.O.

87

OUT-2 N.C.

109

OUT-2 N.O.

1211

OUT-3 N.C.

1413

1492-CONCAB005Y

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenOUT-3 N.O.

1615

OUT-4 N.C.

1817

OUT-4 N.O.

2019

OUT-5 N.C.

2221

OUT-5 N.O.

2423

OUT-6 N.C.

2625

OUT-6 N.O.

2827

OUT-7 N.C.

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueOUT-7 N.O.

3231

L1-0

L1-0

L1-1

L1-1

L1-2

L1-2

L1-3

L1-3

L1-4

L1-4

L1-5

L1-5

L1-6

L1-6

L1-7

L1-7

L1

L2

+

- LOAD

1

56789101112

1492-CM1771-LD012

+V0/1

Out-0 N.O./N.C.

1771-WD Swing ArmFrom 1771-OYL

234

Out-1 N.O./N.C.

+V2/3

Out-2 N.O./N.C.

Out-3 N.O./N.C.

+V4/5

Out-4 N.O./N.C.

Out-5 N.O./N.C.

+V6/7

Out-6 N.O./N.C.

Out-7 N.O./N.C.

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

The 1771-OYL module output resistive current limits versus 1756-OX8I limits are as follows: (NOTE: for switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OYL 1756-OX8I w/ 1492-CONCAB005Y a) Current/Point 100mA @ 24V AC 2A @ 240V AC 100mA @ 24V DC 2A @ 30V DC 0.25A @ 125V DC

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

The 1771-OYL module had a jumper selection of N.O. and N.C. outputs. The 1756-OX8I has both N.O. and N.C. relay outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-OYL jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O.. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4.

Refer to your 1771-OYL and 1756-OX8I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded.

There are several key application considerations and system specifications (bottom of drawing) when usingthese components (conversion module, cable and output module). Read and understand these considerationsbefore installation. In addition, refer to the current draw requirements of the existing loads for this configurationto ensure they are within the current ratings of the 1756 output module.

Cable

This Bul. 1492 cable consists of a cable wired to one 1756-OX8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

Conversion Module

IMPORTANT

74 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 75: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OZ to 1756-OX8I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

1771-WD Swing ArmFrom 1771-OZ

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-OX8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M), 010=1.0M). See table 2 for other lengths.

� The 1771-OZ module output resistive current limits versus 1756-OX8I limits are as follows:(NOTE: For switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OZ 1756-OX8I w/ 1492-CONCAB005Y a) Current/Point 100mA @ 138V AC 2A @ 240V AC 100mA @ 138V DC 2A @ 30V DC 0.25A @ 125V DC

� The 1771-OZ module had a jumper selection of N.O. and N.C. outputs. The 1756-OX8I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionalityof the 1771-OZ jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output isrequired, change the jumper from pins 1-2 to pins 3-4.

� Refer to your 1771-OZ and 1756-OX8I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-013 (Version 00)]

Cable1492-CONCAB005Y� 1756-OX8I

Conversion Module1492-CM1771-LD012

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

LOAD

OUT-0 N.C.

21

OUT-0 N.O.

43

OUT-1 N.C.

65

OUT-1 N.O.

87

OUT-2 N.C.

109

OUT-2 N.O.

1211

OUT-3 N.C.

1413

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenOUT-3 N.O.

1615

OUT-4 N.C.

1817

OUT-4 N.O.

2019

OUT-5 N.C.

2221

OUT-5 N.O.

2423

OUT-6 N.C.

2625

OUT-6 N.O.

2827

OUT-7 N.C.

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueOUT-7 N.O.

3231

L1-0

L1-0

L1-1

L1-1

L1-2

L1-2

L1-3

L1-3

L1-4

L1-4

L1-5

L1-5

L1-6

L1-6

L1-7

L1-7

L1

L2

+

- LOAD

1

56789101112

+V0/1

Out-0 N.O./N.C.

234

Out-1 N.O./N.C.

+V2/3

Out-2 N.O./N.C.

Out-3 N.O./N.C.

+V4/5

Out-4 N.O./N.C.

Out-5 N.O./N.C.

+V6/7

Out-6 N.O./N.C.

Out-7 N.O./N.C.

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 75

Page 76: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Digital Outputs

1771-OZL to 1756-OX8I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

1771-WD Swing ArmFrom 1771-OZL

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to one 1756-OX8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M), 010=1.0M). See table 2 for other lengths.

� The 1771-OZL module output resistive current limits versus 1756-OX8I limits are as follows:(NOTE: For switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OZL 1756-OX8I w/ 1492-CONCAB005Y a) Current/Point 100mA @ 138V AC 2A @ 240V AC 100mA @ 138V DC 2A @ 30V DC 0.25A @ 125V DC

� The 1771-OZL module had a jumper selection of N.O. and N.C. outputs. The 1756-OX8I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionalityof the 1771-OZL jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output isrequired, change the jumper from pins 1-2 to pins 3-4.

� Refer to your 1771-OZL and 1756-OX8I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-014 (Version 00)]

Cable1492-CONCAB005Y� 1756-OX8I

Conversion Module1492-CM1771-LD012

12345

678910111213

151617181920

14

21222324252627282930313233

353637

34

LOAD

OUT-0 N.C.

21

OUT-0 N.O.

43

OUT-1 N.C.

65

OUT-1 N.O.

87

OUT-2 N.C.

109

OUT-2 N.O.

1211

OUT-3 N.C.

1413

Orange

Blue

White/Black

Red/BlackGreen/Black

Orange/BlackBlue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/GreenOUT-3 N.O.

1615

OUT-4 N.C.

1817

OUT-4 N.O.

2019

OUT-5 N.C.

2221

OUT-5 N.O.

2423

OUT-6 N.C.

2625

OUT-6 N.O.

2827

OUT-7 N.C.

3029

Orange/Green

Black/White/Red

White/Black/Red

Red/Black/WhiteGreen/Black/White

Orange/Black/WhiteBlue/Black/White

Black/Red/Green

White/Red/Green

Red/Black/Green

Green/Black/Orange

Orange/Black/Green

Blue/White/Orange

Black/White/Orange

White/Red/Orange

Orange/White/BlueOUT-7 N.O.

3231

L1-0

L1-0

L1-1

L1-1

L1-2

L1-2

L1-3

L1-3

L1-4

L1-4

L1-5

L1-5

L1-6

L1-6

L1-7

L1-7

L1

L2

+

- LOAD

1

56789101112

+V0/1

Out-0 N.O./N.C.

234

Out-1 N.O./N.C.

+V2/3

Out-2 N.O./N.C.

Out-3 N.O./N.C.

+V4/5

Out-4 N.O./N.C.

Out-5 N.O./N.C.

+V6/7

Out-6 N.O./N.C.

Out-7 N.O./N.C.

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP0

JMP1

1

3

2

4

N.O.

N.C.

JMP2

1

3

2

4

N.O.

N.C.

1

3

2

4

N.O.

N.C.

JMP3

JMP4

1

3

2

4

N.O.

N.C.

JMP5

1

3

2

4

N.O.

N.C.

JMP6

1

3

2

4

N.O.

N.C.

JMP7

IMPORTANT

76 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 77: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IFE to 1756-IF16 Differential Current

41170-946 (0)

1

6

7 8 9

5 10 15 20

19

21

11 12 13 14 16 17 18

1492-CM1771-LA002

1771-WG Swing Arm

2

3 4

1492-CONACAB005D

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Orange/Black

Blue/Black

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

1 2 3 4 5 6 7 8 9 10 11 12 13

14 15 16 17 18 19 20 21

SH

Not Used

Channel 1+

Channel 1-

Channel 2+ Channel 2-

Channel 3+ Channel 3- Channel 4+ Channel 4-

Not Used Not Used

Module Common Module Common

Channel 5+

Channel 5- Channel 6+ Channel 6- Channel 7+ Channel 7- Channel 8+ Channel 8-

22 23 24 25

2 4 6 8 12 14 16 18 10

22 20

26 24

36 34 32 30

5 1

15 11

23 19

33

IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 R TN

IN-9 IN-8

IN-11 IN-10

IN-15 IN-14 IN-13 IN-12

iR TN-2 iR TN-0

iR TN-6 iR TN-4

iR TN-10 iR TN-8

iR TN-14 iR TN-12

29

TransmitterPower Supply +

-

4-Wire Transmitter

+ -

1756-IF16

3 The 1771-IFE analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16.

1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA002 module. The pre-wired cable used between the 1492-CM1771-LA002 module and the 1756-IF16 [1492-CONACAB005D] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

2 This design assumes that all inputs on the1771-IFE were connected to current transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005D] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details.

4 Refer to your 1771-IFE and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

WARNING There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and output module). Read and understand these considerations before installation.

1

1

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 77

Page 78: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IFE to 1756-IF16 Differential Voltage

41170-947 (1)

1

6

7 8 9

5 10 15 20

19

21

11 12 13 14 16 17 18

1492-CM1771-LA002

1771-WG Swing Arm

2

3 4

1492-CONACAB005C

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Orange/Black

Blue/Black

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

1 2 3 4 5 6 7 8 9 10 11 12 13

14 15 16 17 18 19 20 21

SH

Not Used

Channel 1+

Channel 1-

Channel 2+ Channel 2-

Channel 3+ Channel 3- Channel 4+ Channel 4-

Not Used Not Used

Module Common Module Common

Channel 5+

Channel 5- Channel 6+ Channel 6- Channel 7+ Channel 7- Channel 8+ Channel 8-

22 23 24 25

1756-IF16 2

IN-0 IN-1

4

IN-2 6

IN-3 8

IN-4 12

IN-5 14

IN-6 16

IN-7 18

R TN 10

IN-9 22

IN-8 20

IN-11 26

IN-10 24

IN-15 36

IN-14 34

IN-13 32

IN-12 30

3 The 1771-IFE analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16.

1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA002 module. The pre-wired cable used between the 1492-CM1771-LA002 module and the 1756-IF16 [1492-CONACAB005C] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

2 This design assumes that all inputs on the1771-IFE were connected to voltage transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005C] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details.

4 Refer to your 1771-IFE and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

TransmitterPower Supply+

-

4-Wire Transmitter

+ -

1

1

IMPORTANT

78 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 79: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IFE to 1756-IF16 Single End Current

41170-944 (1)

1

6

7 8 9

5 10 15 20

19

21

11 12 13 14 16 17 18

1492-CM1771-LA001

1771-WG Swing Arm

2

3 4

1756-IF16 2

IN-0 IN-1

4

IN-2 6

IN-3 8

IN-4 12

IN-5 14

IN-6 16

IN-7 18

R TN 10

R TN

27 R TN

28

IN-9 22

IN-8 20

IN-11 26

IN-10 24

IN-15 36

IN-14 34

1492-CONACAB005B

Black

R TN 9

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

IN-13 32

IN-12 30

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

iR TN-1 3

iR TN-0 1

iR TN-3 7

iR TN-2 5

iR TN-7 17

iR TN-6 15

iR TN-5 13

iR TN-4 11

iR TN-9 21

iR TN-8 19

iR TN-11 25

iR TN-10 23

iR TN-15 35

iR TN-14 33

iR TN-13 31

iR TN-12 29

1 2 3 4 5 6 7 8 9 10 11 12 13

14 15 16 17 18 19 20 21

SH

Module Common T r ansmitt er

P o w er Supply +

2-W ir e T r ansmitt er

-

Channel 1

Channel 2

Channel 3 Channel 4

Channel 5 Channel 6 Channel 7 Channel 8

Module Common Module Common Module Common Module Common

Channel 9

Channel 10 Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 Channel 16

22 23 24 25

3 The 1771-IFE analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16.

1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA001 module. The pre-wired cable used between the 1492-CM1771-LA001 module and the 1756-IF16 [1492-CONACAB005B] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

2 This design assumes that all inputs on the1771-IFE were connected to current transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005B] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details.

4 Refer to your 1771-IFE and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

WARNING There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

1

1

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 79

Page 80: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IFE to 1756-IF16 Single End Voltage

41170-945 (1)

1

6

7 8 9

5 10 15 20

19

21

11 12 13 14 16 17 18

1492-CM1771-LA001

1771-WG Swing Arm

2

3 4

1756-IF16 1492-CONACAB005A

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

1 2 3 4 5 6 7 8 9 10 11 12 13

14 15 16 17 18 19 20 21

SH

Module Common

Channel 1

Channel 2

Channel 3 Channel 4

Channel 5 Channel 6 Channel 7 Channel 8

Module Common Module Common Module Common Module Common

Channel 9

Channel 10 Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 Channel 16

22 23 24 25

T r ansmitt er

P o w er Supply

+ -

3-W ir e T r ansmitt er 2

IN-0 IN-1

4

IN-2 6

IN-3 8

IN-4 12

IN-5 14

IN-6 16

IN-7 18

R TN 10

R TN

27 R TN

28

IN-9 22

IN-8 20

IN-11 26

IN-10 24

IN-15 36

IN-14 34

R TN 9

IN-13 32

IN-12 30

3 The 1771-IFE analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16.

1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA001 module. The pre-wired cable used between the 1492-CM1771-LA001 module and the 1756-IF16 [1492-CONACAB005A] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

2 This design assumes that all inputs on the1771-IFE were connected to voltage transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005A] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details.

4 Refer to your 1771-IFE and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

WARNING There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

1

1

IMPORTANT

80 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 81: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IFF to 1756-IF16 Differential Current

41171-025 (00)

1

6

789

5101520

19

21

11121314161718

1492-CM1771-LA002

1771-WG Swing ArmFrom 1771-IFF

2

34

1492-CONACAB005DBlack

White

Red

Green

Orange

Blue

White/Black

Red/Black

Orange/Black

Blue/Black

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

12345678910111213

1415161718192021

SH

Not Used

Channel 1+

Channel 1-

Channel 2+Channel 2-

Channel 3+Channel 3-Channel 4+Channel 4-

Not UsedNot Used

Module CommonModule Common

Channel 5+

Channel 5-Channel 6+Channel 6-Channel 7+Channel 7-Channel 8+Channel 8-

22232425

24681214161810

2220

2624

36343230

51

1511

2319

33

IN-0IN-1IN-2IN-3IN-4IN-5IN-6IN-7RTN

IN-9IN-8

IN-11IN-10

IN-15IN-14IN-13IN-12

iRTN-2iRTN-0

iRTN-6iRTN-4

iRTN-10iRTN-8

iRTN-14iRTN-12

29

TransmitterPower Supply+

-

4-Wire Transmitter

+ -

1756-IF16

The 1771-IFF analog input ranges were configured via software, as is the input range for the 1756-IF16. Pleaseensure the correct input range is configured in the 1756-IF16.

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connectedto the grounding stud on the 1492-CM1771-LA002 module. The pre-wired cable used between the 1492-CM1771-LA002module and the 1756-IF16 [1492-CONACAB005D] provides a shield ground lug to ground the shield at the 1756ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

This design assumes that all inputs on the1771-IFF were connected to current transmitters. If there was a mix of currentand voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005D] will need to occur at the 1756-IF16terminal block. Refer to the 1756-IF16 Installation Manual for modification details.

Refer to your 1771-IFF and 1756-IF16 Installation and User Manuals for additional information concerning comparisonsof module wiring, features and configuration details.

WARNING There are several key application considerations and system specifications (bottom of drawing) when usingthese components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

Conversion ModuleCable

This Bul. 1492 cable consists of a cable wired to one 1756-IF16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 81

Page 82: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IFF to 1756-IF16 Differential Voltage

41171-026 (00)

1

6

789

5101520

19

21

11121314161718

1492-CM1771-LA002

1771-WG Swing ArmFrom 1771-IFF

2

34

1492-CONACAB005C

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Orange/Black

Blue/Black

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

12345678910111213

1415161718192021

SH

Not Used

Channel 1+

Channel 1-

Channel 2+Channel 2-

Channel 3+Channel 3-Channel 4+Channel 4-

Not UsedNot Used

Module CommonModule Common

Channel 5+

Channel 5-Channel 6+Channel 6-Channel 7+Channel 7-Channel 8+Channel 8-

22232425

1756-IF162

IN-0IN-1

4

IN-26

IN-38

IN-412

IN-514

IN-616

IN-718

RTN10

IN-922

IN-820

IN-1126

IN-1024

IN-1536

IN-1434

IN-1332

IN-1230

The 1771-IFF analog input ranges were configured via software, as is the input range for the 1756-IF16. Pleaseensure the correct input range is configured in the 1756-IF16.

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connectedto the grounding stud on the 1492-CM1771-LA002 module. The pre-wired cable used between the 1492-CM1771-LA002module and the 1756-IF16 [1492-CONACAB005C] provides a shield ground lug to ground the shield at the 1756ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

This design assumes that all inputs on the1771-IFF were connected to voltage transmitters. If there was a mix of currentand voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005C] will need to occur at the 1756-IF16terminal block. Refer to the 1756-IF16 Installation Manual for modification details.

Refer to your 1771-IFF and 1756-IF16 Installation and User Manuals for additional information concerning comparisonsof module wiring, features and configuration details.

There are several key application considerations and system specifications (bottom of drawing) when usingthese components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

TransmitterPower Supply+

-

4-Wire Transmitter

+ -

This Bul. 1492 cable consists of a cable wired to one 1756-IF16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

Conversion Module Cable

IMPORTANT

82 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 83: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IFF to 1756-IF16 Single End Current

41171-023 (00)

1

6

789

5101520

19

21

11121314161718

1492-CM1771-LA001

1771-WG Swing ArmFrom 1771-IFF

2

34

1756-IF162

IN-0IN-1

4

IN-26

IN-38

IN-412

IN-514

IN-616

IN-718

RTN10

RTN

27RTN

28

IN-922

IN-820

IN-1126

IN-1024

IN-1536

IN-1434

1492-CONACAB005BBlack

RTN9

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

IN-1332

IN-1230

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

iRTN-13

iRTN-01

iRTN-37

iRTN-25

iRTN-717

iRTN-615

iRTN-513

iRTN-411

iRTN-921

iRTN-819

iRTN-1125

iRTN-1023

iRTN-1535

iRTN-1433

iRTN-1331

iRTN-1229

12345678910111213

1415161718192021

SH

Module CommonTransmitter

Power Supply+

2-Wire Transmitter

-

Channel 1

Channel 2

Channel 3Channel 4

Channel 5Channel 6Channel 7Channel 8

Module CommonModule CommonModule CommonModule Common

Channel 9

Channel 10Channel 11Channel 12Channel 13Channel 14Channel 15Channel 16

22232425

The 1771-IFF analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16.

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA001 module. The pre-wired cable used between the 1492-CM1771-LA001 module and the 1756-IF16 [1492-CONACAB005B] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

This design assumes that all inputs on the1771-IFF were connected to current transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005B] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details.

Refer to your 1771-IFF and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

Conversion ModuleCable

This Bul. 1492 cable consists of a cable wired to one 1756-IF16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 83

Page 84: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IFF to 1756-IF16 Single End Voltage

41171-024 (00)

1

6

789

5101520

19

21

11121314161718

1492-CM1771-LA001

1771-WG Swing ArmFrom 1771-IFF

2

34

1756-IF161492-CONACAB005ABlack

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

Orange/Green

12345678910111213

1415161718192021

SH

Module Common

Channel 1

Channel 2

Channel 3Channel 4

Channel 5Channel 6Channel 7Channel 8

Module CommonModule CommonModule CommonModule Common

Channel 9

Channel 10Channel 11Channel 12Channel 13Channel 14Channel 15Channel 16

22232425

Transmitter

Power Supply

+ -

3-Wire Transmitter2

IN-0IN-1

4

IN-26

IN-38

IN-412

IN-514

IN-616

IN-718

RTN10

RTN

27RTN

28

IN-922

IN-820

IN-1126

IN-1024

IN-1536

IN-1434

RTN9

IN-1332

IN-1230

The 1771-IFF analog input ranges were configured via software, as is the input range for the 1756-IF16. Pleaseensure the correct input range is configured in the 1756-IF16.

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connectedto the grounding stud on the 1492-CM1771-LA001 module. The pre-wired cable used between the 1492-CM1771-LA001module and the 1756-IF16 [1492-CONACAB005A] provides a shield ground lug to ground the shield at the 1756ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

This design assumes that all inputs on the1771-IFF were connected to voltage transmitters. If there was a mix of currentand voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005A] will need to occur at the 1756-IF16terminal block. Refer to the 1756-IF16 Installation Manual for modification details.

Refer to your 1771-IFF and 1756-IF16 Installation and User Manuals for additional information concerning comparisonsof module wiring, features and configuration details.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

This Bul. 1492 cable consists of a cable wired to one 1756-IF16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

Conversion ModuleCable

IMPORTANT

84 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 85: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IL to 1756-IF8I Current

The 1771-IL input configuration was software configured, as is the 1756-IF8I. Please ensure the correct configuration in the 1756-IF8I.

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF8I [1492-CONACAB005K8] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

Refer to your 1771-IL and 1756-IF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

There are several key application considerations and system specifications (bottom of drawing) when usingthese components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

This Bul. 1492 cable consists of a cable wired to one 1756-IF6I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M).

18

1492-CM1771-LA004

1716151413121110

987

SH

432

6

1

5

1492-CONACAB005K8

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

18

14131211

8

65

1771-WF Swing ArmFrom 1771-IL

171615

4321

109

7

Channel6 Channel7Channel7 Orange

Blue

White / BlackRed / Black

Channel5 Channel5Channel6

Channel4Channel4

Channel3 Channel3

Channel0

Channel2Channel2

Channel1Channel1

Channel0 TransmitterPower Supply

+

-

4-Wire Transmitter

+ -

2-WireTransmitter

+

-

Conversion ModuleCable 1756-IF8I

4

3027

11

12

20

3

28

19

5

6

13

14

21

22

29

Iin_CH0RTN_CH0Iin_CH1RTN_CH1Iin_CH2RTN_CH2Iin_CH3RTN_CH3

Iin_CH4RTN_CH4Iin_CH5RTN_CH5Iin_CH6

RTN_CH7Iin_CH7RTN_CH6

2625

32

31

3433

2

1

98

1510

1716

23

18

7

24N.C.N.C.

N.C.N.C.N.C.N.C.N.C.N.C.N.C.

N.C.N.C.

N.C.

3635

N.C.N.C.

N.C.N.C.N.C.N.C.N.C.

N.C.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 85

Page 86: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IL to 1756-IF8I Voltage

There are several key application considerations and system specifications (bottom of drawing) when usingthese components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

The 1771-IL input configuration was software configured, as is the 1756-IF8I. Please ensure the correct configuration in the 1756-IF8I.

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF8I [1492-CONACAB005L8] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

Refer to your 1771-IL and 1756-IF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

This Bul. 1492 cable consists of a cable wired to one 1756-IF8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M).

18

1492-CM1771-LA004

1716151413121110

987

SH

432

6

1

5

1492-CONACAB005L8

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

18

14131211

8

65

1771-WF Swing ArmFrom 1771-IL

171615

4321

109

7

TransmitterPower Supply+

-

4-Wire Transmitter

+ -

Conversion ModuleCable

3

1756-IF8I

2

3025

9

10

18

1

26

17

3

5

6

13

14

21

22

29

Vout_CH0RTN_CH0Vout_CH1RTN_CH1Vout_CH2RTN_CH2Vout_CH3RTN_CH3

Vout_CH4RTN_CH4Vout_CH5RTN_CH5Vout_CH6

RTN_CH7Vout_CH7RTN_CH6

2724

31

28

3332

4

3

35

8

1211

1615

2019

7

23N.C.N.C.

N.C.N.C.N.C.N.C.N.C.N.C.N.C.

N.C.N.C.

N.C.

36

34

N.C.N.C.

N.C.N.C.N.C.N.C.N.C.

N.C.

Vout_CH0RTN_CH0Vout_CH1RTN_CH1Vout_CH2RTN_CH2Vout_CH3RTN_CH3

Vout_CH4RTN_CH4Vout_CH5RTN_CH5Vout_CH6

RTN_CH7Vout_CH7RTN_CH6

Orange

Blue

White / BlackRed / Black

IMPORTANT

86 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 87: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IL to 1756-IF6I — 6-ch Current

41171-030 (00)

18

1492-CM1771-LA004

1716151413121110

987

SH

432

6

1

5

1492-CONACAB005K

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

18

14131211

8

65

1771-WF Swing ArmFrom 1771-IL

171615

4321

109

7

Channel6 Channel7Channel7

1756-IF6I

Black

White

RedGreen

Channel5 Channel5Channel6

Channel4Channel4

Channel3 Channel3

Channel0

Channel2Channel2

Channel1Channel1

Channel0

The 1771-IL input configuration was software configured, as is the 1756-IF6I. Please ensure the correct configuration in the 1756-IF6I.

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF6I [1492-CONACAB005K] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

Refer to your 1771-IL and 1756-IF6I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

53

64

119

1210

1917

16152018

1

278

RET-0

IN-0/I

IN-1/V

IN-4/IRET-4IN-5/IRET-5

TransmitterPower Supply+

-

4-Wire Transmitter

+ -

RET-1

IN-1/I

IN-0/V

RET-3

IN-3/I

IN-2/VIN-3/V

RET-2IN-2/I

IN-4/VIN-5/V

This Bul. 1492 cable consists of a cable wired to one 1756-IF6I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

2-WireTransmitter

+

-

Conversion ModuleCable

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 87

Page 88: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IL to 1756-IF6I — 6-ch Voltage

41171-029 (00)

18

1492-CM1771-LA004

1716151413121110

987

SH

432

6

1

5

1492-CONACAB005L

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

18

14131211

8

65

1771-WF Swing ArmFrom 1771-IL

171615

4321

109

7

1756-IF6I

Black

White

RedGreen

ARNING There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

152

47

118

12

1718

1915

1413

2016

109

RET-0IN-0

RET-1IN-1

RET-2IN-2

RET-3

IN-4RET-4IN-5RET-5

NO CONNECTNO CONNECT

TransmitterPower Supply+

-

2-Wire Transmitter

+ -

IN-3

43 NO CONNECT

NO CONNECTNO CONNECTNO CONNECTNO CONNECTNO CONNECT

Conversion ModuleCable

The 1771-IL input configuration was software configured, as is the 1756-IF6I. Please ensure the correct configuration in the 1756-IF6I.

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF6I [1492-CONACAB005L] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

Refer to your 1771-IL and 1756-IF6I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

This Bul. 1492 cable consists of a cable wired to one 1756-IF6I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

Channel6 Channel7Channel7

Channel5 Channel5Channel6

Channel4Channel4

Channel3 Channel3

Channel0

Channel2Channel2

Channel1Channel1

Channel0

IMPORTANT

88 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 89: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IL to 1756-IF6I — (2 x 4-ch) Current

Conversion Module1492-CM1771-LA004

1771-WF Swing ArmFrom 1771-IL

Cable1492-CONACAB005T1� 1756-IF6I

1756-IF6I

Conversion Module Installation and Application Considerations� This Bul. 1492 cable consists of a cable wired to two 1756-IF6I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

� SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF6I [1492-CONACAB005T1] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

� The 1771-IL input configuration was software configured, as is the 1756-IF6I. Please ensure the correct configuration in the 1756-IF6I.

� Refer to your 1771-IL and 1756-IF6I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

� This configuration uses two (2) 1756-IF6I output modules to replace a single 1771-IL output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility. [Reference Doc: 41171-032 (Version 00)]

181716151413121110

987

SH

432

6

1

5

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

18

14131211

8

65

171615

4321

109

7

Channel6 Channel7Channel7 Black

White

RedGreen

Channel5 Channel5Channel6

Channel4Channel4

Channel3 Channel3

Channel0

Channel2Channel2

Channel1Channel1

Channel0 53

64

119

1210

1917

16152018

1

278

RET-0

IN-0/I

IN-1/V

IN-4/IRET-4IN-5/IRET-5

TransmitterPower Supply+

-

4-Wire Transmitter

+ -

RET-1

IN-1/I

IN-0/V

RET-3

IN-3/I

IN-2/VIN-3/V

RET-2IN-2/I

IN-4/VIN-5/V

2-WireTransmitter

+

-

��

53

64

119

1210

1917

16152018

1

278

RET-0

IN-0/I

IN-1/V

IN-4/IRET-4IN-5/IRET-5

RET-1

IN-1/I

IN-0/V

RET-3

IN-3/I

IN-2/VIN-3/V

RET-2IN-2/I

IN-4/VIN-5/V

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 89

Page 90: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IL to 1756-IF6I — (2 x 4-ch) Voltage

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1771-WF Swing ArmFrom 1771-IL

Conversion Module1492-CM1771-LA004 Cable

1492-CONACAB005T2 1756-IF6I

1756-IF6I

Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to two 1756-IF6I RTB. Recommended cable lengths of 0.5M or

1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF6I [1492-CONACAB005T2] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

The 1771-IL input configuration was software configured, as is the 1756-IF6I. Please ensure the correct configuration in the 1756-IF6I.

Refer to your 1771-IL and 1756-IF6I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

This configuration uses two (2) 1756-IF6I output modules to replace a single 1771-IL output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility. 41171-031 (00)

181716151413121110

987

SH

432

6

1

5

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

18

14131211

8

65

171615

4321

109

7

Black

White

RedGreen

152

67

118

12

1718

1915

1413

2016

109

RET-0IN-0

RET-1IN-1

RET-2IN-2

RET-3

IN-4RET-4IN-5RET-5

NO CONNECTNO CONNECT

TransmitterPower Supply+

-

4-Wire Transmitter

+ -

IN-3

43 NO CONNECT

NO CONNECTNO CONNECTNO CONNECTNO CONNECTNO CONNECT

Channel6 Channel7Channel7

Channel5 Channel5Channel6

Channel4Channel4

Channel3 Channel3

Channel0

Channel2Channel2

Channel1Channel1

Channel0

152

47

118

12

1718

1915

1413

2016

109

RET-0IN-0

RET-1IN-1

RET-2IN-2

RET-3

IN-4RET-4IN-5RET-5

NO CONNECTNO CONNECT

IN-3

43 NO CONNECT

NO CONNECTNO CONNECTNO CONNECTNO CONNECTNO CONNECT

2-WireTransmitter

+

-

IMPORTANT

90 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 91: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IR to 1756-IRT8I

181716151413121110

987

SH

432

6

1

5

18

14131211

8

65

171615

4321

109

7

Channel6 - CChannel6 - BChannel6 - A

643

10

87

1412

1811

2022

1516

19262423

3-Wire RTD

2-Wire RTD

Channel5 - CChannel5 - BChannel5 - A

Channel4 - C

Channel4 - BChannel4 - A

Channel3 - CChannel3 - B

Channel3 - A

Channel2 - C

Channel2 - BChannel2 - A

Channel1 - CChannel1 - B

Channel1 - A

WARNING There are several key application considerations and system sp cations (bottom of drawing) when usingthese components (conversion module, cable and output module). Read and understand these considerationsbefore installation.

IN_0/RTD C

IN_1/RTD C

IN_1(-)/B

IN_1(+)/A

IN_2/RTD C

IN_2(-)/B

IN_2(+)/A

IN_3/RTD C

IN_3(-)/B

IN_3(+)/A

IN_4/RTD C

IN_4(-)/B

IN_4(+)/A

IN_5(+)/A

IN_5(-)/B

IN_5/RTD C

3130

33

32

3534

2

1

139

2117

2725

28

5

29N.C.N.C.

N.C.N.C.N.C.N.C.N.C.N.C.

N.C.N.C.

N.C.

36

N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.

IN_0(+)AIN_0(-)/B

Conversion Module Installation and Application Considerations� Cables are available in lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M)

� shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IRT8I [1492-CONACAB005F8] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

� Refer to your 1771-IR and 1756-IRT8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and

Cable�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 91

Page 92: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IR to 1756-IR6I

41170-950 (1)

18

1492-CM1771-LA004

17 16 15 14 13 12 11 10

9 8 7

SH

4 3 2

6

1

5

1492-CONACAB005F

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

18

14 13 12 11

8

6 5

1771-WF Swing Arm

17 16 15

4 3 2 1

10 9

7

Channel6 - C Channel6 - B Channel6 - A

1756-IR6I

5

IN-0/A

R TN-0/C 3

IN-1/A

1

R TN-1/C 6

IN-2/A

4

R TN-2/C

2

IN-3/A

11

R TN-3/C

9

R TN-4/C

12

IN-4/A

7

IN-0/B

17

IN-3/B

19

R TN-5/C

8

IN-5/A

10

IN-1/B

15

IN-2/B

20

IN-4/B

18 IN-5/B

16

3-W ir e R TD

2-W ir e R TD

Black

White

Red Green

Channel5 - C Channel5 - B Channel5 - A

Channel4 - C

Channel4 - B Channel4 - A

Channel3 - C Channel3 - B

Channel3 - A

Channel2 - C

Channel2 - B Channel2 - A

Channel1 - C Channel1 - B

Channel1 - A

2 The 1771-IR input configuration was software configured, as is the 1756-IR6I. Please ensure the correct configuration in the 1756-IR6I.

1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IR6I [1492-CONACAB005F] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

3 Refer to your 1771-IR and 1756-IR6I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

WARNING There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

1

1

IMPORTANT

92 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 93: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IXE to 1756-IT6I2

41170-951 (1)

1492-CM1771-LA005

SH

Input 1+

1756-IT6I2 5

IN-0 R TN-0

6

IN-1 7

R TN-1 8

IN-2 9

R TN-2 10

IN-3 11

R TN-3 12

R TN-4 14

IN-4 13

CJC- 4

CJC+ 3

1492-CONACAB005G

R TN-5 16

IN-5 15

T her mo c ouple

+

-

T

18

14 13 12 11

8

6 5

1771-WI Swing Arm

17 16 15

4 3 2 1

10 9

7

Input 1- Input 2+ Input 2- Input 3+ Input 3- Input 4+ Input 4-

Input 5+ Input 5- Input 6+ Input 6-

18 17 16 15 14 13 12 11 10 9 8 7 6 5

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

4 3 2 1

2 The 1771-IXE has 8 input channels. The 1756-IT6I2 only has 6 input channels. This module combination can only be used to convert the signals if 6 or less channels were used on the 1771-IXE.

1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA005 module. The pre-wired cable used between the 1492-CM1771-LA005 module and the 1756-IT6I2 [1492-CONACAB005G] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

3 The 1771-IXE has built CJC (cold junction compensation) into the swing-arm. The conversion module [1492-CM1771-LA005] passes this CJC signal to the 1756-IT6I2. Ensure that the 1756-IT6I2 is configured for external CJC.

4 The 1771-IXE input configuration was software configured, as is the 1756-IT6I2. Please ensure the correct configuration in the 1756-IT6I2.

5 Refer to your 1771-IXE and 1756-IT6I2 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

1

1

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 93

Page 94: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IXE to 1756-IRT8I

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module , cable and input module). Read and understand these considerations bef ore installation.

1492-CM1771-LA005 SER “B”

SH

1492-CONACAB005G8Thermocouple

+

-

T

18

14131211

8

65

1771-WI Swing ArmFrom 1771-IXE

171615

4321

109

7

18171615141312111098765

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

4321

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA005 SER”B” module. The pre-wired cable used between the 1492-CM1771-LA005 SER”B” module and the 1756-IRT8I [1492-CONACAB005G8] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

The 1771-IXE has built CJC (cold junction compensation) into the swing-arm. The conversion module [1492-CM1771-LA005 SER”B”] passes this CJC signal to the 1756-IRT8I. Ensure that the 1756-IRT8I is configured for external CJC.

The 1771-IXE input configuration was software configured, as is the 1756-IRT8I. Please ensure the correct configuration in the 1756-IRT8I.

Refer to your 1771-IXE and 1756-IRT8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

Conversion ModuleCable

This Bul. 1492 cable consists of a cable wired to one 1756-IRT8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M).

1756-IRT8I3

32

31

15

11

19

7

27

23

2

8

4

16

12

24

20

28

1 CJC+CJC-

In_CH0+In_CH0-In_CH1+In_CH1- In_CH2+In_CH2- In_CH3+In_CH3-

In_CH4+In_CH4- In_CH5+In_CH5-

In_CH6+In_CH6-

In_CH7+In_CH7-

2625

3029

96

1310

1714

21185

22

N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.N.C.N.C.N.C.N.C.

N.C.

N.C.N.C.

Blue

Orange

Red/Black

White/Black

CJC+CJC-

In_CH0+In_CH0-In_CH1+In_CH1- In_CH2+In_CH2- In_CH3+In_CH3-

In_CH4+In_CH4- In_CH5+In_CH5- In_CH6+In_CH6-

In_CH7+In_CH7-

IMPORTANT

94 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 95: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IXHR to 1756-IT6I2

41171-035 (00)

1492-CM1771-LA005

SH

Input 1+

1756-IT6I25

IN-0RTN-0

6

IN-17

RTN-18

IN-29

RTN-210

IN-311

RTN-312

RTN-414

IN-413

CJC-4

CJC+3

1492-CONACAB005G

RTN-516

IN-515

Thermocouple

+

-

T

18

14131211

8

65

1771-WI Swing ArmFrom 1771-IXHR

171615

4321

109

7

Input 1-Input 2+Input 2-Input 3+Input 3-Input 4+Input 4-

Input 5+Input 5-Input 6+Input 6-

18171615141312111098765

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

4321

The 1771-IXHR has 8 input channels. The 1756-IT6I2 only has 6 input channels. This module combination can only be used to convert the signals if 6 or less channels were used on the 1771-IHER.

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA005 module. The pre-wired cable used between the 1492-CM1771-LA005 module and the 1756-IT6I2 [1492-CONACAB005G] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

The 1771-IXHR has built CJC (cold junction compensation) into the swing-arm. The conversion module [1492-CM1771-LA005] passes this CJC signal to the 1756-IT6I2. Ensure that the 1756-IT6I2 is configured for external CJC.

The 1771-IXHR input configuration was software configured, as is the 1756-IT6I2. Please ensure the correct configuration in the 1756-IT6I2.

Refer to your 1771-IXHR and 1756-IT6I2 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

There are several key application considerations and system specifications (bottom of drawing) when usingthese components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

Conversion ModuleCable

This Bul. 1492 cable consists of a cable wired to one 1756-IT6I2 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 95

Page 96: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-IXHR to 1756-IRT8I

1492-CM1771-LA005 SER “B”

SH

1492-CONACAB005G8Thermocouple

+

-

T

18

14131211

8

65

1771-WI Swing ArmFrom 1771-IXHR

171615

4321

109

7

18171615141312111098765

Orange/Red

White/Red

Green/White

Blue/White

Orange/Black

Red/White

Black/Red

Blue/Black

Black/White

Green/Black

Blue

Orange

Red/Black

White/Black

4321

SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA005 SER”B” module. The pre-wired cable used between the 1492-CM1771-LA005 SER”B” module and the 1756-IRT8I [1492-CONACAB005G8] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

The 1771-IXHR has built CJC (cold junction compensation) into the swing-arm. The conversion module [1492-CM1771-LA005 SER”B”] passes this CJC signal to the 1756-IRT8I. Ensure that the 1756-IRT8I is configured for external CJC.

The 1771-IXHR input configuration was software configured, as is the 1756-IRT8I. Please ensure the correct configuration in the 1756-IRT8I.

Refer to your 1771-IXHR and 1756-IRT8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

There are several key application considerations and system specifications (bottom of drawing) when usingthese components (conversion module, cable and input module). Read and understand these considerationsbefore installation.

Conversion ModuleCable

This Bul. 1492 cable consists of a cable wired to one 1756-IRT8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M).

1756-IRT8I3

32

31

15

11

19

7

27

23

2

8

4

16

12

24

20

28

1 CJC+CJC-

In_CH0+In_CH0-In_CH1+In_CH1- In_CH2+In_CH2- In_CH3+In_CH3-

In_CH4+In_CH4- In_CH5+In_CH5-

In_CH6+In_CH6-

In_CH7+In_CH7-

2625

3029

96

1310

1714

21185

22

N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.N.C.N.C.N.C.N.C.

N.C.

N.C.N.C.

Blue

Orange

Red/Black

White/Black

CJC+CJC-

In_CH0+In_CH0-In_CH1+In_CH1- In_CH2+In_CH2- In_CH3+In_CH3-

In_CH4+In_CH4- In_CH5+In_CH5- In_CH6+In_CH6-

In_CH7+In_CH7-

IMPORTANT

96 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 97: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-OFE1 to 1756-OF6VI

41170-949 (1)

1492-CM1771-LA003

SH

Channel 1 Out +

Not Used

1756-OF6VI 1

OUT-0 R TN-0

5

OUT-1 2

R TN-1 6

OUT-2 7

R TN-2 11

OUT-3 8

R TN-3 12

R TN-4 19

OUT-4 15

N ot U sed 14

N ot U sed 13

1492-CONACAB005E

20 16

VoltageLoad

+ -

A

3 4 5 6 7 B

1771-WC Swing Arm

0 1 2

Not Used

Channel 1 Out -

Channel 2 Out + Channel 2 Out - Channel 3 Out + Channel 3 Out - Channel 4 Out + Channel 4 Out -

2 The 1771-OFE1 analog output range was configured by jumpers, the output range for the 1756-OF6VI is software configured. Please ensure the correct output range is configured in the 1756-OF6VI.

1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF6VI [1492-CONACAB005E] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

3 Refer to your 1771-OFE1 and 1756-OF6VI Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and output module). Read and understand these considerations before installation.

1

1

Red/White

Green/Black/White

Black/White/Red

White/Black/Red

Orange/Green

Red/Black/White

Orange/Red

Blue/Red

Not UsedNot Used

13252423222119181716123456789101112141520

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 97

Page 98: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-OFE1 to 1756-OF8I

using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations� Cables are available in lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M)

� shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-CONACAB005E8V] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

� Refer to your 1771-OFE1 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and

1771-WC Swing ArmFrom 1771-OFE1

Conversion Module1492-CM1771-LA003

Cable1492-CONACAB005E8V� 1756-OF8I

1325242322211918171612

SH

Channel 1 Out +

Not Used

2OUT_0/VRTN_0

6

OUT_1/V1

RTN_15

OUT_2/V10

RTN_214

OUT_3/V9

RTN_313

VoltageLoad

+ -

A

34567B

012

Not Used

Channel 1 Out -

Channel 2 Out +Channel 2 Out -Channel 3 Out +Channel 3 Out -Channel 4 Out +Channel 4 Out -

3456789101112141520�

2928

31

30

3332

11

8

1615

1817

2019

26

12

27N.C.N.C.

N.C.N.C.N.C.N.C.N.C.N.C.

N.C.N.C.

N.C.

34

N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.

2423

2574

3N.C.N.C.

N.C. N.C.N.C.N.C.

22

21 3536

N.C.N.C.

N.C.N.C.

IMPORTANT

98 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 99: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-OFE1(2) to 1756-OF8I

using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OF8I. Each cable can be either 0.5M or 1.0M (005=0.5M,010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion.

shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-C005005E8V] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

� Refer to your 1771-OFE1 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and

DIR 10002306858 (Version 00)

1771-WC Swing ArmFrom 1771-OFE1

Conversion Module1492-CM1771-LA003

1492-C005005E8V Cable “A”

1756-OF8I

1325242322211918171612

SH

Channel 1 Out +

Not Used

2OUT_0/VRTN_0

6

OUT_1/V1

RTN_15

OUT_2/V10

RTN_214

OUT_3/V9

RTN_313

� � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � �

� � � � � � �

VoltageLoad

+ -

A

34567B

012

Not Used

Channel 1 Out -

Channel 2 Out +Channel 2 Out -Channel 3 Out +Channel 3 Out -Channel 4 Out +Channel 4 Out -

3456789101112141520�

2724

31

28

3332

3

87

1211

1615

4

23N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

34

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

20

19 3536

N.C.

N.C.

N.C.

N.C.

1771-WC Swing ArmFrom 1771-OFE1

Conversion Module1492-CM1771-LA003 Cable “B”

1325242322211918171612

SH

Channel 1 Out +

Not Used

18OUT_4/VRTN_4

22

OUT_5/V17

RTN_521

OUT_6/V26

RTN_630

OUT_7/V25

RTN_729

� � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � �

� � � � � � �

VoltageLoad

+ -

A

34567B

012

Not Used

Channel 1 Out -

Channel 2 Out +Channel 2 Out -Channel 3 Out +Channel 3 Out -Channel 4 Out +Channel 4 Out -

3456789101112141520�

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 99

Page 100: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-OFE2 to 1756-OF6CI

41170-948 (1)

1756-OF6CI

CurrentLoad

13

1492-CM1771-LA003

2524232221191817 1612

SH

Channel 1 Out +

Not Used

1

1 OUT-0 R TN-0

5

OUT-1 2

R TN-1 6

OUT-2 7

R TN-2 11

OUT-3 8

R TN-3 12

R TN-4 19

OUT-4 15

N ot U sed 14

N ot U sed 13

1492-CONACAB005E

Red/White

Green/Black/White

Black/White/Red

White/Black/Red

Orange/Green

Red/Black/White

Orange/Red

Not Used20

Not Used16

Blue/Red

+ -

A

3 4 5 6 7 B

1771-WC Swing Arm

0 1 2

Not Used

Channel 1 Out -

Channel 2 Out + Channel 2 Out - Channel 3 Out + Channel 3 Out - Channel 4 Out + Channel 4 Out -

34 56789101112141520

3 The 1771-OFE2 analog output ranges were factory set, the output range for the 1756-OF6CI is software configured. Please ensure the correct output range is configured in the 1756-OF6CI.

1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF6CI [1492-CONACAB005E] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

2 IMPORTANT: The 1771-OFE2 module required the use of an external power supply to drive the analog device. The 1756-OF6CI analog output provides the drive power to the analog device. ENSURE the external power supply is REMOVED from the current loop before applying power to the 1756-OF6CI module or the analog output module may be damaged.

4 The 1756-OF6CI module can drive a load up to 550 ohms with the standard pre-configured cable [1492-CONACAB005E]. If greater than a 550 ohm drive current is required, the pre-wired cable can be modified at the 1756-OF6CI terminal block to drive up to a 1000 ohms. Refer to the 1756-OF6CI Installation Manual for modification details. 5 Refer to your 1771-OFE2 and 1756-OF6CI Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details.

WARNING There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and output module). Read and understand these considerations before installation.

1

IMPORTANT

100 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 101: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-OFE2 to 1756-OF8I

using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

Conversion Module Installation and Application Considerations� Cables are available in lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M)

� shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-CONACAB005E8C] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

� Refer to your 1771-OFE1 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and

DIR 10002306853 (Version 00)

1771-WC Swing ArmFrom 1771-OFE2

Conversion Module1492-CM1771-LA003

Cable1492-CONACAB005E8C� 1756-OF8I

1325242322211918171612

SH

Channel 1 Out +

Not Used

4OUT_0/IRTN_0

6

OUT_1/I3

RTN_15

OUT_2/I12

RTN_214

OUT_3/I11

RTN_313

CurrentLoad

+ -

A

34567B

012

Not Used

Channel 1 Out -

Channel 2 Out +Channel 2 Out -Channel 3 Out +Channel 3 Out -Channel 4 Out +Channel 4 Out -

3456789101112141520�

2928

31

30

3332

9

8

1615

1817

2019

26

10

27N.C.N.C.

N.C.N.C.N.C.N.C.N.C.N.C.

N.C.N.C.

N.C.

34

N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.

2423

2572

1N.C.N.C.

N.C. N.C.N.C.N.C.

22

21 3536

N.C.N.C.

N.C.N.C.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 101

Page 102: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - Analog Inputs and Outputs

1771-OFE2(2) to 1756-OF8I

using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OF8I. Each cable can be either 0.5M or 1.0M (005=0.5M,010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion.

shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-C005005E8C] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud.

� Refer to your 1771-OFE2 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and

DIR 10002306859 (Version 00)

1771-WC Swing ArmFrom 1771-OFE1

Conversion Module1492-CM1771-LA003

1492-C005005E8C Cable “A”

1756-OF8I

1325242322211918171612

SH

Channel 1 Out +

Not Used

4OUT_0/IRTN_0

6

OUT_1/I3

RTN_15

OUT_2/I12

RTN_214

OUT_3/I11

RTN_313

� � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � �

� � � � � � �

CurrentLoad

+ -

A

34567B

012

Not Used

Channel 1 Out -

Channel 2 Out +Channel 2 Out -Channel 3 Out +Channel 3 Out -Channel 4 Out +Channel 4 Out -

3456789101112141520�

2524

31

26

3332

1

87

1615

1615

2

23N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

34

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

18

17 3536

N.C.

N.C.

N.C.

N.C.

1771-WC Swing ArmFrom 1771-OFE1

Conversion Module1492-CM1771-LA003 Cable “B”

1325242322211918171612

SH

Channel 1 Out +

Not Used

20OUT_4/IRTN_4

22

OUT_5/I19

RTN_521

OUT_6/I28

RTN_630

OUT_7/I27

RTN_729

� � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � �

� � � � � � �

CurrentLoad

+ -

A

34567B

012

Not Used

Channel 1 Out -

Channel 2 Out +Channel 2 Out -Channel 3 Out +Channel 3 Out -Channel 4 Out +Channel 4 Out -

3456789101112141520�

IMPORTANT

102 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 103: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated AnalogStandard High Resolution I/O

1771-NOC to 1756-OF8I

[Reference Doc: DIR 10002306650]

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

3

2

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1CURRENT LOAD

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

15

418

721

1024

13

6

4

15

418

721

1024

13

3

14

12

11

OUT_0/I

OUT_1/I

OUT_2/I

OUT_3/I

RTN_0

RTN_2

1492-CONACAB020N88

22

20

19

30

28

27

OUT_4/I

OUT_5/I

OUT_6/I

OUT_7/I

RTN_4

RTN_6

Cable”A”

Cable”B”

2524

31

26

3332

1

87

109

1615

2

23N.C.

N.C.N.C.N.C.N.C.N.C.N.C.

N.C.N.C.

34

N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.

18

17 3536

N.C.N.C.

N.C.N.C.

21 RTN_5

29 RTN_7

13 RTN_3

5 RTN_1

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

Follow your PLC Analog User Manual for proper shield grounding instructions.

Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. cable does not connect to these terminals.

Interface Module

1771-RTP3 or 1771-RTP4

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 103

Page 104: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NOC to 1756-OF8

41171-079 (00)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

RTP3 OR RTP4

3

2

4

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

1756-OF8

CURRENT LOAD

5

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

15

418

721

1024

13

5

3

1516

41819

72122

10242513

9

15

13

19

Black

White

Green

Orange

White/Black

White/Red

White/Orange

Gray

Black

White

Green

Orange

White/Black

White/Red

White/Orange

Gray

I-OUT-0

I-OUT-1

I-OUT-2

I-OUT-3

I-RTN

I-RTN

1492-CONACAB020N8

1 Cables are available in 2.0m, or 5.0m

2 Terminals starting with A are the lower row of terminals, B terminals are the upper row.

3 Follow your PLC Analog User Manual for propershield grounding instructions.

4 RTN terminals are internally connected on the 1756-OF8.

5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only truefor modules RTP3 and RTP4. The Bul. 1492cable does not connect to these terminals.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

6 The 1771 - NOC module provides channel to channel isolation, the 1756-OF8 does not. A conversion from 1771-NOC to an isolated 1756-OF8 is avalible.

5

3

9

15

13

19

I-OUT-0

I-OUT-1

I-OUT-2

I-OUT-3

I-RTN

I-RTN

1492-CONACAB020N8

6

Cable”A”

Cable”B”

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

IMPORTANT

104 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 105: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NOC to 1756-OF6CI

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1756-OF6CI

1756-OF6CI Cable “A”1492-CONACAB020N1

Cable “B”1492-CONACAB020N1

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

Interface Module 1771-RTP3 or RTP4

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1CURRENT LOAD

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

15

418

721

1024 5

1

2

6

11

7

8

12

Black

White

Green

Orange

White/Black

White/Red

White/Orange

Gray

Black

White

Green

Orange

White/Black

White/Red

White/Orange

Gray

OUT-0

OUT-1

OUT-2

OUT-3

RTN-0

RTN-1

RTN-2

RTN-3

N/A

N/A

N/A

13

5

1

2

6

11

7

8

12

N/A

N/A

N/A

+

-

OUT-0

OUT-1

OUT-2

OUT-3

RTN-0

RTN-1

RTN-2

RTN-315

418

721

1024

13

Conversion Module Installation and Application Considerations Cables are available in 2.0m, or 5.0m

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

Follow your PLC Analog User Manual for proper shield grounding instructions.

RTN terminals are internally connected on the 1756-OF6CI.

Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for modules RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. [Reference Doc: 41171-072 (Version 00)]

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 105

Page 106: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIS to 1756-IF8I

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

3

2

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425

N/A

N/A

N/A

4 N/A

N/A

N/A

1492-CONACAB020N38

CURRENT LOAD

-

CURRENT LOAD

-

+

24VDCSUPPLY

24VDCSUPPLY

+

1516

1819

2122

2425

29 RTN_7

2625

32

31

3433

2

1

98

1510

1716

23

7

24N.C.N.C.

N.C.N.C.N.C.N.C.N.C.N.C.

N.C.N.C.

N.C.

35

N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.

27 IN_7/I/SRC

CABLE “B”

CABLE “A”

30 RTN_628 IN_6/I/SRC

21 RTN_519 IN_5/I/SRC

22 RTN_420 IN_4/I/SRC

13 RTN_311 IN_3/I/SRC

14 RTN_212 IN_2/I/SRC

5 RTN_13 IN_1/I/SRC

6 RTN_04 IN_0/I/SRC

18 N.C. 36 N.C.

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

Follow your PLC Analog User Manual for proper shield grounding instructions.

for module RTP4. The Bul. 1492 .slanimret eseht ot tcennoc ton seod elbac

DIR 10002306457 (Version 00)

using these components (conversion module, cable and input module). Read and understand these considerations before installation.

WARNING

Interface Module

IMPORTANT

106 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 107: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIS to 1756-IF6CIS

41171-073 (01)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

1771-RTP4

3

2

4

W2SH

W3

I7

I6

I5

I4

I3

I2

I0

I1

R7

R6

R5

R4

R3

R2

R1

R0

1756-IF6CIS

CURRENT LOAD

5

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O7

O6

O5

O4

O3

O2

O0

O1

S7

S6

S5

S4

S3

S2

S1

S0

1 Cables are available in 2.0m, or 5.0m

2 Terminals starting with A are the lower row of terminals, B terminals are the upper row.

3 Follow your PLC Analog User Manual for propershield grounding instructions.

4 RTN terminals are internally connected on the 1756-IF6CIS.

5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only truefor modules RTP4. The Bul. 1492cable does not connect to these terminals.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

N/A

N/A

N/A

N/A

N/A

N/A

-

4

1492-CONACAB020N2

1492-CONACAB020N2

CURRENT LOAD

+

-24VDCSUPPLY

24VDCSUPPLY

+

Cable “B”

Cable “A”

1516

1819

2122

2425

13

10

7

4

53

46

119

10

12

I-RTN-4

I-RTN-5

I-RTN-6

I-RTN-7

I-IN-4

I-IN-6

I-IN-7

I-IN-5

1

2

7

8

V-OUT-4

V-OUT-6

V-OUT-7

V-OUT-5

CURRENT LOAD

+

-

1516

1819

2122

2425

13

10

7

4

53

46

119

10

12

I-RTN-0

I-RTN-1

I-RTN-2

I-RTN-3

I-IN-0

I-IN-2

I-IN-3

I-IN-1

1

2

7

8

V-OUT-0

V-OUT-2

V-OUT-3

V-OUT-1

1756-IF6CIS

LOOP POWER SUPPLIED INTERNALLY

USER SUPPLIEDLOOP POWER SUPPLIED INTERNALLY

Black

Brown

Green

Yellow

White/Black

White/Red

Violet

Red

White/Yellow

White/Green

White/Brown

White/Violet

Black

Brown

Green

Yellow

White/Black

White/Red

Violet

Red

White/Yellow

White/Green

White/Violet

White/Brown

using these components (conversion module, cable and input module). Read and understand these considerations before installation.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 107

Page 108: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIV to 1756-IF8I — Current

DIR 10002306458 (Version 00)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

3

2

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

� � � � � � � � �

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425 � �

� � � � �

� � � � �

� � � � � �

� � � � � � � �

� � � � � � � � �

� � � � � � � � � � � �

� � � �

N/A

N/A

N/A

4N/A

N/A

N/A

� � � � � � �

� � � � �

� � � � � �

� � � � � � � �

� � � � � � � � �

� � � � � � � � � � � �

� � � �

1492-CONACAB020N38

CURRENT LOAD

-

CURRENT LOAD

+

-

24VDCSUPPLY

24VDCSUPPLY

+

1516

1819

2122

2425

29 RTN_7

2625

32

31

3433

2

1

98

1510

1716

23

7

24N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

35

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

27 IN_7/I/SRC

CABLE “B”

CABLE “A”

30 RTN_628 IN_6/I/SRC

21 RTN_519 IN_5/I/SRC

22 RTN_420 IN_4/I/SRC

13 RTN_311 IN_3/I/SRC

14 RTN_212 IN_2/I/SRC

5 RTN_13 IN_1/I/SRC

6 RTN_04 IN_0/I/SRC

18 N.C. 36 N.C.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals.

Interface Module 1771-RTP3

IMPORTANT

108 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 109: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIV to 1756-IF6I — Current

41171-074 (00)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

1771-RTP4

3

2

4

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

1756-IF6I5

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425 3

5

46

119

10

12

BlackWhite

Green

Orange

White/Black

White/Red

White/Orange

Gray

IN-0/I

IN-1/I

IN-2/I

IN-3/I

RTN-0

RTN-2

RTN-3

CABLE “B”

1 Cables are available in 2.0m, or 5.0m

2 Terminals starting with A are the lower row of terminals, B terminals are the upper row.

3 Follow your PLC Analog User Manual for propershield grounding instructions.

4 RTN terminals are internally connected on the 1756-IF6I.

5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only truefor modules RTP3. The Bul. 1492cable does not connect to these terminals.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

1756-IF6IN/A

N/A

N/A

4

N/A

N/A

N/A

RTN-1

1 IN-0/V

2 IN-1/V

7 IN-2/V

8 IN-3/V

35

46

119

10

12

BlackWhite

Green

Orange

White/Black

White/Red

White/Orange

Gray

1

2

7

8

1492-CONACAB010N3

CABLE “A”1492-CONACAB010N3

CURRENT LOAD

-

CURRENT LOAD

+

-24VDCSUPPLY

24VDCSUPPLY

+

1516

1819

2122

2425 IN-0/I

IN-1/I

IN-2/I

IN-3/I

RTN-0

RTN-2

RTN-3

RTN-1

IN-0/V

IN-1/V

IN-2/V

IN-3/V

using these components (conversion module, cable and input module). Read and understand these considerations before installation.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 109

Page 110: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIV to 1756-IF8I — Voltage

DIR 10002306478 (Version 00)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

3

2

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

� � � � � � � � �

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425 � � �

� � � � �

� � �

� �

� � � � � � � � �

� � � � � �

� � � � �

� � � � �

N/A

N/A

N/A

4 N/A

N/A

N/A

� � �� � � � �

� � �

� �

� � � � � � � � �

� � � � � �

� � � � �

� � � � �

1492-CONACAB020N78

VOLTAGE LOAD

VOLTAGE LOAD

+

-

1516

1819

2122

2425

29 RTN_7

2827

32

31

3433

4

3

118

1512

1916

23

7

24N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

35

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

25 IN_7/V

CABLE “B”

CABLE “A”

30 RTN_626 IN_6/V

21 RTN_517 IN_5/V

22 RTN_418 IN_4/V

13 RTN_39 IN_3/V

14 RTN_210 IN_2/V

5 RTN_11 IN_1/V

6 RTN_02 IN_0/V

20 N.C. 36 N.C.

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� for module RTP4. The Bul. 1492 cable does not connect to these terminals.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Interface Module1771-RTP4

IMPORTANT

110 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 111: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIV to 1756-IF6I — Voltage

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Cable “A”1492-CONACAB020N7

Cable “B”1492-CONACAB020N7

Interface Module 1771-RTP4 or 1771-RTP4

1756-IF6I

1756-IF6I

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1VOLTAGE LOAD

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425 1

5

26

117

8

12

VioletBlack

Green

Red

White/Black

White/Red

Yellow

Brown

IN-0V

IN-1V

IN-2V

IN-3V

RTN-0

RTN-2

RTN-3

N/A

N/A

N/A

N/A

N/A

N/A

+

-

RTN-1

15

26

117

8

12

VOLTAGE LOAD

+

-

IN-0V

IN-1V

IN-2V

IN-3V

RTN-0

RTN-2

RTN-3

RTN-1

1516

1918

2221

2425 Violet

Black

Green

Red

White/Black

White/Red

Yellow

Brown

Conversion Module Installation and Application Considerations Cables are available in 2.0m, or 5.0m

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

Follow your PLC Analog User Manual for proper shield grounding instructions.

RTN terminals are internally connected on the 1756-IF6I.

Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. 41171-080 Ver (00)

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 111

Page 112: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIV to 1756-IF6I — Current and Voltage

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Cable “B”1492-CONACAB020N7

Interface Module 1771-RTP4

1756-IF6I

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1CURRENT LOAD

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425 Violet

Black

Green

Red

White/Black

White/Red

Yellow

Brown

N/A

N/A

N/A

N/A

N/A

N/A

+

-

15

26

117

8

12

VOLTAGE LOAD

+

-

IN-0V

IN-1V

IN-2V

IN-3V

RTN-0

RTN-2

RTN-3

RTN-1

1516

1918

2221

2425 Violet

Black

Green

Red

White/Black

White/Red

Yellow

Brown

Conversion Module Installation and Application Considerations Cables are available in 2.0m, or 5.0m

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

Follow your PLC Analog User Manual for proper shield grounding instructions.

RTN terminals are internally connected on the 1756-IF6I.

Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. 41171-039 Ver (00)

3

4

35

46

119

10

12

BlackWhite

Green

Orange

White/Black

White/Red

White/Orange

Gray

IN-0/I

IN-1/I

IN-2/I

IN-3/I

RTN-0

RTN-2

RTN-3

1756-IF6I

RTN-1

1 IN-0/V

2 IN-1/V

7 IN-2/V

8 IN-3/V

CABLE “A”1492-CONACAB010N3

(Voltage)

(Current)

IMPORTANT

112 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 113: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIV to 1756-IF6I — Voltage and Current

41171-038 (00)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

1771-RTP4

3

2

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

5

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425 Black

White

Green

Orange

White/Black

White/Red

White/Orange

Gray

1 Cables are available in 2.0m, or 5.0m

2 Terminals starting with A are the lower row of terminals, B terminals are the upper row.

3 Follow your PLC Analog User Manual for propershield grounding instructions.

4 RTN terminals are internally connected on the 1756-IF6I.

5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only truefor modules RTP3. The Bul. 1492cable does not connect to these terminals.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

N/A

N/A

N/A

N/A

N/A

N/A

BlackWhite

Green

Orange

White/Black

White/Red

White/Orange

Gray

CABLE “A”1492-CONACAB010N7

Voltage LOAD

-

CURRENT LOAD

+

-

+

1516

1819

2122

2425

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

(Voltage)

CABLE “B”1492-CONACAB010N3

(Current)4

35

46

119

10

12

IN-0/I

IN-1/I

IN-2/I

IN-3/I

RTN-0

RTN-2

RTN-3

1756-IF6I

RTN-1

1 IN-0/V

2 IN-1/V

7 IN-2/V

8 IN-3/V

1756-IF6I

15

26

117

8

12

IN-0V

IN-1V

IN-2V

IN-3V

RTN-0

RTN-2

RTN-3

RTN-1

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 113

Page 114: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NR to 1756-IRT8I

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

3

2

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

� � � � � � � � �

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

2425 4

3

� � �

� � � � �

� � � � �� � � � � �

� � � � � � � � �

� � � � � � � � �

� � � �

1492-CONACAB020N48

N/A

N/A

N/A

13

N/A

N/A

N/A

RTD TRANSMITTER

6

� � � � � � � � � � � �

� � � � � �

� � � �

� � � � �

� � �

22

10

721

41819

1516

8

7

10

12

11

14

16

15

18

242513

22

10

721

41819

1516

RTD TRANSMITTER

2019

IN_4(-)/B

IN_4(+)/A

22 IN_4/RTD C

24

23

26

28

27

30

32

31

34

IN_5(-)/B

IN_5(+)/A

IN_5/RTD C

IN_6(-)/B

IN_6(+)/A

IN_6/RTD C

IN_7(-)/B

IN_7(+)/A

IN_7/RTD C

Cable “A”

Cable “B”

3533

36

2

1

139

2117

25

5

29N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C.

N.C. N.C.

N.C.

N.C.

� � �

� � � � �

� � � � �� � � � � �

� � � � � � � � �

� � � � � � � � �

� � � �

� � � � � � � � � � � �

� � � � � �

� � � �

� � � � �

� � �

IN_0(-)/B

IN_0(+)/A

IN_0/RTD C

IN_1(-)/B

IN_1(+)/A

IN_1/RTD C

IN_2(-)/B

IN_2(+)/A

IN_2/RTD C

IN_3(-)/B

IN_3(+)/A

IN_3/RTD C

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

DIR 10002306848 (Version 00)

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals.

4

Interface Module1771-RTP4

IMPORTANT

114 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 115: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NR to 1756-IR6I

41171-075 (00)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

1771-RTP4

3

2

4

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

1756-IR6I5

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

2425 3

1

Black

White

GreenOrange

White/Black

White/Red

Gray

IN-0/B

IN-0/A

1492-CONACAB020N4

1 Cables are available in 2.0m, or 5.0m

2 Terminals starting with A are the lower row of terminals, B terminals are the upper row.

3 Follow your PLC Analog User Manual for propershield grounding instructions.

4 RTN terminals are internally connected on the 1756-IR6I.

5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only truefor modules RTP4. The Bul. 1492cable does not connect to these terminals.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

1756-IR6IN/A

N/A

N/A

13

N/A

N/A

N/A

RTD TRANSMITTER

5 RTN-0

White/Orange

Violet

Brown

Yellow

Red

22

10

721

41819

1516

4

2

6

9

7

11

10

8

12

IN-1/B

IN-1/A

RTN-1

IN-2/B

IN-2/A

RTN-2

IN-3/B

IN-3/A

RTN-3

4

242513

22

10

721

41819

1516

RTD TRANSMITTER

1492-CONACAB020N4

31

IN-0/B

IN-0/A

5 RTN-0

4

2

6

9

7

11

10

8

12

IN-1/B

IN-1/A

RTN-1

IN-2/B

IN-2/A

RTN-2

IN-3/B

IN-3/A

RTN-3

Cable “A”

Cable “B”

Black

White

GreenOrange

White/Black

White/Red

Gray

White/Orange

Violet

Brown

Yellow

Red

There are several key application considerations and system specifications (bottomusing these components (conversion module, cable and input module). Read andconsiderations before installation.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 115

Page 116: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NT1 or -NT2 to 1756-IRT8I

DIR 10002306849 (Version 00)

B1A1B2B3A2A3B4B5A4A5

B6B7A6A7B8B9A9A8

3

2W1SH

I4

I3

I2

I1

R4

R3

R2

R1

1756-IRT8I4

O4

O3

O2

O1

S4

S3

S2

S1

1492-CONACAB020N68

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

1920

2423

2728

3132

IN_4(-)/B

IN_5(-)/B

IN_6(-)/B

IN_7(-)/B

IN_4(+)/A

IN_6(+)/A

IN_7(+)/A

IN_5(+)/A

CJC1

CJC1Thermocouple

35

36

Cable “B”

B1A1B2B3A2A3B4B5A4A5

B6B7A6A7B8B9A9A8

2W1SH

I4

I3

I2

I1

R4

R3

R2

R1

4

O4

O3

O2

O1

S4

S3

S2

S1

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

34

87

1112

1516

Thermocouple1

2

Cable “A”

3

1

White/Violet

White/Grey

White/Violet

White/Grey

2522

26

6

5

1310

1714

18

9

21N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.N.C.

N.C. N.C.N.C.N.C.

2930

N.C.N.C.

14

1

IN_0(-)/B

IN_1(-)/B

IN_2(-)/B

IN_3(-)/B

IN_0(+)/A

IN_2(+)/A

IN_3(+)/A

IN_1(+)/A

CJC0

CJC0

14

1

3334

N.C.N.C.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals.

This conversion solution requires replacement of the exisiting (1) 1771-RTP1 interface module with (2) 1771-RT41 interface modules. Each 1771-RTP1 and RT41 module has there own cold junction compensation thermocouple attached to the interface module.

1771-RT41

Interface Module

1771-RT41Interface Module

IMPORTANT

116 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 117: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NT1 to 1756-IT6I

41171-076 (01)

B1A1B2B3A2A3B4B5A4A5

B6B7A6A7B8B9A9A8

1771-RT41

3

2W1SH

I4

I3

I2

I1

R4

R3

R2

R1

1756-IT6I4

O4

O3

O2

O1

S4

S3

S2

S1

1492-CONACAB020N5

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

15

62

711

812

RTN-0

RTN-1

RTN-2

RTN-3

IN-0

IN-2

IN-3

IN-1

Cables are available in 2.0M or 5.0M.Terminals starting with A are the lower row of

terminals, B terminals are the upper row.Follow your PLC Analog User Manual for proper

shield grounding instructions.Terminals W1, W2 and W3 are spares used for field wire

convenience. NOTE. This is only true for modules RT41 . The Bul. 1492 cable does not connect to these terminals.

CJC+

CJC-Thermocouple

10

14

Cable “B”

B1A1B2B3A2A3B4B5A4A5

B6B7A6A7B8B9A9A8

1771-RT41

2W1SH

I4

I3

I2

I1

R4

R3

R2

R1

1756-IT6I4

O4

O3

O2

O1

S4

S3

S2

S1

1492-CONACAB020N5

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

15

62

711

812

RTN-0

RTN-1

RTN-2

RTN-3

IN-0

IN-2

IN-3

IN-1

CJC+

CJC-Thermocouple

10

14

Cable “A”

3

1

1

White/Violet

White/Grey

White/Violet

White/Grey

There are several key application considerations and system specifications (bottomusing these components (conversion module, cable and input module). Read andconsiderations before installation.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 117

Page 118: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NOV to 1756-OF8I

DIR 10002306686 (Version 00)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

3

2

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

� � � � � � � �

VOLTAGE LOAD

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

15

418

721

1024

13

6

2

15

418

721

1024

13

1

14

10

9

� � �

� � � � �

� � � � �� � � � � �

� � � � � � � � �

� � � � � � � � �

� � � � � � � � � � � �

� � � �

� � �

� � � � �

� � � � �� � � � � �

� � � � � � � � �

� � � � � � � � �

� � � � � � � � � � � �

� � � �

OUT_0/V

OUT_1/V

OUT_2/V

OUT_3/V

RTN_0

RTN_2

1492-CONACAB020N18

22

18

17

30

26

25

OUT_4/V

OUT_5/V

OUT_6/V

OUT_7/V

RTN_4

RTN_6

Cable”A”

Cable”B”

2524

31

26

3332

1

87

109

1615

2

23N.C.

N.C.N.C.N.C.N.C.N.C.N.C.

N.C.N.C.

34

N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.

18

17 3536

N.C.N.C.

N.C.N.C.

21 RTN_5

29 RTN_7

13 RTN_3

5 RTN_1

-

+

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Interface Module1771-RTP3 or 1771-RTP4

IMPORTANT

118 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 119: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NOV to 1756-OF6VI

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1756-OF6VI

1756-OF6VI Cable “A”1492-CONACAB020N1

Cable “B”1492-CONACAB020N1

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

Interface Module 1771-RTP3 or RTP4

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1VOLTAGE LOAD

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

15

418

721

1024 5

1

2

6

11

7

8

12

Black

White

Green

Orange

White/Black

White/Red

White/Orange

Gray

Black

White

Green

Orange

White/Black

White/Red

White/Orange

Gray

OUT-0

OUT-1

OUT-2

OUT-3

RTN-0

RTN-1

RTN-2

RTN-3

N/A

N/A

N/A

13

5

1

2

6

11

7

8

12

N/A

N/A

N/A

+

-

OUT-0

OUT-1

OUT-2

OUT-3

RTN-0

RTN-1

RTN-2

RTN-315

418

721

1024

13

Conversion Module Installation and Application Considerations Cables are available in 2.0m, or 5.0m

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

Follow your PLC Analog User Manual for proper shield grounding instructions.

RTN terminals are internally connected on the 1756-OF6VI.

Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for modules RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. 41171-081 Ver(00)

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 119

Page 120: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIV1 to 1756-IF8I

DIR 10002306486 (Version 00)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

3

2

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

� � � � � � � � �

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425 � � �

� � � � �

� � �

� �

� � � � � � � � �

� � � � � �

� � � � �

� � � � �

N/A

N/A

N/A

4 N/A

N/A

N/A

� � �� � � � �

� � �

� �

� � � � � � � � �

� � � � � �

� � � � �

� � � � �

1492-CONACAB020N78

VOLTAGE LOAD

VOLTAGE LOAD

-

+

1516

1819

2122

2425

29 RTN_7

2827

32

31

3433

4

3

118

1512

1916

23

7

24N.C.N.C.

N.C.N.C.N.C.N.C.N.C.N.C.

N.C.N.C.

N.C.

35

N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.

25 IN_7/V

CABLE “B”

CABLE “A”

30 RTN_626 IN_6/V

21 RTN_517 IN_5/V

22 RTN_418 IN_4/V

13 RTN_39 IN_3/V

14 RTN_210 IN_2/V

5 RTN_11 IN_1/V

6 RTN_02 IN_0/V

20 N.C. 36 N.C.

-

+

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals.

Interface Module 1771-RTP4

IMPORTANT

120 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 121: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIV1 to 1756-IF6I

41171-078 (00)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

RTP4

3

2

4

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

1756-IF6I

VOLTAGE LOAD

5

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1918

2221

2425 1

5

62

713

8

12

VioletBlack

Green

Red

White/Black

White/Red

Yellow

Brown

IN-0V

IN-1V

IN-2V

IN-3V

RTN-0

RTN-2

RTN-3

1 Cables are available in 2.0m, or 5.0m

2 Terminals starting with A are the lower row of terminals, B terminals are the upper row.

3 Follow your PLC Analog User Manual for propershield grounding instructions.

4 RTN terminals are internally connected on the 1756-IF6I.

5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only truefor modules RTP3 and RTP4. The Bul. 1492cable does not connect to these terminals.

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

1756-IF6IN/A

N/A

N/A

4

N/A

N/A

N/A

+

-

RTN-1

15

62

713

8

12

VOLTAGE LOAD

+

-

IN-0V

IN-1V

IN-2V

IN-3V

RTN-0

RTN-2

RTN-3

RTN-1

VioletBlack

Green

Red

White/Black

White/Red

Yellow

Brown

1516

1918

2221

2425

1492-CONACAB020N7

1492-CONACAB020N7

Cable”B”

Cable”A”

of drawing) when understand these

There are several key application considerations and system specifications (bottomusing these components (conversion module, cable and input module). Read andconsiderations before installation.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 121

Page 122: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NT2 to 1756-IRT8I

DIR 10002306849 (Version 00)

B1A1B2B3A2A3B4B5A4A5

B6B7A6A7B8B9A9A8

3

2W1SH

I4

I3

I2

I1

R4

R3

R2

R1

1756-IRT8I4

O4

O3

O2

O1

S4

S3

S2

S1

1492-CONACAB020N68

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

1920

2423

2728

3132

IN_4(-)/B

IN_5(-)/B

IN_6(-)/B

IN_7(-)/B

IN_4(+)/A

IN_6(+)/A

IN_7(+)/A

IN_5(+)/A

CJC1

CJC1Thermocouple

35

36

Cable “B”

B1A1B2B3A2A3B4B5A4A5

B6B7A6A7B8B9A9A8

2W1SH

I4

I3

I2

I1

R4

R3

R2

R1

4

O4

O3

O2

O1

S4

S3

S2

S1

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

34

87

1112

1516

Thermocouple1

2

Cable “A”

3

1

White/Violet

White/Grey

White/Violet

White/Grey

2522

26

6

5

1310

1714

18

9

21N.C.N.C.

N.C.N.C.N.C.N.C.

N.C.N.C.

N.C. N.C.N.C.N.C.

2930

N.C.N.C.

14

1

IN_0(-)/B

IN_1(-)/B

IN_2(-)/B

IN_3(-)/B

IN_0(+)/A

IN_2(+)/A

IN_3(+)/A

IN_1(+)/A

CJC0

CJC0

14

1

3334

N.C.N.C.

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals.

This conversion solution requires replacement of the exisiting (1) 1771-RTP1 interface module with (2) 1771-RT41 interface modules. Each 1771-RTP1 and RT41 module has there own cold junction compensation thermocouple attached to the interface module.

1771-RT41

Interface Module

1771-RT41Interface Module

IMPORTANT

122 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 123: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NT2 to 1756-IT6I2

41171-077 (01)

B1A1B2B3A2A3B4B5A4A5

B6B7A6A7B8B9A9A8

1771-RT41

3

2W1SH

I4

I3

I2

I1

R4

R3

R2

R1

1756-IT6I24

O4

O3

O2

O1

S4

S3

S2

S1

1492-CONACAB020N6

CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

56

87

910

1112

RTN-0

RTN-1

RTN-2

RTN-3

IN-0

IN-2

IN-3

IN-1

Cables are available in 2.0M or 5.0M.Terminals starting with A are the lower row of

terminals, B terminals are the upper row.Follow your PLC Analog User Manual for proper

shield grounding instructions.Terminals W1, W2 and W3 are spares used for field wire

convenience. NOTE. This is only true for modules RT41 . The Bul. 1492 cable does not connect to these terminals.

CJC+

CJC-Thermocouple

3

4

Cable “B”

B1A1B2B3A2A3B4B5A4A5

B6B7A6A7B8B9A9A8

1771-RT41

2W1SH

I4

I3

I2

I1

R4

R3

R2

R1

1756-IT6I24

O4

O3

O2

O1

S4

S3

S2

S1

1492-CONACAB020N6

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

56

87

910

1112

RTN-0

RTN-1

RTN-2

RTN-3

IN-0

IN-2

IN-3

IN-1

CJC+

CJC-Thermocouple

3

4

Cable “A”

3

1

1

White/Violet

White/Grey

White/Violet

White/Grey

of drawing) when understand these

There are several key application considerations and system specifications (bottomusing these components (conversion module, cable and input module). Read andconsiderations before installation.

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 123

Page 124: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

Combination High Resolution I/O

1771-NIVR to1756-IRT8I and -IF8I

using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1492-CONACAB020N74

1492-CONACAB020N44

Interface Module1771-RTP4

1756-IF8I

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1VOLTAGE LOAD

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425 2

6

15

1410

9

13

� � � � � �

� � �

� � � �

� � �

� � � � � � � � �

� � � � � � � � �

� � � � � �

� � � �

IN_0/V

IN_1/V

IN_2/V

IN_3/V

RTN_0

RTN_2

RTN_3

N/A

N/A

N/A

N/A

N/A

N/A

+

-

RTN_1

� 1756-IRT8I

242513

22

10

721

41819

1516

RTD ANSMITTER

43

IN_0(-)/BIN_0(+)/A

6 IN_0/RTD C

8

7

10

12

11

14

16

15

18

IN_1(-)/B

IN_1(+)/A

IN_1/RTD C

IN_2(-)/B

IN_2(+)/A

IN_2/RTD C

IN_3(-)/B

IN_3(+)/A

IN_3/RTD C� � � � � � � � �

� � �

� � � � �

� � � �

� � � � � �

� � � � � � � � � � �

� � � � � � � � �

� � � �

� � � �

� � �

� � � � � �

� � � � �

CABLE “B”

CABLE “A”

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals.

DIR 10002306496(Version 00)

IMPORTANT

124 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 125: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIVR to 1756-IR6Iand -IF6I

Conversion Module Installation and Application Considerations Cables are available in 2.0m, or 5.0m

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

Follow your PLC Analog User Manual for proper shield grounding instructions.

RTN terminals are internally connected on the 1756-IF6I.

Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. [Reference Doc: 41171-082 (Version 00)]

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Cable “A”1492-CONACAB020N7

Cable “B”1492-CONACAB020N4

Interface Module 1771-RTP4

1756-IF6I

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1VOLTAGE LOAD

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425 1

5

26

117

8

12

VioletBlack

Green

Red

White/Black

White/Red

Yellow

Brown

IN-0V

IN-1V

IN-2V

IN-3V

RTN-0

RTN-2

RTN-3

N/A

N/A

N/A

N/A

N/A

N/A

+

-

RTN-1

1756-IR6I

242513

22

10

721

41819

1516

RTD TRANSMITTER

31

IN-0/BIN-0/A

5 RTN-0

4

2

6

9

7

11

10

8

12

IN-1/B

IN-1/A

RTN-1

IN-2/B

IN-2/A

RTN-2

IN-3/B

IN-3/A

RTN-3

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 125

Page 126: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIVR to 1756-IRT8I and -IF8I

using these components (conversion module, cable and input module). Read and understand these considerations before installation.

1492-CONACAB020N34

1492-CONACAB020N44

Interface Module1771-RTP4

1756-IF8I

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1CURRENT LOAD

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1516

1819

2122

2425 4

6

35

1412

11

13

� � � � �

� � �

� �

� � � �

� � � � � � � � �

� � � � � �

� � � � � � � �

� � � �

IN_0/I/SRC

IN_1/I/SRC

IN_2/I/SRC

IN_3/I/SRC

RTN_0

RTN_2

RTN_3

N/A

N/A

N/A

N/A

N/A

N/A

+

-

RTN_1

� 1756-IRT8I

242513

22

10

721

41819

1516

RTD TRANSMITTER

43

IN_0(-)/BIN_0(+)/A

6 IN_0/RTD C

8

7

10

12

11

14

16

15

18

IN_1(-)/B

IN_1(+)/A

IN_1/RTD C

IN_2(-)/B

IN_2(+)/A

IN_2/RTD C

IN_3(-)/B

IN_3(+)/A

IN_3/RTD C� � � � � �

� �

� � � �

� �

� � � � �

� � � � � � � �

� � � � � � � � �

� � � �

� � � �

� � � � �

� � � �

� � �

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals.

DIR 10002306490 (Version 00)

CABLE “B”

CABLE “A”

IMPORTANT

126 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 127: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIVR to 1756-IR6I and -IF6I

Conversion Module Installation and Application Considerations Cables are available in 2.0m, or 5.0m

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

Follow your PLC Analog User Manual for proper shield grounding instructions.

RTN terminals are internally connected on the 1756-IF6I.

Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. [Reference Doc: 41171-083 (Version 00)]

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Cable “B”1492-CONACAB020N4

Interface Module 1771-RTP4

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1VOLTAGE LOAD

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

N/A

N/A

N/A

N/A

N/A

N/A

+

-

1756-IR6I

242513

22

10

721

41819

1516

RTD TRANSMITTER

31

IN-0/BIN-0/A

5 RTN-0

4

2

6

9

7

11

10

8

12

IN-1/B

IN-1/A

RTN-1

IN-2/B

IN-2/A

RTN-2

IN-3/B

IN-3/A

RTN-3

Cable “A”1492-CONACAB010N3

1756-IF6I

1516

1819

2122

2425 3

5

46

119

10

12

BlackWhite

Green

Orange

White/Black

White/Red

White/Orange

Gray

IN-0/I

IN-1/I

IN-2/I

IN-3/I

RTN-0

RTN-2

RTN-3

RTN-1

1 IN-0/V

2 IN-1/V

7 IN-2/V

8 IN-3/V

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 127

Page 128: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIVT to 1756-IRT8I and -IF8I

using these components (conversion module, cable and input module). Read and understand these considerations before installation.

DIR 10002306594 (Version 00)

26

15

1410

9

13

IN_0/V

IN_1/V

IN_2/V

IN_3/V

RTN_0

RTN_2

RTN_3

RTN_1

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

3

2W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

1756-IRT8I4

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1492-CONACAB020N54

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

34

87

1112

1516

IN_0(-)/B

IN_1(-)/B

IN_2(-)/B

IN_3(-)/B

IN_0(+)/A

IN_2(+)/A

IN_3(+)/A

IN_1(+)/A

CJC+CJC-

Thermocouple

1492-CONACAB020N74

1516

1819

2122

2425

� � � � � �

� � �

� � � �

� � �

� � � � � � � � �

� � � � � � � � �

� � � � � �

� � � �

VOLTAGE LOAD

+

-

Interface Module1771-RTP1

10

1414

1

1756-IF8I

Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M)

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals.

CABLE “B”

CABLE “A”

IMPORTANT

128 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 129: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIVT to 1756-IT6I and -IF6I

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

3

2W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

1756-IT6I4

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

CABLE “B”

1492-CONACAB010N5CABLE “B”

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

56

87

910

1112

RTN-0

RTN-1

RTN-2

RTN-3

IN-0

IN-2

IN-3

IN-1

CJC+CJC-

Thermocouple

Cable “A”1492-CONACAB020N7

1756-IF6I

1516

1819

2122

2425 1

5

26

117

8

12

VioletBlack

Green

Red

White/Black

White/Red

Yellow

Brown

IN-0V

IN-1V

IN-2V

IN-3V

RTN-0

RTN-2

RTN-3

RTN-1

VOLTAGE LOAD

+

-

Conversion Module Installation and Application Considerations Cables are available in 2.0m, or 5.0m

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

Follow your PLC Analog User Manual for proper shield grounding instructions.

RTN terminals are internally connected on the 1756-IF6I.

Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. [Reference Doc: 41171-084 (Version 00)]

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Interface Module 1771-RTP1

10

1414

1

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 129

Page 130: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIVT to 1756-IRT8I and -IF8I

Interface Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-IF8I (or 1756-IRT8I). Recommended cable lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M). See table 2 for other lengths.

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

� Follow your PLC Analog User Manual for proper shield grounding instructions.

� for module RTP4. The Bul. 1492 cable does not connect to these terminals.

DIR 10002306504 (Version 00)

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

3

2W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

1756-IRT8I4

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

1492-CONACAB020N54

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

34

87

1112

1516

IN_0(-)/B

IN_1(-)/B

IN_2(-)/B

IN_3(-)/B

IN_0(+)/A

IN_2(+)/A

IN_3(+)/A

IN_1(+)/A

CJC+CJC-

Thermocouple

1492-CONACAB020N34

1516

1819

2122

2425CURRENT

LOAD+

-

Interface Module1771-RTP1

10

1414

1

1756-IF8I

46

35

1412

11

13

IN_0/I/SRC

IN_1/I/SRC

IN_2/I/SRC

IN_3/I/SRC

RTN_0

RTN_2

RTN_3

RTN_1

� � � � �

� � �

� �

� � � �

� � � � � � � � �

� � � � � �

� � � � � � � �

� � � �

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

CABLE “B”

CABLE “A”

IMPORTANT

130 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016

Page 131: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Wiring Diagrams - High Resolution Isolated Analog

1771-NIVT to 1756-IT6I and -IF6I

B1B2B3B4B5A4A5B8B9A6A7B12B13A8A9B16B17A10A11

2W2SH

W3

I8

I7

I6

I5

I4

I3

I1

I2

R8

R7

R6

R5

R4

R3

R2

R1

1756-IT6I4

A1A2A3B12B13A12A13B14B15A14A15B16B17A16A17B18B19

A18A19

CRW1

CL

O8

O7

O6

O5

O4

O3

O1

O2

S8

S7

S6

S5

S4

S3

S2

S1

CABLE “B”

1492-CONACAB010N5CABLE “B”

1516

1918

2524

2122

+

-

Black

Red

Green

Brown

White/Black

White/Red

Yellow

Violet

THERMOCOUPLE

15

62

711

812

RTN-0

RTN-1

RTN-2

RTN-3

IN-0

IN-2

IN-3

IN-1

CJC+CJC-

Thermocouple

CURRENT LOAD

+

-

Conversion Module Installation and Application Considerations Cables are available in 2.0m, or 5.0m

Terminals starting with A are the lower row of terminals, B terminals are the upper row.

Follow your PLC Analog User Manual for proper shield grounding instructions.

RTN terminals are internally connected on the 1756-IF6I.

Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. 41171-085 Ver (00)

There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation.

Interface Module 1771-RTP1

N/A

N/A

N/A

1756-IF6I

1516

1819

2122

2425 3

5

46

119

10

12

BlackWhite

Green

Orange

White/Black

White/Red

White/Orange

Gray

IN-0/I

IN-1/I

IN-2/I

IN-3/I

RTN-0

RTN-2

RTN-3

RTN-1

1 IN-0/V

2 IN-1/V

7 IN-2/V

8 IN-3/V

10

1414

1

1492-CONACAB010N3CABLE “A”

IMPORTANT

Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 131

Page 132: I/O Wiring Conversion Systems, PLC-5 1771 to ControlLogix 1756 · 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 I/O Wiring Conversion Systems What’s Inside Summary

Publication 1492-SG121E-EN-P - July 2016Supersedes Publication 1492-SG121D-EN-P - October 2014 Copyright © 2016 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Rockwell Automation SupportUse the following resources to access support information.

Documentation FeedbackYour comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.

Technical Support Center Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates.

www.rockwellautomation.com/knowledgebase

Local Technical Support Phone Numbers Locate the phone number for your country. www.rockwellautomation.com/global/support/get-support-now.page

Direct Dial Codes Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer.

www.rockwellautomation.com/global/support/direct-dial.page

Literature Library Installation Instructions, Manuals, Brochures, and Technical Data.

www.rockwellautomation.com/literature

Product Compatibility and Download Center (PCDC)

Get help determining how products interact, check features and capabilities, and find associated firmware.

www.rockwellautomation.com/global/support/pcdc.page

Allen-Bradley, ControlLogix, LISTEN. THINK. SOLVE, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc.Trademarks not belonging to Rockwell Automation are property of their respective companies.

Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.