fluorat- 02 - panorama spectrofluorometer fluorat- 02 - panorama spectrofluorometer certification...
TRANSCRIPT
FLUORAT- 02 - PANORAMA FLUORAT- 02 - PANORAMA SPECTROFLUOROMETERSPECTROFLUOROMETER
CERTIFICATIONCERTIFICATION
SINCE 1996SINCE 1996
ANALITICAL METHODSANALITICAL METHODS
Methods
Luminescent analysis • liquid sample; • glass;• paper; • powder; • fabric
Photometric analysis • liquid sample;
• small (10 x 10 mm) or large
(60 x 60 mm) size glass
Time-resolved analysis of luminescent kinetics
• all kinds of above listed samples
ADVANTAGEADVANTAGESS
Xe-flash lamp (1 μs on half-width)– ultra high intensity in hard UV-range (210 nm)– time-resolved luminescent kinetics
measurements (step = 50 ns)– very low power consumption (40 W)
Optical scheme with a good correlation between fluo-channel and reference and photometric channels
Broad set of FFOS-attachments
Uniform design for 2 main applications– scientific spectrofluorimeter– HPLC-detector
MAIN APPLICATIONSMAIN APPLICATIONS
Scientific and Medical Researches
Environmental Monitoring
Determination of water oil pollutersConcentration of oil in water
measurementBioproduction study of nature water
reservoirs by chlorophyll level
Optimization of determination conditions for analytical techniques
Studies of luminescent substances and label methods
Technological Quality ControlGroundwater survey by fluorescent
label methodPurity test for silicon plates after
cuttingQuality of luminophores
Forensic investigations
Fires reasons determination
Identification of luminescent marks on securities
TECHNTECHNIQUEIQUESS
Object Samples
Natural, potable and waste water
Nitrite, oil, phenols, fluoride, formaldehyde, benz[a]pyrene, surfactants, Al, Be, Se, Cu, Fe, B, Zn, Pb, Sn, As, Mo, V
Air in production areas and atmospheric air in residential quarters
Phenols, formaldehyde, cadmium, copper, zinc
Industrial emission Phenols, lead, formaldehyde, benz[a]pyrene
Foodstuff Vitamines B1, B2, С, zinc, tin
Soil Oil, boron, zinc
Petrol Lead
SOFTWARESOFTWARE
ChromatographyChromatography
1 Fluorene
2 Phenantrene
3 Antracene
4 Fluorantene
5 Pyrene
6 Chrysene
7 Benz[b]fluorantene
8 Benz[k]fluorantene
Separation of PAHs in a
snow sample
ATTACHMENTSATTACHMENTS
FLUORAT-02-Panorama is used as a detector for gradient HPLC-system
HPLC-4 with 2 syringe pumps Python
ATTACHMENTSATTACHMENTS
“Hobby”
“Microscan”
Photometric measurement outside the cell-compartment
Luminescent measurement outside the cell-compartment
“Frog”
Automated measurement
on standard plates
ATTACHMENTSATTACHMENTS
Investigation of the samples under
liquid nitrogen temperature:
“Cryo-1” – studying the narrow band
Schpolsky spectra of PAHs
(benz[a]pyrene)“Cryo-2” – determination of the toxic metals,
e.g. Pb, Bi, Sn and others
SPECIFICATIONSSPECIFICATIONS
Spectral Range 210 – 690 nm (210 – 840)
Slit width 6 – 8 nm (12 – 15 for HPLC-detector)
Wavelength accuracy ± 1 nm
Pulse repetition rate 25 Hz
S/N ratio for Raman scattering of H2O
150:1 (for 6 – 8 nm slit)
300:1 (for 12 – 15 nm slit)
Power requirements 110 – 240V, 40VA
Dimensions 400 x 350 x 160 mm
Weight 17 kg
CONCLUSIONCONCLUSION
LUMEX spectrofluorometer Panorama has a good chance in competition with others instruments
But we are standing now in front of a very interesting and not so easy job –
Creating a new family of spectrofluorometric analyzers:
Detector for HPLC
Scientific spectrofluorimeter
CONTACTSCONTACTS
LUMEX LTD.LUMEX LTD.
19, Moskovskiy pr., St. Petersburg, 190005 RussiaPhone: +7 (812) 718-5390, +7 (812) 718-5391Fax: +7 (812) 316-6538E-mail: [email protected], [email protected]; http://www.lumex.ru
LUMEX INTERNATIONALLUMEX INTERNATIONAL
4736 Lee Hwy, suite 203, Arlington VA 22207, USAPhone/Fax: +1 (703) 243-7103;E-mail: [email protected]; http://www.lumexint.com
OhioLumex Co.OhioLumex Co.
9263, Ravenna Rd., Unit A3 Twinsburg, OH 44087 USAPhone: +1 (888) 876-2611; +1 (330) 405-0837Fax: +1 (330) 405-0847E-mail: [email protected], [email protected]; http://www.ohiolumex.com