INSTRUCTIONS FOR CONNECTING
YOUR PC TO A BLAST CHILLER USING HACCP SOFTWARE.
PURPOSE OF HACCP SOFTWARE. HACCP software imports all IRINOX blast chiller cycles into a computer. It automatically records:
- air temperature - product temperature (when working in AUTOMATIC mode) - length of the blast chilling or shock freezing phase - length of the holding phase - type of cycle (LOGIK, SOFT, HARD, HARD PLUS and FREEZING) - machine model with photograph - cycle start and stop date and time - any alarms or other events
As will be explained below, it can also provide more detailed data about each cycle, for example product name, weight and thickness, for better monitoring of the manufacturing process.
1
1) CONNECTING A BLAST CHILLER TO A PC. There are two ways of connecting a blast chiller to a PC: by direct connection through an RS232 serial port, or through an RS485 mod-bus connection which allows a PC to be connected to up to 32 blast chillers. --------------------------------------------------------------------------------------------------------------------------------------------------------------
CO
---------------
C
--------------- The serial cfrom whichbe requestemanufactur
DIRECT NNECTION
-----------------------------------------------------------------------------------------------------------------------------------------------
MOD-BUS ONNECTION------------------------------------------------------------------------------------------------------------------------------------------------
onnection for LC models is on the front of the machine and is a 9 pin (PC type) connector. The machine data is to be downloaded should be connected to this. The connector on HC models is optional and should d when placing an order or may be fitted later by replacing the panel and adding a cable supplied by the er.
2
2) DIRECT CONNECTION. With this type of connection there is a 5 metre distance limit between the PC and the blast chiller. To set up a connection between the PC and the LC51, LC101/35 and all HC models, the following conditions apply:
1) Dip switch no. 3 located on the electronic card must be ON (the default setting is OFF). 2) During communication the blast chiller must be in standby mode, i.e. it must not be running a cycle 3) Start up the software on the PC, connect the PC to the blast chiller with the 9 pin serial cable and download
data 4) Once the download is complete the blast chiller can be used.
DIP SWITCH LOCATION
To set up a connection between the PC and the models from LC101/50 to LC602/750, the following conditions apply:
1) Dip switch no. 4 located on the back of the front card (control panel) must be ON (the default setting is OFF). 2) During communication the blast chiller must be in standby mode, i.e. it must not be running a cycle. 3) To enable communication click the PRINT CYCLE button. The word TRASMISSIONE (TRANSMISSION) will
then appear on the display. 4) Start up the software on the PC, connect the PC to the blast chiller with the serial cable and download data. 5) At the end of transmission click the PRINT CYCLE button again to exit transmission mode.
DIP SWITCH LOCATION
3
STARTING UP SOFTWARE IN SERIAL MODE
SELECT SERIAL DIRECT COMMUNICATION
SELECT PC SERIAL PORT
4
3) MOD-BUS CONNECTION With this type of connection blast chiller/s can be up to 1 kilometre away and up to 32 blast chillers can be connected to a single PC. To set up the connection use a shielded 2 x 0,5 mm cable. The mod-bus card is fitted to the machine’s electrical system. LC – HC Series
Address setting for PC connection to multiple machines
5
Use the dip switches KD3 and KD2 to set the MOD BUS address, as shown in the following table.
WARNING!! Do not move KD4 and KD5
To verify connections follow the sequence of lighting LEDs: - DL1 is ON - DL2 lights ON after few seconds - DL4 makes a flash after few seconds - DL1 starts to blink when receives first correct input from the PC
Connect the cable shielding into the ground clamp “GND”
shielded cable
shielded cable
Communication with another blast
chiller
Connector for CPU board cod. 3600160
“Converter connection kit” Irinox code: 8L0001020 • Converter RS232 to RS 485 • + Connection cable PC – Converter • + Transformer for converter
LC – HC Series
Address setting for PC connection to multiple machines MOD BUS card Irinox code 3600180 Set dip switches on card as per the table. Each machine must have its own individual mod-bus address which must be different for each blast chiller. Progressive number
of the machines connected to the PC
Machine address shown on the
HACCP software KD3 KD2
dip-1 dip-2 dip-3 dip-4 dip-1 dip-2 dip-3 dip-4 1 32 ON ON ON ON ON ON ON ON 2 33 ON ON ON ON ON ON ON OFF 3 34 ON ON ON ON ON ON OFF ON 4 35 ON ON ON ON ON ON OFF OFF 5 36 ON ON ON ON ON OFF ON ON 6 37 ON ON ON ON ON OFF ON OFF 7 38 ON ON ON ON ON OFF OFF ON 8 39 ON ON ON ON ON OFF OFF OFF 9 40 ON ON ON ON OFF ON ON ON
10 41 ON ON ON ON OFF ON ON OFF 11 42 ON ON ON ON OFF ON OFF ON 12 43 ON ON ON ON OFF ON OFF OFF 13 44 ON ON ON ON OFF OFF ON ON 14 45 ON ON ON ON OFF OFF ON OFF 15 46 ON ON ON ON OFF OFF OFF ON 16 47 ON ON ON ON OFF OFF OFF OFF 17 48 ON ON ON OFF ON ON ON ON 18 49 ON ON ON OFF ON ON ON OFF 19 50 ON ON ON OFF ON ON OFF ON 20 51 ON ON ON OFF ON ON OFF OFF 21 52 ON ON ON OFF ON OFF ON ON 22 53 ON ON ON OFF ON OFF ON OFF 23 54 ON ON ON OFF ON OFF OFF ON 24 55 ON ON ON OFF ON OFF OFF OFF 25 56 ON ON ON OFF OFF ON ON ON 26 57 ON ON ON OFF OFF ON ON OFF 27 58 ON ON ON OFF OFF ON OFF ON 28 59 ON ON ON OFF OFF ON OFF OFF 29 60 ON ON ON OFF OFF OFF ON ON 30 61 ON ON ON OFF OFF OFF ON OFF 31 62 ON ON ON OFF OFF OFF OFF ON 32 63 ON ON ON OFF OFF OFF OFF OFF
NB: No other combination is acceptable: alarm OFF LINE means connection has failed.
32 33 34 35 63 Address
CPU Mod Bus
CPU Mod Bus
CPU Mod Bus
CPU Mod Bus
CPU Mod Bus
Blast chiller No. 1
Blast chiller No. 2
Blast chiller No. 3
Blast chiller No. 4
Blast chiller No. 32
Con
verte
r R
S 23
2 -
RS4
85
Max : 1 km
6
STARTING UP SOFTWARE IN MOD-BUS MODE Having set up the connection with the PC, start up HACCP software then scan the MOD-BUS addresses to enable automatic recognition of the blast chillers connected. (This should only be done the first time the software is started up).
LIST OF CONNECTED MACHINES
When scanning is complete, click the CLOSE button and the general data from the connected blast chillers will be stored.
7
4) DOWNLOADING DATA.
Select language
Select communication mode
Click Download to download data
8
Click COPY to copy a cycle, then see next window
The cycle has now
Click COPY ALL to copy all cycles and delete them from blast chiller memory.
INSERT REQUESTED INFORMATION IN EMPTY BOXES (MUST COMPLETE AT LEAST THE PRODUCT DESCRIPTION BOX)
DONE BUTTON
ABORT BUTTON
been stored in PC memory.
9
All stored cycles are now in PC memory. Reports and graphics for each cycle can now be viewed and printed.
Click the GRAPH button to view more information about the cycle.
10
To print, click the PRINT button, then select options.
PRINT GRAPH AND TEXT PRINT TEXT ONLY
PRINT GRAPH ONLY
CLICK TO SELECT COLOUR OR BLACK AND WHITE PRINTING
11
5) BUTTONS
PRINT A CYCLE
VIEW CYCLE GRAPH
DA
TE A
ND
TIM
E
CY
CLE
TY
PE
PRO
DU
CT
TYPE
PRO
DU
CT
THI C
KN
ESS
TOTA
L PR
OD
UC
T W
EIG
HT
PRO
DU
CT
NA
ME LIST OF
CONNECTED MACHINES
EXIT PROGRAMME
SOFTWARE VERSION &WEB SITE
CLICK TO SET LANGUAGE, COM., & COMMUNICATIONTYPE
CLICK TO TRANSFER CYCLFROM BLAST CHI
ES
LLER TO PC
CLICK TO GO TO SAVED CYCLES WINDOW
EDIT CYCLE DETAILS DELETE A CYCLE
MA
CH
INE
CO
DE;
OPE
RA
TOR
N
AM
E ; L
OT
CO
DE
12
SEARCH CYCLES BY PRODUCT NAME
SEARCH CYCLES BY DATE RANGE
SEARCH CYCLES BY LOT CODE
SEARCH CYCLES BY DISH TYPE
VIEW ALL CYCLES
SELECT PC SERIAL PORT
MACHINE CONNECTION TYPE (SEE INTRODUCTION)
ORY
COPY A CYCLE FROM BLAST CHILLER MEMORY TO PC MEM
COPY ALL CYCLES FROM BLAST CHILLER MEMORY TO PC MEMORY, AND AUTOMATICALLY ERASE BLAST CHILLER MEMORY
VIEW CYCLE GRAPH
BUSINESS NAME
ENTER PASSWORD TO DELETE CYCLES SELECT LANGUAGE
SCAN MOD-BUS ADDRESSES TO FIND CONNECTED MACHINES (DO THIS ONLY THE FIRST TIME THE PROGRAMME IS LAUNCHED, OR IF A MACHINE IS ADDED). IF THERE ARE PROBLEMS RECOGNISING ONE OR MORE BLAST CHILLERS CHECK THAT CONNECTIONS ARE SOUND, THAT THE PC SERIAL PORT IS FREE. THAT THE RS232-RS485 CONVERTER HAS POWER AND THAT BLAST CHILLERS HAVE POWER AND ARE ON STANDBY.
13
DELETE A CYCLE FROM PC MEMORY
DELETE ALL MACHINE MEMORY
CONNECT TO BLAST CHILLER TO DOWNLOAD CYCLE DATA
14
6) TROUBLESHOOTING
PROBLEM LIKELY CAUSE RECOMMENDED ACTION
Scanning of mod-bus addresses does not recognise one or more blast chillers (see. p.7)
The blast chiller’s card is set to OFF Check that the blast chiller is turned ON
Mod-bus card dip switch settings are incorrect
Check dip switch settings
The RS232-RS48 converter is not switched on
Check power supply
The RS232-RS485 converter is not set correctly.
(the converter supplied by Irinox does not require setting)
See converter instructions and configure correctly
Loose converter or mod bus connections (see p. 5)
Check connections
PC serial port not enabled Check that PC serial port is properly selected and is free
Communication not working with direct serial port connection.
Dip switch no.3 of card is not set to ON (see p. 3).
ONLY FOR MODELS “HC” AND “LC51.25” AND “LC101.35”
Check dip switch position
Dip switch n. 4 of front card is not set to ON (see p. 3).
ONLY FOR MODELS “LC141.60” TO “LC602.750”
Check dip switch position
Transmission has not been enabled by clicking the “PRINT CYCLE” button on the machine control panel.
ONLY FOR MODELS “LC141.60” TO “LC602.750”
Click the “PRINT CYCLE” button and try connecting again
PC serial port not enabled Check that PC serial port is properly selected and is free