hydraulic fracturing design
TRANSCRIPT
Proppant BradySand 40/70Fluid Hybor (aka HG50G2K)
Slurry Rate Fracture Efficiency
bpm % ft15 10 9.55 46.9 2460
30 10 9.34 55.2 2460
50 10 9.29 66.7 2460
70 10 9.36 72.1 2460
80 10 10.17 73.8 2460
90 10 10.05 75.3 2460
100 10 10.32 76.5 2460
150 10 9.78 78.8 2460180 10 11.38 81.7 2460185 10 11.12 82 2460190 10 11.91 85.1 1620200 10 13.01 86.7 1440800 10 44.58 95.9 420
Proppant BradySand Sizes ComparrisonFluid Hybor (aka HG50G2K)
Proppant size Slurry Rate Fracture Efficiency
bpm %
40/70 185 10 11.72 71.520/40 185 10 11.48 81.630/50 185 10 11.52 82.6
Proppant BradySand Sizes ComparrisonFluid 2% KCl
Proppant size Slurry Rate Fracture Efficiency
bpm %
40/70 600 10 10.35 89.120/40 600 10 9.77 88.830/50 600 10 11.93 89.4
Proppant BradySand Sizes ComparrisonFluid Slickwater
Designed FcD FcD obtained Designed xF
Designed FcD FcD obtained
Designed FcD FcD obtained
Proppant size Slurry Rate Fracture Efficiency
bpm %
40/70 600 10 10.79 89.120/40 600 10 9.86 89.130/50 600 10 9.04 89.2
Fluid Propped length Time (min,sec) Time (min)Hybor 2452.6 135 min, 5 sec 135.082% KCl 2546 42min,11 sec 42.18Slickwater 2538.7 42 min, 9 sec 42.15
Designed FcD FcD obtained
Hybor
2% KCl
Slickwater
2400 2420 2440 2460 2480 2500 2520 2540 2560
Propped Length (ft)Fl
uid
Type
Hybor
2% KCl
Slickwater
0 20 40 60 80 100 120 140 160
Treatment Time (min)
Flui
d Ty
pe
Hybor
2% KCl
Slickwater
70 71 72 73 74 75 76 77 78
Average Fracture Conductivity (md·ft)
Flui
d Ty
pe
ProppantFluid
Propped Length Average Prop Conc Slurry Rate
ft bpm2416.5 0.4 15
2459.1 0.4 30
2467.4 0.5 50
2473.6 0.5 70
2484.8 0.5 80
2489.9 0.5 90
2516.8 0.5 100
2683.6 0.5 1502429.4 0.6 1802452.6 0.5 1851633.7 0.4 1901326.5 0.3 200382.8 0.2 250
300350400450
Propped Length Average Prop Conc 500
ft ft 600700
2460 2408.1 0.52460 2537.2 0.22460 2354 0.3
Propped Length Average Prop Conc
ft ft
2460 2546 0.52460 2663 0.22460 2430.7 0.3
lb/ft2
Designed xF
lb/ft2
Designed xF
lb/ft2
Propped Length Average Prop Conc
ft ft
2460 2538.7 0.52460 2485.4 0.22460 2576.4 0.3
Fracture efficiency Conductivity82 77.04
89.1 72.8289.1 75.86
Designed xF
lb/ft2
Hybor
2% KCl
Slickwater
2400 2420 2440 2460 2480 2500 2520 2540 2560
Propped Length (ft)
Flui
d Ty
pe
Hybor
2% KCl
Slickwater
0 20 40 60 80 100 120 140 160
Treatment Time (min)
Flui
d Ty
pe
Hybor
2% KCl
Slickwater
70 71 72 73 74 75 76 77 78
Average Fracture Conductivity (md·ft)
Flui
d Ty
pe
BradySand 40/702% KCL
Fracture Efficiency Propped Length
% ft ft10 9.85 46.2 2460 2374.2
10 9.76 56.1 2460 2353.6
10 10.12 64.4 2460 2376.7
10 9.4 70.5 2460 2324.5
10 9.13 71.5 2460 2483.2
10 9.06 73.8 2460 2355
10 9.42 75.1 2460 2410.6
10 10.41 79.2 2460 2506.610 10.69 80.9 2460 2540.410 9.41 81.4 2460 2450.510 10.73 81.4 2460 256010 9.22 81.8 2460 2611.510 10.61 82.9 2460 2629.710 10.32 84.7 2460 2478.910 10.73 85.1 2460 2695.410 9.28 86.5 2460 2569.710 10.02 87.7 2460 2375.1
10 10.76 88 2460 2525.5
10 10.35 89.1 2460 254610 10.49 90.5 2100 2220.2
Designed FcD FcD obtained Designed xF
0 100 200 300 400 500 600 700 8000
102030405060708090
100
Hybor 2% KCl Slickwater
Slurry Rate (bpm)
Frac
ture
Effi
cienc
y (%
)
0 50 100 150 200 2500
500
1000
1500
2000
2500
3000
Hybor
Slurry Rate (bpm)
Prop
ped
Leng
th (ft
)
0 100 200 300 400 500 600 700 8000
500
1000
1500
2000
2500
3000
2% KCl
Slurry Rate (bpm)
Prop
ped
Leng
th (ft
)
Hybor
2% KCl
Slickwater
78 80 82 84 86 88 90
Fracture Efficiency (%))
Flui
d Ty
pe
Hybor
2% KCl
Slickwater
78 80 82 84 86 88 90
Fracture Efficiency (%))
Flui
d Ty
pe
Proppant BradySand 40/70Fluid Slickwater
Average Prop Conc Slurry Rate
bpm0.4 15 10 10.09
0.4 30 10 9.43
0.4 50 10 9.72
0.4 70 10 9.28
0.5 80 10 9.35
0.4 90 10 9.92
0.4 100 10 10.04
0.5 150 10 9.980.5 180 10 10.250.4 185 10 10.430.5 190 10 10.310.5 200 10 10.580.5 250 10 10.180.5 300 10 10.710.5 350 10 10.190.4 400 10 9.310.4 450 10 11.05
0.5 500 10 10.04
0.5 600 10 10.790.4 650 10 11.23
800 10 12.07
Designed FcD FcD obtained
lb/ft2
0 100 200 300 400 500 600 700 8000
102030405060708090
100
Hybor 2% KCl Slickwater
Slurry Rate (bpm)
Frac
ture
Effi
cienc
y (%
)
0 100 200 300 400 500 600 700 8000
500
1000
1500
2000
2500
3000
Hybor 2% KCl Slickwater
Slurry Rate (bpm)
Prop
ped
Leng
th (ft
)
0 100 200 300 400 500 600 700 8000
500
1000
1500
2000
2500
3000
Hybor 2% KCl Slickwater
Slurry Rate (bpm)
Prop
ped
Leng
th (ft
)0 50 100 150 200 250
0
500
1000
1500
2000
2500
3000
Hybor
Slurry Rate (bpm)
Prop
ped
Leng
th (ft
)
0 100 200 300 400 500 600 700 8000
500
1000
1500
2000
2500
3000
2% KCl
Slurry Rate (bpm)
Prop
ped
Leng
th (ft
)
0 100 200 300 400 500 600 700 800 9000
500
1000
1500
2000
2500
3000
Slickwater
Slurry Rate (bpm)
Prop
ped
Leng
th (ft
)
Hybor
2% KCl
Slickwater
78 80 82 84 86 88 90
Fracture Efficiency (%))
Flui
d Ty
pe
Hybor
2% KCl
Slickwater
78 80 82 84 86 88 90
Fracture Efficiency (%))
Flui
d Ty
pe
Fracture Efficiency Propped Length Average Prop Conc
% ft ft46.1 2460 2388.3 0.4
55 2460 2425.9 0.4
64.5 2460 2376.4 0.4
70.5 2460 2262.9 0.4
72.3 2460 2349.8 0.4
73.4 2460 2433.9 0.5
74.6 2460 2451.2 0.5
79.3 2460 2507.3 0.580.9 2460 2540.5 0.581.1 2460 2541.7 0.581.4 2460 2558.6 0.581.8 2460 2568.2 0.582.9 2460 2629.9 0.584 2460 2673.8 0.6
85.7 2460 2519.8 0.587.1 2460 2344.1 0.487.5 2460 2484.5 0.5
88.4 2460 2329.2 0.4
89.1 2460 2538.7 0.590.2 2340 2209.2 0.591.8 1860 1906.6 0.4
Designed xF
lb/ft2
0 100 200 300 400 500 600 700 8000
500
1000
1500
2000
2500
3000
Hybor 2% KCl Slickwater
Slurry Rate (bpm)
Prop
ped
Leng
th (ft
)
0 100 200 300 400 500 600 700 8000
500
1000
1500
2000
2500
3000
Hybor 2% KCl Slickwater
Slurry Rate (bpm)
Prop
ped
Leng
th (ft
)
0 100 200 300 400 500 600 700 800 9000
500
1000
1500
2000
2500
3000
Slickwater
Slurry Rate (bpm)
Prop
ped
Leng
th (ft
)