integrated lights out manager (ilom) supplement for sun

38
Sun Microsystems, Inc. www.sun.com Submit comments about this document at: http://www.sun.com/hwdocs/feedback Integrated Lights Out Manager (ILOM) Supplement for Sun Fire™ X4100/X4100 M2 and X4200/X4200 M2 Servers Part No. 819-5464-16 February 2010, Revision A

Upload: others

Post on 24-Mar-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sun Microsystems, Inc.www.sun.com

Submit comments about this document at: http://www.sun.com/hwdocs/feedback

Integrated Lights Out Manager (ILOM)Supplement for Sun Fire™ X4100/X4100 M2

and X4200/X4200 M2 Servers

Part No. 819-5464-16February 2010, Revision A

Page 2: Integrated Lights Out Manager (ILOM) Supplement for Sun

Copyright © 2010 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.

Sun Microsystems, Inc. has intellectual property rights relating to technology embodied in the product that is described in this document. Inparticular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed athttp://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S. and in other countries.

This distribution may include materials developed by third parties.

Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark inthe U.S. and in other countries, exclusively licensed through X/Open Company, Ltd.

Sun, Sun Microsystems, the Sun logo, Java, Netra, Solaris, Sun Ray, Sun Fire Servers, Sun Fire X4100 Server, X4100 M2 Server, X4200 Server,X4200 M2 Server, SunVTS, the Java Coffee Cup logo, the Solaris logo, Sun and Java are trademarks or registered trademarks of SunMicrosystems, Inc. in the U.S. and other countries.

UNIX is a registered trademark in the United States and other countries, exclusively licensed through X/Open Company, Ltd. AMD OpteronAMD, Opteron, the AMD logo, the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices.

The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledgesthe pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sunholds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun's licensees who implement OPENLOOK GUIs and otherwise comply with Sun's written license agreements.

Use of any spare or replacement CPUs is limited to repair or one-for-one replacement of CPUs in products exported in compliance with U.S.export laws. Use of CPUs as product upgrades unless authorized by the U.S. Government is strictly prohibited.

DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT,ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.

Copyright © 2010 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, Etats-Unis. Tous droits réservés.

Sun Microsystems, Inc. détient les droits de propriété intellectuels relatifs à la technologie incorporée dans le produit qui est décrit dans cedocument. En particulier, et ce sans limitation, ces droits de propriété intellectuelle peuvent inclure un ou plus des brevets américains listés àl'adresse http://www.sun.com/patents et un ou les brevets supplémentaires ou les applications de brevet en attente aux Etats - Unis et dansles autres pays.

Cette distribution peut inclure des éléments développés par des tiers.

Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l'Université de Californie. UNIX est une marquedéposée aux Etats-Unis et dans d'autres pays et licenciée exclusivement par X/Open Company, Ltd.

Sun, Sun Microsystems, le logo Sun, Java, Netra, Solaris, Sun Ray, Sun Fire Servers, Sun Fire X4100 Server, X4100 M2 Server, X4200 Server, X4200M2 Server, SunVTS, le logo Java Coffee Cup, le logo Solaris, Sun et Java sont des marques de fabrique ou des marques déposées de SunMicrosystems, Inc. aux Etats-Unis et dans d'autres pays.

UNIX est une marque enregistree aux Etats-Unis et dans d'autres pays et licenciée exclusivement par X/Open Company Ltd. AMD Opteron estune marque déposée de Advanced Micro Devices, Inc.

L'interface d'utilisation graphique OPEN LOOK et Sun(TM) a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sunreconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d'utilisation visuelle ou graphiquepour l'industrie de l'informatique. Sun détient une license non exclusive de Xerox sur l'interface d'utilisation graphique Xerox, cette licencecouvrant également les licenciés de Sun qui mettent en place l'interface d'utilisation graphique OPEN LOOK et qui, en outre, se conforment auxlicences écrites de Sun.

L'utilisation de pieces detachees ou d'unites centrales de remplacement est limitee aux reparations ou a l'echange standard d'unites centralespour les produits exportes, conformement a la legislation americaine en matiere d'exportation. Sauf autorisation par les autorites des Etats-Unis, l'utilisation d'unites centrales pour proceder a des mises a jour de produits est rigoureusement interdite.

LA DOCUMENTATION EST FOURNIE "EN L'ETAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSESOU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENTTOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L'APTITUDE A UNE UTILISATION PARTICULIERE OU AL'ABSENCE DE CONTREFACON.

Page 3: Integrated Lights Out Manager (ILOM) Supplement for Sun

Contents

How to Reset the Service Processor and BIOS Passwords 1

Service Processor Lost Password Recovery Procedure (6881237) 2

▼ To Recover a Lost Password Using the default User Account 2

Hardware Information 3

Server Locator Indicator 3

Hardware Port Locations 3

Sensors 5

Temperature, Voltage, and Fan Sensor Readings 6

List of Sensors 7

iii

Page 4: Integrated Lights Out Manager (ILOM) Supplement for Sun

iv ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 5: Integrated Lights Out Manager (ILOM) Supplement for Sun

Introduction

This supplement contains information specific to the products listed on the titlepage. For general ILOM descriptions, refer to Integrated Lights Out Manager (ILOM)Administration Guide.

This document provides information about the following topics:

■ “How to Reset the Service Processor and BIOS Passwords” on page 1

■ “Service Processor Lost Password Recovery Procedure (6881237)” on page 2

■ “Hardware Information” on page 3

■ “Sensors” on page 5

Note – The information in this book applies to all products listed on the title page,except where otherwise noted.

How to Reset the Service Processor andBIOS PasswordsYou can reset the administration password, and clear the BIOS password, usingjumper procedure described in the Sun Fire X4100 and Sun Fire X4200 Server ServiceManual, 819-1157.

1

Page 6: Integrated Lights Out Manager (ILOM) Supplement for Sun

■ The administration (root) password becomes changeme.

■ The BIOS password is cleared, so that when you attempt to access the BIOS setuputility, it does not prompt for a password.

Service Processor Lost PasswordRecovery Procedure (6881237)In ILOM 3.0, the root account—which was used for administrative tasks in ILOM2.0—has been removed and the default user account is used for initial login,creation of user accounts, and server configuration. After those tasks are performed,the default user account’s access is limited to the CLI on the SP console. Therefore,all subsequent user account changes (creations and modifications) and configurationchanges should be done using specific user accounts. This requirement enablesaccountability to be traced to individual users who have access to specific accounts.

As mentioned, once you login to the default user account, subsequent access tothis account is restricted to the CLI on the SP console, which connects through theserial management port. Additionally, by default, the SP requires that a “physicalpresence” switch be pressed on the server before the SP console can be used for thispurpose. This requirement is there for security reasons as it prevents access to thedefault user account from a remote location, that is, you must have physical accessto the server to use this account.

One of the uses of the default user account is lost password recovery. It is meant tobe used when you cannot access the account for which the password was lost byusing a different user account. User accounts assigned the user (u) role can be usedto change and reset passwords on other user accounts. If there are no user accountsthat have the ability to reset passwords, you can use the CLI on the SP console to login to the default user account.

▼ To Recover a Lost Password Using the defaultUser Account1. Connect a serial cable from the RJ-45 SER MGT port on the server’s back panel

to a terminal device.

For instructions, refer to the Sun Fire X4100/X4100 M2 and X4200/X4200 M2Servers Installation Guide (820-1155).

2. Ensure that the server is powered on.

The localhost login prompt appears.

2 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 7: Integrated Lights Out Manager (ILOM) Supplement for Sun

3. Log in to the default user account. Type:

localhost login: default

4. Press the Locator button once.

This Locator button is on the front of the server.

5. Press the Enter key on the terminal device.

The SP displays the Password prompt.

6. Enter the password for the default user account.

The default user account password is the product serial number and it cannotbe changed. The product serial number is printed on the server hardware or onthe product purchase documentation.

Once you have successfully logged in, the SP displays its default CLI commandprompt: ->

7. You can now use the default user account to reset the passwords for useraccounts for which passwords have been lost.

For instructions on how to use the CLI to reset user passwords, see the SunIntegrated Lights Out Manager 3.0 User’s Guide (820-4597).

Hardware InformationThis section provides information about the system hardware.

Server Locator IndicatorThis is a pair of small lights that you turn on to help you identify a specific serveramong many in a data center. One light is positioned on the front of the server in theupper-left corner, and the other light is on the back of the server in the upper-centersection.

Hardware Port LocationsThe ILOM communicates through the server’s serial management port and througha dedicated Ethernet port.

FIGURE 1 shows the location of the serial port and the service processor Ethernet porton Sun Fire X4100/Sun Fire X4100 M2 servers.

Introduction 3

Page 8: Integrated Lights Out Manager (ILOM) Supplement for Sun

FIGURE 1 Sun Fire X4100/X4100 M2 Rear Panel with Service Processor Port Locations

FIGURE 2 shows the location of the serial port and the service processor Ethernet porton Sun Fire X4200/X4200 M2 servers.

FIGURE 2 Sun Fire X4200/X4200 M2 Rear Panel with Service Processor Port Locations

Serial Port (Left) and shows enlarged diagrams of the serial port and the serviceprocessor Ethernet port.

FIGURE 3 Service Processor Ethernet Port (Right)

Serial port

Service processor Ethernet port

NET

MG

T

Serial port Service processor Ethernet port

4 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 9: Integrated Lights Out Manager (ILOM) Supplement for Sun

SensorsThese servers include a number of sensors that generate entries in the system eventlog (SEL) when the sensor crosses a threshold. Many of these readings are used toadjust the fan speeds and perform other actions, such as illuminating LEDs andpowering off the chassis.

These sensors can also be configured to generate IPMI PET traps, as described in theAdministration Guide.

Caution – Do not use any interface other than the ILOM CLI or WebGUI to alter thestate or configuration of any sensor or LED. Doing so could void your warranty.

This section describes the sensors and provides details about their operation.

Introduction 5

Page 10: Integrated Lights Out Manager (ILOM) Supplement for Sun

Temperature, Voltage, and Fan Sensor ReadingsThe system monitors six temperature sensors. They all generate IPMI events that arelogged in to the system event log (SEL) when an upper threshold is exceeded. Threeof these sensor readings are used to adjust the fan speeds and perform other actions,such as illuminating LEDs and powering off the chassis; these are described inTables 1 and 2 follows:

There are three other temperature sensors:

■ I/O board ambient temperature (io.t_amb)

■ Motherboard ambient temperature (mb.t_amb)

■ Power distribution board ambient temperature (pdb.t_amb)

TABLE 1 Front Panel Ambient Temperature (fp.t_amb)

Temperature (degrees C)

Sun Fire X4100/X4200 Sun Fire X4100/X4200 M2

Upper noncritical 30 30

Upper critical 35 35

Upper nonrecoverable 40 45

TABLE 2 CPU Die Temperatures (p0.t_core and p1.t_core)

Temperature (degrees C)

Sun Fire X4100/X4200 Sun Fire X4100/X4200 M2

Upper noncritical 55 62

Upper critical 65 67

Upper nonrecoverable 75 75

6 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 11: Integrated Lights Out Manager (ILOM) Supplement for Sun

List of SensorsTABLE 3 lists the sensors. TABLE 4 provides more detailed information aboutindividual sensors.

TABLE 3 List of Sensors

Sensor Name Data Status

sys.id 0x10 OK

sys.intsw 0x00 OK

sys.psfail 0x01 OK

sys.tempfail 0x01 OK

sys.fanfail 0x01 OK

mb.t_amb 25 degrees C OK

mb.v_bat 2.72 Volts OK

mb.v_+3v3stby 3.10 Volts OK

mb.v_+3v3 3.34 Volts OK

mb.v_+5v 4.99 Volts OK

mb.v_+12v 11.84 Volts OK

mb.v_-12v -12.28 Volts OK

mb.v_+1v2core 1.22 Volts OK

bp.power 0x02 OK

bp.locate 0x02 OK

bp.locate.btn 0x01 OK

bp.alert 0x01 OK

fp.prsnt 0x02 OK

fp.t_amb 23 degrees C OK

fp.usbfail 0x01 OK

fp.power 0x02 OK

fp.locate 0x01 OK

fp.locate.btn 0x01 OK

fp.alert 0x01 OK

fp.ledbd.prsnt 0x02 OK

pdb.t_amb 24 degrees C OK

Introduction 7

Page 12: Integrated Lights Out Manager (ILOM) Supplement for Sun

ps0.prsnt 0x02 OK

ps0.pwrok 0x02 OK

ps0.vinok 0x02 OK

ps1.prsnt 0x01 OK

ps1.pwrok Not Readable ns

ps1.vinok Not Readable ns

io.t_amb 22 degrees C OK

io.id0.prsnt 0x01 OK

io.id1.prsnt 0x02 OK

io.f0.prsnt 0x02 OK

io.f0.speed 4000 RPM OK

io.f0.fail 0x01 OK

io.hdd0.fail 0x01 OK

io.hdd1.fail 0x01 OK

io.hdd2.fail 0x01 OK

io.hdd3.fail 0x01 OK

p0.t_core 40 degrees C OK

p0.v_vdd 1.44 Volts OK

p0.v_vddio 2.63 Volts OK

p0.v_vtt 1.31 Volts OK

p0.fail 0x02 OK

p0.d0.fail 0x01 OK

p0.d1.fail 0x01 OK

p0.d2.fail 0x01 OK

p0.d3.fail 0x01 OK

p1.t_core 44 degrees C OK

p1.v_vdd 1.45 Volts OK

p1.v_vddio 2.63 Volts OK

p1.v_vtt 1.31 Volts OK

p1.fail 0x02 OK

TABLE 3 List of Sensors (Continued)

Sensor Name Data Status

8 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 13: Integrated Lights Out Manager (ILOM) Supplement for Sun

p1.d0.fail 0x01 OK

p1.d1.fail 0x01 OK

p1.d2.fail 0x01 OK

p1.d3.fail 0x01 OK

ft0.fm0.fail 0x01 OK

ft0.fm1.fail 0x01 OK

ft0.fm2.fail 0x01 OK

ft1.fm0.fail 0x01 OK

ft1.fm1.fail 0x01 OK

ft1.fm2.fail 0x01 OK

ft0.fm0.prsnt 0x02 OK

ft0.fm1.prsnt 0x02 OK

ft0.fm2.prsnt 0x02 OK

ft1.fm0.prsnt 0x02 OK

ft1.fm1.prsnt 0x02 OK

ft1.fm2.prsnt 0x02 OK

ft0.fm0.f0.speed 11000 RPM OK

ft0.fm1.f0.speed 11000 RPM OK

ft0.fm2.f0.speed 12000 RPM OK

ft1.fm0.f0.speed 12000 RPM OK

ft1.fm1.f0.speed 11000 RPM OK

ft1.fm2.f0.speed 12000 RPM OK

TABLE 3 List of Sensors (Continued)

Sensor Name Data Status

Introduction 9

Page 14: Integrated Lights Out Manager (ILOM) Supplement for Sun

TABLE 4 provides detailed information about individual sensors.

TABLE 4 Sensor Details

Sensor Data

Sensor ID sys.id (0x0)

Entity ID 23.0 (System Chassis)

Sensor Type (Discrete) Chassis

States Asserted Digital State

[State Deasserted]

Sensor ID sys.intsw (0x1)

Entity ID 23.0 (System Chassis)

Sensor Type (Discrete) Physical Security

Assertions Enabled Physical Security

[General Chassis intrusion]

Sensor ID sys.psfail (0x2)

Entity ID 23.0 (System Chassis)

Sensor Type (Discrete) Power Supply

States Asserted Digital State

[Predictive Failure Deasserted]

Sensor ID sys.tempfail (0x3)

Entity ID 23.0 (System Chassis)

Sensor Type (Discrete) Temperature

States Asserted Digital State

[Predictive Failure Deasserted]

Sensor ID sys.fanfail (0x4)

Entity ID 23.0 (System Chassis)

Sensor Type (Discrete) Fan

States Asserted Digital State

[Predictive Failure Deasserted]

10 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 15: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID mb.t_amb (0x5)

Type Temperature

Class Threshold Sensor

Value 19.000 degree C

Upper_nonrecov_threshold 80.000 degree C

Upper_critical_threshold 75.000 degree C

Upper_noncritical_threshold 70.000 degree C

Lower_noncritical_threshold N/A

Lower_critical_threshold N/A

Lower_nonrecov_threshold N/A

Sensor ID mb.v_bat (0x6)

Type Voltage

Class Threshold Sensor

Value 2.855 Volts

Upper_nonrecov_threshold 3.697 Volts

Upper_critical_threshold 3.510 Volts

Upper_noncritical_threshold 3.307 Volts

Lower_noncritical_threshold 2.621 Volts

Lower_critical_threshold 2.527 Volts

Lower_nonrecov_threshold 2.340 Volts

Sensor ID mb.v_+3v3stby (0x7)

Entity ID 7.0 (System Board)

Sensor Type (Analog) Voltage

Sensor Reading 3.114 (+/- 0) Volts

Status OK

Upper nonrecoverable 3.996

Upper critical 3.789

Upper noncritical 3.598

Lower nonrecoverable 2.595

Lower critical 2.785

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 11

Page 16: Integrated Lights Out Manager (ILOM) Supplement for Sun

Lower noncritical 2.993

Positive Hysteresis 0.087

Negative Hysteresis 0.087

Minimum sensor range Unspecified

Maximum sensor range Unspecified

Event Message Control Per-threshold

Readable Thresholds lnr lcr lnc unc ucr unr

Settable Thresholds lnr lcr lnc unc ucr unr

Threshold Read Mask lnr lcr lnc unc ucr unr

Assertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Deassertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Sensor ID mb.v_+3v3 (0x8)

Entity ID 7.0 (System Board)

Sensor Type (Analog) Voltage

Sensor Reading 3.339 (+/- 0) Volts

Status OK

Upper nonrecoverable 3.996

Upper critical 3.789

Upper noncritical 3.598

Lower nonrecoverable 2.595

Lower critical 2.785

Lower noncritical 2.993

Positive Hysteresis 0.087

Negative Hysteresis 0.087

Minimum sensor range Unspecified

Maximum sensor range Unspecified

Event Message Control Per-threshold

Readable Thresholds lnr lcr lnc unc ucr unr

Settable Thresholds lnr lcr lnc unc ucr unr

Threshold Read Mask lnr lcr lnc unc ucr unr

TABLE 4 Sensor Details (Continued)

Sensor Data

12 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 17: Integrated Lights Out Manager (ILOM) Supplement for Sun

Assertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Deassertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Sensor ID mb.v_+5v (0x9)

Entity ID 7.0 (System Board)

Sensor Type (Analog) Voltage

Sensor Reading 4.992 (+/- 0) Volts

Status OK

Upper nonrecoverable 6.500

Upper critical 5.980

Upper noncritical 5.486

Lower nonrecoverable 3.484

Lower critical 3.978

Lower noncritical 4.498

Positive Hysteresis 0.078

Negative Hysteresis 0.078

Minimum sensor range Unspecified

Maximum sensor range Unspecified

Event Message Control Per-threshold

Readable Thresholds lnr lcr lnc unc ucr unr

Settable Thresholds lnr lcr lnc unc ucr unr

Threshold Read Mask lnr lcr lnc unc ucr unr

Assertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Deassertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 13

Page 18: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID mb.v_+12v (0xa)

Entity ID 7.0 (System Board)

Sensor Type (Analog) Voltage

Sensor Reading 11.844 (+/- 0) Volts

Status OK

Upper nonrecoverable 14.994

Upper critical 13.986

Upper noncritical 12.978

Lower nonrecoverable 8.946

Lower critical 9.954

Lower noncritical 10.962

Positive Hysteresis 0.063

Negative Hysteresis 0.063

Minimum sensor range Unspecified

Maximum sensor range Unspecified

Event Message Control Per-threshold

Readable Thresholds lnr lcr lnc unc ucr unr

Settable Thresholds lnr lcr lnc unc ucr unr

Threshold Read Mask lnr lcr lnc unc ucr unr

Assertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Deassertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

TABLE 4 Sensor Details (Continued)

Sensor Data

14 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 19: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID mb.v_-12v (0xb)

Entity ID 7.0 (System Board)

Sensor Type (Analog) Voltage

Sensor Reading -12.277 (+/- -16.000) Volts

Status OK

Upper nonrecoverable -9.065

Upper critical -10.014

Upper noncritical -11.036

Lower nonrecoverable -15.051

Lower critical -14.029

Lower noncritical -13.007

Positive Hysteresis 0.133

Negative Hysteresis 0.133

Minimum sensor range Unspecified

Maximum sensor range Unspecified

Event Message Control Per-threshold

Readable Thresholds lnr lcr lnc unc ucr unr

Settable Thresholds lnr lcr lnc unc ucr unr

Threshold Read Mask lnr lcr lnc unc ucr unr

Assertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Deassertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 15

Page 20: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID mb.v_+1v2core (0xe)

Entity ID 7.0 (System Board)

Sensor Type (Analog) Voltage

Sensor Reading 1.220 (+/- 0) Volts

Status OK

Upper nonrecoverable 1.900

Upper critical 1.700

Upper noncritical 1.500

Lower nonrecoverable 0.600

Lower critical 0.800

Lower noncritical 1.000

Positive Hysteresis 0.100

Negative Hysteresis 0.100

Minimum sensor range Unspecified

Maximum sensor range Unspecified

Event Message Control Per-threshold

Readable Thresholds lnr lcr lnc unc ucr unr

Settable Thresholds lnr lcr lnc unc ucr unr

Threshold Read Mask lnr lcr lnc unc ucr unr

Assertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Deassertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

TABLE 4 Sensor Details (Continued)

Sensor Data

16 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 21: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID bp.power (0xf)

Entity ID 13.1 (Back Panel Board)

Sensor Type (Discrete) Power Supply

States Asserted Digital State

[State Asserted]

Sensor ID bp.locate (0x10)

Entity ID 13.2 (Back Panel Board)

Sensor Type (Discrete) Button

States Asserted Digital State

[State Asserted]

Sensor ID bp.locate.btn (0x11)

Entity ID 13.2 (Back Panel Board)

Sensor Type (Discrete) Button

States Asserted Digital State

[State Deasserted]

Assertions Enabled Digital State

[State Asserted]

Sensor ID bp.alert (0x12)

Entity ID 13.3 (Back Panel Board)

Sensor Type (Discrete) Platform Alert

States Asserted Digital State

[State Deasserted]

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 17

Page 22: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID fp.prsnt (0x13)

Entity ID 12.0 (Front Panel Board)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

Sensor ID fp.t_amb (0x14)

Entity ID 12.0 (Front Panel Board)

Sensor Type (Analog) Temperature

Sensor Reading 23 (+/- 0) degrees C

Status OK

Upper nonrecoverable 43.000

Upper critical 35.000

Upper noncritical 30.000

Positive Hysteresis Unspecified

Negative Hysteresis Unspecified

Minimum sensor range -127.000

Maximum sensor range 127.000

Event Message Control Per-threshold

Readable Thresholds unc ucr unr

Settable Thresholds unc ucr unr

Threshold Read Mask unc ucr unr

Assertions Enabled ucr+ unr+

Deassertions Enabled ucr+ unr+

TABLE 4 Sensor Details (Continued)

Sensor Data

18 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 23: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID fp.usbfail (0x15)

Entity ID 12.0 (Front Panel Board)

Sensor Type (Discrete) Slot / Connector

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID fp.power (0x16)

Entity ID 12.1 (Front Panel Board)

Sensor Type (Discrete) Power Supply

States Asserted Digital State

[State Asserted]

Sensor ID fp.locate (0x17)

Entity ID 12.2 (Front Panel Board)

Sensor Type (Discrete) Button

States Asserted Digital State

[State Deasserted]

Sensor ID fp.locate.btn (0x18)

Entity ID 12.2 (Front Panel Board)

Sensor Type (Discrete) Button

States Asserted Digital State

[State Deasserted]

Assertions Enabled Digital State

[State Asserted]

Sensor ID fp.alert (0x19)

Entity ID 12.3 (Front Panel Board)

Sensor Type (Discrete) Platform Alert

States Asserted Digital State

[State Deasserted]

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 19

Page 24: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID fp.ledbd.prsnt (0x1a)

Entity ID 12.0 (Front Panel Board)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

Sensor ID pdb.t_amb (0x1b)

Type Temperature

Class Threshold Sensor

Value 15.000 degree C

Upper_nonrecov_threshold 80.000 degree C

Upper_critical_threshold 75.000 degree C

Upper_noncritical_threshold 70.000 degree C

Lower_noncritical_threshold N/A

Lower_critical_threshold N/A

Lower_nonrecov_threshold N/A

Sensor ID ps0.prsnt (0x1c)

Entity ID 10.0 (Power Supply)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

Sensor ID ps0.pwrok (0x1d)

TABLE 4 Sensor Details (Continued)

Sensor Data

20 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 25: Integrated Lights Out Manager (ILOM) Supplement for Sun

Entity ID 10.0 (Power Supply)

Sensor Type (Discrete) Power Supply

States Asserted Digital State

[State Asserted]

Assertions Enabled Digital State

[State Deasserted]

[State Asserted]

Sensor ID ps0.vinok (0x1e)

Entity ID 10.0 (Power Supply)

Sensor Type (Discrete) Power Supply

States Asserted Digital State

[State Asserted]

Assertions Enabled Digital State

[State Deasserted]

[State Asserted]

Sensor ID ps1.prsnt (0x1f)

Entity ID 10.1 (Power Supply)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Absent]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

Sensor ID ps1.pwrok (0x20)

Entity ID 10.1 (Power Supply)

Sensor Type (Discrete) Power Supply

Assertions Enabled Digital State

[State Deasserted]

[State Asserted]

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 21

Page 26: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID ps1.vinok (0x21)

Entity ID 10.1 (Power Supply)

Sensor Type (Discrete) Power Supply

Assertions Enabled Digital State

[State Deasserted]

[State Asserted]

Sensor ID io.t_amb (0x22)

Upper nonrecoverable 80.000

Upper critical 75.000

Upper noncritical 70.000

Sensor ID io.id0.prsnt (0x23)

Entity ID 15.0 (Drive Backplane)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Absent]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

Sensor ID io.id1.prsnt (0x24)

Entity ID 15.0 (Drive Backplane)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

TABLE 4 Sensor Details (Continued)

Sensor Data

22 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 27: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID io.f0.prsnt (0x25)

Entity ID 15.0 (Drive Backplane)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

Sensor ID io.f0.speed (0x26)

Upper nonrecoverable 8000.000

Lower nonrecoverable 3000.000

Sensor ID io.hdd0.fail (0x28)

Entity ID 4.0 (Disk or Disk Bay)

Sensor Type (Discrete) Drive Slot / Bay

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Deasserted]

[Predictive Failure Asserted]

Sensor ID io.hdd1.fail (0x29)

Entity ID 4.1 (Disk or Disk Bay)

Sensor Type (Discrete) Drive Slot / Bay

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Deasserted]

[Predictive Failure Asserted]

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 23

Page 28: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID io.hdd2.fail (0x2a)

Entity ID 4.2 (Disk or Disk Bay)

Sensor Type (Discrete) Drive Slot / Bay

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Deasserted]

[Predictive Failure Asserted]

Sensor ID io.hdd3.fail (0x2b)

Entity ID 4.3 (Disk or Disk Bay)

Sensor Type (Discrete) Drive Slot / Bay

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Deasserted]

[Predictive Failure Asserted]

Sensor ID p0.t_core (0x2c)

Type Temperature

Class Threshold Sensor

Value Not Readable

Upper_nonrecov_threshold 75.000 degree C

Upper_critical_threshold 67.000 degree C

Upper_noncritical_threshold 62.000 degree C

Lower_noncritical_threshold N/A

Lower_critical_threshold N/A

Lower_nonrecov_threshold N/A

Sensor ID p0.v_vdd (0x2d)

Type Voltage

Class Threshold Sensor

Value Not Readable

TABLE 4 Sensor Details (Continued)

Sensor Data

24 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 29: Integrated Lights Out Manager (ILOM) Supplement for Sun

Nonrecov_threshold 0.792 Volts

Upper_nonrecov_threshold 1.800 Volts

Upper_critical_threshold 1.692 Volts

Upper_noncritical_threshold 1.596 Volts

Lower_noncritical_threshold 0.996 Volts

Lower_critical_threshold 0.900 Volts

Lower_nonrecov_threshold 0.792 Volts

Sensor ID p0.v_vddio (0x2e) and p1.v_vddio (0x37)/SYS/MB/P0/V_VDDIO

Type Voltage

Class Threshold Sensor

Value Not Readable

Upper_nonrecov_threshold 2.196 Volts

Upper_critical_threshold 2.100 Volts

Upper_noncritical_threshold 1.992 Volts

Lower_noncritical_threshold 1.596 Volts

Lower_critical_threshold 1.500 Volts

Lower_nonrecov_threshold 1.392 Volts

Sensor ID p0.v_vtt (0x2f)

Sensor Type (Analog) Voltage

Class Threshold Sensor

Value Not Readable

Upper nonrecoverable threshold 1.200 Volts

Upper critical threshold 1.092 Volts

Upper noncritical threshold 0.996 Volts

Lower noncritical threshold 0.792 Volts

Lower critical threshold 0.696 Volts

Lower nonrecoverable threshold 0.600 Volts

Sensor ID p0.fail (0x30)

Entity ID 3.0 (Processor)

Sensor Type (Discrete) Processor

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 25

Page 30: Integrated Lights Out Manager (ILOM) Supplement for Sun

States Asserted Digital State

[Predictive Failure Asserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID p0.d0.fail (0x31)

Entity ID 32.0 (Memory Device)

Sensor Type (Discrete) Memory

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID p0.d1.fail (0x32)

Entity ID 32.1 (Memory Device)

Sensor Type (Discrete) Memory

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID p0.d2.fail (0x33)

Entity ID 32.2 (Memory Device)

Sensor Type (Discrete) Memory

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID p0.d3.fail (0x34)

Entity ID 32.3 (Memory Device)

Sensor Type (Discrete) Memory

States Asserted Digital State

[Predictive Failure Deasserted]

TABLE 4 Sensor Details (Continued)

Sensor Data

26 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 31: Integrated Lights Out Manager (ILOM) Supplement for Sun

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID p1.t_core (0x35)

Entity ID 3.1 (Processor)

Sensor Type (Analog) Temperature

Sensor Reading 44 (+/- 0) degrees C

Status OK

Upper nonrecoverable 75.000

Upper critical 65.000

Upper noncritical 60.000

Positive Hysteresis 2.000

Negative Hysteresis 2.000

Minimum sensor range Unspecified

Maximum sensor range Unspecified

Event Message Control Per-threshold

Readable Thresholds unc ucr unr

Settable Thresholds unc ucr unr

Threshold Read Mask unc ucr unr

Assertions Enabled ucr+ unr+

Deassertions Enabled ucr+ unr+

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 27

Page 32: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID p1.v_vdd (0x36)

Entity ID 3.1 (Processor)

Sensor Type (Analog) Voltage

Sensor Reading 1.452 (+/- 0) Volts

Status OK

Upper nonrecoverable 1.8

Upper critical 1.7

Upper noncritical 1.6

Lower nonrecoverable 0.8

Lower critical 0.9

Lower noncritical 1.0

Positive Hysteresis 0.096

Negative Hysteresis 0.096

Minimum sensor range Unspecified

Maximum sensor range Unspecified

Event Message Control Per-threshold

Readable Thresholds lnr lcr lnc unc ucr unr

Settable Thresholds lnr lcr lnc unc ucr unr

Threshold Read Mask lnr lcr lnc unc ucr unr

Assertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Deassertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

TABLE 4 Sensor Details (Continued)

Sensor Data

28 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 33: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID p1.v_vtt (0x38)

Type Voltage

Class Threshold sensor

Value Not readable

Upper non-reoverable threshold 1.200 volts

Upper critical threshold 1.092 volts

Upper noncritical threshold 0.996 volts

Lower noncritical threshold 0.792 volts

Lower critical threshold 0.696 volts

Lower nonrecoverable threshold 0.600 volts

Minimum sensor range Unspecified

Maximum sensor range Unspecified

Event Message Control Per-threshold

Readable Thresholds lnr lcr lnc unc ucr unr

Settable Thresholds lnr lcr lnc unc ucr unr

Threshold Read Mask lnr lcr lnc unc ucr unr

Assertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Deassertions Enabled lnc- lcr- lnr- unc+ ucr+ unr+

Sensor ID p1.fail (0x39)

Entity ID 3.1 (Processor)

Sensor Type (Discrete) Processor

States Asserted Digital State

[Predictive Failure Asserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 29

Page 34: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID p1.d0.fail (0x3a)

Entity ID 32.4 (Memory Device)

Sensor Type (Discrete) Memory

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID p1.d1.fail (0x3b)

Entity ID 32.5 (Memory Device)

Sensor Type (Discrete) Memory

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID p1.d2.fail (0x3c)

Entity ID 32.6 (Memory Device)

Sensor Type (Discrete) Memory

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID p1.d3.fail (0x3d)

Entity ID 32.7 (Memory Device)

Sensor Type (Discrete) Memory

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

TABLE 4 Sensor Details (Continued)

Sensor Data

30 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 35: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID ft0.fm0.fail (0x3e)

Entity ID 29.0 (Fan Device)

Sensor Type (Discrete) Fan

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID ft0.fm1.fail (0x3f)

Entity ID 29.1 (Fan Device)

Sensor Type (Discrete) Fan

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID ft0.fm2.fail (0x40)

Entity ID 29.2 (Fan Device)

Sensor Type (Discrete) Fan

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID ft1.fm0.fail (0x41)

Entity ID 29.3 (Fan Device)

Sensor Type (Discrete) Fan

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 31

Page 36: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID ft1.fm1.fail (0x42)

Entity ID 29.4 (Fan Device)

Sensor Type (Discrete) Fan

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID ft1.fm2.fail (0x43)

Entity ID 29.5 (Fan Device)

Sensor Type (Discrete) Fan

States Asserted Digital State

[Predictive Failure Deasserted]

Assertions Enabled Digital State

[Predictive Failure Asserted]

Sensor ID ft0.fm0.prsnt (0x44)

Entity ID 29.0 (Fan Device)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

Sensor ID ft0.fm1.prsnt (0x45)

Entity ID 29.1 (Fan Device)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

TABLE 4 Sensor Details (Continued)

Sensor Data

32 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010

Page 37: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID ft0.fm2.prsnt (0x46)

Entity ID 29.2 (Fan Device)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

Sensor ID ft1.fm0.prsnt (0x47)

Entity ID 29.3 (Fan Device)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

Sensor ID ft1.fm1.prsnt (0x48)

Entity ID 29.4 (Fan Device)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

TABLE 4 Sensor Details (Continued)

Sensor Data

Introduction 33

Page 38: Integrated Lights Out Manager (ILOM) Supplement for Sun

Sensor ID ft1.fm2.prsnt (0x49)

Entity ID 29.5 (Fan Device)

Sensor Type (Discrete) Entity Presence

States Asserted Availability State

[Device Present]

Assertions Enabled Availability State

[Device Absent]

[Device Present]

Sensor ID ft0.fm0.f0.speed (0x4a),ft0.fm1.f0.speed (0x4b),ft0.fm2.f0.speed (0x4c),ft1.fm0.f0.speed (0x4d),ft1.fm1.f0.speed (0x4e),ft1.fm2.f0.speed (0x4f)

Type Fan

Class Threshold Sensor

Value Not Readable

Upper_nonrecov_threshold 22000.000 RPM

Upper_critical_threshold N/A

Upper_noncritical_threshold N/A

Lower_noncritical_threshold N/A

Lower_critical_threshold N/A

Lower_nonrecov_threshold 3000.000 RPM

TABLE 4 Sensor Details (Continued)

Sensor Data

34 ILOM Supplement for Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers • February 2010