form 3 state of utah department of natural … · api number assigned 43013500330000 permit manager...

65
STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES DIVISION OF OIL, GAS AND MINING APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NUMBER Federal 10-21-8-16 2. TYPE OF WORK DRILL NEW WELL REENTER P&A WELL DEEPEN WELL 3. FIELD OR WILDCAT MONUMENT BUTTE 4. TYPE OF WELL Oil Well Coalbed Methane Well: NO 5. UNIT or COMMUNITIZATION AGREEMENT NAME 6. NAME OF OPERATOR NEWFIELD PRODUCTION COMPANY 7. OPERATOR PHONE 435 646-4825 8. ADDRESS OF OPERATOR Rt 3 Box 3630 , Myton, UT, 84052 9. OPERATOR E-MAIL [email protected] 10. MINERAL LEASE NUMBER (FEDERAL, INDIAN, OR STATE) UTU-69060 11. MINERAL OWNERSHIP FEDERAL INDIAN STATE FEE 12. SURFACE OWNERSHIP FEDERAL INDIAN STATE FEE 13. NAME OF SURFACE OWNER (if box 12 = 'fee') Henderson Ranches LLC 14. SURFACE OWNER PHONE (if box 12 = 'fee') 15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') Route 3 Box 3671, , 16. SURFACE OWNER E-MAIL (if box 12 = 'fee') 17. INDIAN ALLOTTEE OR TRIBE NAME (if box 12 = 'INDIAN') 18. INTEND TO COMMINGLE PRODUCTION FROM MULTIPLE FORMATIONS YES (Submit Commingling Application) NO 19. SLANT VERTICAL DIRECTIONAL HORIZONTAL 20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN LOCATION AT SURFACE 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S Top of Uppermost Producing Zone 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S At Total Depth 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S 21. COUNTY DUCHESNE 22. DISTANCE TO NEAREST LEASE LINE (Feet) 699 23. NUMBER OF ACRES IN DRILLING UNIT 40 25. DISTANCE TO NEAREST WELL IN SAME POOL (Applied For Drilling or Completed) 2005 26. PROPOSED DEPTH MD: 6690 TVD: 6690 27. ELEVATION - GROUND LEVEL 5450 28. BOND NUMBER WYB000493 29. SOURCE OF DRILLING WATER / WATER RIGHTS APPROVAL NUMBER IF APPLICABLE 43-7478 ATTACHMENTS VERIFY THE FOLLOWING ARE ATTACHED IN ACCORCANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY DRILLED) TOPOGRAPHICAL MAP NAME Mandie Crozier TITLE Regulatory Tech PHONE 435 646-4825 SIGNATURE DATE 05/19/2009 EMAIL [email protected] API NUMBER ASSIGNED 43013500330000 Permit Manager APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009 API Well No: 43013500330000 Received: 5/19/2009 FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES AMENDED REPORT DIVISION OF OIL, GAS AND MINING APPLICATION FOR PERMIT TO DRILL 1. WELL NAME andFeNdUeMa OR-21-8-16 2. TYPE OF WORK 3. FIELD OR WILDCAT DRILL NEW WELLI REENTER P&A WELL DEEPEN WELL I MONUMENT BUTTE 4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAME Oil Well Coalbed Methane Well: NO 6. NAME OF OPERATOR 7. OPERATOR PHONE NEWFIELD PRODUCTION COMPANY 435 646-4825 8. ADDRESS OF OPERATOR 9. OPERATOR E-MAIL Rt 3 Box 3630 , Myton, UT, 84052 [email protected] 10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP (FEDERAL, INDIAN, OR A69EO60 FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATE I FEEl 13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee') Henderson Ranches LLC 15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee') Route 3 Box 3671, , 17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT (if box 12 = 'INDIAN') MULTIPLE FORMATIONS YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I 20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN LOCATION AT SURFACE 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S Top of Uppermost Producing Zone 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S At Total Depth 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S 21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNIT DUCHESNE 699 40 25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH (Applied For Drilling or Completed) MD: 6690 TVD: 6690 2005 27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER / WATER RIGHTS APPROVAL NUMBER IF APPLICABLE 5450 WYBOOO493 43-7478 ATTACHMENTS VERIFY THE FOLLOWING ARE ATTACHED IN ACCORCANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP DRILLED) NAME Mandie Crozier TITLE Regulatory Tech PHONE 435 646-4825 SIGNATURE DATE 05/19/2009 EMAIL [email protected] API NUMBER ASSIGNED APPROVAL I 43013500330000 Permit

Upload: others

Post on 24-Jan-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS AND MINING

APPLICATION FOR PERMIT TO DRILL 1. WELL NAME and NUMBER

Federal 10-21-8-16

2. TYPE OF WORK

DRILL NEW WELL REENTER P&A WELL DEEPEN WELL 3. FIELD OR WILDCAT

MONUMENT BUTTE

4. TYPE OF WELLOil Well Coalbed Methane Well: NO

5. UNIT or COMMUNITIZATION AGREEMENT NAME

6. NAME OF OPERATORNEWFIELD PRODUCTION COMPANY

7. OPERATOR PHONE435 646-4825

8. ADDRESS OF OPERATORRt 3 Box 3630 , Myton, UT, 84052

9. OPERATOR [email protected]

10. MINERAL LEASE NUMBER(FEDERAL, INDIAN, OR STATE)

UTU-69060

11. MINERAL OWNERSHIP

FEDERAL INDIAN STATE FEE 12. SURFACE OWNERSHIP

FEDERAL INDIAN STATE FEE

13. NAME OF SURFACE OWNER (if box 12 = 'fee')Henderson Ranches LLC

14. SURFACE OWNER PHONE (if box 12 = 'fee')

15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee')Route 3 Box 3671, ,

16. SURFACE OWNER E-MAIL (if box 12 = 'fee')

17. INDIAN ALLOTTEE OR TRIBE NAME(if box 12 = 'INDIAN')

18. INTEND TO COMMINGLE PRODUCTION FROMMULTIPLE FORMATIONS

YES (Submit Commingling Application) NO

19. SLANT

VERTICAL DIRECTIONAL HORIZONTAL

20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN

LOCATION AT SURFACE 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S

Top of Uppermost Producing Zone 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S

At Total Depth 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S

21. COUNTYDUCHESNE

22. DISTANCE TO NEAREST LEASE LINE (Feet)699

23. NUMBER OF ACRES IN DRILLING UNIT40

25. DISTANCE TO NEAREST WELL IN SAME POOL(Applied For Drilling or Completed)

2005

26. PROPOSED DEPTHMD: 6690 TVD: 6690

27. ELEVATION - GROUND LEVEL

5450

28. BOND NUMBER

WYB000493

29. SOURCE OF DRILLING WATER /WATER RIGHTS APPROVAL NUMBER IF APPLICABLE

43-7478

ATTACHMENTS

VERIFY THE FOLLOWING ARE ATTACHED IN ACCORCANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES

WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN

AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER

DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY

DRILLED)

TOPOGRAPHICAL MAP

NAME Mandie Crozier TITLE Regulatory Tech PHONE 435 646-4825

SIGNATURE DATE 05/19/2009 EMAIL [email protected]

API NUMBER ASSIGNED

43013500330000

Permit Manager

APPROVAL

FORM 3

AMENDED REPORT

API Well No: 43013500330000 Received: 5/19/2009API Well No: 43013500330000 Received: 5/19/2009

FORM 3STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCES AMENDED REPORTDIVISION OF OIL, GAS AND MINING

APPLICATION FOR PERMIT TO DRILL 1. WELL NAME andFeNdUeMa OR-21-8-16

2. TYPE OF WORK 3. FIELD OR WILDCATDRILL NEW WELLI REENTER P&A WELL DEEPEN WELL I MONUMENT BUTTE

4. TYPE OF WELL 5. UNIT or COMMUNITIZATION AGREEMENT NAMEOil Well Coalbed Methane Well: NO

6. NAME OF OPERATOR 7. OPERATOR PHONENEWFIELD PRODUCTION COMPANY 435 646-4825

8. ADDRESS OF OPERATOR 9. OPERATOR E-MAILRt 3 Box 3630 , Myton, UT, 84052 [email protected]

10. MINERAL LEASE NUMBER 11. MINERAL OWNERSHIP 12. SURFACE OWNERSHIP(FEDERAL, INDIAN, OR A69EO60

FEDERAL I INDIAN I STATE FEE FEDERAL INDIAN STATE I FEEl

13. NAME OF SURFACE OWNER (if box 12 = 'fee') 14. SURFACE OWNER PHONE (if box 12 = 'fee')Henderson Ranches LLC

15. ADDRESS OF SURFACE OWNER (if box 12 = 'fee') 16. SURFACE OWNER E-MAIL (if box 12 = 'fee')Route 3 Box 3671, ,

17. INDIAN ALLOTTEE OR TRIBE NAME 18. INTEND TO COMMINGLE PRODUCTION FROM 19. SLANT

(if box 12 = 'INDIAN')MULTIPLE FORMATIONS

YES (Submit Commingling Application) NO VERTICAL DIRECTIONAL HORIZONTAL I

20. LOCATION OF WELL FOOTAGES QTR-QTR SECTION TOWNSHIP RANGE MERIDIAN

LOCATION AT SURFACE 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S

Top of Uppermost Producing Zone 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S

At Total Depth 2090 FSL 1941 FEL NWSE 21 8.0 S 16.0 E S

21. COUNTY 22. DISTANCE TO NEAREST LEASE LINE (Feet) 23. NUMBER OF ACRES IN DRILLING UNITDUCHESNE 699 40

25. DISTANCE TO NEAREST WELL IN SAME POOL 26. PROPOSED DEPTH(Applied For Drilling or Completed) MD: 6690 TVD: 66902005

27. ELEVATION - GROUND LEVEL 28. BOND NUMBER 29. SOURCE OF DRILLING WATER /WATER RIGHTS APPROVAL NUMBER IF APPLICABLE

5450 WYBOOO493 43-7478

ATTACHMENTS

VERIFY THE FOLLOWING ARE ATTACHED IN ACCORCANCE WITH THE UTAH OIL AND GAS CONSERVATION GENERAL RULES

WELL PLAT OR MAP PREPARED BY LICENSED SURVEYOR OR ENGINEER COMPLETE DRILLING PLAN

AFFIDAVIT OF STATUS OF SURFACE OWNER AGREEMENT (IF FEE SURFACE) FORM 5. IF OPERATOR IS OTHER THAN THE LEASE OWNER

DIRECTIONAL SURVEY PLAN (IF DIRECTIONALLY OR HORIZONTALLY TOPOGRAPHICAL MAP

DRILLED)

NAME Mandie Crozier TITLE Regulatory Tech PHONE 435 646-4825

SIGNATURE DATE 05/19/2009 EMAIL [email protected]

API NUMBER ASSIGNED APPROVAL I

43013500330000

Permit

Page 2: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Prod 7.875 5.5 0 6690

Pipe Grade Length Weight

Grade J-55 LT&C 6690 15.5

API Well No: 43013500330000 Received: 5/19/2009API Well No: 43013500330000 Received: 5/19/2009

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Prod 7.875 5.5 0 6690

Pipe Grade Length Weight

Grade J-55 LT&C 6690

Page 3: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Surf 12.25 8.625 0 350

Pipe Grade Length Weight

Grade J-55 ST&C 350 24.0

API Well No: 43013500330000 Received: 5/19/2009API Well No: 43013500330000 Received: 5/19/2009

Proposed Hole, Casing, and Cement

String Hole Size Casing Size Top (MD) Bottom (MD)

Surf 12.25 8.625 0 350

Pipe Grade Length Weight

Grade J-55 ST&C 350

Page 4: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’CD

T8S,

Ri B

E,S.

L.B

. &M

.N

EN'IE

LDPR

ON

CI'I

ON C

OX

PMyp

AR

a-w

---"

¯NW

ELL

LOC

ATI

ON

,FE

DER

AL

10-2

1--8

-16,

yB57

(Me°

'LO

CA

TED

AS

SHO

WN

INTH

EN

W1/

4SE

OL

800

yda

.-L

8&

MSE

DC

UT

OH

N2N

1EC

OSU

NR

EUTA

H.

LOT

157

4'4

yeas

oO

o2.

96'

(/

oo

o26

3LO

T2

---

---

-

LOT

3LO

T4

BA

RSC

ALE

ifELL

LOC

A71

0W:

FED

ERA

L10

-21-

8-16

iN

otes

:1.

The

foot

ages

are

rnea

sure

dEL

EXU

NG

RA

DED

GR

OU

ND

=54

49.9

;pyp

perp

endi

cula

rto

sect

ion

line.

Bra

ssc«

po

2.Th

ePr

opos

edW

ell

head

bear

s$7

353

'02"

W20

20.0

9'fr

omth

eig

7pEa

st1/

4C

orne

rof

Sect

ion

21.

THIS

ISTO

CER

TIFY

THA

Ag

WA

SPR

EPA

RED

FRO

MFI

ELD

FA

g,V

EYS

MA

DE

BY

ME

OR

UN

WTH

AT

THE

SAM

EA

RE

TRU

AA

iR

REC

TT

HT

OF

MY

KN

OW

LED

GE

AN

gi.N

o.18

9377

gST

AC

YW

.

Isto

isto

ISE

DN

L

scos

s cop

Bra

ssco

par

ms

cap

S39'

47'1

8"W

-

2637

03'

(Mea

s)

SB9

50'5

5"W

-

2609

.77'

(Mea

s.)TR

I STA

TELA

ND

SUR

V EY

ING

&C

ON

SULT

ING

589

50'W

-

79.9

0(G

.L.O

.)18

0N

OR

THV

ERN

AL

AV

E.-

VER

NA

L,U

TAH

8407

8(4

35)

781-

2501

\FED

ERA

L10

-21-

8-16

DA

TESU

RV

EYED

:=

SEC

TIO

NC

OR

NER

SLO

CA

TED

(Sur

face

Loco

tlan)

NA

DB

J01

-20-

09SU

RV

EYED

BY

:D

.G.

LA7/

TUD

E=

40'

0607

01"

DA

TED

RA

WN

:D

RA

WN

BY

:M

.WB

ASI

SO

FEL

EV;

LON

GIT

UD

E-

110°

07'

19.2

9"01

-27-

09U

.S.G

.S.

7-1/

2m

inQ

UA

D(M

YTO

NSE

)"E

Y'

SCA

LE:

1"=

Page 5: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

NEWFIELD PRODUCTION COMPANYFEDERAL 10-21-8-16

NW/SE SECTION 21, TSS, R16EDUCHESNE COUNTY, UTAH

ONSHORE ORDER NO. 1

DRILLING PROGRAM

1. GEOLOGIC SURFACE FORH4 TION:

Uinta formation of Upper Eocene Age

2. ESTIMATED TOPS OF IMPORTANT GEOLOGIC MARKERS:

Uinta 0' - 1832'Green River 1832'Wasatch 6690'Base of Moderately Saline Ground Water @352'

3. ESTIMATED DEPTHS OF ANTICIPATED WATER, OIL, GAS OR MINERALS:

Green River Formation 1832' - 6690' - Oil

4. PROPOSED CASING PROGRAM

Please refer to the Monument Butte Field Standard Operation Procedure (SOP).

5. MINIMUM SPECIFICATIONS FOR PRESSURE CONTROL:

Please refer to the Monument Butte Field SOP. See Exhibit "C".

6. TYPE AND CHARACTERISTICS OF THE PROPOSED CIRCULATION MUDS:

Please refer to the Monument Butte Field SOP.

7. AUXILIARY SAFETY EQUIPMENT TO BE USED:

Please refer to the Monument Butte Field SOP.

8. TESTING, LOGGING AND CORING PROGRAMS:

Please refer to the Monument Butte Field SOP.

9. ANTICIPATED ABNORH4L PRESSURE OR TEMPERATURE:

The anticipated maximum bottom hole pressure is 1800 psi. It is not anticipated that abnormaltemperatures will be encountered.

10. ANTICIPATED STARTING DATE AND DURATION OF THE OPERATIONS:

Please refer to the Monument Butte Field

Page 6: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000' 2-M SYSTEMBlowout Prevention Equipment Systems

s

EXHIBIT

Page 7: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

Brklgelatud

enIr

I

LLE

04mL) •\

0.3 mL )

See Topo ''8"0.5 mL ) Proposed Location

Federal10-21

L . 1 A

C

LegendExisting Road

..dra'Seryg Proposed Access\ (436) 781-2501180 Nords Vernal Ave. Vamal, Ulah ß4078Federal 10-21-8-16

, ... . - - -- -

SEC.21,TSS, Ri6E, S.L.B.&M. -...- "- "A"& $

Page 8: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

.-

I † ||l-|9ñr

0.5 mi.] *910'Proposed Location

Federal 10-21

e. I

I

Legendgas Existing Road

Adf y fx - Proposed Access(435)781-2501

180 North Wrnd Ave Vornal, Ulah 84078

Federal 10-21-8-16. ·•• - -

SEC. 21, TBS, R16E, S.L.B.&M. - 3 " 'g'•t i .

Page 9: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

Tle in at ExistingGas PipelineI

Tle in at Existing910 Waterline

±910'Proposed Location

Federal 10-21

|

Legend -

.. Roads- Proposed Gas Urte

--m==-I Proposed Water Line(435) 781-2501180 Nor Va alAve. Vernal Lheb 84078

Federal 10-21-8-16.

- .. - - -

SEC.21,T8S, R16E, S.L.B.&M. "- - " "g"E I

Page 10: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’

Loca

tion

-

Surf

ace

Spud

9to

1011

7a

elo

11Il

Dril

ling

Wai

ting

onC

ompl

etio

nPr

oduc

ing

Oil

Wel

l-

Prod

ucin

gG

asW

ell

1716

a17

1&1;

lala

la17

141

laim

Wat

erin

ject

ion

Wel

-D

ryH

ole

Tem

pora

rily

Aba

ndon

ed-

Plug

ged

8A

band

oned

3Dat

ya

9,4

,la

A34

in40

-1n

sa/

Shut

in

,ß.

AA

93.

,_A

/W

ater

Sour

ceW

ell

Wte

rDis

posa

lW

ell

zitu

assa |

NEW

FIEL

D

RO

CK

YM

OU

NTA

INS

-_

Exhi

bitA

Due

box

&U

muh

Cou

nue

}12

76

127

1017

12

Iit

Iis

ni

to--

Page 11: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

g g[9 I 19 8 19 * JU A JO JO my ' JL o ' JO Al 50 * f

, 10 .LI 21

11 10 11 10 ru lo 9 10 20 9 10 1/ ld l a

MI e 29 I

T 76561 TV 748• I

e 11 ; ¿ e ro

I wkevero i ro 20 ao

, .. Proposed Locat >> a oI'TlL773 9 Federal10-21

ro I Jo 14 y , 11 4 11 I IJ 16

9 1 TI 77339 I

L g are 29 18 41 274 11 d; gr

l'ravis *nåte e e a e eI; ;9 I) ;9 9 9 59 IT1|I Il 28 9 B IJ 17 ¡¡ J

SL-07 t S72A· 11, - 26026.O O A 2. e e

tah JEWells I)gaw I Ig 'nit Monurne ie ese'egi 4 37 ) 5) J 91 1 21 ) 15 4 14 i b-0 2 to

M I,-21836 * 6 " "

Legend

LocationAgw4'Ser Ñrt O One-Mile Radius

\ (436) 781-2501r 180 Norill Vemal Ave Vomal. IJtub 84078

Federal 10-21-8-16 '. ...

SEC. 21, TSS, R16E, S.L.B.&M.

Page 12: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

NEWFIELD PRODUCTION COMPANYFEDERAL 10-21-8-16

Section 21, TBS, Ri6E, S.L.B.&M.

PROPOSED ACCESS /ROAD (Max. 6% Grade)

STA. 3+00

PIT ÖPSo/L ..

srocx tr .

/ S/opeSTA. 2+30

Top off swm Around rig - Cut Slope

120' •29

STA. 1+70

C/2. 7LARE

14ELL HEAD: Fir

UNGRAOED = 5449.9' N_oteEIN GRADE = 5448.0' E/ore pit /s to

· be /ocated aminimum of 80'EXCESS from well head.

STA 0+00 •

: srocxP/LE REFERENCE POINTS220' WESTERLY - 5451.2'270' WESTERLY - 5451.9'170' NORTHERLY - 5446.1'220' NORTHERLY - 5445.3'

SURVEYED BY: D.G, DATE SURVEYED: 01-20-09 i State 6""""'-2DRAWN BY: M.W. DATE DRAWN: 01-27-09 La,nd Surveying, Inc.SCALE: 1" = 50' REVISED: \ 180 NORTH VERNAL AVE. VERNAL, UTAH

Page 13: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

NEWFIELD PRODUCTION COMPANYCROSS SECTIONS

FEDERAL 10-21- 8-16

50' S M. 3+ 00

so' SM. 2+JO

EX/977NGF/N/SHED GRADEGRADE

-

WELL HEAD

so SM. 1+70

Y - so' SM. 0+00 ESTIMATEDEARTHWORKQUANTITIES(No Shrink or swell adjustments have been used)

(Expressed in Cubic Yards)ITEM CUT FILL 6" TOPSOIL EXCESS

NOTE: PAD 1,780 1,780 ToPsoil is OUNLESS OTHERWISE not includedNOTED ALL CUT/FILL PIT 640 0 in Pad cut 640SLOPES ARE AT 1.5:1 TOTALS 2,420 1,780 990 640

SURVEYED BY: D.G. DATE SURVEYED: 01-20-09 ri State """"'¯26 'DRAWN BY: M.W. DATE DRAWN: 01-27-09 Land Surveying, Inc.SCALE: 1" = 50' REVISED: s 180 NORTH VERNAL AVE. VERNAL, UTAH

Page 14: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

NEWFIELD PRODUCTION COMPANYTYPICAL RIG LAYOUT

FEDERAL 10-21-8-16

PROPOSED ACCESSROAD (Mox 6% Grade)

Emergency fuelSTORAGE shut downTANK r- ¯¯·-

---¯¯--i---

i -> o ,

RES VEP/T

¯- 120' --- 29 - (8' D'*PA-

îllikPIPE RACKS

¯EpiRE

PIPE RACKS ec.

I

SURVEYED BY: D.G. DATE SURVEYED: 01-20-09(4]S) 7ôl-2501

DRAWN BY: M.W. DATE DRAWN: 01-27-09 Land Surveying, Inc.SCALE: 1" = 50' REV\SED: > 180 NORTH VERNAL AVE. VERNAL, UTAH

Page 15: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

NEWFIELD PRODUCTION COMPANYFEDERAL 10-21-8-16

NWISE SECTION 21, T8S, R16EDUCHESNE COUNTY, UTAH

ONSHORE ORDER NO. 1

MULTI-POINT SURFACE USE & OPERATIONS PLAN

1. EXISTING ROADS

See attached Topographic Map "A"

To reach Newfield Production Company well location site Federal 10-21-8-16 located in the NW1/4 SE 1/4 Section 21, T8S, Rl6E, Duchesne County, Utah:

Proceed southwesterly out of Myton, Utah along Highway 40 - 1.4 miles ± to the junctionof thishighway and UT State Hwy 53; proceed southwesterly - 6.6 miles ± to it's junctionwith anexisting road to the east; proceed in an easterly direction - 0.5 miles ± to it's junctionwith anexisting road to the northeast; proceed northeasterly - 0.4 miles ± to ti's junctionwith an existingroad to the southeast; proceed southeasterly - 0.3 miles ± to it's junctionwith the beginning of theproposed access road; continue in a westerly direction along the proposed access road -910' ±tothe proposed well location.

2. PLANNED ACCESS ROAD

See Topographic Map "B" for the location of the proposed access road.

3. LOCATION OF EXISTING WELLS

Refer to Exhibit "B".

4. LOCATION OF EXISTING AND/OR PROPOSED FACILITIES

All permanent surface equipment will be painted Carlsbad Canyon.Please refer to the Monument Butte Field Standard Operating Procedure (SOP).

5. LOCATION AND TYPE OF WATER SUPPLY

Newfield Production will transport water by truck for drilling purposes from the following watersources:

Johnson Water DistrictWater Right : 43-7478

Neil Moon PondWater Right: 43-11787

Maurice Harvey PondWater Right: 47-1358

Newfield Collector WellWater Right: 41-3530 (A30414DV, contracted with the Duchesne County Conservancy District).

Please refer to the Monument Butte Field SOP. See Exhibit

Page 16: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

6. SOURCE OF CONSTRUCTIONMATERL4LS

Please refer to the Monument Butte Field SOP.

7. METHODS FOR HANDLING WASTE DISPOSAL

Please refer to the Monument Butte Field SOP.

8. ANCILLARY FACILITIES

Please refer to the Monument Butte Field SOP.

9. WELL SITE LAYOUT

See attached Location Layout Diagram.

10. PLANS FOR RESTORATION OF SURFACE

Please refer to the Monument Butte Field SOP.

11. SURFACE OWNERSHIP - Bureau Of Land Management (Proposed location and access roads

leading to).

12. OTHER ADDITIONAL INFORMATION

The Archaeological Resource Survey and Paleontological Resource Survey for this area are

attached. MOAC Report #08-295, 2/5/09. Paleontological Resource Survey prepared by, WadeE. Miller, 5/1/08. See attached report cover pages, Exhibit "D".

Newfield Production Company requests 910' of disturbed area be granted in Lease UTU-69060 toallow for construction of the planned access road. Refer to Topographic Map "B". Apermanent width of 30' and a running surface of 18' is proposed for the planned access road. Theconstruction phase of the planned access road will last approximately (5) days. The plannedaccess road will be an 18' crown road (9' either side of the centerline) with drainage ditches alongeither side of the proposed road whether it is deemed necessary in order to handle any run-off fromnormal meteorological conditions that are prevalent to this area. The maximum grade will be lessthan 8%. There will be no culverts required along this access road. There will be barrow ditchesand turnouts as needed along this road. There are no fences encountered along this proposed road.There will be no new gates or cattle guards required. All construction material for this access roadwill be borrowed material accumulated during construction of the access road.

Newfield Production Company requests 910' of disturbed area be granted in Lease UTU-69060 toallow for construction of the proposed surface gas lines. It is proposed that the disturbed area willtemporarily be 50' wide to allow for construction of a 10" or smaller gas gathering line, and a 3"poly fuel gas line, with a permanent width of 30' upon completion of the proposed gas lines. Theconstruction phase of the proposed gas lines will last approximately (5) days. Both lines will tie into the existing pipeline infrastructure. Refer to Topographic Map "C." For a ROW plan ofdevelopment, please refer to the Monument Butte Field SOP.

Newfield Production Company requests 910' of disturbed area be granted in Lease UTU-69060 toallow for construction of the proposed water lines. It is proposed that the disturbed area willtemporarily be 50' wide to allow for construction of a buried 3" steel water injection line and aburied 3" poly water return line, with a permanent width of 30' upon completion of the proposedwater return line. The construction phase of the proposed water lines will last approximately (5)days. Refer to Topographic Map "C." For a ROW plan of development, please refer to theMonument Butte Field SOP. In the event that the proposed well is converted to a water injectionwell, a separate injection permit will be applied for through the proper agencies.

Page 17: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

Water DisposalImmediately upon first production, all produced water will be confined to a steel storage tank. Ifthe production water meets quality guidelines, it is transported to the Ashley, Monument Butte,Jonah, and Beluga water injection facilities by company or contract trucks. Subsequently, theproduced water is injected into approved Class II wells to enhance Newfield's secondary recoveryproject.

Water not meeting quality criteria, is disposed at Newfield's Pariette #4 disposal well (Sec. 7, T9SRl9E), State of Utah approved surface disposal facilities, or Federally approved surface disposalfacilities.

Threatened, Endangered, And Other Sensitive SpeciesMountain Plover: If new construction or surface disturbing activities are scheduled to occurbetween May 15 and June 15, detailed surveys of the area within 0.5 mile of the proposed locationand within 300 feet of proposed access routes must be conducted to detect the presence of mountainplovers. All surveys must be conducted in accordance with the survey protocols outlined in the mostrecent USFWS Survey Protocol. Surveys must be completed prior to initiating new construction orsurface disturbing activities. No new construction or surface disturbing activities will be allowedbetween May 15 and June 15 within a 0.5 mile radius of any documentedmountain plover nest site.

Burrowing Owl: Due to the proximity of the location to active prairie dog towns, there is thepotential to encounter nesting burrowing owls betweenApril 1 and August 15. If new construction orsurface disturbing activities are scheduled between April 1 and August 15, pre-construction surveyswill be conducted to detect the presence of nesting burrowing owls within 0.5 mile of any newconstruction or surface disturbing activity (see Vernal BLM Field Office Protocol). No newconstruction or surface disturbing activities will be allowed between April 1 and August 15 within a0.5 mile radius of any active burrowing owl nest.

Reserve Pit LinerA 16 mil liner with felt is required. Please refer to the Monument Butte Field SOP.

Location and Reserve Pit ReclamationPlease refer to the Monument Butte Field SOP.

The following seed mixture will be used on the topsoil stockpile, to the recontoured surface of thereserve pit, and for fmal reclamation: (All poundages are in pure live seed)

Squirrell Tail Elymus Elymoides 6 lbs/acreSiberian Wheatgrass Agropyron Fragile 2 lbs/acreGardner Saltbush Atriplex Gardneri I lbs/acreShadscale Atriplex Confertifolia 1 lbs/acreFourwing Saltbush Atriplex Canescens ] lbs/acreScarlet Globemallow Sphaeralcea Conccinea 0.20 lbs/acreForage Kochia Kochia Prostrata 0.20 lbs/acre

Details of the On-Site InspectionThe proposed Federal 10-21-8-16 was on-sited on 3/12/09. The following were present; TimEaton (Newfield Production ), Brian Foote (Newfield Production ), Christine Cimiluca (Bureau ofLand Management), and James Herford (Bureau of Land Management). Weather conditions wereclear and ground cover was 100% open.

LESSEE'S OR OPERATORS REPRESENTATIVE AND CERTIFICATION

Representative

Name: Dave Allred

Page 18: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

Address: Route #3 Box 3630Myton, UT 84052

Telephone: (435) 646-3721

Certification

Please be advised that NEWFIELD PRODUCTION COMPANY is considered to be theoperator of well #10-21-8-16 NW/SE Section 21, Township 8S, Range 16E: Lease UTU-69060Duchesne County, Utah: and is responsible under the terms and conditions of the lease for theoperations conducted upon the leased lands. Bond coverage is provided by, Federal Bond#WYBOOO493.

I hereby certify that the proposed drill site and access route have been inspected, and Iam familiar with the conditions which currently exist; that the statements made in this plan are trueand correct to the best of my knowledge; and that the work associated with the operationsproposed here will be performed by Newfield Production Company and its contractors andsubcontractors in conformity with this plan and the terms and conditions under which it isapproved. This statement is subject to the provisions of 18 U.S.C. 1001 for the filing of a falsestatement.

Date Mandie CrozierRegulatory SpecialistNewfield Production Company

Page 19: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

Newfield Production CompanyProposed Site Facility Diagram

Federal 10-21-8-16

NW/SE Sec. 21, T8S, R16E

Duchesne County, Utah

UTU-69060

Wen Head 55 Gallons.

Methonol

Puniping Unit 150 Gallons LegendChemical Drums

Emulsion Line ······

Load Rack -----------

55 GallonsWater Line --· -· --· --· ---

MotorOil licater GasSales -- --· --··--··

Treater Oil Line

Gas Sales Meter.

I

Water Tank 6 - · -- ' -

200 bbl I Production Phase:I 1) Valves 1, 3, and 4 sealed closedI

2) Valves 2, 5, and 6 sealed open

I2

Sales Phase:4 Production Tank 3 - - 4 - - - - - - - - _ _

Load Rack

1) Valves 1, 2, 4, 5, and 6 sealed closed400 bbl 1 --. I

I | 2) Valve 3 openI

5Draining Phase:

2 1) Valves 1 and 6 open

Production Tank4

400bbl3 --U

l -·JDiked

Page 20: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’'APIWellNo:43013500330000'

CULTURAL RESOURCE INVENTORY OF o ONEWFIELD EXPLORATION'S THREE BLOCK PARCELS

(T8S, R16E, SECTIONS 21, 22 AND 23)DUCHESNECOUNTY,UTAH

By:

Nicole Shelnut

Prepared For:

Bureau of Land ManagementVernal Field Office

Prepared Under Contract With:

Newfield Exploration CompanyRt. 3 Box 3630

Myton, UT 84052

Prepared By:

Montgomery Archaeological Consultants, Inc.P.O. Box 219

Moab, Utah 84532

MOAC Report No. 08-295

February 5, 2009

United States Department of Interior (FLPMA)Permit No. 08-UT-60122

State of Utah Antiquities Project (Survey)Permit No.

Page 21: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

’APIWellNo:43013500330000’' PIWellNo:43013500330000'

NEWFIELD EXPLORATION COMPANY

li

PALEONTOLOGICAL SURVEY OF PROPOSEDPRODUCTION DEVELOPMENT AREAS,

DUCHESNE & DINTAB COUNTIES, UTAH

I Section 21, T 8 S, R 16 E [Entire section excluding NE/NW (3-21) & NW/NW(4-21)];

i Section 20, T 8 S, R 16 E [SW/NE (7-20), SE/NE (8-20), NE/SE (9-20), NW/SE (10-20),NE/SW (11-20), NW/SW (12-20), SW/SW (13-20), SE/SW (14-20), & SW/SE (15-20);

SE/SE, Section 32, T 8 S, R 18 E (16-32-8-18), NE/NE, Section 36, T 8 S, R 17 E (1-36-8-17),

i NE/NW & SW/NW, Section 18, T 9 S, R 19 E (3 & 5-18-9-19), and Proposed Water InjectionLine at SE/SW, Section 1, T 9 S, R 15 E (14-1-9-15).

IREPORT OF SURVEY

Prepared for:

Newfield Exploration Company

Prepared by:

I Wade E. MillerConsulting PaleontologistApril 30 & May 1, 2008

I

Page 22: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

ª

ª

·

ª

·

ª

N

'N N

N

ª

¸ªN

N

¸

N

NN

'

ª

'

'

''

''

'

'

'

'

H

H

H

G

G

G

G

G

G

G

G

G

GG

G

G

G

GG

M O N U M E N T B U T T E F I E L DM O N U M E N T B U T T E F I E L D

P L E A S A N T V A L L E Y F I E L DP L E A S A N T V A L L E Y F I E L D

H A W K E Y E ( G R ) U N I TH A W K E Y E ( G R ) U N I T

T R A V I S U N I TT R A V I S U N I T

F E N C E L I N E U N I TF E N C E L I N E U N I T

22

21

272829

29

20

20 21 22

28

30

19

15

23

14

26

27

4301316208JENSEN 1

4301310387FEDERAL 1

4301330705FEDERAL 3-28

4301350008Moon 1-20-4-2

4301350007Moon 3-20-4-2

4301350006Moon 1-29-4-2

4301350005Moon 3-29-4-2

4301350004Moon 4-29-4-2

4301350003Moon 2-29-4-2

4301350002Moon 4-20-4-2

4301350001Moon 2-20-4-2

4301316207LAMBERT FED 1

4301330394PLEASANT VLY 1

4301310007(2) JENSEN A-1

4301331941TRAVIS FED 9-28

4301350032Federal 8-21-8-16

4301350031Federal 6-21-8-16

4301350030Federal 2-21-8-16

4301350025Federal 1-21-8-16

4301334178FEDERAL 2-29-8-16

4301334177FEDERAL 3-29-8-16

4301334174FEDERAL 6-29-8-16

4301334000FEDERAL 5-21-8-16

4301333997FEDERAL 7-20-8-16

4301333995FEDERAL 8-20-8-16

4301332334TRAVIS 12-28-8-16

4301332333TRAVIS 11-28-8-16

4301350034Federal 11-21-8-16

4301350033Federal 10-21-8-16

4301350029Federal 14-21-8-16

4301350028Federal 15-21-8-16

4301334173FEDERAL 11-29-8-16

4301333999FEDERAL 12-21-8-16

4301333998FEDERAL 13-21-8-16

4301333996FEDERAL 10-20-8-16

4301333994FEDERAL 11-20-8-16

4301333991FEDERAL 14-20-8-16

4301333990FEDERAL 15-20-8-16

4301332474FEDERAL 16-20-8-16

4301334241UTE TRIBAL 9-19-4-2

4301334211UTE TRIBAL 1-30-4-2

4301333634UTE TRIBAL 8-30-4-2

4301332123UTE TRIBAL 8-30-4-2

4301330856WEST MONUMENT 10-28

4301334036UTE TRIBAL 14-21-4-2

4301334035UTE TRIBAL 15-21-4-2

4301334034UTE TRIBAL 16-21-4-2

4301333946UTE TRIBAL 16-19-4-2

4301333890UTE TRIBAL 14-22-4-2

4301333636UTE TRIBAL 13-22-4-2

4301331904N MON BUTTE FED 9-27

4301331062W MONUMENT FED 11-28

4301330771WELLS DRAW FED 27-42

4301330865W MONUMENT BUTTE 9-28

4301330996PLEASANT VLY FED 12-27

4301331919MONUMENT BUTTE FED 12-27

4301331903N MONUMENT BUTTE FED 8-27

4301331905N MONUMENT BUTTE FED 10-27

Map Produced by Diana MasonMap Prepared:

Well Name: Federal 10-21-8-16API Number: 4301350033

Township 08.0 S Section 21Range 16.0 EMeridian: SLBM

F1,500 0 1,500750 Feet

1:15,543

UnitsSTATUS

ACTIVE

EXPLORATORY

GAS STORAGE

NF PP OIL

NF SECONDARY

PI OIL

PP GAS

PP GEOTHERML

PP OIL

SECONDARY

TERMINATED

FieldsSTATUS

ACTIVE

COMBINED

Sections

Wells Query Events

D <all other values>

GIS_STAT_TYPE

" <Null>

APD

H DRL

4 GI

!* GS

N LA

G NEW

7 OPS

ª PA

* PGW

' POW

O RET

¸ SGW

· SOW

6 TA

" TW

¸ WD

¸ WI

=* WS

Tooele

Millard

Iron

San Juan

Kane

Juab

Uintah

Box Elder

Emery

Garfield

Grand

Utah

Beaver Wayne

Duchesne

Sevier

Summit

Rich

Washington

Carbon

Sanpete

Cache

Piute

Davis

Wasatch

Weber

DaggettSalt Lake

Morgan

Location Map

Operator: NEWFIELD PRODUCTION COMPANY

’APIW

ellNo:43013500330000’

+M430n 520000472 M430n1 20000422 API Number: 4301350033UTE43RO13A3L4 119-4- Well Name: Federal 10-21-8-16

Township 08.0 S Range 16.0 E Section 21M430n1 20000482

430135

00143013 4 36 4301334035 4 0 333636 Meridian: SLBM

Moon2-20-4-2 UTETRIBAL14-21-4-2 UTETRIBAL15-21-42 UTETRIBAL13-3 43323890 Operator: NEWFIELD PRODUCTION COMPANY

UTET4 316

9-4- UTET4 106

1-4- UTE TRIBAL 14-22-4-2

Map Prepared:27 Map Produced by Diana Mason

4301334211 4301350004 14UTE TR BAL 1-30-4-M430n1 20900452

Moon 4-29-4-2 28 15

29 4301350030 NFsscoNo

Federal224136 Piol'

4301350006 43 1350025PPGAs

30 4301 2123 Moon1-29-4-2 4301350003 Federal1-21-8-1 FENCEL I NEUN IT43

36ETRIB L 8-30-4-2 Moon 2-29-4-2

c NoARY w

UTETRIBAL8-30-4-4301350032

TERMiNATeo . OP

4301316208Fedeml 8-21-8-1

4301333995 4301334000 JENSEN 1 AcTive

FEDERAL 8-20-8-16 FEDERALS-21-8-16

4301350031

coM so

4301333997 , Federal 6-21-8-16 3 sawFEDERAL 7-20-8-16 + 14

4301333999Fed4e3r -0201

8-1621Fed4e

I050201

-16 4301310007 PLE A S A NT VA LLEY F I ELDFED RL

1392048-16 FEDERAL 12-21-8-16 + (2) JENSEN A-

4301333996FEDERAL 10-20-8-16

20

4301333998 43013303944301333990 FEDERAL13-21-8-16 4301350029 4301350028 PLEASANTVLY 4301316207

4301333991 FEDERAL15-20-8-16 Federal14-21-8-16 Federal15-21-8-16 LAMBERTFED 1BoxElder

cache Location MapFEDERAL 14-20-8-16

WeberRich

4301332474 vis Aor i

FEDERAL 16-20-8-16 summi Daalt Lak

Taœ\e

MONUMENT BUTTE F I ELD SatC DuchesnUintah

4301334177 4301334178 4301310387FEDERAL 3-29-8-16 FEDERAL 2-29-8-16 þDERAL 1 Juab

4301330705 Carbon

FEDERAL 3-28

H A WKEYE ( GR ) UN IT

rdSan te

Emery Grand

FED4E36 2 - 6

284WEL3LS

OORD 2

Beaver Piute

n JuanN MONUMENT BUTTE FED 8-27

Washington Kane *

TRAVIS UNIT4101330865 4301331905 4301331904

FEDROA1L3 2938-16 4301332334 4301332333 WMONU v1ENT BUTTg9-28 N MONUMENT BUTTE FED 10-27N MON BUTTE FED 9-27 :As

TRAVIS 12-28-8-16 XTRAVIS 11-28-8-16 4301330996X 4301331062 X 4301331941 PLEASANT VLY FED 12/27

WMONUMENT FED 11-28 TRAVIS FED 9-28 43013319194301330856 XMONUMENT BUTTE FED 12-27

1 soo 750 a 1.500 FeetWEST MONUMENT 10-28

i

Page 23: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

WORKSHEETAPPLICATION FOR PERMIT TO DRILL

APD RECEIVED: 5/19/2009 API NO. ASSIGNED: 43013500330000

WELL NAME: Federal 10-21-8-16

OPERATOR: NEWFIELD PRODUCTION COMPANY (N2695) PHONE NUMBER: 435 646-4825

CONTACT: Mandie Crozier

PROPOSED LOCATION: NWSE 21 080S 160E Permit Tech Review:

SURFACE: 2090 FSL 1941 FEL Engineering Review:

BOTTOM: 2090 FSL 1941 FEL Geology Review:

COUNTY: DUCHESNE

LATITUDE: 40.10196 LONGITUDE: -110.12101

UTM SURF EASTINGS: 574921.00 NORTHINGS: 4439234.00

FIELD NAME: MONUMENT BUTTE

LEASE TYPE: 1 - Federal

LEASE NUMBER: UTU-69060 PROPOSED PRODUCING FORMATION(S): GREEN RIVER

SURFACE OWNER: 1 - Federal COALBED METHANE: NO

RECEIVED AND/OR REVIEWED: LOCATION AND SITING:

PLAT R649-2-3.

Bond: FEDERAL - WYB000493 Unit:

Potash R649-3-2. General

Oil Shale 190-5

Oil Shale 190-3 R649-3-3. Exception

Oil Shale 190-13 Drilling Unit

Water Permit: 43-7478 Board Cause No: R649-3-2

RDCC Review: Effective Date:

Fee Surface Agreement Siting:

Intent to Commingle R649-3-11. Directional Drill

Commingling Approved

Comments: Presite Completed

Stipulations: 4 - Federal Approval - dmason 23 - Spacing - dmason

WORKSHEETAPPLICATION FOR PERMIT TO DRILL

I

I

APD RECEIVED: 5/19/2009 API NO. ASSIGNED: 43013500330000

WELL NAME: Federal 10-21-8-16

OPERATOR: NEWFIELD PRODUCTION COMPANY (N2695) PHONE NUMBER: 435 646-4825

CONTACT: Mandie Crozier

PROPOSED LOCATION: NWSE 21 0805 160E Permit Tech Review:

SURFACE: 2090 FSL 1941 FEL Engineering Review:

BOTTOM: 2090 FSL 1941 FEL Geology Review:

COUNTY: DUCHESNE

LATITUDE: 40.10196 LONGITUDE: -110.12101

UTM SURF EASTINGS: 574921.00 NORTHINGS: 4439234.00

FIELD NAME: MONUMENT BUTTE

LEASE TYPE: 1 - Federal

LEASE NUMBER: UTU-69060 PROPOSED PRODUCING FORMATION(S): GREEN RIVER

SURFACE OWNER: 1 - Federal COALBED METHANE: NO

I

RECEIVED AND/OR REVIEWED: LOCATION AND SITING:

PLAT R649-2-3.

Bond: FEDERAL - WYBOOO493 Unit:

Potash R649-3-2. General

Oil Shale 190-5

Oil Shale 190-3 R649-3-3. Exception

Oil Shale 190-13 Drilling Unit

Water Permit: 43-7478 Board Cause No: R649-3-2

RDCC Review: Effective Date:

Fee Surface Agreement Siting:

Intent to Commingle R649-3-11. Directional Drill

Commingling Approved

I

Comments: Presite Completed

Stipulations: 4 - Federal Approval - dmason23 - Spacing -

Page 24: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Permit To Drill

******************Well Name:  Federal 10-21-8-16

API Well Number:  43013500330000

Lease Number:  UTU-69060

Surface Owner:   FEDERAL 

Approval Date:  6/9/2009

 

Issued to:NEWFIELD PRODUCTION COMPANY , Rt 3 Box 3630 , Myton, UT 84052

Authority:Pursuant to Utah Code Ann. §40-6-1 et seq., and Utah Administrative Code R649-3-1 et seq., theUtah Division of Oil, Gas and Mining issues conditions of approval, and permit to drill the listedwell. This permit is issued in accordance with the requirements of R649-3-2. The expected producingformation or pool is the GREEN RIVER Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than one pool will requireapproval in accordance with R649-3-22.

Duration:This approval shall expire one year from the above date unless substantial and continuous operationis underway, or a request for extension is made prior to the expiration date

General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and Gas ConservationGeneral Rules, and the applicable terms and provisions of the approved Application for permit to drill.

Conditions of Approval:State approval of this well does not supercede the required federal approval, which must be obtainedprior to drilling. 

This proposed well is located in an area for which drilling units (well spacing patterns) have not beenestablished through an order of the Board of Oil, Gas and Mining (the “Board”). In order to avoid thepossibility of waste or injury to correlative rights, the operator is requested, once the well has beendrilled, completed, and has produced, to analyze geological and engineering data generatedtherefrom, as well as any similar data from surrounding areas if available. As soon as is practicableafter completion of its analysis, and if the analysis suggests an area larger than the quarter-quartersection upon which the well is located is being drained, the operator is requested to seek anappropriate order from the Board establishing drilling and spacing units in conformance with suchanalysis by filing a Request for Agency Action with the Board. 

Notification Requirements:

API Well No: 43013500330000API Well No: 43013500330000

State of UtahDEPARTMENT OF NATURAL RESOURCES

MICHAEL R. STYLER

JON M. HUNTSMAN, JR.Excutiw Drotor

sowror Division of Oil, Gas and MiningGARY R. HERRERT JOHN R. BAZALieuterant Gowrver D sion Director

Permit To Drillkkkkkkkkkkkkkkkkkk

Well Name: Federal 10-21-8-16API Well Number: 43013500330000

Lease Number: UTU-69060Surface Owner: FEDERALApproval Date: 6/9/2009

Issued to:NEWFIELD PRODUCTION COMPANY , Rt 3 Box 3630 , Myton, UT 84052

Authority:Pursuant to Utah Code Ann. §40-6-1et seq., and Utah Administrative Code R649-3-1 et seq., theUtah Division of Oil, Gas and Mining issues conditions of approval, and permit to drill the listedwell. This permit is issued in accordance with the requirements of R649-3-2. The expected producingformation or pool is the GREEN RIVER Formation(s), completion into any other zones will requirefiling a Sundry Notice (Form 9). Completion and commingling of more than one pool will requireapproval in accordance with R649-3-22.

Duration:This approval shall expire one year from the above date unless substantial and continuous operationis underway, or a request for extension is made prior to the expiration date

General:Compliance with the requirements of Utah Admin. R. 649-1 et seq., the Oil and Gas ConservationGeneral Rules, and the applicable terms and provisions of the approved Application for permit to drill.

Conditions of Approval:State approval of this well does not supercede the required federal approval, which must be obtainedprior to drilling.

This proposed well is located in an area for which drilling units (well spacing patterns) have not beenestablished through an order of the Board of Oil, Gas and Mining (the "Board"). In order to avoid thepossibility of waste or injury to correlative rights, the operator is requested, once the well has beendrilled, completed, and has produced, to analyze geological and engineering data generatedtherefrom, as well as any similar data from surrounding areas if available. As soon as is practicableafter completion of its analysis, and if the analysis suggests an area larger than the quarter-quartersection upon which the well is located is being drained, the operator is requested to seek anappropriate order from the Board establishing drilling and spacing units in conformance with suchanalysis by filing a Request for Agency Action with the

Page 25: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Notification Requirements:Notify the Division with 24 hours of spudding the well.   • Contact Carol Daniels at (801) 538-5284.

Notify the Division prior to commencing operations to plug and abandon the well.   • Contact Dustin Doucet at (801) 538-5281 office (801) 733-0983 home

Reporting Requirements:All required reports, forms and submittals will be promptly filed with the Division, including but notlimited to the Entity Action Form (Form 6), Report of Water Encountered During Drilling (Form 7),Weekly Progress Reports for drilling and completion operations, and Sundry Notices and Reports onWells requesting approval of change of plans or other operational actions.

 

 Approved By:

For Gil HuntAssociate Director, Oil & Gas 

API Well No: 43013500330000API Well No: 43013500330000

Notification Requirements:Notify the Division with 24 hours of spudding the well.

• Contact Carol Daniels at (801) 538-5284.

Notify the Division prior to commencing operations to plug and abandon the well.• Contact Dustin Doucet at (801) 538-5281 office (801) 733-0983 home

Reporting Requirements:All required reports, forms and submittals will be promptly filed with the Division, including but notlimited to the Entity Action Form (Form 6), Report of Water Encountered During Drilling (Form 7),Weekly Progress Reports for drilling and completion operations, and Sundry Notices and Reports onWells requesting approval of change of plans or other operational actions.

Approved By:

For Gil HuntAssociate Director, Oil &

Page 26: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

API Well No: 43013500330000

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS, AND MINING

FORM 9

5.LEASE DESIGNATION AND SERIAL NUMBER: UTU-69060

SUNDRY NOTICES AND REPORTS ON WELLSDo not use this form for proposals to drill new wells, significantly deepen existing wells below currentbottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TODRILL form for such proposals.

6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

7.UNIT or CA AGREEMENT NAME: GMBU (GRRV)

1. TYPE OF WELL Oil Well

8. WELL NAME and NUMBER: Federal 10-21-8-16

2. NAME OF OPERATOR: NEWFIELD PRODUCTION COMPANY

9. API NUMBER: 43013500330000

3. ADDRESS OF OPERATOR: Rt 3 Box 3630 , Myton, UT, 84052

9. FIELD and POOL or WILDCAT: MONUMENT BUTTE

4. LOCATION OF WELL FOOTAGES AT SURFACE: 2090 FSL 1941 FEL QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: Qtr/Qtr: NWSE Section: 21 Township: 08.0S Range: 16.0E Meridian: S

COUNTY: DUCHESNE

STATE: UTAH

11.

CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

NOTICE OF INTENTApproximate date work will start:

6/1/2010

SUBSEQUENT REPORTDate of Work Completion:

SPUD REPORTDate of Spud:

DRILLING REPORTReport Date:

ACIDIZE ALTER CASING CASING REPAIR

CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

DEEPEN FRACTURE TREAT NEW CONSTRUCTION

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION

REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

Newfield proposes to extend the permit to drill this well for one year.

NAME (PLEASE PRINT) Mandie Crozier

TITLE Regulatory Tech

SIGNATURE N/A

DATE 6/1/2010

PHONE NUMBER:435 646-4825 Ext

PHONE NUMBER435 646-4825

June 01, 2010

June 03, 2010

iPI Well No: 43013500330000

FORM 9

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS, AND MINING EAS6E90D6EOSIGNATIONAND SERIAL NUMBER:

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen e×isting wells below currentbottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO 7.UNIT or CA AGREEMENT NAME:

DRILL form for such proposals. GMBU (GRRV)

1. TYPE OF WELL 8. WELL NAME and NUMBER:Oil Well Federal 10-21-8-16

2. NAME OF OPERATOR: 9. API NUMBER:NEWFIELD PRODUCTION COMPANY 43013500330000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:Rt3 Box 3630 ,Myton,UT,84052 435 646-4825 Ext MONUMENT BUTTE

4.LOCATIONOFWELL COUNTY:FOOTAGES AT SURFACE: DUCHESNE

2090 FSL 1941 FELQTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

Qtr/Qtr: NWSE Section: 21 Township: 08.05 Range: 16.0E Meridian: S UTAH

11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACIDIZE ALTER CASING CASING REPAIR

/ NOTICE OF INTENTApproximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

6/1/2010CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION

SPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR CC MPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

Newfield proposes to extend the permit to drill this well for one year.Approved by theUtah Division of

Oil, Gas and Mining

Date 2010

NAME (PLEASE PRINT) PHONE NUMBER TITLEMandie Crozier 435 646-4825 Regulatory Tech

SIGNATURE DATEN/A 6/1/2010

RECEIVED June 01,

Page 27: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

The Utah Division of Oil, Gas, and Mining

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry Notices

Request for Permit Extension Validation Well Number 43013500330000

API: 43013500330000Well Name: Federal 10-21-8-16

Location: 2090 FSL 1941 FEL QTR NWSE SEC 21 TWNP 080S RNG 160E MER SCompany Permit Issued to: NEWFIELD PRODUCTION COMPANY

Date Original Permit Issued: 6/9/2009

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies thatthe information as submitted in the previously approved application to drill, remains valid and does notrequire revision. Following is a checklist of some items related to the application, which should be verified.

If located on private land, has the ownership changed, if so, has the surface agreement beenupdated? Yes No

Have any wells been drilled in the vicinity of the proposed well which would affect the spacing orsiting requirements for this location? Yes No

Has there been any unit or other agreements put in place that could affect the permitting or operationof this proposed well? Yes No

Have there been any changes to the access route including ownership, or rightof- way, which couldaffect the proposed location? Yes No

Has the approved source of water for drilling changed? Yes No

Have there been any physical changes to the surface location or access route which will require achange in plans from what was discussed at the onsite evaluation? Yes No

Is bonding still in place, which covers this proposed well? Yes No

Signature: Mandie Crozier Date: 6/1/2010

Title: Regulatory Tech Representing: NEWFIELD PRODUCTION COMPANY

June 01, 2010

June 03, 2010

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural ResourcesElectronic Permitting System - Sundry Notices

OTI GAS MlNTNG

Request for Permit Extension Validation Well Number 43013500330000

API: 43013500330000Well Name: Federal 10-21-8-16

Location: 2090 FSL 1941 FEL QTR NWSE SEC 21 TWNP 0805 RNG 160E MER SCompany Permit Issued to: NEWFIELD PRODUCTION COMPANY

Date Original Permit Issued: 6/9/2009

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies thatthe information as submitted in the previously approved application to drill, remains valid and does notrequire revision. Following is a checklist of some items related to the application, which should be verified.

•If located on private_land, has the ownership changed, if so, has the surface agreement beenupdated? I___|I Yes I_Ð_I No

• Have any wells been drilled in the vicinity of the_proposed well which would affect the spacing orsiting requirements for this location? I:___) Yes _®_) No

• Has there been any unit or other agreements put in place that could affect the permitting or operationof this proposed well? I i Yes i i No

• Have there been any changes to the access route including ownership, or rightof- way, which couldaffect the proposed location? I___) Yes I _I No

• Has the approved source of water for drilling changed? I __I Yes i i No

• Have there been any physical changes to the surface location or access route which will require achange in plans from what was discussed at the onsite evaluation? I___I Yes I®I No

Approved by the•Is bonding still in place, which covers this proposed well? I§|I Yes i i No Utah Division of

Oil, Gas and MiningSignature: Mandie Crozier Date: 6/1/2010

Title: Regulatory Tech Representing: NEWFIELD PRODUCTION COMPANY Date: June 03, 2010

By:

RECEIVED June 01,

Page 28: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS, AND MINING

FORM 9

5.LEASE DESIGNATION AND SERIAL NUMBER: UTU-69060

SUNDRY NOTICES AND REPORTS ON WELLSDo not use this form for proposals to drill new wells, significantly deepen existing wells below currentbottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TODRILL form for such proposals.

6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

7.UNIT or CA AGREEMENT NAME: GMBU (GRRV)

1. TYPE OF WELL Oil Well

8. WELL NAME and NUMBER: FEDERAL 10-21-8-16

2. NAME OF OPERATOR: NEWFIELD PRODUCTION COMPANY

9. API NUMBER: 43013500330000

3. ADDRESS OF OPERATOR: PHONE NUMBER: Rt 3 Box 3630 , Myton, UT, 84052 435 646-4825 Ext

9. FIELD and POOL or WILDCAT: MONUMENT BUTTE

4. LOCATION OF WELL FOOTAGES AT SURFACE: 2090 FSL 1941 FEL QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: Qtr/Qtr: NWSE Section: 21 Township: 08.0S Range: 16.0E Meridian: S

COUNTY: DUCHESNE

STATE: UTAH

11.

CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

NOTICE OF INTENTApproximate date work will start:

6/9/2011

SUBSEQUENT REPORTDate of Work Completion:

SPUD REPORTDate of Spud:

DRILLING REPORTReport Date:

ACIDIZE ALTER CASING CASING REPAIR

CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

DEEPEN FRACTURE TREAT NEW CONSTRUCTION

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION

REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSION

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

Newfield proposes to extend the Application for Permit to Drill for one year.

NAME (PLEASE PRINT) PHONE NUMBER Mandie Crozier 435 646-4825

TITLE Regulatory Tech

SIGNATURE N/A

DATE 6/2/2011

06/06/2011

Jun. 02, 2011

Sundry Number: 15508 API Well Number: 43013500330000

FORM 9STATE OF UTAH

DEPARTMENT OF NATURAL RESOURCESDIVISION OF OIL, GAS, AND MINING 5.LEASE D6EOSIGNATION AND SERIAL NUMBER:

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells below currentbottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO 7.UNIT or CA AGREEMENT NAME:

DRILL form for such proposals. GMBU (GRRV)

1. TYPE OF WELL 8. WELL NAME and NUMBER:Oil Well FEDERAL 10-21-8-16

2. NAME OF OPERATOR: 9. API NUMBER:NEWFIELD PRODUCTION COMPANY 43013500330000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:Rt 3 Bo× 3630 , Myton, UT, 84052 435 646-4825 E×t MONUMENT BUTTE

4.LOCATIONOFVVELL COUNTY:FOOTAGES AT SURFACE: DUCHESNE

2090 FSL 1941 FELQTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

Qtr/Qtr: NWSE Section: 21 Township: 08.05 Range: 16.0E Meridian: S UTAH

11.CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACIDIZE ALTER CASING CASING REPAIR

/ NOTICE OF INTENTApproximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

6/9/2011CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENT REPORT DEEPEN FRACTURE TREAT NEW CONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATION

SPUD REPORTDate of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR C( MPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

Newfield proposes to extend the Application for Permit to Drill for one year.

Approved by theUtah Division of

Oil, Gas and Mining

Date: 06/06/2011

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEMandie Crozier 435 646-4825 Regulatory Tech

SIGNATURE DATEN/A 6/2/2011

Page 29: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

The Utah Division of Oil, Gas, and Mining

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry Notices

Request for Permit Extension Validation Well Number 43013500330000

API: 43013500330000Well Name: FEDERAL 10-21-8-16

Location: 2090 FSL 1941 FEL QTR NWSE SEC 21 TWNP 080S RNG 160E MER SCompany Permit Issued to: NEWFIELD PRODUCTION COMPANY

Date Original Permit Issued: 6/9/2009

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies thatthe information as submitted in the previously approved application to drill, remains valid and does notrequire revision. Following is a checklist of some items related to the application, which should be verified.

If located on private land, has the ownership changed, if so, has the surface agreement beenupdated? Yes No

Have any wells been drilled in the vicinity of the proposed well which would affect the spacing orsiting requirements for this location? Yes No

Has there been any unit or other agreements put in place that could affect the permitting or operationof this proposed well? Yes No

Have there been any changes to the access route including ownership, or rightof- way, which couldaffect the proposed location? Yes No

Has the approved source of water for drilling changed? Yes No

Have there been any physical changes to the surface location or access route which will require achange in plans from what was discussed at the onsite evaluation? Yes No

Is bonding still in place, which covers this proposed well? Yes No

Signature: Mandie Crozier Date: 6/2/2011

Title: Regulatory Tech Representing: NEWFIELD PRODUCTION COMPANY

Jun. 02, 2011

Sundry Number: 15508 API Well Number: 43013500330000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural ResourcesElectronic Permitting System - Sundry Notices

OTI GAS Rr MlNTNG

Request for Permit Extension Validation Well Number 43013500330000

API: 43013500330000Well Name: FEDERAL 10-21-8-16

Location: 2090 FSL 1941 FEL QTR NWSE SEC 21 TWNP 0805 RNG 160E MER SCompany Permit Issued to: NEWFIELD PRODUCTION COMPANY

Date Original Permit Issued: 6/9/2009

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies thatthe information as submitted in the previously approved application to drill, remains valid and does notrequire revision. Following is a checklist of some items related to the application, which should be verified.

•If located o_nprivate_land, has the ownership changed, if so, has the surface agreement beenupdated? I

_

i Yes igi No

• Have any wells been drilled in the vicinity of the_proposed well which would affect the spacing orsiting requirements for this location? :__I Yes g:I No

• Has there been any unit or other agreements put in place that could affect the permitting or operationof this proposed well? I:_:I Yes IÏiÏ:I No

• Have there been any changes to the access route including ownership, or rightof- way, which couldaffect the proposed location? I___I Yes igi No

• Has the approved source of water for drilling changed? I_

I Yes IÎiÏI No

• Have there been any physical changes to the surface location or access route which will require achange in plans from what was discussed at the onsite evaluation? __:I Yes ig:I No

• Is bonding still in place, which covers this proposed well? liiil Yes i i No

Signature: Mandie Crozier Date: 6/2/2011Title: Regulatory Tech Representing: NEWFIELD PRODUCTION COMPANY

Page 30: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

ru 000 UNITED STATES RECE FORM APPROVEDDEPARTMÉNT OF THE INTERIOR OMB NO. 1004-0135

BUREAU OF LAND MANAGEMENT Î 5. Lease Ser!ExNpiresJuly 31, 2010

SUNDRY NOTICESANDREPORTS ON WELLS UTU69060

6. If Indian Allottee or Tribe Name

SUBMIT IN TRIPLICATE - Other instructions on reverse side. 7. If Umtor CA/Agreement, Name and/or No.UTU87538X

1. Type orWell 8. WellNaneand No.FEDERAL 10-21-8-16

Oil Well O Gas Well Other2. Name of operator CoÑút MANDII-HURUAÍH .

Al>l WellNo.NEWFIELD EXPLORATION COMPANW-Mail: [email protected] 43-013-50033-00-X1

3a. Address 3b. ½oneNo.(melude area code) 10. Beidand Pool,or ExploratoryROUTE 3 BOX 3630 Ph: 435-646-4825 MONUMENT BUTTEMYTON,UT 84052

4. Locationof Well (Footage, Sec., T, k, Ai.,or Survey bescnption 11. County or Parish,and State

Sec 21 T8S R16E NWSE 2090FSL 1941FEL . DUCHIËSNE COUNTY, UT

12. CHECK APPROPRIATE BOX(ES) TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

Notice of IntentAcidize O Deepen 0 Production (Start/Resume) Water Shut-Off

O Alter casing 0 Fracture Treat 0 Reclamation 0 Well Integrity

0 Subsequent Report Casing Repair g New Construction 0 Recomplete Other

O Final Abandonment Notice Change Plans O Plug and Abandon g TemporarilyAbandon PDange to Original

O Convert to Injection Plug Back O Water Disposal

f3 besenbe Proposedor completedop rat on (clearly state all:pertment detais,meludmg estimated starting dateof any proposed work and approximate durationthereot.If the proposal is to deepen directionally or recomplete horizontally, give subsurface locations and measured and true vertical depths of alj pertinent markers and zones.Attach the Bond under which the work will be performed or provide the Bond No. on file with BLM/BIA. Required subsequent reports shall be filed within 30 daysfollowing completion of the involved operations. If the operation results in amultiple completion or recompletion in a new interval a Form 3160-4 shall be filed oncetesting has been completed. Final Abandonment Notices shall be filed only after all requirements, including reclamation, have been completed, and the operator hasdNe ed

qu

sSt

t

deyn

te ppl n for Permit to Drillthis well for two more years.

CONDITIONSOFAPPROVALATTACHEDREC

14. I herebycertify that the foregoingisrae and correct.Electronic Submission #123016 verifit i by the BLM Well Information System

For NEWFIELD EXPLORATIOA COMPANY, sent to the VernalCommitted to AFMSS for processing by ROE N R. HANSEN on 11/14/2011 (12RRHO641SE)

Name(Printed/Typed) MANDIE H CROZIER Title REGULATORYANALYST

Signature (Electronic Submission) Date 11/10/2011

THISSPACE FOR FEDERAL OR STATE OFFICE USE

Approved By Title NO"at8WRConditions of appr if y attached. Approval of this notice does not warrant orcertify that the a t ol egal or equitable title to those rights in the subject lease ass•nu A I I I C Iwhich would entiti the applicant to coriduct operations thereon Office VGrtlmL. I I I- I i

Title 18 U.S.C. Section .1001and Title 43 U.S.C. Section 1212, make it a crime for any person knowingly and willfully to make to any department or agency of the UnitedStates an fals , fictitious är fraudulent statements or representations as to any matter within its jurisdiction.

** BLM REVISED ** BLM REVISED ** BLM REVISED ** BLM REVISED** BLM REVISED

Page 31: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

CONDITIONS OF APPROVAL

Newfield Exploration Company

Notice of IntentAPD Extension

Lease: UTU-69060Well: Federal 10-21-8-16Location: NWSE Sec 21-T8S-R16E

An extension for the referenced APD is granted with the following conditions:

1. The extension and APD shall expire on 12/15/2013.

2. No other extension shall be granted.

If you have any other questions concerning this matter, please contact Robin L Hansen of thisoffice at (435)

Page 32: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

RECEIVED: May. 30, 2012

 

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS, AND MINING

FORM 9 

5.LEASE DESIGNATION AND SERIAL NUMBER: UTU-69060

SUNDRY NOTICES AND REPORTS ON WELLS

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATIONFOR PERMIT TO DRILL form for such proposals.

6. IF INDIAN, ALLOTTEE OR TRIBE NAME: 

7.UNIT or CA AGREEMENT NAME: GMBU (GRRV)

1. TYPE OF WELL  Oil Well

8. WELL NAME and NUMBER: FEDERAL 10-21-8-16

2. NAME OF OPERATOR: NEWFIELD PRODUCTION COMPANY

9. API NUMBER: 43013500330000

3. ADDRESS OF OPERATOR: PHONE NUMBER:  Rt 3 Box 3630 , Myton, UT, 84052 435 646-4825  Ext

9. FIELD and POOL or WILDCAT: MONUMENT BUTTE

4. LOCATION OF WELL  FOOTAGES AT SURFACE:     2090 FSL 1941 FEL   QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN:     Qtr/Qtr: NWSE Section: 21 Township: 08.0S Range: 16.0E Meridian: S

COUNTY: DUCHESNE

STATE: UTAH

11.

CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

 

    NOTICE OF INTENTApproximate date work will start:

6 /9 /2012

    SUBSEQUENT REPORTDate of Work Completion:

 

    SPUD REPORTDate of Spud:

 

    DRILLING REPORTReport Date:

 

    ACIDIZE      ALTER CASING      CASING REPAIR 

    CHANGE TO PREVIOUS PLANS      CHANGE TUBING      CHANGE WELL NAME 

    CHANGE WELL STATUS      COMMINGLE PRODUCING FORMATIONS      CONVERT WELL TYPE  

    DEEPEN      FRACTURE TREAT      NEW CONSTRUCTION 

    OPERATOR CHANGE      PLUG AND ABANDON      PLUG BACK 

    PRODUCTION START OR RESUME      RECLAMATION OF WELL SITE      RECOMPLETE DIFFERENT FORMATION 

    REPERFORATE CURRENT FORMATION      SIDETRACK TO REPAIR WELL      TEMPORARY ABANDON 

    TUBING REPAIR      VENT OR FLARE       WATER DISPOSAL 

    WATER SHUTOFF      SI TA STATUS EXTENSION      APD EXTENSION 

    WILDCAT WELL DETERMINATION      OTHER  OTHER: 

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

Newfield proposes to extend the Application for Permit to Drill this wellfor one year.

NAME (PLEASE PRINT) PHONE NUMBER  Mandie Crozier 435 646-4825

TITLE Regulatory Tech

SIGNATURE N/A

DATE 5 /30 /2012

June 04, 2012

Sundry Number: 26225 API Well Number: 43013500330000Sundry Number: 26225 API Well Number: 43013500330000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTU-69060

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. GMBU (GRRV)

1. TYPE OF WELL 8. WELL NAME and NUMBER:Oil Well FEDERAL 10-21-8-16

2. NAME OF OPERATOR: 9. API NUMBER:NEWFIELD PRODUCTION COMPANY 43013500330000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:Rt 3 Box 3630 , Myton, UT, 84052 435 646-4825 Ext MONUMENT BUTTE

4. LOCATION OF WELL COUNTY:FOOTAGES AT SURFACE: DUCHESNE

2090 FSL 1941 FELQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWSE Section: 21 Township: 08.0S Range: 16.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

6/9/2012CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

Newfield proposes to extend the Application for Permit to Drill this well Approved by thefor one year. Utah Division of

OFI, Gas and Mining

Date: June 04, 2012

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEMandie Crozier 435 646-4825 Regulatory Tech

SIGNATURE DATEN/A 5/30/2012

RECEIVED: May. 30,

Page 33: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

RECEIVED: May. 30, 2012

 

The Utah Division of Oil, Gas, and Mining

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry Notices

Request for Permit Extension Validation Well Number 43013500330000 

API:  43013500330000Well Name:  FEDERAL 10-21-8-16

Location:  2090 FSL 1941 FEL QTR NWSE SEC 21 TWNP 080S RNG 160E MER SCompany Permit Issued to:  NEWFIELD PRODUCTION COMPANY

Date Original Permit Issued:  6 /9 /2009

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

If located on private land, has the ownership changed, if so, has the surface agreement been updated?   Yes     No

Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location?    Yes     No

Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well?    Yes     No

Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location?    Yes     No

Has the approved source of water for drilling changed?    Yes     No

Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation?    Yes     No

Is bonding still in place, which covers this proposed well?    Yes     No

       Signature:  Mandie Crozier Date: 5 /30 /2012

Title:  Regulatory Tech Representing: NEWFIELD PRODUCTION COMPANY

Sundry Number: 26225 API Well Number: 43013500330000Sundry Number: 26225 API Well Number: 43013500330000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural ResourcesElectronic Permitting System - Sundry Notices

OTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43013500330000

API: 43013500330000Well Name: FEDERAL 10-21-8-16

Location: 2090 FSL 1941 FEL QTR NWSE SEC 21 TWNP 080S RNG 160E MER SCompany Permit Issued to: NEWFIELDPRODUCTION COMPANY

Date Original Permit Issued: 6/9/2009

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Mandie Crozier Date: 5/30/2012Title: Regulatory Tech Representing: NEWFIELDPRODUCTION COMPANY

RECEIVED: May. 30,

Page 34: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

RECEIVED: Jun. 04, 2013

 

STATE OF UTAHDEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS, AND MINING

FORM 9 

5.LEASE DESIGNATION AND SERIAL NUMBER: UTU-69060

SUNDRY NOTICES AND REPORTS ON WELLS

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATIONFOR PERMIT TO DRILL form for such proposals.

6. IF INDIAN, ALLOTTEE OR TRIBE NAME: 

7.UNIT or CA AGREEMENT NAME: GMBU (GRRV)

1. TYPE OF WELL  Oil Well

8. WELL NAME and NUMBER: FEDERAL 10-21-8-16

2. NAME OF OPERATOR: NEWFIELD PRODUCTION COMPANY

9. API NUMBER: 43013500330000

3. ADDRESS OF OPERATOR: PHONE NUMBER:  Rt 3 Box 3630 , Myton, UT, 84052 435 646-4825  Ext

9. FIELD and POOL or WILDCAT: MONUMENT BUTTE

4. LOCATION OF WELL  FOOTAGES AT SURFACE:     2090 FSL 1941 FEL   QTR/QTR, SECTION, TOWNSHIP, RANGE, MERIDIAN:     Qtr/Qtr: NWSE Section: 21 Township: 08.0S Range: 16.0E Meridian: S

COUNTY: DUCHESNE

STATE: UTAH

11.

CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

 

    NOTICE OF INTENTApproximate date work will start:

6 /9 /2013

    SUBSEQUENT REPORTDate of Work Completion:

 

    SPUD REPORTDate of Spud:

 

    DRILLING REPORTReport Date:

 

    ACIDIZE      ALTER CASING      CASING REPAIR 

    CHANGE TO PREVIOUS PLANS      CHANGE TUBING      CHANGE WELL NAME 

    CHANGE WELL STATUS      COMMINGLE PRODUCING FORMATIONS      CONVERT WELL TYPE  

    DEEPEN      FRACTURE TREAT      NEW CONSTRUCTION 

    OPERATOR CHANGE      PLUG AND ABANDON      PLUG BACK 

    PRODUCTION START OR RESUME      RECLAMATION OF WELL SITE      RECOMPLETE DIFFERENT FORMATION 

    REPERFORATE CURRENT FORMATION      SIDETRACK TO REPAIR WELL      TEMPORARY ABANDON 

    TUBING REPAIR      VENT OR FLARE       WATER DISPOSAL 

    WATER SHUTOFF      SI TA STATUS EXTENSION      APD EXTENSION 

    WILDCAT WELL DETERMINATION      OTHER  OTHER: 

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

Newfield proposes to extend the Application for Permit to Drill this wellfor on year.

NAME (PLEASE PRINT) PHONE NUMBER  Mandie Crozier 435 646-4825

TITLE Regulatory Tech

SIGNATURE N/A

DATE 6 /4 /2013

June 05, 2013

Sundry Number: 38549 API Well Number: 43013500330000Sundry Number: 38549 API Well Number: 43013500330000

FORM 9STATE OF UTAH

DEPARTMENTOF NATURALRESOURCES5.LEASE DESIGNATION AND SERIAL NUMBER:DIVISION OF OIL, GAS, AND MINING UTU-69060

SUNDRY NOTICES AND REPORTS ON WELLS 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

Do not use this form for proposals to drill new wells, significantly deepen existing wells belowcurrent bottom-hole depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION 7.UNITor CA AGREEMENT NAME:

FOR PERMIT TO DRILL form for such proposals. GMBU (GRRV)

1. TYPE OF WELL 8. WELL NAME and NUMBER:Oil Well FEDERAL 10-21-8-16

2. NAME OF OPERATOR: 9. API NUMBER:NEWFIELD PRODUCTION COMPANY 43013500330000

3. ADDRESS OF OPERATOR: PHONE NUMBER: 9. FIELD and POOL or WILDCAT:Rt 3 Box 3630 , Myton, UT, 84052 435 646-4825 Ext MONUMENT BUTTE

4. LOCATION OF WELL COUNTY:FOOTAGES AT SURFACE: DUCHESNE

2090 FSL 1941 FELQTRIQTR, SECTION, TOWNSHIP, RANGE, MERIDIAN: STATE:

QtrlQtr: NWSE Section: 21 Township: 08.0S Range: 16.0E Meridian: S UTAH

CHECK APPROPRIATE BOXES TO INDICATENATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

ACI DIZE ALTER CASING CASING REPAIRNOTICE OF INTENT

Approximate date work will start: CHANGE TO PREVIOUS PLANS CHANGE TUBING CHANGE WELL NAME

6/9/2013CHANGE WELL STATUS COMMINGLE PRODUCING FORMATIONS CONVERT WELL TYPE

SUBSEQUENTREPORT DEEPEN FRACTURETREAT NEWCONSTRUCTIONDate of Work Completion:

OPERATOR CHANGE PLUG AND ABANDON PLUG BACK

PRODUCTION START OR RESUME RECLAMATION OF WELL SITE RECOMPLETE DIFFERENT FORMATIONSPUD REPORT

Date of Spud: REPERFORATE CURRENT FORMATION SIDETRACK TO REPAIR WELL TEMPORARY ABANDON

TUBING REPAIR VENT OR FLARE WATER DISPOSAL

DRILLING REPORT WATER SHUTOFF SI TA STATUS EXTENSION APD EXTENSIONReport Date:

WILDCAT WELL DETERMINATION OTHER OTHER:

12. DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

Newfield proposes to extend the Application for Permit to Drill this well Approved by thefor on year. Utah Division of

OFI, Gas and Mining

Date: June 05, 2013

By:

NAME (PLEASE PRINT) PHONE NUMBER TITLEMandie Crozier 435 646-4825 Regulatory Tech

SIGNATURE DATEN/A 6/4/2013

RECEIVED: Jun. 04,

Page 35: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

RECEIVED: Jun. 04, 2013

 

The Utah Division of Oil, Gas, and Mining

- State of Utah- Department of Natural Resources

Electronic Permitting System - Sundry Notices

Request for Permit Extension Validation Well Number 43013500330000 

API:  43013500330000Well Name:  FEDERAL 10-21-8-16

Location:  2090 FSL 1941 FEL QTR NWSE SEC 21 TWNP 080S RNG 160E MER SCompany Permit Issued to:  NEWFIELD PRODUCTION COMPANY

Date Original Permit Issued:  6 /9 /2009

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

If located on private land, has the ownership changed, if so, has the surface agreement been updated?   Yes     No

Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location?    Yes     No

Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well?    Yes     No

Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location?    Yes     No

Has the approved source of water for drilling changed?    Yes     No

Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation?    Yes     No

Is bonding still in place, which covers this proposed well?    Yes     No

       Signature:  Mandie Crozier Date: 6 /4 /2013

Title:  Regulatory Tech Representing: NEWFIELD PRODUCTION COMPANY

Sundry Number: 38549 API Well Number: 43013500330000Sundry Number: 38549 API Well Number: 43013500330000

UTAH

DNR The Utah Division of Oil, Gas, and Mining'

- State of Utah- Department of Natural ResourcesElectronic Permitting System - Sundry Notices

OTI. EMI Pr N1NTrie

Request for Permit Extension Validation Well Number 43013500330000

API: 43013500330000Well Name: FEDERAL 10-21-8-16

Location: 2090 FSL 1941 FEL QTR NWSE SEC 21 TWNP 080S RNG 160E MER SCompany Permit Issued to: NEWFIELDPRODUCTION COMPANY

Date Original Permit Issued: 6/9/2009

The undersigned as owner with legal rights to drill on the property as permitted above, hereby verifies that theinformation as submitted in the previously approved application to drill, remains valid and does not require revision.Following is a checklist of some items related to the application, which should be verified.

* If located on private land, has the ownership changed, if so, has the surface agreement been updated? OYes No

• Have any wells been drilled in the vicinity of the proposed well which would affect the spacing or sitingrequirements for this location? O Yes No

• Has there been any unit or other agreements put in place that could affect the permitting or operation of thisproposed well? (_) Yes No

• Have there been any changes to the access route including ownership, or rightof- way, which could affect theproposed location? O Yes i No

· Has the approved source of water for drilling changed? O Yes No

• Have there been any physical changes to the surface location or access route which will require a change inplans from what was discussed at the onsite evaluation? Yes No

' Is bonding still in place, which covers this proposed well? Yes No

Signature: Mandie Crozier Date: 6/4/2013Title: Regulatory Tech Representing: NEWFIELDPRODUCTION COMPANY

RECEIVED: Jun. 04,

Page 36: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

State of UtahDEPARTMENT OF NATURAL RESOURCES

tensMICHAEL R. STYLER

GARY R. HERBERT Executive Director

covernor Division of Oil, Gas and MiningGREGORY S. BELL JOHN R. BAZALieutenant Governor Division Director

August 28, 2013

Mandie CrozierNewfield Production CompanyRoute #3 Box 3630Myton, UT 84052

Re: APDs Rescinded for Newfield Production Company,Duchesne County

Dear Ms. Crozier:

Enclosed find the list of APDs that you have asked to be rescinded. No drillingactivity at these locations has been reported to the division. Therefore,approval to drill these wells is hereby rescinded, effective August 27, 2013.

A new APD must be filed with this office for approval prior to thecommencement of any future work on the subject location.

If any previously unreported operations have been performed on this welllocation, it is imperative that you notify the Division immediately.

Sincerely,

l iana MasonEnvironmental Scientist

cc: Well FileBureau of Land Management, VernalSITLA, Ed Bonner

UTAH

DNR

1594 West North Temple, Suite 1210, PO Box 145801, Salt Lake City, UT 84114 -5801

telephone (801) 538-5340 • facsimile (801) 359-3940 •TTY (801) 538-7458 • www.ogm.utah.govOIL, GAS &

Page 37: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

8/28/13 State of Utah Mail - APD's to Rescind

APD's to Rescind

Mandie Crozier <[email protected]> Tue, Aug 27, 2013 at 4:18 PMTo: "[email protected]' <[email protected]>

Newfield would like to have the followingApproved APD's Rescinded. (See attached list).Most of these APD's were permitted and approved in 2010 or earlier. We would like toemphasize thatthis is not an on-going issue and thatwe have drilled or plan to drill95% of theAPD's we've applied for in recent years. These were some areas and play typesthatwe wereassessing that we had to permit in advance due to long permit lag time -- thiscaused us to"over-permit" these areas/plays so that we would have options to drill if successful.

Mandie CrozierRegulatory Specialist.Office: 435-646-4825Mobile: 435-401-8335

NEWFIELD

APD's to Rescind_001.pdf194K

https://mail.google.com/maillul0/?ui=2&ik=8d7a8b69b3&Mew-pt&search=inbox&msg=140c1db73e13a3ed

Page 38: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Cas

eN

umbe

rW

ell N

ame

Num

Leas

eTY

PEC

omm

ent

UTU

8753

8XFE

DER

AL

10-2

1-8-

16U

TU69

060

4043

0135

0033

UTU

8753

8XH

AW

KEY

EFE

DER

AL

10-2

2-8-

16U

TU73

088

4043

0135

0094

UTU

8753

8XFE

DER

AL

11-2

1-8-

16U

TU69

061

4043

0135

0034

UTU

8753

8XFE

DER

AL

11-2

2-8-

16U

TU77

339

4043

0135

0085

UTU

B75

38X

HA

WK

EYE F

EDER

AL

11-2

7-8-

16U

TU73

088

4043

0135

0057

UTU

8753

8XFE

DER

AL

11-3

5-8-

15U

TU67

168

4043

0133

4252

i

UTU

8753

8XST

ATE

11-3

6-8-

15ST

ATE

4043

0133

4225

UTU

8753

8XFE

DER

AL

1-21

-8-1

6U

TU69

060

4043

0135

0025

UTU

8753

8XFE

DER

AL

12-2

2-8-

16U

TSLO

6591

440

4301

3500

86

UTU

8753

8XFE

DER

AL

12-2

5-8-

15U

TU67

168

4043

0135

0048

UTU

8753

8XH

AW

KEY

EFE

DER

AL

12-2

7-8-

16U

TU73

088

4043

0135

0056

UTU

8753

8XFE

DER

AL

1-25

-8-1

5U

TU67

168

4043

0135

0027

UTU

B75

38X

HA

WK

EYE F

EDER

AL

1-27

-8-1

6U

TU73

088

4043

0135

0040

UTU

8753

8XFE

DER

AL

1-29

-8-1

6U

TU69

061

4043

0135

0144

iU

TU87

538X

FED

ERA

L1-

30-8

-16

UTU

8100

040

4301

3341

92

UTU

8753

8XFE

DER

AL

13-1

9-8-

16U

TU73

089

40

Page 39: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

UTU

8753

8XFE

DER

AL

14-K

i-8-1

6U

TU73

089

4043

0133

4169

UTU

8753

8XFE

DER

AL

14-2

1-B

-16

UTU

6906

140

4301

3500

29

UTU

8753

BX

FED

EIL4

L14

-22-

8-16

UTU

7733

940

4301

3501

00

UTU

8753

8XTR

AV

ISFE

DER

AL

14-2

7-8-

16U

TU62

848

4043

0135

0055

UTU

8753

8XFE

DER

AL

15-1

9-8-

16U

TU73

089

4043

0133

4168

UTU

8753

8XFE

DER

AL

15-2

1-8-

16U

TU69

060

4043

0135

0028

UTU

8753

8XFE

DER

AL

16-K

i-8-1

6U

TU73

089

4043

0133

4167

UTU

8753

8XFE

NC

ELIN

EFE

DER

AL

1A-2

2-8-

16U

TU74

868

4043

0135

0090

UTU

8753

8XFE

DEI

LAL

2-21

-8-1

6U

TU69

060

4043

0135

0030

UTU

8753

8XFE

NC

ELIN

EFED

EILA

L2-

22-8

-16

UTU

7486

840

4301

3508

91

UTU

8753

8XH

AW

KEY

EFED

ERA

L2-

27-8

-16

UTU

7308

840

4301

3500

41

UTU

8753

8XFE

DEF

U\L

2-29

-8-1

6U

TU69

061

4043

0133

4178

WES

TPO

INT

UTU

8753

8X2-

31-8

-16

UTU

7438

940

4301

3342

00FE

DEF

LAL

UTU

8753

8XFE

DEI

LAL

3-22

-8-1

6U

TU76

561

4043

0135

0082

UTU

8753

8XFE

DEI

LAL

3-29

-8-1

6U

TU69

060

4043

0133

4177

UTU

8753

8XFE

DER

AL

3-30

-8-1

6U

TUB

1000

4043

0133

4190

UTU

8753

8XFE

DEI

LAL

4-22

-8-1

6U

TU76

561

40

Page 40: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

UTU

8753

8XFE

NC

ELIN

EFED

ERA

L4-

23-8

-16

UTU

7486

840

4301

3501

30

UTU

8753

8XFE

DEF

U\L

4-27

-8-1

6U

TU77

339

4043

0135

0062

UTU

8753

8XFE

DEF

LAL

4-29

-8-1

6U

TU69

060

4043

0133

4176

UTU

8753

8XFE

DER

AL

5-22

-8-1

6U

TU76

561

4043

0135

0083

UTU

8753

8XFE

NC

ELIN

EFED

ERA

L5-

23-8

-16

UTU

7486

840

4301

3501

33

UTU

B75

38X

HA

VV

KEY

EFED

ERA

L5-

27-8

-16

UTU

7308

840

4301

3500

63

IU

TU87

538X

FED

EFL4

L5-

30-8

-16

UTU

S100

040

4301

3341

89

VV

ESTP

OIN

TU

TU87

538X

5-31

-8-1

6U

TU74

389

4043

0133

4197

FED

ERA

L

UTU

8753

8XFE

DEF

LAL

6.-2

1-8-

16U

TU69

060

4043

0135

0031

UTU

8753

8XFE

DER

AL

6-22

-8-1

6U

TU76

561

4043

0135

0084

UTU

8753

8XH

AW

KEY

EFE

DER

AL

6-27

-8-1

6U

TU73

088

4043

0135

0064

UTU

8753

8XFE

DER

AL

6-30

-8-1

6U

TU81

000

4043

0133

4188

VV

ESTP

OIN

TU

TUB

7538

X6:

-31-

8-16

UTU

7438

940

4301

3341

96FE

DER

AL

UTU

8753

8XFE

DER

AL

6-35

-8-1

5U

TU67

168

4043

0133

4247

UTU

8753

8XFE

NC

ELIN

EFED

ERA

L7-

22-8

-16

UTU

7486

840

4301

3500

91

UTU

8753

8XH

AW

KEY

EFE

DER

AL

7-27

-8-1

6U

TU73

088

4043

0135

0058

UTU

8753

8XFE

DER

AL

7-35

-8-1

5U

TU67

168

40

Page 41: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

UTU

8753

8XFE

DER

AL

8-21

-8-1

6U

TU69

060

4043

0135

0032

UTU

8753

8XFE

NC

ELIN

EFED

EIL4

L8-

22-8

-16

UTU

7486

840

4301

3500

92

IU

TU87

S38X

FED

EFU

kL8-

35-8

-15

UTU

6716

840

4301

3342

49

UTU

8753

8XFE

DEP

AL

9-20

-8-1

6U

TU77

339

4043

0135

0089

UTU

8753

8XH

AW

KEY

EFE

DER

AL

9-22

-8-1

6U

TU73

088

4043

0135

0093

UTU

8753

8XFE

DER

AL

9-35

-8-1

5U

TU67

168

4043

0133

4250

UTU

8753

8XG

.MB

UG

i-32-

8-16

STA

TE20

4301

3508

35

UTU

8753

8XG

IMB

UH

-32-

8-16

STA

DE

2043

0135

0836

UTU

8753

8XG

MB

UL-

32-8

-16

STA

3T20

4301

3508

37

UTU

8753

8XG

MB

UQ

-32-

8-16

STA

TE20

4301

3508

38

UTU

8753

8XG

MB

UR

-32-

B-1

6ST

ATE

2043

0135

0839

I

Page 42: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Form3160-3FORM APPROVED(August2007)OMBNo.1004-0137

• ExpiresJuly31,2010UNITED STATESDEPARTMENTOF THE INTERIOR 5. LeaseSerialNo.BUREAUOF LAND MANAGEMENT UTU-69060

APPUCATION FOR PERMIT TO DRILL OR REENTER 6. IfInd ,Allotee orTribeName

la. Typeof work: DRILL O REENTER 2 ÏfUnitor CAAgreement,NameandNo.

8. Lease Nameand WellNo.lb. TypeofWell: 0 I Well GasWell Other SingleZone MultipleZone Federal 10-21-8-162. Nameof0perator Newfield Production Company 9. API WellNo.3a. Address Route #3 Box 3630, Myton UT 84052 3b. PhoneNo.(include area code) 10 FiefdantfPool,orExploratory(435) 646-3721

Monument Butte4. Locationof Well(Reportlocationclearly and in acœrdance with anyMaterequirements.*) 11 Seo.,T.R. M. or Blk.andSurveyorAreaAt surface NWISE 2090' FSL 1941' FELSec. 21, T8S R16EAt proposedprod.zone

14. Distancein milesanddirectionfrom nearesttownorpostoffice Ïi Countyor Parish 13.StateApproximately9.4 miles southwest ofMyton, UT Duchesne UT15. Distancefromproposed*16.No.of acresin lease 17. SpacingUnitdedicatedto thiswelllocationtonearest

propertyor leaseline,it. Approx. 699' f/lse, NA' flunit1130.40(Alsotonearestdrig.unit line,ifany) 40 Acres

18.Distancefrompo osedlocation* 19.ProposedDepth 20. BLM/BIABondNo.on fileapppnlotoro this

eng, ompleted, Approx. 2005' 6,690' WYBOOO49321. Elevations(ShowwhetherDF,KDB,RT,4 etc.) 22. Appr imatedateworkwillstart* 23. Estimatedduration5450' GL

(7) days from SPUD to rig release24. Attachments

Thefollowing,completedinaccordancewith therequirementsof OnshoreOilandGasOrderNo.l, mustbe attachedto thiiform:1. Wellplatcertifiedby a registeredsurveyor. 4. Bond tocover the operationsunlesscovered byan existingbondon file (see2. ADrillingPlan. Item20 above).3. A SurfaceUsePlan (if the location is on National Forest SystemLands, the 5. OperatorcertificationSUPO mustbe filedwith theappropriateForest ServiceOffice) 6. Suchothersite specificinfórmationand/orplansas mayberequiredbythe25 S Nme (ePrint ed) Da

TitleRegulatory Specialist

Approyedby (Si Name (Printed/Typed) Date

Title ASSIS eld ager officeVERNALFIELDOFFICEAppicationappr doesnot warfalifoT olds legal

°o"si"$o°a's°2°pr

fnany,areattached. 00N0m0NSOFAPPROVALATTACHED

Title 18U.S.C.Section1001andTitle43 U.S.C.Section1212,make ita crime foranypersonknowinglyandwillfullytomaketoany departmentor agencyofthe UnitedStatesanyfalse,fictitiousor fraudulentstatementsor representationsasto anymatterwithin itsjurisdiction.(Continued on page 2) *(Ïnstructionon page 2)

NOTICEOFAPPROVAL MM2 2 2009 NOS N'"9DEC22 2009DIV.0F0lk GAS&MININGE 1, g

Page 43: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

O OUNITED STATES DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT• • VERNAL FIELD OFFICE

' 170 South 500 East VERNAL, UT 84078 (435) 781-4401

CONDITIONS OF APPROVAL FOR APPLICATIONFOR PERMITTO DRILL

Company: Newfield Production Company Location: NWSE, Sec. 21, TSS, R16E

Well No: Federal 10-21-8-16 Lease No: UTU-69060

API No: 43-013-50033 Agreement: Greater Monument Butte (GR)

OFFICE NUMBER: (435) 781-4400OFFICE FAX NUMBER: (435) 781-3420

A COPY OF THESE CONDITIONS SHALL BE FURNISHED TO YOURFIELD REPRESENTATIVE TO INSURE COMPLIANCE

All lease and/or unit operations are to be conducted in such a manner that full compliance is made with theapplicable laws, regulations (43 CFR Part 3160), and this approved Application for Permit to Drill includingSurface and Downhole Conditions of Approval. The operator is considered fully responsible for the actions

of his subcontractors. A copy of the approved APD must be on location during construction, drilling, and

completion operations. This permit is approved for a two (2) year period, or until lease expiration,

whichever occurs first. An additional extension, up to two (2) years, may be applied for by sundry

notice prior to expiration.

NOTIFICATION REQUIREMENTS

Location Construction - Forty-Eight (48) hours prior to construction of locatio¾(Notify Environmental Scientist) access roads.

Location Completion - Prior to moving on the drilling rig.

(Notify Environmental Scientist)

Spud Notice -Twenty-Four (24) hours prior to spudding the well.

(Notify Petroleum Engineer)

Casing String & Cementing - Twenty-Four (24) hours prior to running casing and

(Notify Supv. Petroleum Tech.) cementing all casing strings to: ut vn [email protected].

P & Related Equipment Tests -Twenty-Four (24) hours prior to initiating pressure tests.

(Notify Supv. Petroleum Tech.)

First Production Notice - Within Five (5) business days after new well begins or

(Notify Petroleum Engineer) production resumes after well has been off production formore than ninety (90) days.

DEC22 2009DIV.OFOlL,GAS&

Page 44: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

O O Page 2 of 9Well: Federal 10-21-8-16

12/9/2009

SURFACE USE PROGRAMCONDITIONS OF APPROVAL (COAs)

• All new and replacement internal combustion gas field engines of less than or equal to 300 design-rated horsepower must not emit more than 2 gms of NOx per horsepower-hour. This requirement

does not apply to gas field engines of less than or equal to 40 design-rated horsepower.

• All and replacement internal combustion gas field engines of greater than 300 design ratedhorsepower must not emit more than 1.0 gms of NOx per horsepower-hour.

• If there is an active Gilsonite mining operation within 2 miles of the well location, operator shallnotify the Gilsonite operator at least 48 hours prior to any blasting during construction.

• If paleontological materials are uncovered during construction, the operator is to immediately stopwork and contact the Authorized Officer (AO). A determination will be made by the AO as to whatmitigation may be necessary for the discovered paleontologic material before construction cancontinue.

SITE SPECIFIC COAs:

CONDITIONS OF APPROVAL:

• Construction and drilling is not allowed from May 1 - June 15 to minimize impacts during mountain plovernesting.

• Construction and drilling is not allowed from March 1 - August 31 to minimize impacts during burrowingowl nesting.

• If it is anticipated that.construction or drilling will occur during any of the given timing restrictions, a BLM orqualified biologist shall be notified so surveys can be conducted. Depending upon the results of the surveys,permission to proceed may or may not be granted by the BLM Authorized Officer.

Reclamation

Interim Reclamation:

Interim reclamation of the surface environment shall take place after drilling and completion and the well isplaced into production. At a minimum, this will include the stabilization of the soil surface during construction,re-contouring of the unused pad area, and the reserve pit to the original contour to the extent possible, and the re-

spreading of the top soil after re-contouring takes place, up to the rig anchor points and any area not needed forproduction. Buried pipelines will be re-contoured, the salvaged topsoil redistributed and reseeded. The outside

borrow of the access road will have the top soil salvaged and re-spread and reseeded. The area will be reseeded

using appropriate seeding methods, which includes, but is not limited to, the drill seeding method (see below).Any adjustments, due to site specific production concerns, to the reclamation COAs in this document can besubmitted on Sundry form 3160-5.

The reclamation objective is to establish a desired self-perpetuating diverse plant community. The objective is to

attain 75% basal cover based on similar undisturbed adjacent native vegetativegggogprised of

DEC22 2009DIV.0FOIL,GAS&

Page 45: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

O O Page 3 of 9Well: Federal 10-21-8-16

12/9/2009

desired species and/or seeded species within 5 years of initial reclamation action. However if after three (3)growing seasons there is less than 30% of the basal cover based on similar undisturbed native vegetative

community, then the Authorized Officer may require additional seeding efforts.

Topsoil will be segregated from the subsoil (without mixing them), stockpiled separately from other soilmaterials, and maintained for future use in rehabilitating the locations.

• Topsoil piles stored beyond one growing season will be stabilized and seeded to prevent erosion.

• Topsoil storage areas will be identified with appropriate signage, so it is easily identifiable where topsoil is onlocation.

• Noxious and invasive weeds will be inventoried and monitored. Noxious and invasive weeds will be controlledthrough integrated weed management including chemical, mechanical, and biological control methods. Anapproved Pesticide Use Proposal (PUP) is required for all herbicide applications.

• All trash and waste materials not needed for production will be removed immediately.

• Earth work for interim and final reclamation must be completed within 6 months following well completion or

well plugging (weather permitting).

• Salvaged topsoil will be re-distributed evenly, and to pre-disturbance depths, over the surfaces to be revegetated.

• The soil surface will be prepared to provide a seedbed for re-establishment of desirable vegetation. Sitepreparation may include gouging, scarifying, dozer track-walking, mulching, hydro mulching, contour

furrowing, water terracing, fertilizing, disking, soil additives or other approved methods. The seedbed

preparations will be determined to accomplish the reclamation objectives above.

• The seeding contractor will provide all seed tags to the appropriate SMA prior to seeding efforts.

• Seeding will occur after August 15 and prior to winter freezing of the soil.

• Drill seeding will be used except in areas where topography or substrate composition (rock) precludes the use of

the drill. If drill seeding is not possible, broadcast seeding will be implemented. If the broadcast method is used(such as on slopes of 40 percent or greater), the seed rates established for drill seeding will be doubled and seedwill be immediately covered to prevent seed desiccation or predation by birds or rodents. The seeds can becovered in several ways including spreading and crimping straw over the seeded area, raking the area by hand, ordragging a chain or chain-linked fence over the seeded area.

• Any altered drainages or water courses will be stabilized through rip rap, berming, seeding, matting, or otherapproved methods, and will be reconstructed to have the characteristics and features of nearby functionaldrainages. Any disturbance to "dashed line" drainages as depicted on USGS 1:24,000 topographic maps will becoordinated with the corps of engineers prior to disturbance.

Final Reclamation:

Final Reclamation will be similar to interim reclamation except, all disturbance associated with the well location,access road and pipeline will be reclaimed. The seed mix may include more shrubs and native species. The visual

composition will be reestablished to blend with the natural surroundings through re-co to eæg.

DEC22 2009DIV.0F OIL,GAS&

Page 46: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Page 4 of 9Well: Federal 10-21-8-16

12/9/2009

e After pipeline installation is complete, all disturbed areas will be reseeded. The seed mixtures to be used will besimilar to the vegetation of the surrounding areas and may consist of grasses, forbs, or shrubs. A recommended

seed mixture is provided in the table below.

Monitoring:

• The initial monitoring report will include but is not limited to: when the re-contouring and seeding was

completed. The seed applied, the amounts, and the depth of application. Seedbed preparation such as disking ,

mulching, etc. Seed application such as drilling or broadcast seeding. Are there any soil amendments,fertilizers, watering, etc. The amounts of noxious and invasive weeds. Are any fencing requirenients needed.

• Prior to any surface disturbance, vegetative monitoring locations and reference sites will be identified by theoperator and approved by the BLM Authorized Officer.

• Vegetation monitoring protocol will be developed by the operator and approved by the BLM Authorized Officer

prior to implementation of re-vegetation techniques and will be designed to monitor % basal vegetative cover.

• Reclamation areas will be inspected annually and monitored to document location and extent of areas with

successful re-vegetation. Monitoring will continue until the site is considered a success by the authorized officer

and the objectives established in the Green River District Guidelines. A reclamation report will be submitted

electronically to the Authorized Officer by March 31 of each year.

• On Federal lands, the reclamation objective will be a vegetation community that within 5 years is comprised of

desired and/or seeded species, where the basal vegetative cover is 75 percent of a similar undisturbed adjacentnative vegetation community. If after 3 years basal cover is less than 30 percent, then additional seeding and

reclamation efforts may be required.

Seed mix (Interim and Final Reclamation):

Common name Latin name lbs/acre Recommended seedplantingdepth

Squirreltail grass Elymus elymoides 3.0 ¼ - ½"Siberian wheatgrass. Agropyron fragile 1.0 ½"Shadscale saltbush Atriplex confertifolia 2.0 ½"Four-wing saltbush Atriplex canescens 2.0 ½"Gardner's saltbush Atriplex gardneri 2.0 ½"Scarlet globemallow Sphaeralcea coccinea 1.0 ¼ - ¼"

• All pounds are pure live seed.• All seed and mulch will be certified weed free.• Rates are set for drill seeding; double rate if broadcasting.• Reseeding may be required if initial seeding is not successful.

RECEIVEDDEC22 2009

DIV.0FOIL,GAS&

Page 47: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

- O O Page 5 of 9Well: Federal 10-21-8-16

12/9/2009

DOWNHOLE PROGRAMCONDITIONS OF APPROVAL (COAs)

SITE SPECIFIC DOWNHOLE COAs:

• Newfield Production Co. shall adhere to all referenced requirements in the SOP (version: June 24,2008) ) along with all Oil and Gas rules and requirements listed in the Code of Federal Regulationsand all Federal Onshore Oil and Gas Orders.

All provisions outlined in Onshore Oil & Gas Order #2 Drilling Operations shall be strictly adheredto. The following items are emphasized:

DRILLING/COMPLETION/PRODUCING OPERATING STANDARDS

• The spud date and time shall be reported orally to Vernal Field Office within 24 hours of spudding.

• Notify Vernal Field Office Supervisory Petroleum Engineering Technician at least 24 hours inadvance of casing cementing operations and BOPE & casing pressure tests.

• All requirements listed in Onshore Order #2 III. E. Special Drilling Operations are applicable for airdrilling of surface hole.

• Blowout prevention equipment (BOPE) shall remain in use until the well is completed or abandoned.Closing unit controls shall remain unobstructed and readily accessible at all times. Choke manifoldsshall be located outside of the rig substructure.

• All BOPE components shall be inspected daily and those inspections shall be recorded in the dailydrilling report. Components shall be operated and tested as required by Onshore Oil & Gas OrderNo. 2 to insure good mechanical working order. All BOPE pressure tests shall be performed by atest pump with a chart recorder and NOT' by the rig pumps. Test shall be reported in the driller'slog.

• BOP drills shall be initially conducted by each drilling crew within 24 hours of drilling out fromunder the surface casing and weekly thereafter as specified in Onshore Oil & Gas Order No. 2.

• Casing pressure tests are required before drilling out from under all casing strings set and cementedin place.

• No aggressive/fresh hard-banded drill pipe shall be used within casing.

• Cement baskets shall not be run on surface casing.

• The operator must report all shows of water or water-bearing sands to the If flowing water isencountered it must be sampled, analyzed, and a copy of the analyses sub i VernalField Office DEC22 2009

DIV.0FOlL,GAS&

Page 48: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Page 6 of 9Well: Federal 10-21-8-16

12/9/2009

• The operator must report encounters of all non oil & gas mineral resources (such as Gilsonite, tarsands, oil shale, trona, etc.) to the Vernal Field Office, in writing, within 5 working days of eachencounter. Each report shall include the well name/number, well location, date and depth (from KBor GL) of encounter, vertical footage of the encounter and, the name of the person making the report(along with a telephone number) should the BLM need to obtain additional information.

• A complete set of angular deviation and directional surveys of a directional well will be submitted tothe Vernal BLM office engineer within 30 days of the completion of the well.

• While actively drilling, chronologic drilling progress reports shall be filed directly with the BLM,Vernal Field Office on a weekly basis in sundry, letter format or e-mail to the Petroleum Engineersuntil the well is completed.

• A cement bond log (CBL) will be run from the production casing shoe to the top of cement and shallbe utilized to determine the bond quality for the production casing. Submit a field copy of the CBLto this office.

• Please submit an electronic copy of all other logs run on this well in LAS format toUT [email protected]. This submission will supersede the requirement for submittal ofpaper logs to the BLM.

• There shall be no deviation from the proposed drilling, completion, and/or workover program asapproved. Safe drilling and operating practices must be observed. Any changes in operation must

have prior approval from the BLM Vernal Field Office.

RECElVEDDEC22 2009

DIV.0FOIL,GAS&

Page 49: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

· O O Page 7 of 9Well: Federal 10-21-8-16

12/9/2009

OPERATING REQUIREMENT REMINDERS:

• All wells, whether drilling, producing, suspended, or abandoned, shall be identified in accordancewith 43 CFR 3162.6. There shall be a sign or märker with the name of the operator, lease serialnumber, well number, and surveyed description of the well.

• In accordance with 43 CFR 3162.4-3, this well shall be reported on the "Monthly Report ofOperations" (Oil and Gas Operations Report ((OGOR)) starting with the month in which operationscommence and continue each month until the well is physically plugged and abandoned. This reportshall be filed in duplicate, directly with the Minerals Management Service, P.O. Box 17110, Denver,Colorado 80217-0110, or call 1-800-525-7922 (303) 231-3650 for reporting information.

• Should the well be successfully completed for production, the BLM Vernal Field office must benotified when it is placed in a producing status. Such notification will be by written communicationand must be received in this office by not later than the fifth business day following the date onwhich the well is placed on production. The notification shall provide, as a minimum, the followinginformational items:

o Operator name, address, and telephone number.

o Well name and number.

o Well location (¼¼,Sec., Twn, Rng, and P.M.).

o Date well was placed in a producing status (date of first production for which royalty will bepaid).

o The nature of the well's production, (i.e., crude oil, or crude oil and casing head gas, ornatural gas and entrained liquid hydrocarbons).

o The Federal or Indian lease prefix and number on which the well is located; otherwise thenon-Federal or non-Indian land category, i.e., State or private.

o Unit agreement and/or participating area name and number, if applicable.

o Communitization agreement number, if applicable.

• Any venting or flaring of gas shall be done in accordance with Notice to Lessees (NTL) 4A andneeds prior approval from the BLM Vernal Field Office.

• All undesirable events (fires, accidents, blowouts, spills, discharges) as specified in NTL 3A will bereported to the BLM, Vernal Field Office. Major events, as defined in NTL3A, shall be reportedverbally within 24 hours, followed by a written report within 15 days. "Other than Major Events"will be reported in writing within 15 days. "Minor Events" will be reported on the Monthly Reportof Operations and Production. RECEIVED

DEC22 2009DIV.0FOIL,GAS&

Page 50: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Page 8 of 9Well: Federal 10-21-8-16

12/9/2009

• Whether the well is completed as a dry hole or as a producer, "Well Completion and RecompletionReport and Log" (BLM Form 3160-4) shall be submitted not later than 30 days after completion ofthe well or after completion of operations being performed, in accordance with 43 CFR 3162.4-1.

Two copies of all logs run, core descriptions, and all other surveys or data obtained and compiledduring the drilling, workover, and/or completion operations, shall be filed on BLM Form 3160-4.

Submit with the well completion report a geologic report including, at a minimum, formation tops,and a summary and conclusions. Also include deviation surveys, sample descriptions, strip logs,core data, drill stem test data, and results of production tests if performed. Samples (cuttings, fluid,and/or gas) shall be submitted only when requested by the BLM, Vernal Field Office.

• All off-lease storage, off-lease measurement, or commingling on-lease or off-lease, shall have priorwritten approval from the BLM Vernal Field Office.

• Oil and gas meters shall be calibrated in place prior to any deliveries. The BLM Vernal Field OfficePetroleum Engineers will be provided with a date and time for the initial meter calibration and allfuture meter proving schedules. A copy of the meter calibration reports shall be submitted to theBLM Vernal Field Office. All measurement facilities will conform to the API standards for liquidhydrocarbons and the AGA standards for natural gas measurement. All measurement points shall beidentified as the point of sale or allocation for royalty purposes.

• A schematic facilities diagram as required by Onshore Oil & Gas Order No. 3 shall be submitted tothe BLM Vernal Field Office within 30 days of installation or first production, whichever occurs

first. All site security regulations as specified in Onshore Oil & Gas Order No. 3 shall be adhered to.All product lines entering and leaving hydrocarbon storage tanks will be effectively sealed inaccordance with Onshore Oil & Gas Order No. 3.

• Any additional construction, reconstruction, or alterations of facilities, including roads, gatheringlines, batteries, etc., which will result in the disturbance of new ground, shall require the filing of asuitable plan and need prior approval of the BLM Vernal Field Office. Emergency approval may beobtained orally, but such approval does not waive the written report requirement.

• No location shall be constructed or moved, no well shall be plugged, and no drilling or workover

equipment shall be removed from a well to be placed in a suspended status without prior approval ofthe BLM Vernal Field Office. If operations are to be suspended for more than 30 days, priorapproval of the BLM Vernal Field Office shall be obtained and notification given before resumptionof operations.

• Pursuant to Onshore Oil & Gas Order No. 7, this is authorization for pit disposal of water producedfrom this well for a period of 90 days from the date of initial production. A permanent disposalmethod must be approved by this office and in operation prior to the end of this 90-day period. Inorder to meet this deadline, an application for the proposed permanent disposal method shall besubmitted along with any necessary water analyses, as soon as possible, but no later than 45 daysafter the date of first production. Any method of disposal which has not been approved prior to theend of the authorized 90-day period will be considered as an Incident of Nonc gggill begrounds for issuing a shut-in order until an acceptable manner for disposing o sai water is providedand approved by this office DEC22 2009

DIV.0FOlL,GAS&

Page 51: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

O O Page 9 of 9Well: Federal 10-21-8-16

12/9/2009

• Unless the plugging is to take place immediately upon receipt of oral approval, the Field OfficePetroleum Engineers must be notified at least 24 hours in advance of the plugging of the well, inorder that a representative may witness plugging operations. If a well is suspended or abandoned, allpits must be fenced immediately until they are backfilled. The "Subsequent Report ofAbandonment" (Form BLM 3160-5) must be submitted within 30 days after the actual plugging ofthe well bore, showing location of plugs, amount of cement in each, and amount of casing left inhole, and the current status of the surface restoration.

RECEIVEDDEC22 2009

DIV.OFOIL,GAS&

Page 52: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Form3160-3FORM APPROVED(August2007)OMBNo.1004-0137

• ExpiresJuly31,2010UNITED STATESDEPARTMENTOF THE INTERIOR 5. LeaseSerialNo.BUREAUOF LAND MANAGEMENT UTU-69060

APPUCATION FOR PERMIT TO DRILL OR REENTER 6. IfInd ,Allotee orTribeName

la. Typeof work: DRILL O REENTER 2 ÏfUnitor CAAgreement,NameandNo.

8. Lease Nameand WellNo.lb. TypeofWell: 0 I Well GasWell Other SingleZone MultipleZone Federal 10-21-8-162. Nameof0perator Newfield Production Company 9. API WellNo.3a. Address Route #3 Box 3630, Myton UT 84052 3b. PhoneNo.(include area code) 10 FiefdantfPool,orExploratory(435) 646-3721

Monument Butte4. Locationof Well(Reportlocationclearly and in acœrdance with anyMaterequirements.*) 11 Seo.,T.R. M. or Blk.andSurveyorAreaAt surface NWISE 2090' FSL 1941' FELSec. 21, T8S R16EAt proposedprod.zone

14. Distancein milesanddirectionfrom nearesttownorpostoffice Ïi Countyor Parish 13.StateApproximately9.4 miles southwest ofMyton, UT Duchesne UT15. Distancefromproposed*16.No.of acresin lease 17. SpacingUnitdedicatedto thiswelllocationtonearest

propertyor leaseline,it. Approx. 699' f/lse, NA' flunit1130.40(Alsotonearestdrig.unit line,ifany) 40 Acres

18.Distancefrompo osedlocation* 19.ProposedDepth 20. BLM/BIABondNo.on fileapppnlotoro this

eng, ompleted, Approx. 2005' 6,690' WYBOOO49321. Elevations(ShowwhetherDF,KDB,RT,4 etc.) 22. Appr imatedateworkwillstart* 23. Estimatedduration5450' GL

(7) days from SPUD to rig release24. Attachments

Thefollowing,completedinaccordancewith therequirementsof OnshoreOilandGasOrderNo.l, mustbe attachedto thiiform:1. Wellplatcertifiedby a registeredsurveyor. 4. Bond tocover the operationsunlesscovered byan existingbondon file (see2. ADrillingPlan. Item20 above).3. A SurfaceUsePlan (if the location is on National Forest SystemLands, the 5. OperatorcertificationSUPO mustbe filedwith theappropriateForest ServiceOffice) 6. Suchothersite specificinfórmationand/orplansas mayberequiredbythe25 S Nme (ePrint ed) Da

TitleRegulatory Specialist

Approyedby (Si Name (Printed/Typed) Date

Title ASSIS eld ager officeVERNALFIELDOFFICEAppicationappr doesnot warfalifoT olds legal

°o"si"$o°a's°2°pr

fnany,areattached. 00N0m0NSOFAPPROVALATTACHED

Title 18U.S.C.Section1001andTitle43 U.S.C.Section1212,make ita crime foranypersonknowinglyandwillfullytomaketoany departmentor agencyofthe UnitedStatesanyfalse,fictitiousor fraudulentstatementsor representationsasto anymatterwithin itsjurisdiction.(Continued on page 2) *(Ïnstructionon page 2)

NOTICEOFAPPROVAL MM2 2 2009 NOS N'"9DEC22 2009DIV.0F0lk GAS&MININGE 1, g

Page 53: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

O OUNITED STATES DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT• • VERNAL FIELD OFFICE

' 170 South 500 East VERNAL, UT 84078 (435) 781-4401

CONDITIONS OF APPROVAL FOR APPLICATIONFOR PERMITTO DRILL

Company: Newfield Production Company Location: NWSE, Sec. 21, TSS, R16E

Well No: Federal 10-21-8-16 Lease No: UTU-69060

API No: 43-013-50033 Agreement: Greater Monument Butte (GR)

OFFICE NUMBER: (435) 781-4400OFFICE FAX NUMBER: (435) 781-3420

A COPY OF THESE CONDITIONS SHALL BE FURNISHED TO YOURFIELD REPRESENTATIVE TO INSURE COMPLIANCE

All lease and/or unit operations are to be conducted in such a manner that full compliance is made with theapplicable laws, regulations (43 CFR Part 3160), and this approved Application for Permit to Drill includingSurface and Downhole Conditions of Approval. The operator is considered fully responsible for the actions

of his subcontractors. A copy of the approved APD must be on location during construction, drilling, and

completion operations. This permit is approved for a two (2) year period, or until lease expiration,

whichever occurs first. An additional extension, up to two (2) years, may be applied for by sundry

notice prior to expiration.

NOTIFICATION REQUIREMENTS

Location Construction - Forty-Eight (48) hours prior to construction of locatio¾(Notify Environmental Scientist) access roads.

Location Completion - Prior to moving on the drilling rig.

(Notify Environmental Scientist)

Spud Notice -Twenty-Four (24) hours prior to spudding the well.

(Notify Petroleum Engineer)

Casing String & Cementing - Twenty-Four (24) hours prior to running casing and

(Notify Supv. Petroleum Tech.) cementing all casing strings to: ut vn [email protected].

P & Related Equipment Tests -Twenty-Four (24) hours prior to initiating pressure tests.

(Notify Supv. Petroleum Tech.)

First Production Notice - Within Five (5) business days after new well begins or

(Notify Petroleum Engineer) production resumes after well has been off production formore than ninety (90) days.

DEC22 2009DIV.OFOlL,GAS&

Page 54: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

O O Page 2 of 9Well: Federal 10-21-8-16

12/9/2009

SURFACE USE PROGRAMCONDITIONS OF APPROVAL (COAs)

• All new and replacement internal combustion gas field engines of less than or equal to 300 design-rated horsepower must not emit more than 2 gms of NOx per horsepower-hour. This requirement

does not apply to gas field engines of less than or equal to 40 design-rated horsepower.

• All and replacement internal combustion gas field engines of greater than 300 design ratedhorsepower must not emit more than 1.0 gms of NOx per horsepower-hour.

• If there is an active Gilsonite mining operation within 2 miles of the well location, operator shallnotify the Gilsonite operator at least 48 hours prior to any blasting during construction.

• If paleontological materials are uncovered during construction, the operator is to immediately stopwork and contact the Authorized Officer (AO). A determination will be made by the AO as to whatmitigation may be necessary for the discovered paleontologic material before construction cancontinue.

SITE SPECIFIC COAs:

CONDITIONS OF APPROVAL:

• Construction and drilling is not allowed from May 1 - June 15 to minimize impacts during mountain plovernesting.

• Construction and drilling is not allowed from March 1 - August 31 to minimize impacts during burrowingowl nesting.

• If it is anticipated that.construction or drilling will occur during any of the given timing restrictions, a BLM orqualified biologist shall be notified so surveys can be conducted. Depending upon the results of the surveys,permission to proceed may or may not be granted by the BLM Authorized Officer.

Reclamation

Interim Reclamation:

Interim reclamation of the surface environment shall take place after drilling and completion and the well isplaced into production. At a minimum, this will include the stabilization of the soil surface during construction,re-contouring of the unused pad area, and the reserve pit to the original contour to the extent possible, and the re-

spreading of the top soil after re-contouring takes place, up to the rig anchor points and any area not needed forproduction. Buried pipelines will be re-contoured, the salvaged topsoil redistributed and reseeded. The outside

borrow of the access road will have the top soil salvaged and re-spread and reseeded. The area will be reseeded

using appropriate seeding methods, which includes, but is not limited to, the drill seeding method (see below).Any adjustments, due to site specific production concerns, to the reclamation COAs in this document can besubmitted on Sundry form 3160-5.

The reclamation objective is to establish a desired self-perpetuating diverse plant community. The objective is to

attain 75% basal cover based on similar undisturbed adjacent native vegetativegggogprised of

DEC22 2009DIV.0FOIL,GAS&

Page 55: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

O O Page 3 of 9Well: Federal 10-21-8-16

12/9/2009

desired species and/or seeded species within 5 years of initial reclamation action. However if after three (3)growing seasons there is less than 30% of the basal cover based on similar undisturbed native vegetative

community, then the Authorized Officer may require additional seeding efforts.

Topsoil will be segregated from the subsoil (without mixing them), stockpiled separately from other soilmaterials, and maintained for future use in rehabilitating the locations.

• Topsoil piles stored beyond one growing season will be stabilized and seeded to prevent erosion.

• Topsoil storage areas will be identified with appropriate signage, so it is easily identifiable where topsoil is onlocation.

• Noxious and invasive weeds will be inventoried and monitored. Noxious and invasive weeds will be controlledthrough integrated weed management including chemical, mechanical, and biological control methods. Anapproved Pesticide Use Proposal (PUP) is required for all herbicide applications.

• All trash and waste materials not needed for production will be removed immediately.

• Earth work for interim and final reclamation must be completed within 6 months following well completion or

well plugging (weather permitting).

• Salvaged topsoil will be re-distributed evenly, and to pre-disturbance depths, over the surfaces to be revegetated.

• The soil surface will be prepared to provide a seedbed for re-establishment of desirable vegetation. Sitepreparation may include gouging, scarifying, dozer track-walking, mulching, hydro mulching, contour

furrowing, water terracing, fertilizing, disking, soil additives or other approved methods. The seedbed

preparations will be determined to accomplish the reclamation objectives above.

• The seeding contractor will provide all seed tags to the appropriate SMA prior to seeding efforts.

• Seeding will occur after August 15 and prior to winter freezing of the soil.

• Drill seeding will be used except in areas where topography or substrate composition (rock) precludes the use of

the drill. If drill seeding is not possible, broadcast seeding will be implemented. If the broadcast method is used(such as on slopes of 40 percent or greater), the seed rates established for drill seeding will be doubled and seedwill be immediately covered to prevent seed desiccation or predation by birds or rodents. The seeds can becovered in several ways including spreading and crimping straw over the seeded area, raking the area by hand, ordragging a chain or chain-linked fence over the seeded area.

• Any altered drainages or water courses will be stabilized through rip rap, berming, seeding, matting, or otherapproved methods, and will be reconstructed to have the characteristics and features of nearby functionaldrainages. Any disturbance to "dashed line" drainages as depicted on USGS 1:24,000 topographic maps will becoordinated with the corps of engineers prior to disturbance.

Final Reclamation:

Final Reclamation will be similar to interim reclamation except, all disturbance associated with the well location,access road and pipeline will be reclaimed. The seed mix may include more shrubs and native species. The visual

composition will be reestablished to blend with the natural surroundings through re-co to eæg.

DEC22 2009DIV.0F OIL,GAS&

Page 56: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Page 4 of 9Well: Federal 10-21-8-16

12/9/2009

e After pipeline installation is complete, all disturbed areas will be reseeded. The seed mixtures to be used will besimilar to the vegetation of the surrounding areas and may consist of grasses, forbs, or shrubs. A recommended

seed mixture is provided in the table below.

Monitoring:

• The initial monitoring report will include but is not limited to: when the re-contouring and seeding was

completed. The seed applied, the amounts, and the depth of application. Seedbed preparation such as disking ,

mulching, etc. Seed application such as drilling or broadcast seeding. Are there any soil amendments,fertilizers, watering, etc. The amounts of noxious and invasive weeds. Are any fencing requirenients needed.

• Prior to any surface disturbance, vegetative monitoring locations and reference sites will be identified by theoperator and approved by the BLM Authorized Officer.

• Vegetation monitoring protocol will be developed by the operator and approved by the BLM Authorized Officer

prior to implementation of re-vegetation techniques and will be designed to monitor % basal vegetative cover.

• Reclamation areas will be inspected annually and monitored to document location and extent of areas with

successful re-vegetation. Monitoring will continue until the site is considered a success by the authorized officer

and the objectives established in the Green River District Guidelines. A reclamation report will be submitted

electronically to the Authorized Officer by March 31 of each year.

• On Federal lands, the reclamation objective will be a vegetation community that within 5 years is comprised of

desired and/or seeded species, where the basal vegetative cover is 75 percent of a similar undisturbed adjacentnative vegetation community. If after 3 years basal cover is less than 30 percent, then additional seeding and

reclamation efforts may be required.

Seed mix (Interim and Final Reclamation):

Common name Latin name lbs/acre Recommended seedplantingdepth

Squirreltail grass Elymus elymoides 3.0 ¼ - ½"Siberian wheatgrass. Agropyron fragile 1.0 ½"Shadscale saltbush Atriplex confertifolia 2.0 ½"Four-wing saltbush Atriplex canescens 2.0 ½"Gardner's saltbush Atriplex gardneri 2.0 ½"Scarlet globemallow Sphaeralcea coccinea 1.0 ¼ - ¼"

• All pounds are pure live seed.• All seed and mulch will be certified weed free.• Rates are set for drill seeding; double rate if broadcasting.• Reseeding may be required if initial seeding is not successful.

RECEIVEDDEC22 2009

DIV.0FOIL,GAS&

Page 57: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

- O O Page 5 of 9Well: Federal 10-21-8-16

12/9/2009

DOWNHOLE PROGRAMCONDITIONS OF APPROVAL (COAs)

SITE SPECIFIC DOWNHOLE COAs:

• Newfield Production Co. shall adhere to all referenced requirements in the SOP (version: June 24,2008) ) along with all Oil and Gas rules and requirements listed in the Code of Federal Regulationsand all Federal Onshore Oil and Gas Orders.

All provisions outlined in Onshore Oil & Gas Order #2 Drilling Operations shall be strictly adheredto. The following items are emphasized:

DRILLING/COMPLETION/PRODUCING OPERATING STANDARDS

• The spud date and time shall be reported orally to Vernal Field Office within 24 hours of spudding.

• Notify Vernal Field Office Supervisory Petroleum Engineering Technician at least 24 hours inadvance of casing cementing operations and BOPE & casing pressure tests.

• All requirements listed in Onshore Order #2 III. E. Special Drilling Operations are applicable for airdrilling of surface hole.

• Blowout prevention equipment (BOPE) shall remain in use until the well is completed or abandoned.Closing unit controls shall remain unobstructed and readily accessible at all times. Choke manifoldsshall be located outside of the rig substructure.

• All BOPE components shall be inspected daily and those inspections shall be recorded in the dailydrilling report. Components shall be operated and tested as required by Onshore Oil & Gas OrderNo. 2 to insure good mechanical working order. All BOPE pressure tests shall be performed by atest pump with a chart recorder and NOT' by the rig pumps. Test shall be reported in the driller'slog.

• BOP drills shall be initially conducted by each drilling crew within 24 hours of drilling out fromunder the surface casing and weekly thereafter as specified in Onshore Oil & Gas Order No. 2.

• Casing pressure tests are required before drilling out from under all casing strings set and cementedin place.

• No aggressive/fresh hard-banded drill pipe shall be used within casing.

• Cement baskets shall not be run on surface casing.

• The operator must report all shows of water or water-bearing sands to the If flowing water isencountered it must be sampled, analyzed, and a copy of the analyses sub i VernalField Office DEC22 2009

DIV.0FOlL,GAS&

Page 58: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Page 6 of 9Well: Federal 10-21-8-16

12/9/2009

• The operator must report encounters of all non oil & gas mineral resources (such as Gilsonite, tarsands, oil shale, trona, etc.) to the Vernal Field Office, in writing, within 5 working days of eachencounter. Each report shall include the well name/number, well location, date and depth (from KBor GL) of encounter, vertical footage of the encounter and, the name of the person making the report(along with a telephone number) should the BLM need to obtain additional information.

• A complete set of angular deviation and directional surveys of a directional well will be submitted tothe Vernal BLM office engineer within 30 days of the completion of the well.

• While actively drilling, chronologic drilling progress reports shall be filed directly with the BLM,Vernal Field Office on a weekly basis in sundry, letter format or e-mail to the Petroleum Engineersuntil the well is completed.

• A cement bond log (CBL) will be run from the production casing shoe to the top of cement and shallbe utilized to determine the bond quality for the production casing. Submit a field copy of the CBLto this office.

• Please submit an electronic copy of all other logs run on this well in LAS format toUT [email protected]. This submission will supersede the requirement for submittal ofpaper logs to the BLM.

• There shall be no deviation from the proposed drilling, completion, and/or workover program asapproved. Safe drilling and operating practices must be observed. Any changes in operation must

have prior approval from the BLM Vernal Field Office.

RECElVEDDEC22 2009

DIV.0FOIL,GAS&

Page 59: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

· O O Page 7 of 9Well: Federal 10-21-8-16

12/9/2009

OPERATING REQUIREMENT REMINDERS:

• All wells, whether drilling, producing, suspended, or abandoned, shall be identified in accordancewith 43 CFR 3162.6. There shall be a sign or märker with the name of the operator, lease serialnumber, well number, and surveyed description of the well.

• In accordance with 43 CFR 3162.4-3, this well shall be reported on the "Monthly Report ofOperations" (Oil and Gas Operations Report ((OGOR)) starting with the month in which operationscommence and continue each month until the well is physically plugged and abandoned. This reportshall be filed in duplicate, directly with the Minerals Management Service, P.O. Box 17110, Denver,Colorado 80217-0110, or call 1-800-525-7922 (303) 231-3650 for reporting information.

• Should the well be successfully completed for production, the BLM Vernal Field office must benotified when it is placed in a producing status. Such notification will be by written communicationand must be received in this office by not later than the fifth business day following the date onwhich the well is placed on production. The notification shall provide, as a minimum, the followinginformational items:

o Operator name, address, and telephone number.

o Well name and number.

o Well location (¼¼,Sec., Twn, Rng, and P.M.).

o Date well was placed in a producing status (date of first production for which royalty will bepaid).

o The nature of the well's production, (i.e., crude oil, or crude oil and casing head gas, ornatural gas and entrained liquid hydrocarbons).

o The Federal or Indian lease prefix and number on which the well is located; otherwise thenon-Federal or non-Indian land category, i.e., State or private.

o Unit agreement and/or participating area name and number, if applicable.

o Communitization agreement number, if applicable.

• Any venting or flaring of gas shall be done in accordance with Notice to Lessees (NTL) 4A andneeds prior approval from the BLM Vernal Field Office.

• All undesirable events (fires, accidents, blowouts, spills, discharges) as specified in NTL 3A will bereported to the BLM, Vernal Field Office. Major events, as defined in NTL3A, shall be reportedverbally within 24 hours, followed by a written report within 15 days. "Other than Major Events"will be reported in writing within 15 days. "Minor Events" will be reported on the Monthly Reportof Operations and Production. RECEIVED

DEC22 2009DIV.0FOIL,GAS&

Page 60: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Page 8 of 9Well: Federal 10-21-8-16

12/9/2009

• Whether the well is completed as a dry hole or as a producer, "Well Completion and RecompletionReport and Log" (BLM Form 3160-4) shall be submitted not later than 30 days after completion ofthe well or after completion of operations being performed, in accordance with 43 CFR 3162.4-1.

Two copies of all logs run, core descriptions, and all other surveys or data obtained and compiledduring the drilling, workover, and/or completion operations, shall be filed on BLM Form 3160-4.

Submit with the well completion report a geologic report including, at a minimum, formation tops,and a summary and conclusions. Also include deviation surveys, sample descriptions, strip logs,core data, drill stem test data, and results of production tests if performed. Samples (cuttings, fluid,and/or gas) shall be submitted only when requested by the BLM, Vernal Field Office.

• All off-lease storage, off-lease measurement, or commingling on-lease or off-lease, shall have priorwritten approval from the BLM Vernal Field Office.

• Oil and gas meters shall be calibrated in place prior to any deliveries. The BLM Vernal Field OfficePetroleum Engineers will be provided with a date and time for the initial meter calibration and allfuture meter proving schedules. A copy of the meter calibration reports shall be submitted to theBLM Vernal Field Office. All measurement facilities will conform to the API standards for liquidhydrocarbons and the AGA standards for natural gas measurement. All measurement points shall beidentified as the point of sale or allocation for royalty purposes.

• A schematic facilities diagram as required by Onshore Oil & Gas Order No. 3 shall be submitted tothe BLM Vernal Field Office within 30 days of installation or first production, whichever occurs

first. All site security regulations as specified in Onshore Oil & Gas Order No. 3 shall be adhered to.All product lines entering and leaving hydrocarbon storage tanks will be effectively sealed inaccordance with Onshore Oil & Gas Order No. 3.

• Any additional construction, reconstruction, or alterations of facilities, including roads, gatheringlines, batteries, etc., which will result in the disturbance of new ground, shall require the filing of asuitable plan and need prior approval of the BLM Vernal Field Office. Emergency approval may beobtained orally, but such approval does not waive the written report requirement.

• No location shall be constructed or moved, no well shall be plugged, and no drilling or workover

equipment shall be removed from a well to be placed in a suspended status without prior approval ofthe BLM Vernal Field Office. If operations are to be suspended for more than 30 days, priorapproval of the BLM Vernal Field Office shall be obtained and notification given before resumptionof operations.

• Pursuant to Onshore Oil & Gas Order No. 7, this is authorization for pit disposal of water producedfrom this well for a period of 90 days from the date of initial production. A permanent disposalmethod must be approved by this office and in operation prior to the end of this 90-day period. Inorder to meet this deadline, an application for the proposed permanent disposal method shall besubmitted along with any necessary water analyses, as soon as possible, but no later than 45 daysafter the date of first production. Any method of disposal which has not been approved prior to theend of the authorized 90-day period will be considered as an Incident of Nonc gggill begrounds for issuing a shut-in order until an acceptable manner for disposing o sai water is providedand approved by this office DEC22 2009

DIV.0FOlL,GAS&

Page 61: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

O O Page 9 of 9Well: Federal 10-21-8-16

12/9/2009

• Unless the plugging is to take place immediately upon receipt of oral approval, the Field OfficePetroleum Engineers must be notified at least 24 hours in advance of the plugging of the well, inorder that a representative may witness plugging operations. If a well is suspended or abandoned, allpits must be fenced immediately until they are backfilled. The "Subsequent Report ofAbandonment" (Form BLM 3160-5) must be submitted within 30 days after the actual plugging ofthe well bore, showing location of plugs, amount of cement in each, and amount of casing left inhole, and the current status of the surface restoration.

RECEIVEDDEC22 2009

DIV.OFOIL,GAS&

Page 62: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

7°" United States Department of the InteriorBUREAU OF LAND MANAGEMENT

Green River DistrictVernal Field Office

s, 170 South 500 EastVernal, UT 84078

http://www.blm.gov/ut/st/en/fo/vernal.html

IN REPLY REFER TO: Û ËÛ3M1a6nOdie

C

oOze1r

Newfield Production CompanyRoute 3, Box 3630Myton, UT 84052

Re: Request to Rescind Approved APD

Well No. Federal 10-21-8-16NWSE, Sec. 21, T8S, R16EDuchesne County, UtahLease No. UTU-69060

Dear Ms. Crozier:

The Application for Permit to Drill (APD) for the above-referenced wellwas approved onDecember 15, 2009. This office is rescinding its approval of the referenced ApplicationforPermit to Drill per your request to thisoffice in an email message to Land Law Examiner RobinHansen received on August 27, 2013. Ifyou intend to drill at this location in the future, a newApplication for Permit to Drill must be submitted.

This office requires a letter confirming that no surface disturbance has been made for this drillsite. Any surface disturbance associated with the approved location of thiswell is to berehabilitated. A schedule for this rehabilitation must be submitted to thisoffice. Yourcooperation in this matter is appreciated.

Ifyou have any questions regarding APD processing, please contact Leslie Buhler at (435) 781-3432.

Sincerely,

Assistant Field ManagerLands & Resource

Page 63: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

Division of Oil, Gas and Mining

Operator Change/Name Change Worksheet-for State use only

Effective Date : 112412020 -, FORMER OPERATOR: NEW OPERA TOR: Newfield Production Company Ovintiv Production, Inc.

Groups: Greater MOIIUIDeIIlBulle , ~:<,

WELL INFORMATION: WeU Name See Attached List

Total Well Count: OPERATOR CHANGES DOCUMENTATION: I. Sundry or legal documentation was received from the FORMER operator on : 2. Sundry or legal documentation was received from the NEW operator on: 3. New operator Division of Corporations Business Number:

REVIEW: Receipt of Acceptance of Drilling Procedures for APD on: Reports current for Production/Disposition & Sundries: OPS/SIIT A well(s) reviewed for fuU cost bonding: Approved by Dustin

UIC5 on all disposaVinjection/storage well(s) Approved on: Approved by Dayne Surface Facility(s) included in operator change: State 11-32 Pipetine

Monument Butte St 10-36 GB Fed 13-20-8-17 Call1l8Sback Fed 1-22-8-17 Ashley Fed 8-14-9-15 PIpeline

NEW OPERATOR BOND VERIFICATION: State/fee well(s) covered by Bond Number(s):

DATA ENTRY: Well(s) update in the RBDMS on: Group(s) update in RDBMS on: Surface Facilities update in RBDMS on: Entities Updated in RBDMS on:

COMMENTS:

west Iateral4C SIus Catcher (2-5-3-3) West latent Phase 5 Slug Catcher Bar F SIua Catcher Dart SIui CetdIer Mullins SIu& CatdIer Temporary PnIducecI Water Conditioning Site

Dart Temporary Produced w.rter FacUity EariT ra waterJreatment aclllty

1/1412021 111412021 1/1412021

755627-0143

3/1612020 ____ .... 3/1612020

.--=-=:-__ 91212020 111412021 1212112020 312512020

I

I

Status

2/23/2021

Page 64: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS AND MINING

SUNDRY NOTICES AND REPORTS ON WELLS

Do not use this lonn lor proposals to drill new wells, significantly deepen existing wells below current bottom-hole depth, reenter plugged wells, or to drill horizontsl lstersls. Use APPLICA nON FOR PERMIT TO DRILL form for such proposals.

1. TYPE OF WELl. OIL WELL 0 GAS WELL 0 OTHER ______________________ __

2 . NAM E OF OPERATOR:

Newfield Production Company 3. ADDRESS OF OPERATOR:

4 Waterway Square Place Sl CIT'! The Woodlands SiME TX 21P 77380 4. LOCATION OF WELL

FOOTAGES AT SURFACE:

QTR/OTR, SECTION, TOWNSHIP, RANGE, MERIDIAN:

FORM 9

5. LEASE DESIGNATION AND SERIAL NUMBER'

see attached list 6. IF INDIAN, ALLOTTEE OR TRIBE NAME:

see attached 7 UNIT or CA AGREEMENT NAME'

8. 'Mi:LL NAME and NUMBER '

see attached 9 API NUMBER:

attached 10. FIELD AND POOL, OR WILDCAT:

attached

COUNTY'

STATE:

UTAH

11 . CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

Q] 0 ACIDIZE 0 DEEPEN 0 REPERFORATE CURRENT FORMATION NOTICE OF INTENT

(Submit in fluplir.ate) 0 ALTER CASING 0 fRACTURE TREAT 0 SIDETRACK 1'0 REPAIR WELL

ApproxllTlatA cjijte wOlk Will staft 0 CASING REPAIR 0 NEW CONSTRUCTION 0 TEMPORARIL Y ABANDON

D CHANGE TO PREVIOUS f'LANS fZl OPERATOR CHANGE 0 fUSING Rt:PAIf<

0 CHANGE TUBING 0 PLUG AND ABANDON 0 VENT OR FI.ARE

[ J SUBSEQUENT REPORT 0 GrIANGE WELL NAME 0 PLUG SACK 0 WATER DISPOSAL (Submit Original Form Only)

0 0 0 CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHIJT -OFF Datn of work completion

0 0 0 COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WELL SITE OTHER

0 CONVERT WELL TYPE 0 RECOMPLETE - DIFFERENT FORMATION

12 DESCRIBE PROPOSED OR COMPLETED OPERATIONS, Clearly show all pertinent details including dates , depths, VOlumes, etc,

This sundry is serve as notification of the formal corporate name change of Newfield Production Company to Ovintiv Production Inc, Attached is a list of all wells wells that will be operated under Ovintiv Production Inc effective January 24, 2020,

PREVIOUS NAME: Newfield Producion Company 4 Waterway Square Place Suite 100 The Woodlands, TX 77380 (435)646-4825

(This space ror State U5. only)

(ti/2000)

NEW NAME: Ovintiv Production Inc, 4 Waterway Square Place Suite 100 The Woodlands, TX 77380 (435)646-4825

flT l E Regulatory Manager, Rockies

DATE 3/16/2020

Page 65: FORM 3 STATE OF UTAH DEPARTMENT OF NATURAL … · API NUMBER ASSIGNED 43013500330000 Permit Manager m APPROVAL FORM 3 AMENDED REPORT API Well No: 43013500330000 Received: 5/19/2009fWellW

STATE OF UTAH DEPARTMENT OF NATURAL RESOURCES

DIVISION OF OIL, GAS AND MINING

SUNDRY NOTICES AND REPORTS ON WELLS

Do not use this form lor proposals 10 drill new wells. significantly deepen existing wells below current bottom-hal. depth, reenter plugged wells, or to drill horizontal laterals. Use APPLICATION FOR PERMIT TO DRILL form for such proposals.

1. TYPE OF WEll. OIL WELL 0 GAS WELL 0 OTHER ______________________ __

2. NAME OF OPERATOR:

Newfield Production Company 3. ADDRESS OF OPERATOR:

4 Waterway Square Place SL CIT" The Woodlands smE TX 2iP 77380 4. LOCATION OF WELL

FOOTAGES AT SURFACE:

OTR/OTR. SECTION, TOWNSHIP, RANGE, MERIDIAN:

FORM 9

5. LEASE DESIGNATION AND SERIAL NUMBER

see attached list 6. IF INDIAN. ALLOTTEE OR TRIBE NAME:

see attached 7 UNIT or CA AGREEMENT NAME'

8. V',ELL NAME and NUMBER'

see attached 9 API NUMBER:

attached 10. FIELD AND POOL, OR 'M'-DCAT:

attached

COUNTY'

STATE: UTAH

11 . CHECK APPROPRIATE BOXES TO INDICATE NATURE OF NOTICE, REPORT, OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

121 0 ACIDIZE 0 DEEPEN 0 REPERFORATE CURRENT FORMATION NOTICE OF INTENT

(Submit in Duplicate) 0 ALTER CASING 0 FRACTURE TREAT 0 SIDETRACK 1'0 REPAIR WELL

ApproXimate elale work will start: 0 CASING REPAIR 0 NEW CONSTRUCTION 0 TEMPORARIL Y ABANDON

0 CHANGE TO PREVIOUS PLANS 121 OPF.RATOR CHANGE 0 rUSING REPAlil

0 CHANGE TUBING [J PUJG AND ABANDON D VENT OR FLARE

[J SUBSEQUENT REPORT D OIANGE WELL NAME 0 PLUG BACK 0 WATER DISPOSAL (Submit Original Form Only)

D D 0 CHANGE WELL STATUS PRODUCTION (START/RESUME) WATER SHtH .oF" Of:lln of work completion

0 0 0 COMMINGLE PRODUCING FORMATIONS RECLAMATION OF WEl.L SITE OTHER.

0 CONVERT WELL TYPE 0 RECOMPLETE· DIFFERENT FORMATION

t2 DESCRIBE PROPOSED OR COMPLETED OPERATIONS. Clearly show all pertinent details including dates, depths, volumes, etc.

This sundry is serve as notification of the formal corporate name change of Newfield Production Company to Ovintiv Production Inc. Attached is a list of all wells wells that will be operated under Ovintiv Production Inc effective January 24, 2020.

PREVIOUS NAME: Newfield Producion Company 4 Waterway Square Place Suite 100 The Woodlands, TX 77380 (435)646-4825

(This space 1M State us. only)

(tiI2000)

NEW NAME: Ovintiv Production Inc. 4 Waterway Square Place Suite 100 The Woodlands, TX 77380 (435)646-4825

TITLE Regulatory Manager, Rockies

DArE 3/16/2020