HELUWIND ® WK POWERLINE ALU 105°C, 0,6/1kV flexible ALU-Conductor Properties Cable structure Technical data Aluminium conductor, fine stranded wires Temperature range fixed -40°C to +105°C flexing -20°C up to +90°C UV resistant oil-resistant Special insulation black Sheath special compound easy to assemble Operating temperature at conductor max. +105°C recyclable black jacket Nominal voltage 0,6/1kV (50Hz) Note Please ask for our extended notes/information about the properties and for the necessary connection technology. Please contact us with your individual requirements via fax +49 7150 9209 5135. Test voltage 2,5kV (50Hz) Min. bending radius flexing 10 x cable outer diameter fixed installation 4 x cable outer diameter Flame test IEC 60332-1 Approvals acc. to DIN VDE 0250-813 UL/CSA in preparation Application The WK Powerline ALU is a highly flexible aluminum cable with a fine wire strand structure, which is suitable for use in the area of energy management - especially in the power wiring of a wind turbine. Thanks to its high flexibility and low weight, this cable can be installed in the tower in one continuous length. Time-intensive wiring of the individual tower segments is eliminated. The decisive advantage, however, lies in the process safety of the connection technology: The number of breaks from the top tower segment to the inverter is reduced from as many as 90 connection points to only 18 connections, depending on the number of power cables and tower segments. The installation effort in the field is thereby reduced from several days to a few hours. For torsional use we recommend the WK 103-T, WK 135-T or WK 137-T. The WK Powerline ALU may only be prepared with the certified connection technology of HELUKABLE ® . Either with the C8 Crimp or screw connector (tested in accordance with IEC 61238-1 Cl. A). See Accessories section in the catalog. The cable is also optionally available in a halogen-free design with UL/CSA approval and a rated voltage of 1.8/3 kV. = The product conforms to the EC Low Voltage Directive 2006/95/EC Weight approx. kg / km AL weight kg / km Outer Ø approx. mm AWG-No. No.cores x cross-sec. mm² Part no. Weight approx. kg / km AL weight kg / km Outer Ø approx. mm AWG-No. No.cores x cross-sec. mm² Part no. 379,0 206,0 17,4 - 1 x 70 707062 950,0 544,0 24,5 - 1 x 185 706088 480,0 280,0 18,8 - 1 x 95 707063 1150,0 706,0 27,5 - 1 x 240 706089 576,0 355,0 20,6 - 1 x 120 707064 1400,0 882,0 31,9 - 1 x 300 706084 665,0 441,0 22,4 - 1 x 150 706408 1680,0 1176,0 36,7 - 1 x 400 706085 Dimensions and specifications may be changed without prior notice.

Upload: others

Post on 04-Jun-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HELUWIND WK POWERLINE ALU 105°C, 0,6/1kV

HELUWIND® WK POWERLINE ALU 105°C, 0,6/1kVflexible ALU-Conductor

PropertiesCable structureTechnical dataAluminium conductor, fine stranded wiresTemperature range

fixed -40°C to +105°Cflexing -20°C up to +90°C

UV resistantoil-resistantSpecial insulation black

Sheath special compound easy to assembleOperating temperature at conductormax. +105°C

recyclableblack jacket

Nominal voltage 0,6/1kV (50Hz)

NotePlease ask for our extendednotes/informationabout the properties and for the necessaryconnection technology.Please contact us with your individualrequirements viafax +49 7150 9209 5135.

Test voltage2,5kV (50Hz)Min. bending radiusflexing 10 x cable outer diameterfixed installation 4 x cable outer diameterFlame testIEC 60332-1Approvalsacc. to DIN VDE 0250-813UL/CSA in preparation

ApplicationThe WK Powerline ALU is a highly flexible aluminum cable with a fine wire strand structure, which is suitable for use in the area of energymanagement - especially in the power wiring of a wind turbine. Thanks to its high flexibility and low weight, this cable can be installed inthe tower in one continuous length. Time-intensive wiring of the individual tower segments is eliminated.

The decisive advantage, however, lies in the process safety of the connection technology: The number of breaks from the top tower segmentto the inverter is reduced from as many as 90 connection points to only 18 connections, depending on the number of power cables andtower segments. The installation effort in the field is thereby reduced from several days to a few hours.

For torsional use we recommend the WK 103-T, WK 135-T or WK 137-T.

The WK Powerline ALU may only be prepared with the certified connection technology of HELUKABLE®. Either with the C8Crimp or screw connector (tested in accordance with IEC 61238-1 Cl. A). See Accessories section in the catalog.The cable is also optionally available in a halogen-free design with UL/CSA approval and a rated voltage of 1.8/3 kV.

= The product conforms to the EC Low Voltage Directive 2006/95/EC

Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no. Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no.

379,0206,017,4-1 x 70707062 950,0544,024,5-1 x 185706088480,0280,018,8-1 x 95707063 1150,0706,027,5-1 x 240706089576,0355,020,6-1 x 120707064 1400,0882,031,9-1 x 300706084665,0441,022,4-1 x 150706408 1680,01176,036,7-1 x 400706085

Dimensions and specifications may be changed without prior notice.

Page 2: HELUWIND WK POWERLINE ALU 105°C, 0,6/1kV

HELUWIND® WK POWERLINE ALU robust 105°C,0,6/1kVflexible ALU-Conductor

PropertiesCable structureTechnical dataAluminium conductor, fine stranded wiresTemperature range

fixed -40°C to +105°Cflexing -20°C up to +90°C

extremely abraison resistantUV resistantSpecial insulation black

Sheath special compound oil-resistantOperating temperature at conductormax. +105°C

easy to assembleblack jacketrecyclable

Nominal voltage 0,6/1kV (50Hz) NoteTest voltage2,5kV (50Hz)

Please ask for our extendednotes/informationabout the properties and for the necessaryconnection technology.Please contact us with your individualrequirements viafax +49 7150 9209 5135.

Min. bending radiusflexing 10 x cable outer diameterfixed installation 4 x cable outer diameterFlame testIEC 60332-1Approvalsacc. to DIN VDE 0250-813UL/CSA in preparation

Application

= The product conforms to the EC low-voltage directive 2006/95/EG.

Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no. Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no.

460,0206,017,4-1 x 70707097 950,0544,024,5-1 x 185707101536,0280,018,8-1 x 95707098 1150,0706,027,5-1 x 240707102576,0355,020,6-1 x 120707099 1398,0882,031,9-1 x 300707103665,0441,022,4-1 x 150707100 1588,01176,036,7-1 x 400707104

Dimensions and specifications may be changed without prior notice.

Page 3: HELUWIND WK POWERLINE ALU 105°C, 0,6/1kV

HELUWIND® WK POWERLINE ALU 105°C, 1,8/3kVflexible ALU-Conductor, direct burial

PropertiesCable structureTechnical dataAluminium conductor, fine stranded wiresTemperature range

fixed -40°C to +105°Cflexing -20°C up to +90°C

UV resistantoil-resistantSpecial insulation black

Jacket special compound easy to assembleOperating temperature at conductormax. +105°C

recyclableblack jacketdirect burial

Nominal voltage 1,8/3 kV (50Hz) NoteTest voltage9 kV (50Hz)

Please ask for our extendednotes/informationabout the properties and for the necessaryconnection technology.Please contact us with your individualrequirements viafax +49 7150 9209 5135.

Min. bending radiusflexing 10 x cable outer diameterfixed installation 4 x cable outer diameterFlame testIEC 60332-1Approvalsin accordance DIN VDE 0250-813

Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no. Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no.

1020,0544,026,0-1 x 185707647 1520,0882,033,2-1 x 3007074321250,0706,028,4-1 x 240706578 1855,01176,038,1-1 x 400707648

Dimensions and specifications may be changed without prior notice.

Page 4: HELUWIND WK POWERLINE ALU 105°C, 0,6/1kV

HELUWIND® WK POWERLINE ALU robust 105°C,1,8/3kVflexible ALU-Conductor

PropertiesCable structureTechnical dataAluminium conductor, fine stranded wiresTemperature range

fixed -40°C to +105°Cflexing -20°C up to +90°C

extremely abraison resistantUV resistantSpecial insulation black

Sheath special compound oil-resistantOperating temperature at conductormax. +105°C

easy to assembleblack jacketrecyclable

Nominal voltage 1,8/3kV (50Hz) NoteTest voltage9kV (50Hz)

Please ask for our extendednotes/informationabout the properties and for the necessaryconnection technology.Please contact us with your individualrequirements viafax +49 7150 9209 5135.

Min. bending radiusflexing 10 x cable outer diameterfixed installation 4 x cable outer diameterFlame testIEC 60332-1Approvalsin accordance DIN VDE 0250-813

Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no. Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no.

1020,0544,026,0-1 x 185707692 1520,0882,033,2-1 x 3007076941250,0706,028,4-1 x 240707693 1855,01176,038,1-1 x 400707695

Dimensions and specifications may be changed without prior notice.

Page 5: HELUWIND WK POWERLINE ALU 105°C, 0,6/1kV

HELUWIND ® WK POWERLINE ALU halogen free105°C 1,8/3kVflexible ALU-Conductor

PropertiesCable structureTechnical dataAluminium conductor, fine stranded wiresTemperature range

fixed -40°C to +105°Cflexing -20°C up to +90°C

halogen freeabraison resistantSpecial insulation black

Sheath special compound UV resistantOperating temperature at conductormax. +105°C

oil-resistantblack jacketeasy to assemble

Nominal voltage 1,8/3kV (50Hz)

recyclable

Test voltage9kV (50Hz)

NotePlease ask for our extendednotes/informationabout the properties and for the necessaryconnection technology.Please contact us with your individualrequirements viafax +49 7150 9209 5135.

Min. bending radiusflexing 10 x cable outer diameterfixed installation 4 x cable outer diameterApprovalsin accordance DIN VDE 0250-813

Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no. Weightapprox.kg / km

ALweightkg / km

Outer Øapprox.mm

AWG-No.No.cores xcross-sec.mm²

Part no.

1020,0544,026,0-1 x 185709143 1400,0882,033,2-1 x 3007091451150,0706,028,4-1 x 240709144 1680,01176,038,1-1 x 400709146

Dimensions and specifications may be changed without prior notice.