hvac2 coils
TRANSCRIPT
-
8/8/2019 Hvac2 Coils
1/12
1034
COILS
28B SERIES
SEPARATE SALEPLATE FIN WATER COILS
CARRIER COILS FOR USE WITH OUR 39 SERIES AIRHANDLING EQUIPMENT, COMPETITORS EQUIPMENT,AND OTHER APPLICATIONS
Features:
Plate fin design with 1/2-in. or 5/8-in.
diameter copper tubes
Chilled or hot water coils in lengths
from 24 in. to 144 in. (in one-inch
increments)
Chilled and hot water coils available in
heights from 15 in. to 55 in. (in2-1/2-inch increments)
Hot water booster coil lengths range
from 12 in. to 43 in. with heights from
5 in. to 15 in.
Each coil is computer selected to
meet your specific job requirements
using a computer program approved
by ARI Standard 410
All 28B coils are available in fin
spacings of 8, 11, or 14 fins per in.
Cooling coils are available in 2, 4, 6,
or 8 rows. Heating coils are available
in 1, 2, or 4 rows.
Carriers 28B Series water coils offer a wide range of sizes and are
manufactured in accordance with ARI Standard 410. Top qualitychilled water cooling coils and hot water heating coils are offered
with options that provide a custom fit for your applications.
P914
Nu Fin Coils B&W
FOR MORE INFORMATION ABOUT COILS, CONTACT US AT:
PHONE - 1-800-225-COIL or (1-800-225-2645)
FAX - 1-315-432-7966
E-MAIL - [email protected]
-
8/8/2019 Hvac2 Coils
2/12
1035
COILS
MODEL NUMBER NOMENCLATURE - 28BC
28B C A 4 32 F A A 060 A R
28B - NU-FIN SEPARATESALE COIL
COATINGA = No CoatingB = Epoxy (E-coat) Coating
FIN MATERIAL, FPI AND CASING MATERIALA = AL 8 GALV.B = AL 11 GALV.C = AL 14 GALV.D = AL 8 ST. STL.E = AL 11 ST. STL.F = AL 14 ST. STL.G = CU 8 ST. STL.H = CU 11 ST. STL.J = CU 14 ST. STL.
TUBES IN FACE12-44 Tubes in 2-Tube Increments
CIRCUITING*Q - Quarter
H - HalfF - FullD - Double
HAND**R = Right HandL = Left Hand
NOZZLE ANDHEADER STYLEA = MPT - STDB = MPT - Non FerrousC = Victaulic
DBTS (DISTANCE BETWEENTUBE SHEETS)In inches from 24 to 144 in 1 inchincrements.For Example,024 = 24 inches
121 = 121 inchesROWS4 - 46 - 68 - 80 - 10
TUBE WALL, HAIRPIN(1/2OD COPPER TUBE)A = 0.016 in., STD. HAIRPINB = 0.025 in., HEAVY WALL
COIL MODELC= Cooling Coil -1/2Tubes
* Quarter circuit available for 4 row coils with TIF = 12, 16, 20, 24,28, 32, 36, 40, 44 only. Half, full or double circuit available withany 4, 6, or 8 row.
CIRCUIT NOMINAL PIPE SIZE (in.)
Q 1-1/2
F 2-1/2
H 2-1/2
D 3
**Hand is determined by the location of coil connections whenviewed while facing the coil air inlet.
NOTE: Example shown is for a 4-row cooling coil, not coated; 32tubes in face; a full circuit, with 8 aluminum fins per inch and galva-nized casing; and 1/2-in. O.D. copper tubes with 0.016-in. wall thick-ness. The coil is 60 in. long between tube sheets and hasright-hand, 2-1/2-in. MPT standard steel headers.
Nu Fin Coils B&W
-
8/8/2019 Hvac2 Coils
3/12
1036
COILS
MODEL NUMBER NOMENCLATURE - 28BH28B H A 2 24 F A A 120 A R
28B - NU-FIN SEPARATESALE COIL
COATINGA = No CoatingB = Epoxy (E-coat) Coating
FIN MATERIAL, FPI AND CASING MATERIALA = AL 8 GALV.B = AL 11 GALV.C = AL 14 GALV.D = AL 8 ST. STL.E = AL 11 ST. STL.F = AL 14 ST. STL.G = CU 8 ST. STL.H = CU 11 ST. STL.J = CU 14 ST. STL.
TUBES IN FACE12-44 Tubes in 2-Tube Increments
CIRCUITING*
H - HalfF - Full
HAND**R = Right Hand
L = Left Hand
NOZZLE ANDHEADER STYLEA = MPT - STDB = MPT - Non FerrousC = Victaulic
DBTS (DISTANCE BETWEENTUBE SHEETS)In inches from 24 to 144 in 1 inchincrements.For Example,024 = 24 inches
121 = 121 inches
ROWS1, 2, 4
TUBE WALL, HAIRPIN(1/2OD COPPER TUBE)A = 0.016 in., STD. HAIRPINB = 0.025 in., HEAVY WALL
COIL MODELH = Heating Coils -1/2Tubes
* Half circuit available for 1-row or 2-row coils; full circuit availablefor 2-row only.
CIRCUIT NOMINAL PIPE SIZE (in.)
H 1-1/2
F 2-1/2
**Hand is determined by the location of coil connections whenviewed while facing the coil air inlet.
NOTE: Example shown is for a 2-row heating coil, not coated;24 tubes in face; a full circuit, with 8 aluminum fins per inch and gal-
vanized casing; and 1/2-in. O.D. copper tubes with 0.016-in. wallthickness. The coil is 120 in. long between tube sheets and hasright-hand, 2-1/2-in. MPT standard steel headers. Nu Fin Coils B&W
-
8/8/2019 Hvac2 Coils
4/12
1037
COILS
MODEL NUMBER NOMENCLATURE - 28BB
28B B A 2 12 T A A 024 1 R
28B - NU-FIN SEPARATESALE COIL
CASING/COATINGA = Flanged/No CoatingB = Flanged/Epoxy (E-coat)C = Drive Clip/No CoatingD = Drive Clip/Epoxy (E-coat)
FIN MATERIAL, FPI AND CASING MATERIALA = AL 8 GALV.B = AL 11 GALV.C = AL 14 GALV.D = AL 8 ST. STL.E = AL 11 ST. STL.F = AL 14 ST. STL.G = CU 8 ST. STL.H = CU 11 ST. STL.J = CU 14 ST. STL.
TUBES IN FACE4-18 Tubes in 2-Tube Increments
CIRCUITING*S - Single (Full)T - Two (for 2-row coils only)
HAND R = Right HandL = Left Hand
NOZZLE STYLE1 = 1/2OD Copper Std.2 = MPT Fitting
DBTS (DISTANCE BETWEENTUBE SHEETS)In inches from 12 to 42 in 3-inch incre-ments (up to 30 inches); and from 30 to 42in 6-inch increments.For Example,
012 = 12 inches036 = 36 inches
ROWS1, 2
TUBE WALL, HAIRPIN TYPE(1/2OD COPPER TUBE)A = 0.016 in., STD. HAIRPINB = 0.025 in., STD. HAIRPIN
COIL MODELB = Booster
* Two circuits available with 2-row coils only.
Hand is determined by the location of coil connections whenviewed while facing the coil air inlet.
NOTE: Example shown is for a 2-row booster coil with flanged cas-ing; 12 tubes in face, 2 circuits, with 8 aluminum fins per in. and gal-vanized casings; and 1/2-in. OD copper tubes with 0.016-in. wallthickness. The coil is 24 in. long between tube sheets, withright-hand 1/2 in. OD copper stubout for field-supplied sweatconnection.
Nu Fin Coils B&W
-
8/8/2019 Hvac2 Coils
5/12
1038
COILS
MODEL NUMBER NOMENCLATURE - 28BD
28B D A 4 32 F A B 060 A R
28B - NU-FIN SEPARATESALE COIL
COATINGA = No CoatingB = Epoxy (E-coat) Coating
FIN MATERIAL, FPI AND CASING MATERIALA = AL 8 GALV.B = AL 12 GALV.C = AL 14 GALV.D = AL 8 ST. STL.E = AL 12 ST. STL.F = AL 14 ST. STL.G = CU 8 ST. STL.H = CU 11 ST. STL.J = CU 14 ST. STL.
TUBES IN FACE12-36 Tubes in 2-Tube Increments
CIRCUITINGH- HalfF - FullD - Double
HAND **R = Right HandL = Left Hand
NOZZLE AND HEADERSTYLEA = MPT - STDB = MPT - Non FerrousC = Victaulic
DBTS (DISTANCE BETWEENTUBE SHEETS)In inches from 24 to 144 in 1 inch incre-ments.
For Example,024 = 24 inches121 = 121 inches
ROWS4 - 46 - 68 - 8
TUBE WALL, HAIRPIN(5/8OD COPPER TUBE)B= 0.020 in., STD. HAIRPINC= 0.035 in., HEAVY WALL
COIL MODELD= Cooling Coil -5/8Tubes
**Hand is determined by the location of coil connections whenviewed while facing the coil air inlet.
NOTE: Example shown is for a 4-row cooling coil, not coated;32 tubes in face; a full circuit, with 8 aluminum fins per inch and gal-vanized casing; and 5/8-in. O.D. copper tubes with 0.020-in. Wallthickness. The coil is 60 in. long between tube sheets and hasright-hand, 2-1/2-in. MPT optional steel headers.
CIRCUIT NOMINAL PIPE SIZE (IN.)
F 2-1/2
H 2-1/2
D 3
Nu Fin Coils B&W
-
8/8/2019 Hvac2 Coils
6/12
1039
COILS
MODEL NUMBER NOMENCLATURE - 28BF
28B F A 2 24 F A B 120 A R
28B - NU-FIN SEPARATESALE COIL
COATINGA = No CoatingB = Epoxy (E-coat) Coating
FIN MATERIAL, FPI AND CASING MATERIALA = AL 8 GALV.B = AL 12 GALV.C = AL 14 GALV.D = AL 8 ST. STL.E = AL 12 ST. STL.F = AL 14 ST. STL.G = CU 8 ST. STL.H = CU 12 ST. STL.J = CU 14 ST. STL.
TUBES IN FACE12-36 Tubes in 2-Tube Increments
CIRCUITINGH- HalfF - Full
HAND**R = Right HandL = Left Hand
NOZZLE ANDHEADER STYLEA = MPT - Steel OptionalB = MPT - Non Ferrous - STDC = Victaulic
DBTS (DISTANCE BETWEENTUBE SHEETS)In inches from 24 to 144 in 1 inchincrements.For Example,
024 = 24 inches121 = 121 inches
ROWS1, 2
TUBE WALL, HAIRPIN(5/8OD COPPER TUBE)B= 0.020 in., STD. HAIRPINC= 0.035 in., HEAVY WALL
COIL MODELH= Heating Coils -5/8Tubes
* Half circuit available for 1-row or 2-row coils; full circuit availablefor 2-row only.
**Hand is determined by the location of coil connections whenviewed while facing the coil air inlet.
NOTE: Example shown is for a 2-row heating coil, not coated;24 tubes in face; a full circuit, with 8 aluminum fins per inch and gal-vanized casing and 5/8-in. O.D. copper tubes with .020-in. wallthickness. The coil is 120 in. long between tube sheets and hasright-hand, 2-1/2-in. MPT optional steel headers.
CIRCUIT NOMINAL PIPE SIZE (IN.)
H 1-1/2
F 2-1/2
Nu Fin Coils B&W
-
8/8/2019 Hvac2 Coils
7/12
-
8/8/2019 Hvac2 Coils
8/12
1041
COILS
MODEL NUMBER NOMENCLATURE - 28BX
28B X A 4 32 F A A 060 A R
28B - NU-FIN SEPARATESALE COIL
COATINGA = No CoatingB = Epoxy (E-coat) Coating
FIN MATERIAL, FPI AND CASING MATERIALA = AL 8 GALV.B = AL 11 GALV.C = AL 14 GALV.D = AL 8 ST. STL.E = AL 11 ST. STL.F = AL 14 ST. STL.G = CU 8 ST. STL.H = CU 11 ST. STL.J = CU 14 ST. STL.
TUBES IN FACE12-44 Tubes in 2-Tube Increments
NOZZLE AND SIZESee Chart below.
DBTS (DISTANCE BETWEENTUBE SHEETS)In inches from 24 to 144 in 1 inch incre-ments.For Example,
024 = 24 inches121 = 121 inches
ROWS4 - 46 - 68 - 8
TUBE WALL, HAIRPIN(1/2OD COPPER TUBE)A = 0.016 in., STD HAIRPINB = 0.025 in., HEAVY WALL
COIL MODELX= Direct Expansion Coil - 1/2 in.
* Quarter circuit available for 4 row coils with TIF = 12,16, 20, 24,28, 32, 36, 40 only. Half, full or double circuit available with 4, 6, or8 row.
**All Direct-Expansion coils are right-hand and rotated 180 degreesfor left-hand applications.
NOTE: Example shown is for a 4-row evaporator coil, not coated;
32 tubes in face; a full circuit; with 8 aluminum fins per inch and gal-vanized casing; and 1/2-in. O.D. copper tubes with 0.016-in. wallthickness. The coil is 60 in. long between tube sheets and hasright-hand connections.
Nozzle Orifice Size
B - #3/4 J - #5 R - #20C - #1 K - #6 S - #25D - #1-1/2 L - #8 T - #30E - #2 M - #10 U - #35F - #2-1/2 N - #12 V - #40G - #3 P - #15 W- #50H - #4 Q - #17 X - #3 - standard if none specified
Nu Fin Coils B&W
Hand**
R = Right Hand
CIRCUITING*A = Face Split QuarterB = Face Split HalfC = Face Split FullD = DoubleE = Row Split QuarterF = Row Split HalfG = Row Split Full
-
8/8/2019 Hvac2 Coils
9/12
1042
COILS
FACTORY AUTHORIZED REPLACEMENT COILS
Refrigerant Coils
Steam Coils
Chilled Water Coils
Hot Water Coils
TUBES, FINS & HEADERS ARE MADE FROM THE FINEST MATERIALS
Copper (Tubes, Fins and Headers)
Aluminum (Fins)
Steel (Headers, Casings)
QUALITY CONSTRUCTION Slab or Formed
FEATURES:
CARRIER CORPORATION QUALITY
Our coils are made of quality materials and they are manufactured with rigid quality guidelines
Every coil we produce is PRESSURE TREATED AT 400 PSI with air under water
We offer corrosion resistant coatings to protect your coil from harmful environments
ISO 9002 certified supplier
OUR COILS ARE MADE:
To current Carrier engineering design standards as replacements for both Carrier and BDP equipment
SERVICE
Our goal is to provide a quote for any Carrier, Bryant, Day & Night or Payne coil meeting original factory specifications or for
custom built coils within 3 business hours.
Delivery time for most coils is 4-6 weeks (non-stock coils)
Fast Ship is available on most coils but MUST BE QUOTED prior to placing an order. The rush charges will be applied as follows:
-10 day shipment - 25% rush charge
-5 day shipment - 50% rush charge
-2 day shipment - 100% rush charge
FOR MORE INFORMATION ABOUT REPLACEMENT COILS, CONTACT US AT:
PHONE - 1-800-225-COIL or (1-800-225-2645)
FAX - 1-315-432-7966
E-MAIL - [email protected]
1/2O.D Tubes
5/8O.D. Tubes
3/8O.D. Tubes
pg359
-
8/8/2019 Hvac2 Coils
10/12
1043
COILS
FACTORY AUTHORIZED REPLACEMENT COILS FOR 39E AIR HANDLERS28C COIL SECTION (PLATE FIN)
POSITION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SAMPLE COIL NO. 2 8 C X 1 4 1 6 E A 1 0 5 6 H -
INQUIRIES CONCERNING COILS MUST BE ACCOMPANIED BY THE COMPLETE PART NUMBER FOUND ON COIL NAMEPLATE
*Spiral Fin.
COILNO.
POSITION 1, 2, 3 4 5 6 7, 8 9 10 11 12, 13, 14 15 16
COILTYPE MODEL
COILTYPE
HEADERMATERIAL ROWS
TUBESIN FACE CIRCUITING
FINMATERIAL& SPACING
TUBEMATERIAL
& SIZE
LENGTHBETWEEN
TUBESHEETS
DISTRIBUTORNOZZLEORIFICE
HEATPUMP
2
8
C
Q1=Standard
616, 20,24, 28,32, 26
A=Half-No SplitB=Half-12, 12 SplitC=HALF-12, 16 SplitD-FULL-10, 10 SplitE=-12, 12 SplitF=-14, 14SplitH=-9, 10, 9 SplitM=10, 12, 10 SplitT=10, 16, 10 SplitQ=14, 8, 14 Split
A=AL 8/InB=AL 14/InK=CU 8/InL=CU 14/In
Copper1=1/2 O.D.x .017 Wall
4=1/2 O.D.
x .025 Wall
056066071084102126144
FIXED
BLANK
FOR
STANDARD
COIL
S - FOR
SPECIAL
COIL
HOTWATER
U1= Steel2= Brass
12
4
12,16, 20,24, 28,
32, 36
M=HalfT=Full
049056066071076084094102112126136144
NONE
HEATRECLAIM
V 1= Copper46
16, 20,24, 28,32, 36
A=50/50 Face SplitB=Headerless
CHILLEDWATER
W1= Steel2= Brass
468
16,20, 24,28, 32,
36
Q=QuarterH=HalfF=FullD=Double
DIRECTEXPANSION
X
1= Steel
468
16, 20,24, 28,32, 36
A=Face Split QuarterB=Face Split Half
C=Full Split FullD=DoubleE=Row Split QuarterF=Row Split FullH=Row Split Half
Copper
1=1/2 O.D.x .017 Wall
4=1/2 O.D.x .025 Wall
B=#3/4C=#1D=#1E=#2F=#2-1/2G=#3H=#4J=#5K=#6
L=#8M=#10N=#12P=#15Q=#17R=#20S=#25T=#30U=#35V=#40W=#50X=#3
STEAMZ* 1
05, 08,10, 13,16, 20
Z=Full
Copper
3=1 O.D.x .030 Wall
NONE
The sample coil number is a Direct Expansion Plate Fin Coil with Standard Steel Headers, 4 Rows, 16 Tube Face, Quarter
Circuit, 8 Aluminum Fins per inch, 1/2 O.D. x .017 Copper Tubes, with 56 inches between Tube Sheets and Distributor
Nozzle Orifice Size #4.
-
8/8/2019 Hvac2 Coils
11/12
1044
COILS
FACTORY AUTHORIZED REPLACEMENT COILS FOR 39N AND 39T AIRHANDLERS 28N COIL SECTION
The sample coi l number is a Hot Water Coil, Vertical, Uncoated, 2 Row, 24 Tubes In Face, Full Circuit, 8 Aluminum Fins per inch, Galvanized Casings, 1/2
x .017 Wall Standard Hairpin, 257 cm between Tube Sheets, Standard Steel Headers, Right Hand.
POSITION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SAMPLE COIL NO. 2 8 N H 2 2 2 4 F A A 2 5 7 A R
INQUIRIES CONCERNING COILS MUST BE ACCOMPANIED BY THE COMPLETE PART NUMBER FOUND ON COIL NAMEPLATE
COILNO.
POSITION 1, 2, 3 4 5 6 7, 8 9 10 11 12, 13, 14 15 16
COILTYPE MODEL
COILTYPE
COILPOSITION ROWS
TUBESIN FACE CIRCUITING
FIN MATERIALFIN SPACING
CASINGMATERIAL
TUBEMATERIAL
& SIZE
LENGTHBETWEEN
TUBESHEETS (cm)
HEADERSTYLE HAND
HOTWATER
2
8
N
H
46DF
124
10-44Increments
of 2
H=HalfF=Full
A=AL 8 Galv.B=AL 11 Galv.C=AL 14 Galv.D=AL 8 S.S.E=AL 11 S.S.F=AL 14 S.S.G=CU 8 S.S.H=CU 11 S.S.J=CU 14 S.S.
Copper1/2 O.D.
A=.017 WallB=.025 Wall
095105109119120135139155159169179199
207227257287327
A=MPT SteelB=MPT Non-Ferrous
C=Victaulic SteelD=MPT Steel Painted
E=Victaulic Steel Painted
R=RightL=Left
F12
14-36Increments
of 2
Copper5/8 O.D.
B=.020 WallC=.035 Wall
E=.020 CleanableF=.035 Cleanable
CHILLEDWATER
C
4D
468
0 (10)12-44
Incrementsof 2
H=HalfF=FullD=Double
Copper1/2 O.D.
A=.017 WallB=.025 Wall
D46
Copper5/8 O.D.
B=.020 WallC=.035 Wall
DIRECTEXPANSION
X4D
468
12-44Increments
of 2
A=Face Split QuarterB=Face Split HalfC=Full Split FullD=DoubleE=Row Split QuarterF=Row Split HalfG=Row Split Full
E=.020 CleanableF=.035 Cleanable
Copper1/2 O.D. TubeA=.017 WallB=.025 Wall
Nozzle Size
B=3/4C=1D=1-1/2E=2F=2-1/2
G=3H=4J=5K=6L=8M=10N=12P=15Q=17R=20S=25T=30U=35V=40W=50X=3
STEAM Z
46
D
F
1 04-17 F=Full
A=AL 8 Galv.B=AL 9 Galv.
C=AL 12 Galv.D=AL 6 S.S.E=AL 9 S.S.F=AL 12 S.S.G=CU 6 S.S.H=CU 9 S.S.J=CU 12 S.S.
Copper1 O.D. Outer Tube
5/8 O.D. Inner Tube
A=MPT SteelB=MPT Non-Ferrous
-
8/8/2019 Hvac2 Coils
12/12
1045
COILS
FIN COMBS
The convenient way to straighten and clean condenser and evaporator fins. Fin-Tool features
a nylon master handle and 6 nylon injector type heads. Each head slides into the master handle
and tightens in place. The heads are designed to fit units with fin spacing of 4 through 25 fins per
inch. Each head is engraved with its own size and is color coded for fast identification
Eliminates knuckle scraping. The heads are angled so that when inserted in the handle, the
hand is a safe distance from the sharp fins. Fin-tool heads may also be reversed in the handle,
so that combing with an upward stroke (recommended method) my be done easily, with proper
leverage.
Convenient top-hold-handle. The master handle is comfortable to hold, and rugged so its long
lasting.
P/N DESCRIPTION P/N DESCRIPTION
P167-0008 8-FIN PER INCH COMB HEAD (LESS HANDLE) P167-0017 17-FIN PER INCH COMB HEAD (LESS HANDLE)
P167-0009 9-FIN PER INCH COMB HEAD (LESS HANDLE) P167-0018 18-FIN PER INCH COMB HEAD (LESS HANDLE)
P167-0010 10-FIN PER INCH COMB HEAD (LESS HANDLE) P167-0020 20-FIN PER INCH COMB HEAD (LESS HANDLE)
P167-0011 11-FIN PER INCH COMB HEAD (LESS HANDLE) P167-0021 21/22-FIN PER INCH COMB HEAD (LESS HANDLE)
P167-0012 12-FIN PER INCH COMB HEAD (LESS HANDLE) P167-0023 23/24-FIN PER INCH COMB HEAD (LESS HANDLE) *
P167-0013 13-FIN PER INCH COMB HEAD (LESS HANDLE) P167-0001 FIN COMB HANDLEP167-0014 14-FIN PER INCH COMB HEAD (LESS HANDLE) P167-T100 4-14 FIN PER INCH COMB KIT (1 HANDLE & 7 COMB HEADS)
P167-0015 15-FIN PER INCH COMB HEAD (LESS HANDLE) P167-T101 15-23 FIN PER INCH COMB KIT (1 HANDLE & 7 COMB HEADS)
P167-0016 16-FIN PER INCH COMB HEAD (LESS HANDLE) * Approved for use on 25 fin per inch coils.
P911