Quick Install Guide 913-2106-01 Rev A 11/14 I2BP-4x10 iBypass TM 40-10

Upload: others

Post on 12-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

-Quick Install Guide

913-2106-01 Rev A 11/14

I2BP-4x10

iBypassTM 40-10

Page 2: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

2

PLEASE READ THESE LEGAL NOTICES CAREFULLY.

Trademarks and Copyrights

Net Optics, and iBypassTM are registered trademarks of Net Optics, Inc. By using the iBypassTM 40-10 Switch, you agree to the terms and conditions of usage set forth by Ixia.

Copyright ©2006-2014 by Net Optics, Inc. with modifications Copyright © 2014 Ixia. All rights reserved.

This publication may not be copied, in whole or in part, without Ixia’s consent. RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the U.S. Government is subject to the restrictions set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 and FAR 52.227-19.Ixia, the Ixia logo, and all Ixia brand names and product names in this document are either trademarks or registered trademarks of Ixia in the United States and/or other countries. All other trademarks belong to their respective owners.The information herein is furnished for informational use only, is subject to change by Ixia without notice, and should not be construed as a commitment by Ixia. Ixia assumes no responsibility or liability for any errors or inaccuracies contained in this publication.

This product is covered under the Ixia Limited Warranty and Technical Support Agreement. You can find this Agreement by going to the following link -- http://www.ixiacom.com/support/warranty/. Click on the Limited Warranty and Technical Support Agreement link to view the document.

Page 3: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

3

ContentsiBypass 40-10 Switch Content 4iBypass 40-10 Switch Overview 5Step 1 6

Rack Mount iBypass 40-10 Switch 6Step 2 7

Connect Power 7Step 3 8

Connect Options 8Step 4 12

Configure the IP 12Assign IP in Web UI 14

Step 5 16Connect to Network 16

Step 6 17Connect to Monitoring Tools 17Multiple Segments 18

Step 7 19Check for Recent Updates 19Support 20

Page 4: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

4

iBypass 40-10 Switch Content This guide provides the initial steps to install and configure the iBypassTM 40-10 Switch.

Carefully unpack the contents and verify you have the following components:

• iBypass 40-10 Switch

• 3-meter RJ45, CAT 5e 4-pair (purple)

• RJ45 to DB9 Console Port to PC cable

• 4 Breakout cables, MTP-4LC, OM4

• Long Ear Extender and Short Ear Extender and eight Phillips screws (10-32 x 5/8) for rack mounting

• Two External Power Supplies (12VDC, 9A, 108W)

• iBypass 40-10 Switch Quick Install Guide (this document)

• iBypass 40-10 Switch User Guide (on CD)

• End User Agreement, Registration Card and Extended Warranty (if purchased)

QSFP+ transceivers are ordered and shipped separately.

Check the packing slip against parts received. If any component is missing or damaged, contact our Order Management department via email at [email protected] or if this is a Demo unit, contact [email protected].

Page 5: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

5

iBypass 40-10 Switch Overview

Figure 1 - Front View

• Console Port (RJ45) and Management Port (RJ45)

• 2 x 40G Monitor Ports (uses QSFP+ transceivers) 2 x 40G Network Ports (MTP Connectors)

• Hot swappable fans and replaceable power module

Figure 2 - Rear View

2x16 Character DisplayNetwork

PortsMonitorPorts

Bypass, Tap, PowerLEDs

Activity & AlarmLEDs

ManagementPort

ConsolePort

Page 6: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

6

Step 1Rack Mount iBypass 40-10 Switch

The switch is designed to occupy one rack unit height of a standard 19” rack. Do the following to install the iBypass 40-10 Switch into an equipment rack:

1. Remove the Ear Extenders and screws from the shipping bag.

2. Attach the Long Ear Extender to the switch if you are only mounting one switch or attach the Short Ear Extender between two switches if you are mounting two switches. See Figure 3.

3. Slide the switches in place in the rack.

4. Fasten the switches in place at the front panel ears using the included Phillips screws.

Figure 3 - Attach Ear Extenders for Rack Mount

Long Ear Extenderfor one switch

Short Ear Extenderbinds two switches

Page 7: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

7

Step 2Connect Power

Before connecting power, ground the switch to the rack by connecting a 14AWG minimum ground wired with a #8 ring lug from the switch to a suitable ground connection on the rack.

Do the following to connect and apply power to the iBypass 40-10 Switch:

1. Plug one of the supplied power cords to a power connector located at the rear of the chassis. Plug the other end to a power source. See Figure 4.

2. For redundancy, plug the other power cord to the iBypass 40-10. Plug the other end to a source independent from the first power source.

The Power LEDs on the front illuminate.

Figure 4 - Power Connections

Page 8: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

8

Step 3Connect Options

Switch Default Settings

The iBypass 40-10 Switch ships with the following default system settings:

IP Address: 10.60.4.180 Monitor and Port Thresholds: 80%

Netmask: 255.0.0.0 Username: admin

Gateway: 10.0.0.1 Password: admin

You have two ways of logging into the iBypass 40-10 Switch.

Connect Option 1 - Connect PC to Management Port

1. Establish a PC you want to use to connect to the switch. Make sure it’s IP address is on the same subnet as the iBypass switch. The default address settings of the switch are shown above.

2. Connect one end of the included Cat 5e cable to the PC’s Ethernet port and connect the other end to the iBypass Management port. See Figure 5.

3. Open a terminal window on the PC and ping 10.60.4.180 to confirm the connection.

4. After you have confirmed that you have a connection, you can log in via SSH at the terminal prompt, or enter the default address into the browser URL. Go to the Assign IP in Web UI section if you want to log in through the Web UI. Go to the next step if you want to log in to the CLI.

Page 9: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

9

5. At the terminal window prompt, type ssh [email protected]. Enter password admin. The prompt appears.

6. At the prompt, enter admin for the user and admin for the password.

7. Change the password for the admin account by entering the following command at the prompt:

modify user password admin <new_passwd> <re-enter_passwd>

where <new_passwd> is the new password for the admin account and <re-enter_passwd> is new password entered again.

8. Go to Configure the IP section and follow the instructions to set a new IP address.

PC on the same subnet as iBypass 4x10G switch

Connect Cat 5e cable from Management port to

PC Ethernet

Figure 5 - PC to Management PortFor more information about using the iBypass 40-10 Switch CLI, enter help to display command information or see the iBypass 40-10 Switch User Guide for more details.

Page 10: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

10

Step 3 (cont.)

Option 2 - Connect PC to the Console Port

1. Connect a PC running terminal emulation software to the iBypass 40-10 Switch Console port with the supplied RJ45-DB9 console cable. See Figure 6.

2. Launch the terminal emulation software, such as HyperTerminal or minicom, and set the communication parameters to:

115200 baud 8 data bits no flow control no parity 1 stop bit

3. At the prompt, enter admin for the user and admin for the password.

4. Change the password for the admin account by entering the following command at the prompt:

modify user password admin <new_passwd> <re-enter_passwd>

where <new_passwd> is the new password for the admin account and

<re-enter_passwd> is the new password entered again.

5. Go to Configure the IP section and follow the instructions to set a new IP address.

For more information about using the iBypass 40-10 Switch CLI, enter help to display command information or see the iBypass 40-10 Switch User Guide for more details.

Page 11: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

11

Computer with terminal emulation software

RJ45 to DB9 console cable

Figure 6 - PC to Console Port

Page 12: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

12

Step 4Configure the IP

The iBypass 40-10 Switch ships with a default address. You can decide to use the default address, assign a static IPv4 IP address or use DHCP to assign an address.

To configure the system with a static IPv4 address, do the following:

1. At the CLI prompt, type the following to set the address mode to static:

set network mode static

2. Type the following to set the IPv4 address:

set network ipaddress <d.d.d.d> where <d.d.d.d> is the IPv4 address.

3. Type the following to set the network mask:

set network netmask <m.m.m.m> where <m.m.m.m> is the netmask.

4. Type the following to set the gateway:

set network gateway <g.g.g.g> where <g.g.g.g> is the gateway address.

Type reboot, to reboot the system. This is required for the new address to take effect.

Page 13: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

13

To configure the system to use a DHCP address, do the following:

1. At the CLI prompt, type the following to set the address mode:

set network mode dhcp

2. At the next prompt, type the following to reboot the device:

reboot

3. After reboot, log into the iBypass via the PC connected to the Console port.

4. At the CLI prompt, enter show network. The screen will display the address that was assigned to the switch.

After setting the IP address, connect the Management port to the network, if you have not already done so, in order to access the device remotely over SSH or the Web UI.

Page 14: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

14

Assign IP in Web UI

If you want to change the IP address through the Web UI, do the following:

1. Open a browser on a PC connected to the iBypass switch and on the same subnet, and enter the default IP address in the URL, https://10.60.4.180.

2. At the iBypass log in banner page, enter Username admin and Password admin. The Home page displays. See Figure 7.

3. Click on the Admin tab. Under the Users List, enter a new password for the admin user. Re-enter the new password and click Update. Remember the new password. You must use the new password for subsequent log ins.

4. Click on the Configuration tab. The Configuration page displays. See Figure 8.

5. The IP Version field displays IPv4. Do not use IPv6 at this time.

6. In the DHCP field, select Static or Dhcp.

7. If you select Static, enter the IP address, netmask, and default gateway.

8. If you select Dhcp, your DHCP server will assign an IP address to the iBypass switch.

9. Click the Apply button for the changes to take effect.

10. After the iBypass has rebooted, enter the new IP address at the URL. The iBypass home page displays.

Page 15: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

15

Figure 8 - Configure IP in Web UI

Figure 7 - Home Page

Page 16: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

16

Step 5Connect to Network

Each iBypass Network port operates with one MTP-4LC breakout cable.

Figure 9 - Cables to the Network

1. Plug into each Network port, an MTP-4LC breakout cable.

2. Connect the LC connectors to the network devices.

Each cable pair functions as Network port A

Seg 1 port A

Seg 2 port A

Seg 4 port A

Seg 3 port A

Seg 1 port B

Seg 2 port B

Seg 4 port B

Seg 3 port B

t r t r t r t r t r t r t r t r

s4s3s2s1 s4s3s2s1

Each cable pair functions as Network port B

Page 17: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

17

Step 6Connect to Monitoring Tools

Each iBypass Monitor port requires a QSFP+ and one MTP-4LC breakout cable.

Figure 10 - Cables to the Monitoring Tools

1. Plug a QSFP+ into the upper and lower Monitor ports 1 and 2.

2. Plug an MTP-4LC breakout cable into each QSFP+.

3. Connect the LC connectors to the monitoring tools.

Each cable pair functions as Monitor port 1

t r t r t r t r

Seg 1 port 1

Seg 2 port 1

Seg 4 port 1

Seg 3 port 1

t r t r t r t r

Seg 1 port 2

Seg 2 port 2

Seg 4 port 2

Seg 3 port 2

Each cable pair functions as Monitor port 2

s4s3s2s1s4s3s2s1

Page 18: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

18

Multiple Segments After you plug a breakout cable into each Monitor port and each Network port, you have four 10G segments (SEG 1, 2, 3 and 4).

t r t r t r t rt r t r t r t r t r t r t r t r t r t r t r t r

s4s3s2s1 s4s3s2s1s4s3s2s1s4s3s2s1

Monitor 2Monitor 1 Network BNetwork A

Page 19: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

19

Step 7Check for Recent Updates

We recommend that you check the Customer Portal for software or informational updates. There might be recent updates that may affect the operation of your device.

1. Go to www.netoptics.com and click on the Customer Portal link.

2. If you have not already done so, create a new account. Note, it might take up to 24 hours to get a password.

3. Sign in to your account with the password.

4. Go to Premium Software Updates > iBypass 40-10 link.

5. Review the Release Notes.

6. If a software update is available and installation is desired, follow the instructions on the Release Notes.

Page 20: iBypass 40-10 - Ixia · 2015. 3. 16. · • Two External Power Supplies (12VDC, 9A, 108W) • iBypass 40-10 Switch Quick Install Guide (this document) • iBypass 40-10 Switch User

20

Support

If you have questions while your product is under warranty or you are enrolled in a support plan, please contact one of Ixia’s Technical Assistance Centers (TACs) by phone or e-mail.

US: +1 818 595 2599 E-mail: [email protected] EMEA: +40 21 3015699 E-mail: [email protected] India: +91-80-49396410 E-mail: [email protected] Japan: +81-3-5326-1980 E-mail: [email protected] APAC: +65-6332-0126 E-mail: [email protected] China: +400-898-0598 E-mail: [email protected] Taiwan/Hong Kong: +86-10-5732-3932 E-mail: [email protected]

or visit www.ixiacom.com/support.