fluorat – 02 analyzers
DESCRIPTION
FLUORAT – 02 ANALYZERS. FAMILY OF FLOUROMETERS. FLUORAT – 02 ANALYZERS. SERIES OF FLOUROMETERS. SINCE 1991. CERTIFICATION. VERSUS COMPETITORS. nonvolatile memory comfortable user interface wide variety of methods powerful flash xenon lamp (UV) - PowerPoint PPT PresentationTRANSCRIPT
FLUORAT – 02 ANALYZERSFLUORAT – 02 ANALYZERS
FAMILY OF FLOUROMETERSFAMILY OF FLOUROMETERS
FLUORAT – 02 ANALYZERSFLUORAT – 02 ANALYZERS
CERTIFICATIONCERTIFICATION
SINCE 1991SINCE 1991
SERIES OF FLOUROMETERSSERIES OF FLOUROMETERS
VERSUS COMPETITORS . . .VERSUS COMPETITORS . . .
nonvolatile memory
comfortable user interface
wide variety of methods
powerful flash xenon lamp (UV)
phosphorescence, chemiluminescence, and cryoluminescence modes
modulated background light correction
variety of attachments
FLUOROMETRY AND PHOTOMETRY FLUOROMETRY AND PHOTOMETRY AT ONCEAT ONCE
1 - light source2,7 - lens3 - excitation filter КВ4,10 - beam splitter5,9,12 - photodetector6 - cell8 - emission filter11 - focusing mirror
METHODSMETHODS
Method Parameter of interest
Fluorometry Oil, surfactants, phenols, nitrites, fluorides, sulphides, B, Al, Fe, Cu, Sn, Zn and other analytes
Phosphorescence Uranium
Photometry COD, nickel, vanadium, manganese, molybdenum, chromium (VI), cyanides
Nephelometry turbidity
Cryoluminescence lead, benzo[a]pyrene
HPLC PAHs, aflatoxins, vitamines A, E and others
FLUORAT-02 FAMILYFLUORAT-02 FAMILY
FLUORAT - 02-3МFLUORAT- 02-2М
FLUORAT - 02-2М with CRYO-1 attachment
FLUORAT - 02-PANORAMASpectrofluorometer
FLUORAT-02 FAMILYFLUORAT-02 FAMILY
LIQUID CHROMATOGROPH LIQUID CHROMATOGROPH LUMACHROMLUMACHROM
FLUORAT-02 FAMILYFLUORAT-02 FAMILY
Biochemical analyzers FLUORAT – 02 – ABFF, ABLF
Medical analyzerPhotometer ABF-100
CLINICAL DIAGNOSTICSCLINICAL DIAGNOSTICS
FLUORAT-02 FAMILYFLUORAT-02 FAMILY
AUTOMATIC FLOW ANALYZERSAUTOMATIC FLOW ANALYZERS
FLUORAT–AE-2 (in-line automatic monitoring of the content of petrol hydrocarbons in water)
FLOURAT-AA-2 (in-line automatic monitoring of the content of aluminum in water)
FLOURAT-AC-2 (in-line automatic monitoring of the content of active unbonded chlorine in water)
APPLICATION FIELDSAPPLICATION FIELDS
vitamines A, E, B1, B2, C mycotoxines B1, B2, G1, G2 PAHs heavy metals
Food
Environment and sanitary
water air emissions soil toxicity Geology и oil exploration
luminescent label method
Industry
oils in cryoproducts
Biochemistry and medicine
hemotest clinical diagnostics
WATER QUALITY MONITORINGWATER QUALITY MONITORING
Drinking water
Fl- 3М31.0 - 100 ЕМFTurbidity
Fl-2М,-3М5 -10 0.1 – 2.5Fluorides
Fl-2М,-3М10 -1000.0001 – 0.005Selenium
Fl-2М,-3М +CSC
200.02 – 0.5 Chromium
Fl-2М,-3М500.0001 – 0.05Beryllium
Fl-2М,-3М10 -1000.005 – 2.0Arsenic
ModelSample volume, cm3
Detection limit,
mg/dm3
Analyte
Abbreviations at “Model” column:Fl-2М — FLUORAT-02-2М, Fl-3М — FLUORAT-02-3МCSC – exchangeable sample compartmentCSCV – exchangeable sample compartment for vials
WATER QUALITY MONITORINGWATER QUALITY MONITORING
Natural, drinking and waste water
Analyte Detection limit,
mg/dm3
Sample volume, cm3
Model
Aluminium 0.01 – 5.0 10 Fl-2М,-3М
Anionic surfactants 0.025 – 2.0 5-20 Fl-2М,-3М
Benzo[a]pyrene 0.000002 – 0.0002 1000 Fl-2М +CRYO1
Boron 0.05 – 5 5 Fl-2М,-3М
Vanadium 0.025 – 2.0 50-500 Fl-2М,-3М
Total iron 0.05 – 5.0 1-10 Fl-2М,-3М
Cationic surfactants 0.01 – 2 5-20 Fl-2М,-3М
WATER QUALITY MONITORINGWATER QUALITY MONITORING
Natural, drinking and waste water
Analyte Detection limit,
mg/dm3
Sample volume, cm3
Model
Manganese 0.01 – 2.5 20-100 Fl-2М,-3М +CSC
Copper 0.005 – 0.2 2 Fl-2М,-3М
Molybdenum 0.025 – 0.25 10-100 Fl-2М,-3М
Oil products 0.005 – 50 100 Fl-2М,-3М
Nickel 0.01 – 4 5-100 Fl-2М,-3М +CSC
Nitrites 0.005 – 5.0 5 Fl-2М,-3М
WATER QUALITY MONITORINGWATER QUALITY MONITORING
Natural, drinking and waste water
Analyte Detection limit,
mg/dm3
Sample volume, cm3
Model
Tin 0.01 – 1.0 5 – 25 Fl-2М,-3М
Lead 0.005 – 1.0 10 Fl-2М +CRYO2(1)
Sulphides 0.005 – 2.5 50 Fl-2М,-3М
Uranium 0.002 – 1.0 0,5 Fl-2М
Phenols 0.0005 – 25.0 10 – 250 Fl-2М,-3М
Formaldehyde 0.02 – 0.5 2 Fl-2М,-3М
COD 5 – 10000 2 – 4Fl-2М,-3М+CSCV + COD-reactor
Cyanides 0.02 – 0.4 5 – 20 Fl-2М,-3М +CSC
Zinc 0.005 – 2.0 5 – 50 Fl-2М,-3М
OCCUPATIONAL AND COMMUNITYOCCUPATIONAL AND COMMUNITY AIRAIR
Analyte Detection limit, mg/m3 Samples volume, dm3 Model
community occupational community occupational
Benz[a]pyrene (HPLC) 0.0005 – 0.1 mkg/m3
0.02 – 5000 mkg/m3
5000 150 -300 Fl-2М + Lumachtom
Benz[a]pyrene (CRIO) 0.0005 – 0.1 mkg/m3
0.07 – 5000 mkg/m3
5000 500 - 800 Fl-2М + CRYO-1
Formaldehyde 0.01 – 0.25 0.04-1 4 – 5 1–1.5 Fl-2М,-3М
Phenols 0.004 – 0.2 0.1 – 5 50 -60 2-2.5 Fl-2М,-3М
Copper 0.001-0.1 0.2-2.0 1000 50 Fl-2М,-3М
Cadmium 0.00025-0.005 0.01-2.0 2000 50 Fl-2М,-3М
Lead 0.00025-0.01 0.0025-0.1 500 50 Fl-2М+ CRYO2(1)
Hydrogen sulphide 0.002-0.08 0.5-4.0 50 1 Fl-2М,-3М
Hydrogen fluoride - 0.2-5 - 10 – 15 Fl-2М,-3М
Zinc 0.001-0.1 0.2 – 2.0 1000 50 Fl-2М,-3М
FOOD ANALYSESFOOD ANALYSES
Analyte Detection limit, mg/kg
Sample mass
(volume), g
Vitamin В1 0.1 – 10 10
Vitamin В2 0.05 – 10 10
Vitamin С 10 – 5000 1 - 25
Tin 0.5 – 8.0 0.5 –1.0
Selenium 0.1 - 100 0.1
EMISSION MEASUREMENTEMISSION MEASUREMENT
Analyte Detection limit, mg/m3
Samples volume, dm3
Model
Benz[a]pyrene (CRIO)
0.07 – 1000 mkg/m3
200 - 400 Fl-2М +CRYO1
Phenol 0.1 – 50 2 – 2.5 Fl-2М,-3М
Formaldehyde 0.04 – 40 4 – 10 Fl-2М,-3М
Benz[a]pyrene (HPLC)
0.015 – 5000
mkg/m3
200 – 400 Fl-2М +Lumachrom
SOIL, BOTTOM SEDIMENTSSOIL, BOTTOM SEDIMENTS
Analyte Detection limit,
mg/kg
Sample mass
(volume), g
Model
Oil products 5 - 20000 0.2 –1.0 Fl-2М,-3М
Boron 0.5 - 50 5 Fl-2М,-3М
Zinc 0.5 - 20 5 Fl-2М,-3М
Benz[a]pyrene (HPLC) 0.005 – 2 1 Fl-2М + Lumachrom
OTHER APPLICATIONSOTHER APPLICATIONS
Analyte Detection limit,
mg/dm3
Samples volume,
cm3
Model Sample type
Silicon 0.005 - 0.06 10 Fl-2М,-3М Power plant
feedwater
Fluorescein 0.001- 5,0 20 Fl-2М,-3М Stratal water and borehole water
Coal oils 5 – 100
0.0125 - 0,8 mg
Fl-2М,-3М Cryoproducts
Selenium 0,1 – 100 mg/kg
100 mg Fl-2М,-3М + Minotavr-1
Feed mixes
SPECIFICATIONSPECIFICATION
FluoratFluorat®®-02-2M-02-2M FluoratFluorat®®-02-3M-02-3M
Spectral range 200 - 670 200 – 900
Cell, mm 10, 20 and 40
Sample volume (for 10 mm cell), cm3
3
Measurement time, sec < 16
Power supply 100-240 VAC, 50/60 Hz, 12VDC, 3 A
Power comsumption, W < 36
Size, mm 300x300x120 300x300x95
Weight 8 8
CONCLUSIONCONCLUSION
Lumex filter-based fluorometers Fluorat-02-2M and Fluorat-02-3M possess the most advanced technical characteristics as compared to other instruments in this category
FLUORATFLUORAT - - 02-3М02-3МFLUORATFLUORAT-- 02-02-22ММ
CONTACTSCONTACTS
LUMEX LTD.LUMEX LTD.
19, Moskovskiy pr., St. Petersburg, 190005 RussiaPhone: +7 (812) 718-5390, +7 (812) 718-5391Fax: +7 (812) 316-6538E-mail: [email protected], [email protected]; http://www.lumex.ru
LUMEX INTERNATIONALLUMEX INTERNATIONAL
4736 Lee Hwy, suite 203, Arlington VA 22207, USAPhone/Fax: +1 (703) 243-7103;E-mail: [email protected]; http://www.lumexint.com
OhioLumex Co.OhioLumex Co.
9263, Ravenna Rd., Unit A3 Twinsburg, OH 44087 USAPhone: +1 (888) 876-2611; +1 (330) 405-0837Fax: +1 (330) 405-0847E-mail: [email protected], [email protected]; http://www.ohiolumex.com