hq brochure

138
Manufacturers of Heat Pumps, Heating, Cooling & Ventilation Equipment

Upload: iprintphoto

Post on 06-Mar-2016

316 views

Category:

Documents


8 download

DESCRIPTION

HQ Brochure

TRANSCRIPT

Page 1: HQ Brochure

Manufacturers of Heat Pumps, Heating, Cooling & Ventilation Equipment

Tempair units

Tempair is a low energy, air source, heat pump system providing heating, cooling and recovery for occupancy fresh air control. Energy for heating or cooing is provided by the combined operation of a recovery wheel and a variable capacity air source heat pump.

System applications VARV (variable air and refrigerant volume)Variable volume of supply and extract fans controlled from a discharge air pressure sensor.

Single zoneTemperature control from a return air sensor. Variable volume control of fans from a return CO2 sensor, to suit occupancy.

Zone heatingWill operate on recirculation to enable room temperature to rise with zone heaters prior to fresh air operation. Temperature control from return air. Reduced airfl ow available with zone isolation.

Tempered airTemperature control from supply air sensor to give tempered air supply to all zones.

OperationA rotating recovery wheel transfers 70% of the energy from the room exhaust air to the supply air. The heat pump absorbs the energy from the exhaust air to the refrigerant in the outdoor coil, which is then compressed by the compressor, causing its temperature to rise. The indoor coil then transfers the heat to the supply air. The combined output to input power ratio (KW), for the heating provided by the recovery wheel and compressor is 10:1 (this includes the power consumption for air pressure added by the wheel and heat pump system).

System benefi ts• Savings in LPHW, DX or CW pipework cost, space and time

• Utilises renewable energy for air source heat pump.

• Reduced plant space having heating and cooling integral to the unit.

• Variable capacity scroll compressors.

• All controls prewired in units.

• Compressors available with refrigerant pump down to reduce possibility of gas escape.

• Reduced peristaltic loads.

AirSource Ventilation Ltd Unit B1 Lyntown Trading Estate, Lynwell Road, Eccles, Manchester, M30 9QG

Tel: 0161 425 8553 Fax: 0161 637 0232www.air-source.net

Page 2: HQ Brochure

Engineered solutions

AirSource Ventilation manufacture a range of products for commercial and industrial heating and air conditioning. Working closely with customers, we have developed products to o� er the right solution to meet their specifi c needs.

Our knowledge base includes:• Application of products into systems

• Design of refrigeration systems for air cooling or heat pumps with integral digital scroll compressors.

• Packaged units with inbuilt controls

• Producing system controls philosophies

ASV units

A range of Air Handling Units built to client specifi cation to suit any application. O� ering choices of casing, fan type, recovery equipment, heating and cooling media. Available with controls and remote condensing units.

Classair units

Situated in the ceiling void or exposed in the ceiling, the unit is specifi cally designed for classroom full fresh air ventilation. Complete with packaged controls, LPHW coil with valve, DX Heat Pump Coil (optional), start up recirculation dampers, heat recovery heat exchanger, noise attenuation and variable volume fans controlled on CO2. The unit controls temperature as well as fresh air supply to suit occupancy demand. Free cooling and summer boost operates when cooling is required.

The unit is designed to meet the requirements of BB101 and L2A. The SFP is 0.74w/l/s with a power consumption of 200w at 0.27m3/s.

• Full fresh air Heat recovery and recirculation mode.

• Start up just prior to occupancy.

• Quick response to occupancy and temperature changes.

• Low fan power consumption (variable volume backward curved EC fans).

• Unoccupied, reduced set point and switch o� .

• Night pre cooling of thermal mass.

• Occupancy sensors.

Controls

E� ective control of all the components is key to low energy in ventilation systems. The unit is pre-wired with all sensors and controlled from an internal building management system.

2 33

Energy E� ciency

3

Page 3: HQ Brochure

Engineered solutions

AirSource Ventilation manufacture a range of products for commercial and industrial heating and air conditioning. Working closely with customers, we have developed products to o� er the right solution to meet their specifi c needs.

Our knowledge base includes:• Application of products into systems

• Design of refrigeration systems for air cooling or heat pumps with integral digital scroll compressors.

• Packaged units with inbuilt controls

• Producing system controls philosophies

ASV units

A range of Air Handling Units built to client specifi cation to suit any application. O� ering choices of casing, fan type, recovery equipment, heating and cooling media. Available with controls and remote condensing units.

Classair units

Situated in the ceiling void or exposed in the ceiling, the unit is specifi cally designed for classroom full fresh air ventilation. Complete with packaged controls, LPHW coil with valve, DX Heat Pump Coil (optional), start up recirculation dampers, heat recovery heat exchanger, noise attenuation and variable volume fans controlled on CO2. The unit controls temperature as well as fresh air supply to suit occupancy demand. Free cooling and summer boost operates when cooling is required.

The unit is designed to meet the requirements of BB101 and L2A. The SFP is 0.74w/l/s with a power consumption of 200w at 0.27m3/s.

• Full fresh air Heat recovery and recirculation mode.

• Start up just prior to occupancy.

• Quick response to occupancy and temperature changes.

• Low fan power consumption (variable volume backward curved EC fans).

• Unoccupied, reduced set point and switch o� .

• Night pre cooling of thermal mass.

• Occupancy sensors.

Controls

E� ective control of all the components is key to low energy in ventilation systems. The unit is pre-wired with all sensors and controlled from an internal building management system.

2 33

Energy E� ciency

3

Page 4: HQ Brochure

Manufacturers of Heat Pumps, Heating, Cooling & Ventilation Equipment

Tempair units

Tempair is a low energy, air source, heat pump system providing heating, cooling and recovery for occupancy fresh air control. Energy for heating or cooing is provided by the combined operation of a recovery wheel and a variable capacity air source heat pump.

System applications VARV (variable air and refrigerant volume)Variable volume of supply and extract fans controlled from a discharge air pressure sensor.

Single zoneTemperature control from a return air sensor. Variable volume control of fans from a return CO2 sensor, to suit occupancy.

Zone heatingWill operate on recirculation to enable room temperature to rise with zone heaters prior to fresh air operation. Temperature control from return air. Reduced airfl ow available with zone isolation.

Tempered airTemperature control from supply air sensor to give tempered air supply to all zones.

OperationA rotating recovery wheel transfers 70% of the energy from the room exhaust air to the supply air. The heat pump absorbs the energy from the exhaust air to the refrigerant in the outdoor coil, which is then compressed by the compressor, causing its temperature to rise. The indoor coil then transfers the heat to the supply air. The combined output to input power ratio (KW), for the heating provided by the recovery wheel and compressor is 10:1 (this includes the power consumption for air pressure added by the wheel and heat pump system).

System benefi ts• Savings in LPHW, DX or CW pipework cost, space and time

• Utilises renewable energy for air source heat pump.

• Reduced plant space having heating and cooling integral to the unit.

• Variable capacity scroll compressors.

• All controls prewired in units.

• Compressors available with refrigerant pump down to reduce possibility of gas escape.

• Reduced peristaltic loads.

AirSource Ventilation Ltd Unit B1 Lyntown Trading Estate, Lynwell Road, Eccles, Manchester, M30 9QG

Tel: 0161 425 8553 Fax: 0161 637 0232www.air-source.net

Page 5: HQ Brochure

Date: 01/08/12 Issue: 3

natural ventilation

products

tek intonat®www.tekintonat.co.uk0121 766 5005

Page 6: HQ Brochure

contents

Why choose natural ventilation?

Principles of natural ventilation

tek intonat®‑vent

tek intonat®‑dampers

tek intonat®‑stacks

tek intonat®‑fans

tek intonat®‑acoustics

tek intonat®‑revolution

tek intonat®‑controls

tek intonat®‑light

tek intonat®‑heat

tek intonat®‑louvres

tek intonat®‑grilles

tek intonat®‑shade

tek intonat®‑displacement

Projects

Contact details

3

4

6

7

8

9

10

14

13

16

17

18

19

20

21

22

23

Page 7: HQ Brochure

3

Why choosenatural ventilation?

Natural ventilationuses wind speed andtemperature to achieve controlled ventilation, providingthe benefits of naturalair with the security and control of HVACsystems.

Natural ventilation is nota new concept. It hasbeen part of Middle Eastern architecture forthousands of years, butbecame little used as airconditioning was introduced followingWorld War II.

However, as environmental concernshave increased and sustainable design hasbecome more desirable,natural ventilation has

become the preferredsystem for schools andbuildings.

Natural ventilation canalso improve the healthof the buildingʼsoccupants, and hasbeen proven to alleviate Sick BuildingSyndrome, improving concentration rates andreducing absenteeism.

The energy used by natural ventilation isminimal, with the motors used to powerthe dampers the onlydraw on natural resources.

Even hybrid systems,which are a combinationof passive ventilationand fan assistance, are

far more efficient thanHVAC alone.

It therefore gives considerable cost savings through reduced constructioncosts, as well as reduced maintenanceand running costs andfree night‑time cooling.

The ethos of a natural ventilation system is one that fully encompasses the occupantsʼ requirements, the design and constructionas well as the costs andbenefits.

Flexibility and variationin design lead to an individual solution foreach unique building.

Page 8: HQ Brochure

4

Principles of natural ventilation...The Stack EffectStack effect is temperature induced. When there is a temperature difference between two adjoining volumes of air, the warmer airwill have lower density and bemore buoyant, thus will riseabove the cold air creating anupward air stream.

In order for a building to be ventilated adequately viastack effect, the inside and

outside temperatures must bedifferent so that warmer indoor air rises and escapesthe building at higher apertures, while colder, denserair from the exterior enters thebuilding through lower levelopenings.

Stack effect increases withgreater temperature difference and increasedheight between the higherand lower apertures.

tek intonat® offers anumber of natural

ventilation strategiesdepending on your

aesthetic and ventilation

requirements.

Page 9: HQ Brochure

Cross ventilation:w Driven by wind pressure and can be aided by the Stack

Effect if there is a sufficient difference in heights between the two vents.

w Uses wall unitsw Achieves penetration depths of up to 5 times the room height.

5

Displacement Ventilation:w Uses a single roof stack unit which lets in high density cool air

on the windward side and expels warmer, more buoyant exhaust air on the leeward side.

w Useful for exhausting stale air from multiple classrooms and night‑time cooling.

Passive stack ventilation:w Combines the Wind Effect and Stack Effect. Also offers

night‑time cooling.w Uses Wall Unit + Stack Ventilator.w Will achieve up to double the penetration of cross

ventilation.

Single‑side ventilation:w Predominantly driven by wind pressure and can

adequately ventilate smaller rooms with average occupancies.w Uses wall units.w Achieves penetration depths of up to 2.5 times the room

height.

Page 10: HQ Brochure

tek intonat®‑vent

tek intonat®‑vent units are arange of controllable naturalventilation wall units.

w The standard unit comprises of an external louvre, a high specification insulated damper, an actuator and an internal grille.

w These units can be manufactured to any size and to suit either vertical or horizontal configuration.

6

w The units are also available with a choice of internal grilles, including heavy duty grilles for Sports Hall use.

w The wall units are available with acoustic treatment andpre‑heating.

w Our units are acoustically tested by SRL (Sound Research Laboratory Ltd).

Please see the Acoustic and Radiator sections for more information.

Page 11: HQ Brochure

tek intonat®‑dampers

7

tek intonat® now offer aluminium insulated and thermally broken damper able to provide a class‑leading minimum leakage rate combinedwith a ʻUʼ value of 0.581W/m²K.

This provides the highest rate of insulation andshut off and conforms to all new regulationsfrom November 2010.

How this is possible is by attention to detail andcareful assembly allowing class‑leading results to be achieved:

w The case has double thermal breaks and highly insulated and thermally broken blades with a ʻUʼ value of 0.581W/m²K,

w A 50mm flange on roomside to seal against,

minum

minum

sulation

olyurethane

Thermally Broken Frame

Thermally Broken Frame

Thermally Broken Blades

OP

PO

SE

D B

LA

DE

(O

B)

Thermally broken blades

Thermally broken frame

Opposed Blades

Thermally broken frame

Parallel Blades

Atmosphere SideWidth Height Pressure Leakage(mm) (mm) (Pa) (l/s/m²)1400 450 0.2 0.6791400 450 0.2 0.6791400 450 0.2 0.4591400 450 0.2 0.4951400 450 0.2 0.789

Room SideWidth Height Pressure Leakage

(Pa) (l/s/m²)1400 450 0.2 1.0461400 450 0.2 1.2291400 450 0.2 1.1191400 450 0.2 1.0091400 450 0.2 0.789

Frame

Blade

Blade seals

Axles

Jamb seals

Blade insulation

Frame insulation

Damper Test ResultsMaximum leakage at 50Pa per m² over a 10 minute period.Both tests are less than the current regulation of 5m³/hour per m².

w Square to round drive shafts and air tight bearings,

w An accurate length of blade to ensure perfect seal deformation,

w An internal centre brace to prevent bowing of the case,

w Motor mounting bracket, factory fitted and adjusted to provide tight shut‑off,

w Opposed or parallel blade configuration.

Page 12: HQ Brochure

Access from room side only

Access from roof side only

Access from roof side only

Detail A ‑ In the vertical

Detail B ‑Fixed to end of duct

Detail C ‑ Fixed to kerb

Detail Figure 1 ‑ Damper position options

tek intonat®‑stacks

8

tek intonat®‑stackstek intonat®‑stacks are arange of controllable natural ventilation roof terminals.

w The stacks can be manufactured to any size and are available in various shapes including square, rectangular, circular, triangular, and also bespokedesigns can be supplied in wood, copper, stainless steel and other specialist finishes.

w Units can be manufactured from extruded aluminium or GRP.

w The units are usually fixed to a builderʼs curb.

Passive StacksThe tek intonat®‑passive stacks consist of an insulatedroof louvred unit, a high

specification insulateddamper, an actuator and an internal grille.

w The units are usually used inconjunction with low level tek intonat®‑wall units or opening windows with the warm, stale air leaving the stacks.

w The passive stack can be manufactured with removable panels to gain access toa motor or to the inside of the shaft itself.

Damper positions ‑ Thedamper for the tek intonat®‑passive stack can be positioned in a number ofplaces (see Detail Figure 1), attached to the duct in theceiling void for easy motor access, attached to the upstand to keep the shaft drywhen the damper is closed, orfitted behind the louvres toprevent any water ingress orto allow a clear roof to be fitted for natural light tobelow.

Active StacksThe tek intonat®‑active stacksconsist of a louvred roof unit,a high specification insulateddamper, an actuator and an internal grille.

w The units can be used on their own with fresh air entering and stale air leaving through different compartments within the same duct, or it can be used in conjunction with tek intonat®‑low level louvres oropening windows.

Page 13: HQ Brochure

tek intonat®‑fans

9

tek intonat® have developed arange of fans which can beused in conjunction with manyof our natural ventilation products.

Electric or solar powered fanscan be used with tek intonat® ‑passive and ‑active stacks, tekintonat® ‑wall units, or as standalone items like the super quiethybrid fan shown below.

tek intonat® ʼs hybrid fan sys‑tem has been developed for underfloor or ceiling voidmounting to provide a boost to natural ventilation.

This combines full room purgevolume with extremely low regenerated noise and powerconsumption. A valuable addition when the route to corridor becomes congested.

NB

The

back

grou

nd n

oise

leve

l was

NR2

5

Fan positions

Passive & Activeroof units

High levelextract

Classroom transferWall units

Volume and Power Consumption

Speed l/s Amps Watts input

1 180 0.75 180

2 210 0.65 156

3 260 0.58 139

4 280 0.55 132

5 310 0.48 115

6 345 0.43 103

Acoustic Performance

Fan speed NR level at 1 metre

1 Intake 251 Discharge 252 Intake 292 Discharge 273 Intake 283 Discharge 294 Intake 304 Discharge 305 Intake 345 Discharge 306 Intake 366 Discharge 35

The units are fully speed controllable and can provide avolume from 180l/s up to345l/s. Even on high speed theNoise Rating level for the roomdoes not exceed NR35.

Access to the fan motor is provided for maintenance anda range of casing configurations provide flexibility.

tek intonatʼs super quiethybrid fan system

Page 14: HQ Brochure

10

tek intonat®‑acoustics

Straight through attenuationThe attenuators would comprise anouter skin of galvanised steel with aninternal media consisting of splittersand/or linings constructed from fireretardent acoustic insulation.

In some units the insulation wouldbe retained behind perforated or expanded galvanised steel.

Width Height Length Free Area Dnew

1100mm 450mm None 50% 17

1100mm 450mm 100mm 50% 22

1100mm 450mm 200mm 50% 25

1100mm 450mm 250mm 50% 27

1100mm 450mm 400mm 50% 29

1100mm 45mm 600mm 50% 34

The acoustic performance of the attenuators when incorporated into the ventilation units would be:

As independently tested by Sound Research Laboratories Ltd

Attenuators for Natural Ventilation Systems

WIDTH

DEP

TH

HE

IGH

T

S‑type attenuatorsThe S‑type attenuators would comprise an outer skin of galvanisedskin with internal insulation of fireretardent acoustic insulation.

The insulation also has excellentthermal insulation to minimise coldbridging across the unit.

As independently tested by Sound Research Laboratories Ltd

Width Height Depth Free Area Dnew

1400mm 800mm 80mm 0.095 25

1400mm 800mm 80mm 0.078 27

1400mm 800mm 80mm 0.042 33

1400mm 800mm 160mm 0.207 23

1400mm 800mm 160mm 0.190 25

1400mm 800mm 160mm 0.154 28

1400mm 800mm 240mm 0.319 22

1400mm 800mm 240mm 0.302 24

1400mm 800mm 240mm 0.266 27

The acoustic performance of the attenuators when incorporated into the ventilation units would be:

Our natural ventilation units can include an attenuation section to reduce the ingress ofnoise from sources such as road, air traffic andpedestrian including noise from playing areas.

� ����� �

��� ��

��� ��

Page 15: HQ Brochure

11

Attenuators would comprise an outer skin of galvanised sheetwith an internal lining ofacoustic thermal insulation.

The attenuators may also containacoustic splitters comprising rockwool acoustic insulation retained behind perforated or explanded galvanised steel.

As independently tested by Sound Research Laboratories Ltd

The acoustic performance of the attenuators when incorporated into

the ventilation units would be:

Width Height Length Dnew

1000mm 1000mm 1000mm 34

1000mm 750mm 1000mm 21

1000mm 250mm 1000mm 34

1000mm 750mm 1000mm 13Lining only

800mm 750mm 800mm 33

800mm 750mm 800mm 15Lining only

Attenuators for Roof Terminals�������

�������

������

�������

�������

�������

As independently tested by Sound Research Laboratories Ltd

The acoustic performance of the attenuators when incorporated into

the ventilation units would be:

Width Height Length Dnew

1000mm 1000mm 1000mm 39

1000mm 750mm 1000mm 34

1000mm 250mm 1000mm 34

1000mm 750mm 1000mm 16Lining only

800mm 750mm 800mm 35

800mm 750mm 800mm 19Lining only

Passive Unit

Active Unit

Page 16: HQ Brochure

12

tek also design and manufacture attenuators for use when

transferring air between spacessuch as classrooms and corridors.

These can be designed to suit individual sizes and free areas.

Our attenuators have been testedby Sound Research Laboratories

Ltd (SRL) to produce the elementnormalised level difference (Dnew)

ratings for our units.

Attenuated wall unit

Internal grille

Insulateddamper

Louvre

Attenuator

Attenuator positions

Classroom transferWall units

Passive & Activeroof units

tek intonat®‑acousticsAttenuated Natural

Ventilation Units tek intonat® have designed a

selection of attenuators incorporated into natural

ventilation units.

One system incorporates an inline attenuator between the thermally

insulated motorised damper andthe internal face of the unit.

The acoustic loss of the inline attenuator is dependent on the

free area and length of the attenuated section.

Z‑shaped attenuator In order to save space we have developed a range ofZ‑shaped attenuators to enable the acoustic sectionof the natural ventilation unit to be accommodatewithin the depth of the wall.

We can engineer and individually test your requirements providing an acoustic reduction of upto Dnew 37. Attenuators can also be fitted to our active and passive roof units if additional attenuation is required.

Louvre

Attenuator

Insulateddamper

Page 17: HQ Brochure

13

tek intonat®‑revolutionA unique product allowing tek intonat® to heat, ventilate,light and service any space.

These fully‑assembled units arecompletely factury assembledfor minimum installation time.

Each unit is purpose designedto provide:

w Radiant heating of space.

w Tempered fresh air supply, pre‑balanced providing up to 10 ltr/person/second.

w Pre‑attenuated crosstalk incorporated.

w Lighting to your required specification.

w Speakers, sprinklers and alarms.

Adjustable support system supplied.

Various widths, lengths and finishes.

Both perforated and plain,make this product cost effective and a true revolution for single‑source room services.

Page 18: HQ Brochure

tek intonat®‑controls

14

Option 1Hand OperationQuadrant Handle

Pros:w Cost effective

w Easy to see damper status

w Easy to replace

Cons:w Most fix to

casing side

w Who opens?

w Who closes?

Pros:w Concealed

behind radiator casing

Cons:w Who opens?

w Who closes?

Pros:w Robustw Can be sited

anywhere

Cons:w Who opens?

w Who closes?

Option 3Teleflex

Option 2 Offset Handle

Page 19: HQ Brochure

15

Pros:w Automatic

w Clear status

Cons:w Who opens?

w Who closes?

Option 4Manual

Positioning Unit

Option 5StandAlone Room

Controller(incorporating C02 detection,

adjustable set point and

manual override)

Pros:w Fire alarm and heating

interlock time clock for day/night purge

w Intelligent control

w Summer/Winter controlw Classroom purge

Cons:w None

Pros:w Each classroom can be

monitored and controlledat separate conditions

w Fan boost controlw CO2 controlw Room purgew Adjustable set pointsw Data collection

w Status feedbackw Fan boost controlw Fire alarm and

heater interlockw Seasonal adjustmentw Quick intelligent

control

Cons:w None

Option 6Multi Zone Control Package

Page 20: HQ Brochure

tek intonat®‑controls

16

w Low voltage 24V AC/DC operation, 0‑10VDC signal

w Louvres/Dampers can be manually positioned to one ofsix positions at anytime, including fully open and fully closed.

w Optional auto close energy saving feature.

w LED feedback display of louvre/damper position selected.

w Wall/Control panel mountable.

w Optional rain sensor to automatically close louvres/ dampers where necessary.

w Can operate multiple louvres/dampers depending on power supply unit rating.

Manual Positioning Unit

Standard Power Supply Unit sizes:

w PSU8 up to 8 Actuators

w PSU30 up to 30 Actuators

Other sizes available on request

Page 21: HQ Brochure

17

CTCml: Temperature and CO2 sensor controller with manual override and CO2 Level Indicator

CT: Temperature room controller

CTC: Temperature and CO2 room controller

CTm: Temperature room controller with manual override

CTCm: Temperature room and CO2 controller with manual override

CTCI: Temperature and CO2 controller with CO2 level indication

C: Controller, T: Temperature, C: Carbon Dioxide,m: Manual Push Buttons, I: CO2 Indication

Standalone Controllers

w 0/10 VDC heating signal

w 0/10 VDC cooling/ventilation signal

w Frost protection

w Room temp set point adjustable 19°C to 26°C

w Room CO2 set point adjustable 900ppm to 1600ppm

w Pre‑wireable base and plug‑on fascia plate assists in easy, time saving installation.

Our unique range of standalone controllers can control ventilation dampers or automated windows together with localised heating, via on board, temperature or optional CO2

sensors to suit the requirements of eachspecific application.

These controllers can be linked to either atime clock or receive a time signal from a

BMS to activate the optional night coolingprogramme (night cooling only available

with the manual override options).

Temperature Control:The room set point for the control of the ventilation dampers/automated windows can be adjusted in 1°C increments between 21°C and26°C with a seasonal change over and a night coolingoption if a time clock or BMS time signal is available.

Localised heating can also be controlled and is set 2°Cbelow the room set point.

Manual Override (optional):Each room device has manual override capabilitieswhich give the end user control of the ventilation strategy to suit the room application.

The device consists of two push buttons and three LEDlights, the push buttons enable the end user to open orclose the ventilation as required, the LEDs give an indication that the system has either been overriddenor is in Auto mode. Once the system has been overridden it will stay in that mode for 30 minutes, afterthis time the system will revert back to Auto mode.

CO2 Indication (optional):Each room device can also be fitted with a further 3LEDs to identify the level of CO2 within the space; theseare green, amber and red. With green being healthyand red being high levels of CO2 ppm`s.

Night Cooling:To enable the Night cooling pre‑programmed software,the device needs to be in (Night Mode) and the nightcooling enabled, this then cools the building to justbelow the room set point. When the time switch is in(Night Mode), by holding down the open/close buttonsthis will enable this mode to be turned on/off. (Indicated by the Auto LED ON or OFF).

Summer/Winter:The Summer set point can be selected to be belowthe Winter set point, this is 2C below that set value onthe dip switches. To select Summer mode, in (DayMode) hold both the open/close buttons down for 5seconds, lights flash, push the open button for Summer mode, or close button for Winter mode.

Page 22: HQ Brochure

tek intonat®‑controls

18

Four Zone Power Supply Unit (PSU) +Time Switch (TS) Interface UnitThis interface unit comprises of a power supply,coded terminals, frost protection feature, optionaldigital time switch and night cooling (operated bythe time switch or external VFC).

Window ControlThe Window Control Module contains a 24v DCPower Supply and an iWACmodule per Window Actuator that controls via a0/10 VDC positioning signal from a suitable controller.

The WCM features an intelligent ʻself strokingʼ operation and controls the24v DC window actuator insteps to prevent noise disturbance to end users.

The Window Control Module allows only one window to operate at time.

This saves the expense andspace in only needing a DCpower supply rated for thelargest actuator (maximum3 Amp per controller) to beoperated.

Page 23: HQ Brochure

19

A: ONE Control PanelB: ONE Pair of CablesC: ONE Combined Room Unit#D: ONE Power Supply#E: ONE Set of Louvres/Window#F: ONE Modular Wiring InstallG: ONE Web BrowserH: ONE Web Browser Page for SettingsI: ONE Web Browser Page for Time ProgramsJ: ONE Onboard Proven and Tested Software ProtocolK: ONE Open Source BACnet Communication ProtocolL: ONE BACnet over IP outputM: EIGHT Zones# Per Zone

The All New NV8 Natural Ventilation Controls Package

Page 24: HQ Brochure

tek intonat®‑light

20

tekʼs intonat®‑light range bring light to anyenclosed space, either roof‑mounted or incorporated into a passive or active stack.

w Our range of circular light tubes carries free lighting to where it is needed.

wWe can incorporate a solar‑powered fan to aid ventilation and the combination of light and ventilation has no running cost and only minimal maintenance.

wWe are developing even more sizes and variations to ensure tekʼs intonat®‑light range expands for schools and commercial building throughout the UK.

wAll units are fully tested.

wWe offer a full design and installation service, and when combined with our other products we offer a full range of natural ventilation equipment to enhance your project.

Page 25: HQ Brochure

21

tek intonat®‑heat

Following extensive internal and external testingwith full validation on results, tek have developed a full wall‑mounted ventilation andheating system which can be self‑powered onfan‑boosted.

We provide a bespoke wall unit for incorporation in any wall, window or curtainwalling.

Each unit comprises:

w Small format triple turnback tested louvre witha full range of installation frames.

w An insulated case.

w Inline attenuation from a SRL tested and verified design with up to Dnew 37.

w Class‑leading insulated and thermally broken damper, with a ʻUʼ value of 0.581W/m²K. Shut off better than 4m³/hour per m².

w Choice of heat output coils and mounting brackets.

Bespoke range of casings from light, mediumand heavy thickness, to deal with the toughestof installation, and ease of removal with the correct tools provided for maintenance and access.

Choice of colours for all components.

One source with a complete product:

AIR‑HEAT‑ATTENUATION

Page 26: HQ Brochure

tek intonat®‑louvrestekʼs intonat®‑louvre range hasover 30 years of continuous development.

w Our all‑weather louvres are designed and tested to todayʼs rigorous standard for water retention and pressure drop.

w Single, double and triple blade systems including a site assembly system are available.

w Frame styles replace glass or can be incorporated into curtain walling to provide an inlet to any of our ZT range ofnatural ventilation units.

22

w Free‑standing louvre screens and doors in a variety of materials and finishes allow tek intonat® to provide a made‑to‑order product to suit any installation.

w We can design, manufacture and install. Acoustic louvres are also available.

Page 27: HQ Brochure

tek intonat®‑grilles

23

A full range of internal grilles to compliment our natural ventilation terminals featuring:

w Type DFZR ‑ A range of ceiling return air grilles with hinged removable cores

w Type KID ‑ Acoustic transfer grilles to corridor

w Type FDU ‑ Displacement floor units for lecture theatres

w Diplatek displacement units for performance spaces and dance studios

w Slot diffusers

w Sidewall grilles

w Extract grilles

w Swirl diffusers

w Motorised diffusers

w Louvre faced diffusers

w Circular diffusers

Page 28: HQ Brochure

tek intonat®‑shade

tekʼs intonat®‑shade range enhancesour product range to cut down onheat gain and lower nbuilding coolingrequirements. Our systems include all brackets, fixings and installation if required. We design and manufacturein‑house and are available to install.

24

tek intonat®‑shade is a comprehen‑sive range of brise soleil and solarshading from simple horizontal sec‑tions, through various sizes of hori‑zontal and vertical elliptical louvres, to bespoke fibreglass colour panels and motorised systems that track the sun.

Page 29: HQ Brochure

tek intonat®‑displacementtekʼs intonat®‑displacement range offera freedom of design for floor, ceiling and wall‑based displacement units.

w We can provide laser cut customised designs specific to an individual school.

w We have no limit on size or material and regularly feature stainless steel, wood and aluminium.

w Wall‑mounted units can be provided for drama and dance studios.

w Ceiling‑hung terminals can be supplied for design & technology, woodwork and metalwork spaces to provide cooledor heated air exactly where required.

w Floor units for raised floors in stainless steel or plastic, in 150Ø and 200Ø are ex‑stock.

25

Page 30: HQ Brochure

tek intonat®‑acoustic rafts

26

tek intonat®‑acoustic rafts enable our engineer to tailorthe room acoustics so thatspeech can be more intelligiblein a reverberant space. Eachproject is sized and calculatedto provide a bespoke solution.

Sound Absorption Coefficientfor the Acoustic Rafts

125 250 500 1K 2K 4K

0.30 0.80 1.00 1.00 1.00 1.00

Tested by Sound Research Laboratories Ltd in accordance with

BS EN ISO 354:2003

With the current trend to omitlay in grid ceilings and to provide a concrete slab to aidnight cooling, tek intonat®have developed a range of horizontal and vertical acousticrafts.

Page 31: HQ Brochure

Inverness

Dundee

Edinburgh

Glasgow

Newcastleupon Tyne

Middlesborough

Lincoln

Liverpool

Nottingham

NorwichLeicesterShrewsbury

Cardiff

Swansea

Birmingham

Worcester

Gloucester

CambridgeNorthampton

Oxford Chelmsford

LONDONBristol Reading

Taunton

Exeter

Maidstone

tek nationwide projects

27

Derby

Sheffield

York

Chester

Coventry

Warwick

Luton

Bradford

HerefordIpswich

Manchester Rotherham

Bournemouth

Leeds

BrightonSouthampton

tek limited offer a nationwide coverage to supply and installour intonat® range of products.

Whether it is a visit from amember of our Sales team, aContracts Engineer or utilisingour full fitting service, we offer

AreaBalsall CommonBarnsleyBarnsleyBasildon, EssexBedfordshireBedfordshireBexhill‑on‑SeaBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBirminghamBradfordBrentBrentBrentwoodBromsgroveBusheyCambridgeCambridgeCardiffCardiffCleobury MortimerCorbyCoventryCoventryCoventryCoventryCoventryCreweDerbyDerbyEast Barnett

ProjectsHeart of England SchoolKirk Balk SchoolCarlton Primary SchoolPioneer SchoolAlban Middle SchoolRedbourne Upper School Bexhill High SchoolSlade SchoolNansen SchoolHodge Hill Junior SchoolHodge Hill Infant SchoolNelson Mandela Primary SchoolFeatherstone Primary SchoolWard End Primary SchoolSt. Maryʼs Primary SchoolAudley Primary SchoolColmore SchoolStechford SchoolClifton Primary SchoolYardley SchoolChad Vale Primary SchoolThe Oval Primary SchoolRobin Hood Primary SchoolPark Hill SchoolGreet Primary SchoolSummerfield SchoolRegents Park Community Primary SchoolBirmingham Museum Art GalleryHeartlands AcademyKing Edwardʼs SchoolWestgate SchoolAston UniversityBirmingham LibraryBarnes LibraryThornton SchoolNorthfield Manor J&I SchoolFox Hollies School Archbishop Grimshaw SchoolKingshurst SchoolVictoria SchoolSt Bedeʼs Catholic Grammar SchoolNewfield Primary SchoolBrentfield Primary SchoolBrentwood SchoolBromsgrove SchoolHighwood SchoolComberton Primary School Longsands AcademyHywell Dda Primary SchoolHawthorn Nursing HomeLacon Childe SchoolThe Kingswood SchoolSidney Stringer AcademyStivichal Primary SchoolBlue Coat Church of England School Castle Wood SchoolCourthouse Green SchoolSir William Stanier Community SchoolMelbourne Junior SchoolClay Cross Secondary SchoolEast Barnett School

ProjectsBengeworth First SchoolExeter Primary SchoolWest Faversham Community CentreWhitecross SchoolNew Horizon AcademyThomas Fairchild SchoolHackney Free Parochial SchoolSkinners AcademyRoyden Primary SchoolNorth Warwickshire & Hinckley CollegeRoyal Hospital SchoolKeele UniversityWyvern SchoolLattimer SchoolMyton SchoolNorth Leamington SchoolLincoln CollegeHeathcote School & Science CollegeSt Bartholomews Primary SchoolLea Manor High SchoolSamworth AcademyTeeside UniversityGreenford High SchoolWilliam Brookes School

ProjectsTrinity SchoolMalcolm Arnold AcademyUnity CollegeLakenham Primary SchoolColbourne CollegeTaverham SchoolNorman First SchoolThorpe Hamlet First SchoolNethergate SchoolJohn Port SchoolThe Nottingham Emmanuel SchoolJericho Health CentreDidcot Girlsʼ SchoolThe Kingʼs SchoolStamford SchoolHarris SchoolFriesland SchoolTipton Green Junior SchoolYew Tree Primary SchoolHaden Hill Leisure CentreDormston SchoolRoyal Shrewsbury Cancer Care Church Stretton SchoolColbourne & Beaufort SchoolSmiths Wood SchoolLanchester SchoolPark Hall AcademySt Anneʼs Catholic Primary SchoolChurchfield SchoolStamford SchoolThe Nobel SchoolStourbridge CollegeBridgetown SchoolCoppice & Langley SchoolLangley SchoolShelfield Community AcademyTorc High SchoolSidemoor High SchoolTelford CollegeMadeley AcademyThe Kingʼs CE SchoolRSA AcademyBrooklands CollegeMerthyr Tydfil Health ParkWalsall CollegeCulcheth High SchoolWarwick LibraryWarwick Studentsʼ UnionWarwick University Sports CentreWood Green SchoolArk AcademyWexham Girls SchoolAddington SchoolCoppice Performing Arts SchoolHighfields & Penn Fields SchoolWolverhampton Grammar SchoolWalnut SchoolTudor Grange AcademyRiverside SchoolBirchen Coppice Primary SchoolSt Olaveʼs School

AreaNewburyNorthamptonNorthamptonNorwichNorwichNorwichNorwichNorwichNottinghamNottinghamNottinghamOxfordOxfordPeterboroughPeterboroughRugbySandiacreSandwellSandwellSandwellSedgleyShrewsburyShropshireBirminghamSolihullSolihullSolihullSolihullSomersetStamfordStevenageStourbridgeStratford‑upon‑AvonSutton ColdfieldSutton ColdfieldTamworthTamworthBromsgroveTelfordTelfordTettenhallTiptonUxbridgeMerthyr Tydfil, WalesWalsallWarringtonWarwickWarwickWarwickWednesburyWembleyWexhamWokinghamWolverhamptonWolverhamptonWolverhamptonWolverhamptonWorcesterWorcesterWorcesterYork

AreaEveshamExeterFavershamGloucesterHackneyHackneyHackneyHackneyHarlow, EssexHinckleyIpswichKeeleKentKetteringLeamingtonLeamingtonLincolnLondonLoughboroughLutonMansfieldMiddlesbroughMiddlesexMuch Wenlock

a full range of services to thewhole of the UK.

All of our fitting teams carryCSCS cards, as well as an ECITBPassport to Safety our engineers have also beentrained in MEWP equipment.

Many are IPAF and PASMAtrained whilst others have attended supervisor trainingcourses with major builders.tek has an expanding range ofclients throughout the UK,backed by a national networkof fitters local to your projects.

Page 32: HQ Brochure

Manufacturers:

contacts

Agents inthe Northof England:

14 Seeleys Road,Greet,BirminghamB11 2LQ

T: 0121 766 5005

F: 0121 766 5010

E: [email protected]

W: www.tekintonat.co.uk

tek intonat®

Fred HallM: 07527 988896E: [email protected]

Scott FultonM: 07788 713828E: [email protected]

Page 33: HQ Brochure

jeremias group������������������� �������������

11.11.2010

Page 34: HQ Brochure

2

The jeremias group is one of Europe‘s ������������ �������������chimeny systems

������������������ ������������������������� ������ ����

2

Page 35: HQ Brochure

3

Foreword

Strong group of companies with openness and internationality

������ ��� ��������� ��� ������������������������ ���� ��-

������ ������������������� ����� ��������������� �������

�������������� ����������������� ������ ������������������

��������������������!�������� ���������������������������

��� ���� ������� "��� ����� �� ���� ������� #��� ������ ���

�����$�����

%����������������������� �����&����������������������� �

��������������������������'�������������� ���������(�����

���������#���������������$�������������������������)

���������!��� �������������� �������*���������+����-

������������������

,����������/���������4)���������5

6�����! �������! 7��� �! 8������! 9������! :�����! ;������!

<=� �!>��������!8��������!<�������!8��#���!;�������!?��-

������!(��/������

(��&�������������� ���������������������������������-

��������/�������

iService, Quality and Innovation

3

Page 36: HQ Brochure

4

%�����������������.,������� �����

������#��������� ����������������

��������� ����������

Page 37: HQ Brochure

Objectives to be the most succesful in steel chimneys

%������������������+����������������� ��������

Service:��$� ���� ������������ � Quality >���'����������� ���������� ���������������������

InnovationA��/����������������������������������

We invite you to get a personal impression of our products at the following fairs in 2010:

$8����#��B?����C<>D 4E�)4�$4��)4�E)4)

$>����B"�� ������CFGD 4)�)E�$44�)E�E)4)

$:�������7�� �BH�����C9(D EI�)E�$EJ�)E�E)4)

$8���� ����BA�����C:(D E��)E�$EJ�)E�E)4)

$G�=#����B������CGKD )E�)L�$)��)L�E)4)

$"�����<�������B"������C9(D EL�)L�$EM�)L�E)4)

$97>BN����#���C��D 4I�)I�$4M�)I�E)4)

$9�������������B8��:�����#���C;FD 4I�)I�$4J�)I�E)4)

$8>GB"��/��C;FD E)�)I�$EL�)I�E)4)

$�'�������BG���CF�D 4E�)��$4��)��E)4)

$9���������B?�� �����C�8D 4E�)��$4��)��E)40

Page 38: HQ Brochure

%�� ������������������������������������O

7����������������� ������ ����5����������

��������/���������#��

Page 39: HQ Brochure

M

Service

C8��������D

$7����#������� ��������

$7������������������������������� �

$N�������������������� ��������C ���������� �+ D

$���������� ��������������������������������P�)������

PL�)))��

$����������������/��$�� �������������������

Quality

C(� ���������D

$<N<$������� �������

$<N<$���������� �������

$#�������� ����

$�������� ����

$������������� �����$���������

$���������� �������� ����

$(96�����������

$L�$������ �������� ����

Innovation

C:���� ��D

$<���������������������������������������������� ������ �������

$;����� ���������������������� ����� �������

Page 40: HQ Brochure

J

1970 6������

CharacteristicRenovationof chimneys

EM (P)~ 3

1984 6������

Characteristic8������������ �������������

Distribution6������<������������

EM (P)Q4J� Area~ 13.000 m2

1992 6������

Characteristic7����������� ���������-����!�������� ������ ����!����� ���!�����-������������

Distribution������

EM (P)Q�R Area~ 2.000 m2

1993 <=� �;���#��

Characteristic8������������ �������������

Distribution<=� �;���#�� 8����$�������������

EM (P)QI� AreaQ4�)J)�E

1997 :�����

Characteristic8������������ �������������

Distribution:�����!;�����!8 ���������!?���� ��������!F/�����

EM (P)QL)� AreaQ4)�J))�E

2004 7��� �

Characteristic8������������ �������������

Distribution7��� �

EM (VN)~ 3

&�������6����

1984

5�$

6��

���

1997

5�$

:��

���

1993

5�$

<=�

�;

���#

��

1992

58�

8$

6��

���

1970

5���

����

���$

"��

=���

2004

5�$

7���

2006

5�$

>��

����

2007

5�$

;��

���

2008

5�$

8��

��

2009

5�$8

����

/��

2009

5�$F

����

�G

����

��

2010

5�$G

����

��

����������6�#>

J

Page 41: HQ Brochure

R

2006 >������

Characteristic8������������ �������������

Distribution>������

EM (L)QM

AreaQ�I)�E

2007 ;�����

Characteristic8������������ �������������

Distribution;�����

EM (P)~ 33

AreaQEJ��E

2008 8����

Characteristic8������������ �������������

Distribution8����!:�������!FG!"��������-nean area

EM (P)QIR

Area~ 1.000 m2

2009 8����/��

Characteristic8������������ �������������

Distribution8����/��

EM (L)~ 10

2010 G������

Characteristic8������������ �������������

DistributionCroatia

EM (L)~ 3

2009 F�����G������

Characteristic8������������ �������������

DistributionF�����G������

EM (VN)~ 3

�����������

:����� >������ 8���� <=� �;���#�� ;�����

%�������T������

R

Page 42: HQ Brochure

10

&�������$8�8$����� ������

�%$�� �%��#B��#� �%������$��#�B��

�%$���$�� �%$���

�%$� �

�%$����$�� �%$����$�

�%$�� ���� ��������

�%$��

DW - mammut �������$�B�������$7

8�� 8�� 8�(

�%$� �

8���� ��� "����� ������������

7F",$����%$� ��������

Page 43: HQ Brochure

11

�%$��� �%$/� �%$���

�%$������DW - fu DW - al DW - kl �%$/� ���� ���������

8��

�%$���$#����� �� ���

7F;��,$���������� %����� � 7�;;,$���7F;��,$�� �������� �%$:������$ ���� ��������

8H< 78� 78�$V 78$;" 78? 78<

Page 44: HQ Brochure

12

8�#���������X"� ������

�$6������

12

:���� ����

%�������������� <N<$<������� �������

?�������� ���� <N<$A������ �������

>����� /������� A������ �

Page 45: HQ Brochure

1313

�$:�����

:���� ����

A��������������� L�$:����� �������� �������

7������������ �����$��������� :�������

>����� /������� A������ �

Page 46: HQ Brochure

14

8�#���������X"� ������

�$8����

�$<=� �;���#��

14

:���� ����

7������������ ���������� ���� 8������

L�$:����� �������� ������� >����� /�������

:���� ����

Page 47: HQ Brochure

4�

�$;�����

8�8$6������

�$>������

4�

:���� ����

8������

:���� ����

>����$���� ���� 8�������

Page 48: HQ Brochure

4�

9������������:���� ��

?���

"�����

<��#�����

7���/����

7T���F��

?�� ����

Page 49: HQ Brochure

4M

G����������"��������

Cespel

"��� �

H�����

(���

Damaskus

Page 50: HQ Brochure

4J

����������6�#>Y8�8Z7��������4RRE

������������(�� ����������������6�#>!�������Z8�8Z! ��� ������� �� 4RRE��� � ���������������������$�������� �������������!�������������������������� ����������������#��������������������������������-���� ����������������������/���,�� ���#���������������������� �������������������������� ������� ������ �� ��� ����� ��-��������9NI4LLB�N4L)JI�

:�������� �;����,�� ����� �� ���� ��� ��������� ��� �+ �-�����5

[ Basic evaluation / project planning\��+�������������!�������������\ ������������� �� ���������� �� ����� ����� � ������ �� �9N I4LL B �N4L)JI�����#������������� �����������������'���������\ ������������� �� ���������� �� �������������� ������ � ������ �� �9N B�N ��������� ��� ����������� �� ��� ����'���������\ :���������� �� ����+�#�� ����� ��- ��������� ������ ���9NI4LL B�N4L)JI �� �������������� ���������-��� ���������� ��� �+ ������������

[ Execution of construction work\:��������������� ����������������release on site \:���������������/������������\ �������� � ������ �� ������ ����� ������\ <����������� �� ������������ ���� ����management \;����$���$���������������

[ Condition monitoring \� ���������9NI4LLB�N4L)JI

4J

Page 51: HQ Brochure

4R4R

Strengths8����$��$���$����� ������!��������������� � ������#����������������� ���������������!����'��������������������������#�����������������������������

Development(�� ������������������������������������������ ����������������#���������������!��� ���������� ���������������� ����� �����������C������������������������D�������������� ��-�� ����� ��������� ���������

Engineer standards?�������������������������������������������-����������$! ������$����������������������������� ������������ ����� ����9NI4LLB�N4L)JI�������������������

Page 52: HQ Brochure

Germany&�������6�#>,����������8���44$4I�$R4M4M%�������T������

\(���5]IRC)DRJLE$�J�J�)\7��5]IRC)DRJLE$�J�J�J\�"���5����^�����������

SES - Germany����������6�#>,����������8���4E�$R4M4M%�������T������

\(���5]IRC)DRJLE$�J�R) \7��5]IRC)DRJLE$�J�R�I \�"���5����^���$��#���

Russia,,,&�������;��4I4)M�"��/����6�#���!8����G������8������G�����������/���!>���4E!6�#������4E�

\(���5]MCIR�D��IELMJ\7��5]MCIR�D��IELMJ\�"���5����^�����������

France&�������7��� �8���,����9���!?�:�4E47;$�RL)LH���� ������<����

\(���5]LEC)DI��R)EI4�\7��5]LEC)DI��MRIEJE\�"���5����^�����������

www.jeremias.de

Spain&�����������_�8���:���K�#����L�8$IJLI)�����#���� ?�=/���$����_�

\(���5]LIRI�L)4)4)\7��5]LIRI�L)4))�\�"���5����^��������� �����

Czech Republic&�������<K������`/����EEB�<K$ILI)4"���;����� �

\(���5]IE)IM�M)4ELJ\7��5]IE)IM�M)IER�\�"���5����^��������� =

Slovakia&�������8����/��&������ /���R�LBE48G$R�))4K�����

\7��5]IE4CI�D�EIJLEE\(���5]IE4CI�D$�LE�)4�\�$����5����^����������/

Poland&�������8��=�����G�/��=/��:A$�EE))6���=��

\(���5]IJB�4IEJI�E)\7��5]IJB�4IEI4M4)\�"���5��������^�����������

Hungary&�������>�������G���>F$E)I�(b�b/#c������:,:��MMCG4J!RL4�EBdIM!IIIJLD

\7��5]L�$ELBLLE$4)R\(��5]L�$ELBLLE$4)J\�"���5����^�����������

United Kingdom?��������?�������<�����?���������(� �������:��/!9������;���!?���������!?�)L�(�

\(���5]IIC)D4�EMJJJR4I\7��5]IIC)D4�EMJJJR4�\�"���5����^��������$���������� ���/

Rumania8�<�&������������8�:�� ������R;,$L))LRL(��������

\(���5]I)M�E4ELE4J

Page 53: HQ Brochure

COMMERCIAL HEAT PUMPS

ISSUE 1

RESIDENTIAL HEAT PUMPS

Page 54: HQ Brochure

2

The ICS Group has a strong historyproviding refrigeration based heating andcooling equipment to the UK market.The ICS Group have been providing packaged heat pumps for over twenty years and have a strong reputation forproviding innovative high performing air and ground source heat pumps along with a complete specifier supportservice to the fast developing UK heat pump market.

The well established historical relationships between the ICS Group and its manufacturing partners enables ICS HeatPump Technology to continue delivering practical and high quality commercial and residential heat pump ranges tothe UK market.

A complete range of residential heat pumps is available from ICS predominately manufactured by DeLonghiProfessional who have a forty year history of providing heat pumps for both residential new build and retrofitapplications.

For commercial and industrial applications ICS Heat Pump Technology provides equipment manufactured anddesigned to operate in rigorous UK conditions which can be specified for either new build or retrofit applications.ICS Heat Pump Technology exclusively provides the full range of Delonghi professional Prana packaged heat pumps,the enEX range of CO2 sanitary hot water heat pumps and the Tricool range of bespoke heat pump units. Thisflexibility in supply allows ICS Heat Pump Technology to provide the most appropriate correctly specifiedcommercial/industrial heat pump to match your project demands.

ICS HEAT PUMP TECHNOLOGY

EXPERIENCE

Page 55: HQ Brochure

ICS DELONGHI PROFESSIONAL PARTNERSHIP pg 2ICS HEAT PUMP TECHNOLOGY pg 4ICS APPROVED PARTNER PROGRAMME pg 5DELONGHI PROFESSIONAL pg 6-7RESIDENTIAL CASE STUDIES pg 8COMMERCIAL CASE STUDIES pg 9

AIR SOURCE HEAT PUMPS INTRODUCTION pg 10-11MEDIUM TEMPERATURE HEAT PUMPS pg 12-15• AWR DHW 2 Medium Temperature Air Source Heat Pump pg 12-13

• MICS-N Medium Temperature Air Source Heat Pump pg 14-15

HIGH TEMPERATURE HEAT PUMPS pg 16-23• i-KI High Temperature Air Source Heat Pump pg 16-17

• AW HT 65ºC High Temperature Air Source Heat Pump pg 18-19

• i-NRG High Temperature Air Source Heat Pump pg 20-21

• Prana HT High Temperature Air Source Heat Pump pg 22-23

• enEX CO2 High Temperature Air Source Heat Pump pg 24-25

GROUND SOURCE & GEOTHERMAL HEAT PUMPS INTRODUCTION pg 26-27• BWR MTD2 Ground Source & Geothermal Heat Pump pg 28-29

• BWR DHW2 Ground Source & Geothermal Heat Pump pg 30-31

• Prana MTD Ground Source & Geothermal Heat Pump pg 32-33

• Prana DHW Ground Source & Geothermal Heat Pump pg 34-35

BUFFER TANKS pg 36DHW CYLINDERS pg 37FAN COILS & HYDRONICS pg 38-39ECOAMP Modulating In-line Electric Boost Heater pg 40ACCESSORIES pg 41APPLICATION & SPECIFICATION SUPPORT pg 41CPD & TRAINING PG 42TECHNICAL SERVICE SUPPORT pg 43

CONTENTS

3

Page 56: HQ Brochure

4

ICS Heat Pump Technology provides a complete service offering design/specification support,supply/commissioning services and after sales support for air source heat pumps, ground source heatpumps and geothermal heat pumps within both the commercial and residential sectors.

ICS has been providing temperature control systems and heat transfer equipment for an extensive rangeof applications and users since 1988. Twenty years of experience has resulted in an extremely wellestablished business operating throughout the UK, Germany and Ireland employing over 200 people witha combined group turnover of circa £30m.

PROVEN TECHNOLOGYMassive reductions in carbon emissions can be achieved by using heat pumpsand significant cost savings are possible by increasing the efficiency of aproperty when a heat pump system is installed.

Ground source or geothermal heat pumps along with air source heat pumpstake low grade energy from the earth or atmosphere and convert it into highgrade heat energy to be used within the property

Whether a new build project or a retrofit application, the range of heat pumpsprovided by ICS Heat Pump Technology is able to provide a practical and costeffective solution to heating and sanitary hot water requirements from 5kW toover 2,000kW.

A COMPANY YOU CAN TRUST

• An ICS group company

• Established over 20 years

• £30m turnover throughout UK and Europe

• Over 200 specialised and highly skilled employees

• Excellent reputation in climate control services

• Provides a complete service

• Implements a “best advice” policy to all customers

ICS HEAT PUMP TECHNOLOGY

ESTABLISHED

Page 57: HQ Brochure

5

ICS Heat Pump Technology provides a specialist supportservice to their customer base, which is designed toassist the heat pump specifier or installer in maximisingthe fast developing opportunity within the renewableheating sector by specifying the most suitable andefficient system to match project demands.

We understand that providing high quality equipment is only half of the package which is why the ICS SpecifierSupport Service and Approved Partner programmes (APP) has been developed in order to provide the specifieror installer with the complete heat pump support service to accompany the various ranges of air and groundsource/geothermal heat pumps provided by ICS Heat Pump Technology.

The ICS Heat Pump Technology support service is split into four main elements each of which provides the specifieror installer with a range of specialist areas to support their business.

• CONSIDERATIONS TRAINING APP• PRODUCT DAY APP• IN COMPANY SALES & TECHNICAL APP• FIELD SUPPORT APP

• PARTNER BRANDED WEBSITE APP• SALES/PRODUCT SUPPORT LITERATURE APP• ICS-DELONGHI NATIONAL MARKETING APP• DIRECT MARKETING/EXHIBITION

SUPPORT APP

• TECHNICAL SUPPORT DESK APP• FIELD BASED TECHNICAL SUPPORT APP• FACTORY SUPPORT APP• INSTALLER/SPECIFIER INTERNET BASED

PARTNER HUB APP

• CPD - WEB & IN COMPANY APP• INDUSTRY NEWS APP• MCS ASSISTANCE APP• LEGISLATION APP

appapptrainingtraining appappmarketingmarketing £££ appapptechnicaltechnical appappinfocentreinfocentre

APPROVED PARTNER PROGRAMME

HEAT PUMP

SPECIFIER & INSTALLER

SUPPORT

Page 58: HQ Brochure

6

DeLonghi-Professional is the leading refrigerationmanufacturer in Europe and has a worldwidereputation for product reliability and quality with over40 years of market leading experience. The companyhas 7 key manufacturing facilities occupying some75,000 square meters of production space worldwideand achieves a turnover level in excess of 230 millionEuros worldwide.

ICS Heat Pump Technology is the exclusive UK partnerfor the DeLonghi-Professional Prana range of fullyoptimised residential & commercial/industrial heatpumps within the UK & Ireland.

DeLonghi ProfessionalPRODUCT INNOVATION

RESEARCH & DEVELOPMENTHEAT PUMP FOCUS40 YEARS EXPERIENCE

ICS-EXCLUSIVE UK PARTNER

Page 59: HQ Brochure

7

A COMPLETE RANGE OF HEATPUMPS FROM 5KW TO 400KW,A BRAND THAT IS SYNONYMOUSWITH RELIABILITY & QUALITY,

WITH ALL THE ADVANTAGES THAT ONLY

A LEADING MANUFACTURER CAN OFFER.

With more than 40 years of experience in air conditioning, DeLonghiProfessional is truly a leading organisation in the expanding domestic,commercial and industrial heat pump market.

1ST IN EUROPE & 5TH IN THE WORLDThe mission and values that have guided us for 40 years have enabled us to become the numberone manufacturer in Europe and the fifth in the world within the temperature control sector.

The ICS range now includes Air & Ground/Water Source CO2 Heat PumpsWorking on an exclusive basis with the well established manufacturer enex, ics now provide this new market leading range.

The CPD covers heat pump applications ranging from 20kW to 2400kW applied to a variety of applications:

• Space heating - new build and retrofit oil/LPG boiler replacement

• Sanitary/domestic hot water production - conventional prioritised basis and bulk low tariff thermal storage

• Heat recovery - recycle waste heat from production or process areasvia air or water

+ 90,000m² of productive area

+ 5 specialist focused manufacturing plants, 4 located in Italy and1 located in Shanghai China

+ Complete range of products from 1kW to 2400kW

+ Optimised heat pumps from 5kW to 400kW (modular)

+ First heat pump manufactured in 1979

+ Now 12 ranges of air source and ground source/geothermal

+ Residential and commercial equipment

Page 60: HQ Brochure

CASE STUDIES8

Property: 5 bedroom 400sq/m high specification low energy house Application: New build with substantial refurbishment Locations: North West CoastAccreditations: MSC Accredited equipment used Installation: ICS Heat Pump Technology Approved PartnerEquipment: 1 x DeLonghi Professional i-NRG 16.3kW Inverter

Air Source Heat Pump1 x 200L Buffer Tank1 x 300L Optimised unvented cylinder1 x 35L Inertia tank5 x DeLonghi Professional i-life fan coil terminals4 x DeLonghi Professional system/room controllers

RESIDENTIAL CASE STUDY NEW BUILD WITH SUBSTANTIAL REFURBISHMENT

Property: Affordable Housing Application: Refurbishment & New Build Locations: WalesAccreditations: MSC Accredited equipment used Installation: ICS Heat Pump Technology Approved PartnerEquipment: 1 x De-Longhi Professional 6kW Air Source Heat

Pump 1 x Optimised DHW Cylinder 1 x Installation Kit

RESIDENTIAL CASE STUDY BBC DIY SOS LOW COST HOUSING

Property: 5 Bedroom Country HouseApplication: New Build Locations: MidlandsAccreditations: MSC Accredited equipment used Installation: ICS Heat Pump Technology Approved Partner Equipment: 1 x De-Longhi Professional BWR MTD Ground

Source Heat Pump 800m PEX-A Pipework in Horizontal Straight Formation1 x 300L Twin Coil Heat Pump Cylinder 1 x 100L Buffer Tank

RESIDENTIAL CASE STUDY LARGE NEW BUILD

Page 61: HQ Brochure

9

Property: School

Application: New Build School 90kW

Location: Rural Lancashire Town

Installer: North West based - ICS Approved Partner Installer

Equipment: 1 x BWR DHW 0101 1 x BWR MTD 0101,2 x 400L Buffer Tank

COMMERCIAL CASE STUDY NEW BUILD SCHOOL

Property: Superstore

Application: Space heating - Mono-valent system 360kW

Locations: Scotland

Accreditations: MSC Accredited equipment used

Installation: ICS Heat Pump Technology Approved Partner

Equipment: ICS-Delonghi professional 8 x MICS N 0182 Air Source Heat Pumps & 2 x Buffer Tanks

COMMERCIAL CASE STUDY SUPERSTORE HEATING PROJECT

Property: NHS Ambulance Station

Application: Retrofit ‘Off Gas’ Boiler Replacement 20kW

Locations: South West England

Equipment: 1 x 20kW high temperature 65ºC DeLonghi Professional AW HT Air Source Heat Pump

Emitter: Radiators

COMMERCIAL CASE STUDY AMBULANCE STATION RETROFIT

COMMERCIAL CASE STUDY SPACE HEATING & COOLINGProperty: Office & Warehousing Application: Refurbishment 120kW Locations: North West EnglandAccreditations: MSC Accredited equipment used Installation: ICS Heat Pump Technology Approved Partner Equipment: 2 x De-Longhi Professional DHW Air Source

Heat Pumps1 x De-Longhi Professional MICS-N Air Source Heat Pump2 x ICS HTP Buffer Tanks Various DeLonghi Professional Fan CoilsVarious DeLonghi Professional Air Handling Units

Page 62: HQ Brochure

AIR SOURCEMEDIUM & HIGHTEMPERATURE HEAT PUMPS

10

Unit & Capacity

Hot Water

Heating SimultaneousHeating/ Hot Water

Cooling(Optional)

SimultaneousCooling,

Hot Water/Heating

Heat Recovery

ReducedCarbon

Emissions

LowerHeatingCosts

MEDIUM TEMPERATURE AIR SOURCE HEAT PUMPS

AWR DHW2XE SL

20-33kWpg 12 - 13

Commercial

HOT WATERHOT WATERHOT WATER HEATINGHEATINGHEATING HEATINGHEATINGHEATINGHEATING +HEATING +HOT WATERHOT WATERHEATING +HOT WATER COOLINGCOOLINGCOOLING

COOLING +COOLING +HOT WATERHOT WATERCOOLING +HOT WATERCOOLINGCOOLINGCOOLING

Modular

MICS N20-50kWpg 14 - 15

Commercial

HEATINGHEATINGHEATING COOLINGCOOLINGCOOLING MODULARMODULARMODULAR

MCS*

Certificate Number MSC HP0005Heat Pumps

Microgeneration scheme accreditation allowsaccess to grant funding and also guaranteesperformance and manufacturing quality.

* Please contact ICS Technical Support for the current status of MCS ranges as certain models may have MCS Accreditation pending.

Please check prior to specification or selection

MCS ACCREDITATION*

Page 63: HQ Brochure

AIR SOURCE HEAT PUMPSHeat energy is collected from the external ambient airusing the heat pumps integral evaporator coil. This energyis then transferred as high grade heat into the building.

Our air source heat pumps provide a very efficient means of utilising renewable energywhilst being very straightforward in their installation.

The ICS Heat Pump Technology range of air source heat pumps provides units withcapacities from 5kW to 200kW which are suitable for a wide range of applications.

Single phase 240v powered air source heat pump units are available up to a capacityof 14kW and three phase 415v units complete the range for larger residential heatpump and commercial applications.

Modular capability allows for the multiple connection of up to six units operating asone single package, hence large capacity projects can be specified by utilising thismodular configuration approach. The single controller ensures that running hours areequalised & maintained across the various heat pumps whilst also ensuring that thesystem operates with maximum modular part load efficiency at all times.

HIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION

11

Unit & Capacity

i-KI9.5kWpg 16 - 17

Residential

Hot Water

Heating SimultaneousHeating/ Hot Water

Cooling(Optional)

SimultaneousCooling,

Hot Water/Heating

Heat Recovery(Optional)

ReducedCarbon

Emissions

LowerHeatingCosts

HIGH TEMPERATURE AIR SOURCE HEAT PUMPS

HOT WATERHOT WATERHOT WATER HEATINGHEATINGHEATING MODULARMODULARMODULAR

AW HT65ºC

10-27kWpg 18 - 19

Residential &Commercial

HOT WATERHOT WATERHOT WATER HEATINGHEATINGHEATING MODULARMODULARMODULAR

i-NRG16.3kWpg 20 - 21

Residential

HOT WATERHOT WATERHOT WATER HEATINGHEATINGHEATING HEATINGHEATINGHEATINGHEATING +HEATING +HOT WATERHOT WATERHEATING +HOT WATER COOLINGCOOLINGCOOLING

COOLING +COOLING +HOT WATERHOT WATERCOOLING +HOT WATERCOOLINGCOOLINGCOOLING

COOLINGCOOLINGCOOLING

MODULARMODULARMODULAR

Modular

PRANAAW HT

40-100kWpg 22 - 23

Commercial

HEATINGHEATINGHEATINGHOT WATERHOT WATERHOT WATER COOLINGCOOLINGCOOLING MODULARMODULARMODULAR

enEX CO225-100kW

pg 24-25

Commercial

HEATINGHEATINGHEATINGHOT WATERHOT WATERHOT WATER MODULARMODULARMODULAR

MCS*

MCS*

MCS*

MCS*

MCS*

Page 64: HQ Brochure

AWR DHW2 XE SL

Unit Description

The DeLonghi Prana AWR DHW2 XE SL are a unique range of commercialair source heat pumps which are capable of providing a high efficiencycombination of output conditions:

• Heating only

• Simultaneous heating and hot water to 55ºC**

• Hot water only

• Cooling only

• Simultaneous cooling and hot water with up to 100% heat recovery***

• Simultaneous cooling and heating with up to 100% heat recovery***

These units can be specified to suit a particular application and due totheir ability in being able to provide two simultaneous outputs they areable to provide real benefits on both large residential and commercialapplications.

Within the commercial sector the AWR DHW range provides flexibility andreal environmental benefits. These Heat Pumps will provide up to 100%heat recovery which then benefits the user with free heating or hot water.

A growing demand for energy and heat recovery has created a highlyefficient requirement to use these units to recover waste energy fromwaste water or fluid flows, recovering energy from cooling towers orwaste water flows is easily achievable when utilising these units in heatrecovery specification.

Also these heat pump units will provide up to 100% duty on eitherprimary or secondary heat exchangers along with the ability to providea combination of heating and hot water simultaneously or heating andcooling simultaneously with up to 100% heat recovery. This allows theseheat pump units to provide this simultaneous output feature to manageseasonal heating and cooling loads from the same heat pump unit***.

These DeLonghi Professional units are high specification heat pumpswhich are built to exacting standards with regard to efficiency andfunctionality. All the units are European manufactured and benefit fromthe DeLonghi Professional approach to product development and qualitymanagement providing the complete package that would be expectedfrom a premier manufacturer.

Unit Summary

AWR DHW2 XE SL UNITS: AWR

CAPACITY: 20kW-33kW

POWER SUPPLY: Single Phase & Three Phase models

These units provide simultaneous supplies of domestic hotwater and heating/air conditioning.

HIGH EFFICIENCY & PERFORMANCE: COP 3.87 (387% efficient)

*Average coefficient of performance (COP) for the AWR DHW2 XE SL range basedon an ambient temperature of 7ºC and 35ºC flow temperature

NOTE. Actual system efficiency (COP) and annual performance will depend on thedistribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installedin order to provide efficient operational performance.

FEATURES & OPERATIONAL BENEFITS:

• MSC accredited heat pumps, certificate HP0005

• Fully self-contained unit – no external refrigerant pipes

• Standard pipe work installation to suit a plumber or heating engineer

• Highly efficient and flexible design with easy to use controls

• Heating, cooling and domestic hot water provided

• Suitable for large capacity hot water users and simultaneous heating & air conditioning applications

*(COP is shown without circulation pump input power. Please note that unlike most other heatpumps these units incorporate built in circulation pumps, therefore by not including the circulationpump input power we are able to provide a direct performance comparison with other units).

**A higher temperature DHW output is available when the unit is operating in heating mode.The actual available capacity of DHW is dependent on the heating output being provided at anytime. The available part load DHW capacity will vary dependant on the part load capacityavailable in-line with the above.

***The AWR DHW2 XE SL range of units are designed to provide simultaneous heating/DHWand cooling only when operating in ambient temperatures above 10�̊C OR unless operatingwith a year round cooling load equivalent to 100% duty. This 100% cooling load must beconstantly available 365 days per year to match the heating/DHW heat recovery demandsof the unit & system.Please contact ICS Heat Pump Technology Technical Support to confirmthe suitability of this range of equipment for each application.

HEATINGHEATINGHEATING COOLINGCOOLINGCOOLING HOT WATERHOT WATERHOT WATERHEATING +HEATING +HOT WATERHOT WATERHEATING +HOT WATER

COOLING +COOLING +HOT WATERHOT WATERCOOLING +HOT WATER

12

AXIAL

Page 65: HQ Brochure

AWR DHW2 XE SL Air Source Medium Temperature Heat Pumps

Main Components

Note:1. Heating mode: external air temperature 7°C b.s.- 6°C b.u.,inlet water at 30°C and outlet at 35°C2. Heating mode: external air temperature 7°C b.s.- 6°C b.u.,inlet water at 45°C and outlet at 50°C3. Cooling mode: external air temperature 35°C b.s., inlet water at 23°C and outlet at 18°C4. Cooling mode: external air temperature 35°C b.s., inlet water at 12°C and outlet at 7°C5. Sound pressure at 1 meter distance from the external surface of the unit, free field.

* According to the Eurovent standard without circulation pump input power.

• Housing and base are made from hot-galvanized epoxy powder coated sheet metal

• Hermetic scroll type compressors, equipped with the crankcase heater and thermal protection

• Condensers finned tubes with copper and aluminium fins high exchange surface(100% fully quality tested); sub cooling circuit to prevent the icing at the base

• Axial electric fans, external rotor, electric motor with a 6-pole fitted with thermalprotection, housed in aerodynamic profile with safety grill.- continuous fan speed regulation with pressure switch for modulating load management

• Primary stainless steel (AISI 316) plate heat exchanger with high efficiency andlow pressure drop (providing domestic hot water or heating) positioned directlyafter the compressor which gives an efficient high temperature output providingan output kW capacity up to 100% of the Heat Pump duty.

• When combined with the secondary heat exchanger (cooling duty) these unitswill provide either full or partial heat recovery which is constantly optimised via the advanced logic adjusting controller.

• Secondary stainless steel plate heat exchanger providing an output kW capacityup to 100% of the heat pump duty with high efficiency and low pressure dropprovides the supply of both hot or cold water for the application with or withoutany hot water or heating production on the primary heat exchanger.

• The water circuit comes complete with:- primary circuit water pump for domestic hot water or heating circuit- secondary circuit plant side water pump for heating or cooling circuit- differential pressure switch on plant side- expansion vessel Heat Pump circuit only- safety valve (6 bar)- manual filling assembly- Pressure gauge- venting and draining valve

• Soft start for 230V/1/50Hz units AWR DHW/S

NB: Optional equipment includes a range of tanks & cylinders plus standardinstallation packs, see current price list or contact ICS HPT or your distributor for details.

L

H

W

13

AWR DHW2 XE SL 0065t 0101t 0065ts 0101ts

Nominal Heating power (1) kW 19,4 29,3 19,4 29,3

Total absorbed power (2) kW 4,70 7,10 4,70 7,10

COP 4,13 4,13 4,13 4,13

COP EN14511 4,11 4,16 4,11 4,16

Cooling capacity (3) kW 20,9 31,4 20,9 31,4

Total absorbed power (2) kW 5,60 8,40 5,60 8,40

EER 3,73 3,74 3,73 3,74

EER EN14511 3,84 3,82 3,84 3,82

Cooling capacity with total recovery (4) kW 19,2 28,8 19,2 28,8

Total absorbed power kW 5,20 7,70 5,20 7,70

Recovery heating capacity kW 24,1 36 24,1 36

Heating capacity (5) 19 28,8 19 28,8

Total absorbed power (2) kW 5,90 8,80 5,90 8,80

COP 3,22 3,27 3,22 3,27

Cooling capacity (6) kW 15,1 22,8 15,1 22,8

Total absorbed power (2) kW 5,10 7,80 5,10 7,80

EER 2,96 2,92 2,96 2,92

Compressor type SCROLL SCROLL SCROLL SCROLL

No. Compressors N. 1 1 1 1

Refrigerant R407C R407C R407C R407C

No. fans N. 2 3 2 3

Plant side pump type (7) Ci Ci Ci Ci

Recovery side pump type (7) Ci Ci Ci Ci

Electrical power supply V-Ph~Hz 400-3N~50 400-3N~50 400-3N~50 400-3N~50

Start-up current A 101 118 56 65

Sound power (8) dB(A) 73 74 73 74

Sound pressure level (9) dB(A) 57 58 57 58

LxHxW mm 1700x1700x650 1700x1700x650 1700x1700x650 1700x1700x650

Operational weight kg 348 390 348 390

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with orwithout prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification andequipment details at point of quotation and/or order.

Page 66: HQ Brochure

MICS-N

MODULARMODULARMODULARCOOLINGCOOLINGCOOLINGHEATINGHEATINGHEATINGSUITABLE FORSUITABLE FOR

SWIMMING POOLSSWIMMING POOLSSUITABLE FOR

SWIMMING POOLSUnit Description

The DeLonghi Professional MICS-N commercial heat pump range providesa fully optimised Air Source Heat Pump installation with the capability toprovide a modular package in excess of 200kW in capacity which operatesas a single unit. This provides a very high specification air sourceinstallation for both large residential and commercial applications.

• A high COP is achieved at nominal conditions with a high performanceand specification designed for medium temperature heating only.

• These units have twin compressors for maximum efficiency when operating on partial load duty. They also have the ability to operate with four heat pumps acting as a single unit i.e. three slaves and onemaster where the lead unit will interface with a BMS system or equivalent.

• These units are reversible and provide heating or cooling to match thedemands of the project.

• Each MICS-N single unit incorporates a twin compressor design whichprovides a highly efficient output when operating under part load conditions i.e. in modular multi unit/multi compressor configuration.

• Circulation pumps are incorporated within the unit to give a completeinstalled solution with a high specification and highly efficient system.The full floating control and modulating performance of the system provides a highly intelligent control function to give maximum performance and efficiency.

• The units also incorporate a vertical air discharge system which allowsfor compact positioning of single or multiple units to fit into restrictedlocations.

• These DeLonghi Professional units are high specification heat pumps which are built to exacting standards with regard to efficiency and functionality. All the units are European manufactured and benefit fromthe DeLonghi Professional approach to product development and quality management providing the complete package that would be expected from a premier manufacturer.

NB: Optional equipment includes a range of tanks & cylinders plusstandard installation packs, see current price list or contact ICS HPT or yourdistributor for details.

Unit Summary

MICS-N UNITS: AWR

CAPACITY: 20kW-50kW (modular parallel systems)

POWER SUPPLY: Three Phase models

These units provide medium to large capacity installations with a highefficiency modular system which can provide heating and airconditioning from 20kW to 1000kW (modular).

HIGH EFFICIENCY & PERFORMANCE: COP 3.85 (385% efficient)*Average coefficient of performance (COP) for the MICS-N range based on an ambienttemperature of 7ºC and 35ºC flow temperature.

COP 3.77 (377% efficient @ 2ºC ambient & 35ºC flow temp)

NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiitersystem utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficientoperational performance.

FEATURES & OPERATIONAL BENEFITS:

• MSC accredited heat pumps, certificate HP0005 • Provides heating & cooling with a number of control options• Full BMS compatability with single control function for multiple units• Modular system which provides flexibility and ease of installation• Vertical discharge fan with compact footprint for ease of positioning• Very efficient twin compressor design provides high part load

efficiency when providing heating and cooling on an annual basis• Fully self-contained unit – no external refrigerant pipes• Water based system which allows the heating and A/C installation to

be carried out by a mechanical contractor • Highly efficient and flexible design which can be specified as a

package with fan coils/internal air handlers

*(COP is shown without circulation pump input power. Please note that unlike most other heatpumps these units incorporate built in circulation pumps, therefore by not including the circulationpump input power we are able to provide a direct performance comparison with other units).

14

***modular capability

Certificate Number MSC HP0005Heat Pumps

Microgeneration scheme accreditation allowsaccess to grant funding and also guarantees performance and manufacturing quality.

AXIAL

Page 67: HQ Brochure

MICS-N Air Source Medium Temperature Heat Pumps

Main Components

MICS-N 0072 0092 0122 0152 0182

Heating capacity at full load (1) kW 20.7 26.2 34.5 43.6 48.9Absorbed power at full load (1) kW 5.3 6.8 9.2 11.3 12.5COP at full load (1) 3.9 3.85 3.75 3.86 3.91Nominal Cooling capacity (1) kW 17.3 21.8 30.3 37.4 42.5Total absorbed power (1) kW 6.50 9.30 10.7 13.4 15.5EER (1) 2.66 2.34 2.83 2.79 2.74ESEER (1) 3.86 3.75 3.78 3.92 3.96Nominal water flow (1) m3/h 3 3.80 5.20 6.40 7.30Nominal Heating power (2) kW 20.2 26.1 33.9 42.6 47.9Total absorbed power (2) kW 6.50 8.60 11.2 14 15.4COP (2) 3.11 3.02 3.03 3.04 3.11Absorbed current (3) A 14 17.7 23.9 29.3 31.3Nominal water flow (3) m3/h 3.50 4.50 5.90 7.40 8.30Hydraulic connections (3) inches 1”1/4 1”1/4 1”1/4 1”1/4 1”1/4Operational weight (3) kg 310 330 410 450 480No. fans (3) N. 1 1 2 2 2Airflow (3) m3/h 9000 9000 18000 18000 18000Compressor type SCROLLRefrigerant R410ASound pressure level (3) dB(A) 68 68 71 71 71Sound power dB(A) 80 80 83 83 83Electrical power supply V-Ph~Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50Hz 400V-3N~50HzLength mm 1040 1040 1630 1630 1630Height mm 1630 1630 1630 1630 1630Width mm 790 790 790 790 790

Note:1. 1. Evaporator water (in/out) 12/7°C, condenser air (in) 35°C and

(in/out) condenser water 30/35°C, outdoor air temperature +7ºCbased on Eurovent standard

2. Outdoor air temperature +7ºC CBS, 85% RH, water inlettemperature +40ºC, outlet +45ºC. Compressors in operation: A+B

3. Noise level measured at 1 m in open field conditions

4. Outdoor air temperature +35ºC, water inlet temperature +12ºC,outlet +7ºC. Compressors in operation: A+B

• Modular designed to minimise required installation space• A Keyboard Master Control (KMPH) is the central control for multiple

Units connected together with a primary function of supervisingThe operation of all the modules in synergy together.

• Flex Energy technology for automatic air flow, water flow and water temperature control

• Electronic thermostatic valve• 20-50kW single units• 50kW-1000kW packaged systems• Twin compressor system per unit, maximum part load efficiency• Compact footprint• Vertical discharge fans• The hydraulic unit comes complete with:

- variable delivery pump- expansion tank- filling unit- discharge valve- air valve

H

W L

15

***modular capability

MODULARMODULARMODULAR

MODULAR CAPABILITY

The MICS-N range is designed for modular application to accommodate multi unit larger capacity requirements***.

INTERNAL VERSION

• MICS-CN ducted unit• 20kW- 50kW capacity• Modular capability• Provides specification

flexibility

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with orwithout prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification andequipment details at point of quotation and/or order.

Page 68: HQ Brochure

i-KI

SUITABLE FORSUITABLE FORSWIMMING POOLSSWIMMING POOLS

SUITABLE FORSWIMMING POOLSMODULARMODULARMODULARHOT WATERHOT WATERHOT WATER COOLINGCOOLINGCOOLINGHEATINGHEATINGHEATING BI-VALENTBI-VALENTBI-VALENT

Unit Description

• The 60ºC DeLonghi Professional i-KI 9.5kW Inverter drivenair source heat pump is suitable for either new build or retrofit applications with efficient performance and a lownoise level of 50dB(A) at 1m. A circulation pump is incorporated within the unit for ease of installation and a remote weather sensor is providedwhich will allow the unit to be positioned in any location whilst operatingwith a high performance weather compensated heating output.

• The integrated controller accurately follows the actual load of the building utilising a modulating DC inverter source fan and modulatingcirculation pumps in order to maximise performance.

• The i-KI incorporates the new DeLonghi Professional integrated heating zone + DHW + solar controller as standard specification. This allows the specifier to incorporate all the required elements of system control with complete flexibility within the single i-KI heat pump controller.

• The 50dba low noise performance of this unit allows for flexibility in positioning and location and the in-built modulating circulation pump provides the installer with a unit which is very straightforward to install andcommission. The NADI integrated controller also provides full domestic hotwater prioritisation controlling the system three port valve (optional, notsupplied as standard), in addition the i-KI is fully weather compensated for efficient operation and performance via the remote wired weather sensor.

• The modulating circulation pump ensures that energy usage and output are matched to meet demand ensuring that maximum performance and control is maintained at all times, a suitably rated buffer tank should be incorporated within the system design to ensure efficient dedicated systemvolume is provided.

• The new DeLonghi Professional NADI integrated electronic controller provides a high level of application flexibility and functionality. The remotekeyboard kit with wired indoor and outdoor weather sensors allows dynamic control of delivered water temperature. The controller ensures full optimisation of comfort within the property and increases overall energy efficiency, providing the following functions:

+ Single heating zone control for radiator, underfloor or fan coil+ Multiple heating zone control available via optional expansion module+ Solar thermal control via optional extension module+ Remote weather sensor for accurate weather compensated performance+ Anti-legionella cycle control for DHW cylinder+ Bi-valent control for additional heat source+ Modulating circulation pump and source fan provide maximum efficiency

Unit Summary

i-KI UNITS: Inverter Air Source

CAPACITY: 9.5kW

POWER SUPPLY: Single Phase models

This compact and high performing air source heat pump provides ahigh temperature 60ºC output temperature in ambients as low as -5ºC and a 55ºC output temperature when operating in a -20ºCambient condition. The unit provides a low noise level of 50dB(A) at1 meter and is complete with circulation pump, remote weathersensor plus integrated heating zone control and solar thermal control*.

High performance, high specification and high value.

HIGH EFFICIENCY & PERFORMANCE: COP 4.02 (402% efficient)**Coefficient of performance (COP) for the 9kW i-KI based on an ambient temperature of7ºC and 35ºC flow temperature

NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiitersystem utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficientoperational performance.

FEATURES & OPERATIONAL BENEFITS:

• 60ºC output temperature at -5ºC ambient• Low noise level of 50dB(A) at 1m• Freeze prevention drain pan heating included as standard• High performance, delivers 55ºC at -20ºC ambient temperature• Integrated NADI control for heat pump, heating zones* and solar thermal*• Inverter driven providing flexibility in application and performance• Remote weather sensor provides flexibility in positioning and location• Built in circulation pump allows for simple installation

* standard unit controller for single heating zone control, optional extension modules allow furtherheating zone control and solar thermal control

r HFCR-410A

AXIAL

16

**(COP is shown without circulation pump input power. Please note that unlike most other heatpumps these units incorporate built in circulation pumps, therefore by not including the circulationpump input power we are able to provide a direct performance comparison with other units).

Certificate Number MSC HP0005Heat Pumps

Microgeneration scheme accreditation allows access to grant funding and also guarantees performance and manufacturing quality.

Page 69: HQ Brochure

i-KI Air Source High Temperature Heat PumpsHIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION

Main Components

• Condensate drain pan kit.• Condensing coil protection grills• Housing and base are made from hot-galvanized epoxy powder coated sheet metal• High efficiency and low pressure drop stainless steel (AISI 316) water

exchangers and differential pressure switch• Rotary DC inverter compressor, equipped with the crankcase heater and

thermal protection• Condensers finned tubes with copper and aluminium fins high exchange surface

(100% fully quality tested).• Axial variable speed fan, electric motor, housed in an aerodynamic profile with

safety grill• Remotely positioned low external air temperature device

- fan speed regulation which maximises efficiency at part load

• The NADI electronic controller menu allows management of:- circulation pump on the system side- domestic hot water production via control of the external three-way valve (not supplied)

- 24 hour timer operation for a cylinder heater- control of supplementary heating element - outdoor temperature sensor for modulating set point weather compensation- heating zone control, single as standard with multiple zone option- solar thermal control via optional extension module

• The water circuit comes complete with:- variable flow circulation pump for all models- differential pressure switch on plant side- expansion vessel (Heat Pump circuit only)- safety valve- manual filling assembly- pressure gauge- manual air vent valve

NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your distributor for details.

i-KI 0031mNominal Heating power kW 1 9.55 Total absorbed power kW 2 2.31COP** 4.02Compressor type SCROLL INVERTER DC No. Compressors N. 1 Refrigerant R410A No. fans N. 1 Fan type 3 i-CiPlant pump type 3 i-Ci Heat pump circuit expansion vessel Included Electrical power supply V-Ph~Hz 230-1~50 Sound power dB(A) 4-5 64 Sound pressure level dB(A) 4-5 50

Dimensions 0031mL mm 850H mm 882D mm 330Operational weight kg 85

Note:

1. Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C 2. Total input is obtained from compressor input and fan input. 3. i-Ci= Brushless DC motor4. Sound Pressure level according to ISO 9614 and Eurovent 8/15. Average Sound Pressure level above one reflecting surface (Q=2) at 1 metre

882

330 850

17

MODULARMODULARMODULAR

MODULAR CAPABILITY

The i-KI range is designed for modular application to accommodate multi unit larger capacity requirements***.

BI-VALENTBI-VALENTBI-VALENT

BI-VALENT INTEGRATED CONTROLIntegrated bi-valent systems are now becoming more relevant, a heat pump operating with a secondary heat source is a practical option should theapplication demand this type of system. The integrated controller will provide an interface between the heat pump and the secondary heat sourcesubject to appropriate system design.

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with orwithout prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification andequipment details at point of quotation and/or order.

Page 70: HQ Brochure

AW HT 65ºC

HOT WATERHOT WATERHOT WATERHEATINGHEATINGHEATING MODULARMODULARMODULARUnit Description

The DeLonghi AW HT represents the next generation of air source heatpumps with an output temperature of 65ºC. Unlike medium temperatureheat pumps these units are able to provide an output of 65ºC in ambienttemperatures as low as -12ºC with a minimum operating temperature of-20ºC.

• This DeLonghi AW HT range of air source heat pumps provides an extremely high level of performance and a high level of specificationwhich makes them ideal for retrofit applications for both the residentialand commercial sectors.

• The fact that the installer has to only provide minimal modifications tothe existing heating distribution system and hot water cylinder/tank (due to the 65ºC output temperature of the unit) provides significant installation benefits in terms of cost & time on a retrofit or boiler replacement application**.

• The nominal refrigeration COP* (efficiency) of these units is very highaveraging over 4.15 but importantly the performance of these units inreducing ambient temperatures is also at an extremely high level.

• These units incorporate a built in heating system circulation pump, control for hot water production including Y Plan valve (optional, not supplied as standard) operation along with full weather compensationand sophisticated controls.

• This advanced control means that these units are able to operate witha minimum dedicated system volume of 14 litres per nominal kW of Heat Pump capacity. A buffer tank is required to achieve maximum operational efficiency in order to provide thermal mass and efficient defrost capability (buffer tank capacity to reflect the minimum dedicated system volume requirement of the heat pump specified). Ifin doubt please confirm actual buffer tank requirements with ICS HPTtechnical support.

• DeLonghi Professional units are high specification heat pumps which are built to exacting standards with regard to efficiency and functionality. All the units are European manufactured and benefit fromthe DeLonghi Professional approach to product development and quality management providing the complete package that would be expected from a premier manufacturer.

Unit Summary

HT UNITS: AW HT CAPACITY: 10kW-27kWPOWER SUPPLY: Single Phase & Three Phase models

These units provide an output temperature of 65ºC for eitherheating or DHW production.

HIGH EFFICIENCY & PERFORMANCE: COP 4.15 (415% efficient)*Average coefficient of performance (COP) for the AW HT range based on an ambienttemperature of 7ºC and 35ºC flow temperature

COP 3.77 (377% efficient @ 2ºC ambient & 35ºC flow temp)

NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiitersystem utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficientoperational performance.

FEATURES & OPERATIONAL BENEFITS:

• MSC accredited heat pumps, certificate HP0005 • Full DHW and heating control • Built in circulation pump • High COP 4.22• Pro extended control for high efficiency• Minimum defrost time with a minimum operating temperature of -20°C• 65°C operation at -12°C ambient temperature

**Please note that this unit is capable of providing a maximum output temp of 65°C, theunit will provide this output temperature for heating only at the times of year where it isnecessary. ie: The weather compensation control incorporated within the unit will providecorrespondingly lower output temperatures to match external ambient temperatures,therefore providing a high seasonally corrected Coefficient of Performance.

*(COP is shown without circulation pump input power. Please note that unlike most other heatpumps these units incorporate built in circulation pumps, therefore by not including the circulationpump input power we are able to provide a direct performance comparison with other units).

18

***modular capability

Certificate Number MSC HP0005Heat Pumps

Microgeneration scheme accreditation allows access to grant funding and also guarantees performance and manufacturing quality.

AXIAL

Page 71: HQ Brochure

HT 65ºC Air Source High Temperature Heat PumpsHIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION

Main Components

AW HT 0031MS 0041MS 0041T 0061T 0071T 0041TS 0061TS 0071TS

Nominal heating power (1) kW 10.4 14.9 14.1 19.7 26.6 14.1 19.7 26.6Total absorbed power (2) kW 2.50 3.50 3.30 4.70 6.1 3.30 4.70 6.1COP 4.10 4.12 4.14 4.12 4.26 4.14 4.12 4.26Heating capacity (3) kW 10.4 14.3 14.3 19.7 27.1 14.3 19.7 27.1Total absorbed power (2) kW 3 4 4 5.60 7.4 4 5.60 7.4COP 3.30 4.48 3.48 3.45 3.58 3.48 3.45 3.58Heating capacity (4) kW 9.10 12.5 12.5 17.5 23.5 12.5 17.5 23.5Total absorbed power (2) kW 2.50 3.30 3.30 4.60 5.9 3.30 4.60 5.9COP 3.44 3.66 3.66 3.72 3.88 3.66 3.72 3.88Heating capacity (5) kW 7.80 11.4 11.4 14.8 21.2 11.4 14.8 21.2Total absorbed power (2) kW 3.80 5.40 5.40 7.60 10.4 5.40 7.60 10.4COP 1.97 2.06 2.06 1.91 1.99 2.06 1.91 1.99Compressor type SCROLL EVIN. Compressors N. 1Refrigerant R407CN. fans N. 2 2 2 2 3 2 2 3Plant side pump type (6) CiElectrical power supply V-Ph~Hz 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50Start-up current A 44 45 64 101 99 35 55 55 Sound power (7) dB(A) 70 70 70 71 74 70 71 74Sound pressure (8) dB(A) 55 55 55 56 59 55 56 59Length mm 900 900 900 900 1470 900 900 1470Height mm 1240 1390 1390 1390 1700 1390 1390 1700Width mm 420 420 420 420 570 420 420 570Operational weight kg 150 160 160 170 320 160 170 320

Note:

• Housing and base are made from hot-galvanized epoxy powder coated sheet metal

• High efficiency and low pressure drop stainless steel (AISI 316) water exchangers, with anti-freeze heating element and differential pressure switch

• High efficiency cycle EVI Hermetic Scroll Compressor (with hot gas direct injection into the compressor) to reach 65°C, with the crankcase heater and thermal protection

• Condensers finned tubes with copper and aluminium fins high exchange surface (100% fully quality tested); sub cooling circuit to prevent the icing atthe basement

• Axial electric fans, external rotor, electric motor with a 6-pole fitted with thermal protection, housed in aerodynamic conveyor profile with safety grill

• A condense collecting tray within water discharge• Condensing coil protection grills

• Soft start for 230V/1/50Hz units (45 amps)• The water circuit comes complete with:

- circulation pump for all models- differential pressure switch on plant side- expansion vessel – Heat Pump circuit only- safety valve- manual filling assembly- pressure gauge

• Remote outside air sensor (wired)• Remote internal keyboard kit (wired)• The electronic board PRO EXTENDED allows for control of:

- circulation pump on system side- domestic hot water control by external Y Plan three-way valve (accessory)- outdoor temperature sensor for modulating set point weather compensation

NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your supplier for details.

L

H

W

19

1. Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.2. Total input is obtained from compressor input and fan input3. Water in-out 40/45°C (plant side), outdoor air temperature 7°C b.s./ 6°C b.u.4. Water in-out 30/35°C (plant side), outdoor air temperature 2°C b.s./ 1°C b.u.5. Water 65°C, outdoor air temperature -7°C b.s./ 1°C b.u.6. Ci=Circulator; Ce=Centrifugal7. Sound power level according to ISO 9614 and Eurovent 8/18. Average sound pressure level above one reflecting surface (Q=2) at 1 meter

from the outside dimensions of the unit

MODULARMODULARMODULAR

MODULAR CAPABILITY

The AW HT range is designed for modular application to accommodate multi unit larger capacity requirements***.

BI-VALENTBI-VALENTBI-VALENT

BI-VALENT INTEGRATED CONTROLIntegrated bi-valent systems are now becoming more relevant, a heat pump operating with a secondary heat source is a practical option should theapplication demand this type of system. The integrated controller will provide an interface between the heat pump and the secondary heat sourcesubject to appropriate system design.

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve theright to change update or alter the specification & details of any item shown with or without prior notice forwhatever reason. The information provided within the product guide and/or data sheets is intended for guidancepurposes only, please confirm actual current specification and equipment details at point of quotation and/or order.

Page 72: HQ Brochure

i-NRG

Unit Summary

i-NRG UNITS: Inverter Air Source External or Internal Positioning

CAPACITY: 16.3kW

POWER SUPPLY: Single & Three Phase models

This new generation low noise air source heat pump allows for completeflexibility in terms of location (internal or external) and applicationproviding heating, cooling and domestic hot water with full heat recovery,providing a 60ºC output temperature when operating in -10ºC ambients.

HIGH EFFICIENCY & PERFORMANCE: COP 3.9 (390% efficient)Coefficient of performance (COP) for the i-NRG range based on an ambient temperatureof 7ºC and 35ºC flow temperature.

NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiitersystem utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficientoperational performance.

FEATURES & OPERATIONAL BENEFITS:

• 60ºC output temperature for heating and/or domestic hot water• Low noise 52dBA, when positioned externally or internally• Optional ducting kit for internal positioning• Twin circuit providing heating or cooling and also DHW outputs• Simultaneous heating and cooling outputs with 100% heat

recovery• Inverter driven providing flexibility in application and performance

Certificate Number MSC HP0005Heat Pumps

Microgeneration scheme accreditation allows access to grant funding and also guarantees performance and manufacturing quality.

r HFCR-410A

AXIAL

• Expansion module for additional heating circuits• Additional heating zone controllers• Expansion module for solar thermal collector• Ducting kit for Internal Positioning

Main Accessories

20

HEATINGHEATINGHEATING COOLINGCOOLINGCOOLING HOT WATERHOT WATERHOT WATERHEATING +HEATING +HOT WATERHOT WATERHEATING +HOT WATER

COOLING +COOLING +HOT WATERHOT WATERCOOLING +HOT WATER

external internal

Unit Description

• The new 60ºC DeLonghi Professional i-NRG Inverter air source heat pump provides exactly the energy required by the distribution system within the property at any time.

• The integrated controller accurately follows the actual load of the building utilising a modulating DC inverter source fan and modulating circulation pumps in order to maximise performance.

• i-NRG is the new generation heat pump for all year round operation in any operating mode: single cycle (air conditioning, heating, domestic hot water) as well as combined cycle (simultaneous heating or DHW and cooling).

• Domestic hot water production is provided by a dedicated heat exchanger for high temperature heat recovery providing partial or 100% free domestic hot water production. The unit can be installed internally (ducted) or externally, ensuring complete flexibility to match the demands of each application.

• Designed to operate in ambient temperatures as low as -20ºC the i-NRG rangeis more than capable of operating with high efficiency in UK & Irish winter temperatures.

• The new DeLonghi Professional NADI integrated electronic controller provides ahigh level of application flexibility and functionality.

• The remote keyboard kit with wired indoor and outdoor temperature sensors allows dynamic control of delivered water temperature, this ensures full optimisation of comfort within the property and increases overall energy efficiency.

+ Single heating zone control for radiator, underfloor or fan coil+ Multiple heating zone control available via optional expansion module+ Solar thermal control via optional extension module+ Remote temperature sensor for accurate weather compensated performance+ Anti-legionella cycle control for DHW cylinder+ Bi-valent control for additional heat source

• DeLonghi Professional units are high specification heat pumps which are built to exacting standards with regard to efficiency and functionality. All the unitsare European manufactured and benefit from the DeLonghi Professional approach to product development and quality management providing the complete package that would be expected from a premier manufacturer.

***The AWR DHW range of units are designed to provide simultaneous heating/DHW and coolingonly when operating in ambient temperatures above 10˚̊C OR unless operating with a year roundcooling load equivalent to 100% duty. This 100% cooling load must be constantly available 365days per year to match the heating/DHW heat recovery demands of the unit & system.Pleasecontact ICS Heat Pump Technology Technical Support to confirm the suitability of this range ofequipment for each application.

Page 73: HQ Brochure

i-NRG Air Source High Temperature Heat PumpsHIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION

Features

i-NRG 0061 Single Phase 0061 Three Phase

Nominal Heating power kW 1 16.3 16.3 Total absorbed power kW 2 4 4 COP 3.91 3.94 Cooling capacity kW 3 19.6 19.7 Total absorbed power kW 2 5.4 5.4 EER 3.62 3.66 Cooling capacity with total recovery kW 4 17.9 18 Total absorbed power kW 4 4.9 4.9 Recovery heating capacity kW 4 22.6 22.6 Compressor type SCROLL INVERTER DC No. Compressors N. 1 1 Refrigerant R410A kg 6.55 6.55 No. fans N. 1 1 Air Flow m3/h 8000 8000 Useful head Pa 60 60 Plant side pump type 5 i-Ci i-Ci Recovery side pump type 5 i-Ci i-Ci Max system and DHW pressure water side kPa 250 250 System and DHW safety valve kPa 300 300 Heat pump circuit expansion vessel l 10 10 Electrical power supply V-Ph~Hz 230-1~50 400-3N~50 Sound power dB(A) 6-9 68 68 Sound pressure level dB(A) 7-9 52 52Length mm 8 750 750 Length mm 9 1535 1535 Height mm 1600 1600 Width mm 1050 1050 System hydraulic connections inch 1"1/4 1"1/4 DHW hydraulic connections inch 1"1/4 1"1/4 Operational weight kg 260 260

Note:

• Structure and base coated in hot galvanised epoxy powder coated steel

• DC Inverter Scroll Compressor

• Stainless steel (AISI 316) with high efficiency and low pressure drop plate toplate exchanger (domestic hot water side), positioned directly after the compressor ensuring efficient domestic hot water production, operating in either full recovery or partial heat recovery.

• Plant side plate heat exchanger stainless steel AISI 316 with high efficiency and low pressure drop meets the supply of both hot or cold water for the property. Regardless of the domestic hot water demand the DC inverter scrollcompressor will adjust to meet demand.

• Electronic expansion valve and NADI controller

• Finned coils made with copper pipes and aluminium fins with large exchangesurface area (100% fully quality tested)

• Axial DC Inverter Source Fan housed in aerodynamic conveyor profile with safety grill

• Low external air temperature device provides continuous fan speed regulationvia the pressure switch

• The water circuit is provided complete with:

+ Variable flow circulating pump plant side

+ Variable flow circulating pump domestic hot water side

+ Expansion tank

+ Safety valve

+ Pressure gauge

+ Manual filling assembly

1. Water in-out 30/35°C (plant side), outdoor air temperature 7°C b.s./ 6°C 2. Total input is obtained from compressor input and fan input. 3. Water in-out 23/18°C (plant side), outdoor air temperature 35°C b.s. 4. Water in-out 23/18°C (plant side), water in-out 45/50°C (total recovery side)

5. i-Ci= Brushless DC pump6. Sound Pressure level according to ISO 9614 and Eurovent 8/17 Average Sound Pressure level above one reflecting surface (Q=2) at 1 metre8 Indoor Installation9 Outdoor Installation

1600

1050

750

1535

21

MODULARMODULARMODULAR

MODULAR CAPABILITY

The i-NRG range is designed for modular application to accommodate multi unit larger capacity requirements***.

BI-VALENTBI-VALENTBI-VALENT

BI-VALENT INTEGRATED CONTROLIntegrated bi-valent systems are now becoming more relevant, a heat pump operating with a secondary heat source is a practical option should theapplication demand this type of system. The integrated controller will provide an interface between the heat pump and the secondary heat sourcesubject to appropriate system design.

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided withinthe product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.

Page 74: HQ Brochure

Prana AW HT22

COOLINGCOOLINGCOOLINGHEATINGHEATINGHEATING HOT WATERHOT WATERHOT WATER MODULARMODULARMODULARUnit Description

The DeLonghi Professional Prana AW HT range represents the nextgeneration of commercial air source heat pumps with an outputtemperature of 65ºC. Unlike medium temperature heat pumps these unitsare able to provide an output of 65ºC in ambient temperatures as low as-12ºC with a minimum operating temperature of -20ºC.

• This DeLonghi Professional Prana HT range of air source heat pumps provides an extremely high level of performance and a high level of specification which makes them ideal for either new build or retrofit applications within the commercial sector.

• The specifier can choose to carry out a minimal amount of modifications to an existing heating system when applying a 65°C Prana HT to a retrofit application and as a result can potentially achievesignificant installation benefits in terms of cost & time savings when replacing existing Oil or Gas fired boilers.

• The nominal refrigeration COP* (efficiency) of these units is very highaveraging over 4.2 but importantly the performance of these units inreducing ambient temperatures is also at an extremely high level.

• Designed to operate in ambient temperatures as low as -20ºC the PranaHT range is more than capable of operating with high efficiency in UK& Irish winter temperatures.

• These units incorporate a complete control system for prioritised sanitary hot water production along with full weather compensated heating controls. This allows the unit to function efficiently as either amedium or high temperature heat pump with prioritised 65ºC sanitaryhot water production (a reversible option for chilled water productionis also available).

• This advanced control means that these units are able to operate withvery low system volumes which reduces buffer tank size and can considerably reduce installation costs.

• These DeLonghi Professional units are high specification heat pumps which are built to exacting standards with regard to efficiency and functionality. All the units are European manufactured and benefit fromthe DeLonghi Professional approach to product development and quality management providing the complete package that would be expected from a premier manufacturer.

Unit Summary

PRANA AW HT UNITS: AW HT

CAPACITY: 40kW-100kW

POWER SUPPLY: Three Phase models

These units provide heating and hot water up to 65ºC outputtemperatures with a reversible cooling option also available.

HIGH EFFICIENCY & PERFORMANCE: COP 4.2 (420% efficient)

*Average coefficient of performance (COP) for the Prana AW HT range (LN-CA) based onEN14511 conditions.

Average COP 3.6 (360% efficient) @ 7ºC ambient & 45ºC flow temp.

NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiitersystem utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficientoperational performance.

FEATURES & OPERATIONAL BENEFITS:

• 65°C operation at -12°C ambient temperature • Prioritised 65ºC sanitary hot water production (100% duty)• Weather compensated heating control (max 65ºC output)• Reversible unit also available• Multiple unit capability for parallel operation• High COP 4.20• MSC accredited heat pumps (relevant models)• Maximum defrost efficiency• Minimum design operating temperature -20°C

*Please note that this unit is capable of providing a maximum output temp of 65°C, theunit will provide this output temperature for heating only at the times of year where it isnecessary. ie: The weather compensation control incorporated within the unit will providecorrespondingly lower output temperatures to match external ambient temperatures,therefore providing a high seasonally corrected Coefficient of Performance.

*(COP is shown without circulation pump input power. Please note that unlike most other heatpumps these units incorporate built in circulation pumps, therefore by not including the circulationpump input power we are able to provide a direct performance comparison with other units).

***modularcapability

Certificate Number MSC HP0005Heat Pumps

Microgeneration scheme accreditation allows access to grant funding and also guarantees performance and manufacturing quality.

AXIAL

Page 75: HQ Brochure

Prana HT Commercial Air Source High Temperature Heat PumpsHIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60ºC OUTPUT TEMPERATURE AT A -5ºC AMBIENT CONDITION

23

Main Components

Prana AW HT 0122CA 0122LN-CA 0152CA 0152LN-CA 0202CA 0202LN-CA 0262CA 0262LN-CA 0302CA 0302LN-CA

Pt (1) (kW) 37.6 38.0 50.6 50.2 67.9 68.5 83.7 84.7 100.7 99.0

Pa (1) (kW) 8.9 8.9 12.2 12.1 16.3 16.4 19.9 20.0 23.2 23.0

COP (1) 4.22 4.27 4.15 4.14 4.17 4.18 4.21 4.24 4.34 4.30

COP EN14511:3 (1) 4.21 4.25 4.13 4.12 4.14 4.15 4.17 4.20 4.30 4.27

Pt (2) (kW) 38.0 38.4 51.3 51.0 68.8 69.4 84.9 85.8 102.0 100.3

Pa (2) (kW) 10.7 10.7 14.4 14.3 19.4 19.4 23.6 23.7 27.7 27.6

COP (2) 3.55 3.59 3.57 3.56 3.55 3.58 3.60 3.62 3.68 3.63

Pf (3) (kW) 34.1 34.0 43.8 43.8 60.3 60.2 76.4 76.2 91.6 90.3

Pa (3) (kW) 11.5 11.6 14.7 15.0 20.4 20.5 25.9 26.1 31.3 32.9

EER (3) 2.97 2.93 2.98 2.93 2.96 2.94 2.95 2.92 2.93 2.74

Sound Power level dB(A) 84 80 86 82 87 83 87 83 87 84

Sound Pressure Level dB(A) 52 49 54 51 55 51 55 51 55 52

Circuits 2 2 2 2 2 2 2 2 2 2

Length 1695 1695 2195 2195 2745 2745 2745 2745 2745 2745

Width 1120 1120 1120 1120 1120 1120 1120 1120 1120 1120

Height 1450 1450 1450 1450 1450 1450 1650 1650 1650 1650

• Housing and base are made from hot-galvanized epoxy powder coated sheet metal

• High efficiency and low pressure drop stainless steel (AISI 316) water exchangers, with anti-freeze heating element and differential pressure switch

• High efficiency cycle EVI Hermetic Scroll Compressor (with hot gas direct injection into the compressor) to reach 65°C, with the crankcase heater and thermal protection

• Condensers finned tubes with copper and aluminium fins high exchangesurface (100% fully quality tested)

• Axial electric fans, external rotor, electric motor with a 6-pole fitted with thermal protection, housed in aerodynamic conveyor profile with safety grill

• A condense collecting tray within water discharge

• Outside air sensor wired

• Remote internal keyboard kit wired (optional)

• The electronic board PRO EXTENDED allows for control of:- circulation pump on system side- domestic hot water control by external Y Plan three-way valve (accessory)- outdoor temperature sensor for modulating set point weather compensation

NB: Optional equipment includes a range of tanks & cylinders plus hydronic kits, see current price list or contact ICS HPT or your distributor for details.

W3000

The W3000 controller offers the latest control and operating functions developed directly by DeLonghi Professional utilising their experiencegained within the field of heat pump design and related plant engineering. The keypad is generously sized with a full operating status display,the controls and detailed LCD make access to machine settings easy and safe. Temperature regulation with a proportional logic capability is relatedto the return water temperature which provides the ability to satisfy simultaneously heating, sanitary hot water and cooling requests with no needfor mode changeover. The diagnostics include full management of alarms with black box function and an alarm recorder for analysis of unitperformance. Monitoring is achieved through either DeLonghi Professional devices or with various options for interfacing to ModBus, Bacnet or Echelon & LonTalk protocols. Thecontroller has the compatibility to operate with a remote keyboard (single controller management of up to 10 modular units) along with a full time clock function for efficientprogramming of operation (standard 4 days and 10 time bands). Exclusive self-adaptive defrost logic, monitoring multiple operational and ambient parameters are incorporatedwhich allow the unit to reduce the number and duration of the defrost cycles with the benefit of increased overall energy efficiency.

Lw

H

Note:1. Heating 35ºC flow/7ºC ambient2. Heating 45ºC flow/7ºC ambient3. Cooling 12ºC/7ºC 35ºC ambient

MODULARMODULARMODULAR

MODULAR CAPABILITY

The Prana AW HT range is designed for modular application to accommodate multi unit larger capacity requirements***.

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with orwithout prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification andequipment details at point of quotation and/or order.

Page 76: HQ Brochure

Where to use ICS-enEXHeat Pumps?

Whenever large quantities of hot water are needed and/or largepeaks of thermal energy are required the eNEX C02 system allowsthe specifier to install a BREEAM excellent heat pump system withhigh efficiency.

• Hotels • Student Accommodation

• Hospitals • Schools & Colleges

• Restaurants • District Schemes

• Food Processing • Centralised Apartment Systems

• Laundries • Sports & Leisure Centres

• Process Industries • Manufacturing Plants

How does it work?

enEX CO2 Heat Pump has a single unit nominal capacity of 25kWand 50kW, multiple unit systems can be configured to provideover 200kW.

The ICS-enEX CO2 Heat Pump is able to provide an efficient meansof generating a low cost/low carbon store of thermal energy overnight by taking advantage of low cost night time or off peakelectricity tariffs.

This allows the system to generate a high temperature store of80°C+ hot water that can then be drawn down over the followingday. This package provides an ideal direct replacement for existingsanitary and hot water boilers for applications where highvolumes of hot water are required.

Utilising R744 (CO2) as the refrigerant allows the ICS-enEX CO2Heat Pump in single or multiple unit configuration to be specifiedon low carbon projects where a natural refrigerant is required.

Sanitary Hot Water

• 3,000L Intelligent layered cylinder stores at 90ºC heat pump + solar thermal: heat pump 20ºC to 90ºC

• Ideal bi-valent system with bulk/batch sanitary hot water storage via 20kW heat pump: (20kW x 10 hours = 200kW)

enEX CO224

HOT WATERHOT WATERHOT WATERHEATINGHEATINGHEATING MODULARMODULARMODULAR

3 60ºC to 80ºC output temperatures• Air & ground/water source heat

pumps 20kW-200kW• No supplementary heating required• CO2 natural refrigerant provides

BREAM benefits

3 Achieve renewable targets

3 100% sanitary hot water production

3 Thermal storage via high capacity 3,000L+ storage systems

3 Generate overnight low cost thermal storage using reduced tariff electricity

Certificate Number MSC HP0005Heat Pumps

Microgeneration scheme accreditationallows access to grant funding and alsoguarantees performance andmanufacturing quality.

Page 77: HQ Brochure

30

25

20

15

10

5

0-10 -6 -2 2 6 10 14 18

Heating Capacity

Electrical Power

Temperature water in: 10ºCTemperature water out: 65ºC

eneEX CO2 Air Source High Temperature Heat Pumps25

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter thespecification & details of any item shown with or without prior notice for whatever reason. The information provided within the product guide and/or datasheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.

air Heat 25 enEX CO2 Air Source

Voltage supply 380V - 50Hz

Dimensions mm 1650 x 900 x 1850

Temperature water in range ºC 5 - 30

Temperature water out range ºC from 50 - 85

Evaporator type finned coil

Gas cooler coaxial - plate

PS bar 80 - 120

Temperatue outdoor air ºC -10 - +40

Nominal data with ambient air 7ºC Temp. In/Out water 10ºC/65ºC

Heating capacity kW 21.1

Power input kW 5.4

COP 3.9

Hot water production l/min 5.5

kW

Outdoor Air Temperature ºC

900

1850

1650

C

D A

B

A. In ground sinkB. Out ground sinkC. In waterD. Out hot water

30

25

20

15

10

5

00 2 4 6 8 10 12 14 16

Heating Capacity

Electrical Power

Temperature water in: 10ºCTemperature water out: 65ºC

air Heat 25 enEX CO2 Air Source

Voltage supply 380V - 50Hz

Dimensions mm 950 x 950 x 2100

Temperature water in range ºC 5 - 30

Temperature water out range ºC from 50 - 85

Evaporator type plate

Gas cooler coaxial - plate

PS bar 65 - 120

Temperatue outdoor air ºC 0 - 25

Nominal data with water inlet from source at 10ºC Temp. In/Out water 10ºC/65ºC

Heating capacity kW 22.6

Power input kW 5.5

COP 4.1

Hot water production l/min 5.9

kW

Inlet Water Temperature from Heat Source ºC

950

2100

950

eneEX CO2 Ground Source & Geothermal Heat Pumps

MODULARMODULARMODULAR

MODULAR CAPABILITY

The enEX CO2 range is designed for modular application to accommodate multi unit larger capacity requirements***.

25kW capacity unit is illustrated below (50kW unit also available)

25kW capacity unit is illustrated below (50kW unit also available)

Page 78: HQ Brochure

GROUND SOURCE& GEOTHERMALHEAT PUMPS

26

Unit & Capacity

BWR MTD25-43kWpg 28-29

Residential

Hot Water

Heating SimultaneousHeating/ Hot Water

Cooling(Optional)

SimultaneousCooling,

Hot Water/Heating

Heat Recovery

ReducedCarbon

Emissions

LowerHeatingCosts

GROUND SOURCE/GEOTHERMAL HEAT PUMPS

HOT WATERHOT WATERHOT WATER HEATINGHEATINGHEATING COOLINGCOOLINGCOOLING

BWR DHW25-40kWpg 30-31

Residential &Commercial

HOT WATERHOT WATERHOT WATER HEATINGHEATINGHEATING HEATINGHEATINGHEATINGHEATING +HEATING +HOT WATERHOT WATERHEATING +HOT WATER COOLINGCOOLINGCOOLING COOLINGCOOLINGCOOLING

COOLING +COOLING +HOT WATERHOT WATERCOOLING +HOT WATER

HOT WATERHOT WATERHOT WATER HEATINGHEATINGHEATINGHEATING +HEATING +HOT WATERHOT WATERHEATING +HOT WATER COOLINGCOOLINGCOOLING

COOLING +COOLING +HOT WATERHOT WATERCOOLING +HOT WATER

Prana MTD40-360kW

pg 32-33

Commercial

HOT WATERHOT WATERHOT WATER HEATINGHEATINGHEATING MODULARMODULARMODULAR

Modular

Prana DHW& TR

40-360kWpg 34-35

Commercial

HEATINGHEATINGHEATING COOLINGCOOLINGCOOLING MODULARMODULARMODULAR

enEX CO225-100kW

pg 24-25

Commercial

HOT WATERHOT WATERHOT WATER MODULARMODULARMODULAR

MCS*

MCS*

Certificate Number MSC HP0005Heat Pumps

Microgeneration scheme accreditation allowsaccess to grant funding and also guaranteesperformance and manufacturing quality.

* Please contact ICS Technical Support for the current status of MCS ranges as certain models may have MCS Accreditation pending.

Please check prior to specification or selection

MCS ACCREDITATION*

Page 79: HQ Brochure

27

A full range of ground collectors, manifolds and geothermal services are availableto support each ICS Heat Pump Technology ground source/geothermal and watersource heat pump range. The various types of ground source/geothermalequipment and services available can be provided by strategic partner companiesassociated with ICS Heat Pump Technology*.

Please contact ICS Technical Sales Support for details of groundsource/geothermal partner companies and service providers.

1. PE or PEX geothermal pipe work

2. A complete selection of manifolds

3. Ground loop Thermal Fluids incorporating inhibitor & glycol protection

4. Ancillary ground source/geothermal equipment & sundry items

5. Geothermal consultancy and support

6. Turnkey project delivery via the ICS Partner Network

GROUND SOURCE HEAT PUMPSHeat energy is collected from the ground at a depth of 1.2 metresusing horizontal collectors and is transferred via the heat pump ashigh grade heat into the building.

GROUND SOURCE HEAT PUMPSICS Heat Pump Technology provides the complete range of groundsource heat pumps. This range of units allows the selection of themost efficient ground source heat pump to match the requirementsof each project.

GEOTHERMAL HEAT PUMPSThis range of units allows the selection of the most efficientgeothermal heat pump to match the requirements of each project.

Co-efficient’s of performance in excess of 4.5 (1kW of electricalpower gives 4.5kW of heat energy out) can be achieved in theoperating conditions experienced within the UK & Ireland.

GEOTHERMAL HEAT PUMPSICS Heat Pump Technology provides the complete range ofgeothermal heat pumps. This range of units allows the selection ofthe most efficient geothermal heat pump to match the requirementsof each project.

GROUND COLLECTORS/GEOTHERMAL SERVICES

*ICS Heat Pump Technology are able provide introductions to various organisations/companies and as such offer no guarantee or warranty whatsoever with regard to the suitabilityor otherwise of these various organisations/companies concerning the provision, supply or delivery of any equipment or services provided regardless of circumstances whatsoever.

Page 80: HQ Brochure

BWR-MTD2

HEATINGHEATINGHEATING COOLINGCOOLINGCOOLING HOT WATERHOT WATERHOT WATER

Certificate Number MSC HP0005Heat Pumps

Unit Description

The DeLonghi Professional BWR MTD2 ground source & geothermal heatpump ranges are able to provide heating or cooling and domestic hotwater whilst providing a high level of specification with the benefit ofvalue and efficiency.

• These units incorporate a built in heating system circulation pump, a built in source pump to function with horizontal or vertical collectors. Full control for hot water production including Y Plan valveoperation is also incorporated along with full weather compensationoptions, also the units are able to function with any Heat Pump optimised thermal store or cylinder.

• The modulating source pump controls efficiency and maximises theperformance on part loads by drawing the correct amount of sourcewater through the unit to match the load requirement of the property at any time.

• This advanced control means that these units are able to operate with very low system volumes, a minimum open circuit volume of 3.5 litres per nominal kW of Heat Pump capacity is required which can remove the need for buffer tanks and secondary pumps hencereducing installation costs considerably.

• The high specification standard of the BWR/WWR MTD2 range provides a high specification unit with efficient performance in a practical and cost effective functional package.

• These DeLonghi Professional units are high specification heat pumpswhich are built to exacting standards with regard to efficiency and functionality. All the units are European manufactured and benefit from the DeLonghi Professional approach to product development and quality management providing the complete package that would be expected from a premier manufacturer.

Unit Summary

MTD2 UNITS: WW/WWR & BW/BWR

CAPACITY: 5kW-43kW

POWER SUPPLY: Single Phase & Three Phase models

These units provide heating and hot water up to 55°C with theoption to also provide heating and cooling.

HIGH EFFICIENCY & PERFORMANCE:

COP 4.28 (428% efficient)

BWR MTD2 source flow temperature 0ºC/-3ºC & output flow temp 35ºC*

COP 5.52 (552% efficient)WWR MTD2 source flow temperature 5ºC/10ºC & output flow temp 35ºC*

*Average COP for the BWR & WWR MTD2 ranges

NOTE. Actual system efficiency (COP) and annual performance will depend on thedistribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installedin order to provide efficient operational performance.

FEATURES & OPERATIONAL BENEFITS:

• MSC accredited heat pumps, certificate HP0005 • Full DHW and heating control• Heating only or reversible Heat Pump• Built in plant and circulation pump• High value and high performance• 55ºC output temperature

Microgeneration scheme accreditation allows access to grant funding and also guarantees performance and manufacturing quality.

*(COP is shown without circulation pump input power. Please note that unlike mostother heat pumps these units incorporate built in circulation pumps, therefore by notincluding the circulation pump input power we are able to provide a direct performancecomparison with other units).

28

AXIAL

Page 81: HQ Brochure

BWR-MTD2 Ground Source & Geothermal Heat Pumps

BWR MTD2 0011ms 0025ms 0031ms 0041ms 0025t 0031t 0041t 0061t 0071t 0091t 0101t 0121t

Nominal Heating power (1) kW 5.40 7.30 9.20 11.7 7.50 9.10 12.2 16 19.8 23 26.5 33.3Total absorbed power (2) kW 1.34 1.82 2.35 2.80 1.74 2.10 2.80 3.50 4.40 4.90 5.80 7.30COP Eurovent 4.03 4 3.92 4.18 4.31 4.33 4.36 4.57 4.50 4.69 4.57 4.56Cooling capacity (3) kW 7.10 9.80 12 15.1 9.50 12 15.7 21.3 26.9 30.7 34.8 44.8Total absorbed power (2) kW 1.60 1.96 2.53 3.27 1.84 2.50 3.30 4.10 5.15 5.95 7 8.80EER Eurovent 4.44 5 4.74 4.62 5.16 4.80 4.76 5.20 5.22 5.16 4.97 5.09Heating capacity (4) 5.20 7.10 9 11.3 7 8.70 11.8 15.2 18.8 21.8 25.1 31.9Total absorbed power (2) kW 1.70 2.30 3 3.60 2.20 2.70 3.70 4.40 5.60 6.20 7.40 9COP Eurovent 3.06 3.09 3 3.14 3.18 3.22 3.19 3.45 3.36 3.52 3.39 3.54Cooling capacity (5) kW 5.20 7.20 8.80 11.3 7.30 8.90 11.8 15.7 19.8 22.9 26 33.4Total absorbed power (2) kW 1.53 2 2.60 3.20 1.90 2.41 3.19 4 5.10 5.80 6.80 8.40EER Eurovent 3.40 3.60 3.38 3.53 3.84 3.69 3.70 3.93 3.88 3.95 3.82 3.98ESEER 4.03 4.26 3.95 3.90 4.54 4.33 4.08 4.51 4.40 4.61 4.33 4.37Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLNo. Compressors N. 1 1 1 1 1 1 1 1 1 1 1 1Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410APlant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ce Ce Ce CeSource side pump type (6) Ci Ci Ci Ce Ci Ci Ce Ce Ce Ce Ce CeElectrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50Start-up current A 26 37 44 59 35 48 64 75 95 111 118 140Sound power (7) dB(A) 52 53 53 58 52 52 58 59 66 66 70 70Sound pressure level (8) dB(A) 38 39 39 44 38 38 44 45 51 51 55 55D mm 680 680 680 680 680 680 680 680 680 680 680 680H mm 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105W mm 845 845 845 845 845 845 845 845 845 845 845 845Operational weight kg 188 190 195 210 190 195 210 225 240 245 250 270

WWR MTD2 0011ms 0025ms 0031ms 0041ms 0025t 0031t 0041t 0061t 0071t 0091t 0101t 0121t

Nominal Heating power (1) kW 7.20 9.70 12.1 15.3 9.80 12.1 15.9 21.1 26.2 30.5 35 43.8Total absorbed power (2) kW 1.40 1.81 2.30 2.88 1.73 2.17 2.90 3.70 4.60 5.20 6 7.60COP Eurovent 5.14 5.36 5.26 5.31 5.66 5.58 5.48 5.70 5.70 5.87 5.83 5,76Cooling capacity (3) kW 7.10 9.80 12 15.1 9.50 12 15.7 21.3 26.9 30.7 34.8 44.8Total absorbed power (2) kW 1.60 1.96 2.53 3.27 1.80 2.50 3.30 4.10 5.20 6 7 8.80EER Eurovent 4.44 5 4.74 4.62 5.28 4.80 4.76 5.20 5.17 5.12 4.97 5.09Heating capacity (4) 6.80 9.20 11.6 14.6 9.20 11.4 15.3 20 24.8 28.8 33 41.7Total absorbed power (2) kW 1.70 2.30 3 3.60 2.20 2.70 3.70 4.60 5.80 6.40 7.60 9.50COP Eurovent 4 4 3.87 4.06 4.18 4.22 4.14 4.35 4.28 4.50 4.34 4.39Cooling capacity (5) kW 5.20 7.20 8.80 11.3 7.30 8.90 11.8 15.7 19.8 22.9 26 33.4Total absorbed power (2) kW 1.53 2 2.60 3.20 1.90 2.40 3.20 4 5.10 5.80 6.80 8.39EER Eurovent 3.40 3.60 3.38 3.53 3.84 3.71 3.70 3.93 3.88 3.95 3.82 3.98ESEER 4.03 4.26 3.95 3.90 4.54 4.33 4.08 4.51 4.40 4.61 4.33 4.37Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLNo. Compressors N. 1 1 1 1 1 1 1 1 1 1 1 1Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410APlant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ce Ce Ce CeElectrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50Start-up current A 26 37 44 59 35 48 64 75 95 111 118 140Sound power (7) dB(A) 52 53 53 58 52 52 58 59 66 66 70 70Sound pressure level (8) dB(A) 38 39 39 44 38 38 44 45 51 51 55 55D mm 680 680 680 680 680 680 680 680 680 680 680 680H mm 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105W mm 845 845 845 845 845 845 845 845 845 845 845 845Operational weight kg 188 190 195 210 190 195 210 225 240 245 250 270

Note: BWR MTD21. Condenser water in-out 30/35°C (plant side), Evaporator water in-out 0/-3°C (source side)2. According to Eurovent3. Evaporator water in-out 23/18°C (plant side), Condenser water in-out 30/35°C (source side)4. Condenser water in-out 40/45°C (plant side), Evaporator water in-out 0/-3°C (source side)5. Evaporator water in-out 12/7°C (plant side), Condenser water in-out 30/35°C (source side)6. Ci=Circulator; Ce=Centrifugal7. Sound power level according to ISO 9614 and Eurovent 8/18. Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside

dimensions of the unit.*According to the Eurovent standard without circulation pump input power.

Note: WWR MTD21. Evaporator water (in/out) = 12/7°C, condenser water

(in/out) = 30/35°C, based on Eurovent Standard2. Evaporator water (in/out), 10/5°C, condenser water

(in/out) 40/45°C, based on Eurovent standard3. Sound pressure measured at 1 m in open field conditions

Main Components

• Housing and base are made from hot-galvanized epoxy powder coated sheet metal• Case panels are insulated within low noise material for further improvement of

silence• Hermetic scroll compressors with oil sump heater and electronic overheating

protection with centralised manual reset• The water circuit is complete with:

- variable flow water pump (system side) & variable flow source pump- source side modulating valve for models WWR (water source units), this will switch off the water flow whenever the compressor is not in operation.

- differential pressure switch on source side and system side- expansion vessel (Heat Pump circuit only)- safety valve- manual filling assembly

- pressure gauge- manual air vent valve

• Heat exchangers on the system and source side are brazed plate models in AISI 316 stainless steel providing high efficiency and a low pressure drop, complete with vapour barrier closed-cell heat insulation

• Soft start for 230V/1/50Hz (45 amps)• The electronic menu allows control of:

- plant and Geothermal ground circuits (BWR) / modulating valve (WWR)- domestic hot water production by control of an external three-way valve (Y Plan)- a zone of direct heating- external heating source- weather compensation (sensor is accessory)

NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your distributor for details.

DW

H

29

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided withinthe product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.

Page 82: HQ Brochure

BWR DHW2

WITH HEAT RECOVERY

Unit Description

The DeLonghi Professional BWR DHW2 are a unique range of commercialground or water source heat pumps which are capable of providing a highefficiency combination of output conditions:

• Heating only• Simultaneous heating and hot water to 55ºC. • Hot water only• Cooling only• Simultaneous cooling and hot water with up to 100% heat recovery• Simultaneous cooling and heating with up to 100% heat recovery

• These units can be specified to suit a particular application and due to theirability to provide two simultaneous outputs they are able to provide real benefits on both residential and commercial applications.

• Within the commercial sector these heat pumps provide flexibility and realenvironmental benefits. As an alternative to conventional VRF systems these units remove all of the refrigerant from within a building and therefore significantly remove the potential for refrigerant leakage therefore complying completely with the objectives of the F Gas regulations.

• Also when operating on a split heating/hot water and air conditioning loadthese heat pumps will provide up to 100% heat recovery which then benefits the user with free heating or hot water.

• A growing demand for energy and heat recovery has created a highly efficient requirement to use these units to recover waste energy from wastewater or fluid flows, recovering energy from cooling towers or waste waterflows is easily achievable when utilising these units in heat recovery specification.

• Also these heat pump units will provide up to 100% duty on either primaryor secondary heat exchangers along with the ability to provide a combination of load capability heating and hot water simultaneously or heating and cooling simultaneously with up to 100% heat recovery. This allows the heat pump units to provide this simultaneous output feature to manage seasonal heating and cooling loads from the same heat pump unit.

• These DeLonghi Professional units are high specification heat pumps whichare built to exacting standards with regard to efficiency and functionality. Allthe units are European manufactured and benefit from the DeLonghi Professional approach to product development and quality management providing the complete package that would be expected from a premier manufacturer.

Unit Summary

BWR DHW2 UNITS: WW/WWR & BW/BWR

CAPACITY: 5kW-40kW

POWER SUPPLY: Single Phase & Three Phase models

These units provide simultaneous supplies of domestic hot waterand heating/air conditioning.

HIGH EFFICIENCY & PERFORMANCE:

COP 3.56 (356% efficient)BWR DHW2 source flow temperature 0ºC/-3ºC & output flow temp 35ºC*

COP 4.57 (457% efficient)WWR DHW2 source flow temperature 5ºC/10ºC & output flow temp 35ºC*

*Average COP for the BWR & WWR DHW2 ranges

NOTE. Actual system efficiency (COP) and annual performance will depend on thedistribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installedin order to provide efficient operational performance.

FEATURES & OPERATIONAL BENEFITS:• Fully self-contained unit – no external refrigerant pipes• Incorporates source and circulation pumps as standard• Highly efficient and flexible design with easy to use controls• Heating, cooling and domestic hot water provided• Suitable for large capacity hot water users and simultaneous

heating & air conditioning applications*(COP is shown without circulation pump input power. Please note that unlike most other heatpumps these units incorporate built in circulation pumps, therefore by not including the circulationpump input power we are able to provide a direct performance comparison with other units).

Note:

30

HEATINGHEATINGHEATING COOLINGCOOLINGCOOLING HOT WATERHOT WATERHOT WATERHEATING +HEATING +HOT WATERHOT WATERHEATING +HOT WATER

COOLING +COOLING +HOT WATERHOT WATERCOOLING +HOT WATER

1. Heating mode: Plant side inlet water temperature at 30°C and outlet at 35°C, Source side inlet water temperature at 10°C and outlet at 5°C

2. Operation recovery plant side inlet water temperature at 45°C and outlet at 50°C, Source side inlet water temperature at 10°C and outlet at 5°C

3. Cooling mode: Plant side inlet water temperature at 23°C and outlet at 18°C, Source side inlet water temperature at 30°C and outlet at 35°C

4. Cooling mode: Plant side inlet water temperature at 12°C and outlet at 7°C, Source side inlet water temperature at 30°C and outlet at 35°C

5. Heating mode: Plant side inlet water temperature at 30°C and outlet at 35°C, Source side inlet water temperature at 0°C and outlet at -3°C (Gly 25%)

6. Funzionamento in recupero: Plant side inlet water temperature at 45°C and outlet at 50°C, Source side inlet water temperature at 0°C and outlet at -3°C (Gly 25%)

7. Standard unit data - DHW/S model with soft starter for 230V/1/50Hz

8. Sound pressure at 1 meter distance from the external surface of the unit, free field.

*According to the Eurovent standard without circulation pump input power.

AXIAL

DW

H

Page 83: HQ Brochure

BWR DHW2 Ground Source & Geothermal Heat Pumps

Main Components

• Housing and base are made from hot-galvanized epoxy powder coated sheet metal

• Case panels are insulated within low noise material for noise reduction

• Hermetic scroll type compressors, equipped with the crankcase heater and thermalprotection

• Primary stainless steel (AISI 316) plate heat exchanger with high efficiency and low pressure drop (providing domestic hot water or heating)

• When combined with the secondary heat exchanger (cooling duty) these units will provide either full or partial heat recovery

• High efficiency and low pressure drop stainless steel (AISI 316) source side plateheat exchanger for efficient heat transfer and maximum performance.

• Soft start for 230V/1/50Hz units - WWR BWR DHW/S

• The water circuit comes complete with:

- Primary heat exchanger circulation pump for domestic hot water or heating circuit

- Secondary heat exchanger circulation pump for heating or cooling circuit

- Ground source/Geothermal pump for the BWR model

- differential pressure switch on source side and system side

- expansion vessel (Heat Pump circuit only)

- safety valve (6 bar)

- manual filling assembly

- pressure gauge

- venting and draining valve

NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your distributor for details.packs, see current price list orcontact ICS HPT or your distributor for details.

31

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided withinthe product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.

BWR DHW2 0011ms 0025ms 0031ms 0041ms 0025t 0031t 0041t 0061t 0071t 0091t 0101t 0121t

Nominal Heating power (1) kW 5.40 7.30 9.20 11.7 7.50 9.10 12.2 16 19.8 23 26.5 33.3Total absorbed power (2) kW 1.34 1.82 2.35 2.80 1.74 2.10 2.80 3.50 4.40 4.90 5.80 7.30COP Eurovent 4.03 4 3.92 4.18 4.31 4.33 4.36 4.57 4.50 4.69 4.57 4.56Cooling capacity (3) kW 7.10 9.80 12 15.1 9.50 12 15.7 21.3 26.9 30.7 34.8 44.8Total absorbed power (2) kW 1.60 1.96 2.53 3.27 1.84 2.50 3.30 4.10 5.15 5.95 7 8.80EER Eurovent 4.44 5 4.74 4.62 5.16 4.80 4.76 5.20 5.22 5.16 4.97 5.09Heating capacity (4) 5.20 7.10 9 11.3 7 8.70 11.8 15.2 18.8 21.8 25.1 31.9Total absorbed power (2) kW 1.70 2.30 3 3.60 2.20 2.70 3.70 4.40 5.60 6.20 7.40 9COP Eurovent 3.06 3.09 3 3.14 3.18 3.22 3.19 3.45 3.36 3.52 3.39 3.54Cooling capacity (5) kW 5.20 7.20 8.80 11.3 7.30 8.90 11.8 1 5.7 19.8 22.9 26 33.4Total absorbed power (2) kW 1.53 2 2.60 3.20 1.90 2.41 3.19 4 5.10 5.80 6.80 8.40EER Eurovent 3.40 3.60 3.38 3.53 3.84 3.69 3.70 3.93 3.88 3.95 3.82 3.98ESEER 4.03 4.26 3.95 3.90 4.54 4.33 4.08 4.51 4.40 4.61 4.33 4.37Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLNo. Compressors N. 1 1 1 1 1 1 1 1 1 1 1 1Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410APlant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ce Ce Ce CeSource side pump type (6) Ci Ci Ci Ce Ci Ci Ce Ce Ce Ce Ce CeElectrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50Start-up current A 26 37 44 59 35 48 64 75 95 111 118 140Sound power (7) dB(A) 52 53 53 58 52 52 58 59 66 66 70 70Sound pressure level (8) dB(A) 38 39 39 44 38 38 44 45 51 51 55 55D mm 680 680 680 680 680 680 680 680 680 680 680 680H mm 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105W mm 845 845 845 845 845 845 845 845 845 845 845 845Operational weight kg 188 190 195 210 190 195 210 225 240 245 250 270

WWR MTD2 0011ms 0025ms 0031ms 0041ms 0025t 0031t 0041t 0061t 0071t 0091t 0101t 0121t

Nominal Heating power (1) kW 7.20 9.70 12.1 15.3 9.80 12.1 15.9 21.1 26.2 30.5 35 43.8Total absorbed power (2) kW 1.40 1.81 2.30 2.88 1.73 2.17 2.90 3.70 4.60 5.20 6 7.60COP Eurovent 5.14 5.36 5.26 5.31 5.66 5.58 5.48 5.70 5.70 5.87 5.83 5.76Cooling capacity (3) kW 7.10 9.80 12 15.1 9.50 12 15.7 21.3 26.9 30.7 34.8 44.8Total absorbed power (2) kW 1.60 1.96 2.53 3.27 1.80 2.50 3.30 4.10 5.20 6 7 8.80EER Eurovent 4.44 5 4.74 4.62 5.28 4.80 4.76 5.20 5.17 5.12 4.97 5.09Heating capacity (4) 6.80 9.20 11.6 14.6 9.20 11.4 15.3 20 24.8 28.8 33 41.7Total absorbed power (2) kW 1.70 2.30 3 3.60 2.20 2.70 3.70 4.60 5.80 6.40 7.60 9.50COP Eurovent 4 4 3.87 4.06 4.18 4.22 4.14 4.35 4.28 4.50 4.34 4.39Cooling capacity (5) kW 5.20 7.20 8.80 11.3 7.30 8.90 11.8 15.7 19.8 22.9 26 33.4Total absorbed power (2) kW 1.53 2 2.60 3.20 1.90 2.40 3.20 4 5.10 5.80 6.80 8.39EER Eurovent 3.40 3.60 3.38 3.53 3.84 3.71 3.70 3.93 3.88 3.95 3.82 3.98ESEER 4.03 4.26 3.95 3.90 4.54 4.33 4.08 4.51 4.40 4.61 4.33 4.37Compressor type SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLLNo. Compressors N. 1 1 1 1 1 1 1 1 1 1 1 1Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410APlant side pump type (6) Ci Ci Ci Ci Ci Ci Ci Ci Ce Ce Ce CeElectrical power supply V-Ph~Hz 230-1~50 230-1~50 230-1~50 230-1~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50 400-3N~50Start-up current A 26 37 44 59 35 48 64 75 95 111 118 140Sound power (7) dB(A) 52 53 53 58 52 52 58 59 66 66 70 70Sound pressure level (8) dB(A) 38 39 39 44 38 38 44 45 51 51 55 55D mm 680 680 680 680 680 680 680 680 680 680 680 680H mm 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105W mm 845 845 845 845 845 845 845 845 845 845 845 845Operational weight kg 188 190 195 210 190 195 210 225 240 245 250 270

Page 84: HQ Brochure

Prana BWR-MTD

REVERSIBLE HEAT PUMP FOR INDOOR INSTALLATION 40KW - 360KW

Unit Description

• Optimised internally positioned heat pump unit with optional chilled water production, a complete range is available from 40kW-360kW operating through varying source temperature ranges to facilitate either ground source or water source operation.

• The range includes single-circuit/two-compressor versions and also twincircuit/four compressor versions for larger output capacity. This configuration provides excellent load management capability which giveshigh performance and efficiency along with associated contingency benefits and redundancy.

• The use of R410A enables the unit to operate with high efficiency and performance whilst remaining flexible in operation.

• DeLonghi Professional has designed the Prana BWR MTD 0152-1204 unitsto be configured with a range of optional accessories for ease of operationwhen specified across a range of differing applications from ground watersource to higher temperature heat recovery from process or production waste water.

• The built-in hydronic module includes the main water circuit components;it is available in various configurations with one or two pumps with highor low head both on the evaporator and the condenser side. The PRANABWR dimensions and sizes provided within this guide are shown withoutany hydronic pump set options, these options may increase the size of the unit. Please contact ICS specification support for the final specification& dimensions of any unit selected with the hydronic pack.

• The W3000 controller provides integrated single unit control but also allows parallel operation of up to 5 units of varying capacity. This allowsa completely bespoke system to be configured to match the demands of larger applications.

• The Prana BWR range is also able to connect either singularly or a multiunit modular basis with ModBus/Echelon/Bacnet protocol cards for BMS compatability

• These DeLonghi Professional units are high specification heat pumps which are built to exacting standards with regard to efficiency and functionality. All the units are European manufactured and benefit fromthe DeLonghi Professional approach to product development and qualitymanagement providing the complete package that would be expected from a premier manufacturer.

• The Prana HT range is designed for modular application to accommodatelarger capacity requirements***.

32

COOLINGCOOLINGCOOLINGHEATINGHEATINGHEATING HOT WATERHOT WATERHOT WATER MODULARMODULARMODULAR

W3000The W3000 controller offers the latest control and operatingfunctions developed directly by DeLonghi Professional utilisingtheir experience gained within the field of heat pump design andrelated plant engineering. The keypad is generously sized with afull operating status display, the controls and detailed LCD makeaccess to machine settings easy and safe. Temperature regulation with a proportional logiccapability is related to the return water temperature which provides the ability to satisfysimultaneously heating, sanitary hot water and cooling requests with no need for modechangeover. The diagnostics include full management of alarms with black box function and analarm recorder for analysis of unit performance. Monitoring is achieved through either DeLonghiProfessional devices or with various options for interfacing to ModBus, Bacnet or Echelon &LonTalk protocols. The controller has the compatibility to operate with a remote keyboard (singlecontroller management of up to 10 modular units) along with a full time clock function forefficient programming of operation (standard 4 days and 10 time bands). Exclusive self-adaptivedefrost logic, monitoring multiple operational- and ambient parameters are incorporated whichallow the unit to reduce the number and duration of the defrost cycles with the benefit ofincreased overall energy efficiency.

***modular capability

Unit Summary

PRANA BWR MTD UNITS: WW/WWR & BW/BWR CAPACITY: 40kW-360kWPOWER SUPPLY: Three Phase models

These units provide a heating output to 55°C with the option toalso provide cooling with a reversible configuration.

HIGH EFFICIENCY & PERFORMANCE:

COP 4.1 (410% efficient)**BWR MTD source flow temperature 0ºC/-3ºC & output flow temp 35ºC

COP 5.06 (506% efficient)**WWR MTD source flow temperature 5ºC/10ºC & output flow temp 35ºC

*Average COP for the Prana BWR & WWR MTD ranges

NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiitersystem utilised. Care should be taken to ensure that the heat pump is installed in order to provideefficient operational performance.

FEATURES & OPERATIONAL BENEFITS:

•Full DHW and heating control•Heating only or reversible heat pump•Built in plant and circulation pump•High value and high performance•55ºC output temperature•Modular control for multiple unit configuration•Compact footprint for plant room positioning

Certificate Number MSC HP0005Heat Pumps

Microgeneration scheme accreditation allows access to grant funding and also guarantees performance and manufacturing quality.

Page 85: HQ Brochure

Prana BWR-MTD Ground Source & Geothermal Heat Pumps

BWR-MTD 0152 0182 0202 0252 0262 0302 0352 0412 0452 0512

Cooling capacity (1) kW 43.4 50.1 58.9 66.4 72.6 86.7 101 115 129 144

Total power input (1) kW 10.0 11.3 13.0 15.2 16.6 19.5 22.7 25.9 28.9 32.2

Condenser heating capacity (1) 5.8 60.7 71.2 80.7 88.2 105 123 139 156 174

EER 4.34 4.43 4.53 4.37 4.37 4.45 4.46 4.43 4.45 4.46

ESEER 5.80 6.00 6.00 5.70 5.60 5.70 5.80 5.70 5.80 5.80

Heating capacity (2) kW 50.5 58.2 68.0 77.0 85.0 101 117 132 148 165

Total power input (2) kW 12.9 14.3 16.7 19.2 21.1 24.7 28.7 32.2 36.0 40.0

COP (2) 3.91 4.07 4.07 4.01 4.03 4.09 4.07 4.10 4.12 4.14

No. Compressors/No. Circuits N. 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1 2/1

Sound power (3) dB(A) 73 74 74 74 75 76 77 77 78 78

Sound pressure (4) dB(A)

Length (5) mm 1055 1055 1055 1055 1055 1222 1222 1222 1222 1222

Width (5) mm 649 649 649 649 649 843 843 843 843 843

Height (5) mm 1255 1255 1255 1255 1255 1496 1496 1496 1496 1496

Operating weight (5) kg 290 305 315 325 330 585 605 660 685 740

BWR-MTD 0552 0612 0604 0704 0804 0904 1004 1104 1204

Cooling capacity (1) kW 165 186 174 203 228 258 288 329 371

Total power input (1) kW 36.9 41.6 38.9 45.2 51.6 58.0 64.0 74.0 83.5

Condenser heating capacity (1) 200 225 211 245 276 312 348 398 450

EER 4.47 4.48 4.47 4.48 4.42 4.45 4.50 4.44 4.44

ESEER 5.90 5.80 5.80 5.90 5.80 5.90 5.90 6.00 5.90

Heating capacity (2) kW 190 215 202 234 263 297 332 379 428

Total power input (2) kW 45.9 51.8 49.2 56.6 64.1 72.1 79.5 91.9 104

COP (2) 4.14 4.14 4.11 4.13 4.10 4.12 4.17 4.13 4.12

No. Compressors/No. Circuits N. 2/1 2/1 4/2 4/2 4/2 4/2 4/2 4/2 4/2

Sound power (3) dB(A) 79 79 86 87 88 89 90 91 91

Sound pressure (4) dB(A)

Length (5) mm 1222 1222 2227 2227 2227 2227 2227 2227 2227

Width (5) mm 873 873 877 877 877 877 877 877 877

Height (5) mm 1496 1496 1780 1780 1780 1780 1780 1780 1780

Operating weight (5) kg 790 830 1090 1165 1245 1290 1395 1500 1585

The PRANA BWR dimensions and sizes provided within this guide are shown without any hydronic pump set options, these options may increase the sizeof the unit. Please contact ICS specification support for the final specification & dimensions of any unit selected with the hydronic pack.

Note:

1. Evaporator water (in/out) = 12/7°C, condenser water (in/out) = 30/35°C, based on Eurovent Standard.

2. Evaporator water (in/out) = 12/7°C; Condenser water (in/out) = 40/45°C.

3. Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

4. Sound pressure in open field conditions on reflecting surface (directivity factor Q=2), average value on longest side, at 1 m from the outer surface and at 1 m height in relation to the unit supporting base.

5. Unit in standard configuration/execution, without optional accessories.L W

D

33

MODULARMODULARMODULAR

MODULAR CAPABILITY

The Prana BWR MTD range is designed for modular application to accommodate multi unit larger capacity requirements***.

AXIAL

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with orwithout prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification andequipment details at point of quotation and/or order.

Page 86: HQ Brochure

Prana BWR DHW & TR

REVERSIBLE HEAT PUMP WITH TOTAL HEAT RECOVERY40KW - 360KW

Unit Description

The DeLonghi Prana BWR DHW & TR are a unique range of commercial groundor water source heat pumps which are capable of providing a high efficiencycombination of output conditions:

• Heating only• Simultaneous heating and hot water to 55ºC. • Hot water only• Cooling only• Simultaneous cooling and hot water with up to 100% heat recovery• Simultaneous cooling and heating with up to 100% heat recovery

• The range is very similar to the Prana BWR MTD in terms of features and control however the range allows these four pipe units to be applied on awider range of applications.

• The range includes single-circuit/two-compressor versions and also twincircuit/four compressor versions for larger output capacity. This configuration provides excellent load management capability which giveshigh performance and efficiency along with associated contingency benefits and redundancy.

• These fully optimised water source heat pumps provide partial or total heat recovery for the simultaneous production of chilled/hot water withhermetic rotary scroll compressors operating with R410A, plate heat exchangers and thermostatically controlled expansion valve.

• Also these heat pump units will provide up to 100% duty on either primaryor secondary heat exchangers along with the ability to provide a combination of load capability heating and hot water simultaneously or heating and cooling simultaneously with up to 100% heat recovery. This allows the heat pump units to provide this simultaneous output feature tomanage seasonal heating and cooling loads from the same heat pump unit.

• Energy saving is achieved by the W3000 advanced control logic. The mostefficient operational mode is set completely automatically and independently by the units controller, in order to minimize the absorbed energy whatever the cooling and/or heating demand might be.

34

MODULARMODULARMODULARHOT WATERHOT WATERHOT WATERCOOLINGCOOLINGCOOLINGHEATINGHEATINGHEATING

***modular capability

W3000The W3000 controller offers the latest control and operatingfunctions developed directly by DeLonghi Professional utilising theirexperience gained within the field of heat pump design and relatedplant engineering. The keypad is generously sized with a fulloperating status display, the controls and detailed LCD make accessto machine settings easy and safe. Temperature regulation with a proportional logic capability isrelated to the return water temperature which provides the ability to satisfy simultaneouslyheating, sanitary hot water and cooling requests with no need for mode changeover. Thediagnostics include full management of alarms with black box function and an alarm recorder foranalysis of unit performance. Monitoring is achieved through either DeLonghi Professional devicesor with various options for interfacing to ModBus, Bacnet or Echelon & LonTalk protocols. Thecontroller has the compatibility to operate with a remote keyboard (single controller managementof up to 10 modular units) along with a full time clock function for efficient programming ofoperation (standard 4 days and 10 time bands). Exclusive self-adaptive defrost logic, monitoringmultiple operational- and ambient parameters are incorporated which allow the unit to reduce thenumber and duration of the defrost cycles with the benefit of increased overall energy efficiency.

Unit Summary

PRANA BWR DHW & TR UNITS: WW/WWR & BW/BWR

CAPACITY: 40kW-360kW

POWER SUPPLY: Three Phase models

These units provide simultaneous supplies of domestic hot waterand heating/air conditioning.

HIGH EFFICIENCY & PERFORMANCE:

COP 4.1 (410% efficient)**BWR DHW & TR source flow temperature 0ºC/-3ºC & output flow temp 35ºC

COP 5.06 (506% efficient)**WWR DHW source flow temperature 5ºC/10ºC & output flow temp 35ºC*Average COP for the BWR DHW & TR & WWR MTD ranges

NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiitersystem utilised. Care should be taken to ensure that the heat pump is installed in order to provideefficient operational performance.

FEATURES & OPERATIONAL BENEFITS:

• Full DHW and heating control• Simultaneous heating and cooling outputs• Heating only or reversible heat pump• 100% heat recovery capability• Suitable for a 4 pipe distribution system• 55ºC output temperature• Modular control for multiple unit configuration• Compact footprint for plant room positioning

TOTAL RECOVERY VERSION - BWR TR• 6 pipe system• Simultaneous heating & cooling• 100% water to water heat recovery• Manage any percentage of heating orcooling load

• Year round maximum performance• No external controls required• 100% energy efficiency• Maximise ground collector energy• Total system control

Completely flexible heating & cooling geothermal “solution in a box”

Page 87: HQ Brochure

Prana BWR DHW & TR Ground Source & Geothermal Heat Pumps

BWR-DHW 0152 0182 0202 0252 0262 0302 0412 0512 0612Specification & performance shown belowis for BWR DHW versions (TR also available)

Cooling capacity (1) kW 48.6 55.8 65 73.8 83.2 97.5 127 159 206Total power input (1) kW 8.70 9.80 11.3 13.2 14.7 17.4 22.7 28.1 36.5EER 5.59 5.69 5.75 5.59 5.66 5.60 5.59 5.64 5.63ESEER * * * * * * * * *Heating capacity (2) kW 52.1 59.7 69.3 79 88.9 104 135 169 219Total power input (2) kW 12.4 13.8 16.2 18.5 20.4 23.9 31 38.4 49.9COP 4.20 4.33 4.28 4.28 4.36 4.37 4.35 4.40 4.38Cooling capacity (3) kW 40.4 46.7 54.1 61.7 67.9 82 106 133 172Total power input (3) kW 12.4 13.8 16.2 18.5 20.4 23.9 31 38.4 49.9Heat recovery capacity (3) kW 52.1 59.7 69.3 79 88.9 104 135 169 219No. Compressors/No. Circuits N. 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2Total power input kWSound power (4) dB(A) 73 74 74 74 75 76 77 78 79Sound pressure (5) dB(A) 42 43 43 43 44 45 46 47 48Length (6) mm 1222 1222 1222 1222 1222 1222 1222 1222 1222Width (6) mm 893 893 893 893 893 893 893 893 893Height (6) mm 1496 1496 1496 1496 1496 1496 1496 1496 1496Operating weight (6) kg 450 470 490 505 525 550 745 825 910

BWR-DHW 0604 0704 0804 0904 1004 1104 1204 1404 1604Specification & performance shown belowis for BWR DHW versions (TR also available)

Cooling capacity (1) kW 194 225 255 285 317 365 413 468 522Total power input (1) kW 34.8 40 45.3 50.8 56.3 64.8 73 84.1 95.1EER 5.58 5.63 5.62 5.61 5.63 5.63 5.66 5.56 5.49ESEER * * * * * * * * *Heating capacity (2) kW 208 240 270 303 338 388 440 498 557Total power input (2) kW 47.7 54.7 61.8 69.2 76.8 88.4 99.6 113 126COP 4.36 4.38 4.37 4.38 4.40 4.39 4.41 4.41 4.42Cooling capacity (3) kW 163 188 212 238 266 305 346 392 438Total power input (3) kW 47.7 54.7 61.8 69.2 76.8 88.4 99.6 113 126Heat recovery capacity (3) kW 208 240 270 303 338 388 440 498 557No. Compressors/No. Circuits N. 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2 4/2Total power input kWSound power (4) dB(A) 86 87 88 89 90 91 91 91 91Sound pressure (5) dB(A) 54 55 56 57 58 59 59 59 59Length (6) mm 2520 2520 2520 2520 2520 2520 2520 2520 2520Width (6) mm 880 880 880 880 880 880 880 880 880Height (6) mm 1810 1810 1810 1810 1810 1810 1810 1810 1810Operating weight (6) kg 975 1165 1365 1445 1610 1710 1810 1895 2000

Note:

1. Evaporator water (in/out) = 12/7°C; condenser water (in/out) = 14/30°C

2. Condenser water (in/out) = 40/45°C; evaporator water (in/out) = 14/7°C

3. Evaporator water (in/out) = 12/7°C; Recovery unit water (in/out) = 40/45°C

4. Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.

5. Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.

6. Unit in standard configuration/execution, without optional accessories.

L W

D

35

MODULARMODULARMODULAR

MODULAR CAPABILITY

The Prana BWR DHW & TR range is designed for modular application to accommodate multi unit larger capacity requirements***.

AXIAL

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with orwithout prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification andequipment details at point of quotation and/or order.

The PRANA BWR dimensions and sizes provided within this guide are shown without any hydronic pump set options, these options may increase the sizeof the unit. Please contact ICS specification support for the final specification & dimensions of any unit selected with the hydronic pack.

Page 88: HQ Brochure

Buffer Tanks36

Buffer Tanks (Stainless) 90L 120L 210L 300L 400L

Capacity litres 90 120 210 300 TBA

Height mm 732 920 1483 2020 TBA

Diameter mm 550 550 550 550 TBA

Weight (empty) kg 13 18 28 37 TBA

Weight (full) kg 103 138 238 337 TBA

Standing losses kWhr/24hr 0.80 1.00 1.60 1.93 TBA

Maximum working pressure - cylinder bar 3.5 3.5 3.5 3.5 TBA

Maximum working pressure - space heating bar 3.5 3.5 3.5 3.5 TBA

Input connections heat pump x2 mm 28 28 35 35 TBA

Output connections heat pump x2 mm 28 28 35 35 TBA

Heat pump input connection tapping height mm 464 652 1215 1752 TBA

Heat pump output connection tapping height mm 295 295 295 295 TBA

Input connections heating x2 mm 28 28 35 35 TBA

Output connections heating x2 mm 28 28 35 35 TBA

Heating input connection tapping height mm 295 295 295 295 TBA

Heating output connection tapping height mm 464 652 1215 1752 TBA

Immersion Boss inch 1.75 1.75 1.75 1.75 TBA

Drain connection inch 0.5 0.5 0.5 0.5 TBA

Drain connection tapping height mm 220 220 220 220 TBA

Fill connection mm 22 22 22 22 TBA

Buffer Tanks (Carbon Steel) 100 - 2000 litres capacity

Best practice standards require a buffer tank to be incorporated within any heat pump system. The buffer tank provides thermalmass and inertia to the system whilst providing a thermal buffer during the heat pumps defrost cycle.

The buffer tank also provides an efficient means of incorporating any number of heat pumps or distribution circuits within a single systemi.e. a standard multi tap buffer allows for 2 x heat pumps and 2 x output circuits to be easily connected.

• Provide adequate thermal mass

• Ensure system volume is maintained at all times (regardless of any zone control)

• Provides thermal inertia during the defrost cycle

The buffer tank also provides a thermal break between the heat pump and the distribution system, this allows both sides of the system(heat pump and property) to operate at the optimum temperature difference in order to achieve maximum efficiency. A heat pump willrequire a narrow temperature difference (typically 5ºC to 6ºC) where as the distribution system may require a wider temperature differencei.e. when specifying a retrofit installation or similar.

Example: 210 Litre

Buffer vessels are a high quality duplex stainless steel tank that contains a volume of water as perthe specification table shown above.

The Buffer store is insulated to a very high standard using high density HCFC free foam cased in asteel shell and therefore has an ozone deletion potential (ODP) of zero and a global warmingpotential (GWP) of 1.

ICS HPT also provide a range of carbon steel buffer tanks up to 2000 litres in capacity. Please contacttechnical sales support for details.

Page 89: HQ Brochure

DHW Cylinders37

Stainless Heat Pump Optimised DHW is a range of unvented hot water storage cylinders, manufactured in the latest high quality duplexstainless steel. They are designed to provide mains pressure hot water and are supplied as a package which complies with Section G3of the Building Regulations. The appliance is extremely well insulated using high density HCFC free foam insulation with an ozonedepleting potential (ODP) of zero and a global warming potential (GWP) of 1. It is fitted with all necessary safety devices and suppliedwith all the necessary control devices to make installation on site as easy as possible.

STAINLESS HEAT PUMP OPTIMISED (HP)

The Stainless Heat Pump Optimised DHW is an unvented hot water storage cylinder fitted with two high efficiency internal primary heat exchangersespecially designed for use with heat pump systems. These two heat exchangers can be connected in parallel to the heat pump circuit when a solarthermal system is not installed. When both heat pump and solar thermal systems are installed, the top heat exchanger is connected to the heat pumpcircuit and the bottom heat exchanger is connected to the solar circuit a shown below. All Stainless Heat Pump Optimised DHW models are fitted with3kW (230Vac, 50Hz) immersion heater for raising the temperature of the stored water to about 60ºC after the heat pump heating cycle if necessary.

NOTES1. Not all models - see table 1

2. Recovery times based on Primary Coil/L.H Duty (i.e. assumes the boiler output is adequate)

3. All connections are supplied with compression fittings for direct connection to copper pipework

DHW Cylinders (Stainless) HP180IND HP210IND HP250IND HP300IND HP400IND

Capacity - total volume litres 180 210 250 300 400Volume heated by IH litres 113 135 160 195 270Dedicated solar volume litres 65 75 90 105 130Standing heat loss rate kWh/24h 1.40 1.60 1.75 1.93 3.33Weight - empty kg 33 38 43 49 61Weight - full kg 213 248 293 349 461Pressure regulating valve setting bar 2.25 2.25 2.25 2.25 2.25Expansion relief valve setting bar 4.5 4.5 4.5 4.5 4.5Temperature setting (P&T valve) ºC 90 90 90 90 90Pressure setting (P&T valve) bar 6.0 6.0 6.0 6.0 6.0Expansion vessel size (volume) litres 18 24 24 35 2 x 24Expansion vessel initial charge pressure bar 2.25 2.25 2.25 2.25 2.25Height A mm 1295 1483 1733 2020 2040Diameter B mm 550 550 550 550 63022mm secondary return C mm - 1127 1377 1577 159222mm compression cold feed D mm 442 442 522 522 557P & T valve E mm 1053 1241 1491 1777 178422mm solar return - bottom coil F mm 223 223 223 223 23822mm solar fl ow - bottom coil G mm 352 352 472 472 54828mm primary return - top coil H mm 467 542 647 742 64128mm primary fl ow - top coil I mm 1072 1232 1467 1562 1791Dual CT & OHT pocket - 1 top J mm 732 837 962 1092 1076Dual CT & OHT pocket - 2 bottom K mm 419 419 539 539 651Solar sensor pocket - 1 top L mm 882 1000 1180 1367 1382Solar sensor pocket - 2 bottom M mm 203 203 262 262 3343kW immersion heater height N mm 457 522 607 702 640Surface area of solar heater coil m2 0.68 0.68 0.97 0.97 1.27Solar coil thermal rating @ 25 l/s kW - - - - -Solar coil pressure loss @ 25 l/s bar 0.191 0.191 0.241 0.241 0.31Internal heat exchanger surface area m2 1.36 1.56 1.94 1.94 2.72Internal heat exchanger pressure bar 0.356 0.382 0.457 0.457loss series @ 25 l/s

IMPORTANT NOTES:1. All Stainless Lite HP models are suitable for both open vented and sealed

primary systems.2. Stainless Lite HP models must not be used with solid fuel boilers or steam as the heat source.3. Heat pumps will heat the domestic hot water to between 45ºC - 55ºC, therefore provision should be

made to periodically heat the cylinder to about 65ºC to prevent growth of legionella.

Sanitary hot water cylinders/stores 1000 - 5000 litres capacity

ICS HPT also provide a range of sanitary hot water cylinders/stores for commercial use up to 5000litres in capacity. Please contact technical sales support for details.

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided withinthe product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.

Page 90: HQ Brochure

Fan Coils - Hydronic38

MHD. HIGH WALL MOUNTED FAN COILS

Hi-wall type terminal 2.15 - 4.70kW

MHD fan coil terminals are the premium high-wall hydronic fan-coil fromDeLonghi Professional. The compact design and quality finish of this modelcoupled with the exclusive elegance soften the visual impact and make theunits ideal for both office residential installations. These units provide all thestandard befits of a high wall fan coil but with the added benefit of a waterbased system, so reducing refrigerant within the building in line with the F-Gasregulations.

CHD. CEILING MOUNTED CASSETTE

Cassette type terminal 2.7-9.3kW

The CHD hydronic fan-coil cassette from DeLonghi Professional is an electro-mechanical unit, available in two versions: For two pipe installation (unit withsingle coil) and for four pipe installation (unit with double coil). A wide range ofsizes and easy installation make them suitable for various types of application.CHD units are registered within the EUROVENT certification programme. These unitsprovide all the standard befits of a ceiling mounted cassette but with the addedbenefit of a water based system, so reducing refrigerant within the building inline with the F-Gas regulations.

• U-2T electromechanical version for 2-pipe system• U-4T electromechanical version for 4-pipe system

ICS Heat Pump Technology provide a complete range of DeLonghi-DeLonghi Professional Fan Coils and internal Air Handling Unitsto complement the Heat Pump range.

This high quality range of Fan Coils and Air Handling Units allows a complete climate control system to be specified which can provideheating, air-conditioning and domestic hot water.

The benefits of these water based cooling and heating systems can be significant, for example the amount of refrigerant within thesystem is reduced and the potential risk of refrigerant leaks is minimised when compared to refrigerant based direct expansion systems.

Also system installation is simplified as no high pressure refrigerant pipework is required within the building as the refrigeration systemis positioned externally within the fully packaged Air Source Heat Pump or within the Ground Source Heat Pump positioned within theplant area.

These fan coils are ideal for use with either heating only or reversible heat pumps providing a very efficient and environmentally consciousheating and/or air-conditioning system. The DeLonghi Professional hydronic fan coil ranges encompass each key fan coil area of application:

1. High wall units2. Ceiling mounted cassettes (2 or 4 pipe)3. Floor/low wall mounted cased units (2 or 4 pipe)4. Ducted systems for residential or commercial specification (2 or 4 pipe)

In addition to the more traditional commercial applications, fan coils are gaining popularity within thecommercial & residential retrofit markets as they are proving an ideal way to provide an increased kWcapacity to existing radiator size restricted applications i.e. a significantly greater kW capacity from acompact controllable unit.

Page 91: HQ Brochure

Wall, Ceiling, Floor Mount & Ducted Fan Coils39

I-LIFE. LOW WALL/FLOOR MOUNTED FAN COILS

High efficiency fan-coil with synchronous motor electronicswitches, with cabinet or built-in version 1.91 - 7.47kW

i-LIFE fan-coils incorporate modulating speed low energy centrifugal fans. This newgeneration of fan-coil guarantees air flow regulation from 0% to 100% and energyconsumption is reduced by more than 50% when compared to a traditional unit.In addition new commands & controls are available which manage all the functionsoffered by this range of high specification terminal units. Retrofit capability allowsthe i-life fan coil to provide an alternative to traditional radiators, offeringsignificantly greater capacity in an extremely compact unit.

• DFI built-in version, front air intake• DFU version with cabinet, front air intake• DLI built-in version, bottom air intake• DLU version with cabinet, bottom air intake

TYPICAL UNIT CONTROLLER – IK UNIT SHOWN(contact technical support for specific controller configuration)

• Configurable control with LCD screen• On-Off - modulating valve-unit• Master/Slave multiple configuration network• Quick installation with two wire connection

HWD. COMMERCIAL WALL/FLOOR MOUNT FAN COILS

High Head free blowing wall or floor mount terminal 16.8 - 29.8kW

As with the HWD HP ducted unit shown above, these wall or floor mounted versionswill provide heating or cooling with the option of flexible installation and positioning.

The units can be provided with either inlet and/or outlet plenum boxes which willallow specification either for new build or retrofit/refurbishment applications.

• Base version• Single or twin coil version• Heating or cooling option• Inlet and outlet plenum boxes available

HWD. COMMERCIAL DUCTED/FREE BLOWING FAN COIL

High head ducted type terminal 16.8 - 29.8kW

The HWD HP belongs to the ducted fan-coil high head range from DeLonghiProfessional. The units allow for vertical or horizontal installation with variableairflow adjustment, the modular configuration allows for ease of installationenabling the unit to adapt to a variety of applications. The unit can be mountedhorizontally or vertically with a variable modular configuration to match thedemands of a particular specification. High pressure fan capability allows theHWD range of terminals to provide the ideal internal air handling unit selectionto operate with a medium or High temperature heat pump.

• Base version• Single or twin coil version• Heating or cooling option• Flexible plenum configuration

IDEALRADIATOR

REPLACEMENT

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided withinthe product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.

Page 92: HQ Brochure

40

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or DeLonghi Professional (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or withoutprior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment detailsat point of quotation and/or order.

Accessories - EcoampEcoamp Modulating In-line Electric Boost Heater

AB

Potential EcoampSystem Configurations

A. HeatingB. DHW

Unit SummaryECOAMP UNITS: Modulating In-line Electric Boost Heater

CAPACITY: 3kW/6kW/9kW variable/controllable output

POWER SUPPLY: Single Phase models

This unique in-line heater provides a variable output to match thedemands of the application. Control is provided by the Ecoamppackaged driver which operates the in-line potable electric heater, theunit is set to the required output temperature and therefore providesthe most efficient supplementary heating system available.

HIGH EFFICIENCY & PERFORMANCE: Infinitely variableoutput

The Ecoamp is the next generation of supplementary boost heatingfor renewable energy systems providing the most efficient andpractical bi-valent heating option to the installer.

FEATURES & OPERATIONAL BENEFITS:• 3kW, 6kW or 9kW capacity in a single unit

• Heating or domestic hot water compatability

• Easy installation

• New build or retrofit

• Variable output to efficiently match demand

• Operates down to 100 watts capacity

• Accurately maintains the required output temperature

HEATINGHEATINGHEATING HOT WATERHOT WATERHOT WATER

Unit Description

This next generation electric heater, overcomes the normalinefficiencies of supplementary heater use:

• Provides the exact kW capacity required• Only provides the energy required to boost the system • Controls on heater output temperature• Activated via a bi-valent control or ambient stat• Ensures that the primary heating source i.e. heat pump or similar,

will maintain operation whilst the Ecoamp provides only the additional capacity required at any time

• Ideal for low ambient support or auxillary boost• Suitable for heating or DHW use• Designed for in-line connection

The Ecoamp has been developed to meet growing industry demand fora controllable low energy supplementary electric heater. Ease of use,practical installation and low running costs means the Ecoamp fulfils allthe requirements of a boost heater for the renewable industry.

Unlike conventional electric heaters, the Ecoamp will maintain adefined output temperature which provides tremendous systembenefits accurately matching the kW capacity required at any pointand maintaining an accurate output temperature.

UNIT SPECIFICATIONPower supply: Single phase (larger three phase units available

through special order).

Minimum flow (heating circuits): 3-kW & 6-kW = 1m3/h

Minimum flow: 9 & 18-kw = 4m3/h

Maximum flow 17m3/h

Minimum flow: DHW applications confined to 6-kw unit 6 litres/min. *see special conditions of operation

Heating Elements: Titanium or Incoloy 825, high MgO compaction.

Flow tubes BS 316 Stainless Steel

ITT controller temp range: 0ºC to 70ºC

Safety thermal cut out: 80°C (manual reset)

Flow switch: Gold tipped reed switch with Titanium fulcrum pin

Seals: Special formula high temperature polymer

Water connections: 1.5” BSP female thread

Working pressure: 4 bar maximum

Test pressure: 7bar

Mounting: Floor or wall mounting

Standards compliance: European Electromagnetic Compatibility directive 89/336/EEC and 93/068/EEC

Harmonised Standards: EN 55014 – EN55104, EN 5501, EN 5502, CEI 801-4, CEI 801-2, CEI 801-3

The European Low Voltage Directive: 72/23/EEC

The Harmonised Standard: EN 60335-2-35

Power Input: 1 Phase

Load: Stainless Steel Flow Tube With Incoloy 825Elements Product Code: 3-kW 13-Amp ITT 3 kw

6-kW 27-Amp ITT 6 kw

9-kW 40-Amp ITT 9 kw

The “Ecoamp” is an in-line water heater, designed to provide the exact amount ofenergy required by measuring the difference between the required watertemperature and the “actual” temperature.

Construction material and “WRAS” certification.

The materials used in the wetted parts of the unit are as follows:-

Flow switch material: “Noryl” (WRAS approval No. 1108519)

Thermocouple sealing ring material: “TPE” (WRAS approval No. 1008535)

End caps/BSP 1 ½” threaded material: “Glass-filled Nylon”(WRAS approval No.0701523)

Metal tube-to-nylon end-joint material: “EPDM” (WRAS approval No. 1003501)

Page 93: HQ Brochure

• Internal application support engineers - specification advice, technical application support and equipment selection

• Field based specification engineers - site survey/application support, client technical meetings and CPD service

• Online specifier hub - 24/7 information availability, secure login, specifier information and technical details

THE COMPLETE SPECIFIER/INSTALLER SUPPORT SERVICE

HEAT PUMP SPECIFICATION AND INSTALLATION MADE EASY, WITH 24/7ON-LINE, SUPPORT AND AN EXTENSIVE IN-HOUSE AND NATIONALAPPLICATION AND TECHNICAL SUPPORT STRUCTURE.

Technical and application support is a critical element of the ICS Heat Pump Technology operation and is an area which is given the highest priority.The dedicated team of heat pump specialists provides both telephone and field base support as required. The majority of questions asked by ICScustomers and partners can be dealt with via our technical support desk which is manned by experienced engineers who have hands on knowledgeof both the equipment and applications. You can be sure that your enquiry or query will be dealt with as a priority until the correct solutions ishighlighted and the situation is dealt with appropriately whether this be a new commercial specification or a technical/application question.

ICS provide the award wining partner hub to all APP registered users. The partner hub provides a complete access point for all application,specification, equipment and associated information on a 24/7 basis. The hub will provide you with many standard technical and sales documentsbut importantly also providing you with application and specification tools to assist you in producing quotations and/or specifications within theresidential and commercial markets. contact us for your unique password and log in details (activated when your APP card is registered).

ENCLOSURES ESSENTIAL COMPONENTS Heat pumps can call for specific application demands interms of either noise or aesthetic requirements. Theseare the applications where ICS Heat Pump Technologycan provide a range of enclosures to match the on-siterequirements relating to the majority of residential andcommercial heat pump applications. These enclosuresystems range from a standard security enclosure to aspecific colour coordinated designed system or a lownoise heat pump acoustic enclosure with a specifiedoutput rating.

In addition to the above ICS HPT are also able to provide a range of ancillary equipment to compliment the heat pump installation/specification. Thisequipment includes the EcoAmp variable Inline Electric Heater which provides an ideal supplementary boost option for low ambient support or tosupplement a single phase heat pump installation.

Please contact technical sales support for details of the EcoAmp heater and the full range of ancillary equipment available

ICS Heat Pump Technology provide a range of accessories in order to simplify and enhance the heat pump package. Thisancillary equipment is usually difficult for the installer/contractor to source on a local basis and hence there is a reasonto source as a package with the heat pump to minimise installation time.

APPLICATION & SPECIFICATION SUPPORT

A heat pump installation can be simplified with theaddition of essential components which are provided toreduce the potential difficulty in sourcing specific itemslocally. ICS essential components are items that an on-site installation team may find difficulty in sourcing ona timely local basis. Importantly these essentialcomponents do not include any fittings or pipe workrelating to the installation but are designed to providethe more specific heat pump related items:

ADDITIONAL ANCILLARY EQUIPMENT

41Accessories - General

Page 94: HQ Brochure

CPD & Training42

ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided within the product guide and/or data sheetsis intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.

INDUSTRY LEADING CPDCOMMERCIAL HEAT PUMP APPLICATION & SPECIFICATIONThe commercial heat pump application and specification CPD covers a variety of topics which wil provide the delegate with knowledge concerning existing technology and new heat pump development.

ICS provide a complete range of air source ground source/geothermal heat pumps with output temperaturesfrom 35ºC to 90ºC including their new commercial CO2 sanitary hot water/thermal storage production units.

The CPD covers heat pump applications ranging from 20kW to 2400kW applied to avariety of applications:

• Space heating - new build and retrofit oil/LPG boiler replacement

• Sanitary/domestic hot water production - conventional prioritised basis and bulk

low tariff thermal storage

• Heat recovery - recycle waste heat from production or process areas via air or water

The CPD is designed to widen the scope of the specifiers application knowledge and provides valuableupdates on the latest commercial heat pump technology.

The Continuing Professional Development (CPD) Certification process allows ICS Heat Pump Technology to provide information and

training on heat pump technology to Specifiers, Consultants and Engineers. The ICS Heat Pump Technology CPD Accredited program

helps keep construction & engineering professionals up-to-date with training support, new ideas and updates.

NEW

CO290ºC

WEB ACCESS CPD VIDEO

PRACTICAL & USEFUL TRAINING

The Air Source Specification and Application training module is intended to provide the airsource heat pump specifier, system designer and installer with useful guidance and advicerelating to the design, specification and installation of air source heat pump based heatingand sanitary hot water systems.

This new initiative for 2011/2012 takes heat pump training to the next level where the negative as well as the positive elementsof heat pump application are considered, this provides attendees with the skills and knowledge to take their heat pump businessforward in a profitable and efficient direction by working to best practice standards from design to completion.

PLEASE NOTE: This course is most suitable for experienced heat pump specifiers, system designers and installers, as thecontent is designed to improve existing knowledge rather than provide more basic entry level information.

SPECIFICATION APPLICATION TRAINING

Page 95: HQ Brochure

43

Glasgow*

Dublin

Bradford

Blackpool

Birmingham

Southampton

*Regional Distributor, Thermsaver

COMPLETE TECHNICAL AND SERVICE SUPPORT WITH A SPECIALIST TEAMPROVIDING PRE INSTALLATION, COMMISSIONING AND AFTER SALES SUPPORT TOMATCH THE REQUIREMENTS OF EACH PARTICULAR PROJECT

Technical & Service Support

• 5 UK service centres nationwide

• Specialist heat pump service team

• Commissioning service

• Technical/Installation support

• Technical help desk service

• Direct manufacturer support

3 24/7 Access to invaluable product and technical information

3 Heat Pump selection and sizing tools

3 Direct contact to our in house dedicated technical and sales help desk

3 25+ field based service team

3 Direct access to the on-line Partner Marketing tools and support team

3 Latest Heat Pump News; company, product and industry; LCBP, RHI

3 Latest product and technical document updates

3 Partner Hub password protected user access

Page 96: HQ Brochure

2011 Product Guide v5

www.icsheatpumps.co.uk

3 Trident Business Park, Amy Johnson Way, Blackpool, FY4 2RP

T: 01253 685100 F: 01253 685101 e: [email protected]

Page 97: HQ Brochure

e l e c t r i c u n d e r f l o o r h e a t i n g s o l u t i o n s

www.devi.co.uk

Page 98: HQ Brochure

innovation

2 DEVI underfloor heating

experience

global leader

over 40 years DEVI is Europe’s leading electric underfloor heating

manufacturer and the preferred partner of many of the

UK’s leading housebuilders and developers, with sales

companies in thirty countries worldwide.

Established for over forty years, DEVI has designed and

installed underfloor heating in the UK, in projects

ranging from large apartment developments, to single

house applications. Working closely with developers

and architects, as well as builders and electricians, DEVI

has demonstrated commitment to providing unrivalled

project support from design through to installation and

after-sales care.

In January 2003, DEVI became a member of the Danfoss

Group, the world’s leading manufacturer of heating,

cooling and air conditioning products. With over 18,000

employees, the Danfoss group has 59 factories in 21

countries.

DEVI products are manufactured in two ISO9001

compliant factories in Veije, Denmark which also houses

our IT, Marketing and R&D departments.

quality

Page 99: HQ Brochure

Invisible comfort A comfortable, efficient and economical alternative to conventionalheating. DEVI systems are also invisible, providing total freedomwhen decorating and furnishing.

Heat rises Underfloor heating radiates heat evenly across the whole floor area,providing maximum comfort levels; warm feet and cooler at headheight, whereas traditional systems provide heat by convection; thehot air rises and leaves a mass of warm air at ceiling level, where itcools and returns as a draught.

Economical Typically, electric underfloor heating makes it possible to lower theaverage room temperature by 2ºC without affecting the level ofcomfort. This means that heating can be reduced by around 20%,which is both an economic and an environmental advantage.

Capital cost savings Once installed, there are no future maintenance costs or contracts toconsider. There is also no need to channel emissions out of thebuilding, which greatly simplifies the design process.

Health benefitsWith electric underfloor heating, there are no travelling dustparticles and no moisture content to support dust mites, whichgreatly benefits those who suffer from dust allergies and asthma.

Total floor solutions DEVI strives to ensure that the installation process is as efficient aspossible. Working closely with other organisations, we are able tooffer a total solution for your project, encompassing the work ofthree trades; insulation, heating installation and screed. As well asproviding one point of responsibility, this also means that the buildprogramme can be streamlined in order to achieve the highest levelsof efficiency. As an example; for a large project, in a typical weekDEVI would prepare the floor on a Monday and Tuesday, install theheating cables on Wednesday and Thursday and screed on a Friday.

Electric underfloor heatingYou

r ben

efits

DEVI underfloor heating 3

Your benefits

Page 100: HQ Brochure

1 DEVI underfloor heating

Product rangeCable systems

devimat• Provides warm, comfortable floors

• A self-adhesive mesh with ultra-thin heating cable pre-attached.

• Twin conductor heating cable; no second tail to return to the thermostat, saving installation time and cost.

• Can be installed within the thickness of the tile adhesive, whichis ideal where floor height is a consideration.

• Can be installed on top of the exisiting floor, or onto wood (100W/m2) or concrete (150Wm2).

Typical applications - kitchens and bathrooms.

deviflex heating cables • DSIG - single conductor cable, two cold tails with screen.

• DTIP - twin conductor cable, one cold tail with screen.

• Cables can be cast within a screeded floor or installed betweentimber joists.

• Cable type will be specified according to floor construction.

• Applications - total underfloor heating solutions for newbuilds, ice and snow melting, frost protection.

devicell dry insulation plates • Provides the perfect solution for quick and easy installation of deviflex cables under wooden floors - no screed or additionalpreparation required.

• Consists of a 12mm polystyrene plate covered with a 1mm aluminium plate.

• The combination of an insulating sub-floor and a heat-conducting surface ensures optimum heat reflection upwards.

• A relatively low amount of power is required to provide the desired temperature.

• Applications - total underfloor heating solutions beneath wooden floors.

Page 101: HQ Brochure

Thermostats - individual room control

Produ

ctran

ge

DEVI underfloor

devireg 535• Combined 7-day thermostat and timer; can be set to monitorfloor temperature, room temperature or a combination of thetwo.

• Can be locked to both minimum and maximum temperatures;well-suited to wooden floor applications.

• Lowest standby consumption on the market, max 0.30W.

• Additional feature - child lock safety function.

devireg 550• Combined 7-day thermostat and timer, can be set to monitorfloor temperature, room temperature or a combination of thetwo.

• Intelligent pre-heat function enables the controller to calculateexactly what time the system should be switched on to achievethe required temperature, set by the user.

• Continually learns from its environment and automatically adjusts heating to meet comfort levels regardless of changingweather conditions.

• This accurate control ensures an exceptionally high level of energy efficiency and minimal running costs.

devireg 130• Basic surface mounted thermostat, well-suited to floor warming applications.

• Uses a floor sensor to monitor the floor temperature, butwith no timer.

• The single dial on the 130 is used to control the temperature ofthe floor and also switch the system off.

For technical specifications, please see page 8.

Page 102: HQ Brochure

6 DEVI underfloor heating

deviflex installed onto concrete floors deviflex can be installed into floors utilising both on or off-peak tariffs. The system can be used as a direct acting systemusing on-peak electricity tariffs, available 24 hours a day andutilising electricity directly when you need it. Alternatively,DEVI’s off-peak heating system is designed to utiliseelectricity during low tariff periods.

Here, the cables are attached to either a foil-faced insulation,sound resiliant layer or polythene. A screed is then applied. Ifrequired, DEVI can work to Robust Standard Detail floorconstructions.

deviflex installed within wooden floors DEVI systems can be installed in all types of wooden floorconstructions and beneath wooden floorcoverings.

The precise control ensures that the temperature in the floorconstruction always corresponds to the tolerance level thatthe manufacturer of the floor surface has recommended.

This floor construction shows cables installed in betweentimber joists. The insulation is laid between the joists andthen the heating cables are fixed to the insulation. The joistsare notched or left short of the wall to allow the cables topass from one joist to another.

devicell DRY insulation platesdevicell DRY insulation plates are ideal for quick and simpleinstallation of underfloor heating beneath wooden floors.devicell can be laid onto both concrete and timber floor. Inthis case, the devicell plates are covered by an acousticunderlay and then the chosen floor covering.

Base-floor

deviflex cable

Screed

Adhesive (if applicable)

Fixing strip

Floor sensor

Insulation

Floor finish - can be tiles, wood,carpet, laminate (see below)

Floor surfaces

DEVI underfloor heating systems are suitable for use withmost types of floorcovering, including wood, laminate,ceramic tiles, natural stone and vinyl. The cable systems arealso suitable for areas that are carpeted.

Wooden joists

Plywood

Floor constructions Loose-laid cable systems

deviflex cable Floor sensor

Timber floor

Fixing strip

deviflex cable Floor sensor

Underlay

Wooden floor covering

devicell DRY insulation plates

Notches in joists, metal linedand capped

Insulation

Page 103: HQ Brochure

devimat installed onto concrete floors The devimat system is a floor warming system used inconjunction with a primary heat source. In some applications,the output of the system is able to provide comforttemperatures depending on the heat loss of the building.

In this floor construction (opposite) the mat is installed ontoeither a new screeded floor or an existing sub-floor, then thetile adhesive and floorcovering applied.

Heating output - devimat 150 W/m2 suitable for installationonto concrete floors.

devimat installed onto timber floorsdevimat can also be installed directly onto a suitably rigidtimber floor construction. The adhesives and floor coveringsare then laid as normal.

Heating output - devimat 100 W/m2 suitable for installationonto timber floors.

devimat onto tile backer boardIf the devimat is installed onto a tile-backer insulation board,onto timber floors, a higher output can be installed.

Heating output - devimat 100/150 W/m2, suitable forinstallation onto a tile backer board.

• The supplier of the floor surface should always be consultedwith regard to the adhesives that are used.

• The floor manufacturers instructions on maximumtemperatures should always be followed.

• If the floor surface consists of wood or plastic, the cables mustbe covered with a suitable screed thickness, according to BritishStandards BS8204.

Floor covering can be tiles, woodlaminate or vinyl

Floor covering can be tiles, wood,laminate, vinyl

Floor covering can be tiles,wood, laminate or vinyl

Adhesive/self levellingcompound

Adhesive/self levellingcompound

Adhesive

Wooden joists

Wooden joists

Plywood

Tile backer insulation board

Floor sensor

Floor sensor

devimat

devimat

devimat

Floor sensor

Existing new orscreeded floor

Floorcon

struction

san

d fin

ishe

s

DEVI underfloor heating 7

Base-floor

Insulation

Matting systems

Page 104: HQ Brochure

8 DEVI underfloor heating

Total floor solutions DesignDEVI is commited to providing unrivalled project support,designing specific underfloor heating systems to match yourapplication and floor construction. DEVI manages the projectfrom design through to supply and installation and alsoprovides complete after-sales care and technical guidance.Designers at DEVI work with Auto-CAD to provide therelevant working drawings.

DEVI strives to ensure that the installation process is asefficient as possible, working closely with other organisationsto offer a total floor solution for projects; insulation, heatinginstallation and screed.

As well as providing one point of responsibility, this meansthat the build programme can be streamlined in order toachieve a high level of efficiency.

InsulateThe need for acoustic and thermal insulation is now arequirement of Part E and Part L building regulations. DEVIoffers an effective solution, in order to minimise heat loss andprovides measurable sound proofing to meet theserequirements. DEVI supply and install thermal and acousticinsulation to comply with specifications.

Install DEVI offers a full installation service and aim to work withinthe constraints of the agreed build programme in order tohand over a completed floor solution. Please see floorconstructions on page 6 for details on how DEVI heatingsystems are installed.

ScreedAfter installation of both the thermal/acoustic insulation andthe underfloor heating, the floor screed is then laid,(depending on the floor construction). DEVI can specify thesuitable screed for your application working in conjunctionwith a number of other companies. The completed floor isthen ready for the laying of chosen floor finishes.

Page 105: HQ Brochure

Techn

icalspecification

sProduct Features

deviflex DSIG deviflex DTIP deviflex DSIA deviflex DSVK devimat devicell DRY

Cable construction Single conductor Twin conductor Single conductor Single conductor Twin conductor DTIP-10 cables used

Rated voltage 230/400V 230/400V 230/400V 400V 230V

Watts per meter 20W/m 8, 10, 18 W/m 25 W/m 25 W/m 100 and 150 W/m2

Diameter 5.5mm 7.0mm 6.0mm 8.10mm 3.0-3.5mm

Conductor insulation PEX PEX PEX PEX FEP, teflon

Sheath PVC 90º PVC 90º PVC 90º XPVC 90º PVDF 120º

Rated temperature 65ºC 65ºC 65ºC 65ºC 120ºC

Approval IEC 800/CE IEC 800/CE IEC 800/CE IEC 800 IEC 335-2-96/SEMKO

Warranty 10 years 10 years 10 years 2 years 10 years

Plate size 50 x 100 cm

Insulation value (U) 3

Thickness

13mm including 12mm flame retardent EPS

and 1mm aluminium

Deformation strength 3.67 tonnes/m2

Accessories in box locking bushells

DEVI underfloor heating 9

Product Features

devireg 130 devireg 550 devireg 535 devireg 330 devireg 850

Rated voltage 180 -250V~50Hz 180-250V~50/60Hz 180-250 V~50/60 Hz 180-250 V~50/60 Hz 180-250 V~50/60 Hz

Warranty 2 years 2 years 2 years 2 years 2 years

Temperature rangeroom sensor 5ºC to 45ºC or off 5ºC to 35ºC or off 5ºC to 35ºC or off

TEMP. SETTING--10ºC to +10ºC or off

TEMP. SETTING--9.9ºC to +-0.1ºC

Temperature rangefloor sensor only 20º to 50ºC 20º to 50º C 5º to 45º or off

MELTING TEMP. SETTING-+1ºC to +9.9ºC

Resistive Load 16A/3600W 16 A / 3600W 230V~15A/3450W 250V~16A/10A 250V~3 x16A

Inductive Load cos= 0,3 max. 4A cos= 0,3 max.1A cos= 0,3 max. 4A 3A 1A

IP Class IP30 IP30 IP31 IP20THERMOSTAT - IP30

SENSOR - IP67

Sensing Unit NTC;15Ohm/25ºC NTC;15Ohm/25ºC NTC;15kOhm/25ºC NTC;15kOhm/25ºC

ProductApplication

deviflex DSIG

deviflex DTIP

deviflex DSIA

deviflexDSVK

devimat devicell devireg 535/550

devireg 130 devireg 850 devireg 330

New build - screeded floor √ √ √ √ √ √

New build -timber floor

√ √ √ √ √ √

Renovation √ √ √ √ √ √

Frost Protection √ √ √ √

Ice and snowmelting

√ √ √ √ √

Page 106: HQ Brochure

10 DEVI underfloor heating

“We wanted a modern, high-tech heating system that fitted theclean and simple design principles of the product and gavehomeowners ultimate flexibility to maximise their living spaceand furnish it as they wish. You can have space where and whenyou need it. Nothing could be simpler or more practical.”

Marc Carter, London Green Developments.

“The St James Group chose DEVI because of the company’s well-established reputation in the market place, the quality andefficiency of DEVI’s products and the company’s friendly andefficient approach.”

Baber Malik, Project Manager, St James Homes.

“DEVI was chosen for Celtic Shores following our use of theproduct in previous developments where it has to be aneconomical, clean and controllable form of heating. Once again,the service provided was excellent and we are already using thesystem on another project.”

Barry Evans, TP Estates.

“We had a lot of technical questions which were all answeredcomprehensively and quickly. The installation was carried outprofessionally and efficiently and as a result we are now lookingforward to working with DEVI on a second project.”

Dave Skeet, Build Director, Thomas Homes.

Omega 3, Bow, London Green Developments

Kew Riverside, London, St James Group.

Celtic Shores, Whitsand Bay, Cornwall.

Testimonials

Donnington Elms, Newbury, Thomas Homes.

Page 107: HQ Brochure

Name:

Address:

Tel: Fax:

e-mail address:

Project name:

Project status:Research stage Planning applied for Planning approved Building started

Project type:

New build construction: Brick/block Timber frame other - Please specify

Floor construction: concrete floating suspended timber

Sectional floor build-up:

Further information; please make a note here of any other information you feel is relevant.

Company:

Request a quote

Please return this form via post/fax/email, (contact details on reverse).

Alternatively, call our Project Sales Team direct on 0845 434 9488. If you require a full,comprehensive quotation, please send full dimensions and plans along with this form.

DEVI underfloor heating 11

Requ

est a qu

ote

Page 108: HQ Brochure

D E V I E l e c t r o h e a t L t d , B r i c k f i e l d s B u s i n e s s P a r k , W o o l p i t , S u f f o l k I P 3 0 9 Q S

T : 0 8 4 5 4 3 4 9 9 9 1 F : 0 8 4 5 4 3 4 9 4 8 9 E : p r o j e c t s @ d e v i . c o . u k w w w . d e v i . c o . u k

Fron

t cov

er im

ages

; DEV

I ins

talle

d ap

artm

ents

, cou

rtes

y of

App

lecr

oss

and

Redr

ow H

omes

.

Page 109: HQ Brochure

Underfloor heating is a modern, cost effective option for heating commercial or domestic properties; it is simple and quick to install and energy efficient. The nature in which heat is radiated across the whole floor surface makes it a highly cost efficient and comfortable alternative.

Devi Hydronic is a wet underfloor heating system that utilises water at low temperatures. The water is circulated through a series of continuous pipe loops laid within a screed or between timber joists beneath the floor surface. The pipe loops for each room (or zone) all run from, and back to the system manifold.

Devi Hydronic underfloor heatingA cost effective and comfortable underfloor heating system

Your benefits • Economical and efficient- No wasted heat at ceiling level, accurate control• Comfort - High comfort levels at reduced overall temperatures• Capital cost savings – Reduced on-site maintenance, servicing of boilers/ pumps required only• Creates space – Provides complete design freedom• Hygienic - No travelling dust particles or moisture content to support dust mites• Longevity – Projected life span in excess of 50 years• Multi-layer oxygen proof pipe - Protection from corrosion and lime scale• Low noise transition - Low frictional resistance through pipe and fittings• High quality - All DEVI products are manufactured to ISO 9001 standard• Sophisticated controls – wired or wireless options

Why DEVI?Total floor solutions - DEVI can provide a total solution for your project encompassing, insulation, heating and screed. DEVI will manage your project from design through to supply and installation giving you just one point of responsibility which greatly simplifies the design process.

A service that adds value- DEVI has a fully qualified in-house design and technical team who will work with your designated Account Manager to provide you with project specific solutions. DEVI products are manufactured to ISO9001 standard and are backed up by a ten year manufacturer’s warranty.

Experience - Established for over 65 years, DEVI is the preferred partner of many of the UK’s leading house builders and developers. In January 2003, DEVI became a member of the Danfoss Group, the world’s leading manufacturer of heating, cooling and air conditioning products.

Simple installation

www.devi.co.uk

Page 110: HQ Brochure

3. Actuators

Available in 24V/230V

4. Thermostat/Control options

As with any heating system, the method of control is key. Devi can offer intuitive wired controls or the devilink wireless system ensuring maximum control and optimum efficiency.

devilink™ - wireless control • devilink™ enables control of the entire system via one central point.• The system consists of a simple colour touch screen panel which is used to control room sensors and floor thermostats throughout the building. • All thermostats are linked together wirelessly. • Periods of low temperature can be set, (i.e. at night or when going on holiday), thus saving energy.

Devi Hydronic - System elements 1. Devi-Hydronic Pipe and clamping track

Ultra-flexible and lightweight – can be

simply unrolled and clipped into the clamping tracks by hand, without awkward springing back

Blue plastic-metal compound pipe, oxygen-proof – Protected from corrosion and lime scale. The pipe is completely covered with screed, resulting in high heat conduction and the energy efficiency.

Insulation, durable and effective - DEVI compound insulation is installed along with the edge insulation strip. This forms a protective trough for support the screed.

Clamping tracks – quick installation - Self-adhesive clamping tracks fix the compound pipes at defined spacing. Clamping tracks are applied on the compound insulation at intervals of 1 to 1.5m.

2. Devi-Hydronic Manifold

Devi provides a manifold, consisting of a manifold, manufactured using high quality stainless steel. The system can also include a manifold cabinet (either flush mounted or surface mounted). Manifolds are available – 2 - 12 underfloor heating circuits.

The control units are complete with a 24V transformer for a wired system or 230V for wireless.

5. Wired thermostats

Features• Simple to use, equipped with maximum and minimum limitation of range• Thermal feedback function, improving accuracy• LED to indicate heat demand• Supplied for 24V or 230V power supply• Tamper proof – ideal for public environments• Manual night set-back feature available

Danfoss air/water and geothermal heat pumps - An on-site renewable energy source

Extremely high levels of efficiency are achieved when using a heat pump in conjunction with our DEVI Hydronic underfloor heating system.

Danfoss Heat Pumps provide heat and hot water by using renewable stored energy from the air, water, bedrock and ground - an endless renewable and free energy source. Energy cost savings of up to 75% can be achieved when compared with conventional heating methods.

For further information, call our project sales team on 0845 434 9488, fax 0845 434 9489 email [email protected]

Page 111: HQ Brochure

Kingspan Powerpanel Integrated PV Solutions

Cost-effective renewable energy solutions for all

sectors from Kingspan Panels providing valuable

inflation-proof electricity, reducing carbon emissions

and improving energy efficiency.

Page 112: HQ Brochure

Insulate and Generate Building Solutions In line with Kingspan’s ‘envelope first’ approach to sustainable building, Kingspan Powerpanel PV systems can make a valuable contribution to reducing the carbon emissions of a building, providing clean, inflation-proof electricity without the need for fossil, wind or nuclear fuels. Kingspan’s experienced design engineers work with building owners, architects, engineers and other building professionals to ensure that the right solution is found to meet BREEAM requirements, to satisfy 10% renewable energy targets or to meet Corporate Social Responsibility (CSR) needs.

Kingspan offers a single-source integrated roof, wall and solar provider Integrated, value-engineered PV systems designed to work with Kingspan roof and wall products to provide complete building solutions, backed up by Kingspan’s customer service and technical support.

Fixing Systems designed for Kingspan roofs The mechanical attachment mechanisms for our PV systems are specially designed for Kingspan roof profiles and Kingspan have carried out extensive structural and mechanical testing on all of our roof panel specific PV mounting solutions. Kingspan avoid going back to the main steel work or purlins, eliminating the problems associated with this type of protrusion and reducing site installation time.

Kingspan 25 Year Total Guarantee The Kingspan PowerPanel Total Guarantee warrants the thermal and structural performance of the complete system, including the insulated panels, the modules, mounting and fixings of the solar panels and the power output.

Kingspan Powerpanel Solar Solutions for sustainable building

Page 113: HQ Brochure

Morrisons Distribution Centre Bridgewater

Massive rises in energy bills over recent years have made the refrigeration and storage of produce an increasingly costly part of modern farming. The owners of Lavenham Fen Farms installed a kWp which is not only providing them with free electricity to the farm but also generating additional income from the government feed in tariff.

Client: MorrisonsSystem Size: 503.5kWpBuilding Use: Distribution Centre Estimated Yield: 443,514kWh/yr

Lavenham Fen Farms Cambridgeshire

In 2011 Kingspan Powerpanel installed over 6 megawatts of solar PV systems in the UK across a wide range of building sectors including commercial and retail, healthcare, hotel and leisure, manufacturing and agricultural.

Client: Abbotts Ripton Farming System Size: 353kWpBuilding Use: Agricultural Estimated Yield: 307,585kWh/yr

Client: Ocean HousingSystem Size: 57kWpBuilding Use: Industrial Estimated Yield: 42,000kWh/yr

Total building refurbishment by Kingspan which involved replacing the asbestos roof with BREEAM A+ rated Kingspan KS1000RW roof panels and fitting a kWp polycrystalline PV system, making the investment one that achieves not only a significant building fabric improvement but also carbon reduction, energy self-sufficiency and energy/ income generation.

Innovative solar PV and insulation panel technology from Kingspan has been used at Morrisons South West Regional Distribution Centre to create one of the most energy efficient logistics facilities in Europe.

Kingspan Insulation Pembridge

Client: Kingspan InsulationSystem Size: 805kWpBuilding Use: Manufacturing Estimated Yield: 644,000kWh/yr

At 800kWp Pembridge is one of the largest rooftop PV installations in the UK and supplies a significant proportion of the site’s lighting and manufacturing electricity needs.

Stennack House St Austell Cornwall

Page 114: HQ Brochure

Kingspan Powerpanel is a fully integrated solar PV system. With Kingspan’s expertise in sustainable energy solutions customers can be assured that we not only have the expertise to design a solution that will suit your requirements but also the capacity to fulfil every aspect of your renewable energy project, from design and procurement to installation, commissioning and maintenance.

Kingspan have secured supply of a range of power-guaranteed solar technologies from industry leading solar manufacturers. Each supplier has been vetted in terms of health and safety, quality, technical and financial status to ensure they meet Kingspan’s bankability and financial fitness criteria and offer comprehensive guarantees. All our products are MCS accredited, which enables customers to fully utilise their PV installations and maximise returns from the Clean Energy Cashback scheme (Feed-in Tariffs).

\

New Car Showroom Manchester

Client: New Car ShowroomSystem Size: 49kWpBuilding Use: Motor Retail Estimated Yield: 39,935 kWh/yr

On this new build BREEAM project, a tilted PV system was patch welded to the roof membrane without the need for additional ballast, ensuring a fast installation. The complete installation and commissioning of the system took just one week.

Brook House

When renewable energy advisors, Sustainable Energy Systems Ltd (SES) came to refurbish one of their own buildings it made sense for them to install a PowerPanel system together with the Kingspan roof to improve the energy efficiency of their own building.

Client: SCS LtdBuilding Use: Offices

Further and more detailed case studies can be found on our website at www.kingspanpowerpanel.com

Page 115: HQ Brochure

In addition to Kingspan’s 25 year Total System Guarantee Kingspan offers a comprehensive post project install Operation and Maintenance (O&M) contract which will ensure that the PV system is running as efficiently as it should be at all times. We have designed our service to maintain the efficiency and performance of the PV system over time, and can offer varying levels of service to suit clients’ needs covering

Regular on-site technical checks

Remote monitoring

Service level agreements and guaranteed system performance for managed installations

Kingspan Powerpanel Maintenance and monitoring solutions

Page 116: HQ Brochure

Kingspan have a vision to be net zero across the Division and are aiming to reduce our reliance on fossil fuel based energy by 50% by 2015. At Holywell, our largest site, we have recently commissioned a 406kWp Powerpanel PV system designed to deliver 317,000kWh renewable electricity per annum. The site now has zero waste to landfill. In 2011 Kingspan were awarded 1st in Wales in The Sunday Times Best Green Companies 2011.

Feasibility study

Financial analysis

Project planning

Site installation

Commissioning

Maintenance

For all enquiries telephone 01352 717323

Customer Service and Technical Support

Whatever your photovoltaic requirements our technical advisors are able to offer technical support at every stage of your project

01352 717323

Page 117: HQ Brochure

07/11 Tel: 0116 2604050 www.ashwellbiomass.com

About Ashwell Ashwell Biomass is a specialist in providing biomass boiler solutions for businesses, housing trusts, councils, schools, hospitals, farmers and landowners.

Ashwell Biomass (formerly Engineering Services Limited) was established originally as a coal boiler manufacturer/installer and is now one of the UK’s leading biomass

boiler manufacturers and installers of biomass heating and hot water solutions, with over 200 installations in the UK. Our products Ashwell Biomass offers a complete range of biomass boilers, for the domestic, industrial and commercial market:

Ashwell GreenTec range – 15kW to 300kW

D’Alessandro range – 20kW to 2MW

Komforts range – 500kW to 8MW

Accessories Ashwell Biomass also produces conversion kits for existing commercial and industrial coal fired boilers, enabling both new and existing clients to benefit from the biomass fuels available. The result is an improved efficiency in excess of 20% as well as lower carbon emissions.

Our services Services offered by Ashwell include:

Installation / Design

Boiler House CAD Layouts

Containerised Plant Rooms

Bespoke Fuel Stores

Full Engineering Facility

Full B.M.S. Building Energy Management

Unrivalled After Sales Service & Technical Support

Service & Maintenance Contracts Our clients Our client/client sites include:

Nottinghamshire County Council

Rhondda Cynon Taff Council

Leicester Housing Association

National Trust

Duchess of Somerset Hospital

Makita Power Tools

Harpers Environmental (UK Waste)

About Biomass Plant based biomass fuel is considered ‘carbon neutral’ – it takes carbon out of the atmosphere whilst it is growing and returns it as it is burned. On a sustainable basis, biomass is harvested as part of a constantly replenished crop, maintaining a closed carbon cycle with no net change in atmospheric CO2 levels. The most common fuel sources used in biomass boilers are:

Wood chip

Wood pellets

Logs

Firewood Why Choose Biomass

Government subsidy available (see RHI scheme below)

Significant savings on fuel costs compared to other sources e.g. oil, coal, gas and LPG combined with security of supply

Reduced carbon footprint – lower CO2 emissions when compared with fossil fuels.

Environmental benefits - burning waste wood that otherwise might be sent to a landfill site;

Social benefits - local fuel source widely available resulting in local investment and employment.

Renewable Heat Incentive (RHI) scheme *NEW* The UK government has introduced the RHI scheme to encourage the switch to heat generated by renewable sources. This subsidy applies to qualifying biomass installations: Up to 7.9p paid per kWh of useful heat Tariff is dependent on the size of boiler Payable to owner of the equipment Payable on a quarterly basis, guaranteed for 20 years. Immediate eligibility See our website for full details

Page 118: HQ Brochure

[email protected] www.ashwellbiomass.com

Tel: 0116 2604050 Unit 12, 35 Pinfold Road, Thurmaston, Leicester, LE4 8AT

Boiler Ranges

The GreenTec wood pellet boiler range is manufactured in-house in Leicester. The boilers are Clean Air certified (models 150kW and above) and, being of modular design, offer an extremely versatile configuration of fuel feeds along with a much reduced footprint compared to the majority of biomass boilers. These pellet boilers are available over a range of outputs from 15 kW to 300 kW

Ashwell Biomass is the exclusive UK distributor of this comprehensive range of biomass boilers. The D’Alessandro boiler range is manufactured in Italy to ISO9001 quality standards and boilers are EN303/5 compliant where applicable. With boiler outputs ranging from 20kW to 2MW and versatility over a large range of fuel types, D’Alessandro boilers are suitable for most applications.

Ashwell Biomass is the exclusive UK distributor and installer of the Komforts boiler range. Komforts provides a range of bespoke boilers and complete boiler house solutions to provide hot water, steam and CHP. The advanced systems are individually manufactured to ISO9001 quality standards and are more suited to medium and large scale industrial/commercial solutions. Available output range from 500kW to 8MW.

Fuel Type Example Uses

Wood Chip X Small Commercial/ Industrial

e.g. Farm/ School √

Wood Pellets √ Domestic √

Logs X Medium Commercial/ Industrial

e.g. Office Block, district heating schemes √

Firewood X Large Commercial/ Industrial

e.g. Factory, Hospital X

Fuel Type Example Uses

Wood Chip √ Small Commercial/ Industrial e.g. Farm/ School √

Wood Pellets √ Domestic √

Logs √ Medium Commercial/ Industrial e.g. Office Block, district heating schemes √

Firewood √ Large Commercial/ Industrial e.g. Factory, Hospital √

Other √

Fuel Type Example Uses

Wood Chip √ Small Commercial/ Industrial e.g. Farm/ School

X

Wood Pellets √ Domestic X

Logs X Medium Commercial/ Industrial

e.g. Office Block, district heating schemes √

Firewood X Large Commercial/ Industrial

e.g. Factory, Hospital √ Other √

Containerised Bio Heat Cabins A cost effective boiler house and fuel store solution with shorter lead times and lower costs for planning. They are complete boiler houses incorporating boiler, pumps, pipework, fuel stores and electrical connections. Design and fabrication services

Boiler house design - for a boiler house layout offering optimum performance Hydraulic design/ installation – design to ensure appropriate sizing of boiler and integration into new/existing system, crucial for an efficient system. Fabrication - in-house facilities to design and manufacture bespoke steel fuel bunkers and feeds.

Indicative Boiler Sizes

Approximate boiler sizes for different projects or property

types are as follows:

Average 3 Bed House from 20kW Farms from 50kW Workshops from 60kW Primary School from 100kW Comprehensive School from 200kW

Hospital from 300kW

Accreditations

Page 119: HQ Brochure

www.aqua-lity.co.uk 1 | P a g e

Commercial Rainwater Harvesting Systems

Page 120: HQ Brochure

www.aqua-lity.co.uk 2 | P a g e

Rainwater Harvesting

Introduction Water, or the lack of water, is becoming an ever increasing issue in the UK and needs to be addressed as a matter of urgency. Climate change, over extraction of water resources and population growth are largely to blame for the current and future areas of water stress in the UK. Indeed, we are seeing an increasing use of Hosepipe Bans being implemented by a number of Water Companies in the UK as part of the measures to combat this very real problem New technologies like rainwater harvesting and greywater recycling enable us to reduce the water consump-tion by using resources that are mostly available to all of us – coming from the roof or draining from our showers, baths and hand wash basins. Why not make use of them?

Best water quality due to simple three step filtration/separation Rainwater is collected from the roof and collected via the gutter or siphonic drainage system. Before entering the storage tank, the water is filtered. Large particles such as leaves, moss and twigs are separated. The fil-tered water is fed into the storage tank via a calmed inlet, thus ensuring that the water inside of the tank stays calm and small particles can settle to the bottom or float to the surface. The water is then pumped to the ser-viced appliances via a floating extraction which always takes the water below the surface and above the bot-tom of the tank. The floating extraction has another filter to avoid fine suspended matter entering the supply.

Great benefits with little effort: Saving mains water Flood reduction due to storage tanks and usage Combinable with our greywater recycling systems Compact system and easy to install components Adoptable to every type of building due to flexible above or

below ground systems No use of chemicals Energy efficient system design Enhanced Capital Allowance applicable via Water Technology

List Complies with BREEAM, LEED, CFSH & WRAS requirements

Water quality If a rainwater harvesting system is professionally designed and installed, the water quality should be more than sufficient for non potable applica-tions such as WC flushing, laundry etc. More de-tails on the water quality are available in BS8515:2009.

Floating extraction

Floating layer

Sediment

Page 121: HQ Brochure

www.aqua-lity.co.uk 3 | P a g e

System Components High quality, compact & easy to install

1) Pre-Filtration Filtering out larger debris such as leaves

2) Rainwater storage tank collects and stores the incoming rainwa-ter 3) Supply pump (optional) supplies water from storage tank to con-trol unit unless tank is close enough to tank to prime directly 4) Aqua-Control Control unit with integrated booster pump set and mains water back-up ac-cording to BS8515 5) Expansion vessel Reducing run time of pumps and protect-ing equipment against small leaks

6) Soak away (optional) Infiltration system with pre-sedimentation pit

1

2 63

4

5

Example:Filtertank, AC 1100 control unit with supply pump arrangement

Different systems for different requirementsAquality offers a wide range of systems for all types of buildings such as: Educational buildings e.g. schools, universities, colleges, stu-

dent accommodations Retail buildings e.g. supermarkets, warehouses, distribution

centers’ Public buildings e.g. police, fire stations, prisons, council of-

fices Other commercial buildings

Different types of buildings may require different types of systems, such as: Above / below ground systems Gravity / direct systems Rainwater / Greywater Attenuation / Combined systems

Page 122: HQ Brochure

www.aqua-lity.co.uk 4 | P a g e

Pre-Filtration Highly efficient, manual to self-cleaning, low invert levels Aquality offers a vast range of filters to suit from 150m² to 60,000m² roof area. They can be installed underground, indoors or factory installed in our storage tanks. Filters should be self-cleaning but reality shows that maintenance cannot be avoided unless the filters are equipped with a self-cleaning mechanism. These can be semi-automatic or fully automatic. The majority of our filters are pre-fitted with semi/fully automatic cleaning facilities. Operation The commercial filters have been developed for large rainwater harvesting systems to cope with flow rates up to 1800 l/s. The filters use a special, purpose designed stainless steel grid with a filter mesh size of 0.7mm.

The filter grid elements are formed so that they make perfect use of the wa-ter molecule characteristics and therefore the water can pass to the storage tank at high collection efficiency of up to 99%. Dirt particles such as leaves, moss & twigs are separated out. This not only reduces the amount of organ-ic load reaching the tank, but also reduces potential maintenance of the storage tank itself. Particles will get stuck in the filter grid over time, so filter eventually needs to be cleaned. Debris can be removed by simply flushing the filter grid,

therefore access to the filter grids is essential. As most filters are underground installations, with potential confined space issues, a semi-automatic or even fully automatic cleaning system is recommended. The majori-ty of our filters are either semi or fully automatic. Fully automatic filters work in conjunction with Aquality’s control units.

Integrated Rainwater Filter

AWD filter – water diversion without mechanical moving parts: In cases where the rainwater needs to be diverted away from the tank when it is full e.g. due to low drainage connections, the AWD filter is the perfect option. It diverts the rainwater away from the tank by itself when the tank is full using a patented air bubble effect. Filter with high collection efficiency Stainless steel grid Water diversion without using moving mechanical parts Ideal for combination with greywater systems to comply

with BS8525

Separating dirt particles while keeping high filter efficiency

Semi-automatic filter arrangement

Page 123: HQ Brochure

www.aqua-lity.co.uk 5 | P a g e

Rainwater Storage tanks Highly flexible range for every situation 500 – 400,000 ltr capacity in a single tank

Aquality aims to provide a solution not a product. Therefore we offer a flexi-ble product range including tanks in all sizes that will suit any requirement – high loading, above or underground, modular & easy to transport.

The tank material is chosen to suit site specific requirements. All tanks are equipped with calmed inlets and an over-flow device as to BS8515. They can be factory fitted with a filter, thus easing in-stallation. Integrated filters will reduce drainage fall through the system.

For underground installations, GRP, PE Concrete & plastic box (crate) systems are recommended. For above ground installations, our large range of sectional/single piece GRP or PE-Tanks is the preferred choice.

Underground GRP Tanks are most commonly used for Rainwater Harvesting and can be supplied suitable for installation with either a pea gravel or concrete backfill. The site situation should be discussed at an early stage to assist in product selection, thus ensuring the most cost effective method of water storage is em-ployed.

Page 124: HQ Brochure

www.aqua-lity.co.uk 6 | P a g e

Aqua-Control units Compact booster pump set with integrated mains water back-up and controls The Aqua Control units have been developed to ensure a compact, easy to install product that can accommo-dates all necessary features of a modern rainwater / greywater control unit. They are purpose designed for the application to ensure integrated and external components will work as one. Operation The Aqua-Controls are fully equipped control units with integrated break tank, booster pump set and electronic control. The control unit monitors the water level in the rainwater tank as well as in the mains back up break tank. The self-priming booster pump set supplies the water directly to the applications. In case of rain- or greywater shortage or manual setting, the Aqua-Control feeds mains water automatically and on demand, via an AA-type air gap, into the intermedi-ate tank (in compliance with BS 8515 / BS 8525). As an automatic maintenance feature the solenoid valve of the mains water back-up system is regularly opened. If mains water has not been used for a certain time period the unit will flush the mains water pipe and thereby avoid stagnation. Preset standard set-tings can be adjusted to meet project specific needs. The units have a manual over-ride for maintenance and automatic switch over in case of supply pump failure from storage tank. The Aqua Control units have been developed to cover all design led requirements of a commercial sized building including operating safety, reliability, and energy saving. The systems offer in-depth monitoring ability for modern facility management.

These units are being used in all building types from schools, offices & supermarkets to airports and stadiums. The Aqua-Control 5000 is a unit that can be completely customised to all specific requirements. The units are very compact as the table below indicates.

Technical data AC 600 AC 1100 S AC 1500 Eco AC 2100 S AC 2500 Eco AC 5000 Height (mm) 1080 1200 1200 1200 1200 Customised Width (mm) 800 800 800 800 800 Customised Depth (mm) 400 400 400 400 400 Customised Weight (kg empty) 65 95 95 95 95 Customised Mains water connection 1” 1 ¼” 1 ¼” 1 ¼” 1 ¼” CustomisedPressure pipe connection 1 ¼” 1 ½” 1 ½” 1 ½” 1 ½” Customised Supply/Suction connection 1 ¼” 1 ½” 1 ½” 1 ½” 1 ½” Customised Emergency overflow (mm) 70 110 110 110 110 Customised Power supply 230V / 50Hz 230V / 50Hz 230V / 50Hz 400V / 50 Hz 400V / 50 Hz On demand Protection fuse (A) 20 20 20 16 16 On demand IP protection class 44 54 54 54 54 On demand All given data is subject to change.

AC 5000 supplying xxx WCs

Page 125: HQ Brochure

www.aqua-lity.co.uk 7 | P a g e

The following table shows the standard & optional features for each of the different unit models :

Features AC 600 AC 1100 S AC 1500 Eco AC 2100 S AC 2500 Eco AC 5000 Booster pumps 2 2 2 2 2 2-5 Max. flow rate (m3/h) 10 14 14 30 30 >30 Max. pressure head (bar) 5 7 7 6.65 6.65 customised Variable speed X X O PERCS® X X O Pre-wired in steel housing Steel console X X X X X Stabalisation feet X X X X X X Display panel 4-line LCD 4-line LCD Touch screen 4-line LCD Touch screen Touch screen Mains power switch X X X X X X Mains water back-up as to BS8515 / 8525

X X X X X X

Fully automatic and manual switch over to mains water

X X X X X X

Operation with below and above ground tanks

X X X X X X

Storage tank level indicator O X X X X X Break tank level indicator X X X X X Dry run protection X X X X X X Mains water fault alarm X X X X X X Pipe burst alarm function X X X X X X Leakage alarm function X X X X X Pump run-time indicator X X X X X X UV-Disinfection Synchroniser O X O X O Anti-MW-Stagnation control X X X X X X Dual storage tank control (Bas.) O O O O O Dual storage tank control (Adv.) O O O Second supply pump potential O O O O O O Educational panel connectable X X X X X X Data logger O O O Water consumption indication O O O O O Filter monitoring O O O Automatic filter cleaning O O O O O Automatic water drain down function

O O O O O O

Remote monitoring facility O O O Voltfree contact for BMS X X X X X X Advanced BMS via protocols O O O All given data is subject to change. X = standard features; O = optional

The choices allow rainwater harvesting and greywater recycling systems to be designed to building type and customer requirements with maximal environmental consideration and the highest degree of maintenance reduction and facility management control possibilities. On the next page some of the features are described in more detail.

Page 126: HQ Brochure

www.aqua-lity.co.uk 8 | P a g e

Pre-wired & fitted in a single, compact, steel housing Installation time & cost is reduced and the responsibility (warranty) to assemble the unit is taken away from the installer. The compact design will greatly reduce space requirement within the plant room. All connections are labeled for easy installation

Booster pumps All units will be supplied with at least two duty/assist stainless steel mul-ti stage pumps. Single pump failure will automatically operate the other pump to provide continuity of service and will operate alarm system to communicate the pump loss to the operator via BMS. PERCS The Pump Energy Reduction Control System not only reduces the energy for the pumping the non-potable water to its applications by using the used energy from supply to boost the water. Volt free contact for BMS connection The unit is pre-wired for connection to the client’s Building Management System and will provide a common fault signal which can then be inter-preted on the unit’s visual display

Advanced BMS via protocols The unit can communicate alarms via pre-wired connection to external building management systems. It will inform about alarm status and pinpoint specific faults. The following protocols can be used Ethernet, CanOpen and Profibus. Education/Corporate Panel connectable Pre-wired for quick and simple connection to the optional visual display panel. Unit will communicate tank wa-ter level, mains water and rainwater consumption and would be used for Educational or Corporate display to promote the building’s environmental credentials. Pipe burst alarm or leakage alarm function Unit will detect a major leakage / pipe burst in the pressure pipe serving the serviced appliances. In the event of pipe burst detection, the system will stop water supply to avoid potential flooding and consumption of water. This would then be signaled as an alarm status if connected to a BMS Mains water back-up fault alarm Unit will detect a fault in the mains water back up supply and communicate the problem by alarm

Unison HQ, London

Page 127: HQ Brochure

www.aqua-lity.co.uk 9 | P a g e

Remote monitoring facility Unit can be remotely monitored and will provide status / operational information, water consumption figures and the need for required maintenance thus minimizing the need to visit the system personally to check sta-tus. UV disinfection ECO-Synchronizer (patented) Unit will operate an optional UV Disinfection System in a way that will reduce run time and therefore signifi-cantly reduce energy consumption. The operation will reduce the need for consumable component replace-ment / maintenance and will greatly increase the life span of the Disinfection System Anti Stagnation control (programmable) Potential for stagnation of the incoming mains water supply due to infrequent use is eliminated by using the project programmable Anti Stagnation flush facility.

Automatic water drain down system Unit can drain down tank on demand or automatically due to set schedule. This will enable easy maintenance on tanks or ensure water quality as required in the BS 8525 for greywater recycling systems. Function will only work in conjunction with “drain down package” (available as accessory). Dual supply tank control (basic and advanced) Unit can operate two independent rainwater holding tanks and

will select water from tank holding the largest volume. The basic version will only transfer water to the second tank. The advanced version will allow the unit to decide from what tank to draw the water from first, depend-ant on water level. Data read out function Operational information can be downloaded to external device Water consumption indication Unit can display the amount of rainwater and mains water being used to allow for performance measurment of the system. This option is mandatory with the choice of an “education panel” and water meters (available as accessory).

TESCO Supermarket, Berwick

AC 5000 supplied 200 WCs at Westfield Shopping Centre, London

Page 128: HQ Brochure

www.aqua-lity.co.uk 10 | P a g e

References Rainwater Harvesting can be used in many buildings… here is just a small collection.

Westfield Shopping Centre, London Building type: Shopping Centre 2000m³ storage tank Rainwater is used for 200 WCs

Mariners Quay, Newport Building type: Residential

20,000l Filtertank Rainwater used for WCs

Student Accommodation, Listerhills Building type: Student Accommodation 2 x 40,000l storage tanks Rainwater used for WCs

SCRM, Edinburgh Building type: Office 20,000l storage tank

Rainwater used for WCs and wash down points

Sainsbury’s, Exeter Building type: Supermarket 30,000l GRP tank with filter Rainwater used for WCs

Padiham Primary School, Burnley Building type: School

16,000l Filtertank Rainwater used for WC and irrigation

Page 129: HQ Brochure

www.aqua-lity.co.uk 11 | P a g e

Aquality Trading & Consulting Ltd. Aquality Trading & Consulting Ltd is one of the longest established and leading suppliers of rainwater harvesting and greywater recycling systems in the UK and France. With decades of in-house experience in this market, we pride ourselves in offering a complete package to Design-ers, Consultants, Mechanical Contractors, Building Contractors, Civil Engineering Contractors and end users in both the Commercial and Domestic market. We offer:

- free initial design assistance, - detailed design, - system supply, - installation, - maintenance and - a full after sales service package.

We provide Rainwater Harvesting and Greywater Re-cycling Systems covering all project types, from a sin-gle domestic house to some of the largest ever pro-jects in the UK, such as the Westfield Shopping Centre in London. We provide individual tailored solutions for stormwater and non potable water management, including sustaina-ble urban drainage systems such as green roofs and attenuation systems. We offer Rainwater Harvesting and Greywater Recycling CPD presentations for industry professionals seeking to learn more about how this simple, yet effective, technology can enhance their building project. We are members of the UKRHA (UK Rainwater Harvesting Association), UKGBC (UK Green Building Council), FBR (German Rainwater Harvesting Association), ARCSA (American Rainwater Catchment Systems Association) as well as the CIPHE (Charted Institute of Plumbing and Heating Engineers). Our Managing Director, Lutz Johnen, is well respected in the industry and is the current chairman of the UK Rain-water Harvesting Association, is a member of the British Standards Committee (dealing with BS 8515 - Rainwater Harvesting and BS 8525 - Greywater Recycling).

Aquality Trading & Consulting Ltd. 35 Warple Way London W3 0RX

Tel: 0208 746 4200 www.aqua-lity.co.uk

Page 130: HQ Brochure

www.aqua-lity.co.uk 1 | P a g e

Aqua-Recycling-Control Greywater Recycling System

Page 131: HQ Brochure

www.aqua-lity.co.uk 2 | P a g e

Greywater Recycling

Introduction Water, or the lack of water, is becoming an ever increasing issue in the UK and needs to be addressed as a matter of urgency. Climate change, over extraction of water resources and population growth are largely to blame for the current and future areas of water stress in the UK. Indeed, we are seeing an increasing use of Hosepipe Bans being implemented by a number of Water Companies in the UK as part of the measures to combat this very real problem. We have a plentiful supply of water that could be used - from the roofs of our buildings or the waste from our baths and showers Why not make use of them? Best water quality due to most modern BioMembrane Technology The chemical free treatment process is using the latest technology and safest water treatment method for greywater recycling: Bio-Membrane-Technology (BMT). The membrane has a 38nm filter pore size. Every Membrane pore is 2.500 times finer than the human hair and therefore creates an impassable barrier for every particle and even bacteria. After treatment the water is available again as clean, clear, odorless and germfree non-potable water.

The treated greywater complies with: British Standard BS8525-1:2010 European Bathing Water Regulation

2006/7/EG

Great benefits with little effort: Saving mains water and sewage charges Mains water savings independent of the weather Quick financial returns compared to other renewable tech-

nologies Long storage periods of treated water Combinable with rainwater harvesting Little space requirements due to compact systems Adoptable to every type of building due to modular based

above or below ground systems No use of chemicals Enhanced Capital Allowance applicable via Water Technology

List. Complies to BREAAM, LEED, CFSH requirements

Page 132: HQ Brochure

www.aqua-lity.co.uk 3 | P a g e

Aquality’s Aqua-Recycling-Control Space saving, highly efficient, modular system 1) Coarse filter with back wash facility

2) Greywater buffer tank collects the incoming water for treatment 3) Aerator supplies water with oxygen and keeps membranes free from dirt deposits 4) Membrane filter guarantees the high water quality

5) Clear water storage keeps water available for use

6) Aqua Recycling-Control monitors and controls the treat-ment process

7) Aqua-Control booster pump set with mains water back-up facility and controls 8) Floor drain is needed as a safety measure

Operation The greywater is filtered/treated in three controlled stages in the Aqua-Recycling-Control (ARC) system. First the water passes a coarse filtration stage in order to separate larger dirt particles (hair etc). Then, the wa-ter enters the aerobic treatment buffer tank. Here, the incoming water is collected and aerated. Next, in the membrane tank the water is passes through the BMT-Membrane and is lift-ed to the clear water storage tank. From the clear water storage tank the water is pumped via the Aqua-Control booster pump set to the serviced appliances. If no treated greywater is available or the tanks are undergoing maintenance the Aqua-Control will change to mains water back-up using a WRAS compliant air gap.

1

2

7

6

3

4

5

8

Low running cost and simple maintenance: The biomechanical Aqua-Recycling-Control only uses electricity to operate its effective treatment process. No chemical additives, no refilling of expensive non environmental substances. The only element that needs cleaning is the membrane. When the filtration rate is reduced, the system will automatically indicate the need for maintenance - even remotely (maintenance on demand). The membrane is simply exchanged for cleaning by our service team - Quick and without hassle or down time on site.

Page 133: HQ Brochure

www.aqua-lity.co.uk 4 | P a g e

Installation examples Above ground system The Aquality greywater systems are very flexible in design, due to their modular construction. Moreover, they use lit-tle space to treat significant amounts of water. Here are just two examples of possible plant room configu-rations. The table below states typical plant layouts which will help to get a first idea on space requirements.

Item

number Unit Treatment

Capacity in ltrs per day

Typical space Requirement*

W x D x H in mm

Typical space Requirement** W x D x H in mm

G 17001 ARC 40 B+ 1,000 1,500 x 2,000 x 2,200 1,500 x 2,000 x 2,200 G 17200 ARC 80 B+ 2,000 3,000 x 2,100 x 2,200 3,000 x 2,500 x 2,200 G 17210 ARC 160 B+ 4,000 3,500 x 2,300 x 2,200 5,500 x 2,500 x 2,200 G 17220 ARC 240 B+ 6,000 4,300 x 3,300 x 2,200 6,500 x 3,100 x 2,200 G 17230 ARC 320 B+ 8,000 7,000 x 2,800 x 2,200 8,000 x 2,900 x 2,200 G 17234 ARC 400 B+ 10,000 9,000 x 2,700 x 2,200 11,300 x 2,900 x 2,200 G 17236 ARC 480 B+ 12,000 9,000 x 2,900 x 2,200 11,500 x 2,900 x 2,200 G 17240 ARC 560 B+ 14,000 10,500 x 3,200 x 2,200 13,500 x 3,200 x 2,200 G 17245 ARC 640 B+ 16,000 12,500 x 3,200 x 2,200 15,000 x 3,200 x 2,200

*Based on typical greywater intake in a residential building. Other building types may vary. **Based on typical greywater intake in an office building. Other buildings types may vary. Allow for a minimum of 500mm working space around equipment and minimum of 500mm headroom. For more detailed design please contact our design team. We reserve the right for technical changes.

6,000l/d treatment unit with AC 1100 control unit

14,000l/d treatment unit with AC 1100 control unit

Page 134: HQ Brochure

www.aqua-lity.co.uk 5 | P a g e

Below ground greywater recycling No basement or plant room available…no problem If there is no space within the building, the greywater recycling system can be installed underground. The different treatment processes stages, mirroring the above ground system, are carried out in either sepa-rate tanks or by using structural baffles in a single tank. Generally the control as well as the compressor units would be installed in a plant room. In case there is no plant room available these components can be housed in a weather proof housing/kiosk.

Tank design for large outdoor greywater recycling system with rainwater add-on

Combined systems Why not use both sources – greywater and rainwater? Greywater can be limited especially when looking at offices or other building types that do not include showers. All buildings will have some kind of roof which might not have been sufficient for rainwater harvesting but in combination with greywater becomes a viable op-tion. Combining these systems also has the advantage that whenever the clear water storage tank is full, due to sufficient rain, the greywater recycling system stops treating any further greywater. This will not only reduce energy demand but also minimises maintenance for the greywater recycling system. The add-on costs are minimal. Only a rainwater filter and an enlarged clear water storage tank are needed to go from a greywater only sys-tem to a combined greywater & rainwater system.

greywater and rainwater?

Indoor combined rainwater harvesting and greywater recycling system in an office building

Waterproof cabinet for outdoor system

Page 135: HQ Brochure

www.aqua-lity.co.uk 6 | P a g e

Aqua-Control 1100S / 1500 Eco Compact booster pump set with integrated mains water back-up and controls

Features: Integrated self-priming double booster pump set with multiple-

staged, horizontal centrifugal pumps, max. flow rate up to 14m3

Demand activated booster pump control (cascade principle) /h

Automatic, demand activated and water efficient mains water back-up via integrated break tank and AA-type air gap (BS 8515 / BS 8525)

Dual storage tank control Integrated touch screen (AC 1500 Eco) or 4-line LCD display (AC 1100

S) for indication of operation status, system pressure, level in rainwa-ter holding tank, run time meter per pump, settings and detailed failure indication etc.

Automatic and manual changeover to mains water supply Integrated dry run protection, mains water back-up fault alarm,

switchable pipe burst and leakage alarm function Fully adjustable stagnation prevention for mains water pipe Volt free contact (3A @ 30VDC) for alarm signal or general fault message to building management

systems. Pressure and water level sensor included, control and all internal components pre-wired and pre-

installed in a compact powder coated steel housing with isolation switch Pre-wired for connection to monitoring unit “Educational/Corporate Panel”

Aqua-Control 1500 Eco only: Leading pump with variable speed control Integrated UV-synchronizer control for low energy use of UV treatment system

Operation The Aqua-Control is a fully equipped control unit with integrated break tank, double booster pump set and electronic control. The control unit monitors the water level in the greywater tank as well as in the mains back up break tank. The self-priming double booster pump set supplies the water directly to the applications. In case of greywater shortage or manual setting, the Aqua-Control feeds mains water automatically and accord-ing to demand into the intermediate tank (in compliance with BS 8515 / BS 8525 / WRAS). As an automatic maintenance feature the solenoid valve of the mains water back-up system is regularly opened. If mains water has not been used for a certain time period the unit will flush the mains water pipe and thereby avoid stagna-tion. Preset standard settings can be adjusted to meet project specific needs.

Page 136: HQ Brochure

www.aqua-lity.co.uk 7 | P a g e

Optional features: Control package for second storage tank – basic (G13342) Monitoring unit “Educational/Corporate Panel” (G15031) 1 ½“ Water meters for “Educational/Corporate Panel” (G15032) Water meter reading indicator in connection with G15032 Automatic tank drain down and replenish system (G13341) Filter cleaning - TF filters only (G13349)

These features are only available for 1500 Eco: BMS connection – Profibus, Ethernet, or CanOpen (G13345) Control package for second storage tank – advanced (G13343) Filter monitoring - AWD filters only (G13348)

Technical data:

Power supply (1~230 V / 50 Hz) A B C D E

Max. flow rate [m³/h @ minimum head] 8 8 8 14 14 Max. head [m @ minimum flow rate ] 42.2 57.7 72 47.3 59 Motor output [kW] 2 x 0.880 2 x 1.200 2 x 1.480 2 x 1.200 2 x 1.480 Max input current [A] 7.8 10.6 12.6 10.6 12.6 IP rating control 54 54 54 54 54

Item No Aqua-Control 1100 S G 13320 G 13321 G 13322 G 13323 G 13324

Item No Aqua-Control 1500 Eco G 13325 G 13326 G 13327 G 13328 G 13329

There are units with higher flow rates and pressure supply available on request.

Width [mm] 800

Depth [mm[ 400

Height [mm] 1,200

Weight empty [kg] 95

Weight max. [kg] 135

Integrated break tank [L] 40

Emergency overflow [mm] 110 OD

Pressure pipe connection 1 ½ "

Suction pipe connection 1 ½ "

Mains water connection 1 ¼ "

Page 137: HQ Brochure

www.aqua-lity.co.uk 8 | P a g e

Project References Greywater recycling can be used in many buildings… here are a few examples.

Severn Trent HQ, Coventry Building type: Office Combined rainwater harvesting (12m3 tank) with greywater recycling (500l/d) and bore hole water system

Scunthorpe Leisure Centre Building type: Leisure Centre

10,000l/d system. Treated greywater is used for WC

flushing and pond top-up Mann Island, Liverpool Building type: Office Very compact 12,000l/d system built on two floors.

Watford Fire Station Building type: Fire Station

500l/d underground system

Commonwealth Pool, Edinburgh Building type: Leisure Centre 12,000l/d system installed under pool in two process strings

Mariners Quay, Newport Building type: Apartment Blocks

System size: 3x 3,000l/d

Page 138: HQ Brochure

www.aqua-lity.co.uk 9 | P a g e

Aquality Trading & Consulting Ltd. Aquality Trading & Consulting Ltd is one of the longest established and leading suppliers of rainwater harvesting and greywater recycling systems in the UK and France. With decades of in-house experience in this market, we pride ourselves in offering a complete package to Design-ers, Consultants, Mechanical Contractors, Building Contractors, Civil Engineering Contractors and end users in both the Commercial and Domestic market. We offer:

- free initial design assistance, - detailed design, - system supply, - installation, - maintenance and - a full after sales service package.

We provide Rainwater Harvesting and Greywater Re-cycling Systems covering all project types, from a sin-gle domestic house to some of the largest ever pro-jects in the UK, such as the Westfield Shopping Centre in London. We provide individual tailored solutions for stormwater and non potable water management, including sustaina-ble urban drainage systems such as green roofs and attenuation systems. We offer Rainwater Harvesting and Greywater Recycling CPD presentations for industry professionals seeking to learn more about how this simple, yet effective, technology can enhance their building project. We are members of the UKRHA (UK Rainwater Harvesting Association), UKGBC (UK Green Building Council), FBR (German Rainwater Harvesting Association), ARCSA (American Rainwater Catchment Systems Association) as well as the CIPHE (Charted Institute of Plumbing and Heating Engineers). Our Managing Director, Lutz Johnen, is well respected in the industry and is the current chairman of the UK Rain-water Harvesting Association. Lutz is also a member of the British Standards Committee (dealing with BS 8515 - Rainwater Harvesting and BS 8525 - Greywater Recycling).

Aquality Trading & Consulting Ltd. 35 Warple Way London W3 0RX

Tel: 0208 746 4200 www.aqua-lity.co.uk