9 Mounting the stand-alone BTS on thewall
9.1 Mounting the plinth on a wall
Purpose
A plinth is required for mounting the modules on a wall.
Before you start
Check that the plinth adapter mechanics are installed as instructed in the
Fixing adapter mechanics to plinth section.
If installing additional plinths one upon the other, the distance between theupper mounting screw holes in first and second plinth must be 550 mm
(21.7 in.) minimum.
Summary
DN70305645Issue 3-0 en21/01/2008
# Nokia Siemens Networks 37 (97)
Mounting the stand-alone BTS on the wall
-
7/29/2019 Install Flexi Wall
2/12
Figure 14. Mounting the plinth on a wall
2
5
6 tighten the screws
3
4
1
DN7037067
185 mm
482,5
mm
38 (97) # Nokia Siemens Networks DN70305645Issue 3-0 en
21/01/2008
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
-
7/29/2019 Install Flexi Wall
3/12
Steps
1. Mark the mounting screw locations on the wall and drill the
holes for the screws.
2. Fix the upper mounting screws to the wall, lift the plinth on thewall and fit it to the mounting screws.
Check that the plinth is level.
3. Tighten the upper mounting screws.
4. Insert the lower mounting screws.
5. Tighten the lower mounting screws.
6. Make sure that the plinth is not twisted.
When the plinth is in a correct position, tighten the three screws inthe lower bracket of the adapter mechanics.
7. In case you are installing more than one plinth, repeat steps 1-6
for each plinth.
Note that the required space between the plinths is 100 mm.
DN70305645Issue 3-0 en21/01/2008
# Nokia Siemens Networks 39 (97)
Mounting the stand-alone BTS on the wall
-
7/29/2019 Install Flexi Wall
4/12
Figure 15. Mounting a second plinth on the wall
Further information
Next, ground the plinth to the site main ground. For more information, see
Grounding principle of the stand-alone BTS .
DN7047057
185 mm (7.3 in)
600mm
(23.6
in)
482,5mm
(19.0
in)
The distance between the twoplinths must be 100 mm (3.9 in) 185 mm (7.3 in)
40 (97) # Nokia Siemens Networks DN70305645Issue 3-0 en
21/01/2008
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
-
7/29/2019 Install Flexi Wall
5/12
9.2 Mounting modules on a wall
Purpose
The stand-alone BTS can be installed on a wall. The maximum number of
modules per plinth is two.
Note
To meet the earthquake requirement Telcordia GR-63-CORE and the
vibrational requirements for Earthquake Zone 4, the four module fixing
screws between the module core and the module casing must betightened to 5 Nm.
Before you start
Check that:
. the plinth is installed as instructed. See Mounting the plinth on a wall
for plinth installation instructions.
. the plinth is grounded.
. there is one plinth per two modules.
If you are going to install Flexi Power Module (FPMA), it should be
installed on the same plinth as the System Module. For more informationon FPMA installation, see Installing Flexi Power Module (FPMA).
The recommended module installation order is illustrated in the followingfigure.
DN70305645Issue 3-0 en21/01/2008
# Nokia Siemens Networks 41 (97)
Mounting the stand-alone BTS on the wall
-
7/29/2019 Install Flexi Wall
6/12
Figure 16. Recommended module installation order
RF Module
RF Module
RF Module
Plinth
Wall
DN7055446
System Module
Power Module(optional)
42 (97) # Nokia Siemens Networks DN70305645Issue 3-0 en
21/01/2008
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
-
7/29/2019 Install Flexi Wall
7/12
Summary
Caution
Excess torsion damages the casings. In wall and pole installation, do
not install more than two modules per plinth.
Caution
Incorrect installation may lead to damage to the modules. The modules
must be installed with the front panels facing left or right. Do not installthe modules with the front panels facing up or down.
DN70360702
DN70305645Issue 3-0 en21/01/2008
# Nokia Siemens Networks 43 (97)
Mounting the stand-alone BTS on the wall
-
7/29/2019 Install Flexi Wall
8/12
Figure 17. Mounting the modules on the wall
5
1
3
DN7037079
Line up thelocating marks
Line up the
locating marks
6
2 4
8
7
9
44 (97) # Nokia Siemens Networks DN70305645Issue 3-0 en
21/01/2008
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
-
7/29/2019 Install Flexi Wall
9/12
Steps
1. Align the holes on the first module's bottom with the fixing
studs on the plinth.
Tip
Line up the locating marks on the side of the module to help aligning the
holes with fixing studs.
2. Push the module back until it stops.
3. Attach the module casing to the plinth with two screws.
Secure with thread locking compound.
4. Connect the module grounding cable between the module front
panel and the plinth.
See Grounding principle of the stand-alone BTS for moreinformation.
5. Align the holes on the second module's bottom with the fixingstuds on the first module.
6. Push the module back until it stops.
7. Attach the module casings to each other with two screws.
Secure with thread locking compound.
8. Connect the module grounding cable between the module front
panel and the plinth.
9. Attach the fixing plates across the module casings on both
sides of the modules and fix with six screws and spring
washers.
Secure with thread locking compound.
DN70305645Issue 3-0 en21/01/2008
# Nokia Siemens Networks 45 (97)
Mounting the stand-alone BTS on the wall
-
7/29/2019 Install Flexi Wall
10/12
Figure 18. Installing fixing plates for the casing
10. Repeat the steps above to install the remaining modules to a
separate plinth or plinths.
One plinth can have two modules installed. A configuration of one
System Module and three RF Modules therefore requires twoplinths.
DN70144135
46 (97) # Nokia Siemens Networks DN70305645Issue 3-0 en
21/01/2008
Installing Flexi WCDMA BTS Modules for Stack, Wall, and Pole
Configurations
-
7/29/2019 Install Flexi Wall
11/12
Expected outcome
The following figure illustrates one example of the basic configuration of
one System Module and three RF Modules installed on the wall. The
installation in the figure is a right-hand installation, but the BTS can also be
installed as a left-hand installation.
Tip
Right-hand installation is recommended.
DN70305645Issue 3-0 en21/01/2008
# Nokia Siemens Networks 47 (97)
Mounting the stand-alone BTS on the wall
-
7/29/2019 Install Flexi Wall
12/12