inspector: mark baxley, brick and mortar home inspections ... · page 34 item: 6 deck there is...

97
1234 Sample Drive Inspection prepared for: John Doe Date of Inspection: 7/31/2018 Time: 12:00 PM Age of Home: 1983 (35 years) Size: 2,251 SF Weather: Sunny; 72 Degrees Email: [email protected] Inspector: Mark Baxley

Upload: others

Post on 08-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Inspector: Mark Baxley, Brick and Mortar Home Inspections, Inc.

Cover Page

1234 Sample DriveInspection prepared for: John Doe

Date of Inspection: 7/31/2018 Time: 12:00 PM Age of Home: 1983 (35 years) Size: 2,251 SF

Weather: Sunny; 72 Degrees

Email: [email protected]: Mark Baxley

Page 2: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 1 of 96

Report Summary

Report SummaryThe summary below consists of potentially significant findings. These findings can be a safetyhazard, a deficiency requiring a major expense to correct or items I would like to draw extra attentionto. The summary is not a complete listing of all the findings in the report, and reflects the opinion ofthe inspector. Please review all pages of the report as the summary alone does not explain all of theissues. All repairs should be done by a licensed & bonded tradesman or qualified professional. Irecommend obtaining a copy of all receipts, warranties and permits for the work done.ROOFPage 26 Item: 1 ROOF

CONDITIONThe roof exhibits wear and granule loss consistent with age.There are no signs of hail damage. There are also no signs ofproduct or installation defects. However, there are severaldamaged shingles visible on the roof. Recommend licensedroofer or qualified contractor examine and repair as needed.

Damaged shingles Damaged shingles

Damaged shingles Damaged shingles

Page 3: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 2 of 96

Page 27 Item: 3 PLUMBINGVENTS

The pipe jacks around the plumbing vents are damagedand/or deteriorated. The resulting gaps around the base ofthe vent pipes could be susceptible to moisture intrusion.Recommend licensed roofer repair or replace to prevent leaksand possible damage.

One of the plumbing vents on an east facing slope does notextend at least 6" above the roof as required. Code requiresplumbing vents to terminate at least 6" above the roof orabove the snow depth that usually collects on the roof,whichever is higher. This is to ensure the plumbing does notbecome blocked with snow and ice. Blocked vents couldcause sewer gases to enter the home. Recommend licensedplumber or qualified contractor examine and repair as needed.

Plumbing vent too low Pipe jack around plumbing vent damaged

Pipe jack around plumbing vent damaged Pipe jack around plumbing vent damaged

Page 28 Item: 6 CHANNELS The roof to wall channel on the west facing slope is notadequate. This could cause water to dam behind the shinglesand/or flashing resulting in roof leaks. Recommend licensedroofer or qualified contractor examine and repair as needed.

Page 4: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 3 of 96

Roof to wall channel inadequate

Page 29 Item: 10 GUTTERS The gutters are dirty. Standing water could lead to rustingand leaking over an extended period. Recommend cleaningto ensure adequate water flow to the downspouts.

The downspouts are not equipped with extensions. Waterdeposited next to the home can exert hydrostatic pressure onthe foundation walls and could result in a wet basement orcrawlspace. Recommend installing extensions so that waterrunoff is carried at least 4' away from the structure.

Page 5: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 4 of 96

Downspout extension missing Downspout extension missing

Downspout extension missing Downspout extension missing

Dirty gutter Dirty gutter

CHIMNEY

Page 6: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 5 of 96

Page 31 Item: 1 CHIMNEYCONDITION

• The concrete chimney cap is cracked and damaged.Recommend qualified contractor repair or replace as needed.

Chimney cap cracked and damaged

EXTERIOR CLADDING, WINDOWS, AND DOORSPage 32 Item: 1 EXTERIOR

CLADDINGThere is moisture damage visible on one of the east facing lapboards. Recommend qualified contractor repair, prep, andpaint as needed.

Damaged siding

Page 32 Item: 3 EXTERIOR DOORCONDITION

The patio slider is not equipped with a screen. Recommendinstalling or replacing as needed.

GROUNDSPage 33 Item: 1 DRIVEWAY There is flaking and deteriorating concrete (known as

"spalling") visible in the driveway. Spalling concrete can onlybe repaired if a bonding agent is used to ensure the newconcrete bonds with the old. Recommend qualified contractorexamine and repair or replace as needed.

Page 7: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 6 of 96

Spalling concrete Spalling concrete

Page 34 Item: 6 DECK There is moisture damage visible on the deck joists.Recommend qualified contractor examine and repair asneeded.

The guardrails around the perimeter of the deck are loose.Potential safety hazard. Recommend qualified contractorexamine and repair as needed.

There is significant moisture damage visible on the stairstringers. Recommend qualified contractor examine andrepair as needed.

The TREX decking is peeling and deteriorating. Recommendqualified contractor examine and repair as/if needed.

Page 8: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 7 of 96

Wood rot on deck joist Wood rot on deck joist

Wood rot on deck joist Wood rot on deck joist

Wood rot on stair stringer Wood rot on stair stringer

Page 9: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 8 of 96

Wood rot on stair stringer Wood rot on stair stringer

Page 35 Item: 7 FENCE There are numerous broken, damaged, and/or loose pickets.Recommend replacing or securing as needed.

There are several damaged and/or detached fence rails.Recommend repairing and/or securing as needed.

Some of the posts do not appear to be set in concrete. Postsset in the ground are susceptible to moisture damage. At thetime of the inspection, several broken posts were observed.Recommend qualified contractor examine and repair asneeded.

Detached fence rail Broken fence post

Page 36 Item: 8 GRADING There is negative grading on the south and east sides of thehome. Moisture pooling next to a structure can exerthydrostatic pressure on the foundation walls and could resultin a wet basement or crawlspace. Recommend qualifiedcontractor evaluate and mitigate as needed. This will mostlikely entail adding backfill and/or regrading to create theproper pitch so that moisture is diverted away from thestructure. Proper pitch is generally considered 1" drop perfoot for 5' - 6'.

Page 10: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 9 of 96

Negative grading east side of home Negative grading on south side of home

Page 37 Item: 11 WINDOW WELLS The window well on the south side of the home does notappear to be deep enough. As a result, the basement couldbe susceptible to moisture intrusion during heavy rains orsnows. Generally, there should be at least 6” of rock in thebase of the window well and at least 3” between the top of therock and the bottom of the window. Recommend deepeningthe window well or installing a plastic cover to minimize theamount of moisture entering the window well.

Page 37 Item: 12 HOSE BIBS The hose bib on the west side of the home is not equippedwith an anti-siphon valve. This type of valve preventsirrigation and/or dirty water from entering the home’s drinkingsupply. Although not required when this home was built,recommend licensed plumber or qualified contractor install.

The knob on the south facing hose bib is damaged or missing.This makes opening and closing the valve very difficult.Recommend repairing as needed.

Knob on south facing hose bib is missing

EXTERIOR ELECTRICAL

Page 11: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 10 of 96

Page 39 Item: 1 EXTERIORELECTRICAL

• The duplex outlet above the patio on the east side of thehome is inoperable. At the time of the inspection, there wereno breakers tripped in the electrical panel. In addition, therewere no GFCI outlets tripped in the home or garage.Recommend licensed electrician repair as needed.• The outlets on the west side of the home are not GFCIprotected. Potential safety hazard. Recommend licensedelectrician repair.

DETACHED GARAGEPage 42 Item: 14 FRAMING AND

INSULATIONThere is insulation installed between the wall studs in thegarage. The insulation is installed with the flammable paperfacing exposed. Potential safety hazard. There is a warninglabel on the insulation that indicates the facing is flammableand should be covered with gypsum board or other approvedbuilding material. Recommend covering to ensure the garageis safe.

Flammable paper facing exposed

ATTACHED GARAGEPage 43 Item: 5 ELECTRICAL The 4-plex outlet on the south wall is not GFCI protected as

required. Potential safety hazard. When this home was built,electrical codes required all garage outlets to be GFCIprotected except if (1) the receptacles were not readilyaccessible (e.g. a ceiling outlet powering an overhead dooropener); or (2) the outlets were single receptacles designatedfor equipment not easily moved (e.g. freezer); or (3) theoutlets were duplex receptacles that were designated for twofixed appliances. Since this outlet does not meet thesecriteria, recommend licensed electrician repair.

There is exposed Romex wiring on the south wall. Potentialsafety hazard. Recommend licensed electrician repair. Thiswill most likely entail enclosing the wiring in conduit.

Definition
A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system.
Page 12: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 11 of 96

Exposed Romex wiring

Page 44 Item: 6 OVERHEADDOORCONDITION

The swing arm is detached from the door track. This preventsthe door from raising and lowering. Recommend qualifiedcontractor repair as needed.

One of the tension springs is broken. As a result, the weightof the overhead door could cause damage to the opener.Recommend qualified contractor examine and repair asneeded.

Swing arm detached Tension springs broken

Page 44 Item: 9 FIREWALL The holes in the ceiling and walls compromise the integrity ofthe firewall between the garage and interior living spaces.Potential safety hazard. Building codes require all garageceilings and any wall that abuts a living space to be finishedand free of holes. Recommend qualified contractor repair withfire rated drywall, tape, and mud.

Page 13: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 12 of 96

Firewall compromised Firewall compromised

Firewall compromised Firewall compromised

Firewall compromised Firewall compromised by unused dryer vent

KITCHEN

Page 14: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 13 of 96

Page 49 Item: 1 ELECTRICAL Although not required when the home was built, recommendinstalling GFCI outlets in the kitchen to reduce the risk ofshock.

Page 49 Item: 5 STOVE The stove is not equipped with an anti-tip bracket. Potentialsafety hazard. When installed, this device prevents the stovefrom tipping forward when weight is placed on an open ovendoor. Recommend qualified contractor install.

Page 50 Item: 10 REFRIGERATOR There is no water supply line extending to the refrigerator.This renders the ice maker inoperable. Recommend qualifiedcontractor install a water line as needed.

UPPER LEVEL MASTER BATHPage 53 Item: 2 ELECTRICAL

OUTLET(S)The bathroom outlet has an open ground. Potential safetyhazard. Recommend licensed electrician examine and repairas needed.

Page 53 Item: 4 SINK(S) The sink stopper is missing. Recommend installing orreplacing as needed.

Page 53 Item: 6 SHOWER The grout between some of the shower tiles is cracked anddeteriorated. Recommend qualified contractor grout and/orseal to prevent moisture intrusion and damage to the wallboard behind the tiles.

Missing grout Missing grout

Page 54 Item: 10 CABINET(S) One or more of the drawers are damaged and/or missing.Recommend qualified contractor examine and repair orreplace as needed.

Page 15: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 14 of 96

Drawers damaged and/or missing

Page 55 Item: 16 CEILING ANDWALLS

There is a hole in the wall behind the entry door. Recommendqualified contractor repair, prep, and paint as needed.

Hole in wall behind entry door

UPPER LEVEL GUEST BATHPage 56 Item: 4 SINK(S) There is a constant drip at the sink faucet. Recommend

licensed plumber or qualified contractor repairing as needed.

The sink stopper is missing. Recommend installing orreplacing as needed.

Page 16: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 15 of 96

Constant drip at sink faucet

Page 57 Item: 6 SHOWER The grout between some of the shower tiles is cracked anddeteriorated. Recommend qualified contractor grout and/orseal to prevent moisture intrusion and damage to the wallboard behind the tiles.

Missing grout

Page 57 Item: 7 TOILET The toilet bowl is loose. Movement could cause the wax sealto break and leak. Recommend securing and/or repairing asneeded.

LOWER LEVEL BATHPage 59 Item: 4 SINK(S) The tail piece (e.g. vertical pipe between the sink basin and

“P” trap) is comprised of corrugated flexible piping. This typeof drain pipe is not permitted by Uniform Plumbing Codes as itis susceptible to blockages. Recommend licensed plumber orqualified contractor repair as needed.

Page 17: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 16 of 96

Corrugated piping

Page 60 Item: 7 TOILET The toilet bowl is loose. Movement could cause the wax sealto break and leak. Recommend securing and/or repairing asneeded.

MAIN LEVEL LIVING ROOMPage 62 Item: 5 CLOSET(S) The closet doors have been removed. Recommend installing

or replacing as needed.UPPER LEVEL BEDROOM - NW CORNERPage 66 Item: 5 CLOSET(S) The closet doors have been removed. Recommend installing

or replacing as needed.Page 66 Item: 7 CEILING AND

WALLSThere is a hole in the wall behind the entry door. Recommendqualified contractor repair, prep, and paint as needed.

LOWER LEVEL FAMILY ROOMPage 70 Item: 2 ELECTRICAL The outlet on the south wall has reverse polarity (hot and

neutral wires reversed). Potential safety hazard.Recommend licensed electrician repair.

The cover on the ceiling light is missing. Recommendinstalling or replacing as needed.

Cover missing on ceiling light

Page 18: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 17 of 96

Page 71 Item: 7 CEILING ANDWALLS

There is moisture damage visible on the ceiling. Recommendqualified contractor repair, prep, and paint as needed.

Moisture stains and damage visible on family room ceiling

Page 71 Item: 8 FLOORCOVERING

The carpet is loose and buckled in several locations.Recommend qualified contractor stretch and secure asneeded.

BASEMENT BEDROOM - SW CORNERPage 72 Item: 2 ELECTRICAL There are no outlets on the north and east walls. An

insufficient number of outlets could lead to the unsafesubstitution of extension cord wiring for permanent wiring.Current electrical codes require outlets every 12’ on interiorwalls and at least one outlet on walls greater than or equal to2’. Recommend licensed electrician repair as needed.

The outlet on the south wall is loose. Movement could resultin loose connections and overheating. Potential safetyhazard. Recommend repairing and/or securing as needed.

Page 72 Item: 4 DOOR(S) The entry door is not equipped with hardware. This preventsthe door from closing securely. Recommend installing asneeded.

Page 72 Item: 5 CLOSET(S) The closet doors have been removed. Recommend installingor replacing as needed.

BASEMENT BEDROOM - SE CORNERPage 74 Item: 2 ELECTRICAL There are no outlets on the east wall. An insufficient number

of outlets could lead to the unsafe substitution of extensioncord wiring for permanent wiring. Current electrical codesrequire outlets every 12’ on interior walls and at least oneoutlet on walls greater than or equal to 2’. Recommendlicensed electrician repair as needed.

Page 74 Item: 5 CLOSET(S) The closet doors have been removed. Recommend installingor replacing as needed.

BASEMENT BEDROOM - EAST FACING

Page 19: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 18 of 96

Page 76 Item: 2 ELECTRICAL There are no outlets on the east and west walls. Aninsufficient number of outlets could lead to the unsafesubstitution of extension cord wiring for permanent wiring.Current electrical codes require outlets every 12’ on interiorwalls and at least one outlet on walls greater than or equal to2’. Recommend licensed electrician repair as needed.

Page 76 Item: 4 DOOR(S) The entry door strikes the casing. This makes it difficult toopen and close the door. Recommend qualified contractorevaluate and repair as needed.

Page 76 Item: 5 CLOSET(S) The closet doors have been removed. Recommend installingor replacing as needed.

INTERIOR AREASPage 78 Item: 1 STAIRS The stairs extending to the lower level are not equipped with a

handrail. Potential safety hazard. Current building codesrequired a handrail to be installed 34" - 38" above the stairtreads. Recommend qualified contractor install as needed.

The carpet on the bottom treads has been removed.Recommend replacing as needed.

The stairs extending to the basement are not equipped with ahandrail. Potential safety hazard. Current building codesrequired a handrail to be installed 34" - 38" above the stairtreads. Recommend qualified contractor install as needed.

The carpet on the basement stairs is damaged. Recommendqualified contractor examine and repair as needed.

Page 20: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 19 of 96

Handrail missing Carpet removed

Handrail missing Carpet damaged

Page 79 Item: 3 FIREPLACE(S) There is soot and/or creosote buildup in the fireplace flue.Potential safety hazard. Recommend licensed chimneysweep clean and examine. (Note: The degree of soot buildupcould conceal cracks and/or other damage in the flue liner.)

Page 79 Item: 4 SMOKE ALARMS The home is not equipped with smoke alarms. Potentialsafety hazard. Building codes require smoke alarms in everybedroom and in the common areas outside the bedrooms(e.g. hallway, living room, etc.). In addition, there must be atleast one smoke alarm on every level of the home, includingthe basement. Recommend qualified contractor install asneeded.

Page 79 Item: 5 CARBONMONOXIDEALARM(S)

The home is not equipped with carbon monoxide alarms.Potential safety hazard. Building codes require an alarm to beinstalled within 15’ of every bedroom. Recommend installingas needed.

ATTIC

Page 21: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 20 of 96

Page 80 Item: 3 INSULATION At a depth of 4" - 6", attic insulation is average for a homebuilt in 1983 but could be improved. Generally, a minimumdepth of 10” – 14” is recommended to attain an “R” value of38. Recommend qualified contractor evaluate and insulate asneeded.

Page 80 Item: 4 VENTILATION The attic is equipped with roof vents only. Typically, homesare equipped with a combination of high and low venting (e.g.roof and soffit vents, gable and soffit vents, ridge and soffitvents, ridge and gable vents, etc.) to encourage convective airmovement through the attic. Insufficient ventilation can (1)reduce the life expectancy of the roof covering; (2) make itdifficult to cool the home during the warm summer months;and (3) cause condensation to form in the cold winter months.Recommend qualified contractor evaluate and ventilate asneeded.

Page 81 Item: 8 EXHAUST FAN(S) The fan in the hallway bathroom is exhausted into the attic.Recommend extending the exhaust hose to a vent so thatmoisture is deposited outside.

BASEMENTPage 82 Item: 1 PERMIT The basement was finished after the home was constructed;

however, there is no permit on file with the buildingdepartment. Recommend obtaining a retroactive permit toensure the basement complies with applicable building codes.

PLUMBING - WATER HEATERPage 84 Item: 3 AGE The water heater 12 years old. The average life expectancy

for a gas fired water heater is 8 - 12 years. Althoughfunctioning at the time of the inspection, the water heatercould be nearing the end of its useful life.

Page 85 Item: 9 STORAGE TANK There is rust and corrosion visible around the water inlet ontop of the tank. Although there were no leaks visible at thetime of the inspection, the inlet could begin leaking at anytime. Recommend licensed plumber or qualified contractorexamine and repair as needed.

Rust and corrosion around water inlet

Page 22: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 21 of 96

Page 85 Item: 10 COMBUSTIONAIR

The utility room is not equipped with suffuicient combustionair. Insufficient combustion air can cause back venting in theflue pipe, allowing combustible byproducts (including carbonmonoxide) to enter the home. Potential safety hazard.Recommend licensed contractor evaluate and ventilate theutility room as needed. This will most likely entail installing alouvered door and/or wall vents.

Inadequate combustion air

Page 86 Item: 12 PERMIT The permit for the water heater is voided. This means thefinal inspection and approval were not completed by thebuilding department. Recommend obtaining a "final" status toensure the water heater complies with applicable plumbingcodes.

Water heater failed final inspection

PLUMBING - OTHERPage 87 Item: 1 WATER

PRESSUREWater pressure, typically set between 50 - 70 psi, is elevatedat 80 psi. Pressure at or above 80 psi can cause damage towater supply piping, valves, and fixtures. Recommendlicensed plumber or qualified contractor evaluate and repairas needed. This will most likely entail adjusting or replacingthe water pressure regulator.

Definition
The ductwork installed to bring fresh outside air to the furnace and/or hot water heater. Normally, two separate supplies of air are brought in: one high and one low.
Definition
The ductwork installed to bring fresh outside air to the furnace and/or hot water heater. Normally, two separate supplies of air are brought in: one high and one low.
Page 23: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 22 of 96

Water pressure too high (80 psi)

Page 88 Item: 4 WATER SUPPLYLINES

The home is equipped with polybutylene water lines.Polybutylene is a form of plastic resin that was usedextensively in the manufacture of water supply piping from1978 until 1995. Due to the low cost of the material and easeof installation, polybutylene piping systems were viewed as"the pipe of the future" and were used as a substitute fortraditional copper piping. However, polybutylene pipes have ahistory of failure and have been the focus of a class actionlawsuit. Typically, the pipes can fail in two ways. First, thepipes can fail at the connectors. Second, it is believed thatoxidants in the public water supplies such as chlorine andfluoride react with the polybutylene pipes causing them toscale, flake, and become brittle. The resulting micro-fracturescan reduce the basic structural integrity of the system. Thus,the system can become weak and fail without warning yearsafter it was installed. Recommend licensed plumber orqualified contractor evaluate and replace as needed.

Polybutylene water lines Polybutylene water lines

HEATING - FURNACE

Page 24: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 23 of 96

Page 90 Item: 2 AGE The furnace is 18 years old. The average life expectancy fora gas fired forced air furnace is 15 - 25 years. Althoughfunctioning at the time of the inspection, the furnace could benearing the end of its useful life.

Page 90 Item: 5 FURNACE The furnace is very dirty and does not appear to have beencleaned and serviced in number of years. Recommendlicensed HVAC technician clean and service.

Page 90 Item: 7 PERMIT The furnace is not permitted. Typically, we would recommendobtaining a retroactive permit to ensure the furnace complieswith applicable HVAC codes. However, this may not bereasonable or feasible given the amount of time that haslapsed (18 years) since the furnace was installed.Recommend consulting the building department.

COOLING - AIR CONDITIONERPage 91 Item: 1 COOLING

SYSTEMThe air conditioner is 8 years old. The average lifeexpectancy for a central air conditioning system is 10 – 15years. Although functioning at the time of the inspection, thecooling system could be nearing the end of its useful life.

Page 91 Item: 2 CONDENSINGUNIT

The condenser fins are dirty. The purpose of the condenserfins is to dissipate the heat from the coolant that flows throughthe coil. Even a modest amount of dirt and debris cansignificantly reduce the efficiency of the cooling system.Recommend licensed HVAC technician clean and service.

Page 91 Item: 3 REFRIGERANTLINES

The insulation on the refrigerant lines is missing. Inadequateor missing insulation can cause the refrigerant lines to gainheat from ambient air. This causes the compressor to operateless efficiently. Recommend installing as needed.

Insulation on refrigerant lines missing Insulation on refrigerant lines missing

ELECTRICALPage 94 Item: 1 MAIN PANEL • There are “knock outs” missing in the panel cover. Potential

safety hazard. This is where circuits are no longer used andthe breakers have been removed but the openings in thepanel have not been covered. All openings in the panel covershould be sealed as there is still power flowing to the area andtouching it could result in a severe shock. Recommendinstalling covers.

Page 25: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 24 of 96

Knockouts missing in panel cover

Page 26: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 25 of 96

INSPECTION SITE AND DETAILS INTRODUCTION: We appreciate the opportunity to conduct this inspection for you!   Please carefully read your entireInspection Report.  Call us after you have reviewed your report, so we can go over any questionsyou may have.  Remember, when the inspection is completed and the report is delivered, we are stillavailable to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail.” -  The following report is based on an inspectionof the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFCI outlets may not be installed; thisreport will focus on safety and function, not current code. This report identifies specific non-code,non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repairany critical concerns and defects.  Note that this report is a snapshot in time. We recommend thatyou or your representative carry out a final walk-through inspection immediately before closing tocheck the condition of the property, using this report as a guide.

1. AttendeesIn Attendance: Inspector only

2. OccupancyOccupancy: Occupied - Heavy volume of personal and household items observed. • Access tosome items such as electrical outlets, windows, wall/floor surfaces, and cabinet interiors wasrestricted by furniture, storage items, and/ or personal belongings. As a result, those items couldnot be inspected and are excluded from the report.

3. Type and Style of HomeHome Type: Single Family Home; Split-Level

4. Orientation of HomeMaterials: Front of Home Faces West

5. Type and Style of GarageMaterials: Built-In; 1-Car • Detached; 1-Car

Page 27: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 26 of 96

ROOF As with all areas of the house, we recommend that you carefully examine the roof immediately priorto closing the deal. Note that walking on a roof voids some manufacturer’s warranties. Adequateattic ventilation, solar / wind exposure, and organic debris all affect the life expectancy of a roof. Always ask the seller about the age and history of the roof. On any home that is over 3 years old,experts recommend that you obtain a roof certification from an established local roofing company todetermine its serviceability and the number of layers on the roof. We certainly recommend this forany roof over 5 years of age. Metal roofs in snow areas often do not have gutters and downspouts,as there is a concern that snow or ice cascading off the roof may tear gutters from the house. Likewise, be advised that such cascading may cause personal injury or even death. If this househas a metal roof, consult with qualified roofers or contractors regarding the advisability of installing adamming feature which may limit the size and amount of snow / ice sliding from the roof. 1. ROOF CONDITIONMaterials:

The asphalt shingles were inspected from the roof.Observations:

Permit data on file with the Pikes Peak Regional Building Department shows the roof was installedin January 2008. The permit has a "final" status meaning the final inspection and approval werecompleted by the building department.

The roof is in serviceable condition. There are no signs of hail or wind damage. There are also nosigns of product or installation defects.

The roof exhibits wear and granule loss consistent with age. There are no signs of hail damage.There are also no signs of product or installation defects. However, there are several damagedshingles visible on the roof. Recommend licensed roofer or qualified contractor examine and repairas needed.

Damaged shingles Damaged shingles

Page 28: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 27 of 96

Damaged shingles Damaged shingles2. FLASHINGObservations:

The roof flashing is adequate and there are no signs of adverse conditions.

3. PLUMBING VENTSObservations:

The pipe jacks around the plumbing vents are damaged and/or deteriorated. The resulting gapsaround the base of the vent pipes could be susceptible to moisture intrusion. Recommend licensedroofer repair or replace to prevent leaks and possible damage.

One of the plumbing vents on an east facing slope does not extend at least 6" above the roof asrequired. Code requires plumbing vents to terminate at least 6" above the roof or above the snowdepth that usually collects on the roof, whichever is higher. This is to ensure the plumbing does notbecome blocked with snow and ice. Blocked vents could cause sewer gases to enter the home.Recommend licensed plumber or qualified contractor examine and repair as needed.

Plumbing vent too low Pipe jack around plumbing vent damaged

Page 29: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 28 of 96

Pipe jack around plumbing vent damaged Pipe jack around plumbing vent damaged4. GAS VENTSObservations:

The gas vent is in good condition. More specifically, the gas vent is free of rust, corrosion, and/ordamage. In addition, the gas vent stack is equipped with a storm collar that is adequately sealed.Finally, the gas vent cap is present and free of damage.

5. OTHER VENTSObservations:

The roof vents are in serviceable condition. There are no signs of hail or wind damage. There arealso no signs of product or installation defects.

6. CHANNELSObservations:

The roof to wall channel on the west facing slope is not adequate. This could cause water to dambehind the shingles and/or flashing resulting in roof leaks. Recommend licensed roofer or qualifiedcontractor examine and repair as needed.

Roof to wall channel inadequate

Page 30: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 29 of 96

7. VALLEYSObservations:

The valleys are not visible (e.g. covered by asphalt shingles).

8. CHIMNEY CRICKETObservations:

The roof is equipped with a chimney cricket. A chimney cricket is designed to divert water, snow,and debris around the chimney. It is typically installed on roofs where the width of the chimney isgreater than 30". When the chimney is at the bottom of a roof slope, moisture and debris canaccumulate behind the chimney. This can cause moisture from rain and melting snow to work itsway under the shingles and leak into the home. At the time of the inspection, the chimney cricketwas in satisfactory condition and there were no signs of water intrusion and/or damage.

9. SKYLIGHTSObservations:

N/A.

10. GUTTERSObservations:

The gutters are dirty. Standing water could lead to rusting and leaking over an extended period.Recommend cleaning to ensure adequate water flow to the downspouts.

The downspouts are not equipped with extensions. Water deposited next to the home can exerthydrostatic pressure on the foundation walls and could result in a wet basement or crawlspace.Recommend installing extensions so that water runoff is carried at least 4' away from the structure.

Downspout extension missing Downspout extension missing

Definition
The internal angle formed by the junction of two sloping sides of a roof.
Page 31: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 30 of 96

Downspout extension missing Downspout extension missing

Dirty gutter Dirty gutter

Page 32: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 31 of 96

CHIMNEY 1. CHIMNEY CONDITIONObservations:• The concrete chimney cap is cracked and damaged. Recommend qualified contractor repair orreplace as needed.

Chimney cap cracked and damaged

Page 33: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 32 of 96

EXTERIOR CLADDING, WINDOWS, ANDDOORS This section describes the exterior wall coverings and trim. Inspectors are required to inspect theexterior wall coverings, flashing, trim, all exterior doors, the stoops, steps porches and theirassociated railings, any attached decks and balconies and eaves, soffits and fascias accessible fromground level.

1. EXTERIOR CLADDINGMaterials:

The home is equipped with a combination of brick veneer and masonite siding over wood framing.At the time of the inspection, the exterior cladding was being prepped and painted by a contractor.Observations:

There is moisture damage visible on one of the east facing lap boards. Recommend qualifiedcontractor repair, prep, and paint as needed.

Damaged siding2. EXTERIOR WINDOW CONDITIONObservations:

The windows are in serviceable condition. There are no signs of peeling paint, wood rot, or otherdamage.

3. EXTERIOR DOOR CONDITIONObservations:

The patio slider is not equipped with a screen. Recommend installing or replacing as needed.

Page 34: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 33 of 96

GROUNDS Inspectors shall inspect adjacent or entryway walkways, patios, and driveways; vegetation, grading,surface drainage, and retaining walls that are likely to adversely affect the building.

1. DRIVEWAYMaterials:

The driveway is comprised of poured concrete.Observations:

There is flaking and deteriorating concrete (known as "spalling") visible in the driveway. Spallingconcrete can only be repaired if a bonding agent is used to ensure the new concrete bonds with theold. Recommend qualified contractor examine and repair or replace as needed.

Spalling concrete Spalling concrete2. SIDEWALKMaterials:

The sidewalk is comprised of poured concrete.Observations:

The sidewalk is in serviceable condition and there are no safety concerns.

3. PATIOObservations:

The concrete slab is in satisfactory. There are no signs of cracks or other damage.

4. PATIO COVERObservations:

N/A.

5. STEPS / STOOPObservations:

The steps are in serviceable condition and there are no safety concerns.

Page 35: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 34 of 96

6. DECKMaterials:

The deck is comprised of wood and composite decking.Observations:

There is moisture damage visible on the deck joists. Recommend qualified contractor examine andrepair as needed.

The guardrails around the perimeter of the deck are loose. Potential safety hazard. Recommendqualified contractor examine and repair as needed.

There is significant moisture damage visible on the stair stringers. Recommend qualified contractorexamine and repair as needed.

The TREX decking is peeling and deteriorating. Recommend qualified contractor examine andrepair as/if needed.

Wood rot on deck joist Wood rot on deck joist

Wood rot on deck joist Wood rot on deck joist

Page 36: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 35 of 96

Wood rot on stair stringer Wood rot on stair stringer

Wood rot on stair stringer Wood rot on stair stringer7. FENCEMaterials:

The privacy fence is comprised of wood.Observations:

There are numerous broken, damaged, and/or loose pickets. Recommend replacing or securing asneeded.

There are several damaged and/or detached fence rails. Recommend repairing and/or securing asneeded.

Some of the posts do not appear to be set in concrete. Posts set in the ground are susceptible tomoisture damage. At the time of the inspection, several broken posts were observed. Recommendqualified contractor examine and repair as needed.

Page 37: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 36 of 96

Detached fence rail Broken fence post8. GRADINGObservations:

There is negative grading on the south and east sides of the home. Moisture pooling next to astructure can exert hydrostatic pressure on the foundation walls and could result in a wet basementor crawlspace. Recommend qualified contractor evaluate and mitigate as needed. This will mostlikely entail adding backfill and/or regrading to create the proper pitch so that moisture is divertedaway from the structure. Proper pitch is generally considered 1" drop per foot for 5' - 6'.

Negative grading east side of home Negative grading on south side of home9. TREES / VEGETATIONObservations:

There are no trees or vegetation in close proximity to the structure.

10. RETAINING WALLObservations:

The retaining wall is in serviceable condition and there are no signs of damage.

Page 38: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 37 of 96

11. WINDOW WELLSObservations:

The window well on the south side of the home does not appear to be deep enough. As a result,the basement could be susceptible to moisture intrusion during heavy rains or snows. Generally,there should be at least 6” of rock in the base of the window well and at least 3” between the top ofthe rock and the bottom of the window. Recommend deepening the window well or installing aplastic cover to minimize the amount of moisture entering the window well.

Window well too shallow12. HOSE BIBSLocation:

There are hose bibs installed on the south, east, and west sides of the home.Observations:

The hose bib on the west side of the home is not equipped with an anti-siphon valve. This type ofvalve prevents irrigation and/or dirty water from entering the home’s drinking supply. Although notrequired when this home was built, recommend licensed plumber or qualified contractor install.

The knob on the south facing hose bib is damaged or missing. This makes opening and closing thevalve very difficult. Recommend repairing as needed.

Page 39: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 38 of 96

Knob on south facing hose bib is missing13. SPRINKLER SYSTEMObservations:

The home is equipped with an underground sprinkler system. Because the majority of thecomponents are located below grade and not readily visible, the sprinkler system is outside thescope of the home inspection. Recommend qualified contractor examine the system and repairas/if needed. This should also include familiarizing the client with operating instructions andwinterizing procedures.

Page 40: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 39 of 96

EXTERIOR ELECTRICAL 1. EXTERIOR ELECTRICALObservations:• The duplex outlet above the patio on the east side of the home is inoperable. At the time of theinspection, there were no breakers tripped in the electrical panel. In addition, there were no GFCIoutlets tripped in the home or garage. Recommend licensed electrician repair as needed.• The outlets on the west side of the home are not GFCI protected. Potential safety hazard.Recommend licensed electrician repair.

2. SERVICE ENTRANCEObservations:• There are no adverse conditions.

Definition
A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system.
Page 41: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 40 of 96

GAS METER 1. GAS METER AND SHUTOFF VALVEMaterials:

The gas meter and main shutoff valve are located on the south facing exterior wall.Observations:

The gas meter and shutoff valve are in satisfactory condition. There are no gas leaks or or anyother adverse conditions.

2. GAS LINE (EXTERIOR)Observations:

N/A.

Page 42: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 41 of 96

DETACHED GARAGE 1. ROOF CONDITIONMaterials:

The roof over the garage is the same as the home. (See "Roof" Section of this report for details.)

2. GUTTERSObservations:

The gutters on the garage are the same as the home. (See "Roof" Section of this report fordetails.)

3. EXTERIOR CLADDING CONDITIONMaterials:

The exterior cladding on the garage is the same as the home. (See "Exterior Cladding" Section ofthis report for details.)

4. LANDSCAPINGObservations:

N/A.

5. ELECTRICALObservations:

There are no adverse conditions.

6. OVERHEAD DOOR CONDITIONMaterials:

The garage is equipped with metal overhead doors.Observations:

The overhead doors are in good condition and functioned properly during testing.

7. OVERHEAD DOOR OPENERObservations:

N/A.

8. OVERHEAD DOOR OPENER SAFETY FEATURESObservations:

N/A.

9. FIREWALLObservations:

The firewall between the garage and interior living spaces is present and free of damage.

Page 43: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 42 of 96

10. ANCHOR BOLTSObservations:

The anchor bolts that secure the framing members (e.g. sill plate, studs, and top plate) to thefoundation walls are concealed by drywall. This prevented us from inspecting the anchor bolts.

11. FLOOR CONDITIONObservations:

The concrete floor slab is in good condition.

12. SERVICE DOORObservations:

The garage service door is in good condition.

13. ENTRY DOOR FROM GARAGEObservations:

The entry door from the garage is in good condition.

14. FRAMING AND INSULATIONObservations:

There is insulation installed between the wall studs in the garage. The insulation is installed withthe flammable paper facing exposed. Potential safety hazard. There is a warning label on theinsulation that indicates the facing is flammable and should be covered with gypsum board or otherapproved building material. Recommend covering to ensure the garage is safe.

Flammable paper facing exposed15. UTILITY SINKObservations:

N/A.

Page 44: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 43 of 96

ATTACHED GARAGE 1. ROOF CONDITIONMaterials:

The roof over the garage is the same as the home. (See "Roof" Section of this report for details.)

2. GUTTERSObservations:

The gutters on the garage are the same as the home. (See "Roof" Section of this report fordetails.)

3. EXTERIOR CLADDING CONDITIONMaterials:

The exterior cladding on the garage is the same as the home. (See "Exterior Cladding" Section ofthis report for details.)

4. LANDSCAPINGObservations:

N/A.

5. ELECTRICALObservations:

The 4-plex outlet on the south wall is not GFCI protected as required. Potential safety hazard.When this home was built, electrical codes required all garage outlets to be GFCI protected exceptif (1) the receptacles were not readily accessible (e.g. a ceiling outlet powering an overhead dooropener); or (2) the outlets were single receptacles designated for equipment not easily moved (e.g.freezer); or (3) the outlets were duplex receptacles that were designated for two fixed appliances.Since this outlet does not meet these criteria, recommend licensed electrician repair.

There is exposed Romex wiring on the south wall. Potential safety hazard. Recommend licensedelectrician repair. This will most likely entail enclosing the wiring in conduit.

Exposed Romex wiring

Page 45: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 44 of 96

6. OVERHEAD DOOR CONDITIONMaterials:

The garage is equipped with a wooden overhead door.Observations:

The swing arm is detached from the door track. This prevents the door from raising and lowering.Recommend qualified contractor repair as needed.

One of the tension springs is broken. As a result, the weight of the overhead door could causedamage to the opener. Recommend qualified contractor examine and repair as needed.

Swing arm detached Tension springs broken7. OVERHEAD DOOR OPENERObservations:

Not tested. Unit disconnected from power source and overhead door.

8. OVERHEAD DOOR OPENER SAFETY FEATURESObservations:

Not tested.

9. FIREWALLObservations:

The holes in the ceiling and walls compromise the integrity of the firewall between the garage andinterior living spaces. Potential safety hazard. Building codes require all garage ceilings and anywall that abuts a living space to be finished and free of holes. Recommend qualified contractorrepair with fire rated drywall, tape, and mud.

Page 46: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 45 of 96

Firewall compromised Firewall compromised

Firewall compromised Firewall compromised

Firewall compromised Firewall compromised by unused dryer vent

Page 47: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 46 of 96

10. ANCHOR BOLTSObservations:

The anchor bolts that secure the framing members (e.g. sill plate, studs, and top plate) to thefoundation walls are concealed by drywall. This prevented us from inspecting the anchor bolts.

11. FLOOR CONDITIONObservations:

The concrete floor slab is in good condition.

12. SERVICE DOORObservations:

The garage service door is in good condition.

13. ENTRY DOOR FROM GARAGEObservations:

The entry door from the garage is in good condition.

14. FRAMING AND INSULATIONObservations:

The wood framing members (e.g. trusses, top plates, studs, and sill plates) are in good conditionand adequately transferring the home's loads to the foundation walls and footings.

15. UTILITY SINKObservations:

N/A.

Page 48: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 47 of 96

OFFICE IN ATTACHED GARAGE 1. LOCATIONLocations:

Attached Garage

2. ELECTRICALObservations:

The outlets and switches are wired correctly and there are no adverse conditions.

3. EGRESSObservations:

N/A.

4. DOOR(S)Observations:

The doors are in satisfactory condition.

5. CLOSET(S)Observations:

N/A.

6. WINDOW(S)Materials:

The room is equipped with vinyl windows.Observations:

The windows are in good condition.

7. CEILING AND WALLSObservations:

The ceiling and walls are in good condition.

8. FLOOR COVERINGFlooring Types:

The room is equipped with carpet over a concrete slab.Observations:

The floor covering is in serviceable condition.

9. HEAT SOURCEObservations:

The room is equipped with a heat source that appears to be in serviceable condition.

Page 49: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 48 of 96

10. PERMITObservations:

The attached garage was partially converted into an office space in June 2007. The permit has afinal status indicating the conversion complied with applicable building codes.

Page 50: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 49 of 96

KITCHEN The kitchen is used for food preparation and often for entertainment. Kitchens typically include astove, dishwasher, sink and other appliances.

1. ELECTRICALObservations:

Although not required when the home was built, recommend installing GFCI outlets in the kitchen toreduce the risk of shock.

2. SINK(S)Observations:

The kitchen sink functioned properly during testing and there were no adverse conditions.

3. DISPOSALObservations:

The disposal functioned properly during testing. There were no signs of rust, corrosion, or leaks.

4. DISHWASHERObservations:

The dishwasher functioned properly during testing and there were no adverse conditions.

5. STOVEObservations:

The stove is not equipped with an anti-tip bracket. Potential safety hazard. When installed, thisdevice prevents the stove from tipping forward when weight is placed on an open oven door.Recommend qualified contractor install.

6. MICROWAVEObservations:

The microwave functioned properly during testing and there were no adverse conditions.

7. COOKTOPObservations:

N/A.

8. OVENObservations:

The double ovens functioned properly during testing and there were no signs of adverse conditions.

9. EXHAUST FANObservations:

N/A.

Page 51: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 50 of 96

10. REFRIGERATORObservations:

There is no water supply line extending to the refrigerator. This renders the ice maker inoperable.Recommend qualified contractor install a water line as needed.

11. TRASH COMPACTORObservations:

N/A.

12. CABINETSObservations:

The cabinets are in serviceable condition.

13. COUNTERTOPSObservations:

The countertops are in serviceable condition.

14. FLOOR COVERINGMaterials:

The kitchen is equipped with wood flooring.Observations:

The floor covering is in serviceable condition.

15. WINDOW(S)Observations:

The kitchen window functioned properly during testing and there were no adverse conditions.

16. CEILING AND WALLSObservations:

The ceiling and walls are in good condition.

Page 52: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 51 of 96

LAUNDRY ROOM 1. LOCATIONLocations:

The laundry room is located on the lower level.

2. ELECTRICALObservations:

The laundry room outlet is wired correctly and there are no adverse conditions.

3. GAS SUPPLYObservations:

N/A.

4. WASHERObservations:

The washer was not tested.

5. DRYERObservations:

The dryer was not tested.

6. LAUNDRY SINKObservations:

N/A.

7. EXHAUST FANObservations:

N/A.

8. CABINET(S)Observations:

N/A.

9. COUNTERTOP(S)Observations:

N/A.

10. FLOOR COVERINGMaterials:

The laundry room is equipped with vinyl flooring.Observations:

The floor covering is in serviceable condition.

Page 53: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 52 of 96

11. DOOR(S)Observations:

The doors are in serviceable condition.

12. WINDOW(S)Observations:

N/A.

13. CEILING AND WALLSObservations:

The ceiling and walls are in good condition.

Page 54: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 53 of 96

UPPER LEVEL MASTER BATH 1. LOCATIONLocations:

Upper Level

2. ELECTRICAL OUTLET(S)Observations:

The bathroom outlet has an open ground. Potential safety hazard. Recommend licensedelectrician examine and repair as needed.

3. ELECTRICAL (OTHER)Observations:

There are no adverse conditions.

4. SINK(S)Observations:

The sink stopper is missing. Recommend installing or replacing as needed.

5. TUBObservations:

The tub functioned properly during testing and there were no adverse conditions.

6. SHOWERObservations:

The grout between some of the shower tiles is cracked and deteriorated. Recommend qualifiedcontractor grout and/or seal to prevent moisture intrusion and damage to the wall board behind thetiles.

Missing grout Missing grout

Page 55: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 54 of 96

7. TOILETObservations:

The toilet functioned properly during testing and there were no adverse conditions.

8. EXHAUST FANObservations:

The exhaust fan functioned properly during testing and there were no adverse conditions.

9. HEAT SOURCEObservations:

The bathroom is equipped with a heat source that appeared to be in serviceable condition.

10. CABINET(S)Observations:

One or more of the drawers are damaged and/or missing. Recommend qualified contractorexamine and repair or replace as needed.

Drawers damaged and/or missing11. COUNTERTOP(S)Observations:

The countertop is in good condition.

12. MIRROR(S)Observations:

The mirror is in good condition.

Page 56: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 55 of 96

13. FLOOR COVERINGMaterials:

The bathroom is equipped with vinyl flooring.Observations:

The floor covering is in serviceable condition.

14. DOOR(S)Observations:

The door is in satisfactory condition.

15. WINDOW(S)Observations:

N/A.

16. CEILING AND WALLSObservations:

There is a hole in the wall behind the entry door. Recommend qualified contractor repair, prep, andpaint as needed.

Hole in wall behind entry door

Page 57: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 56 of 96

UPPER LEVEL GUEST BATH 1. LOCATIONLocations:

Upper Level

2. ELECTRICAL OUTLET(S)Observations:

The bathroom outlet is wired correctly and adequately protected.

3. ELECTRICAL (OTHER)Observations:

There are no adverse conditions.

4. SINK(S)Observations:

There is a constant drip at the sink faucet. Recommend licensed plumber or qualified contractorrepairing as needed.

The sink stopper is missing. Recommend installing or replacing as needed.

Constant drip at sink faucet5. TUBObservations:

The tub functioned properly during testing and there were no adverse conditions.

6. SHOWERObservations:

The grout between some of the shower tiles is cracked and deteriorated. Recommend qualifiedcontractor grout and/or seal to prevent moisture intrusion and damage to the wall board behind thetiles.

Page 58: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 57 of 96

Missing grout Missing grout7. TOILETObservations:

The toilet bowl is loose. Movement could cause the wax seal to break and leak. Recommendsecuring and/or repairing as needed.

8. EXHAUST FANObservations:

The exhaust fan functioned properly during testing and there were no adverse conditions.

9. HEAT SOURCEObservations:

The bathroom is equipped with a heat source that appeared to be in serviceable condition.

10. CABINET(S)Observations:

The cabinet is secured to the wall and in serviceable condition.

11. COUNTERTOP(S)Observations:

The countertop is in good condition.

12. MIRROR(S)Observations:

The mirror is in good condition.

Page 59: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 58 of 96

13. FLOOR COVERINGMaterials:

The bathroom is equipped with vinyl flooring.Observations:

The floor covering is in serviceable condition.

14. DOOR(S)Observations:

The door is in satisfactory condition.

15. WINDOW(S)Observations:

N/A.

16. CEILING AND WALLSObservations:

The ceiling and walls are in good condition.

Page 60: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 59 of 96

LOWER LEVEL BATH 1. LOCATIONLocations:

Lower Level

2. ELECTRICAL OUTLET(S)Observations:

The bathroom outlet is wired correctly and adequately protected.

3. ELECTRICAL (OTHER)Observations:

There are no adverse conditions.

4. SINK(S)Observations:

The tail piece (e.g. vertical pipe between the sink basin and “P” trap) is comprised of corrugatedflexible piping. This type of drain pipe is not permitted by Uniform Plumbing Codes as it issusceptible to blockages. Recommend licensed plumber or qualified contractor repair as needed.

Corrugated piping5. TUBObservations:

N/A.

6. SHOWERObservations:

N/A.

Page 61: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 60 of 96

7. TOILETObservations:

The toilet bowl is loose. Movement could cause the wax seal to break and leak. Recommendsecuring and/or repairing as needed.

8. EXHAUST FANObservations:

The exhaust fan functioned properly during testing and there were no adverse conditions.

9. HEAT SOURCEObservations:

The bathroom is equipped with a heat source that appeared to be in serviceable condition.

10. CABINET(S)Observations:

The cabinet is secured to the wall and in serviceable condition.

11. COUNTERTOP(S)Observations:

The countertop is in serviceable condition.

12. MIRROR(S)Observations:

The mirror is in good condition.

13. FLOOR COVERINGMaterials:

The bathroom is equipped with tile flooring.Observations:

The floor covering is in good condition.

14. DOOR(S)Observations:

The door is in satisfactory condition.

15. WINDOW(S)Observations:

N/A.

16. CEILING AND WALLSObservations:

The ceiling and walls are in good condition.

Page 62: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 61 of 96

MAIN LEVEL DINING ROOM 1. LOCATIONLocations:

Main Level

2. ELECTRICALObservations:

The outlets and switches are wired correctly and there are no adverse conditions.

3. EGRESSObservations:

N/A.

4. DOOR(S)Observations:

N/A.

5. CLOSET(S)Observations:

N/A.

6. WINDOW(S)Observations:

N/A.

7. CEILING AND WALLSObservations:

The ceiling and walls are in good condition.

8. FLOOR COVERINGFlooring Types:

The room is equipped with wood flooring.Observations:

The floor covering is in serviceable condition.

9. CEILING FANObservations:

N/A.

10. HEAT SOURCEObservations:

The room is equipped with a heat source that appears to be in serviceable condition.

Page 63: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 62 of 96

MAIN LEVEL LIVING ROOM 1. LOCATIONLocations:

Main Level

2. ELECTRICALObservations:

The outlets and switches are wired correctly and there are no adverse conditions.

3. EGRESSObservations:

N/A.

4. DOOR(S)Observations:

N/A.

5. CLOSET(S)Observations:

The closet doors have been removed. Recommend installing or replacing as needed.

6. WINDOW(S)Materials:

The room is equipped with vinyl windows.Observations:

The windows are in good condition.

7. CEILING AND WALLSObservations:

The ceiling and walls are in good condition.

8. FLOOR COVERINGFlooring Types:

The room is equipped with wood flooring.Observations:

The floor covering is in serviceable condition.

9. CEILING FANObservations:

N/A.

Page 64: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 63 of 96

10. HEAT SOURCEObservations:

The room is equipped with a heat source that appears to be in serviceable condition.

Page 65: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 64 of 96

UPPER LEVEL MASTER BEDROOM 1. LOCATIONLocations:

Upper Level

2. ELECTRICALObservations:

The outlets and switches are wired correctly and there are no adverse conditions.

3. EGRESSObservations:

There are no adverse conditions.

4. DOOR(S)Observations:

The entry door is in satisfactory condition.

5. CLOSET(S)Observations:

The closets are in satisfactory condition.

6. WINDOW(S)Materials:

The room is equipped with a vinyl window.Observations:

The window is in good condition.

7. CEILING AND WALLSObservations:

The ceiling and walls are in good condition.

8. FLOOR COVERINGFlooring Types:

The room is equipped with carpet over a wood sub floor.Observations:

The floor covering is in serviceable condition.

9. CEILING FANObservations:

The ceiling fan functioned properly during testing and there were no signs of adverse conditions.

Page 66: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 65 of 96

10. HEAT SOURCEObservations:

The room is equipped with a heat source that appears to be in serviceable condition.

Page 67: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 66 of 96

UPPER LEVEL BEDROOM - NW CORNER 1. LOCATIONLocations:

Upper Level

2. ELECTRICALObservations:

The outlets and switches are wired correctly and there are no adverse conditions.

3. EGRESSObservations:

There are no adverse conditions.

4. DOOR(S)Observations:

The entry door is in satisfactory condition.

5. CLOSET(S)Observations:

The closet doors have been removed. Recommend installing or replacing as needed.

6. WINDOW(S)Materials:

The room is equipped with a vinyl window.Observations:

The window is in good condition.

7. CEILING AND WALLSObservations:

There is a hole in the wall behind the entry door. Recommend qualified contractor repair, prep, andpaint as needed.

8. FLOOR COVERINGFlooring Types:

The room is equipped with carpet over a wood sub floor.Observations:

The floor covering is in serviceable condition.

9. CEILING FANObservations:

The ceiling fan functioned properly during testing and there were no signs of adverse conditions.

Page 68: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 67 of 96

10. HEAT SOURCEObservations:

The room is equipped with a heat source that appears to be in serviceable condition.

Page 69: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 68 of 96

UPPER LEVEL BEDROOM - SW CORNER 1. LOCATIONLocations:

Upper Level

2. ELECTRICALObservations:

The outlets and switches are wired correctly and there are no adverse conditions.

3. EGRESSObservations:

There are no adverse conditions.

4. DOOR(S)Observations:

The entry door is in satisfactory condition.

5. CLOSET(S)Observations:

The closet is in satisfactory condition.

6. WINDOW(S)Materials:

The room is equipped with a vinyl window.Observations:

The window is in good condition.

7. CEILING AND WALLSObservations:

The ceiling and walls are in good condition.

8. FLOOR COVERINGFlooring Types:

The room is equipped with carpet over a wood sub floor.Observations:

The floor covering is in serviceable condition.

9. CEILING FANObservations:

The ceiling fan functioned properly during testing and there were no signs of adverse conditions.

Page 70: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 69 of 96

10. HEAT SOURCEObservations:

The room is equipped with a heat source that appears to be in serviceable condition.

Page 71: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 70 of 96

LOWER LEVEL FAMILY ROOM 1. LOCATIONLocations:

Lower Level

2. ELECTRICALObservations:

The outlet on the south wall has reverse polarity (hot and neutral wires reversed). Potential safetyhazard. Recommend licensed electrician repair.

The cover on the ceiling light is missing. Recommend installing or replacing as needed.

Cover missing on ceiling light3. EGRESSObservations:

N/A.

4. DOOR(S)Observations:

N/A.

5. CLOSET(S)Observations:

N/A.

6. WINDOW(S)Materials:

The room is equipped with a vinyl window.Observations:

The window is in good condition.

Page 72: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 71 of 96

7. CEILING AND WALLSObservations:

There is moisture damage visible on the ceiling. Recommend qualified contractor repair, prep, andpaint as needed.

Moisture stains and damage visible on family room ceiling8. FLOOR COVERINGFlooring Types:

The room is equipped with carpet over a concrete slab.Observations:

The carpet is loose and buckled in several locations. Recommend qualified contractor stretch andsecure as needed.

9. CEILING FANObservations:

N/A.

10. HEAT SOURCEObservations:

The room is equipped with a heat source that appears to be in serviceable condition.

Page 73: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 72 of 96

BASEMENT BEDROOM - SW CORNER 1. LOCATIONLocations:

Basement

2. ELECTRICALObservations:

There are no outlets on the north and east walls. An insufficient number of outlets could lead to theunsafe substitution of extension cord wiring for permanent wiring. Current electrical codes requireoutlets every 12’ on interior walls and at least one outlet on walls greater than or equal to 2’.Recommend licensed electrician repair as needed.

The outlet on the south wall is loose. Movement could result in loose connections and overheating.Potential safety hazard. Recommend repairing and/or securing as needed.

3. EGRESSObservations:

There are no adverse conditions.

4. DOOR(S)Observations:

The entry door is not equipped with hardware. This prevents the door from closing securely.Recommend installing as needed.

5. CLOSET(S)Observations:

The closet doors have been removed. Recommend installing or replacing as needed.

6. WINDOW(S)Materials:

The room is equipped with a metal window.Observations:

The window is in serviceable condition.

7. CEILING AND WALLSObservations:

The ceiling and walls are in serviceable condition.

8. FLOOR COVERINGFlooring Types:

The room is equipped with carpet over a concrete slab.Observations:

The floor covering is in serviceable condition.

Page 74: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 73 of 96

9. CEILING FANObservations:

N/A.

10. HEAT SOURCEObservations:

The room is equipped with a heat source that appears to be in serviceable condition.

Page 75: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 74 of 96

BASEMENT BEDROOM - SE CORNER 1. LOCATIONLocations:

Basement

2. ELECTRICALObservations:

There are no outlets on the east wall. An insufficient number of outlets could lead to the unsafesubstitution of extension cord wiring for permanent wiring. Current electrical codes require outletsevery 12’ on interior walls and at least one outlet on walls greater than or equal to 2’. Recommendlicensed electrician repair as needed.

3. EGRESSObservations:

There are no adverse conditions.

4. DOOR(S)Observations:

The door is in serviceable condition.

5. CLOSET(S)Observations:

The closet doors have been removed. Recommend installing or replacing as needed.

6. WINDOW(S)Materials:

The room is equipped with a metal window.Observations:

The window is in serviceable condition.

7. CEILING AND WALLSObservations:

The ceiling and walls are in serviceable condition.

8. FLOOR COVERINGFlooring Types:

The room is equipped with carpet over a concrete slab.Observations:

The floor covering is in serviceable condition.

Page 76: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 75 of 96

9. CEILING FANObservations:

N/A.

10. HEAT SOURCEObservations:

The room is equipped with a heat source that appears to be in serviceable condition.

Page 77: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 76 of 96

BASEMENT BEDROOM - EAST FACING 1. LOCATIONLocations:

Basement

2. ELECTRICALObservations:

There are no outlets on the east and west walls. An insufficient number of outlets could lead to theunsafe substitution of extension cord wiring for permanent wiring. Current electrical codes requireoutlets every 12’ on interior walls and at least one outlet on walls greater than or equal to 2’.Recommend licensed electrician repair as needed.

3. EGRESSObservations:

There are no adverse conditions.

4. DOOR(S)Observations:

The entry door strikes the casing. This makes it difficult to open and close the door. Recommendqualified contractor evaluate and repair as needed.

5. CLOSET(S)Observations:

The closet doors have been removed. Recommend installing or replacing as needed.

6. WINDOW(S)Materials:

The room is equipped with a metal window.Observations:

The window is in serviceable condition.

7. CEILING AND WALLSObservations:

The ceiling and walls are in serviceable condition.

8. FLOOR COVERINGFlooring Types:

The room is equipped with carpet over a concrete slab.Observations:

The floor covering is in serviceable condition.

Page 78: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 77 of 96

9. CEILING FANObservations:

N/A.

10. HEAT SOURCEObservations:

The room is equipped with a heat source that appears to be in serviceable condition.

Page 79: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 78 of 96

INTERIOR AREAS The Interior section covers areas of the house that are not considered part of the Bathrooms,Bedrooms, Kitchen or areas covered elsewhere in the report. Interior areas usually consist ofhallways, foyer, and other open areas. Within these areas the inspector is performing a visualinspection and will report visible damage, wear and tear, and moisture problems if seen. Personalitems in the structure may prevent the inspector from viewing all areas on the interior. The inspector does not usually test for mold or other hazardous materials. A qualified expert shouldbe consulted if you would like further testing.

1. STAIRSObservations:

The stairs extending to the lower level are not equipped with a handrail. Potential safety hazard.Current building codes required a handrail to be installed 34" - 38" above the stair treads.Recommend qualified contractor install as needed.

The carpet on the bottom treads has been removed. Recommend replacing as needed.

The stairs extending to the basement are not equipped with a handrail. Potential safety hazard.Current building codes required a handrail to be installed 34" - 38" above the stair treads.Recommend qualified contractor install as needed.

The carpet on the basement stairs is damaged. Recommend qualified contractor examine andrepair as needed.

Handrail missing Carpet removed

Page 80: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 79 of 96

Handrail missing Carpet damaged2. GUARDRAIL(S)Observations:

N/A.

3. FIREPLACE(S)Observations:

There is soot and/or creosote buildup in the fireplace flue. Potential safety hazard. Recommendlicensed chimney sweep clean and examine. (Note: The degree of soot buildup could concealcracks and/or other damage in the flue liner.)

4. SMOKE ALARMSObservations:

The home is not equipped with smoke alarms. Potential safety hazard. Building codes requiresmoke alarms in every bedroom and in the common areas outside the bedrooms (e.g. hallway,living room, etc.). In addition, there must be at least one smoke alarm on every level of the home,including the basement. Recommend qualified contractor install as needed.

5. CARBON MONOXIDE ALARM(S)Observations:

The home is not equipped with carbon monoxide alarms. Potential safety hazard. Building codesrequire an alarm to be installed within 15’ of every bedroom. Recommend installing as needed.

6. BARObservations:

N/A.

Page 81: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 80 of 96

ATTIC This report describes the method used to inspect any accessible attics; and describes the insulationand vapor retarders used in unfinished spaces when readily accessible and the absence of insulationin unfinished spaces at conditioned surfaces. Inspectors are required to inspect insulation and vaporretarders in unfinished spaces when accessible and passive/mechanical ventilation of attic areas, ifpresent.

1. ACCESSObservations:

The attic spaces are accessible through scuttleholes in the main level closet and in one of theupper level guest bedrooms.

2. STRUCTUREObservations:

The structural components in the attic are in satisfactory condition and exhibited no defects ordamage.

3. INSULATIONObservations:

At a depth of 4" - 6", attic insulation is average for a home built in 1983 but could be improved.Generally, a minimum depth of 10” – 14” is recommended to attain an “R” value of 38.Recommend qualified contractor evaluate and insulate as needed.

4. VENTILATIONObservations:

The attic is equipped with roof vents only. Typically, homes are equipped with a combination ofhigh and low venting (e.g. roof and soffit vents, gable and soffit vents, ridge and soffit vents, ridgeand gable vents, etc.) to encourage convective air movement through the attic. Insufficientventilation can (1) reduce the life expectancy of the roof covering; (2) make it difficult to cool thehome during the warm summer months; and (3) cause condensation to form in the cold wintermonths. Recommend qualified contractor evaluate and ventilate as needed.

5. HVAC DUCTSObservations:

N/A.

6. ELECTRICALObservations:

There are no signs of adverse conditions.

7. CHIMNEY(S)Observations:

The chimney chase is not visible and could not be inspected.

Page 82: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 81 of 96

8. EXHAUST FAN(S)Observations:

The fan in the hallway bathroom is exhausted into the attic. Recommend extending the exhausthose to a vent so that moisture is deposited outside.

9. WHOLE HOUSE FANObservations:

N/A.

Page 83: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 82 of 96

BASEMENT 1. PERMITObservations:

The basement was finished after the home was constructed; however, there is no permit on file withthe building department. Recommend obtaining a retroactive permit to ensure the basementcomplies with applicable building codes.

2. FOUNDATIONObservations:

The foundation walls are concealed by drywall, paneling, and/or insulation. As a result, thefoundation walls were not readily visible and could not be inspected from inside the basement.Only the portions of the foundation walls that were visible from the exterior could be inspected.

3. GIRDERS/COLUMNSObservations:

The finished ceiling in the basement concealed the girder. At the time of the inspection, the drywallaround the girder was free of cracks and/or damage and there were no signs of active movement.

4. JOISTSObservations:

The finished ceiling in the basement concealed the joists. At the time of the inspection, the drywallconcealing the joists was free of cracks and/or damage and there were no signs of activemovement.

5. SUB FLOORObservations:

The finished ceiling in the basement concealed the sub floor. At the time of the inspection, thedrywall concealing the sub floor was free of cracks and/or damage.

6. CONCRETE FLOOR SLABSObservations:

The concrete slabs are in good condition and there are no signs of movement or damage.

7. STRUCTURAL FLOOR SYSTEMObservations:

N/A.

8. SUMP PUMPObservations:

N/A.

9. DRAINAGEObservations:

The floor drain is not tested during the home inspection.

Page 84: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 83 of 96

10. ELECTRICALObservations:

N/A.

Page 85: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 84 of 96

PLUMBING - WATER HEATER 1. WATER HEATER TYPEMaterials:

The home is equipped with a gas fired water heater.Materials:

The water heater has a 50 gallon capacity.

2. LOCATIONMaterials:

The water heater is located in the utility room.

3. AGEObservations:

The water heater 12 years old. The average life expectancy for a gas fired water heater is 8 - 12years. Although functioning at the time of the inspection, the water heater could be nearing the endof its useful life.

4. GAS LINEObservations:

There are no adverse conditions.

5. DRAFT DIVERTER AND FLUEObservations:

There are no adverse conditions.

6. CONTROL VALVEObservations:

There are no adverse conditions.

7. BURNER COMPARTMENTObservations:

There are no adverse conditions.

8. PRESSURE RELIEF VALVEObservations:

There are no adverse conditions.

9. STORAGE TANKObservations:

There is rust and corrosion visible around the water inlet on top of the tank. Although there were noleaks visible at the time of the inspection, the inlet could begin leaking at any time. Recommendlicensed plumber or qualified contractor examine and repair as needed.

Page 86: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 85 of 96

Rust and corrosion around water inlet10. COMBUSTION AIRObservations:

The utility room is not equipped with suffuicient combustion air. Insufficient combustion air cancause back venting in the flue pipe, allowing combustible byproducts (including carbon monoxide)to enter the home. Potential safety hazard. Recommend licensed contractor evaluate and ventilatethe utility room as needed. This will most likely entail installing a louvered door and/or wall vents.

Inadequate combustion air11. EXPANSION TANKObservations:

N/A.

12. PERMITObservations:

The permit for the water heater is voided. This means the final inspection and approval were notcompleted by the building department. Recommend obtaining a "final" status to ensure the waterheater complies with applicable plumbing codes.

Definition
The ductwork installed to bring fresh outside air to the furnace and/or hot water heater. Normally, two separate supplies of air are brought in: one high and one low.
Page 87: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 86 of 96

Water heater failed final inspection13. ELECTRICALObservations:

N/A.

Page 88: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 87 of 96

PLUMBING - OTHER 1. WATER PRESSUREObservations:

Water pressure, typically set between 50 - 70 psi, is elevated at 80 psi. Pressure at or above 80 psican cause damage to water supply piping, valves, and fixtures. Recommend licensed plumber orqualified contractor evaluate and repair as needed. This will most likely entail adjusting or replacingthe water pressure regulator.

Water pressure too high (80 psi)2. WATER PRESSURE REGULATORObservations:

There are no adverse conditions.

3. WATER MAINMaterials:

The water main and shutoff are located in the utility room.Observations:

There are no adverse conditions.

Page 89: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 88 of 96

4. WATER SUPPLY LINESMaterials:

The home is equipped with polybutylene water supply lines.Observations:

The home is equipped with polybutylene water lines. Polybutylene is a form of plastic resin thatwas used extensively in the manufacture of water supply piping from 1978 until 1995. Due to thelow cost of the material and ease of installation, polybutylene piping systems were viewed as "thepipe of the future" and were used as a substitute for traditional copper piping. However,polybutylene pipes have a history of failure and have been the focus of a class action lawsuit.Typically, the pipes can fail in two ways. First, the pipes can fail at the connectors. Second, it isbelieved that oxidants in the public water supplies such as chlorine and fluoride react with thepolybutylene pipes causing them to scale, flake, and become brittle. The resulting micro-fracturescan reduce the basic structural integrity of the system. Thus, the system can become weak and failwithout warning years after it was installed. Recommend licensed plumber or qualified contractorevaluate and replace as needed.

Polybutylene water lines Polybutylene water lines5. DRAIN LINESMaterials:

The home is equipped with PVC drain lines secured with metal strapping.Observations:

There are no adverse conditions.

6. SANITARY PUMPMaterials:

N/A.

Definition
Polyvinyl chloride, which is used in the manufacture of white plastic pipe typically used for water supply lines.
Page 90: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 89 of 96

7. SEWER LINEMaterials:

The sewer line extending from the home to the public sewer system is not visible during the homeinspection. Accordingly, the sewer line is outside the scope of the inspection. Problems with thesewer line (e.g. damage, deterioration, blockage, improper slope, etc.) may not be detected bysimply running water through the plumbing system. Therefore, we strongly encourage all clients tohave a licensed plumber or qualified contractor scope the sewer line to determine whether anyadverse conditions exist.

8. WATER SUPPLY (WELL SYSTEM)Observations:

N/A.

Page 91: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 90 of 96

HEATING - FURNACE 1. LOCATIONMaterials:

The furnace is located in the utility room.

2. AGEObservations:

The furnace is 18 years old. The average life expectancy for a gas fired forced air furnace is 15 -25 years. Although functioning at the time of the inspection, the furnace could be nearing the endof its useful life.

3. GAS LINEObservations:

There are no adverse conditions.

4. FLUEObservations:

There are no adverse conditions.

5. FURNACEObservations:

The furnace is very dirty and does not appear to have been cleaned and serviced in number ofyears. Recommend licensed HVAC technician clean and service.

6. COMBUSTION AIRObservations:

The utility room is not equipped with a source for combustion air. Insufficient combustion air cancause back venting in the flue pipe, allowing combustible byproducts (including carbon monoxide)to enter the home. Potential safety hazard. Recommend licensed contractor evaluate and ventilatethe utility room as needed. This will most likely entail installing a louvered door and/or wall vents.

7. PERMITObservations:

The furnace is not permitted. Typically, we would recommend obtaining a retroactive permit toensure the furnace complies with applicable HVAC codes. However, this may not be reasonable orfeasible given the amount of time that has lapsed (18 years) since the furnace was installed.Recommend consulting the building department.

Page 92: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 91 of 96

COOLING - AIR CONDITIONER 1. COOLING SYSTEMObservations:

The air conditioner is 8 years old. The average life expectancy for a central air conditioning systemis 10 – 15 years. Although functioning at the time of the inspection, the cooling system could benearing the end of its useful life.

2. CONDENSING UNITObservations:

The condenser fins are dirty. The purpose of the condenser fins is to dissipate the heat from thecoolant that flows through the coil. Even a modest amount of dirt and debris can significantlyreduce the efficiency of the cooling system. Recommend licensed HVAC technician clean andservice.

3. REFRIGERANT LINESObservations:

The insulation on the refrigerant lines is missing. Inadequate or missing insulation can cause therefrigerant lines to gain heat from ambient air. This causes the compressor to operate lessefficiently. Recommend installing as needed.

Insulation on refrigerant lines missing Insulation on refrigerant lines missing4. EVAPORATOR COILS

5. CONDENSATE DRAIN PAN

6. CONDENSATE DRAIN LINE

7. PERMIT

Page 93: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 92 of 96

Page 94: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 93 of 96

HEATING/COOLING - OTHER 1. THERMOSTAT(S)Observations:

There are no adverse conditions.

2. DUCTWORKObservations:

There are no adverse conditions.

3. HUMIDIFIERObservations:

N/A.

4. CONDENSATE PUMPObservations:

N/A.

Page 95: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 94 of 96

ELECTRICAL This report describes the amperage and voltage rating of the service, the location of the maindisconnect and any sub panel(s), the presence of solid conductor aluminum branch circuit wiring, thepresence or absence of smoke detectors and wiring methods. Inspectors are required to inspect theviewable portions of the service drop from the utility to the house, the service entrance conductors,cables and raceways, the service equipment and main disconnects, the service grounding, theinterior components of the service panels and sub panels, the conductors, the over-currentprotection devices (fuses or breakers), ground fault circuit interrupters and a representative numberof installed lighting fixtures, switches and receptacles. All issues or concerns listed in this Electricalsection should be construed as current and a potential personal safety or fire hazard. Repairs shouldbe a priority, and should be made by a qualified, licensedelectrician.

1. MAIN PANELLocation:• The main panel is located in the garage.Location: The main panel service size is 200 amps.Observations:• There are “knock outs” missing in the panel cover. Potential safety hazard. This is where circuitsare no longer used and the breakers have been removed but the openings in the panel have notbeen covered. All openings in the panel cover should be sealed as there is still power flowing tothe area and touching it could result in a severe shock. Recommend installing covers.

Knockouts missing in panel cover2. SUB PANEL(S)Observations:

N/A.

3. BRANCH CIRCUIT WIRINGMaterials:

The branch circuit wiring is comprised of Romex.Observations:

There are no adverse conditions.

Page 96: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 95 of 96

4. PERMIT(S)Observations:

N/A.

5. FUSE BOXMaterials:

N/A.

Page 97: Inspector: Mark Baxley, Brick and Mortar Home Inspections ... · Page 34 Item: 6 DECK There is moisture damage visible on the deck joists. ... A special device that is intended for

Brick and Mortar Home Inspections, Inc. 1234 Sample Drive

Page 96 of 96

GlossaryGlossary

Term DefinitionCombustion Air The ductwork installed to bring fresh outside air to the furnace

and/or hot water heater. Normally, two separate supplies of airare brought in: one high and one low.

GFCI A special device that is intended for the protection of personnelby de-energizing a circuit, capable of opening the circuit wheneven a small amount of current is flowing through the groundingsystem.

PVC Polyvinyl chloride, which is used in the manufacture of whiteplastic pipe typically used for water supply lines.

Valley The internal angle formed by the junction of two sloping sides ofa roof.