For technical questions, please contact AmRad at 1.800.445.6033or www.amradmanufacturing.com
Turbo Easy-Start CAPACITANCE (MFD)
RANGE REQUIRED
108 to 130 mfds
JUMPER WIREREQUIRED
NONE
[Shown connected to a Turbo®200 which has been wired to provide 50mfd for the herm (compressor) and a 7.5mfd fan value].
FAN
Compressor
Common
50mfd
7.5mfd
Turbo Easy-Start Standard Dual-ValueMotor-Run Capacitor
Turbo®200 Universal Motor-Run
Capacitor
50
(C)
(Herm)
(F)
Jumper Wires
Standard Single-ValueMotor-Run Capacitor
2.5(3.0)
50mfd
10
[Typical Commercial Refrigeration Application]
[Typical Air Conditioning Application]
[Typical Air Conditioning Application]
Turbo Easy-Start
Turbo Easy-Start
EX
AM
PL
E 1
EX
AM
PL
E 2
EX
AM
PL
E 3
[Shown connected to a 50+7.5mfd dual-value capacitor].
[Shown connected to a 50mfd single-value capacitor].
P.R.
5
5
50P.R. 20
25
50P.R.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE TURBO®200 MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
JumperWire
Turbo Easy-Start CONNECTED TO STANDARD DUAL-VALUE MOTOR-RUN CAPACITORStep 1: No jumper wires required.Step 2: Connect the black wire (common) from Turbo Easy-Start to the COMMON (C) termi-nal of the standard dual-value motor-run capacitor as shown. Step 3: Connect the white wire from the Easy-Start to the HERM terminal of the standard dual-value motor-run capacitor as shown.
Turbo Easy-Start CONNECTED TO A TURBO®200 UNIVERSAL CAPACITORStep 1: No jumper wires required (on the Easy-Start).Step 2: Connect the black wire (common) from the Easy-Start to the COMMON (C) terminal of the Turbo®200 Universal Capacitor as shown. Step 3: Connect the white wire from the Easy-Start to the 20MFD terminal of the Turbo®200 Universal capacitor as shown.
Turbo Easy-Start CONNECTED TO A STANDARD SINGLE-VALUE MOTOR-RUN CAPACITORStep 1: No jumper wires required (on the Easy-Start).Step 2: Connect the black wire (common) from the Easy-Start to one of the terminals of the standard single value motor-run capacitor as shown. Step 3: Connect the white wire from the Easy-Start to the other terminal of the standard single value motor-run capacitor as shown.
UP
TO
1 T
ON
TURBO EASY-START CAPACITANCE (MFD)
RANGE REQUIRED
189 to 227 mfds
JUMPER WIREREQUIRED
Green Jumper Wire
[The Turbo Easy-Start is shown connected to a Turbo®200 which has been wired to provide 60mfd for the herm (compressor) and a 7.5mfd fan value].
FAN
Compressor
Common
60mfd
7.5mfd
Turbo Easy-Start Standard Dual-ValueMotor-Run Capacitor
Turbo®200 Universal Motor-Run
Capacitor
(C)
(Herm)
(F)
Jumper Wires
Standard Single-ValueMotor-Run Capacitor
2.5(3.0)
60mfd
[Typical Commercial Refrigeration Application]
[Typical Air Conditioning Application]
[Typical Air Conditioning Application]
Turbo Easy-Start
Turbo Easy-Start
EX
AM
PL
E 1
EX
AM
PL
E 2
EX
AM
PL
E 3
[Shown connected to a 60+7.5mfd dual-value capacitor].
[Shown connected to a 60mfd single-value capacitor].
50
50
5
5
50
10
25
20
P.R.
P.R.
P.R.
RANG
E 189M
FD-227
MFD
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE TURBO®200 MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.Jumper Wire
Jumper Wire
Jumper Wire
JumperWire
Turbo Easy-Start CONNECTED TO STANDARD DUAL-VALUE MOTOR-RUN CAPACITORStep 1: Using the green jumper wire, connect the purple and yellow terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the standard dual-value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the HERM terminal of the standard dual-val-ue motor-run capacitor as shown.
Turbo Easy-Start CONNECTED TO A TURBO®200 UNIVERSAL CAPACITORStep 1: Using the green jumper wire, connect the purple and yellow terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the Turbo®200 Universal Capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the 20MFD terminal of the Turbo®200 Univer-sal capacitor as shown.
Turbo Easy-Start CONNECTED TO A STANDARD SINGLE-VALUE MOTOR-RUN CAPACITORStep 1: Using the green jumper wire, connect the purple and yellow terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to one of the terminals of the standard single value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the other terminal of the standard single value motor-run capacitor as shown.
1 TO
2 T
ON
STURBO EASY-START CAPACITANCE (MFD)
RANGE REQUIRED
233 to 280 mfds
JUMPER WIREREQUIRED
Red Jumper Wire
FAN
Compressor
Common
80mfd
10mfd
Turbo Easy-Start Standard Dual-ValueMotor-Run Capacitor
Turbo®200X Universal Motor-Run
Capacitor
(C)
(Herm)
(F)
Standard Single-ValueMotor-Run Capacitor
80mfd
[Typical Commercial Refrigeration Application]
[Typical Air Conditioning Application]
[Typical Air Conditioning Application]
Turbo Easy-Start
Turbo Easy-Start
EX
AM
PL
E 1
EX
AM
PL
E 2
EX
AM
PL
E 3
[Shown connected to a 80+10mfd dual-value capacitor].
[Shown connected to a 80mfd single-value capacitor].
20
107.5
50P.R.
50
50
P.R.
50
P.R.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE TURBO®200X MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
[The Turbo Easy-Start 5 is shown connected to a Turbo®200X which has been wired to provide 80mfd for the herm (compressor) and a 10mfd fan value].
Jumper Wire
Jumper Wire
Jumper Wire
JumperWire
JumperWires
5
5
Turbo Easy-Start CONNECTED TO STANDARD DUAL-VALUE MOTOR-RUN CAPACITORStep 1: Using the red jumper wire, connect the purple, yellow and red terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the standard dual-value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the HERM terminal of the standard dual-val-ue motor-run capacitor as shown.
Turbo Easy-Start CONNECTED TO A TURBO®200 UNIVERSAL CAPACITORStep 1: Using the red jumper wire, connect the purple, yellow and red terminals to the correspond-ing colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the Turbo®200X Universal Capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the 50MFD terminal of the Turbo®200X Universal capactor as shown.
Turbo Easy-Start CONNECTED TO A STANDARD SINGLE-VALUE MOTOR-RUN CAPACITORStep 1: Using the red jumper wire, connect the purple, yellow and red terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to one of the terminals of the standard single value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the other terminal of the standard single value motor-run capacitor as shown.
2.5
TO 3
TO
NS
3.5
TO 5
TO
NS
TURBO EASY-START CAPACITANCE (MFD)
RANGE REQUIRED
270 to 324 mfds
JUMPER WIREREQUIRED
Yellow Jumper Wire
FAN
Compressor
Common
55mfd
10mfd
Turbo Easy-Start Standard Dual-ValueMotor-Run Capacitor
Turbo®200 Universal Motor-Run
Capacitor
(C)
(Herm)
(F)
JumperWires
Standard Single-ValueMotor-Run Capacitor
2.5(3.0)
55mfd
[Typical Commercial Refrigeration Application]
[Typical Air Conditioning Application]
[Typical Air Conditioning Application]
Turbo Easy-Start
Turbo Easy-Start
EX
AM
PL
E 1
EX
AM
PL
E 2
EX
AM
PL
E 3
[Shown connected to a 55+10mfd dual-value capacitor].
[Shown connected to a 55mfd single-value capacitor].
5
5
10
25
50
50
50
P.R. 20
P.R.
RANG
E 270M
FD-32
40MFD
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
NOTE: THE WIRES FROM THE COMPRESSOR AND THE FAN TO THE TURBO®200 MOTOR-RUN CAPACITOR ARE NOT SHOWN IN THIS ILLUSTRATION.
[The Turbo Easy-Start is shown connected to a Turbo®200 which has been wired to provide 55mfd for the herm (compressor) and a 10mfd fan value].
Jumper Wire
Jumper Wire
Jumper Wire
JumperWire
P.R.
Turbo Easy-Start CONNECTED TO STANDARD DUAL-VALUE MOTOR-RUN CAPACITORStep 1: Using the yellow jumper wire, connect the purple, yellow, red and brown terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the standard dual-value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the HERM terminal of the standard dual-val-ue motor-run capacitor as shown.
Turbo Easy-Start CONNECTED TO A TURBO®200 UNIVERSAL CAPACITORStep 1: Using the yellow jumper wire, connect the purple, yellow, red and brown terminals to the corre-sponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to the COMMON (C) terminal of the Turbo®200 Universal Capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the 20MFD terminal of the Turbo®200 Universal capacitor as shown.
Turbo Easy-Start CONNECTED TO A STANDARD SINGLE-VALUE MOTOR-RUN CAPACITORStep 1: Using the yellow jumper wire, connect the purple, yellow, red and brown terminals to the corresponding colored terminals on the Easy-Start as shown.Step 2: Connect the black wire (common) from the Turbo Easy-Start to one of the terminals of the standard single value motor-run capacitor as shown. Step 3: Connect the white wire from the Turbo Easy-Start to the other terminal of the standard single value motor-run capacitor as shown.
AM
RA
D’S
UN
IVER
SAL
TUR
BO
EA
SY-S
TAR
T W
IRIN
G IN
STR
UC
TIO
NS
IMP
OR
TAN
T N
OTE
: IF
THE
EXIS
TIN
G M
OTO
R-R
UN
CA
PAC
ITO
R H
AS
RU
STED
TER
MIN
ALS
,
IT S
HO
ULD
BE
REP
LAC
ED P
RIO
R T
O IN
STA
LLIN
G T
HE
TUR
BO
EA
SY-S
TAR
T.