integrated lights out manager 2 - fujitsu global 和 cmm 上的 ilom 2 ilom 介面 3 ilom...

274
Integrated Lights Out Manager 2.0 使用者指南 手冊編號:C120-E474-01ZT 設備編號:875-4290-10 2007 10 月,修正版本 A

Upload: doandieu

Post on 29-Apr-2018

243 views

Category:

Documents


2 download

TRANSCRIPT

  • Integrated Lights Out Manager 2.0

    C120-E474-01ZT875-4290-102007 10 A

  • Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A.

    Sun Microsystems, Inc. http://www.sun.com/patents /

    Sun ()

    Sun

    Berkeley BSD UNIX / X/Open Company, Ltd.

    SunSun MicrosystemsSun Javadocs.sun.com Solaris Sun Microsystems, Inc. /

    SPARC SPARC International, Inc. / SPARC Sun Microsystems, Inc.

    OPEN LOOK Sun Graphical User Interface (Sun ) Sun Microsystems,Inc. Sun Xerox Sun Xerox Xerox OPEN LOOK GUI Sun Sun

    Sun Microsystems, Inc. FAR

  • xv

    1. ILOM 1

    ILOM 2

    SP CMM ILOM 2

    ILOM 3

    ILOM 3

    ILOM 4

    ILOM 5

    ILOM 5

    ILOM 6

    ILOM 2.0 7

    2. ILOM 9

    ILOM 10

    10

    DHCP IP 11

    DHCPDISCOVER 12

    DHCP 12

    SP MAC 12

    iii

  • DHCP IP 13

    IP 13

    IP 14

    14

    IP 15

    IP 15

    ILOM 15

    SP CMM 17

    17

    IP SP 18

    DHCP IP 18

    IP SP 20

    IP CMM 22

    IP 23

    Web ILOM IP 23

    CLI ILOM IP 25

    27

    Web 27

    CLI 29

    3. ILOM 31

    CLI 32

    CLI 32

    CLI 34

    CLI 34

    35

    35

    35

    36

    iv Integrated Lights Out Manager 2.0 2007 10 A

  • 36

    36

    CLI ILOM 37

    ILOM 37

    ILOM 37

    4. ILOM Web 39

    Web 39

    40

    Web 41

    42

    [System Information] 42

    [Versions] 43

    [Session Time-Out] 43

    [Components] 43

    [Identification Information] 43

    [System Monitoring] 43

    [Sensor Readings] 44

    [Indicators] 44

    [Event Logs] 44

    [Configuration] 44

    [System Management Access] 45

    [Alert Management] 45

    [Network] 45

    [Serial Port] 46

    [Clock Settings] 46

    [Syslog] 46

    [SMTP Client] 46

    [User Management] 46

    v

  • [User Accounts] 47

    [Active Sessions] 47

    [LDAP] 47

    [RADIUS] 47

    [Active Directory] 47

    [Remote Control] 48

    [Redirection] 48

    [Remote Power Control] 48

    [Mouse Mode Settings] 48

    [Maintenance] 49

    [Firmware Upgrade] 49

    [Reset SP] 49

    Web ILOM 50

    ILOM 50

    SSL 53

    54

    ILOM 55

    5. 57

    59

    59

    ILOM 60

    Web ILOM Root 60

    CLI ILOM Root 63

    63

    CLI 63

    Web 64

    CLI 65

    CLI 65

    vi Integrated Lights Out Manager 2.0 2007 10 A

  • CLI 65

    CLI 65

    CLI 66

    CLI 66

    CLI 67

    67

    CLI 68

    CLI 68

    Web 69

    Web 69

    Web 72

    Web 75

    Web 76

    Active Directory 77

    Active Directory 77

    Active Directory 78

    Web Active Directory 78

    Active Directory 79

    Active Directory 80

    Active Directory 81

    Web Active Directory 82

    83

    Active Directory 84

    CLI Active Directory 84

    CLI getcertfile 84

    CLI strictcertmode 85

    CLI certfilestatus 85

    Web Active Directory 86

    vii

  • Web 86

    Web 87

    Web 87

    87

    LDAP 87

    LDAP 88

    LDAP 89

    LDAP 90

    LDAP 91

    CLI ILOM LDAP 92

    Web ILOM LDAP 93

    RADIUS 94

    RADIUS 94

    RADIUS 94

    RADIUS 95

    CLI RADIUS 95

    Web RADIUS 95

    RADIUS 96

    show /SP/clients/radius 96

    set /SP/clients/radius 97

    show /SP/clients 98

    6. 101

    102

    CLI 102

    Web 103

    104

    104

    CLI 105

    viii Integrated Lights Out Manager 2.0 2007 10 A

  • CLI 105

    CLI 106

    Web 106

    Web 107

    107

    CLI 107

    Web 107

    108

    CLI 108

    Web 109

    7. 111

    112

    112

    Web 113

    CLI 114

    116

    116

    Web 117

    CLI 117

    ILOM 118

    ILOM 119

    119

    Web 119

    CLI 120

    120

    121

    Web 121

    CLI 123

    ix

  • ILOM 123

    Web 123

    Web 124

    Web ILOM 125

    CLI ILOM 126

    Web 128

    Web IP 129

    CLI IP 130

    131

    131

    132

    ILOM Web 134

    135

    Web 135

    Web 136

    Web 136

    ILOM CLI 137

    CLI 137

    139

    CLI 140

    CLI 141

    CLI 141

    SMTP 142

    Web SMTP 143

    CLI SMTP 143

    8. ILOM 145

    CLI ILOM 146

    146

    x Integrated Lights Out Manager 2.0 2007 10 A

  • CLI 146

    CLI 146

    147

    147

    CLI 148

    CLI 149

    149

    CLI HTTP HTTPS Web 150

    150

    Shell 151

    CLI 151

    CLI 152

    CLI SSH 153

    Web SSH 153

    CLI 154

    Web 155

    CLI SSH 155

    Web SSH 155

    Web ILOM 156

    Web 156

    Web 156

    Web 158

    Web 159

    Web HTTP HTTPS Web 159

    9. 161

    IPMI 161

    ILOM IPMI 162

    IPMItool 162

    xi

  • IPMI 163

    IPMItool 164

    164

    165

    165

    165

    166

    166

    FRU 166

    IPMI 168

    10. 169

    SNMP 170

    SNMP 170

    SNMP 171

    SNMP 171

    CLI SNMP 172

    CLI SNMP 172

    CLI SNMP 172

    CLI SNMP 173

    CLI SNMP 173

    CLI SNMP 173

    174

    CLI SNMP 175

    Web SNMP 176

    Web SNMP 176

    Web SNMP 178

    Web SNMP 179

    Web SNMP 180

    xii Integrated Lights Out Manager 2.0 2007 10 A

  • Web SNMP 180

    Web SNMP 181

    SNMP 181

    SNMP 182

    snmpget snmpwalk net-snmp 184

    snmpset 185

    snmptrapd 185

    11. ILOM 187

    187

    ILOM 188

    CLI ILOM 188

    CLI ILOM 189

    Web ILOM 189

    Web ILOM 190

    ILOM SP 191

    12. ILOM x64 193

    ILOM 194

    194

    196

    197

    197

    ILOM 198

    ILOM Web 198

    Web ILOM 199

    x64 ILOM 202

    ILOM Web ILOM 202

    204

    xiii

  • 204

    205

    205

    206

    ILOM 207

    CD 208

    A. ILOM 209

    CLI 209

    CLI 214

    cd 214

    create 215

    delete 216

    exit 216

    help 217

    load 218

    reset 219

    set 220

    show 224

    start 229

    stop 229

    version 230

    B. 231

    247

    xiv Integrated Lights Out Manager 2.0 2007 10 A

  • Integrated Lights Out Manager 2.0 ILOM ILOM ILOM ILOM ILOM

    ILOM ""ILOMFujitsuILOM ILOM

    ILOMILOM ILOM

    xv

  • CHAPTER 1 Introduction to ILOM

    ILOM CHAPTER 2 Establish Initial Communication With ILOM

    ILOM

    CHAPTER 3 ILOM Command-Line Interface and Log In

    ILOM command-line interfaceCLI CLI ILOM

    CHAPTER 4 ILOM Web Interface and Log In

    ILOM ILOM CHAPTER 5 Manage User Accounts

    ILOM CLI Active DirectoryLDAP RADIUS

    CHAPTER 6 Inventory and Component Management

    CHAPTER 7 System Monitoring and Alert Management

    CHAPTER 8 Configure ILOM Communication Settings

    ILOM ILOM CLI

    CHAPTER 9 Intelligent Platform Management Interface

    Intelligent Platform Management InterfaceIPMItool

    CHAPTER 10 Simple Network Management Protocol

    SNMP ILOM CLI SNMP

    xvi Integrated Lights Out Manager 2.0 2007 10 A

  • CHAPTER 11 Update ILOM Firmware

    ILOM CLI ILOM CHAPTER 12 Remote Management of x64 Servers Using the ILOM Remote Console

    ILOM ILOM Remote Console

    APPENDIX A ILOM Command-Line Interface Reference

    ILOM CLI APPENDIX B Glossary

    Index

    xvii

  • SPARC Enterprise

    http://www.fujitsu.com/sparcenterprise/manual/

    http://primeserver.fujitsu.com/sparcenterprise/manual/

    UNIX UNIX ()

    Solaris http://docs.sun.com

    Integrated Lights Out Manager 2.0 ( SPARC Enterprise T5120 T5220 )

    Integrated Lights Out Manager ILOM

    C120-E465

    xviii Integrated Lights Out Manager 2.0 2007 10 A

    http://www.fujitsu.com/sparcenterprise/manual/http://www.fujitsu.com/sparcenterprise/manual/http://docs.sun.com

  • *

    Fujitsu Welcomes Your CommentsWe would appreciate your comments and suggestions to improve this document.You can submit your comments by using "Reader's Comment Form".

    *

    AaBbCc123

    .login ls -a % You have mail.

    AaBbCc123

    % su

    Password:

    AaBbCc123

    6

    class rm filename

    xix

  • xx Integrated Lights Out Manager 2.0 2007 10 A

  • FOLD AND TAPE

    FOLD AND TAPE

    BUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO 741 SUNNYVALE CA

    NO POSTAGE

    NECESSARY

    IF MAILED

    IN THE

    UNITED STATES

    POSTAGE WILL BE PAID BY ADDRESSEE

    FUJITSU COMPUTER SYSTEMSAT TENTION ENGINEERING OPS M/S 2491250 EAST ARQUES AVENUEP O BOX 3470SUNNYVALE CA 94088-3470

    xxi

  • xxii Integrated Lights Out Manager 2.0 2007 10 A

  • 1

    ILOM

    Integrated Lights Out Manager (ILOM) 2.0

    2 ILOM 2 SP CMM ILOM 3 ILOM 3 ILOM 4 ILOM 5 ILOM 5 ILOM 6 ILOM 7 ILOM 2.0 8

    1

  • ILOM Integrated Lights Out Manager (ILOM) ILOM ILOMILOM Web SNMP IPMI ILOM ILOM (lights-out)

    ILOM

    ( Sun N1 System Manager ) (SP) BIOS

    SP CMM ILOM ILOMILOM (SP) (CMM) ()

    ILOM SP CMM () SP SP

    ()

    CMM CMM SP

    2 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM ILOM Web Web SP

    IPMI ILOM Web 4 (CLI) ILOM

    CLI DMTF SMASH CLP PC Shell (SSH) CLI 3

    ILOM CD 12

    (IPMI) IPMI v1.5 v2.0 IPMItool CLI (BMC) IPMItool IPMI 9

    (SNMP) ILOM (Sun N1 System Manager) (Hewlett-Packard OpenView IBM Tivoli) SNMP v3.0 ( SNMP v1 SNMP v2c) SNMP 10

    ILOM ILOM ILOM ILOM ILOM

    CMM SP

    ILOM IPMI Web SNMP PC ILOM

    1 ILOM 3

  • ILOM ILOM

    ILOM

    ILOM 10 Shell (SSH) Web

    ILOM Web CLI CMM SP IP CMM SP IP SP CMM IP 2

    1-1 ILOM

    CLI Web

    ILOM IP Web

    CLI

    CMM

    CLI CMM

    4 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM ILOM ILOM ILOM Web CLI ILOM ILOM ILOM

    ILOM ILOM root

    changeme

    (changeme) ( root) ILOM ()

    SP CMM ILOM root changeme ILOM ILOM root changeme SP CMM ILOM root 191 ILOM SP

    1 ILOM 5

  • ILOM 1-2 ILOM ILOM

    1-2 ILOM

    Web

    CLI DMTF SMASHCLP

    SNMP v1v2cv3 IPMI v1.5 v2.0 MIB IPMI SNMP MIB ILOM

    ILOM

    SSH 2.0 CLI

    LDAPMSFT Active DirectoryRADIUS

    root

    SSL SSL HTTPS

    SP ILOM

    Web SP

    IP

    Web ILOM CLI

    6 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM 2.0 Active Directory

    MIB SNMP

    SNMP IPMI SNMP IPMI IPMItool

    SP IPMI PET

    ECC SP

    Web CLI

    Web CLI

    BIOS SP IP SP

    SP IP IP

    1-2 ILOM ()

    1 ILOM 7

  • 8 Integrated Lights Out Manager 2.0 2007 10 A

  • 2

    ILOM

    CMM CMM ILOM

    ILOM ILOM SP CMM () IP

    10 ILOM 10 11 DHCP IP 13 IP 15 IP 15 ILOM 17 SP CMM 17

    18 IP SP 18 DHCP IP 20 IP SP 22 IP CMM

    23 IP 23 Web ILOM IP 25 CLI ILOM IP

    27

    9

  • ILOM ILOM 10 11 DHCP IP 13 IP 15 IP 15 ILOM 17 SP CMM 17

    2-1 ILOM

    2-1 ILOM

    DHCP IP

    DHCP IP

    DHCP SP CMM IP (CMM) ILOM

    CMM

    () CMM CMM NET MGT MGT ILOM (CMM) CMM

    10 Integrated Lights Out Manager 2.0 2007 10 A

  • DHCP IP DHCP SP CMM IP 12 DHCPDISCOVER 12 DHCP 12 SP MAC 13 DHCP IP

    SP IP DHCP IP SP CMM ILOM SP CMM

    11 DHCP IP 13 IP 18 IP SP

    ILOM () SP CMM IP ILOM (CLI) IP IP SP

    CMM ILOM IP CLI ( SSH ) ILOM

    Web IP IP SP CMM MGT LAN ILOM Web IP Web ILOM

    ILOM 3 4

    ILOM

    ILOM 15 ILOM

    SP

    SP 17 SP CMM 27

    () 17 SP CMM 27

    2-1 ILOM ()

    2 ILOM 11

  • DHCPDISCOVER SP CMM DHCPDISCOVER DHCP DHCP IP DHCPOFFER SP CMM

    DHCP IP DHCP SP MAC IP DHCP SP CMM MAC 12 SP MAC

    DHCP DHCP IP SP CMM DHCP DHCP (MAC) ILOM DHCP

    SP MAC DHCP IP SP SP CMM MAC

    2-2 MAC

    2-2 SP MAC

    ILOM

    SP

    SP

    SP MAC MAC

    CMM CMM CMM MAC CMM MAC

    12 Integrated Lights Out Manager 2.0 2007 10 A

  • DHCP IP DHCP IP SP 2-3 DHCP IP

    IP SP CMM IP 14 IP 14 15 IP

    2-3 DHCP IP

    DHCP

    ( ILOM DHCP )

    DHCP 1. [MAC address] MAC 2. [IP address] [MAC address] MAC

    IP 3. 2 IP Web ILOM DHCP ID, Date, Time, Description, IP Address, Host Name, MAC Address

    CMM CLI root ILOM show /SP/network

    show /CH/BLn/SP network

    0 CMMshow /CMM/network/CMM0 1 CMMshow /CMM/network/CMM1

    2 ILOM 13

  • IP IP SP CMM 2-4

    ILOM

    8N18 1 9600 (CTS/RTS) (XON/XOFF)

    CLI show CMM

    show

    CMMshow /CMM/serial/external show /SP/serial/external show /CH/BLn/SP/serial/external

    2-4 IP

    1 PC CMM SP CMM PC CMM CMM CMM ILOM SP IP

    2 14

    ILOM CLI IP

    3 ILOM CLI IP

    20 IP SP

    22 IP CMM

    14 Integrated Lights Out Manager 2.0 2007 10 A

  • IP ILOM Web CLI IP SP CMM IP CMM

    IP 23 IP

    IP ILOM IP SP SP CMM DHCP IP IP IP

    IP IP IP

    IP SP IP CMM IP ILOM Web ILOM CLI

    ILOM 3 ILOM

    IP

    ILOM ( 2-5 2-6) ILOM ILOM

    2-5 SP ILOM

    80 HTTP over TCP SP ILOM

    443 HTTPS over TCP SP ILOM

    5120 TCP SP ILOM CD

    5123 TCP SP ILOM

    5121 TCP SP ILOM

    7578 TCP SP ILOM

    2 ILOM 15

  • 22 SSH over TCP SSH Shell

    69 TFTP over UDP TFTP

    123 NTP over UDP NTP

    161 SNMP over UDP SNMP

    162 IPMI over UDP IPMI (PET) ()

    389 LDAP over UDP/TCP LDAP ()

    514 Syslog over UDP Syslog ()

    546 DHCP over UDP DHCP ()

    623 IPMI over UDP IPMI

    1812 RADIUS over UDP RADIUS

    2-6 CMM ILOM

    80 HTTP over TCP CMM ILOM ()

    443 HTTPS over TCP CMM ILOM ()

    8000 - 8009

    HTTP over TCP CMM ILOM (BL0-BL9)

    8400 - 8409

    HTTPS over TCP CMM ILOM (BL0-BL9)

    22 SSH over TCP SSH Shell

    69 TFTP over UDP TFTP

    123 NTP over UDP NTP

    161 SNMP over UDP SNMP

    389 LDAP over UDP/TCP

    LDAP ()

    514 Syslog over UDP Syslog ()

    546 DHCP over UDP DHCP ()

    1812 RADIUS over UDP RADIUS

    2-5 SP ILOM ()

    16 Integrated Lights Out Manager 2.0 2007 10 A

  • SP CMM IP SP CMM SP ILOM CMM ILOM ( DNSNISSMB) SP ( CMM) IP SP CMM [System Identification] SP ( CMM) ILOM SP CMM 27 Web

    SNMP ILOM

    ILOM ILOM 27

    2 ILOM 17

  • IP SP IP SP 18 DHCP IP 20 IP SP 22 IP CMM 27 Web 29 CLI

    DHCP IP DHCP IP

    1. DHCP (MAC) DHCP

    2. CMM (NET MGT) () (MGT) ()

    ILOM IP ILOM SP MAC ID DHCPDISCOVER ILOM IP [Network Settings] IP IP 23 IP

    3. DHCP IP DHCPOFFER DHCP IP

    18 Integrated Lights Out Manager 2.0 2007 10 A

  • 4. SP DHCP IP ILOM - CMM

    CMM ILOM root changeme Enter

    CMM cd /CMM/network/CMM0

    CMM IP show IP

    show /CH/BL0/SP/network

    CMM0 CMM0 CMMBL0 BL0 CMM 0 9CMM 0 1

    ILOM - SP

    ILOM root changeme Enter

    SP IP show /SP/network DHCP

    13 DHCP IP DHCP

    2 ILOM 19

  • IP SP IP SP

    1. SP CMM

    2. 8N18 1 9600 (CTS/RTS) (XON/XOFF)

    3. Enter SP ILOM [Login] Login:

    4. ILOM Enter

    ILOM ILOMroot/changeme 5 ILOM

    (->) CLI

    5. cd /SP/network

    20 Integrated Lights Out Manager 2.0 2007 10 A

  • 6. CLI IP

    () IP IP ILOM IP ILOM

    set pendingipaddress= SP IP

    set pendingipaddress=129.144.82.26 ILOM 129.144.82.26 SP IP

    set pendingipnetmask= SP

    set pendingipnetmask=255.255.255.0 ILOM 255.255.255.0 SP

    set pendingipgateway= SP

    set pendingipgateway=129.144.82.254 ILOM 129.144.82.254 SP

    setpendingipdiscovery= ILOM SP IP

    set pendingipdiscovery=static

    set commitpending=true (true)

    set pendingipaddress=129.144.82.26

    set pendingipnetmask=255.255.255.0

    set pendingipnetmask=129.144.82.254

    set commitpending=true

    2 ILOM 21

  • IP CMM IP CMM

    1. CMM CMM

    2. ILOM Enter

    ILOM ILOMroot/changeme 60 ILOM

    (->) CLI

    3. ILOM CLI CMM IP cd /CMM/network/CMM0

    CMM0 CMM0 CMM CMM CMM

    4. IP

    set pendingipaddress= CMM IP

    set pendingipaddress=129.144.82.26 ILOM 129.144.82.26 CMM IP

    set pendingipnetmask= CMM

    set pendingipnetmask=255.255.255.0 ILOM 255.255.255.0 CMM

    set pendingipgateway= CMM

    set pendingipgateway=129.144.82.254 ILOM 129.144.82.254 CMM

    22 Integrated Lights Out Manager 2.0 2007 10 A

  • SSH ILOM IP ILOM IP ILOM

    IP IP 23 Web ILOM IP 25 CLI ILOM IP

    Web ILOM IP ILOM Web IP SP CMM

    1. SP CMM IP Enter ILOM [Login]

    2. ILOM [Login]

    ILOM ILOMroot/changeme 5 ILOM

    ILOM

    set pendingipdiscovery= ILOM IP

    set pendingipdiscovery=static

    set commitpending=true (true)

    set pendingipaddress=129.144.82.26

    set pendingipnetmask=255.255.255.0

    set pendingipgateway=129.144.82.254

    set comitpending=true

    2 ILOM 23

  • 3. ILOM [Configuration] --> [Network] CMM [Network Settings]

    2-1 ILOM SP [Network Settings]

    2-2 ILOM CMM [Network Settings]

    4. SP IP

    a. [Use the Following IP Address]

    b. IP

    c. [Save] () IP IP ILOM IP ILOM

    24 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI ILOM IP ILOM CLI IP SP CMM

    1. SP CMM SSH

    CMM

    Shell (SSH)

    SP CMM Shell

    root SP CMM SSH SP

    ssh -l root

    changeme

    (->) CLI

    2. SP cd /SP/network

    cd /SP/network

    0 CMMcd /CMM/network/CMM0 1 CMMcd /CMM/network/CMM1

    3. show IP show /SP/network

    show /CH/BLn/SP network 0 CMMshow /CMM/network/CMM0 1 CMMshow /CMM/network/CMM1

    2 ILOM 25

  • 4. IP

    SSH ILOM IP ILOM IP ILOM

    set pendingipaddress= SP CMM IP

    set pendingipaddress=129.144.82.26 ILOM 129.144.82.26 SP IP

    set pendingipnetmask= SP CMM

    set pendingipnetmask=255.255.255.0 ILOM 255.255.255.0 SP ( CMM)

    set pendingipgateway= SP CMM

    set pendingipgateway=129.144.82.254 ILOM 129.144.82.254 SP ( CMM)

    setpendingipdiscovery= ILOM SP CMM IP

    set pendingipdiscovery=static

    set commitpending=true (true)

    set pendingipaddress=129.144.82.26

    set pendingipnetmask=255.255.255.0

    set pendingipnetmask=129.144.82.254

    set commitpending=true

    26 Integrated Lights Out Manager 2.0 2007 10 A

  • SP CMM ILOM SP CMM () ILOM ILOM

    27 Web 29 CLI

    17 SP CMM 17

    Web Web ILOM

    1. SP IP Enter ILOM [Login]

    2. ILOM [Login] ILOM

    2 ILOM 27

  • 3. [System Information] --> [Identification Information][Identification Information]

    2-3

    4. [SP Hostname] SP

    5. [SP System Identifier]

    6. [Save]

    28 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI CLI ILOM

    1. SP CMM SSH

    CMM

    Shell (SSH)

    SP CMM Shell

    root SP CMM SSH SP

    ssh -l root

    changeme

    (->) CLI

    2. SP -> set /SP hostname=-> set /SP system_identifier=

    2 ILOM 29

  • 30 Integrated Lights Out Manager 2.0 2007 10 A

  • 3

    ILOM

    ILOM (CLI) ILOM ILOM Web ILOM CLI

    32 CLI 32 CLI 34 CLI 36

    36 36 37 CLI ILOM 37 ILOM 37 ILOM

    /SP/ /CMM/

    31

  • CLI ILOM (CLI) Distributed Management Task Force Server Management Command-Line Protocol Specification 11.0a.8 (DMTF CLP)

    http://www.dmtf.org/standards/published_documents/DSP0214.pdf

    DMTF CLP

    DMTF CLP

    CLI ILOM CLI

    3-1 ILOM

    * /SP ILOM (SP)

    * /CMM /SP ILOM (CMM)

    * /SYS

    * /CH /SYS

    * /HOST SPARC

    32 Integrated Lights Out Manager 2.0 2007 10 A

  • /SP /SYS /SP /SYS

    3-1 ILOM CLI /SP

    5 ILOM

    3 ILOM 33

  • CLI ILOM CLI

    CLI ILOM CLI DMTF CLP

    CLI

    3-2 CLI

    cd

    create

    delete

    exit CLI

    help

    load

    reset

    set

    show

    start

    stop

    version

    34 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM CLI help examine

    3-3 CLI

    -default

    -destination

    -display -d

    -help -h

    -level -l

    -output -o ILOM -o table

    -script

    -source

    3 ILOM 35

  • 1. cd

    cd /SP/services/http

    2.

    set port=80

    set prop1=x

    set prop2=y

    =value

    set /SP/services/http port=80

    set /SP/services/http prop1=x prop2=y

    3-4

    > cd /SP/services/http

    > set port=80

    /SP/services/http

    80

    > cd /SP/services/http port=80 /SP/services/http 80

    36 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI ILOM ILOM 18 IP SP ILOM CLI ILOM

    ILOM 10 SSH Web Telnet ILOM

    ILOM Shell (SSH) ILOM CLI Shell

    UNIX SSH SSH root changeme

    SSH ILOM

    1. ILOM$ ssh root@ipaddress

    ipaddress SP IP

    2. Password: changeme

    ILOM ILOM root (changeme) root 63 CLI ILOM Root

    ILOM ILOM

    ILOM-> exit

    3 ILOM 37

  • 38 Integrated Lights Out Manager 2.0 2007 10 A

  • 4

    ILOM Web

    ILOM Web Web Web ILOM

    39 Web 40 41 Web 42 50 Web ILOM

    50 ILOM 53 SSL 54 55 ILOM

    Web ILOM Web ILOM Web ILOM CD-ROM ILOM 12 Web 5 ILOM

    39

  • Web MozillaFirefox Internet Explorer Web Web

    ILOM Web ILOM Web Web

    ILOM Web Solaris (9 10)

    Mozilla 1.4 1.7 Firefox 1.x

    Linux (Red HatSuSEUbuntu) Mozilla 1.x Firefox 1.x Opera 6.x

    Microsoft Windows (982000XPVista) Internet Explorer 5.56.x7.x Mozilla 1.x Firefox 1.x Opera 6.x

    Macintosh (OSX v10.1 ) Internet Explorer 5.2

    Mozilla 1.x Firefox 1.x Safari

    ILOM ILOM Java 1.5 (JRE 1.5) JRE JRE http://java.com 12

    40 Integrated Lights Out Manager 2.0 2007 10 A

  • Web ILOM Web

    4-1 ILOM Web

    Web

    (CMM) ILOM Web Web

    Web [About] [User] Web [Server] ILOM SP CMM [Refresh] [Refresh]

    [Log Out] Web

    Web Web [Refresh]

    4 ILOM Web 41

  • ILOM Web 42

    Web ILOM

    [System Information] ILOM [System Information] [System Information] [Versions] [Session Time-Out] [Components] [Identification Information]

    4-2 [System Information]

    42 Integrated Lights Out Manager 2.0 2007 10 A

  • [Versions] [Versions] ILOM 189 Web ILOM

    [Session Time-Out] [Session Time-Out] ILOM 54

    [Components] [Components] ILOM 103 Web

    [Identification Information] [Identification Information] SP 27 Web

    [System Monitoring] [System Monitoring] [System Information] [Sensor Readings] [Indicators] [Event Logs]

    4-3 [System Monitoring]

    4 ILOM Web 43

  • [Sensor Readings] [Sensor Readings] 112

    [Indicators] [Indicators] LED 116

    [Event Logs] [Event Logs] ID 118 ILOM

    [Configuration] [Configuration] [Configuration] [System Management Access] [Alert Management] [Network] [Serial Port] [Clock Settings] [Syslog] [SMTP Client] [SSH Server]

    4-4 [Configuration]

    44 Integrated Lights Out Manager 2.0 2007 10 A

  • [System Management Access] [System Management Access] [Web Server][SNMP] [SSL Certificate]

    [Web Server]

    [Web Server] Web HTTP Web HTTP 159 Web HTTP HTTPS Web

    [SNMP]

    [SNMP] SNMP 176 Web SNMP

    [SSL Certificate]

    [SSL Certificate] SSL SSL 53 SSL

    [SSH Server]

    [SSH Server] Shell (SSH) 153 Web SSH

    [Alert Management] [Alert Management] 134 ILOM Web

    [Network] [Network] ILOM 156 Web

    4 ILOM Web 45

  • [Serial Port] [Serial Port] 158 Web

    [Clock Settings] [Clock Settings] NTP 119 ILOM

    [Syslog] [Syslog] 129 Web IP

    [SMTP Client] [SMTP] SMTP 143 Web SMTP

    [User Management] [User Management] [User Management] [User Accounts] [Active Sessions] [LDAP] [RADIUS] [Active Directory]

    4-5 [User Management]

    46 Integrated Lights Out Manager 2.0 2007 10 A

  • [User Accounts] [User Accounts] ILOM 69 Web

    [Active Sessions] [Active Sessions] ILOM 76 Web

    [LDAP] [LDAP] LDAP ILOM 93 Web ILOM LDAP

    [RADIUS] [RADIUS] RADIUS ILOM 95 Web RADIUS

    [Active Directory] [Active Directory] Active Directory 78 Web Active Directory

    4 ILOM Web 47

  • [Remote Control] [Remote Control] [Remote Control] [Redirection] [Remote Power Control] [Mouse Mode Settings]

    4-6 [Remote Control]

    [Redirection] [Redirection] 199 Web ILOM

    [Remote Power Control] [Remote Power Control] 199 Web ILOM

    [Mouse Mode Settings] [Mouse Mode Settings] 199 Web ILOM

    48 Integrated Lights Out Manager 2.0 2007 10 A

  • [Maintenance] [Maintenance] [Maintenance] [Firmware Upgrade] [Reset SP]

    4-7 [Maintenance]

    [Firmware Upgrade] [Firmware Upgrade] ILOM Web ILOM

    [Reset SP] [Reset SP] (SP) 191 ILOM SP

    4 ILOM Web 49

  • Web ILOM Web SSL

    ILOM ILOM Web

    AC ILOM DHCP ILOM (DHCP) ILOM

    () Web

    ILOM IP IP 18 IP SP

    50 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM Web

    1. Web ILOM IP Web Web [Login]

    4-8 [Login]

    2.

    root changeme

    ID root ID changeme (CLI) Shell (SSH) Web

    4 ILOM Web 51

  • 3. [Log In]Web [Versions]

    4-9 [Versions]

    ILOM ILOM root (changeme) ILOM root 60 Web ILOM Root

    52 Integrated Lights Out Manager 2.0 2007 10 A

  • SSL ILOM HTTPS SSL

    SSL

    SSL

    1. ILOM

    2. [Configuration] --> [System Management Access] --> [SSL Certificate]

    [SSL Certificate Upload]

    4-10 [SSL Certificate Upload]

    3. SSL [Browse] SSL

    .pem

    4 ILOM Web 53

  • 4. [Upload] SSL

    [SSL Certificate Upload Status]

    5. [OK] ILOM Web SSL

    ILOM Web

    ILOM ILOM Web

    ILOM

    1. ILOM

    2. [System Information] --> [Session Time-Out][Session Time-Out]

    4-11 Web [Session Time-Out]

    3. [Session Time-Out] ILOM ILOM

    ILOM

    54 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM Web [Log Out]

    [Log Out] Web

    4 ILOM Web 55

  • 56 Integrated Lights Out Manager 2.0 2007 10 A

  • 5

    ILOM 10 ILOM ILOM Web (CLI)

    59 59 60 ILOM

    60 Web ILOM Root 63 CLI ILOM Root

    63 63 CLI 64 Web

    65 CLI 65 CLI 65 CLI 65 CLI 66 CLI 66 CLI 67 CLI 68 CLI 68 CLI

    57

  • 69 Web 69 Web 72 Web 75 Web 76 Web

    77 Active Directory 78 Web Active Directory 82 Web Active Directory 83 84 Active Directory

    87 91 LDAP 92 CLI ILOM LDAP 93 Web ILOM LDAP

    94 RADIUS 94 RADIUS 94 RADIUS 95 CLI RADIUS 95 Web RADIUS 96 RADIUS

    /SP/ /CMM/

    58 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM 10

    16

    ILOM ( Active DirectoryLDAP RADIUS) ILOM

    ILOM

    ILOM ILOM

    5 59

  • ILOM ILOM () root

    changeme

    (changeme) (root) ILOM ()

    SP CMM ILOM root changeme ILOM ILOM root (changeme) CMM ILOM root 60 Web ILOM Root

    Web ILOM Root root

    1. Web SP CMM IP ILOM Web [Login]

    2. ILOM [Login]

    a. (root) (changeme)

    b. [Log In]ILOM Web

    3. ILOM Web 4 SP

    4

    60 Integrated Lights Out Manager 2.0 2007 10 A

  • 4. ILOM Web [User Management] --> [User Accounts][User Account Settings]

    5-1 [User Account Settings]

    5. [User Account Settings] root [Edit]

    5 61

  • 6. [OK] [User Account Password]

    5-2 [User Account Password]

    7. [User Account Password]

    a. [Change]

    b. [New Password]

    c. [Confirm Password]

    d. [Save] root 7b 7c

    8. 2 7d

    62 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI ILOM Root ILOM root

    -> set /SP/users/root password=changeme

    -> set /SP/users/root password=changeme

    Changing password for user /SP/users/root...

    Enter new password again: ********

    New password was successfully set for user /SP/users/root

    ILOM

    CLI

    > set /SP/services/sso state=disabled|enabled

    5 63

  • Web

    1. ILOM Web [User Management] --> [User Accounts][User Account Settings]

    2. [Enable Single Sign On] 5-3

    5-3 [User Account Settings]

    64 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI ILOM (CLI)

    CLI

    > create /SP/users/username password=password role=administrator|operator

    -> create /SP/users/davemc

    Creating user...

    Enter new password: ********

    Enter new password again: ********

    Created /SP/users/davemc

    CLI

    > set /SP/users/username password=password role=administrator|operator

    CLI 1.

    > delete /SP/users/username

    -> delete /SP/users/davemc

    Are you sure you want to delete /SP/users/davemc (y/n)?

    2. y n

    5 65

  • CLI

    > show -display targets /SP/users

    -> show -display targets /SP/users

    /SP/users

    Targets:

    root

    davemc

    CLI

    > show /SP/users/username

    -> show /SP/users/davemc

    /SP/users/davemc

    Targets:

    Properties:

    role = Operator

    password = *****

    Commands:

    cd

    set

    show

    66 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI set

    > set [=value]

    user1

    > set /SP/users/user1 role=operator

    user1

    > set /SP/users/user1 password

    Changing password for user /SP/users/user1/password...

    Enter new password:********

    Enter new password again:********

    New password was successfully set for user /SP/users/user1

    5-1

    /SP/users/username role

    password

    administrator|operator

    operator

    5 67

  • CLI

    > show /SP/sessions

    -> show /SP/sessions

    /SP/sessions

    Targets:

    108

    Properties:

    Commands:

    cd

    show

    CLI

    > show /SP/sessions/108

    -> show /SP/sessions/108

    /SP/sessions/108

    Targets:

    Properties:

    username = root

    starttime = Tue Jun 5 10:04:05 2007

    type = shell

    Commands:

    cd

    show

    68 Integrated Lights Out Manager 2.0 2007 10 A

  • Web Web

    Web 1. ILOM Web

    (CLI) (IPMI) ILOM

    2. [User Management] --> [User Accounts][User Account Settings]

    3. [Users] [Add][Add User]

    5 69

  • 5-4 [Add User]

    4.

    a. [User Name]

    b. [Password] 8 16

    c. [Confirm Password]

    d. [Role] [Administrator] [Operator]

    70 Integrated Lights Out Manager 2.0 2007 10 A

  • 5-5 [Add User]

    e. [Save][User Account Settings] [User Account Settings]

    5 71

  • 5-6 [User Account Settings]

    Web ILOM

    (CLI) (IPMI) ILOM

    1. ILOM Web

    2. [User Management] --> [User Accounts][User Account Settings]

    72 Integrated Lights Out Manager 2.0 2007 10 A

  • 5-7 [User Account Settings]

    3. [Users]

    4. [Edit][Edit User]

    5 73

  • 5-8 [Edit User]

    5.

    a. [Change]

    b. [New Password] 8 16

    c. [Confirm New Password]

    6. [Role] [Administrator] [Operator]

    7. [Save] [Close] [User Account Settings]

    74 Integrated Lights Out Manager 2.0 2007 10 A

  • Web 1. ILOM Web

    2. [User Management] --> [User Accounts][User Account Settings]

    3.

    root

    5-9 [User Account Settings]

    4. [Users] [Delete]

    5 75

  • 5-10 [Delete User Configuration]

    5. [OK] [Cancel] [User Account Settings]

    Web 1. ILOM Web

    2. [User Management] --> [Active Sessions][Active Sessions] ILOM

    5-11 [Active Sessions]

    76 Integrated Lights Out Manager 2.0 2007 10 A

  • Active DirectoryILOM Active Directory Microsoft Windows Server 2003 Microsoft Windows 2000 Server

    Active Directory ()

    Active Directory (LAN)

    (DMZ)

    Active Directory

    Active Directory

    5 77

  • Active Directory Active Directory

    Web Active Directory1. ILOM Web

    2. [User Management] --> [Active Directory][Active Directory] Active Directory Active Directory 5-12

    5-12 Active Directory

    78 Integrated Lights Out Manager 2.0 2007 10 A

  • Active Directory 5-2 Active Directory

    5-2 Active Directory ()

    (Web) (CLI)

    State adminState Enabled Enabled | Disabled

    Role defaultRole None None | Administrator | Operator Active Directory

    IP Address ipaddress Active Directory IP

    Port port 0 (autoselect)

    autoselect SSL-LDAP

    TCP

    Timeout timeout 5 LDAP

    Strict Certificate Mode

    strictcertmode Enabled Enabled | Disabled

    Certificate File Status

    certfilestatus certificate present | not present; certificate.backup present | not present

    Web

    getcertfile ()

    TFTP Server CLI TFTP

    5 79

  • Active Directory Active Directory ( 5-13)

    MS Active Directory

    /

    Path and File Name

    CLI

    Restore Certificate

    CLI

    Remove Certificate

    CLI [Strict Certificate Mode]

    5-2 Active Directory () ()

    (Web) (CLI)

    80 Integrated Lights Out Manager 2.0 2007 10 A

  • 5-13 Active Directory

    Active Directory 5-3 5-4 [Admin Groups] [Operator Groups]

    5-5 5-13 [User Domains] 1 2 (dn)

    5-3 [Admin Groups]

    ID Name

    1 CN=SpSuperAdmin,OU=Groups,DC=davidc,DC=example,DC=sun,DC=com

    2

    5-4 [Operator Groups]

    ID Name

    1 CN=SpSuperOper,OU=Groups,DC=davidc,DC=example,DC=sun,DC=com

    2

    3

    4

    5

    5 81

  • 5-5

    5-5 [User Domains]

    Web Active Directory 1. ILOM Web

    2. [User Management] --> [Active Directory][Active Directory]

    3. [Active Directory] [Edit][Edit Active Directory Administrator Groups] [Edit Active Directory Operator Groups] [Edit Active Directory User Domains] [Name]

    5-14 Active Directory

    Name Domain

    1 @davidc.example.sun.com

    2 CN=,CN=Users,DC=davidc,DC=example,DC=sun,DC=com

    3

    4

    5

    82 Integrated Lights Out Manager 2.0 2007 10 A

  • 4. [Edit]

    5. [Save][Active Directory]

    6. [User Domains] [Name] LDAP

    domain = @davemc.example.sun.com

    domain = CN=,CN=Users,DC=davemc,DC=example,DC=sun,DC=com

    ILOM

    SP Active Directory LDAP Active Directory

    defaultRole Active Directory SP defaultRole administrator operator Active Directory

    5-1 Active Directory

    /home/dc150698> ssh -l davemc 10.x.xxx.xxxPassword:*******Sun(TM) Integrated Lights Out ManagerVersion 1.1Copyright 2005 Sun Microsystems, Inc. All rights reserved.->

    5-2 Active Directory

    /home/dc150698> ssh -l David A. Engineer 10.x.xxx.xxxPassword:*******Sun(TM) Integrated Lights Out ManagerVersion 1.1Copyright 2005 Sun Microsystems, Inc. All rights reserved.->

    5 83

  • Active Directory () SP Active Directory

    SP Active Directory SP

    Active Directory SSL LDAP

    CLI Active Directory CLI Active Directory

    CLI getcertfile getcertfile ()

    -> set getcertfile=tftp:////

    -> set getcertfile=remove|restore

    -> set getcertfile=remove

    84 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI strictcertmodestrictcertmode SSL strictcertmode SSL

    strictcertmode-> set strictcertmode=enabled

    CLI certfilestatuscertfilestatus strictcertmode strictcertmode

    -> show /SP/clients/activedirectory certfilestatus

    -> show /SP/clients/activedirectory certfilestatus

    Properties:

    certfilestatus = certificate not present;certificate.backup not present;

    5 85

  • Web Active Directory Web Active Directory

    5-15 Active Directory

    5-15 Active Directory

    Web 1. ILOM Web

    2. [User Management] --> [Active Directory][Active Directory] 5-15

    3. [TFTP Server] [Path and File Name] 5-15 1a 1b

    4. [Save] 5-15 2

    [Restore Certificate] [Remove Certificate]

    1b2

    3

    4

    1a

    86 Integrated Lights Out Manager 2.0 2007 10 A

  • Web 1. ILOM Web

    2. [User Management] --> [Active Directory][Active Directory] 5-15 3

    3.

    Web 1. ILOM Web

    2. [User Management] --> [Active Directory][Active Directory] 5-15 4

    3. [Enable] [Strict Certificate Mode]

    ILOM (LDAP) ( OpenLDAP )LDAP LDAP http://www.openldap.org/

    LDAPLDAP -LDAP LDAP

    LDAP

    5 87

    http://www.openldap.org/

  • LDAP LDAP LDAP LDAP ( LDAP ) LDAP LDAP

    LDAP LDAP LDAP (dn) LDAP

    LDAP

    LDAP LDAP LDAP LDAP TCP/IP 389

    LDAP LDAP LDAP LDAP

    88 Integrated Lights Out Manager 2.0 2007 10 A

  • LDAP LDAP 5-16

    5-16 LDAP

    (dn) DN

    jsmith DN

    dn: uid=jsmith, ou=people, dc=sun.com

    uid IDou dc DN

    5 89

  • 5-17 LDAP

    LDAP LDAP LDAP LDAP ILOM CLI Web ILOM

    LDAP LDAP IP

    LDAP Linux Solaris

    90 Integrated Lights Out Manager 2.0 2007 10 A

  • LDAP 1. ILOM GNU (

    MD5 )

    userPassword: {CRYPT}ajCa2He4PJhNo

    userPassword: {CRYPT}$1$pzKng1$du1Bf0NWBjh9t3FbUgf46.

    ILOM LDAP

    2. posixAccount shadowAccount (RFC 2307)

    3. LDAP ILOM LDAP LDAP ILOM LDAP

    5-6 LDAP

    uid ILOM

    uidNumber

    gidNumber

    userPassword

    homeDirectory (ILOM )

    loginShell (ILOM )

    5 91

  • CLI ILOM LDAP 1.

    > set /SP/clients/ldap binddn="cn=proxyuser, ou=people, ou=sales, dc=sun, dc=com" bindpw=password

    2. LDAP IP > set /SP/clients/ldap ipaddress=ldapipaddress

    3. LDAP 389

    > set /SP/clients/ldap port=ldapport

    4. LDAP > set /SP/clients/ldap searchbase="ou=people, ou=sales, dc=sun, dc=com"

    LDAP

    5. LDAP > set /SP/clients/ldap state=enabled

    6. LDAP LDAP ILOM

    ILOM LDAP LDAP ILOM

    92 Integrated Lights Out Manager 2.0 2007 10 A

  • Web ILOM LDAP 1. ILOM Web

    2. [User Management] --> [LDAP][LDAP Settings]

    5-18 [LDAP Settings]

    3. State [Enabled] LDAP Role LDAP [Operator]

    [Administrator] IP Address LDAP IP Port LDAP Searchbase LDAP Bind DN LDAP (DN)ILOM

    LDAP Bind Password

    4. [Save]

    5. LDAP LDAP ILOM

    ILOM LDAP LDAP ILOM

    5 93

  • RADIUS ILOM (RADIUS)RADIUS RADIUS RADIUS RADIUS

    RADIUS RADIUS RADIUS RADIUS RADIUS

    RADIUS () ILOM RADIUS

    ILOM RADIUS ILOM RADIUS

    RADIUS 5-7 Web CLI RADIUS

    5-7 RADIUS Web CLI

    Web CLI

    State state enabled|disabled RADIUS

    Role defaultroleadministrator|operator

    RADIUS

    IP Address ipaddress ipaddress RADIUS IP

    Port port portnum RADIUS 1812

    Shared Secret secret text RADIUS

    94 Integrated Lights Out Manager 2.0 2007 10 A

  • RADIUS 10 ILOM RADIUS ILOM RADIUS

    57 RADIUS

    CLI RADIUS1. ILOM CLI

    2. /SP/clients/radius 96 RADIUS

    3. 5-7

    Web RADIUS1. ILOM Web

    2. [User Management] --> [RADIUS][RADIUS Settings]

    5-19 [RADIUS Settings]

    3. 5-7

    4. [Save]

    5 95

  • RADIUS RADIUS

    show /SP/clients/radius

    RADIUS

    show /SP/clients/radius

    defaultrole RADIUS

    ipaddress RADIUS IP

    port RADIUS 1812

    secret RADIUS

    state RADIUS

    96 Integrated Lights Out Manager 2.0 2007 10 A

  • set /SP/clients/radius

    RADIUS

    set /SP/clients/radius [defaultrole=[Administrator|Operator] ipaddress=radiusserverIP port=port# secret=radiussecret state=[enabled|disabled]]

    -> show /SP/clients/radius

    /SP/clients/radius Targets:

    Properties: defaultrole = Operator ipaddress = 129.144.36.142 port = 1812 secret = (none) state = enabled

    Commands: cd set show

    ->

    5 97

  • defaultrole RADIUS ()

    ipaddress RADIUS IP port RADIUS 1812 secret RADIUS state RADIUS

    show /SP/clients

    LDAPNTPRADIUS SYSLOG

    show /SP/clients

    -> set /SP/clients/radius state=enabled ipaddress=10.8.145.77 Set 'state' to 'enabled'Set 'ipaddress' to '10.8.145.77

    98 Integrated Lights Out Manager 2.0 2007 10 A

  • ntp syslog RADIUS LDAP

    -> show /SP/clients

    /SP/clients Targets:

    ldapntpradiussyslog

    Properties:

    Commands: cd show

    5 99

  • 100 Integrated Lights Out Manager 2.0 2007 10 A

  • 6

    ILOM ILOM

    102 102 CLI 103 Web

    104 105 CLI 105 CLI 106 CLI 106 Web 107 Web

    107 107 CLI 107 Web

    108 108 CLI 109 Web

    /SP/ /CMM/

    101

  • CLI 1. ILOM CLI

    2. -> show component_name type

    -> show /SYS/MB type Properties:

    type = Motherboard Commands: show

    fru_part_number fru_manufacturer fru_serial_number

    fru_name fru_description fru_version

    chassis_serial_number chassis_part_number product_name

    product_serial_number product_part_number customer_frudata

    102 Integrated Lights Out Manager 2.0 2007 10 A

  • Web 1. ILOM Web

    2. [System Information] --> [Components][Component Management]

    6-1 [Component Management]

    6 103

  • 3. [Component Management Status]

    6-2 [Component Information]

    / 104 / 107 121

    ILOM CLI Web

    104 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI 1. ILOM CLI

    2. ILOM > set prepare_to_remove_action=true

    -> set /CH/RFM0 prepare_to_remove_action=true

    Set prepare_to_remove_action to true

    CLI

    1. ILOM CLI

    2. ILOM > show prepare_to_remove_status

    -> show /CH/RFM0 prepare_to_remove_status

    Properties:

    prepare_to_remove_status = Ready|NotReady

    Commands:

    cd

    set

    show

    start

    stop

    Ready|NotReady

    6 105

  • CLI

    1. ILOM CLI

    2. ILOM > set return_to_service_action=true

    -> set /CH/RFM0 return_to_service_action=true

    Set return_to_service_action to true

    Web 1. ILOM Web

    2. [System Information] --> [Components][Component Management]

    6-3 [Component Management]

    3.

    4. [Actions] [Prepare to Remove]

    106 Integrated Lights Out Manager 2.0 2007 10 A

  • Web 1. ILOM Web

    2. [System Information] --> [Components][Component Management]

    3.

    4. [Action] [Return to Service]

    CLI 1. ILOM CLI

    2. ILOM -> set /SYS/MB/CMP0/P0/C0 component_state=enabled | disabled

    Web 1. ILOM Web

    2. [System Information] --> [Components][Component Management]

    3.

    4. [Actions] [Enable] [Disable]

    6 107

  • ILOM CLI Web

    CLI 1. ILOM CLI

    2. ILOM > show /CMM/policy

    -> show /CMM/policy

    /CMM/policy

    Targets:

    Properties:

    Policy1Name = enabled

    Policy2Name = enabled

    Policy2Name = enabled

    Commands:

    cd

    set

    show

    3. ILOM > set /CMM/policy

    -> set /CMM/Policy1Name=enabled

    /CMM/Policy1Name=enabled

    108 Integrated Lights Out Manager 2.0 2007 10 A

  • Web

    1. ILOM Web

    2. [Configuration] --> [Policy][Policy Configuration]

    3.

    4. [Action] [Enable] [Disable]

    6-4 [Policy Configuration]

    6 109

  • 110 Integrated Lights Out Manager 2.0 2007 10 A

  • 7

    ILOM ILOM ILOM Web (CLI) ILOM

    112 112 116 118 ILOM 119 ILOM 120 121

    123 ILOM 123 Web 124 Web 125 Web ILOM 126 CLI ILOM 120 CLI 128 Web 129 Web IP 130 CLI IP

    131 131 132

    134 ILOM Web 135 135 Web 136 Web 136 Web

    137 ILOM CLI 137 CLI 140 CLI 141 CLI

    142 SMTP 143 Web SMTP 143 CLI SMTP

    111

  • ILOM ILOM

    112 116 ILOM

    118 ILOM Sun

    Fire X4100 X4200 121

    IPMI PET SNMP 131

    ILOM

    ILOM ILOM ILOM

    112 Integrated Lights Out Manager 2.0 2007 10 A

  • Web ILOM Web [System Monitoring] --> [Sensor Readings] FRU ()

    7-1 ILOM Web [Sensor Readings]

    [Sensor Readings] /SYS/T_AMB

    7 113

  • 7-2 /SYS/T_AMB [Sensor Properties]

    ILOM Web 123 Web

    CLI ILOM CLI FRU /SYS /CH

    ILOM CLI cd show

    cd /SYS/T_AMB

    show

    114 Integrated Lights Out Manager 2.0 2007 10 A

  • Type = Sensor Class = Threshold Sensor Value = 32.000 degree C Upper = non-recov_threshold = 80.00 degree C Upper critical_threshold = 75.00 degree C Upper noncritical_threshold = 70.00 degree C Lower non_recov_threshold = 0.00 degree C Lower critical_threshold = 0.00 degree C Lower noncritical_threshold = 0.00 degree C

    ILOM CLI cd show 0

    cd /SYS/HDD0_PRSNT

    show

    Type = Entity Presence Class = Discrete Indicator Value = Present

    7 115

  • LED ILOM ILOM LED (FRU) FRU

    ILOM Web ILOM CLI

    ILOM

    ILOM ILOM LED

    ILOM Web CLI 117 Web 117 CLI

    LED LED (FRU)

    116 Integrated Lights Out Manager 2.0 2007 10 A

  • Web ILOM Web [Indicators] [Actions]

    7-3 ILOM Web [Indicators]

    ILOM Web 124 Web

    CLI ILOM CLI /SYS /CH cd show set set cd show

    cd /SYS/ cd /CH/show

    Targets:

    Properties:

    Type = indicator

    Value = Off

    Commands:

    cd

    set

    show

    7 117

  • set Commands

    set value=

    ILOM ILOM ILOM IPMI ILOM ILOM

    ILOM Web CLI ILOM ILOM 125 Web ILOM 126 CLI ILOM

    7-4 ILOM Web ILOM

    118 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM ILOM UTC/GMT ILOM

    ILOM UTC/GMT ILOM NTP IP ILOM ILOM

    Web ILOM Web [Configuration] --> [Clock Settings] ILOM

    7-5 [Clock Settings]

    ILOM Web 128 Web

    7 119

  • CLI show ILOM CLI ILOM

    show /sp/clock

    set CLI ILOM set target

    ILOM CLI NTP IP ILOM NTP IP NTP NTP IP

    set /SP/clients/ntp/server/1 address=

    set /SP/clock/usentpserver=enabled

    ILOM CLI ILOM

    ILOM SP ILOM

    ILOM ILOM ILOM IP 129 Web IP 130 CLI IP

    120 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM

    LED ILOM ILOM

    ILOM Web ILOM CLI 121 Web 123 CLI

    ILOM Sun Fire X4100 X4200

    Web ILOM Web [Fault Management]

    7-6 [Fault Management]

    [Fault Management] IDFRU ID ID 0(CH/PS3/EXTERNAL/AC_INPUT)

    7 121

  • 7-7 [Fault Properties]

    ILOM Web [Component Management]

    7-8 [Component Management]

    [Component Management] 10 ILOM

    122 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI ILOM CLI show

    show /SP/faultmgmt

    show /CH/faultmgmt

    ILOM

    ILOM ILOM 123 Web 124 Web 125 Web ILOM 126 CLI ILOM 128 Web 129 Web IP 130 CLI IP

    Web ILOM Web

    1. Web SP CMM IP ILOM Web [Login]

    2. ILOM [Login] [OK]ILOM Web

    3. Web [System Monitoring] --> [Indicators][Indicators]

    7 123

  • 4. [Indicators]

    a.

    b. [Actions] [Turn LED Off] [Set LED to Fast Blink]

    c. [OK]

    Web ILOM Web

    1. Web SP CMM IP ILOM Web [Login]

    2. ILOM [Login] [OK]ILOM Web

    3. Web [System Monitoring] --> [Sensors Readings][Sensor Readings]

    4. [Sensor Readings]

    a.

    b.

    124 Integrated Lights Out Manager 2.0 2007 10 A

  • Web ILOM ILOM Web ILOM

    1. Web SP CMM IP ILOM Web [Login]

    2. ILOM [Login] [OK]ILOM Web

    3. Web [System Monitoring] --> [Event Logs][Event Log]

    4. [Event Log]

    Web

    [Clear Event Log] [OK]

    ILOM IPMI ILOM IPMI ILOM IPMI

    Event ID 1

    Class/Type Audit/ Log /

    IPMI/Log IPMI SEL Chassis/State Chassis/Action // FRU

    FMA/Fault (FMA) FMA

    FMA/Repair FMA

    Severity CriticalMajor Minor

    Date/Time (NTP) ILOM ILOM (UTC)

    Description

    7 125

  • CLI ILOM ILOM CLI

    1. SP CMM SSH

    CMM

    Shell (SSH)

    SP CMM Shell

    root SP CMM

    SSH SP ssh -l root Password: changeme

    (->)

    2. SPcd /SP/logs/event SPcd /CH/BLn/SP/logs/event CMMcd /CMM/logs/event

    3. show list

    126 Integrated Lights Out Manager 2.0 2007 10 A

  • 4. q

    .

    () q

    a. set clear=true

    b. y

    n

    ILOM IPMI ILOM IPMI ILOM IPMI

    Event ID 1

    Class/Type Audit/ Log /

    IPMI/Log IPMI SEL Chassis/State Chassis/Action // FRU

    FMA/Fault (FMA) FMA

    FMA/Repair FMA

    Severity CriticalMajor Minor

    Date/Time (NTP) ILOM ILOM (UTC)

    Description

    7 127

  • Web NTP IP

    1. Web SP CMM IP ILOM Web [Login]

    2. ILOM [Login] [OK]ILOM Web

    3. Web [Configuration] --> [Clock Settings][Clock Settings]

    4. [Clock Settings]

    SP

    a. [date] mm/dd/yy

    b. [time] NTP IP

    a. [Synchronize Time Using NTP] [Enabled]

    b. [Server 1] NTP IP

    c. () [Server 2] NTP IP

    5. [Save]

    128 Integrated Lights Out Manager 2.0 2007 10 A

  • Web IP Web ILOM IP

    1. Web SP CMM IP ILOM Web [Login]

    2. ILOM [Login] [OK]ILOM Web

    3. ILOM Web [Configuration] --> [Syslog][Syslog]

    7-9 [Syslog]

    4. [IP Address 1] [IP Address 2] IP

    5. [Save]

    7 129

  • CLI IP CLI IP

    1. SP CMM SSH

    CMM

    Shell (SSH)

    SP CMM Shell

    root SP CMM

    SSH SP ssh -l root Password: changeme

    (->)

    2. SPcd /SP/clients/syslog SPcd /CH/BLn/SP/clients/syslog CMMcd /CMM/clients/syslog

    3. show SP /SP/clients/syslog

    Targets:

    Properties:

    destination_ip1 = 0.0.0.0

    destination_ip2 = 0.0.0.0

    Commands:

    cd

    set

    show

    130 Integrated Lights Out Manager 2.0 2007 10 A

  • 4. set IP 1 ( IP2) IP IP IP 11.222.33.4set destination_ip1=111.222.33.4

    5. Enter IP IP 111.222.33.4

    Set destination_ip1 to 111.222.33.4

    ILOM ILOM

    ILOM LocalTime=GMT ( UTC) LocalTime ILOM UTC ILOM 119 ILOM

    ILOM Web CLI ILOM 15 ILOM

    ILOM IPMI PET SNMP

    (CMM) SNMP IPMI PET

    ( 132 )

    7 131

  • ILOM Alert Type Alert Level Alert Destination SNMP Version ( SNMP ) SNMP Community Name User Name ( SNMP )

    ( 7-1)

    7-1

    Alert Type ILOM

    IPMI PET Alerts IPMI (PET) (CMM) ILOM IPMI PET IP IPMI PET IPMI PET

    SNMP Trap AlertsILOM IP SNMP SNMP SNMP

    Email Notification AlertsILOM ILOM ILOM SMTP 143 Web SMTP

    Alert Destination

    IPMI PET SNMP IP

    ILOM

    132 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM 134 ILOM Web 137 ILOM CLI 142 SMTP

    Alert Level ILOM

    ILOM Minor Minor

    Major

    Critical

    Down DisabledILOM Disabled ILOM IPMI ILOM SNMP SNMP ( SNMP )minormajorcritical down SNMP

    SNMP Version SNMP SNMP 12c 3 SNMP

    SNMP Community Name

    User Name

    SNMP SNMP SNMPv3 SNMP v1 v2c SNMP SNMP v.3 SNMP SNMP v.3 ILOM SNMP SNMP SNMP ILOM SNMP 10

    SMTP

    SMTP State

    SMTP Server IP SMTP IP

    SMTP Port SMTP

    7-1 ()

    7 133

  • ILOM Web ILOM [Alert Settings] Web 15 [Actions]

    [Alert Settings] [Send Test Alert]

    7-10 [Alert Settings]

    ILOM Web

    135 135 Web 136 Web 136 Web

    134 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM

    ILOM

    SNMP v.3 SNMP ILOM SNMP SNMP ILOM SNMP SNMP SNMP ILOM SNMP 10

    ILOM ILOM

    Web ILOM

    1. Web SP CMM IP ILOM Web [Login]

    2. ILOM [Login] [OK]ILOM Web

    3. Web [Configuration] --> [Alert Management]

    CMM Web SP CMM SP SP () [Configuration] --> [Alert Management]

    [Alert Settings]

    4. [Alert Settings]

    a.

    b. [Actions] [Edit]

    c. [Properties] SNMP

    132

    d. [Save] [Properties]

    7 135

  • Web ILOM

    1. Web SP CMM IP ILOM Web [Login]

    2. ILOM [Login] [OK]ILOM Web

    3. Web [Configuration] --> [Alert Management]

    CMM Web SP CMM SP SP () [Configuration] --> [Alert Management]

    [Alert Settings]

    4. [Alert Settings] [Actions] [Edit]

    5. [Properties] [Alert Levels] [Disabled]

    Web ILOM ILOM

    1. Web SP CMM IP ILOM Web [Login]

    2. ILOM [Login] [OK]ILOM Web

    3. Web [Configuration] --> [Alert Management]

    CMM Web SP CMM SP SP () [Configuration] --> [Alert Management]

    [Alert Settings]

    4. [Alert Settings] [Send Test Alert] ILOM [Alert Settings]

    136 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM CLI ILOM (CLI) ILOM 15 ILOM

    ILOM CLI

    ILOM CLI 137 CLI 139 140 CLI 141 CLI 141 CLI

    CLI 7-2 ILOM CLI CLI

    7 137

  • 7-2 CLI

    CLI

    show show

    show /SP/alertmgmt/rules/1

    /SP/alertmgmt/rules/1 Properties:

    community_or_username = public destination = 129.148.185.52

    level = minor

    snmp_version = 1

    type = snmptrap

    Commands:

    cd set

    show

    show /SP/alertmgmt/rules/1 type

    Properties: type = snmptrap

    Commands:

    set

    show

    /SP/alertmgmt/rules show 1//SP/alertmgmt/rules/1Targets:Properties:

    community_or_username = public destination = 129.148.185.52 level = minor snmp_version = 1 type = snmptrapCommands:

    cd set show

    138 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM

    ILOM

    SNMP v.3 SNMP ILOM SNMP SNMP ILOM SNMP SNMP SNMP ILOM SNMP 10

    ILOM ILOM

    cd cd SP cd /SP/alertmgmt

    set set

    set /SP/alertmgmt/rules/1 type=ipmipet

    ( /SP/alertmgmt)set rules/1 type=ipmipet

    ( /SP/alertmgmt/rules/1)set type=ipmipet

    7-2 CLI ()

    CLI

    7 139

  • CLI 1. SP CMM SSH

    CMM

    Shell (SSH)

    SP CMM Shell

    root SP CMM

    SSH SP ssh -l root

    Password: changeme

    (->)

    2. cd /SP/alertmgmt

    cd /SP/alertmgmt

    CMMcd /CMM/alertmgmt

    3. show

    show /SP/alertmgmt/rules/1

    show /CH/BLn/SP/alertmgmt/rules/1

    CMMshow /CMM/alertmgmt/CMM/rules/1

    4. set IPMI PET 1

    set type=ipmipet

    SNMP SNMP

    132 7-1

    140 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI ILOM CLI

    1. SP CMM SSH

    CMM

    Shell (SSH)

    SP CMM Shell

    root SP CMM

    SSH SP ssh -l root

    Password: changeme

    (->)

    2. cd

    SPcd /SP/alertngnt/rules/n SPcd /CH/BLn/SP/alertmgmt/rules/n CMMcd /CMM/alertmgmt/CMM/rules/n

    3. set level=disable

    CLI ILOM ILOM

    1. SP CMM SSH

    CMM

    Shell (SSH)

    7 141

  • SP CMM Shell

    root SP CMM

    SSH SP ssh -l root

    Password: changeme

    (->)

    2. cd

    SPcd /SP/alertmgmt/rules SPcd /CH/BLn/SP/alertmgmt/rules CMMcd /CMM/alertmgmt/CMM/rules

    n 1 15

    3. set testalert=true

    SMTP ILOM SMTP ILOM SMTP SMTP IP

    ILOM SMTP

    143 Web SMTP 143 CLI SMTP

    ILOM SMTP SMTP IP

    142 Integrated Lights Out Manager 2.0 2007 10 A

  • Web SMTP Web ILOM SMTP

    1. Web SP CMM IP ILOM Web [Login]

    2. ILOM [Login] [OK]ILOM Web

    3. Web [Configuration] --> [SMTP Client]

    4. [SMTP Client]

    5. [Save] SMTP

    CLI SMTP CLI ILOM SMTP

    1. SP CMM SSH

    CMM

    Shell (SSH)

    SP CMM Shell

    root SP CMM

    SSH SP ssh -l root

    Password: changeme

    (->)

    SMTP

    SMTP State

    SMTP Server IP SMTP IP

    SMTP Port SMTP

    7 143

  • 2. cd clients/smtp

    SPcd /SP/clients/smtp SPcd /CH/BLn/SP/clients/smtp CMMcd /CMM/clients/smtp

    3. show smtp SP smtp show

    /SP/clients/smtp

    Targets

    Properties

    address = 0. 0. 0. 0

    port = 25

    state = enabled

    Commands:

    cd

    set

    show

    4. set SMTP IP

    set address=222.333.44.5

    5. Return set address=222.333.44.5

    Set address=222.333.44.5

    144 Integrated Lights Out Manager 2.0 2007 10 A

  • 8

    ILOM ILOM Web

    146 CLI ILOM 146 CLI 146 CLI 148 CLI 149 CLI 150 CLI HTTP HTTPS Web

    151 Shell 151 CLI 152 CLI 153 CLI SSH 153 Web SSH 154 CLI 155 Web 155 CLI SSH 155 Web SSH

    156 Web ILOM 156 Web 156 Web 158 Web 159 Web 159 Web HTTP HTTPS Web

    /SP/ /CMM/

    145

  • CLI ILOM ILOM (CLI) ILOM

    ILOM (pendingipaddress pendingipgateway) commitpending true

    ILOM IP ILOM IP DHCP ILOM IP ILOM

    CLI 1. ILOM CLI

    2. > show /SP/network

    CLI set

    1. ILOM CLI

    2. > set /SP/network

    146 Integrated Lights Out Manager 2.0 2007 10 A

  • ILOM

    ILOM IP

    -> set /SP/network pendingipaddress=nnn.nn.nn.nn commitpending=true

    ILOM IP

    DHCP

    -> set /SP/network pendingipdiscovery=static pendingipaddress=nnn.nn.nn.nn pendingipgateway=nnn.nn.nn.nn pendingipnetmask=nnn.nn.nn.nn commitpending=true

    commitpending true

    ILOM Web (CLI)

    ILOM ILOM ILOM ( 0COM1 /dev/ttyS0)

    8-1 ILOM

    /SP/network ipaddress

    ipdiscovery

    ipgateway

    ipnetmask

    macaddress ILOM MAC

    commitpending

    pendingipaddress

    pendingipdiscovery

    pendingipgateway

    pendingipnetmask

    true|()

    dhcp|static

    ()

    none

    dhcp

    none

    255.255.255.255

    8 ILOM 147

  • ILOM (9600 8N1 [8 1 ] )

    ILOM RJ-45 ILOM

    CLI 1. ILOM CLI

    2.

    -> show /SP/serial/external

    -> show /SP/serial/host

    148 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI set ILIM commitpending true

    1. ILOM CLI

    2.

    -> set target [propertyname=value]

    ILOM

    () 9600 57600

    -> set /SP/serial/host pendingspeed=57600 commitpending=true

    0COM1 /dev/ttys0 ILOM

    8-2 ILOM

    /SP/serial/external commitpending

    flowcontrol

    pendingspeed

    speed

    true|()

    none

    9600

    ()

    none

    9600

    9600

    /SP/serial/host commitpending

    pendingspeed

    speed

    true|()

    9600

    ()

    ()

    9600

    8 ILOM 149

  • CLI HTTP HTTPS Web ILOM HTTP HTTPS ILOM HTTP HTTPSILOM HTTP HTTPS

    1. ILOM CLI

    2. set /SP/services/http

    /SP/services/http /SP/services/https

    8-3 HTTP HTTPS

    8-4 HTTPHTTPS

    8-3 HTTP HTTPS

    /SP/services/http secureredirect enabled|disabled

    enabled

    servicestate enabled|disabled

    disabled

    port 80

    /SP/services/https servicestate enabled|disabled

    enabled

    port 443

    8-4 HTTPHTTPS

    HTTP /SP/services/http secureredirect disabled

    /SP/services/http servicestate enabled

    /SP/services/https servicestate disabled

    HTTP HTTPS /SP/services/http secureredirect disabled

    /SP/services/http servicestate enabled

    /SP/services/https servicestate enabled

    HTTPS /SP/services/http secureredirect disabled

    150 Integrated Lights Out Manager 2.0 2007 10 A

  • Shell Shell (SSH) ILOM (CLI) SSH ILOM ILOM RSA DSA

    CLI SSH SP

    ssh -l username

    Password: ********

    (->) CLI

    /SP/services/http servicestate disabled

    /SP/services/https servicestate enabled

    HTTP HTTPS

    /SP/services/http secureredirect enabled

    /SP/services/http servicestate disabled

    /SP/services/https servicestate enabled

    8-4 HTTPHTTPS ()

    8 ILOM 151

  • CLI

    /SP/services/ssh/keys/rsa|dsa

    RSA

    -> show /SP/services/ssh/keys/rsa

    /SP/services/ssh/keys/rsa

    Targets:

    Properties:

    fingerprint = ca:c0:05:ff:b7:75:15:a0:30:df:1b:a1:76:bd:fe:e5

    length = 1024

    publickey = AAAAB3NzaC1yc2EAAAABIwAAAIEAthvlqgXbPIxN4OEvkukKupdFPr8GDaOsKGg7BESVlnny4nX8yd8JC/hrw3qDHmXIZ8JAFwoLQgjtZCbEsgpn9nNIMb6nSfu6Y1tpTtUZXSGFBZ48ROmU0SqqfR3i3bgDUR0siphlpgV6Yu0Zd1h3549wQ+RWk3vxqHQiFfzhv9c=

    Commands:

    cd

    show

    DSA

    -> show /SP/services/ssh/keys/dsa

    /SP/services/ssh/keys/dsa

    Targets:

    Properties:

    fingerprint = 6a:90:c7:37:89:e6:73:23:45:ff:d6:8e:e7:57:2a:60

    152 Integrated Lights Out Manager 2.0 2007 10 A

  • length = 1024

    publickey = AAAAB3NzaC1kc3MAAACBAInrYecNH86imBbUqE+3FoUfm/fei2ZZtQzqrMx5zBm1bHFIaFdRQKeoQ7gqjc9jQbO7ajLxwk2vZzkg3ntnmqHz/hwHvdho2KaolBtAFGcVfLIdzGVxi4I3phVb6anmTlbqI2AILAa7JvQ8dEGbyATYR9A/pf5VTac/TQ70O/J9AAAAFQCIUavkex7wtEhC0CH3s25ON0I3CwAAAIBNfHUop6ZN7i46ZuQOKhD7MkjQgdHy+8MTBkupVfXqfRE9Zw9yrBZCNsoD8XEeIeyP+puO5k5dJvkzqSqrTVoAXyYhqewyZMFE7stutugw/XEmyjq+XqBWaiOAQskdiMVnHa3MSg8PKJyWP8eIMxD3rIu7PTzkV632uBxzwSwfAQAAAIAtA8/3odDJUprnxLgHTowc8ksGBj/wJDgPfpGGJHBKB1FDBMhSsRbwh6Z+s/gAf1f+S67HJBTUPsVSMz+czmamc1oZeOazT4+zeNG6uCl/u/5/JmJSdkguc1FcoxtBFqfO/fKjyR0ecWaU7L4kjvWoSsydHJ0pMHasEecEBErDlg==

    Commands:

    cd

    show

    CLI SSH SSH

    -> set /SP/services/ssh state=enabled | disabled

    Web SSH1. ILOM

    2. [Configuration] --> [System Management Access] --> [SSH Server]

    3. [SSH Server] [Enabled] [Disabled]

    8 ILOM 153

  • 8-1 [SSH Server Settings]

    CLI 1.

    -> set /SP/services/ssh generate_new_key_type=dsa | rsa

    2. true

    -> set /SP/services/ssh generate_new_key_action=true

    154 Integrated Lights Out Manager 2.0 2007 10 A

  • Web 1. ILOM

    2. [Configuration] --> [System Management Access] --> [SSH Server]

    3. [Generate RSA Key] RSA [Generate DSA Key] DSA [OK] [Cancel]

    8-2

    CLI SSH SSH

    SSH

    SSH

    -> set /SP/services/ssh restart_sshd_action=true

    Web SSH SSH

    SSH

    1. ILOM

    2. [Configuration] --> [System Management Access] --> [SSH Server]

    3. [SSH Server] [Restart SSH Server]

    8 ILOM 155

  • Web ILOM ILOM Web ILOM

    ILOM (DHCP) IP

    Web 1. ILOM ILOM Web

    2. [Configuration] --> [Network] [Network Settings] MAC

    DHCP IP

    Web 1. ILOM ILOM Web

    2. [Configuration] --> [Network][Network Settings]

    156 Integrated Lights Out Manager 2.0 2007 10 A

  • 8-3 [Network Settings]

    3. [Network Settings] 8-5

    8-5 [Network Settings]

    MAC Address ILOM (MAC) MAC CMM BIOS [Setup] ILOM MAC

    Obtain an IP Address Automatically (use DHCP)

    DHCP IP

    IP Address ILOM IP IP TCP/IP

    Subnetmask ILOM

    Gateway ILOM

    8 ILOM 157

  • 4. [Save] [Save] IP ILOM

    Web

    5. IP ILOM

    Web 1. ILOM Web

    2. [Configuration] --> [Serial Port][Serial Port Settings]

    8-4 [Serial Port Settings]

    3.

    158 Integrated Lights Out Manager 2.0 2007 10 A

  • Web ILOM 9600

    1. ILOM ILOM Web

    2. [Configuration] --> [Serial Port][Serial Port Settings]

    3. [Internal Serial Port Baud Rate] 0COM1 /dev/ttyS0

    BIOS ( 9600 )

    ILOM ILOM (9600 8N1 [8 1 ] )

    4. [External Serial Port Baud Rate] RJ-45

    5. [Save] [Cancel]

    Web HTTP HTTPS Web Web

    ILOM Web HTTP HTTPS HTTP HTTPS HTTPS HTTP HTTPS

    HTTPS

    1. ILOM ILOM Web

    2. [Configuration] --> [System Management Access] --> [Web Server][Web Server Settings]

    8 ILOM 159

  • 8-5 [Web Server Settings]

    3. HTTP HTTPS Web HTTP [Enabled]

    [Redirect HTTP Connection to HTTPS] HTTP HTTPS [Disabled] HTTP

    HTTPS [HTTPS Webserver] [Enabled] HTTPS Web

    HTTP [Redirect HTTP Connection to HTTPS] HTTPS ILOM Web CLI /SP/services/http /SP/services/https 150 CLI HTTP HTTPS Web

    4. HTTP HTTPS

    5. [Save]

    160 Integrated Lights Out Manager 2.0 2007 10 A

  • 9

    ILOM (IPMI)

    161 IPMI 162 ILOM IPMI 162 IPMItool 163 IPMI 164 IPMItool

    IPMI (IPMI) IPMI (FRU) ()IPMI

    IPMI IPMI

    ILOM IPMI v1.5 v2.0

    IPMI

    http://www.intel.com/design/servers/ipmi/spec.htm

    http://openipmi.sourceforge.net

    161

  • ILOM IPMIIPMI IPMI (BMC) ( IPMI )

    (SP) IPMI v2.0 IPMItool IPMI ILOM Web IPMI IPMI v1.5 v2.0 SP IPMI

    IPMItoolIPMItool (CLI) IPMI IPMItool IPMI IPMItool LAN IPMI IPMItoolhttp://ipmitool.sourceforge.net/

    IPMItool (SDR)

    (SEL) (FRU) LAN

    IPMItool

    http://ipmitool.sourceforge.net/manpage.html

    162 Integrated Lights Out Manager 2.0 2007 10 A

    http://ipmitool.sourceforge.net/http://ipmitool.sourceforge.net/manpage.html

  • IPMI ILOM IPMI (PET) SP IPMI PET (CMM)

    IPMI ILOM ILOM ILOM IP IPMI PET IPMI PET

    IPMI PET ILOM Minor Minor

    Major

    Critical

    Down Disabled ILOM

    134 ILOM Web 137 ILOM CLI

    ILOM CLI 137 CLI

    9 163

  • IPMItool IPMItool 10.8.136.165 ILOM IP ()

    $ ipmitool -H 10.8.136.165 -I lanplus -U root -P changeme sdr list

    /SYS/T_AMB | 24 degrees C | ok

    /RFM0/FAN1_SPEED | 7110 RPM | ok

    /RFM0/FAN2_SPEED | 5880 RPM | ok

    /RFM1/FAN1_SPEED | 5880 RPM | ok

    /RFM1/FAN2_SPEED | 6360 RPM | ok

    /RFM2/FAN1_SPEED | 5610 RPM | ok

    /RFM2/FAN2_SPEED | 6510 RPM | ok

    /RFM3/FAN1_SPEED | 6000 RPM | ok

    /RFM3/FAN2_SPEED | 7110 RPM | ok

    /RFM4/FAN1_SPEED | 6360 RPM | ok

    /RFM4/FAN2_SPEED | 5610 RPM | ok

    /RFM5/FAN1_SPEED | 5640 RPM | ok

    /RFM5/FAN2_SPEED | 6510 RPM | ok

    /RFM6/FAN1_SPEED | 6180 RPM | ok

    /RFM6/FAN2_SPEED | 6000 RPM | ok

    /RFM7/FAN1_SPEED | 6330 RPM | ok

    /RFM7/FAN2_SPEED | 6330 RPM | ok

    /RFM8/FAN1_SPEED | 6510 RPM | ok

    /RFM8/FAN2_SPEED | 5610 RPM | ok

    163

    164 Integrated Lights Out Manager 2.0 2007 10 A

  • $ ipmitool -H 10.8.136.165 -v -I lanplus -U root -P changeme sensor get /SYS/T_AMB

    Locating sensor record...

    Sensor ID : /SYS/T_AMB (0x8)

    Entity ID : 41.0

    Sensor Type (Analog) : Temperature

    Sensor Reading : 24 (+/- 0) degrees C

    Status : ok

    Lower Non-Recoverable : 0.000

    Lower Critical : 4.000

    Lower Non-Critical : 10.000

    Upper Non-Critical : 35.000

    Upper Critical : 40.000

    Upper Non-Recoverable : 45.000

    Assertions Enabled : lnc- lcr- lnr- unc+ ucr+ unr+

    Deassertions Enabled : lnc- lcr- lnr- unc+ ucr+ unr+

    $ ipmitool -H 10.8.136.165 -v -I lanplus -U root -P changeme chassis power on

    $ ipmitool -H 10.8.136.165 -v -I lanplus -U root -P changeme chassis power off

    9 165

  • $ ipmitool -H 10.8.136.165 -v -I lanplus -U root -P changeme chassis power cycle

    $ ipmitool -H 10.8.136.165 -v -I lanplus -U root -P changeme chassis power soft

    FRU $ ipmitool -H 10.8.136.165 -v -I lanplus -U root -P changeme fru print

    FRU Device Description : Builtin FRU Device (ID 0)

    Board Product : ASSY,ANDY,4SKT_PCI-E,BLADE

    Board Serial : 0000000-7001

    Board Part Number : 501-7738-01

    Board Extra : AXX_RevE_Blade

    Product Manufacturer : SUN MICROSYSTEMS

    Product Name : ILOM

    FRU Device Description : /SYS (ID 4)

    Chassis Type : Rack Mount Chassis

    Chassis Part Number : 541-0251-05

    Chassis Serial : 00:03:BA:CD:59:6F

    Board Product : ASSY,ANDY,4SKT_PCI-E,BLADE

    Board Serial : 0000000-7001

    Board Part Number : 501-7738-01

    Board Extra : AXX_RevE_Blade

    Product Manufacturer : SUN MICROSYSTEMS

    166 Integrated Lights Out Manager 2.0 2007 10 A

  • Product Name : SUN BLADE X8400 SERVER MODULE

    Product Part Number : 602-0000-00

    Product Serial : 0000000000

    Product Extra : 080020ffffffffffffff0003baf15c5a

    FRU Device Description : /P0 (ID 5)

    Product Manufacturer : ADVANCED MICRO DEVICES

    Product Part Number : 0F21

    Product Version : 2

    FRU Device Description : /P0/D0 (ID 6)

    Product Manufacturer : MICRON TECHNOLOGY

    Product Name : 1024MB DDR 400 (PC3200) ECC

    Product Part Number : 18VDDF12872Y-40BD3

    Product Version : 0300

    Product Serial : D50209DA

    Product Extra : 0190

    Product Extra : 0400

    FRU Device Description : /P0/D1 (ID 7)

    Product Manufacturer : MICRON TECHNOLOGY

    Product Name : 1024MB DDR 400 (PC3200) ECC

    Product Part Number : 18VDDF12872Y-40BD3

    Product Version : 0300

    Product Serial : D50209DE

    Product Extra : 0190

    Product Extra : 0400

    9 167

  • IPMI $ ipmitool -H 10.8.136.165 -I lanplus -U root -P changeme sel list

    100 | Pre-Init Time-stamp | Power Unit #0x78 | State Deasserted

    200 | Pre-Init Time-stamp | Power Supply #0xa2 | Predictive Failure Asserted

    300 | Pre-Init Time-stamp | Power Supply #0xba | Predictive Failure Asserted

    400 | Pre-Init Time-stamp | Power Supply #0xc0 | Predictive Failure Asserted

    500 | Pre-Init Time-stamp | Power Supply #0xb4 | Predictive Failure Asserted

    600 | 04/05/2007 | 12:03:24 | Power Supply #0xa3 | Predictive Failure Deasserted

    700 | 04/05/2007 | 12:03:25 | Power Supply #0xaa | Predictive Failure Deasserted

    800 | 04/05/2007 | 12:03:25 | Power Supply #0xbc | Predictive Failure Deasserted

    900 | 04/05/2007 | 12:03:26 | Power Supply #0xa2 | Predictive Failure Asserted

    a00 | 04/05/2007 | 12:03:26 | Power Supply #0xa8 | Predictive Failure Deasserted

    b00 | 04/05/2007 | 12:03:26 | Power Supply #0xb6 | Predictive Failure Deasserted

    c00 | 04/05/2007 | 12:03:26 | Power Supply #0xbb | Predictive Failure Deasserted

    d00 | 04/05/2007 | 12:03:26 | Power Supply #0xc2 | Predictive Failure Deasserted

    e00 | 04/05/2007 | 12:03:27 | Power Supply #0xb0 | Predictive Failure Deasserted

    f00 | 04/05/2007 | 12:03:27 | Power Supply #0xb5 | Predictive Failure Deasserted

    1000 | 04/05/2007 | 12:03:27 | Power Supply #0xba | Predictive Failure Asserted

    1100 | 04/05/2007 | 12:03:27 | Power Supply #0xc0 | Predictive Failure Asserted

    1200 | 04/05/2007 | 12:03:28 | Power Supply #0xa9 | Predictive Failure Deasserted

    1300 | 04/05/2007 | 12:03:28 | Power Supply #0xae | Predictive Failure Deasserted

    1400 | 04/05/2007 | 12:03:28 | Power Supply #0xb4 | Predictive Failure Asserted

    1500 | 04/05/2007 | 12:03:28 | Power Supply #0xbe | Predictive Failure Deasserted

    168 Integrated Lights Out Manager 2.0 2007 10 A

  • 10

    ILOM (SNMP)SNMP

    170 SNMP 170 SNMP 171 SNMP 171 SNMP 172 CLI SNMP

    172 CLI SNMP 172 CLI SNMP 173 CLI SNMP 173 CLI SNMP 173 CLI SNMP 175 CLI SNMP

    176 Web SNMP 176 Web SNMP 178 Web SNMP 179 Web SNMP 180 Web SNMP 180 Web SNMP 181 Web SNMP

    181 SNMP 182 SNMP 184 snmpget snmpwalk net-snmp 185 snmpset 185 snmptrapd

    /SP/ /CMM/

    169

  • SNMP (SNMP) () SNMP () SNMP Web SNMP (UDP) IP SNMP

    ILOM SNMP 12c 3 SNMP v3 SNMP v1 v2c SNMP v3

    SNMP SNMP SNMP net-SNMP

    http://net-snmp.sourceforge.net/

    SNMP

    Get GetNext GetResponse Set Trap

    SNMP SNMP

    () SNMP ( ILOM SP)

    SNMP

    SNMP ILOM SNMP ILOM SNMP

    170 Integrated Lights Out Manager 2.0 2007 10 A

    http://net-snmp.sourceforge.net/

  • SNMP SNMP (MIB)MIB MIB SNMP MIB MIB

    SNMP MIB ILOM SNMPv2 MIB (RFC1907) snmp SNMP-FRAMEWORK-MIB (RFC2271.txt) SNMP-USER-BASED-MIB (RFC 2574) SNMP-MPD-MIB (RFC 2572)

    ENTITY-MIB (RFC2737) entPhysicalTable SUN-PLATFORM-MIB

    MIB SUN-ILOM-CONTROL-MIB

    MIB SP CMM SUN-HW-TRAP-MIB

    MIB SP CMM SUN-ILOM-PET-MIB

    MIB SP IPMI (PET) PET 131

    SNMP ILOM 15 ILOM ILOM IPMI PET SNMP

    ILOM IP SNMP SNMP

    ILOM SNMP SNMP SNMP

    10 171

  • MIB SNMP

    ILOM SNMP

    161 SNMP 162

    CLI SNMP ILOM (CLI) SNMP

    ILOM CLI [Set Requests] SNMP

    CLI SNMP 1. ILOM CLI

    2. SNMP v3

    create /SP/services/snmp/users/username authenticationpassword=password

    CLI SNMP 1. ILOM CLI

    2. SNMP v3

    edit /SP/services/snmp/users/username authenticationpassword=password

    SNMP authenticationpassword

    172 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI SNMP 1. ILOM CLI

    2. SNMP v3

    delete /SP/services/snmp/users/username

    CLI SNMP 1. ILOM CLI

    2. SNMP v1/v2c

    create /SP/services/snmp/communities/communityname

    CLI SNMP 1. ILOM CLI

    2. SNMP v1/v2c

    delete /SP/services/snmp/communities/communityname

    10 173

  • SNMP

    a1 privacyprotocol DES

    -> set /SP/services/snmp/users/al privacyprotocol=DES privacypassword=password authenticationprotocol=SHA authenticationpassword=password

    -> set /SP/services/snmp/users/al privacyprotocol=DES

    SNMP privacy authentication

    10-1 SNMP

    /SP/services/snmp/communities/communityname

    permissions ro|rw ro

    /SP/services/snmp/users/username

    authenticationprotocol

    authenticationpassword*

    permissions

    privacyprotocol

    privacypassword*

    MD5|SHA

    ro|rw

    none|DES

    MD5

    ()ro

    none

    ()

    /SP/services/snmp engineid = none

    port = 161

    sets = enabled

    v1 = disabled

    v2c = disabled

    v3 = disabled

    enabled|disabled

    enabled|disabled

    enabled|disabled

    enabled|disabled

    ()161

    disabled

    disabled

    disabled

    enabled

    * privacyprotocol none privacypassword authenticationpassword ( SNMP v3)

    174 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI SNMP SNMP

    1. ILOM CLI

    2. show

    -> show

    /SP/alertmgmt/rules/1

    Targets:

    Properties:

    community_or_username = publicdestination = 0.0.0.0level = disablesnmp_version = 1type = snmptrap

    Commands:

    cdsetshow

    3. /SP/alertmgmt/rules/snmp -> cd /SP/alertmgmt/rules/snmp

    4. SNMP ( 1 15)

    -> cd 4

    5. set

    -> set type=snmptrap level=critical destination= snmp_version=2c community_or_username=public

    10 175

  • Web SNMP ILOM Web SNMP

    Web SNMP SNMP

    1. ILOM Web ILOM SNMP

    2. [Configuration] --> [System Management Access] --> [SNMP][SNMP Settings]

    10-1 [SNMP Settings]

    176 Integrated Lights Out Manager 2.0 2007 10 A

  • 3. [Port]

    4. [Set Requests] [Set Requests] [Set Requests] SNMP

    5. SNMP v1v2c v3 SNMP v3 v1v2c v3

    6. [Save]

    SNMP 10-2

    10-2 SNMP

    10 177

  • Web SNMP SNMP v3

    1. ILOM Web ILOM SNMP

    2. [Configuration] --> [System Management Access] --> [SNMP][SNMP Settings]

    3. [Users] [SNMP Users]

    4. [SNMP Users] [Add] [Edit] 10-3 [Add] [Edit]

    10-3 [Add SNMP User]

    5. [User Name] 35

    6. [Authentication Protocol] 5 ([MD5]) ([SHA])

    178 Integrated Lights Out Manager 2.0 2007 10 A

  • 7. [Authentication Password] 8 16

    8. [Confirm Password]

    9. [Permission] ([ro]) ([rw])

    10. [Privacy Protocol] [DES] [None]

    11. [Privacy Password] 8 16

    12. [Confirm Password]

    13. [Save]

    Web SNMP SNMP v3

    1. ILOM Web SNMP

    2. [Configuration] --> [System Management Access] --> [SNMP][SNMP Settings]

    3. [Users] [SNMP Users]

    4. SNMP

    5. [SNMP Users] [Delete]

    6. [OK]

    10 179

  • Web SNMP SNMP v1 v2c

    1. ILOM Web SNMP

    2. [Configuration] --> [System Management Access] --> [SNMP][SNMP Settings]

    3. [Communities] [SNMP Communities]

    4. [SNMP Communities] [Add] [Edit] [Add] [Edit]

    5. [Community Name]

    35

    6. [Permission] ([ro]) ([rw])

    7. [Save]

    Web SNMP SNMP v1 v2c

    1. ILOM Web SNMP

    2. [Configuration] --> [System Management Access] --> [SNMP][SNMP Settings]

    3. [Communities] [SNMP Communities]

    4. SNMP

    5. [Delete]

    6. [OK] SNMP

    180 Integrated Lights Out Manager 2.0 2007 10 A

  • Web SNMP SNMP

    1. ILOM Web SNMP

    2. [Configuration] --> [Alert Management][Alert Settings]

    3. [Actions] [Edit][Create or Modify Alert]

    4.

    5. [Type] [SNMP Trap]

    6. SNMP IP SNMP

    7. [Save]

    SNMP net-snmp ILOM SP SNMP

    net-snmp (5.2.1 )

    http://net-snmp.sourceforge.net/

    net-snmp ILOM MIB (SNMPv2-MIBSNMP-FRAMEWORK-MIB ENTITY-MIB) SUN-PLATFORM-MIB.mibSUN-ILOM-CONTROL-MIB.mibSUN-HW-TRAP-MIB.mib SUN-ILOM-PET-MIB.mib net-snmp MIB URL

    http://net-snmp.sourceforge.net/wiki/index.php/TUT:Using_and_loading_MIBS

    10 181

    http://net-snmp.sourceforge.net/wiki/index.php/TUT:Using_and_loading_MIBShttp://net-snmp.sourceforge.net/wiki/index.php/TUT:Using_and_loading_MIBS

  • SNMP SP CMM SNMP

    1. /SP/services/snmp

    -> cd /SP/services/snmp

    2. show SNMP

    -> show

    /SP/services/snmp

    Targets:

    communitiesusers

    Properties:

    engineid = noneport = 161sets = disabledv1 = disabledv2c = disabledv3 = enabled

    Commands:

    cdsetshow

    3. SNMP v2c enabled

    -> set v2c=enabled

    sets enabled-> set sets=enabled

    182 Integrated Lights Out Manager 2.0 2007 10 A

  • 4. -> show communities

    /SP/services/snmp/communities

    Targets:

    public

    Properties:

    Commands:

    cdcreatedeleteshow

    5.

    -> show communities/public

    /SP/services/snmp/communities/public

    Targets:

    Properties:

    permission = ro

    Commands:

    cdsetshow

    6.

    -> create communities/private permission=rw

    10 183

  • snmpget snmpwalk net-snmp

    1. snmpget

    $ snmpget -v 2c -c public -m ALL sysObjectID.0 sysUpTime.0 sysLocation.0

    SNMPv2-MIB::sysObjectID.0 =

    OID:SUN-FIRE-SMI-MIB::sunBladeX8400ServerModule

    SNMPv2-MIB::sysUpTime.0 = Timeticks: (17523) 0:02:55.23

    SNMPv2-MIB::sysLocation.0 = STRING:

    2. snmpwalk

    $ snmpwalk -v 2c -c public -m ALL entPhysicalName

    ENTITY-MIB::entPhysicalName.1 = STRING: /SYS

    ENTITY-MIB::entPhysicalName.2 = STRING: /SYS/OK2RM

    ENTITY-MIB::entPhysicalName.3 = STRING: /SYS/SERVICE

    ENTITY-MIB::entPhysicalName.4 = STRING: /SYS/OK

    ENTITY-MIB::entPhysicalName.5 = STRING: /SYS/LOCATE

    ENTITY-MIB::entPhysicalName.6 = STRING: /SYS/LOCATE_BTN

    ENTITY-MIB::entPhysicalName.7 = STRING: /SYS/POWER_BTN

    ENTITY-MIB::entPhysicalName.8 = STRING: /SYS/T_AMB

    ENTITY-MIB::entPhysicalName.9 = STRING: /SYS/P0

    184 Integrated Lights Out Manager 2.0 2007 10 A

  • snmpset snmpset

    $ snmpset -v 2c -c private -m ALL sysLocation.0 s ""

    SNMPv2-MIB::sysLocation.0 = STRING: ILOM Dev Lab

    snmptrapd snmptrapd

    $ /usr/sbin/snmptrapd -m ALL -f -Lo

    SNMP

    2007-05-21 08:46:41 ban3c9sp4 [10.8.136.94]:

    SNMPv2-MIB::sysUpTime.0 = Timeticks: (1418) 0:00:14.18

    SNMPv2-MIB::snmpTrapOID.0 = OID:

    SUN-HW-TRAP-MIB::sunHwTrapPowerSupplyError

    SUN-HW-TRAP-MIB::sunHwTrapSystemIdentifier.0 = STRING:

    SUN-HW-TRAP-MIB::sunHwTrapChassisId.0 = STRING:

    ban6c4::0000000000 SUN-HW-TRAP-MIB::sunHwTrapProductName.0

    = STRING:SUN-HW-TRAP-MIB::sunHwTrapComponentName.0 =

    STRING:/PS3/FAN_ERR

    SUN-HW-TRAP-MIB::sunHwTrapAdditionalInfo.0 = STRING: Predictive

    Failure Asserted SUN-HW-TRAP-MIB::sunHwTrapAssocObjectId.0 =

    OID:SNMPv2-SMI::zeroDotZero

    10 185

  • 186 Integrated Lights Out Manager 2.0 2007 10 A

  • 11

    ILOM ILOM ILOM x64 BIOSOpenBoot PROM SPARC Hypervisor

    187 188 ILOM

    188 CLI ILOM 189 CLI ILOM 189 Web ILOM 190 Web ILOM 191 ILOM SP

    ILOM ILOM

    5 ILOM ILOM

    ILOM

    187

  • ILOM 1.

    2. TFTP CLI Web

    3.

    4. CLI Web (SP) / (CMM)

    5.

    CLI ILOM 1. Shell

    2. version

    SP firmware #.#.#.#SP firmware build number: #####SP firmware date: Fri Apr 27 14:03:21 EDT 2007SP filesystem version: #.#.##

    188 Integrated Lights Out Manager 2.0 2007 10 A

  • CLI ILOM 1.

    2. CLI ILOM ->load -source tftpURL

    Web ILOM 1.

    2. [User Mangement] --> [Version]

    -> load -source tftp://xxx.xxx.xxx.xxx/filename.pkg

    NOTE: A firmware upgrade will cause the server and ILOM to be reset. It is recommended that a clean shutdown of the server be done prior to the upgrade procedure. An upgrade takes about 6 minutes to complete. ILOM will enter a special mode to load new firmware. No other tasks can be performed in ILOM until the firmware upgrade is complete and ILOM is reset.

    Are you sure you want to load the specified file (y/n)? yDo you want to preserve the configuration (y/n)? y. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Preserving configuration. Please wait.Done preserving configuration.

    Firmware update is complete.ILOM will now be restarted with the new firmware.

    11 ILOM 189

  • Web ILOM 1.

    2. [Maintenance] --> [Firmware Upgrade][Firmware Upgrade]

    3. [Enter Upgrade Mode]

    4. [OK] [Cancel] ILOM

    5. [Select Image File to Upload] ILOM [Browse] .pkg .ima .pkg

    11-1 [Firmware Upgrade]

    6. [Upload] [Cancel] SP CMM 1

    7. [Verify Firmware Image] [OK]

    8. [Preserve Configuration] ILOM